Description Value
Form FactorRack-mount
Product Processor Socket Count4
Single ServerNo
Resilient SystemNo
Error Correcting CodeYes
Error Correcting Code Enabled in Hardware as ShippedYes
Available Expansion Slots12
Operating Systems SupportedWindows,Linux,Other
Operating System Used for TestingWindows
Power Saving Features AvailableVariable speed fan control based on power or thermal readings,Processor or core reduced power states,Low power I/O states,Power capping,Low power memory states,Dynamic voltage and frequency scaling of processor(s)
Power Saving Features EnabledVariable speed fan control based on power or thermal readings,Processor or core reduced power states,Low power I/O states,Power capping,Low power memory states,Dynamic voltage and frequency scaling of processor(s)
End User Required Power Saving FeaturesN/A
Storage Power Management Enabled in Hardware on ShipmentYes
Memory Power Management Enabled in Hardware on ShipmentYes
I/O Power Management Enabled in Hardware on ShipmentYes
Processor Dynamic Voltage Scaling Enabled on ShipmentYes
Processor Dynamic Frequency Scaling Enabled on ShipmentNo
Processor Dynamic Voltage Scaling End-User Enabling RequiredNo
Processor Dynamic Frequency Scaling End-User Enabling RequiredNo
Processor or Core Reduced Power States Enabled on ShipmentNo
Processor or Core Reduced Power States Enabling RequiredNo
Power Capping Enabled on ShipmentNo
Power Capping End-User Enabling RequiredNo
Variable Speed Fan Control Enabled on ShipmentYes
Variable Speed Fan Control End-User Enabling RequiredNo
Low Power Memory States Enabled on ShipmentYes
Low Power Memory States End-User Enabling RequiredNo
Low Power I/O States Enabled on ShipmentYes
Liquid Cooling Capability Enabled on ShipmentNo
Liquid Cooling Capability End-User Enabling RequiredNo
Available DIMM Slots48
Maximum Memory Capacity (GB)6000
SERT Version Other
SERT Version Other  2.0.2
Model Number or Config ID for Low-end Performance ConfigurationUCSC-C480-M5 (LP)
Model Number or Config ID for Typical or Single ConfigurationUCSC-C480-M5 (TP)
Model Number or Config ID for High-end Performance ConfigurationUCSC-C480-M5 (HP)
Installed Processors for Low-end Performance Configuration2
Installed Processors for Typical or Single Configuration4
Installed Processors for High-end Performance Configuration4
Cores Per Processor Low-end Performance Configuration10
Cores Per Processor Typical or Single Configuration4
Cores Per Processor High-end Performance Configuration28
Number of Threads for Low-end Performance Configuration40
Number of Threads for Typical or Single Configuration80
Number of Threads for High-end Performance Configuration112
Processor Brand Low-end Performance ConfigurationIntel
Processor Brand Typical or Single ConfigurationIntel
Processor Brand High-end Performance ConfigurationIntel
Processor Model Name Low-end Performance ConfigurationIntel(R) Xeon(R) Gold 5115 CPU @ 2.40GH
Processor Model Name Typical or Single ConfigurationIntel(R) Xeon(R) Gold 6248 CPU @ 2.50GH
Processor Model Name High-end Performance ConfigurationIntel(R) Xeon(R) Platinum 8280 CPU
Processor Speed for Low-end Performance Configuration (GHz)2.4
Processor Speed for Typical or Single Configuration (GHz)2.5
Processor Speed for High-end Performance Configuration (GHz)2.7
Num. of DDR Channels for Low-end Performance Configuration24
Num. of DDR Channels for Typical or Single Configuration24
Num. of DDR Channels for High-end Performance Configuration48
Memory Manufacturer for Low-end Performance ConfigurationSamsung
Memory Manufacturer for Typical or Single ConfigurationSamsung
Memory Manufacturer for High-end Performance ConfigurationSamsung
Memory Model Number Low-end Performance Configuration16GB DDR4-2666-MHz RDIMM/2Rx4/1.2v;
Memory Model Number Typical or Single Configuration32GB DDR4-2933-MHz RDIMM/2Rx4/1.2v;
Memory Model Number High-end Performance Configuration64GB DDR4-2933-MHz RDIMM/2Rx4/1.2v
Memory Speed Low-end Performance Configuration (GHz)2.66
Memory Speed Typical or Single Configuration (GHz)2.93
Memory Speed High-end Performance Configuration (GHz)2.93
Low-end Performance Configuration Size Per DIMM (GB)16
Typical or Single Configuration Size Per DIMM (GB)32
High-end Performance Configuration Size Per DIMM (GB)64
Installed Num. DIMMs for Low-end Performance Configuration24
Installed Num. DIMMs for Typical or Single Configuration24
Installed Num. DIMMs for High-end Performance Configuration48
Installed Memory for Low-end Performance Configuration (GB)384
Installed Memory for Typical or Single Configuration (GB)768
Installed Memory for High-end Performance Configuration (GB)3072
Num. Solid State Drives (SSDs) Low-end Performance Configuration2
Num. Solid State Drives (SSDs) Typical or Single Configuration8
Num. Solid State Drives (SSDs) High-end Performance Configuration2
Number Rotational Drives Low-end Performance Configuration0
Number Rotational Drives Typical or Single Configuration0
Number Rotational Drives High-end Performance Configuration0
Low-end Performance Configuration Redundant Power SupplyYes
Typical or Single Configuration Redundant Power SupplyYes
High-end Performance Configuration Redundant Power SupplyYes
Power Supply Type for Low-end Performance ConfigurationSingle-Output
Power Supply Type for Typical or Single ConfigurationSingle-Output
Power Supply Type for High-end Performance ConfigurationSingle-Output
Power Supply Manufacturer Low-end Performance ConfigurationCisco Systems, Inc.
Power Supply Manufacturer Typical or Single ConfigurationCisco Systems Inc.
Power Supply Manufacturer High-end Performance ConfigurationCisco Systems Inc.
Power Supply Model Name Low-end Performance ConfigurationCIS-S-1600ADE00
Power Supply Model Name Typical or Single ConfigurationCIS-S-1600ADE00
Power Supply Model Name High-end Performance ConfigurationCIS-S-1600ADE00
Power Supply Model Number Low-end Performance ConfigurationCIS-S-1600ADE00
Power Supply Model Number Typical or Single ConfigurationCIS-S-1600ADE00
Power Supply Model Number High-end Performance ConfigurationCIS-S-1600ADE00
Power Supply Rated Output Low-end Performance Configuration (W)161
Power Supply Rated Output Typical or Single Configuration (W)806
Power Supply Rated Output High-end Performance Configuration (W)1614
Num. Power Supplies for Low-end Performance Configuration4
Num. Power Supplies for Typical or Single Configuration4
Num. Power Supplies for High-end Performance Configuration4
Number of PSU for Redundancy Low-end Performance Configuration4
Number of PSU for Redundancy Typical or Single Configuration4
Number of PSU for Redundancy High-end Performance Configuration4
64-bit Architecture64-bit supported
SERT Compress Eff. Score for Low-end Performance Configuration10.89
SERT Compress Eff. Score for Typical or Single Configuration15.27
SERT Compress Eff. Score for High-end Performance Configuration16.95
SERT CryptoAES Efficiency Score Low-end Performance Configuration16.74
SERT CryptoAES Efficiency Score Typical or Single Configuration23.02
SERT CryptoAES Efficiency Score High-end Performance Configuration20.42
SERT LU Efficiency Score Low-end Performance Configuration15.41
SERT LU Efficiency Score Typical or Single Configuration21.94
SERT LU Efficiency Score High-end Performance Configuration24.85
SERT SOR Efficiency Score Typical or Single Configuration12.56
SERT SOR Efficiency Score High-end Performance Configuration14.26
SERT SORT Efficiency Score Low-end Performance Configuration8.9
SERT SORT Efficiency Score Typical or Single Configuration13.76
SERT SORT Efficiency Score High-end Performance Configuration15.16
SERT SHA256 Efficiency Score Low-end Performance Configuration13.35
SERT SHA256 Efficiency Score Typical or Single Configuration20.34
SERT SHA256 Efficiency Score High-end Performance Configuration23.24
SERT Flood Efficiency Score Low-end Performance Configuration3.2
SERT Flood Efficiency Score Typical or Single Configuration2.25
SERT Flood Efficiency Score High-end Performance Configuration0.97
SERT Capacity Efficiency Score Low-end Performance Configuration23.58
SERT Capacity Efficiency Score Typical or Single Configuration32.3
SERT Capacity Efficiency Score High-end Performance Configuration32.65
SERT Sequential Efficiency Score Low-end Performance Configuration20.47
SERT Sequential Efficiency Score Typical or Single Configuration15.51
SERT Sequential Efficiency Score High-end Performance Configuration12.5
SERT Random Efficiency Score Low-end Performance Configuration194.5
SERT Random Efficiency Score Typical or Single Configuration157.22
SERT Random Efficiency Score High-end Performance Configuration124.22
SERT SSJ Efficiency Score Low-end Performance Configuration10.11
SERT SSJ Efficiency Score Typical or Single Configuration13.17
SERT SSJ Efficiency Score High-end Performance Configuration13.99
SERT Idle Measurement (Watts) Low-end Performance Configuration238.1
SERT Active State Efficiency Score Low-end Performance Configuration21
SERT Total Server Normalized Performance Score Low-end Performance Configuration18.15
SERT Total Server Power Score  (Watts) Low-end Performance Configuration564.90
SERT Idle Measurement (Watts) Typical or Single Configuration291.5
SERT Active State Efficiency Score Typical or Single Configuration29.1
SERT Total Server Normalized Performance Score Typical or Single Configuration33.58
SERT Total Server Power Score (Watts) Typical or Single Configuration817.67
SERT Idle Measurement (Watts) High-end Performance Configuration22.18
SERT Active State Efficiency Score High-end Performance Configuration186.19
SERT Total Server Normalized Performance Score High-end Performance Configuration20.47
SERT Total Server Power Score (Watts) High-end Performance Configuration194.5
Date Available On Market03/18/2018
Date Certified12/03/2019
MarketsUnited States, Taiwan, Japan, Canada
ENERGY STAR Model IdentifierES 0021829 UCSC-C480-M5 12062019025938 80025683
EnergyStar Provided Specifications
Description Value
Form FactorRack-mount
Product Processor Socket Count4
Single ServerNo
Resilient SystemNo
Error Correcting CodeYes
Error Correcting Code Enabled in Hardware as ShippedYes
Available Expansion Slots12
Operating Systems SupportedWindows,Linux,Other
Operating System Used for TestingWindows
Power Saving Features AvailableVariable speed fan control based on power or thermal readings,Processor or core reduced power states,Low power I/O states,Power capping,Low power memory states,Dynamic voltage and frequency scaling of processor(s)
