Duct S (HSP) Max Heat - Samsung
Specifications & Energy Star Certification #2411667
EnergyStar Certifications
ENERGY STAR Certified Central Air Conditioners and Air-Source Heat Pumps
Device Name | Model Number | Company | Certification Date |
---|---|---|---|
HP - Mini or Multi Split | 2023-03-10 |
Descriptor | Details |
---|---|
Partner Name | Samsung Electronics Co., Ltd. |
Updated On | 2024-03-28 |
Last Update | 2024-03-29 |
Manufacturer Type | System Manufacturer |
Series Name | Duct S (HSP) Max Heat |
Outdoor Unit Brand Name | Samsung |
Outdoor Unit Model Number | AC030BXSCCH |
Indoor Unit Brand Name | SAMSUNG |
Indoor Unit Model Number | AC030BNHDCH |
Cold Climate | Yes |
Meets Peak Cooling Requirements | Yes |
SEER2 (Btu/Wh) | 18.7 |
EER2 (Btu/Wh) | 12 |
HSPF2 (Btu/Wh) | 8.6 |
Cooling Capacity (Btu/h) | 30000 |
Heating Capacity at 47°F (Btu/h) | 32000 |
Heating Capacity at 17°F (Btu/h) | 33400 |
Heating Capacity at 5°F (Btu/h) | 33600 |
COP at 5°F | 1.75 |
Installation Capabilities | Automatic system discovery,Test mode for manual measurements,Preprogrammed system tests |
Compressor Staging | Continuously variable |
Refrigerant Type | R-410A |
Refrigerant with GWP | R-410A (GWP:2088) |
Connected Capable | No |
Date Available on Market | 09/24/2022 |
Date Certified | 03/10/2023 |
Markets | United States, Canada |
CB Model Identifier | ES_1023593_AC030BXSCCH_01302023171001_8136025 |
AHRI Reference Number | 207698070 |
Tax Credit Eligible | Yes |
Meets ENERGY STAR Most Efficient 2023 Criteria | Yes |
ENERGY STAR Certified Products - Non-lighting
Device Name | Model Number | Company | Certification Date |
---|---|---|---|
HP - Mini or Multi Split | AC030BXSCCH | Samsung | 2023-03-10 |
Descriptor | Details |
---|---|
Partner Name | Samsung Electronics Co., Ltd. |
Product Category | Central Air Conditioners and Air Source Heat Pumps |
Model Name | Duct S (HSP) Max Heat |
Updated On | 2024-03-28 |
Last Update | 2024-03-29 |
CB Model Identifier | 09/24/2022 12:00:00 AM |
ENERGY STAR Certified Mini-Split Heat Pumps
Device Name | Model Number | Company | Certification Date |
---|---|---|---|
HP - Mini or Multi Split | 2023-03-10 |
Descriptor | Details |
---|---|
Partner Name | Samsung Electronics Co., Ltd. |
Updated On | 2024-03-28 |
Last Update | 2024-03-29 |
Manufacturer Type | System Manufacturer |
Series Name | Duct S (HSP) Max Heat |
Outdoor Unit Brand Name | Samsung |
Outdoor Unit Model Number | AC030BXSCCH |
Indoor Unit Brand Name | SAMSUNG |
Indoor Unit Model Number | AC030BNHDCH |
Cold Climate | Yes |
Meets Peak Cooling Requirements | Yes |
SEER2 (Btu/Wh) | 18.7 |
EER2 (Btu/Wh) | 12 |
HSPF2 (Btu/Wh) | 8.6 |
Cooling Capacity (Btu/h) | 30000 |
Heating Capacity at 47°F (Btu/h) | 32000 |
Heating Capacity at 17°F (Btu/h) | 33400 |
