Electric Vehicle Supply Equipment - Star Charge

Specifications & Energy Star Certification #3626835

EnergyStar Certifications

ENERGY STAR Certified Products - Non-lighting

Device Name Model Number Company Certification Date
DC Output Electric Vehicle Supply EquipmentDC1800AN147###Star Charge2024-08-30
Certification Description
 This data set contains a simplified list of all currently certified ENERGY STAR Non-lighting models with basic model information collected across all product categories including ENERGY STAR Unique IDs, ENERGY STAR partners, model names and numbers, and brand names. Learn more about ENERGY STAR products at www.energystar.gov/products. A full list of ENERGY STAR specifications can be found at www.energystar.gov/specifications.
Descriptor Details
Partner NameStar Charge Americas Corp
Product CategoryElectric Vehicle Supply Equipment
Model NameElectric Vehicle Supply Equipment
Other Model Details,,#=0-2 represents the different rated output current,0=400A,1=380A,2=400A+380A,#=1-3 represents the different DC connector deploy,1=With two Connectors,2=Only Left,3=Only Right,#=1-2 represents with or without POS terminal,1=with pos terminal
Updated On2024-09-18
Last Update2024-09-19
Date Available On Market07/08/2024 12:00:00 AM
Date Certified08/30/2024 12:00:00 AM
MarketsUnited States, Canada
CB Model IdentifierES_1150661_DC1800AN147###_08302024101710_1010101
Meets ENERGY STAR Most Efficient 2024No