Power Saving Features EnabledVariable speed fan control based on power or thermal readings,Processor or core reduced power states,Low power I/O states,Power capping,Low power memory states,Dynamic voltage and frequency scaling of processor(s)
End User Required Power Saving FeaturesN/A
Storage Power Management Enabled in Hardware on ShipmentYes
Memory Power Management Enabled in Hardware on ShipmentYes
I/O Power Management Enabled in Hardware on ShipmentYes
Processor Dynamic Voltage Scaling Enabled on ShipmentYes
Processor Dynamic Frequency Scaling Enabled on ShipmentNo
Processor Dynamic Voltage Scaling End-User Enabling RequiredNo
Processor Dynamic Frequency Scaling End-User Enabling RequiredNo
Processor or Core Reduced Power States Enabled on ShipmentNo
Processor or Core Reduced Power States Enabling RequiredNo
Power Capping Enabled on ShipmentNo
Power Capping End-User Enabling RequiredNo
Variable Speed Fan Control Enabled on ShipmentYes
Variable Speed Fan Control End-User Enabling RequiredNo
Low Power Memory States Enabled on ShipmentYes
Low Power Memory States End-User Enabling RequiredNo
Low Power I/O States Enabled on ShipmentYes
Liquid Cooling Capability Enabled on ShipmentNo
Liquid Cooling Capability End-User Enabling RequiredNo
Available DIMM Slots48
Maximum Memory Capacity (GB)6000
SERT Version Other
SERT Version Other  2.0.2
Model Number or Config ID for Low-end Performance ConfigurationUCSC-C480-M5 (LP)
Model Number or Config ID for Typical or Single ConfigurationUCSC-C480-M5 (TP)
Model Number or Config ID for High-end Performance ConfigurationUCSC-C480-M5 (HP)
Installed Processors for Low-end Performance Configuration2
Installed Processors for Typical or Single Configuration4
Installed Processors for High-end Performance Configuration4
Cores Per Processor Low-end Performance Configuration10
Cores Per Processor Typical or Single Configuration4
Cores Per Processor High-end Performance Configuration28
Number of Threads for Low-end Performance Configuration40
Number of Threads for Typical or Single Configuration80
Number of Threads for High-end Performance Configuration112
Processor Brand Low-end Performance ConfigurationIntel
Processor Brand Typical or Single ConfigurationIntel
Processor Brand High-end Performance ConfigurationIntel
Processor Model Name Low-end Performance ConfigurationIntel(R) Xeon(R) Gold 5115 CPU @ 2.40GH
Processor Model Name Typical or Single ConfigurationIntel(R) Xeon(R) Gold 6248 CPU @ 2.50GH
Processor Model Name High-end Performance ConfigurationIntel(R) Xeon(R) Platinum 8280 CPU
Processor Speed for Low-end Performance Configuration (GHz)2.4
Processor Speed for Typical or Single Configuration (GHz)2.5
Processor Speed for High-end Performance Configuration (GHz)2.7
Num. of DDR Channels for Low-end Performance Configuration24
Num. of DDR Channels for Typical or Single Configuration24
Num. of DDR Channels for High-end Performance Configuration48
Memory Manufacturer for Low-end Performance ConfigurationSamsung
Memory Manufacturer for Typical or Single ConfigurationSamsung
Memory Manufacturer for High-end Performance ConfigurationSamsung
Memory Model Number Low-end Performance Configuration16GB DDR4-2666-MHz RDIMM/2Rx4/1.2v;
Memory Model Number Typical or Single Configuration32GB DDR4-2933-MHz RDIMM/2Rx4/1.2v;
Memory Model Number High-end Performance Configuration64GB DDR4-2933-MHz RDIMM/2Rx4/1.2v
Memory Speed Low-end Performance Configuration (GHz)2.66
Memory Speed Typical or Single Configuration (GHz)2.93
Memory Speed High-end Performance Configuration (GHz)2.93
Low-end Performance Configuration Size Per DIMM (GB)16
Typical or Single Configuration Size Per DIMM (GB)32
High-end Performance Configuration Size Per DIMM (GB)64
Installed Num. DIMMs for Low-end Performance Configuration24
Installed Num. DIMMs for Typical or Single Configuration24
Installed Num. DIMMs for High-end Performance Configuration48
Installed Memory for Low-end Performance Configuration (GB)384
Installed Memory for Typical or Single Configuration (GB)768
Installed Memory for High-end Performance Configuration (GB)3072
Num. Solid State Drives (SSDs) Low-end Performance Configuration2
Num. Solid State Drives (SSDs) Typical or Single Configuration8
Num. Solid State Drives (SSDs) High-end Performance Configuration2
Number Rotational Drives Low-end Performance Configuration0
Number Rotational Drives Typical or Single Configuration0
Number Rotational Drives High-end Performance Configuration0
Low-end Performance Configuration Redundant Power SupplyYes
Typical or Single Configuration Redundant Power SupplyYes
High-end Performance Configuration Redundant Power SupplyYes
Power Supply Type for Low-end Performance ConfigurationSingle-Output
Power Supply Type for Typical or Single ConfigurationSingle-Output
Power Supply Type for High-end Performance ConfigurationSingle-Output
Power Supply Manufacturer Low-end Performance ConfigurationCisco Systems, Inc.
Power Supply Manufacturer Typical or Single ConfigurationCisco Systems Inc.
Power Supply Manufacturer High-end Performance ConfigurationCisco Systems Inc.
Power Supply Model Name Low-end Performance ConfigurationCIS-S-1600ADE00
Power Supply Model Name Typical or Single ConfigurationCIS-S-1600ADE00
Power Supply Model Name High-end Performance ConfigurationCIS-S-1600ADE00
Power Supply Model Number Low-end Performance ConfigurationCIS-S-1600ADE00
Power Supply Model Number Typical or Single ConfigurationCIS-S-1600ADE00
Power Supply Model Number High-end Performance ConfigurationCIS-S-1600ADE00
Power Supply Rated Output Low-end Performance Configuration (W)161
Power Supply Rated Output Typical or Single Configuration (W)806
Power Supply Rated Output High-end Performance Configuration (W)1614
Num. Power Supplies for Low-end Performance Configuration4
Num. Power Supplies for Typical or Single Configuration4
Num. Power Supplies for High-end Performance Configuration4
Number of PSU for Redundancy Low-end Performance Configuration4
Number of PSU for Redundancy Typical or Single Configuration4
Number of PSU for Redundancy High-end Performance Configuration4
64-bit Architecture64-bit supported
SERT Compress Eff. Score for Low-end Performance Configuration10.89
SERT Compress Eff. Score for Typical or Single Configuration15.27
SERT Compress Eff. Score for High-end Performance Configuration16.95
SERT CryptoAES Efficiency Score Low-end Performance Configuration16.74
SERT CryptoAES Efficiency Score Typical or Single Configuration23.02
SERT CryptoAES Efficiency Score High-end Performance Configuration20.42
SERT LU Efficiency Score Low-end Performance Configuration15.41
SERT LU Efficiency Score Typical or Single Configuration21.94
SERT LU Efficiency Score High-end Performance Configuration24.85
SERT SOR Efficiency Score Typical or Single Configuration12.56
SERT SOR Efficiency Score High-end Performance Configuration14.26
SERT SORT Efficiency Score Low-end Performance Configuration8.9
SERT SORT Efficiency Score Typical or Single Configuration13.76
SERT SORT Efficiency Score High-end Performance Configuration15.16
SERT SHA256 Efficiency Score Low-end Performance Configuration13.35
SERT SHA256 Efficiency Score Typical or Single Configuration20.34
SERT SHA256 Efficiency Score High-end Performance Configuration23.24
SERT Flood Efficiency Score Low-end Performance Configuration3.2
SERT Flood Efficiency Score Typical or Single Configuration2.25
SERT Flood Efficiency Score High-end Performance Configuration0.97
SERT Capacity Efficiency Score Low-end Performance Configuration23.58
SERT Capacity Efficiency Score Typical or Single Configuration32.3
SERT Capacity Efficiency Score High-end Performance Configuration32.65
SERT Sequential Efficiency Score Low-end Performance Configuration20.47
SERT Sequential Efficiency Score Typical or Single Configuration15.51
SERT Sequential Efficiency Score High-end Performance Configuration12.5
SERT Random Efficiency Score Low-end Performance Configuration194.5
SERT Random Efficiency Score Typical or Single Configuration157.22
SERT Random Efficiency Score High-end Performance Configuration124.22
SERT SSJ Efficiency Score Low-end Performance Configuration10.11
SERT SSJ Efficiency Score Typical or Single Configuration13.17
SERT SSJ Efficiency Score High-end Performance Configuration13.99
SERT Idle Measurement (Watts) Low-end Performance Configuration238.1
SERT Active State Efficiency Score Low-end Performance Configuration21
SERT Total Server Normalized Performance Score Low-end Performance Configuration18.15
SERT Total Server Power Score  (Watts) Low-end Performance Configuration564.90
SERT Idle Measurement (Watts) Typical or Single Configuration291.5
SERT Active State Efficiency Score Typical or Single Configuration29.1
SERT Total Server Normalized Performance Score Typical or Single Configuration33.58
SERT Total Server Power Score (Watts) Typical or Single Configuration817.67
SERT Idle Measurement (Watts) High-end Performance Configuration22.18
SERT Active State Efficiency Score High-end Performance Configuration186.19
SERT Total Server Normalized Performance Score High-end Performance Configuration20.47
SERT Total Server Power Score (Watts) High-end Performance Configuration194.5
Date Available On Market03/18/2018
Date Qualified12/03/2019
MarketsUnited States, Taiwan, Japan, Canada
ENERGY STAR Model IdentifierES 0021829 UCSC-C480-M5 12062019025938 80025683
EnergyStar Provided Specifications
Description Value
Type3 or 4 Socket Server (neither Blade nor Multi-node)
Form FactorRack-mount
Base Idle State Power Allowance Category for 1S and 2S ServersN/A
Single ServerNo
Resilient SystemNo
Managed ServerYes
Error Correcting CodeNo
Error Correcting Code Enabled in Hardware as ShippedNo
Available Expansion Slots2
Operating Systems SupportedWindows,Linux,Other
Operating System Used for TestingWindows
Power Saving Features AvailableVariable speed fan control based on power or thermal readings,Power capping,Low power memory states,Low power I/O states,Processor or core reduced power states,Dynamic voltage and frequency scaling of processor(s)
Power Saving Features EnabledVariable speed fan control based on power or thermal readings,Power capping,Low power memory states,Low power I/O states,Processor or core reduced power states,Dynamic voltage and frequency scaling of processor(s)