Heating Capacity at 5°F (Btu/h) | 33600 |
COP at 5°F | 1.75 |
Installation Capabilities | Automatic system discovery,Test mode for manual measurements,Preprogrammed system tests |
Compressor Staging | Continuously variable |
Refrigerant Type | R-410A |
Refrigerant with GWP | R-410A (GWP:2088) |
Connected Capable | No |
Date Available on Market | 09/24/2022 |
Date Certified | 03/10/2023 |
Markets | United States, Canada |
CB Model Identifier | ES_1023593_AC030BXSCCH_01302023171001_8136025 |
AHRI Reference Number | 207698070 |
Tax Credit Eligible | Yes |
Meets ENERGY STAR Most Efficient 2023 Criteria | Yes |
ENERGY STAR Most Efficient Mini-Split Heat Pumps
Device Name | Model Number | Company | Certification Date |
---|---|---|---|
HP - Mini or Multi Split | 2023-03-10 |
Descriptor | Details |
---|---|
Partner Name | Samsung Electronics Co., Ltd. |
Updated On | 2024-03-28 |
Last Update | 2024-03-29 |
Manufacturer Type | System Manufacturer |
Series Name | Duct S (HSP) Max Heat |
Outdoor Unit Brand Name | Samsung |
Outdoor Unit Model Number | AC030BXSCCH |
Indoor Unit Brand Name | SAMSUNG |
Indoor Unit Model Number | AC030BNHDCH |
Cold Climate | Yes |
Meets Peak Cooling Requirements | Yes |
SEER2 (Btu/Wh) | 18.7 |
EER2 (Btu/Wh) | 12 |
HSPF2 (Btu/Wh) | 8.6 |
Cooling Capacity (Btu/h) | 30000 |
Heating Capacity at 47°F (Btu/h) | 32000 |
Heating Capacity at 17°F (Btu/h) | 33400 |
Heating Capacity at 5°F (Btu/h) | 33600 |
COP at 5°F | 1.75 |
Installation Capabilities | Automatic system discovery,Test mode for manual measurements,Preprogrammed system tests |
Compressor Staging | Continuously variable |
Refrigerant Type | R-410A |
Refrigerant with GWP | R-410A (GWP:2088) |
Connected Capable | No |
Date Available on Market | 09/24/2022 |
Date Certified | 03/10/2023 |
Markets | United States, Canada |
CB Model Identifier | ES_1023593_AC030BXSCCH_01302023171001_8136025 |
AHRI Reference Number | 207698070 |
Tax Credit Eligible | No |
Meets ENERGY STAR Most Efficient 2023 Criteria | Yes |
The Energy Star Logo is a registered trademark of the U.S. EPA.
Documents - samsung electronics,Samsung Electronics Co., Ltd.,Samsung – AC030BXSCCH
[pdf]
User Manual Troubleshooting Guide Parts List Specifications Diagram
SERVICE MANUAL CAC AC B DCHAA 00286E 2 220107 samsung files s3 amazonaws Tech Files Service Manuals ||| SYSTEM AIR CONDITIONER SINGLE for North America R-410A, Heat Pump and Cooling Only INDOOR UNIT O ... DCH AC030BXADCH AC036BXADCH AC042BXADCH AC048BXADCH AC018BXSCCC AC024BXSCCC AC030BXSCCC AC036BXSCCC AC030BXSCCH AC036BXSCCH AIR CONDITIONER CONTENTS 1. Precautions 2. Product Specifications 3. Disas... lang:en score:30 filesize: 14.3 M page_count: 330 document date: 0000-00-00 | |
[pdf]
User Manual Troubleshooting Guide Parts List Specifications Diagram