ENERGY STAR Certified Electric Vehicle Supply Equipment - DC-Output

Device Name Model Number Company Certification Date
DC1800AN147###Star Charge2024-08-30
Certification Description
 Certified models meet all ENERGY STAR requirements for DC-output models as listed in the Version 1.1 ENERGY STAR Program Requirements for Electric Vehicle Supply Equipment that are effective as of March 31, 2021 or the V1.2 ENERGY STAR Program Requirements that are effective as of June 20, 2023. A detailed listing of key efficiency criteria are available at https://www.energystar.gov/products/evse_key_product_criteria.
Descriptor Details
Partner NameStar Charge Americas Corp
Model NameElectric Vehicle Supply Equipment
Other Model Details,,#=0-2 represents the different rated output current,0=400A,1=380A,2=400A+380A,#=1-3 represents the different DC connector deploy,1=With two Connectors,2=Only Left,3=Only Right,#=1-2 represents with or without POS terminal,1=with pos terminal
Updated On2024-09-18
Last Update2024-09-19
DC-input or AC-inputAC-input
Single Phase or Three PhaseThree Phase
Product ConfigurationDistributed Product Configuration
Connector TypeCombined Charging System (CCS)
Network CapabilityYes
Network Connection Types AvailableGigabit Ethernet,Wi-Fi,Cellular
Output Cord Length (ft.)0
Output Cord Gauge (AWG)1
Automatic Brightness Control Capable?No
Connected CapableNo
Auxiliary Product FeaturesHigh Resolution Display,Credit Card Reader,Radio Frequency Identification (RFID)
Product FeaturesNone
Maximum Available Output Power180000
Maximum Nameplate Output Current (A) AC-Input500
Rated Input Voltage (V) AC-Input480
Number of Outputs2
Integral Battery BankNo
No Vehicle Mode Input Power (watts) AC-Input54.6
No Vehicle Mode Total Allowance (watts)136.57
No Vehicle Mode Power Factor AC-Input0.01
Partial On Mode Input Power (watts) AC-Input55.6
Partial On Mode Total Allowance (watts)136.57
Partial On Mode Power Factor AC-Input0.01
Idle Mode Input Power (watts) AC- Input168.3
Idle Mode Power Factor AC-Input0.02
Operation Mode: 25% Loading Condition Input Power in Cold Climate AC-Input46320
Operation Mode: 25% Loading Condition Output Power in Cold Climate AC-Input44607
Operation Mode: 50% Loading Condition Input Power in Cold Climate AC-Input92317
Operation Mode: 50% Loading Condition Output Power in Cold Climate AC-Input89341
Operation Mode: 75% Loading Condition Input Power in Cold Climate AC-Input138371
Operation Mode: 75% Loading Condition Output Power in Cold Climate AC-Input134167
Operation Mode: 50 kW Loading Condition Input Power in Cold Climate AC-Input51287
Operation Mode: 50 kW Loading Condition Output Power in Cold Climate AC-Input49478
Operation Mode: 150 kW Loading Condition Input Power in Cold Climate AC-Input153336
Operation Mode: 150 kW Loading Condition Output Power in Cold Climate AC-Input148759
Operation Mode: 100% Loading Condition Input Power in Cold Climate AC-Input184265
Operation Mode: 100% Loading Condition Output Power in Cold Climate AC-Input178591
Operation Mode: 100% Loading Condition Power Factor in Cold Climate AC-Input0.99
Operation Mode: 25% Loading Condition Input Power in Temperate Climate AC-Input51236
Operation Mode: 25% Loading Condition Output Power in Temperate Climate AC-Input49425
Operation Mode: 50% Loading Condition Input Power in Temperate Climate AC-Input92187
Operation Mode: 50% Loading Condition Output Power in Temperate Climate AC-Input89220
Operation Mode: 75% Loading Condition Input Power in Temperate Climate AC-Input138151
Operation Mode: 75% Loading Condition Output Power in Temperate Climate AC-Input133952
Operation Mode: 50 kW Loading Condition Input Power in Temperate Climate AC-Input51236
Operation Mode: 50 kW Loading Condition Output Power in Temperate Climate AC-Input49425
Operation Mode: 150 kW Loading Condition Input Power in Temperate Climate AC-Input153224
Operation Mode: 150 kW Loading Condition Output Power in Temperate Climate AC-Input148654
Operation Mode: 100% Loading Condition Input Power in Temperate Climate AC-Input184016
Operation Mode: 100% Loading Condition Output Power in Temperate Climate AC-Input178333
Operation Mode: 100% Loading Condition Power Factor in Temperate Climate AC-Input0.99
Operation Mode: 25% Loading Condition Input Power in Hot Climate AC-Input47107
Operation Mode: 25% Loading Condition Output Power in Hot Climate AC-Input44381
Operation Mode: 50% Loading Condition Input Power in Hot Climate AC-Input92367
Operation Mode: 50% Loading Condition Output Power in Hot Climate AC-Input89092
Operation Mode: 75% Loading Condition Input Power in Hot Climate AC-Input137920
Operation Mode: 75% Loading Condition Output Power in Hot Climate AC-Input133661
Operation Mode: 50 kW Loading Condition Input Power in Hot Climate AC-Input52095
Operation Mode: 50 kW Loading Condition Output Power in Hot Climate AC-Input49328
Operation Mode: 150 kW Loading Condition Input Power in Hot Climate AC-Input152734
Operation Mode: 150 kW Loading Condition Output Power in Hot Climate AC-Input147957
Operation Mode: 100% Loading Condition Input Power in Hot Climate AC-Input183729
Operation Mode: 100% Loading Condition Output Power in Hot Climate AC-Input177866
Operation Mode: 100% Loading Condition Power Factor in Hot Climate AC-Input0.99
Average Loading-Adjusted Efficiency (%) AC-Input0.97
No Vehicle Mode Input Power (watts) DC-Input0
Partial On Mode Input Power (watts) DC-Input0
Idle Mode Input Power (watts) DC-Input0
Date Available On Market07/08/2024
Date Certified08/30/2024
MarketsUnited States, Canada
CB Model IdentifierES_1150661_DC1800AN147###_08302024101710_1010101


The Energy Star Logo is a registered trademark of the U.S. EPA.