End User Required Power Saving FeaturesN/A
Storage Power Management Enabled in Hardware on ShipmentYes
Memory Power Management Enabled in Hardware on ShipmentYes
I/O Power Management Enabled in Hardware on ShipmentYes
Processor Dynamic Voltage Scaling Enabled on ShipmentYes
Processor Dynamic Frequency Scaling Enabled on ShipmentYes
Processor Dynamic Voltage Scaling End-User Enabling RequiredNo
Processor Dynamic Frequency Scaling End-User Enabling RequiredNo
Processor or Core Reduced Power States Enabled on ShipmentYes
Processor or Core Reduced Power States Enabling RequiredNo
Low Power Memory States Enabled on ShipmentYes
Low Power Memory States End-User Enabling RequiredNo
Low Power I/O States Enabled on ShipmentYes
Low Power I/O States End-User Enabling RequiredNo
Liquid Cooling Capability Enabled on ShipmentNo
Liquid Cooling Capability End-User Enabling RequiredNo
Available DIMM Slots48
Maximum Memory Capacity (GB)12000
Model Number or Config ID for Low-end Performance ConfigurationUCSC-C480-M5 (LE)
Model Number or Config ID for Minimum Power ConfigurationUCSC-C480-M5 (MP)
Model Number or Config ID for Typical or Single ConfigurationUCSC-C480-M5 (TC)
Model Number or Config ID for High-end Performance ConfigurationUCSC-C480-M5 (HE)
Installed Processors for Low-end Performance Configuration2
Installed Processors for Minimum Power Configuration2
Installed Processors for Typical or Single Configuration4
Installed Processors for High-end Performance Configuration4
Cores Per Processor Low-end Performance Configuration24
Cores Per Processor Minimum Power Configuration20
Cores Per Processor Typical or Single Configuration96
Cores Per Processor High-end Performance Configuration112
Number of Threads for Low-end Performance Configuration48
Number of Threads for Minimum Power Configuration40
Number of Threads for Typical or Single Configuration192
Number of Threads for High-end Performance Configuration224
Processor Brand Low-end Performance ConfigurationIntel
Processor Brand Minimum Power ConfigurationIntel
Processor Brand Typical or Single ConfigurationIntel
Processor Brand High-end Performance ConfigurationIntel
Processor Model Name Low-end Performance ConfigurationIntel(R) Xeon(R) Gold 5118 CPU @ 2.30GHz
Processor Model Name Minimum Power ConfigurationIntel(R) Xeon(R) Gold 5115 CPU @ 2.40GHz
Processor Model Name Typical or Single ConfigurationIntel(R) Xeon(R) Platinum 8160 CPU @ 2.10GHz
Processor Model Name High-end Performance ConfigurationIntel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz
Processor Speed for Low-end Performance Configuration (GHz)2.3
Processor Speed for Minimum Power Configuration (GHz)2.4
Processor Speed for Typical or Single Configuration (GHz)2.1
Processor Speed for High-end Performance Configuration (GHz)2.5
Num. of DDR Channels for Low-end Performance Configuration12
Num. of DDR Channels for Minimum Power Configuration2
Num. of DDR Channels for Typical or Single Configuration24
Num. of DDR Channels for High-end Performance Configuration48
Memory Speed Low-end Performance Configuration (GHz)2.67
Memory Speed Minimum Power Configuration (GHz)2.67
Memory Speed Typical or Single Configuration (GHz)2.67
Memory Speed High-end Performance Configuration (GHz)2.67
Low-end Performance Configuration Size Per DIMM (GB)16
Minimum Power Configuration Size Per DIMM (GB)16
Typical or Single Configuration Size Per DIMM (GB)64
Installed Num. DIMMs for Low-end Performance Configuration12
Installed Num. DIMMs for Minimum Power Configuration2
Installed Num. DIMMs for Typical or Single Configuration24
Installed Num. DIMMs for High-end Performance Configuration48
Installed Memory for Low-end Performance Configuration (GB)192
Installed Memory for Minimum Power Configuration (GB)31.7
Installed Memory for Typical or Single Configuration (GB)1536
Installed Memory for High-end Performance Configuration (GB)3000
I/O Device 1 Type Low-end Performance ConfigurationEthernet
I/O Device 1 Type Minimum Power ConfigurationEthernet
I/O Device 1 Type Typical or Single ConfigurationEthernet
I/O Device 1 Type High-end Performance ConfigurationEthernet
I/O Device 1 Link Speed Low-end Performance Configuration (Gbit)10
I/O Device 1 Link Speed Minimum Power Configuration (Gbit)10
I/O Device 1 Link Speed Typical or Single Configuration (Gbit)40
I/O Device 1 Link Speed High-end Performance Configuration (Gbit)10
I/O Device 1 Num. Active Ports Low-end Performance Configuration2
I/O Device 1 Num. Active Ports Minimum Power Configuration2
I/O Device 1 Num. Active Ports Typical or Single Configuration2
I/O Device 1 Num. Active Ports High-end Performance Configuration10
I/O Device 1 Attachment for Low-end Performance ConfigurationOnboard
I/O Device 1 Attachment for Minimum Power ConfigurationOnboard
I/O Device 1 Attachment for Typical or Single ConfigurationAdd-in
I/O Device 1 Attachment for High-end Performance ConfigurationAdd-in
I/O Device 2 Type Low-end Performance ConfigurationEthernet
I/O Device 2 Type Typical or Single ConfigurationEthernet
I/O Device 2 Type High-end Performance ConfigurationEthernet
I/O Device 2 Link Speed Low-end Performance Configuration (Gbit)40
I/O Device 2 Link Speed Typical or Single Configuration (Gbit)10
I/O Device 2 Ports Low-end Performance Configuration2
I/O Device 2 Ports Typical or Single Configuration2
I/O Device 2 Attachment for Low-end Performance ConfigurationOnboard
I/O Device 2 Attachment for Typical or Single ConfigurationAdd-in
I/O Device 3 Type Typical or Single ConfigurationEthernet
I/O Device 3 Type High-end Performance ConfigurationEthernet
I/O Device 3 Link Speed Typical or Single Configuration (Gbit)40.0
I/O Device 3 Ports Typical or Single Configuration2
I/O Device 3 Ports High-end Performance Configuration2
I/O Device 3 Attachment for Typical or Single ConfigurationAdd-in
I/O Device 3 Attachment for High-end Performance ConfigurationAdd-in
Low-end Performance Configuration Redundant Power SupplyYes
Minimum Power Configuration Redundant Power SupplyYes
Typical or Single Configuration Redundant Power SupplyYes
High-end Performance Configuration Redundant Power SupplyYes
Power Supply Type for Low-end Performance ConfigurationSingle-Output
Power Supply Type for Minimum Power ConfigurationSingle-Output
Power Supply Type for Typical or Single ConfigurationSingle-Output
Power Supply Type for High-end Performance ConfigurationSingle-Output
Power Supply Rated Output Low-end Performance Configuration (W)1600
Power Supply Rated Output Minimum Power Configuration (W)1600
Power Supply Rated Output Typical or Single Configuration (W)1600
Power Supply Rated Output High-end Performance Configuration (W)1600
Num. Power Supplies for Low-end Performance Configuration2
Num. Power Supplies for Minimum Power Configuration2
Num. Power Supplies for Typical or Single Configuration4
Num. Power Supplies for High-end Performance Configuration4
Number of PSU for Redundancy Low-end Performance Configuration2
Number of PSU for Redundancy Minimum Power Configuration2
Number of PSU for Redundancy Typical or Single Configuration4
Number of PSU for Redundancy High-end Performance Configuration4
PSU 80Plus Platinum Certified Low-end Performance ConfigurationYes
PSU 80Plus Silver Certified Minimum Power ConfigurationYes
PSU 80Plus Platinum Certified Typical or Single ConfigurationYes
PSU 80Plus Platinum Certified High-end Performance ConfigurationYes
Voltage for Idle Test Low-end Performance Configuration230 V
Voltage for Idle Test Minimum Power Configuration230 V
Voltage for Idle Test Typical or Single Configuration230 V
Voltage for Idle Test High-end Performance Configuration230 V
Idle Power Low-end Performance Configuration (W)215.02
Idle Power Minimum Power Configuration (W)185.96
Idle Power Typical or Single Configuration (W)465.98
Idle Power High-end Performance Configuration (W)533.74
Test Frequency for Idle Test Low-end Performance Configuration50
Test Frequency for Idle Test Minimum Power Configuration50
Test Frequency for Idle Test Typical or Single Configuration50
Test Frequency for Idle Test High-end Performance Configuration50
Air Temp. at Start of Test Low-end Performance Configuration (C)23
Air Temp. at Start of Test Minimum Power Configuration (C)23
Air Temp. at Start of Test Typical or Single Configuration (C)23
Air Temp. at Start of Test High-end Performance Configuration (C)23
Air Temp. End Idle Test Low-end Performance Configuration (C)23
Air Temp. End Idle Test Minimum Power Configuration (C)23
Air Temp. End Idle Test Typical or Single Configuration (C)23
Air Temp. End Idle Test High-end Performance Configuration (C)23
Air Temp. End Active Test Low-end Performance Configuration (C)23
Air Temp. End Active Test Minimum Power Configuration (C)23
Air Temp. End Active Test Typical or Single Configuration (C)23
Air Temp. End Active Test High-end Performance Configuration (C)23
Date Available On Market03/18/2018
Date Qualified10/19/2018
MarketsUnited States, Taiwan, Japan, Canada
ENERGY STAR Model IdentifierES 0021829 UCSC-C480-M5 10222018053031 70193986
EnergyStar Provided Specifications
Description Value
Type3 or 4 Socket Server (neither Blade nor Multi-node)
Form FactorRack-mount
Base Idle State Power Allowance Category for 1S and 2S ServersN/A
Single ServerNo
Resilient SystemNo
Managed ServerYes
Error Correcting CodeNo
Error Correcting Code Enabled in Hardware as ShippedNo
Available Expansion Slots2
Operating Systems SupportedWindows,Linux,Other
Operating System Used for TestingWindows
Power Saving Features AvailableVariable speed fan control based on power or thermal readings,Power capping,Low power memory states,Low power I/O states,Processor or core reduced power states,Dynamic voltage and frequency scaling of processor(s)
Power Saving Features EnabledVariable speed fan control based on power or thermal readings,Power capping,Low power memory states,Low power I/O states,Processor or core reduced power states,Dynamic voltage and frequency scaling of processor(s)
End User Required Power Saving FeaturesN/A
Storage Power Management Enabled in Hardware on ShipmentYes
Memory Power Management Enabled in Hardware on ShipmentYes
I/O Power Management Enabled in Hardware on ShipmentYes
Processor Dynamic Voltage Scaling Enabled on ShipmentYes
Processor Dynamic Frequency Scaling Enabled on ShipmentYes
Processor Dynamic Voltage Scaling End-User Enabling RequiredNo