SERVICE MANUAL CAC AC B DCHAA 00286E 2 220107 samsung files s3 amazonaws Tech Files Service Manuals ||| SYSTEM AIR CONDITIONER SINGLE for North America R-410A, Heat Pump and Cooling Only INDOOR UNIT O ... DCH AC030BXADCH AC036BXADCH AC042BXADCH AC048BXADCH AC018BXSCCC AC024BXSCCC AC030BXSCCC AC036BXSCCC AC030BXSCCH AC036BXSCCH AIR CONDITIONER CONTENTS 1. Precautions 2. Product Specifications 3. Disas... lang:en score:30 filesize: 14.3 M page_count: 330 document date: 0000-00-00 | |
[pdf]
SAMSUNG SAC SCCR Data Book Ver 1 3 10112023A samsung files s3 amazonaws Tech Files Bulletins Rating ||| AA U9 DVM S, DVM S2, RAC, CAC, FJM, HylexTM SCCR Short Circuit Current Rating Data DVM S and DV ... BXADCH/AA AC018BXADCH/AA AC024BXADCH/AA AC030BXADCH/AA AC036BXADCH/AA AC042BXADCH/AA AC048BXADCH/AA AC030BXSCCH/AA AC036BXSCCH/AA AC018BXSCCC/AA AC024BXSCCC/AA AC030BXSCCC/AA AC036BXSCCC/AA AC024BXUPC... lang:tl score:28 filesize: 1.63 M page_count: 4 document date: 0000-00-00 | |
[pdf]
User Manual Accessories
CAC 18 48K Standard Max Heat 40 CO Outdoor Installation Manual DB68 11274A 01 211209 D04 ENGLISH samsung files s3 amazonaws Tech Files Units Manuals ||| Air conditioner Installation manual AC***BX**C* Thank you for purchasing this Samsung air condition ... fall. In addition, install a snow-proof hood to avoid snow from piling on the outdoor unit. D Type AC030BXSCCH, AC036BXSCCH 37.01 940 24.41 620 54.92 1395 Snow-proof hood 55.91 1420 25.1... lang:en score:27 filesize: 2.76 M page_count: 40 document date: 0000-00-00 | |
[pdf]
Specifications Dimension Guide
AC030BNZDCH CNH30ZDB AC030BXSCCH CXH30SCB Submittal CAC Single Zone MAX HEAT MPAH 2301A samsung files s3 amazonaws Tech Files AC0 BNZDCHAA Submittals ||| SUBMITTAL AC030BNZDCH/AA / AC030BXSCCH/AA CNH30ZDB / CXH30SCB Page 1 of 4 Samsung Max Heat, Low Ambient Heating, Multi-position Air Handler, Single Zone, Split System Job Name Purchaser Submitted to Unit Designation Model Specifications Indoor Unit Model Number US Code Outdoor Unit Model Numb... lang:en score:26 filesize: 2.82 M page_count: 4 document date: 2023-01-18 | |
[pdf]
Specifications Dimension Guide
AC030BNZDCH CNH30ZDB AC030BXSCCH CXH30SCB Submittal CAC Single Zone MAX HEAT MPAH 2211B samsung files s3 amazonaws Tech Files AC0 BNZDCHAA Submittals ||| SUBMITTAL AC030BNZDCH/AA / AC030BXSCCH/AA CNH30ZDB / CXH30SCB Page 1 of 4 Samsung Max Heat, Low Ambient Heating, Multi-position Air Handler, Single Zone, Split System Job Name Purchaser Submitted to Unit Designation Model Specifications Indoor Unit Model Number US Code Outdoor Unit Model Numb... lang:en score:26 filesize: 2.52 M page_count: 4 document date: 2022-11-29 | |
[pdf]
Specifications Dimension Guide
AC030BNHDCH CNH30HDB AC030BXSCCH CXH30SCB Submittal CAC Single Zone MAX HEAT Duct S 05052022 samsung files s3 amazonaws Tech Files AC0 BNHDCHAA Submittals ||| SUBMITTAL AC030BNHDCH/AA / AC030BXSCCH/AA CNH30HDB / CXH30SCB Page 1 of 4 Samsung Max Heat, Low Ambient Heating, Duct S, Single Zone Duct, Split System Job Name Purchaser Submitted to Unit Designation Location Engineer Reference Schedule # Approval Construction Model Performance 1 Specificat... lang:en score:26 filesize: 2.55 M page_count: 4 document date: 0000-00-00 | |
[pdf]
Specifications Dimension Guide
AC030BNHDCH CNH30HDB AC030BXSCCH CXH30SCB Submittal CAC Single Zone MAX HEAT Duct S 06072022 samsung files s3 amazonaws Tech Files AC0 BNHDCHAA Submittals ||| SUBMITTAL AC030BNHDCH/AA / AC030BXSCCH/AA CNH30HDB / CXH30SCB Page 1 of 4 Samsung Max Heat, Low Ambient Heating, Duct S, Single Zone Duct, Split System Job Name Purchaser Submitted to Unit Designation Location Engineer Reference Schedule # Approval Construction Model Performance 1 Specificat... lang:en score:26 filesize: 2.99 M page_count: 4 document date: 0000-00-00 | |
[pdf]
Specifications Dimension Guide
AC030BNHDCH CNH30HDB AC030BXSCCH CXH30SCB Submittal CAC Single Zone MAX HEAT Duct S 2212A samsung files s3 amazonaws Tech Files AC0 BNHDCHAA Submittals ||| SUBMITTAL AC030BNHDCH/AA / AC030BXSCCH/AA CNH30HDB / CXH30SCB Page 1 of 4 Samsung Max Heat, Low Ambient Heating, Duct S, Single Zone Duct, Split System Job Name Purchaser Submitted to Unit Designation Model Specifications Indoor Unit Model Number US Code Outdoor Unit Model Number US Code P... lang:en score:26 filesize: 5.04 M page_count: 4 document date: 2022-12-12 | |
[pdf]
Specifications Dimension Guide
AC030BNHDCH CNH30HDB AC030BXSCCH CXH30SCB Submittal CAC Single Zone MAX HEAT Duct S 02142022 samsung files s3 amazonaws Tech Files AC0 BNHDCHAA Submittals ||| SUBMITTAL AC030BNHDCH/AA / AC030BXSCCH/AA CNH30HDB / CXH30SCB Page 1 of 4 Samsung Max Heat, Low Ambient Heating, Duct S, Single Zone Duct, Split System Job Name Purchaser Submitted to Unit Designation Location Engineer Reference Schedule # Approval Construction Model Performance 1 Specificat... lang:en score:26 filesize: 2.38 M page_count: 4 document date: 0000-00-00 | |
[pdf]
Specifications Dimension Guide
AC030KNZDCH CNH30ZDK AC030BXSCCH CXH30SCB Submittal CAC Single Zone MAX HEAT MPAH 05052022 samsung files s3 amazonaws Tech Files AC KNZDCH Multi position Submittals 2021 ||| SUBMITTAL AC030KNZDCH/AA / AC030BXSCCH/AA CNH30ZDK / CXH30SCB Page 1 of 4 Samsung Max Heat, Low Ambient Heating, Multi-position Air Handler, Single Zone, Split System Job Name Purchaser Submitted to Unit Designation Location Engineer Reference Schedule # Approval Construction Model Performanc... lang:en score:26 filesize: 2.47 M page_count: 4 document date: 0000-00-00 | |
[pdf]
Specifications Dimension Guide