Processor Dynamic Frequency Scaling End-User Enabling RequiredNo
Processor or Core Reduced Power States Enabled on ShipmentYes
Processor or Core Reduced Power States Enabling RequiredNo
Low Power Memory States Enabled on ShipmentYes
Low Power Memory States End-User Enabling RequiredNo
Low Power I/O States Enabled on ShipmentYes
Low Power I/O States End-User Enabling RequiredNo
Liquid Cooling Capability Enabled on ShipmentNo
Liquid Cooling Capability End-User Enabling RequiredNo
Available DIMM Slots48
Maximum Memory Capacity (GB)12000
Model Number or Config ID for Low-end Performance ConfigurationUCSC-C480-M5 (LE)
Model Number or Config ID for Minimum Power ConfigurationUCSC-C480-M5 (MP)
Model Number or Config ID for Typical or Single ConfigurationUCSC-C480-M5 (TC)
Model Number or Config ID for High-end Performance ConfigurationUCSC-C480-M5 (HE)
Installed Processors for Low-end Performance Configuration2
Installed Processors for Minimum Power Configuration2
Installed Processors for Typical or Single Configuration4
Installed Processors for High-end Performance Configuration4
Cores Per Processor Low-end Performance Configuration24
Cores Per Processor Minimum Power Configuration20
Cores Per Processor Typical or Single Configuration96
Cores Per Processor High-end Performance Configuration112
Number of Threads for Low-end Performance Configuration48
Number of Threads for Minimum Power Configuration40
Number of Threads for Typical or Single Configuration192
Number of Threads for High-end Performance Configuration224
Processor Brand Low-end Performance ConfigurationIntel
Processor Brand Minimum Power ConfigurationIntel
Processor Brand Typical or Single ConfigurationIntel
Processor Brand High-end Performance ConfigurationIntel
Processor Model Name Low-end Performance ConfigurationIntel(R) Xeon(R) Gold 5118 CPU @ 2.30GHz
Processor Model Name Minimum Power ConfigurationIntel(R) Xeon(R) Gold 5115 CPU @ 2.40GHz
Processor Model Name Typical or Single ConfigurationIntel(R) Xeon(R) Platinum 8160 CPU @ 2.10GHz
Processor Model Name High-end Performance ConfigurationIntel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz
Processor Speed for Low-end Performance Configuration (GHz)2.3
Processor Speed for Minimum Power Configuration (GHz)2.4
Processor Speed for Typical or Single Configuration (GHz)2.1
Processor Speed for High-end Performance Configuration (GHz)2.5
Num. of DDR Channels for Low-end Performance Configuration12
Num. of DDR Channels for Minimum Power Configuration2
Num. of DDR Channels for Typical or Single Configuration24
Num. of DDR Channels for High-end Performance Configuration48
Memory Speed Low-end Performance Configuration (GHz)2.67
Memory Speed Minimum Power Configuration (GHz)2.67
Memory Speed Typical or Single Configuration (GHz)2.67
Memory Speed High-end Performance Configuration (GHz)2.67
Low-end Performance Configuration Size Per DIMM (GB)16
Minimum Power Configuration Size Per DIMM (GB)16
Typical or Single Configuration Size Per DIMM (GB)64
Installed Num. DIMMs for Low-end Performance Configuration12
Installed Num. DIMMs for Minimum Power Configuration2
Installed Num. DIMMs for Typical or Single Configuration24
Installed Num. DIMMs for High-end Performance Configuration48
Installed Memory for Low-end Performance Configuration (GB)192
Installed Memory for Minimum Power Configuration (GB)31.7
Installed Memory for Typical or Single Configuration (GB)1536
Installed Memory for High-end Performance Configuration (GB)3000
I/O Device 1 Type Low-end Performance ConfigurationEthernet
I/O Device 1 Type Minimum Power ConfigurationEthernet
I/O Device 1 Type Typical or Single ConfigurationEthernet
I/O Device 1 Type High-end Performance ConfigurationEthernet
I/O Device 1 Link Speed Low-end Performance Configuration (Gbit)10
I/O Device 1 Link Speed Minimum Power Configuration (Gbit)10
I/O Device 1 Link Speed Typical or Single Configuration (Gbit)40
I/O Device 1 Link Speed High-end Performance Configuration (Gbit)10
I/O Device 1 Num. Active Ports Low-end Performance Configuration2
I/O Device 1 Num. Active Ports Minimum Power Configuration2
I/O Device 1 Num. Active Ports Typical or Single Configuration2
I/O Device 1 Num. Active Ports High-end Performance Configuration10
I/O Device 1 Attachment for Low-end Performance ConfigurationOnboard
I/O Device 1 Attachment for Minimum Power ConfigurationOnboard
I/O Device 1 Attachment for Typical or Single ConfigurationAdd-in
I/O Device 1 Attachment for High-end Performance ConfigurationAdd-in
I/O Device 2 Type Low-end Performance ConfigurationEthernet
I/O Device 2 Type Typical or Single ConfigurationEthernet
I/O Device 2 Type High-end Performance ConfigurationEthernet
I/O Device 2 Link Speed Low-end Performance Configuration (Gbit)40
I/O Device 2 Link Speed Typical or Single Configuration (Gbit)10
I/O Device 2 Ports Low-end Performance Configuration2
I/O Device 2 Ports Typical or Single Configuration2
I/O Device 2 Attachment for Low-end Performance ConfigurationOnboard
I/O Device 2 Attachment for Typical or Single ConfigurationAdd-in
I/O Device 3 Type Typical or Single ConfigurationEthernet
I/O Device 3 Type High-end Performance ConfigurationEthernet
I/O Device 3 Link Speed Typical or Single Configuration (Gbit)40.0
I/O Device 3 Ports Typical or Single Configuration2
I/O Device 3 Ports High-end Performance Configuration2
I/O Device 3 Attachment for Typical or Single ConfigurationAdd-in
I/O Device 3 Attachment for High-end Performance ConfigurationAdd-in
Low-end Performance Configuration Redundant Power SupplyYes
Minimum Power Configuration Redundant Power SupplyYes
Typical or Single Configuration Redundant Power SupplyYes
High-end Performance Configuration Redundant Power SupplyYes
Power Supply Type for Low-end Performance ConfigurationSingle-Output
Power Supply Type for Minimum Power ConfigurationSingle-Output
Power Supply Type for Typical or Single ConfigurationSingle-Output
Power Supply Type for High-end Performance ConfigurationSingle-Output
Power Supply Rated Output Low-end Performance Configuration (W)1600
Power Supply Rated Output Minimum Power Configuration (W)1600
Power Supply Rated Output Typical or Single Configuration (W)1600
Power Supply Rated Output High-end Performance Configuration (W)1600
Num. Power Supplies for Low-end Performance Configuration2
Num. Power Supplies for Minimum Power Configuration2
Num. Power Supplies for Typical or Single Configuration4
Num. Power Supplies for High-end Performance Configuration4
Number of PSU for Redundancy Low-end Performance Configuration2
Number of PSU for Redundancy Minimum Power Configuration2
Number of PSU for Redundancy Typical or Single Configuration4
Number of PSU for Redundancy High-end Performance Configuration4
PSU 80Plus Platinum Certified Low-end Performance ConfigurationYes
PSU 80Plus Silver Certified Minimum Power ConfigurationYes
PSU 80Plus Platinum Certified Typical or Single ConfigurationYes
PSU 80Plus Platinum Certified High-end Performance ConfigurationYes
Voltage for Idle Test Low-end Performance Configuration230 V
Voltage for Idle Test Minimum Power Configuration230 V
Voltage for Idle Test Typical or Single Configuration230 V
Voltage for Idle Test High-end Performance Configuration230 V
Idle Power Low-end Performance Configuration (W)215.02
Idle Power Minimum Power Configuration (W)185.96
Idle Power Typical or Single Configuration (W)465.98
Idle Power High-end Performance Configuration (W)533.74
Test Frequency for Idle Test Low-end Performance Configuration50
Test Frequency for Idle Test Minimum Power Configuration50
Test Frequency for Idle Test Typical or Single Configuration50
Test Frequency for Idle Test High-end Performance Configuration50
Air Temp. at Start of Test Low-end Performance Configuration (C)23
Air Temp. at Start of Test Minimum Power Configuration (C)23
Air Temp. at Start of Test Typical or Single Configuration (C)23
Air Temp. at Start of Test High-end Performance Configuration (C)23
Air Temp. End Idle Test Low-end Performance Configuration (C)23
Air Temp. End Idle Test Minimum Power Configuration (C)23
Air Temp. End Idle Test Typical or Single Configuration (C)23
Air Temp. End Idle Test High-end Performance Configuration (C)23
Air Temp. End Active Test Low-end Performance Configuration (C)23
Air Temp. End Active Test Minimum Power Configuration (C)23
Air Temp. End Active Test Typical or Single Configuration (C)23
Air Temp. End Active Test High-end Performance Configuration (C)23
Date Available On Market03/18/2018
Date Qualified10/19/2018
MarketsUnited States, Taiwan, Japan, Canada
ENERGY STAR Model IdentifierES 0021829 UCSC-C480-M5 10222018053031 70193986

Certifications & Resources

Device Name Model Certification Type Certification Date
UCSC-C480-M5 UCSC-C480-M5 Energy Star 2019-12-03
Energy Star Certification Details
Certification Description
 Certified models meet all ENERGY STAR requirements as listed in the Version 2.0 ENERGY STAR Program Requirements for Enterprise Servers that are effective as of December 16, 2013. A detailed listing of key efficiency criteria are available at http://www.energystar.gov/certified-products/detail/enterprise_servers
Descriptor Details
Partner NameCisco Systems
Model NameUCSC-C480-M5
Updated On2019-06-29
Last Update2022-04-25
Form FactorRack-mount
Product Processor Socket Count4
Single ServerNo
Resilient SystemNo
Error Correcting CodeYes
Error Correcting Code Enabled in Hardware as ShippedYes
Available Expansion Slots12
Operating Systems SupportedWindows,Linux,Other
Operating System Used for TestingWindows
Power Saving Features AvailableVariable speed fan control based on power or thermal readings,Processor or core reduced power states,Low power I/O states,Power capping,Low power memory states,Dynamic voltage and frequency scaling of processor(s)
Power Saving Features EnabledVariable speed fan control based on power or thermal readings,Processor or core reduced power states,Low power I/O states,Power capping,Low power memory states,Dynamic voltage and frequency scaling of processor(s)
End User Required Power Saving FeaturesN/A
Storage Power Management Enabled in Hardware on ShipmentYes
Memory Power Management Enabled in Hardware on ShipmentYes
I/O Power Management Enabled in Hardware on ShipmentYes
Processor Dynamic Voltage Scaling Enabled on ShipmentYes
Processor Dynamic Frequency Scaling Enabled on ShipmentNo
Processor Dynamic Voltage Scaling End-User Enabling RequiredNo