AC030KNZDCH CNH30ZDK AC030BXSCCH CXH30SCB Submittal CAC Single Zone MAX HEAT MPAH 06072022 samsung files s3 amazonaws Tech Files AC KNZDCH Multi position Submittals 2021 ||| SUBMITTAL AC030KNZDCH/AA / AC030BXSCCH/AA CNH30ZDK / CXH30SCB Page 1 of 4 Samsung Max Heat, Low Ambient Heating, Multi-position Air Handler, Single Zone, Split System Job Name Purchaser Submitted to Unit Designation Location Engineer Reference Schedule # Approval Construction Model Performanc... lang:en score:26 filesize: 2.6 M page_count: 4 document date: 2022-06-10 | |
[pdf]
Specifications Dimension Guide
AC030KNZDCH CNH30ZDK AC030BXSCCH CXH30SCB Submittal CAC Single Zone MAX HEAT MPAH 02142022 samsung files s3 amazonaws Tech Files AC KNZDCH Multi position Submittals 2021 ||| SUBMITTAL AC030KNZDCH/AA / AC030BXSCCH/AA CNH30ZDK / CXH30SCB Page 1 of 4 Samsung Max Heat, Low Ambient Heating, Multi-position Air Handler, Single Zone, Split System Job Name Purchaser Submitted to Unit Designation Location Engineer Reference Schedule # Approval Construction Model Performanc... lang:en score:26 filesize: 2.26 M page_count: 4 document date: 0000-00-00 | |
[pdf]
Specifications Dimension Guide
AC030BN4DCH CNH304DB AC030BXSCCH CXH30SCB Submittal CAC Single Zone MAX HEAT WF 4 Way Cassette 06072022 samsung files s3 amazonaws Tech Files AC0 BN4DCHAA Submittals ||| Job Name Purchaser Submitted to Unit Designation SUBMITTAL AC030BN4DCH/AA, AC030BXSCCH/AA CNH304DB/CXH30SCB Page 1 of 4 Samsung Max Heat, WindFreeTM*, Low Ambient Heating, 4-Way Cassette, Single Zone, Split System Location Engineer Reference Schedule # Approval Construction Model Specifica... lang:en score:25 filesize: 4.16 M page_count: 4 document date: 2022-06-10 | |
[pdf]
Specifications Dimension Guide
AC030BN4DCH CNH304DB AC030BXSCCH CXH30SCB Submittal CAC Single Zone MAX HEAT WF 4 Way Cassette 04072022 samsung files s3 amazonaws Tech Files AC0 BN4DCHAA Submittals ||| Job Name Purchaser Submitted to Unit Designation SUBMITTAL AC030BN4DCH/AA, AC030BXSCCH/AA CNH304DB/CXH30SCB Page 1 of 4 Samsung Max Heat, WindFreeTM*, Low Ambient Heating, 4-Way Cassette, Single Zone, Split System Location Engineer Reference Schedule # Approval Construction Model Specifica... lang:en score:25 filesize: 2.95 M page_count: 4 document date: 0000-00-00 | |
[pdf]
Specifications Dimension Guide
AC030BN4DCH CNH304DB AC030BXSCCH CXH30SCB Submittal CAC Single Zone MAX HEAT WF 4 Way Cassette 2212A samsung files s3 amazonaws Tech Files AC0 BN4DCHAA Submittals ||| SUBMITTAL AC030BN4DCH/AA, AC030BXSCCH/AA CNH304DB/CXH30SCB Page 1 of 4 Samsung Max Heat, WindFreeTM*, Low Ambient Heating, 4-Way Cassette, Single Zone, Split System Job Name Purchaser Submitted to Unit Designation Model Specifications Indoor Unit Model Number US Code Outdoor Unit Model Numb... lang:en score:25 filesize: 5.74 M page_count: 4 document date: 2022-12-13 | |
[pdf]
User Manual
CAC 18 48K Standard Max Heat 40 CO Outdoor Installation Manual DB68 11274A 01 211209 D04 SPANISH samsung files s3 amazonaws Tech Files Units Manuals ||| Aire acondicionado Manual de instalacin AC***BX**C* Gracias por comprar este aire acondicionado Sam ... 0 24,41 620 21,97 558 22,32 567 26,57 675 12,99 330 47,64 1210 46,65 1185 Tipo D AC030BXSCCH, AC036BXSCCH 37,01 940 24,41 620 55,91 1420 Cubierta antinieve Cada de nieve es... lang:es score:25 filesize: 2.77 M page_count: 40 document date: 0000-00-00 | |
[pdf]
Specifications Dimension Guide
AC030BN4DCH CNH304DB AC030BXSCCH CXH30SCB Submittal CAC Single Zone MAX HEAT WF 4 Way Cassette 02152022 samsung files s3 amazonaws Tech Files AC0 BN4DCHAA Submittals ||| Job Name Purchaser Submitted to Unit Designation SUBMITTAL AC030BN4DCH/AA, AC030BXSCC/AA CNH304DB/ ... f 4 Samsung Max Heat, WindFreeTM*, Low Ambient Heating, 4-Way Cassette, Single Zone, Split System AC030BXSCCH/AA Dimensional Drawing Units: Inches 37 1 3/8 13 1 3/8 22 7/8 12 5/16 20 11/16 6 ... lang:en score:21 filesize: 2.92 M page_count: 4 document date: 0000-00-00 | |
[pdf]
Specifications Dimension Guide
AC030BN4DCH CNH304DB AC030BXSCCH CXH30SCB Submittal CAC Single Zone MAX HEAT WF 4 Way Cassette 03242022 samsung files s3 amazonaws Tech Files AC0 BN4DCHAA Submittals ||| Job Name Purchaser Submitted to Unit Designation SUBMITTAL AC030BN4DCH/AA, AC030BXSCC/AA CNH304DB/ ... f 4 Samsung Max Heat, WindFreeTM*, Low Ambient Heating, 4-Way Cassette, Single Zone, Split System AC030BXSCCH/AA Dimensional Drawing Units: Inches 37 1 3/8 13 1 3/8 22 7/8 12 5/16 20 11/16 6 ... lang:en score:21 filesize: 3.02 M page_count: 4 document date: 0000-00-00 | |
[pdf]
Specifications
TDB 2021 CAC Max Heat 4 WAY MPAH Duct S ver 1 2 220905 samsung files s3 amazonaws Tech Files AC0 BXSCCHAA 2022 ||| SINGLE Technical Data Book Max Heat Line up for America R410A, HP Model : CNH**4DB AC***BN4DCH/AA ... z EA m3/min ft/min l/s In Wg W x n , mm dB A dB A kg lbs kg lbs mm inch mm inch AC030BN4DCH/AA AC030BXSCCH/AA CNH304DB CXH30SCB Heat Pump 3.81/8.79/10.55 13,000 / 30,000 / 36,000 1.08/2.50/3.00 2... lang:en score:20 filesize: 20.59 M page_count: 96 document date: 0000-00-00 | |
[pdf]
TDB 2021 Single Max Heat Line up for America R410A HP ver 1 0 211223 samsung files s3 amazonaws Tech Files CAC AC0 BXSCCHAA 2022 ||| SINGLE Technical Data Book Max Heat Line up for America R410A, HP Model : CNH**4DB AC***BN4DCH/AA ... z EA m3/min ft/min l/s In Wg W x n , mm dB A dB A kg lbs kg lbs mm inch mm inch AC030BN4DCH/AA AC030BXSCCH/AA CNH304DB CXH30SCB Heat Pump 3.81/8.79/10.55 13,000 / 30,000 / 36,000 1.08/2.50/3.00 2... lang:en score:20 filesize: 27.41 M page_count: 96 document date: 2022-01-14 | |
[pdf]