Processor Dynamic Frequency Scaling End-User Enabling RequiredNo
Processor or Core Reduced Power States Enabled on ShipmentNo
Processor or Core Reduced Power States Enabling RequiredNo
Power Capping Enabled on ShipmentNo
Power Capping End-User Enabling RequiredNo
Variable Speed Fan Control Enabled on ShipmentYes
Variable Speed Fan Control End-User Enabling RequiredNo
Low Power Memory States Enabled on ShipmentYes
Low Power Memory States End-User Enabling RequiredNo
Low Power I/O States Enabled on ShipmentYes
Liquid Cooling Capability Enabled on ShipmentNo
Liquid Cooling Capability End-User Enabling RequiredNo
Available DIMM Slots48
Maximum Memory Capacity (GB)6000
SERT Version Other
SERT Version Other  2.0.2
Model Number or Config ID for Low-end Performance ConfigurationUCSC-C480-M5 (LP)
Model Number or Config ID for Typical or Single ConfigurationUCSC-C480-M5 (TP)
Model Number or Config ID for High-end Performance ConfigurationUCSC-C480-M5 (HP)
Installed Processors for Low-end Performance Configuration2
Installed Processors for Typical or Single Configuration4
Installed Processors for High-end Performance Configuration4
Cores Per Processor Low-end Performance Configuration10
Cores Per Processor Typical or Single Configuration4
Cores Per Processor High-end Performance Configuration28
Number of Threads for Low-end Performance Configuration40
Number of Threads for Typical or Single Configuration80
Number of Threads for High-end Performance Configuration112
Processor Brand Low-end Performance ConfigurationIntel
Processor Brand Typical or Single ConfigurationIntel
Processor Brand High-end Performance ConfigurationIntel
Processor Model Name Low-end Performance ConfigurationIntel(R) Xeon(R) Gold 5115 CPU @ 2.40GH
Processor Model Name Typical or Single ConfigurationIntel(R) Xeon(R) Gold 6248 CPU @ 2.50GH
Processor Model Name High-end Performance ConfigurationIntel(R) Xeon(R) Platinum 8280 CPU
Processor Speed for Low-end Performance Configuration (GHz)2.4
Processor Speed for Typical or Single Configuration (GHz)2.5
Processor Speed for High-end Performance Configuration (GHz)2.7
Num. of DDR Channels for Low-end Performance Configuration24
Num. of DDR Channels for Typical or Single Configuration24
Num. of DDR Channels for High-end Performance Configuration48
Memory Manufacturer for Low-end Performance ConfigurationSamsung
Memory Manufacturer for Typical or Single ConfigurationSamsung
Memory Manufacturer for High-end Performance ConfigurationSamsung
Memory Model Number Low-end Performance Configuration16GB DDR4-2666-MHz RDIMM/2Rx4/1.2v;
Memory Model Number Typical or Single Configuration32GB DDR4-2933-MHz RDIMM/2Rx4/1.2v;
Memory Model Number High-end Performance Configuration64GB DDR4-2933-MHz RDIMM/2Rx4/1.2v
Memory Speed Low-end Performance Configuration (GHz)2.66
Memory Speed Typical or Single Configuration (GHz)2.93
Memory Speed High-end Performance Configuration (GHz)2.93
Low-end Performance Configuration Size Per DIMM (GB)16
Typical or Single Configuration Size Per DIMM (GB)32
High-end Performance Configuration Size Per DIMM (GB)64
Installed Num. DIMMs for Low-end Performance Configuration24
Installed Num. DIMMs for Typical or Single Configuration24
Installed Num. DIMMs for High-end Performance Configuration48
Installed Memory for Low-end Performance Configuration (GB)384
Installed Memory for Typical or Single Configuration (GB)768
Installed Memory for High-end Performance Configuration (GB)3072
Num. Solid State Drives (SSDs) Low-end Performance Configuration2
Num. Solid State Drives (SSDs) Typical or Single Configuration8
Num. Solid State Drives (SSDs) High-end Performance Configuration2
Number Rotational Drives Low-end Performance Configuration0
Number Rotational Drives Typical or Single Configuration0
Number Rotational Drives High-end Performance Configuration0
Low-end Performance Configuration Redundant Power SupplyYes
Typical or Single Configuration Redundant Power SupplyYes
High-end Performance Configuration Redundant Power SupplyYes
Power Supply Type for Low-end Performance ConfigurationSingle-Output
Power Supply Type for Typical or Single ConfigurationSingle-Output
Power Supply Type for High-end Performance ConfigurationSingle-Output
Power Supply Manufacturer Low-end Performance ConfigurationCisco Systems, Inc.
Power Supply Manufacturer Typical or Single ConfigurationCisco Systems Inc.
Power Supply Manufacturer High-end Performance ConfigurationCisco Systems Inc.
Power Supply Model Name Low-end Performance ConfigurationCIS-S-1600ADE00
Power Supply Model Name Typical or Single ConfigurationCIS-S-1600ADE00
Power Supply Model Name High-end Performance ConfigurationCIS-S-1600ADE00
Power Supply Model Number Low-end Performance ConfigurationCIS-S-1600ADE00
Power Supply Model Number Typical or Single ConfigurationCIS-S-1600ADE00
Power Supply Model Number High-end Performance ConfigurationCIS-S-1600ADE00
Power Supply Rated Output Low-end Performance Configuration (W)161
Power Supply Rated Output Typical or Single Configuration (W)806
Power Supply Rated Output High-end Performance Configuration (W)1614
Num. Power Supplies for Low-end Performance Configuration4
Num. Power Supplies for Typical or Single Configuration4
Num. Power Supplies for High-end Performance Configuration4
Number of PSU for Redundancy Low-end Performance Configuration4
Number of PSU for Redundancy Typical or Single Configuration4
Number of PSU for Redundancy High-end Performance Configuration4
64-bit Architecture64-bit supported
SERT Compress Eff. Score for Low-end Performance Configuration10.89
SERT Compress Eff. Score for Typical or Single Configuration15.27
SERT Compress Eff. Score for High-end Performance Configuration16.95
SERT CryptoAES Efficiency Score Low-end Performance Configuration16.74
SERT CryptoAES Efficiency Score Typical or Single Configuration23.02
SERT CryptoAES Efficiency Score High-end Performance Configuration20.42
SERT LU Efficiency Score Low-end Performance Configuration15.41
SERT LU Efficiency Score Typical or Single Configuration21.94
SERT LU Efficiency Score High-end Performance Configuration24.85
SERT SOR Efficiency Score Typical or Single Configuration12.56
SERT SOR Efficiency Score High-end Performance Configuration14.26
SERT SORT Efficiency Score Low-end Performance Configuration8.9
SERT SORT Efficiency Score Typical or Single Configuration13.76
SERT SORT Efficiency Score High-end Performance Configuration15.16
SERT SHA256 Efficiency Score Low-end Performance Configuration13.35
SERT SHA256 Efficiency Score Typical or Single Configuration20.34
SERT SHA256 Efficiency Score High-end Performance Configuration23.24
SERT Flood Efficiency Score Low-end Performance Configuration3.2
SERT Flood Efficiency Score Typical or Single Configuration2.25
SERT Flood Efficiency Score High-end Performance Configuration0.97
SERT Capacity Efficiency Score Low-end Performance Configuration23.58
SERT Capacity Efficiency Score Typical or Single Configuration32.3
SERT Capacity Efficiency Score High-end Performance Configuration32.65
SERT Sequential Efficiency Score Low-end Performance Configuration20.47
SERT Sequential Efficiency Score Typical or Single Configuration15.51
SERT Sequential Efficiency Score High-end Performance Configuration12.5
SERT Random Efficiency Score Low-end Performance Configuration194.5
SERT Random Efficiency Score Typical or Single Configuration157.22
SERT Random Efficiency Score High-end Performance Configuration124.22
SERT SSJ Efficiency Score Low-end Performance Configuration10.11
SERT SSJ Efficiency Score Typical or Single Configuration13.17
SERT SSJ Efficiency Score High-end Performance Configuration13.99
SERT Idle Measurement (Watts) Low-end Performance Configuration238.1
SERT Active State Efficiency Score Low-end Performance Configuration21
SERT Total Server Normalized Performance Score Low-end Performance Configuration18.15
SERT Total Server Power Score  (Watts) Low-end Performance Configuration564.90
SERT Idle Measurement (Watts) Typical or Single Configuration291.5
SERT Active State Efficiency Score Typical or Single Configuration29.1
SERT Total Server Normalized Performance Score Typical or Single Configuration33.58
SERT Total Server Power Score (Watts) Typical or Single Configuration817.67
SERT Idle Measurement (Watts) High-end Performance Configuration22.18
SERT Active State Efficiency Score High-end Performance Configuration186.19
SERT Total Server Normalized Performance Score High-end Performance Configuration20.47
SERT Total Server Power Score (Watts) High-end Performance Configuration194.5
Date Available On Market03/18/2018
Date Certified12/03/2019
MarketsUnited States, Taiwan, Japan, Canada
ENERGY STAR Model IdentifierES_0021829_UCSC-C480-M5_12062019025938_80025683
SERVER (ADPM) UCS C480 M5 Bureau of Indian Standards 2014-01-16 - 2024-01-15


Documents - cisco – ucs c480 m5,ucs-c480-m5,UCSC-C480-M5,UCS C480 M5,UCS C480 M5 ML,SERVER (ADPM),ucs_c480_m5
[pdf] Specifications
Cisco UCS C480 M5 High-Performance Rack Server Spec Sheet sandesk2 c480-m5-high-performance-specsheet cisco c dam en us products collateral servers-unified-computing ucs-c-series-rack-servers
Spec Sheet Cisco UCS C480 M5 High-Performance Rack-Mount Server CISCO SYSTEMS 170 WEST TASMAN DR. SAN JOSE, CA, 95134 WWW.CISCO.COM PUBLICATION HISTORY REV E.07 AUGUST 31, 2021 CONTENTS OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 DETAI...
lang:af score:107 filesize: 3.86 M page_count: 100 document date: 2021-09-01
[pdf] Guide
Cisco UCS C480 M5 メモリ ガイド memory guide exiqze107 c480 cisco c dam global ja jp products collateral servers unified computing ucs series rack |||
Cisco UCS C480 M5 CISCO SYSTEMS 170 WEST TASMAN DR SAN JOSE, CA, 95134 WWW.CISCO.COM/JP REV A.9 2021 7 13 CPU . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 DIMM PMem . . . . . ....
lang:it score:107 filesize: 2.23 M page_count: 38 document date: 2022-11-11
[pdf] Datasheet Guide
Cisco UCS C480 M5 Memory Guide sandesk2 C Series Rack Servers Data Sheets c480 memory guide cisco c dam en us products collateral servers unified computing ucs series rack |||
Guide Cisco UCS C480 M5 Memory Guide CISCO SYSTEMS 170 WEST TASMAN DR SAN JOSE, CA, 95134 WWW.CISCO.COM PUBLICATION HISTORY REV A.8 MAY 28, 2021 CONTENTS Server CPU Module Bay Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Memory Organization . . . . . . . . . . . . ....