TDB 2021 CAC Max Heat 4 WAY MPAH Duct S ver 1 0 221216 samsung files s3 amazonaws Tech Files AC0 BXSCCHAA 2022 ||| SINGLE Technical Data Book Max Heat Line up for America R410A, HP Model : CNH**4DB AC***BN4DCH/AA ... z EA m3/min ft/min l/s In Wg W x n , mm dB A dB A kg lbs kg lbs mm inch mm inch AC030BN4DCH/AA AC030BXSCCH/AA CNH304DB CXH30SCB Heat Pump 3.81/8.79/10.55 13,000 / 30,000 / 36,000 1.08/2.50/3.00 2... lang:en score:19 filesize: 21.41 M page_count: 96 document date: 0000-00-00 | |
[pdf]
TDB 2021 CAC Max Heat 4 WAY MPAH Duct S ver 1 0 221216B samsung files s3 amazonaws Tech Files AC0 BXSCCHAA 2022 ||| SINGLE Technical Data Book Max Heat Line up for America R410A, HP Model : CNH**4DB AC***BN4DCH/AA ... z EA m3/min ft/min l/s In Wg W x n , mm dB A dB A kg lbs kg lbs mm inch mm inch AC030BN4DCH/AA AC030BXSCCH/AA CNH304DB CXH30SCB Heat Pump 3.81/8.79/10.55 13,000 / 30,000 / 36,000 1.08/2.50/3.00 2... lang:en score:19 filesize: 21.43 M page_count: 96 document date: 2023-02-01 | |
[pdf]
Parts List Specifications
AC030BXSCCHAA Exploded View Parts List map 01212022 samsung files s3 amazonaws Tech Files CAC Outdoor Units Views ||| 1. AC030BXSCCH/AA AC030BXSCCH/AA Exploded View Exploded Views and Parts List Parts List No. 1 Lvl. Loc. 2 2 2 2-1 3 2-2 3 2-3 3 2-4 3 A0092 2-5 3 A2609 Material Code DB92-05178A DB90-12356A DB63-02729D DB64-03527A DB64-03526A DB90-12252A DB90-05905G Description Specification ASS... lang:en score:18 filesize: 6.59 M page_count: 5 document date: 0000-00-00 | |
[pdf]
82306 Samsung Qualifiying Model List 1 res cloudinary govimg image upload v1683655041 5b294f9467c0d0489028b276 ||| Inflation Reduction Act Rebates and Tax Credit Qualifying Product List High Efficiency Electric Home ... Cassette WindFreeTM Ductless AC048BXADCH 207698065 4-Way Cassette WindFreeTM Max Heat Ductless AC030BXSCCH 207698071 4-Way Cassette WindFreeTM Max Heat Ductless AC036BXSCCH 207465447 High-Wa... lang:en score:18 filesize: 279.76 K page_count: 2 document date: 2023-05-04 | |
[pdf]
Specifications Accessories
Samsung Hail Guard Kit Submittal 07292022A samsung files s3 amazonaws Tech Files Accessories Guards ||| SUBMITTAL Hail Guard Kits for Side Discharge Units HGK-* Page 1 of 3 Job Name Purchaser Submitte ... DCH/AA CXH30ADB AC036BXADCH/AA CXH36ADB AC042BXADCH/AA CXH42ADB AC048BXADCH/AA CXH48ADB CAC Max AC030BXSCCH/AA CXH30SCB Heat AC036BXSCCH/AA CXH36SCB AC018BXSCCC/AA CXC18SCB CAC -40 AC024BXSCCC... lang:en score:17 filesize: 2.15 M page_count: 3 document date: 2022-08-08 | |
[pdf]
Technical Bulletin
TB2022 0002 CAC FJM Outdoor Unit Coil Type and Salt Spray Test Method 03092022 samsung files s3 amazonaws Tech Files Bulletins RAC ||| TECHNICAL BULLETIN 2022-0002 Date: 03/07/2022 Subject: CAC/FJM Outdoor Unit Coil Type and Salt Spray ... BXADCH/AA AC042BXADCH/AA AC048BXADCH/AA AC018BXSCCC/AA AC024BXSCCC/AA AC030BXSCCC/AA AC036BXSCCC/AA AC030BXSCCH/AA AC036BXSCCH/AA AC009BXADCH/AA AC012BXADCH/AA AJ020BXJ2CH/AA AJ024BXJ3CH/AA AJ036BXJ4C... lang:en score:16 filesize: 91.35 K page_count: 1 document date: 0000-00-00 | |
[pdf]
Specifications Accessories
WB M B Submittal Samsung Metal Wind Baffle 04172023 samsung files s3 amazonaws Tech Files Accessories Baffles horizontal discharge ||| Job Name Purchaser Submitted to Unit Designation Wind Baffle Project Selection Model WBF-1M2 WBF-2 ... Cooling AC030BXSCCC/AA CXC30SCB WBF-2M-B WBB-3M AC036BXSCCC/AA CXC36SCB WBF-2M-B WBB-3M CAC Max AC030BXSCCH/AA CXH30SCB WBF-6M WBB-4M Heat AC036BXSCCH/AA CXH36SCB WBF-6M WBB-4M AR09BSFCMWKXCV R... lang:en score:16 filesize: 1.09 M page_count: 7 document date: 2023-04-18 | |
[pdf]
Technical Bulletin
TB2020 0023 Reduced Unit Installation Clearance rev 04172023 samsung files s3 amazonaws Tech Files Bulletins RAC CAC FJM ||| TECHNICAL BULLETIN 2020-0023 Date: 07/21/2020 Subject: Reduced Unit Installation Clearance for Side ... SFACWKXCV AR24TSFACWKXCV AR36BSHUMGMXCV AC018BXSCCC/AA AC024BXSCCC/AA AC030BXSCCC/AA AC036BXSCCC/AA AC030BXSCCH/AA AC036BXSCCH/AA AC030JXSCCH/AA AC036JXSCCH/AA US Code RXS09CMC RXS12CMC RXS15CMC RXS1... lang:en score:16 filesize: 773.33 K page_count: 3 document date: 0000-00-00 | |
[pdf]
Technical Bulletin
TB2022 0004 CAC 24K and 36K Mixed Generation Match Option Settings 04192022 samsung files s3 amazonaws Tech Files Bulletins RAC FJM ||| TECHNICAL BULLETIN 2022-0004 Date: 04/19/2022 Subject: CAC New Model / Previous Model Unit Match Opt ... ode Number K Btu/h US Code 24 AC024BXADCH/AA CXH24ADB 36 AC036BXADCH/AA CXH36ADB 36 AC030BXSCCH/AA CXH30SCB 24 AC024BXSCCC/AA CXC24SCB 36 AC036BXSCCC/AA CXC36SCB Indoor Unit... lang:en score:16 filesize: 143.62 K page_count: 1 document date: 0000-00-00 | |
[pdf]
TDB 2021 CAC Max Heat 4 WAY MPAH Duct S ver 1 220207 samsung files s3 amazonaws Tech Files AC0 BXSCCHAA 2022 ||| SINGLE Technical Data Book 5 1 2-#,/* / S 98ET Model : BB SBBB MTEBBSBBBMTEBBSBBBMT BBSBBBMT H ... current of the power conversion MCA A MOP A equipment FAN1 A FAN2 A FAN A AC030BN4DCH AC030BXSCCH AC030BNHDCH AC030BNZDCH 21.0 1.25 1.25 AC030KNZDCH AC036BN4DCH AC036BXSCCH AC03... lang:en score:11 filesize: 10 M page_count: 96 document date: 0000-00-00 | |
[pdf]
TDB 2021 CAC Max Heat 4 WAY MPAH Duct S ver 1 0 211223 samsung files s3 amazonaws Tech Files AC0 BXSCCHAA 2022 ||| SINGLE Technical Data Book 5 1 2-#,/* / S 98ET Model : BB SBBB MTEBBSBBBMTEBBSBBBMT BBSBBBMT H ... current of the power conversion MCA A MOP A equipment FAN1 A FAN2 A FAN A AC030BN4DCH AC030BXSCCH AC030BNHDCH AC030BNZDCH 21.0 1.25 1.25 AC030KNZDCH AC036BN4DCH AC036BXSCCH AC03... lang:en score:10 filesize: 10 M page_count: 96 document date: 2022-02-04 |