lang:en score:106 filesize: 1.48 M page_count: 40 document date: 2021-05-28
[pdf] Specifications
Cisco UCS C480 M5 High Performance Rack Server Spec Sheet sandesk2 C Series Servers c480 m5 high performance specsheet cisco content dam en us products collateral servers unified computing ucs c series rack |||
Spec Sheet Cisco UCS C480 M5 High-Performance Rack-Mount Server CISCO SYSTEMS 170 WEST TASMAN DR. SAN JOSE, CA, 95134 WWW.CISCO.COM PUBLICATION HISTORY REV E.30 OCTOBER 30, 2023 CONTENTS OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 DET...
lang:af score:106 filesize: 5.71 M page_count: 100 document date: 2023-10-30
[pdf] User Manual Installation Guide Specifications Guide Warranty
Cisco UCS C480 M5 Server Installation and Service Guide Unknown Complete Book 13 67 MB Installing the C Series Rack Servers C480M5 cisco c en us td docs unified computing ucs hw install |||
Cisco UCS C480 M5 Server Installation and Service Guide First Published: 2017-10-12 Last Modified: 2021-01-19 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS 6387 Fax: 408 527-0883 THE SPECIFICATIONS ...
lang:en score:101 filesize: 13.67 M page_count: 192 document date: 2021-01-19
[pdf] Documentation
Руководство пользователя по установке сервера Cisco UCS C480 M5 Administrator C480M5 EAC cisco c dam global ru documentation 2018 |||
Cisco UCS C480 M5 Cisco UCS C480 M5 Cisco UCS C480 M5 , , . , . 4RU Intel Xeon 48 DIMM 12 DIMM PCIe 2,5- 6,35 , ; 24 2,5- 6,35 4 . , . 2 , . 4. ...
lang:de score:100 filesize: 1.79 M page_count: 16 document date: 2018-10-09
[pdf]
Cisco UCS C480 M5 Rack Server Disk I O Characterization White Paper Sherry Jennings whitepaper c11 741970 cisco c dam en us products collateral servers unified computing ucs series rack |||
White Paper Cisco UCS C480 M5 Rack Server Disk I/O Characterization February 2019 2019 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 1 of 44 White Paper Contents Executive summary ..................................................................
lang:en score:97 filesize: 3.78 M page_count: 44 document date: 2021-02-01
[pdf] Specifications
Cisco UCS C480 M5 高性能ラックマウント サーバ 製品仕様・構成ガイド 更新日 2019 4 2 exiqze109 c480 m5 high performance specsheet cisco c dam global ja jp products collateral servers unified computing ucs series rack |||
Cisco UCS C480 M5 CISCO SYSTEMS 170 WEST TASMAN DR. SAN JOSE, CA, 95134 WWW.CISCO.COM/JP REV D.28 2021 5 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
lang:i-klingon score:96 filesize: 5.61 M page_count: 100 document date: 2021-08-12
[pdf] Datasheet
Cisco UCS C480 M5 ラック サーバ データ シート RR Donnelley datasheet c78 739291 cisco c ja jp products collateral servers unified computing ucs series rack |||
Cisco UCS C480 M5 2018 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. 1/7 Cisco UCS C480 M5 4 4 RU Cisco UCS C480 M5 I/O VDI C480 M5 4 RU Cisco Unified Computing SystemTMCisco UCS 4 2 Intel Xeon CPU 28 4 Intel Xeon CPU 28 ...
lang:en score:95 filesize: 650.55 K page_count: 7 document date: 2020-11-12
[pdf] Datasheet
Cisco UCS C480 M5 Rack Server Data Sheet Administrator datasheet c78 739291 cisco c en us products collateral servers unified computing ucs series rack |||
Cisco UCS C480 M5 Rack Server Data Sheet The Cisco UCS C480 M5 Rack Server delivers a no-compromise balance of performance, expansion capabilities, and flexibility to scale in a 4-Rack-Unit 4RU form-factor. Product overview The Cisco UCS C480 M5 Rack Server is a storage- and I/O-optimized enterp...
lang:en score:94 filesize: 398.19 K page_count: 5 document date: 2018-03-20
[pdf] Specifications Datasheet Warranty
Cisco UCS C480 M5 Rack Server Data Sheet RR Donnelley datasheet c78 739291 cisco content en us products collateral servers unified computing ucs c series rack |||
Data sheet Cisco public D Cisco UCS C480 M5 Rack Server 2022 Cisco and/or its affiliates. All rights reserved. Page 1 of 8 Contents Product overview 3 Features and benefits 4 Storage and I/O optimized for industry-leading performance 5 Product specifications 6 System requirements 7 O...
lang:en score:92 filesize: 429.44 K page_count: 8 document date: 2022-03-25
[pdf] Specifications Datasheet Warranty
Cisco UCS C480 M5 Rack Server Data Sheet RR Donnelley © 2020 and or its affiliates All rights reserved This document is Public Information Page 1 of 8 vtc telepresence |||
Data Sheet Cisco UCS C480 M5 Rack Server 2020 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 1 of 8 Contents Product Overview 3 Features and Benefits 4 Storage and I/O Optimized for Industry-Leading Performance 5 Product Specifications ...
lang:en score:92 filesize: 420.83 K page_count: 8 document date: 2020-05-18
[pdf] Datasheet
思科 UCS C480 M5 機架式伺服器 RR Donnelley datasheet c78 739291 cisco c zh tw products collateral servers unified computing ucs series rack |||
UCS C480 M5 4 4RU UCS C480 M5 UCS C480 M5 I/O VDI 4RU C480 M5 UCS Intel Xeon 28 2 4 2666 MHz DDR4 48 DIMM 6 TeraBytes TB 12 PCI Express PCIe 3.0 6 x8 6 x16 32 SFF 2.5 SASSATA PCIe NVMe 12 Gbps SAS RAID SD M.2 10 Gigabit LAN LOM ...
lang:en score:91 filesize: 861.85 K page_count: 5 document date: 2017-09-19
[pdf] Datasheet
Cisco UCS C480 M5 Rack Server Data Sheet RR Donnelley sheet public © 2017 and or its affiliates All rights reserved This document is Public Information Page 1 of 5 79BFCAC8 8B9F 41BC AD75 4F58CF19DD8E media howard CNET Product |||
Data sheet Cisco public Cisco UCS C480 M5 Rack Server The Cisco UCS C480 M5 Rack Server delivers a no-compromise balance of performance, expansion capabilities, and flexibility to scale in a 4-Rack-Unit 4RU form-factor. Product overview The Cisco UCS C480 M5 Rack Server is a storage- and I/O-opti...
lang:en score:88 filesize: 478.12 K page_count: 5 document date: 2017-10-10
[pdf] Guide
新機能および変更された機能に関する情報 Unknown b Cisco UCS Manager Server Mgmt CLI Guide 4 0 chapter 01 cisco c ja jp td docs unified computing ucs manager User Guides |||
1 Cisco UCS Manager4.0 2a Cisco UCS C480 M5 ML Server Cisco UCS ManagerCisco UCS C480 M5 ML Server Cisco UCS VIC 1495 Cisco UCS ManagerCisco UCS VIC 1495 Cisco UCS VIC 1497 Cisco UCS ManagerCisco UCS VIC 1497 Cisco UCS Manager4.0 1a 1 1 : Cisco UCS Manager...
lang:tl score:85 filesize: 1.04 M page_count: 2 document date: 2019-04-24
[pdf] Guide
Cisco UCS C Series Integration with Manager Unknown b UCSM4 0 chapter 01 cisco c en us td docs unified computing ucs series integration ucsm4 |||
Cisco UCS C-Series Integration with Cisco UCS Manager This chapter includes the following sections: ... UCS VIC 1497 supported only in C220 M5 and C240 M5 servers Note Cisco UCS C125 M5 Servers, Cisco UCS C480 M5 Servers, and Cisco UCS C480 M5 ML Servers do not support MLOM adapters. Note The Cisco ...
lang:en score:84 filesize: 1.33 M page_count: 18 document date: 2021-02-02
[pdf]
思科 UCS C480 M5 机架式服务器 C 系列机架式服务器 概述 Cisco at a glance c45 739274 cisco c dam global zh cn products collateral servers unified computing ucs series rack |||
UCS C480 M5 UCS C480 M5 4 UCS C TM UCS TCO UCS C480 M5 UCS Intel Xeon 14 266 NVMe SSD 10 PCIe 20 GPU 3 C480 M5 CPU Intel Xeon 6 TB SAP SAP HANASQLOracle GPU VDI TM UCS UCS M5 2017 / UCS C480 M5 UCS www.cisco.com/go/ucs UCS C480 M...
lang:nl score:81 filesize: 145.92 K page_count: 2 document date: 2017-12-08
[pdf] Guide
Cisco UCS C Series Integration with Manager Unknown 16 août 2023 — This guide contains information and procedures for installing Rack Mount Servers integration m lbmr1 c integ overview 4 3 cisco en us td docs unified computing ucs series ucsm4 b |||
Cisco UCS C-Series Integration with Cisco UCS Manager This chapter includes the following sections: ... 0 M5 UCSC-C220-M5L Cisco UCS C220 M5 UCSC-C220-M5SX Cisco UCS C220 M5 UCSC-C220-M5SN Cisco UCS C480 M5 UCSC-C480-M5 Cisco UCS C480 M5 ML Server USC-C480-M5ML Note Cisco UCS C125 M5 Serve...
lang:en score:80 filesize: 1.47 M page_count: 24 document date: 2023-08-16
[pdf] Release Notes Catalog
Release Notes for Cisco UCS C Series Product ID Catalog 4 0 Unknown b RN cisco c en us td docs unified computing ucs release PID |||
Release Notes for Cisco UCS C-Series Product ID Catalog, Release 4.0 First Published: 2018-09-07 La ... G1RW Supported Platforms Minimum Software Version C220 M5, C240 M5, C240 SD M5, 4.0 4n C480 M5, UCS C480 M5 ML, and S3260 M5 servers C220 M5, C240 M5, C240 SD M5, 4.0 4n C480 M5, UCS C480 M5 ML,...
lang:en score:76 filesize: 182.44 K page_count: 10 document date: 2022-10-03
[pdf] Release Notes
for Cisco UCS Server Configuration Utility リリースノート exiqze228 Release Notes C Series 5 1 cisco c dam global ja jp td docs unified computing ucs release notes
Cisco UCS Server Configuration Utility 2017 10 20 : 2019 9 9 UCS SCU 17 Cisco.com C 1 C 1 H0 G0 F0 E0 D0 C0 B0 A0 2019 9 9 6.0 4c 2019 9 4 6.0 2b 2019 6 11 6.0 4 2019 2 25 6.0 2 2018 10 26 6.0 1 2018 4 27 5.1 3 2017 11 2...
lang:en score:73 filesize: 474.16 K page_count: 18 document date: 2019-10-31
[pdf] Release Notes
Cisco UCS C シリーズ ソフトウェア リリース 4 0 2 ノート Unknown b Series RN cisco c ja jp td docs unified computing ucs release notes |||
Cisco UCS C 4.0 2 2019 1 2 2020 5 5 Cisco UCS C Cisco UCS C I/O Cisco Integra ... 460 M4 UCS S3260 M4 UCS S3260 M5 4.0 2d UCS S3260 M4 UCS C125 M5 UCS C220 M5 UCS C240 M5 UCS C480 M5 UCS S3260 M5 4.0 2c UCS C480 M5 ML UCS C125 M5 UCS C220 M5 UCS C240 M5 UCS C480...
lang:it score:72 filesize: 659.76 K page_count: 46 document date: 2020-07-28
[pdf] Configuration Guide
Cisco UCS C シリーズと Manager との統合 Unknown This Chapter 1 5 MB シリーズ サーバと 4 0 の統合ガイド Series Rack Mount Managed Server Software b Integration UCSM4 chapter 01 cisco c ja jp td docs unified computing ucs series integration ucsm4 |||
Cisco UCS C Cisco UCS Manager 1 C Cisco UCS Manager 2 FEX 5 FEX vNIC/vHBA 6 7 ... UCS VIC 1495Cisco UCS C125 M5 M5 Cisco UCS VIC 1497 C220 M5 C240 M5 Cisco UCS C125 M5 Cisco UCS C480 M5 Cisco UCS C480 M5 ML MLOM Cisco UCS VIC 1225T 1227T Cisco Nexus 2232TM-E 10GE R...
lang:en score:71 filesize: 1.5 M page_count: 20 document date: 2020-12-15
[pdf] Documentation Release Notes
Release Notes for Cisco UCS Rack Server Software 4 2 Unknown b release notes cisco ucs rack server software c en us td docs unified computing |||
Release Notes for Cisco UCS Rack Server Software, Release 4.2 2 First Published: 2022-07-08 Last Mo ... o UCS C245 M6 Cisco UCS C225 M6 Cisco UCS C220 M5 Cisco UCS C240 M5 Cisco UCS C240 SD M5 Cisco UCS C480 M5 Cisco UCS S3260 M5 Cisco UCS C480 M5 Cisco UCS C480 M5 ML Cisco UCS C125 M5 Cisco U...
lang:en score:71 filesize: 365.28 K page_count: 37 document date: 2023-04-20
[pdf]
Cisco UCS C シリーズ サーバと Manager 4 0 の統合ガイド Unknown Complete Book 38 MB シリーズと との統合 Series Rack Mount Managed Server Software b Integration UCSM4 cisco c ja jp td docs unified computing ucs series integration ucsm4 |||
Cisco UCS C Cisco UCS Manager 4.0 2018 8 14 2020 7 7 107-6227 9-7-1 http://www.cisco.com ... UCS VIC 1495Cisco UCS C125 M5 M5 Cisco UCS VIC 1497 C220 M5 C240 M5 Cisco UCS C125 M5 Cisco UCS C480 M5 Cisco UCS C480 M5 ML MLOM Cisco UCS VIC 1225T 1227T Cisco Nexus 2232TM-E 10GE R...
lang:en score:70 filesize: 4.38 M page_count: 96 document date: 2020-12-15
[pdf] Guide
Cisco UCS C Series Integration with Manager Unknown b UCSM3 2 chapter 01 cisco c en us td docs unified computing ucs series integration ucsm3 |||
Cisco UCS C-Series Integration with Cisco UCS Manager This chapter includes the following sections: ... ese drives are managed by the SAS controller placed in the dedicated MRAID PCIe slot. UCS C480 M5--UCS C480 M5 servers support up to three front NVMe drive cages, each supporting up to eight NVMe dri...
lang:en score:70 filesize: 1.36 M page_count: 18 document date: 2019-05-07
[pdf] Documentation Release Notes
Release Notes for Cisco UCS Rack Server Software 4 0 2 Unknown b C Series RN cisco c en us td docs unified computing ucs release notes |||
Release Notes for Cisco UCS Rack Server Software, Release 4.0 2 First Published: 2019-01-02 Last Mo ... ty Matrix Supported Platforms in this Release The following servers are supported in this release: UCS C480 M5 ML UCS C125 M5 UCS C220 M5 UCS C240 M5 UCS C480 M5 UCS S3260 M5 UCS S3260 M4 UCS ...
lang:en score:69 filesize: 452.45 K page_count: 46 document date: 2021-06-27
[pdf] Documentation
Cisco UCS C Series Server Integration with Manager 4 0 Unknown b UCSM4 cisco c en us td docs unified computing ucs series integration ucsm4 |||
Cisco UCS C-Series Server Integration with Cisco UCS Manager 4.0 First Published: 2018-08-14 Last Mo ... UCS VIC 1497 supported only in C220 M5 and C240 M5 servers Note Cisco UCS C125 M5 Servers, Cisco UCS C480 M5 Servers, and Cisco UCS C480 M5 ML Servers do not support MLOM adapters. Note The Cisco ...
lang:en score:69 filesize: 4.2 M page_count: 86 document date: 2021-02-02
[pdf] Configuration Guide
Cisco UCS C シリーズと Manager との統合 Unknown This Chapter 1 51 MB シリーズ サーバと 4 の統合ガイド Series Rack Mount Managed Server Software b Integration UCSM4 chapter 01 cisco c ja jp td docs unified computing ucs series integration ucsm4 |||
Cisco UCS C Cisco UCS Manager 1 C Cisco UCS Manager 2 FEX 5 FEX vNIC/vHBA 6 7 ... UCS VIC 1495Cisco UCS C125 M5 M5 Cisco UCS VIC 1497 C220 M5 C240 M5 Cisco UCS C125 M5 Cisco UCS C480 M5 Cisco UCS C480 M5 ML MLOM Cisco UCS VIC 1225T 1227T Cisco Nexus 2232TM-E 10GE R...
lang:en score:68 filesize: 1.51 M page_count: 22 document date: 2020-12-09
[pdf]
HPE ProLiant AMD Servers Gain 7 World Performance Records for Decision Support Database The DL325 Gen10 delivered the first and 1 one processor 1P 4 node result on VMmark 3 benchmark results indicate that platform is a front runner virtualization DL345 Plus DL385 v2 EPYC 3rd generation processors TPC H @3000GB @10000GB Cisco UCS C480 M5 C240 a50003877enw hpe socialmedia@hpe Brief New Workloads PD fe5e0932bbdbee188a67 ade54de1bba9a4fe61c120942a09245b ssl cf1 rackcdn utm content 237139110 medium social source twitter hss channel tw 3223639363 |||
Performance brief Check if the document is available in the language of your choice. HPE PROLIANT AM ... lt for TPC-H 10000GB scale factor Best 2P performance 2P DL385 Gen10 Plus v2 beats the 4P Cisco UCS C480 M5 Server 14 more performance than 4P Cisco and 16.42 less cost than previous best, the ...
lang:en score:68 filesize: 210.94 K page_count: 2 document date: 2022-03-31
[pdf] User Manual Specifications Warranty
Cisco UCS C シリーズ サーバと Manager 4 1 の統合ガイド Unknown Complete Book 41 MB シリーズと との統合 Series Rack Mount Managed Server Software b Integration UCSM4 cisco c ja jp td docs unified computing ucs series integration ucsm4 |||
Cisco UCS C Cisco UCS Manager 4.1 2020 2 20 2020 7 30 107-6227 9-7-1 http://www.cisco.co ... UCS VIC 1495Cisco UCS C125 M5 M5 Cisco UCS VIC 1497 C220 M5 C240 M5 Cisco UCS C125 M5 Cisco UCS C480 M5 Cisco UCS C480 M5 ML MLOM Cisco UCS VIC 1225T 1227T Cisco Nexus 2232TM-E 10GE R...
lang:en score:67 filesize: 4.41 M page_count: 102 document date: 2020-12-09
[pdf] Release Notes
Release Notes for Cisco UCS Server Diagnostic Utilities Unknown Diagnostics Utility b release notes cisco ucs server diagnostics utility c en us td docs unified computing |||
Release Notes for Cisco UCS Server Diagnostic Utilities First Published: 2017-04-27 Last Modified: 2022-12-22 Cisco UCS Server Diagnostics Utilities Cisco provides the following diagnostics utilities for Cisco UCS C-Series Servers: 1. Cisco UCS Server Diagnostics Utility --The Cisco UCS Server Diagn...
lang:en score:66 filesize: 223.66 K page_count: 8 document date: 2022-12-08
[pdf] User Manual Specifications Warranty
Cisco UCS C Series Server Integration with Manager 4 2 Unknown Complete Book 35 MB b UCSM4 cisco content en us td docs unified computing ucs c series integration ucsm4 |||
Cisco UCS C-Series Server Integration with Cisco UCS Manager 4.2 First Published: 2021-06-24 Last Mo ... UCS 6200 Series Fabric Interconnects. Cisco UCS C460 M4 Servers, Cisco UCS C125 M5 Servers, Cisco UCS C480 M5 Servers, and Cisco UCS C480 M5 ML Servers, Cisco UCS C225 M6 and C245 M6 Servers do not ...
lang:en score:66 filesize: 4.36 M page_count: 94 document date: 2023-04-11
[pdf] Guide
Storage Inventory Unknown Once you have set up VMD can customize LED blinking patterns on PCIe NVMe drives Information customization be found in the User Guides included m gui storage inventory cisco c en us td docs unified computing ucs manager GUI Mgmt 4 3 b ucsm management guide |||
Storage Inventory Local Disk Locator LED Status, on page 1 Toggling the Local Disk Locator LED On ... ese drives are managed by the SAS controller placed in the dedicated MRAID PCIe slot. UCS C480 M5--UCS C480 M5 servers support up to three front NVMe drive cages, each supporting up to eight NVMe dri...
lang:en score:63 filesize: 1.11 M page_count: 18 document date: 2023-08-16
[pdf] Decleration of Conformity
18799431 cisco web dofc |||
Enterprise Server Product Environmental Information Declaration Form per COMMISSION REGULATION EU ... X X HDDs 5 25 g 25 g Instructions on the disassembly operations clause 3.3 b Please use UCS C480 M5 Server Installation and Service Guide for detail. Instruction on the secure data deletio...
lang:en score:63 filesize: 203.64 K page_count: 4 document date: 0000-00-00
[pdf]
SingleConnect の設定 Unknown This Chapter 1 92 MB Cisco UCS C シリーズ サーバと Manager 4 の統合ガイド Series Rack Mount Managed Server Software b Integration UCSM4 chapter 010 cisco c ja jp td docs unified computing ucs series integration ucsm4 |||
SingleConnect SingleConnect 1 SingleConnect 2 2 GUI 3 CLI 3 SingleConnect Cisco UCS ... i.0 3.2 1d 3.1.1d 3.1.1i.0 Cisco UCS C240 M5 3.1.1d 3.1.1h.0 3.2 1d 3.1.1d 3.1.1h.0 Cisco UCS C480 M5 3.1 2b 3.1.2a.0 3.2 2b 3.1 2b 3.1.2a.0 Cisco UCS C125 M5 4.0 1a 4.0 1a 4.0 1...
lang:fr score:63 filesize: 1.93 M page_count: 22 document date: 2020-12-09
[pdf] Guide
Hardware Monitoring Unknown This Chapter 1 26 MB Cisco UCS Manager System Guide Release 4 2 b UCSM GUI chapter 01100 cisco c en us td docs unified computing ucs manager User Guides |||
Hardware Monitoring Monitoring a Fabric Interconnect, on page 1 Monitoring a Blade Server, on pag ... ck server Cisco UCS C460 M4 rack server Cisco UCS C220 M5 Server Cisco UCS C240 M5 Server Cisco UCS C480 M5 Server Cisco UCS C220 M6 Server Cisco UCS C240 M6 Server Cisco UCS C225 M6 Server Ci...
lang:en score:62 filesize: 1.27 M page_count: 32 document date: 2023-06-05
[pdf] Guide
New and Changed Information Unknown This Chapter 0 96 MB Cisco UCS Manager Server Management Using the CLI Release 3 2 b Mgmt Guide chapter 010000 cisco c en us td docs unified computing ucs manager User Guides |||
New and Changed Information New and Changed Information, on page 1 New and Changed Information N ... co UCS Cisco UCS Manager support for Rack Server Power Management C480 M5 Server and Cisco UCS the UCS C480 M5 rack-mount B480 M5 Server. server and B480 M5 blade server. New and Changed Informati...
lang:en score:62 filesize: 984.88 K page_count: 2 document date: 2019-06-11
[pdf]
Annonce d arrêt de commercialisation et fin vie Cisco Unified Computing System C Series Rack Severs C220 M4 C240 and C460 RR Donnelley eos eol notice c51 741235 fr cisco c en us products collateral servers unified computing ucs series rack |||
Avis de produit en fin de vie Cisco public Annonce d arrt de commercialisation et de fin de vie de C ... hassis w/o UCSC-C480-M5= CPU/DIMM/HDD UCS C240 M5 8 SFF 2 rear drives w/o CPU, mem, HD, PCIe, PS UCS C480 M5 Std base chassis w/o CPU, mem, HDD, PCIe, PSU DISTI: UCS C480 M5 std base chassis w/HS U...
lang:fr score:61 filesize: 508.01 K page_count: 12 document date: 2019-08-25
[pdf] Guide
vi vdga guide vmware resources compatibility
Virtual Dedicated Graphics Acceleration vDGA Guide Virtual Dedicated Graphics Acceleration vDGA ... raphics Acceleration vDGA Guide Server Partner Cisco Cisco Cisco Cisco Cisco Server Model Cisco UCS C480 M5 Cisco UCS C480 M5 Cisco UCS C480 M5 Cisco UCS C480 M5 Cisco UCS C480 M5 GPU Partner NVI...
lang:en score:61 filesize: 74.09 K page_count: 46 document date: 2021-08-27
[pdf] Label
Accelerate AI Data Pipeline with FlashStack cisco c dam en us training events Strata Conference
ACCELERATE AI DATA PIPELINE With FlashStack by Cisco and Pure Storage 1 TM COMPLEXITIES OF AI IN ... /2019 CONFIDENTIAL DOCUMENT, DO NOT SHARE OR DISTRIBUTE. TM ANNOUNCING FLASHSTACK FOR AI Cisco UCS C480 M5 ML: Next-Gen AI Server Purpose-built rack-scale solution for Deep Learning Eight NVID...
lang:en score:61 filesize: 1.05 M page_count: 12 document date: 2019-10-08
[pdf] Documentation Guide
Cisco UCS Server Diagnostics Utility User Guide Unknown b 50 cisco c en us td docs unified computing ucs sw ucsscu scu diag user guide Last Modified 2021 03 09 quick tests such as processor memory disk cache |||
Cisco UCS Server Diagnostics Utility User Guide First Published: 2017-01-23 Last Modified: 2021-03-09 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS 6387 Fax: 408 527-0883 20172020 Cisco Systems, In...
lang:en score:61 filesize: 2.11 M page_count: 32 document date: 2021-03-09
[pdf]
ConnectX® 5 EN Card 25 and 100 Gb s Ethernet Adapter PCIe adapter for Cisco UCS C Series pb connectx en card cisco 7b Jan 2020 c dam us products collateral servers unified computing ucs series rack |||
ADAPTER CARD PRODUCT BRIEF ConnectX-5 EN Card 25 and 100 Gb/s Ethernet Adapter Card Intelligent RDM ... SFP28, PCIe3.0 x16, tall bracket Cisco UCS C220 M5 Rack Server Cisco UCS C240 M5 Rack Server Cisco UCS C480 M5 Rack Server ConnectX-5 Ex EN network interface card, 100GbE dual-port QSFP28, PCIe4.0 x...
lang:en score:61 filesize: 424.17 K page_count: 4 document date: 2020-01-14
[pdf]
Cisco UCS C240 M5 Rack Server Delivers Unsurpassed Price per Performance on the TPC H Benchmark continues to demonstrate industry leadership with first world record result at 10 TB Linux Systems le 67201 pb tpch 1806713 cisco c dam en us solutions collateral data center microsoft sql server ucs |||
Solution Brief Cisco Public Cisco UCS C480 M5 Rack Server Delivers Unsurpassed Price-perPerformance on the TPC-H Benchmark An industry first World-record TPC-H 4-socket result at 10 TB1 World-record Microsoft SQL Server 2017 4-socket result1 First world-record TPC-H 4-socket result at 10 TB on L...
lang:en score:60 filesize: 304.29 K page_count: 3 document date: 2019-04-29
[pdf] Guide
Cisco UCS Manager リリース 4 0 ストレージ管理ガイド Unknown b UCSM GUI Storage Management Guide cisco c ja jp td docs unified computing ucs manager User Guides Mgmt |||
Cisco UCS Manager 4.0 2018 8 14 2019 8 26 107-6227 9-7-1 http://www.cisco.com/jp 0120-09 ... 2xx PCIe SATA 6Gb/s Cisco M.2 UCS-M2-HWRAID Cisco UCS C220 M5 Cisco UCS C240 M5 Cisco UCS C480 M5 Cisco UCS B200 M5 Cisco UCS B480 M5 2 Cisco M. 2 RAID 240GB M.2 6G SATA SSD 96...
lang:de score:59 filesize: 4.8 M page_count: 232 document date: 2019-12-05
[pdf] User Manual Specifications Warranty
Cisco UCS C Series Server Integration with Manager 3 2 Unknown b UCSM3 cisco c en us td docs unified computing ucs series integration ucsm3 |||
Cisco UCS C-Series Server Integration with Cisco UCS Manager 3.2 First Published: 2017-08-18 Last Mo ... ese drives are managed by the SAS controller placed in the dedicated MRAID PCIe slot. UCS C480 M5--UCS C480 M5 servers support up to three front NVMe drive cages, each supporting up to eight NVMe dri...
lang:en score:58 filesize: 3.09 M page_count: 74 document date: 2019-05-07
[pdf] User Manual Guide
Power Management in Cisco UCS Unknown b UCSM GUI Infrastructure Guide chapter 0111 cisco c en us td docs unified computing ucs manager User Guides Mgmt 4 2 |||
Power Management in Cisco UCS Power Capping in Cisco UCS, on page 2 Power Policy Configuration, on ... 0 M4 Server Cisco UCS C220 M5 Server Cisco UCS C240 M5 Server Cisco UCS C240 SD M5 Server Cisco UCS C480 M5 Server Cisco UCS C480 M5 ML Server Cisco UCS C220 M6 Server Cisco UCS C240 M6 Server ...
lang:en score:58 filesize: 1.23 M page_count: 28 document date: 2022-09-21
[pdf] Guide
ガイドラインと前提条件 Unknown This Chapter 1 67 MB Cisco UCS Manager ファームウェア リリース 4 0 管理ガイド b UCSM GUI Firmware Management Guide chapter 010 cisco c ja jp td docs unified computing ucs manager User Guides Mgmt |||
1 Cisco UCS Central 15 16 17 31 Cisco UCS Cisco UCS ... o UCS C220 M4 Cisco UCS C220 M5 Cisco UCS B200 M4 Cisco UCS B200 M5 Cisco UCS B480 M5 Cisco UCS C480 M5 Cisco Intel NVMe Cisco UCS B200 M5 Cisco UCS B480 M5 1 : NVMe NVMe...
lang:nl score:58 filesize: 1.68 M page_count: 34 document date: 2019-09-20
[pdf] Documentation Guide Configuration Guide
概要 Unknown This Chapter 1 32 MB Cisco UCS C シリーズ Integrated Management Controller リリース 4 GUI コンフィギュレーション ガイド b series Configuration Guide 41 chapter 01 cisco c ja jp td docs unified computing ucs sw gui config guide |||
Cisco UCS C 1 2 Cisco Integrated Management Controller 2 Cisco IMC 4 Cisco UCS C Cisco UCS C Cisco UCS C240 SD M5 Cisco UCS C125 Cisco UCS C220 M5 Cisco UCS C240 M5 Cisco UCS C480 M5 Cisco UCS C220 M4 Cisco UCS C240 M4 Cisco UCS C460 M4 Cisco UCS C ...
lang:it score:58 filesize: 1.32 M page_count: 12 document date: 2020-10-01
[pdf]
Configuring Direct Connect Unknown b C Series Integration UCSM4 0 chapter 011 cisco c en us td docs unified computing ucs series integration ucsm4 |||
Configuring Direct Connect This chapter includes the following sections: Direct Connect Mode, on pa ... nnect Mode Integration with Cisco UCS Manager Server CIMC Cisco UCS C240 M5 3.1.1d Server Cisco UCS C480 M5 3.1 2b Server Cisco UCS C125 M5 4.0 1a Server Cisco UCS C480 M5 4.0 2a ML Server B...
lang:en score:58 filesize: 1.85 M page_count: 16 document date: 2021-02-02
[pdf] User Manual Specifications Guide Warranty
FlexPod Datacenter for SAP Solution using FibreChannel SAN with Cisco UCS Manager 4 0 and NetApp ONTAP 9 7 Design Guide Lisa DeRuyter lideruyt jeffnich@cisco flexpod sap ucsm40 fcsan design cisco c en us td docs unified computing ucs CVDs |||
FlexPod Datacenter for SAP Solution using FibreChannel SAN with Cisco UCS Manager 4.0 and NetApp ONT ... Figure 9. Cisco UCS VIC 1440 Figure 10. Cisco VIC UCS 1480 Table 1. Supported Servers Cisco UCS C480 M5 Rack Server The Cisco UCS C480 M5 Rack Server Figure 11 can be deployed as a standalon...
lang:en score:58 filesize: 2.33 M page_count: 62 document date: 2021-09-21

Search Any Device: