ESIM EMC Test rapor taslagi

Sedat Eser

Test Report

Elo Touch Solutions, Inc. EMCM100C POS RBWEMCM100C RBWEMCM100C emcm100c

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 54 Pages, 3.15MB

Document DEVICE REPORTGetApplicationAttachment.html?id=7386310
DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
4.2.2 Test Setup
30MHz-1GHz Test Setup:
Above 1GHz Test Setup:

4.2.3 Test Procedure

Reference Rule

Chapter

Description

ANSI C63.26

5.5

Radiated emissions testing

The spectrum was scanned from 9 kHz to the 10th harmonic of the highest frequency generated within the equipment. Emissions below 18 GHz were measured at a 3 meter test distance. The EUT was tested in three orthogonal axes and in all possible test configurations and poisoning when measurement antenna is orented n both horizontal and vertical polarization, the worst case emissions was showed in the report. Radiated emissions were used the substitution method descried in ANSI/TIA-603-E-2016. Radiated emissions were measured with 100kHz RBW below 1GHz and 1MHz RBW above 1GHz. According to specification, the power of emissions shall be attenuated below the transmitter power (P) by a factor of
at least X + 10 log (P) dB. P in watts. The specification can be interpreted as an absolute limit when the specified
attenuation is actually subtracted from the maximum permissible transmitter power [i.e., 10 log P ­ {X + 10 log P}],
resulting in an absolute level of -X dBW [or (-X + 30) dBm].

Report no.: 2390387R-RF-US-P07V01

Page 42 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

4.2.4 Test Data
WCDMA Band2: Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 1:WCDMA band2 1852.4MHz

Page No.: 19
Time: 2024/03/21 - 08:11 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 131.850 352.040 576.110

Measure Level (dBm) -75.734 -71.095 -65.998

Reading Level (dBm) -97.514 -97.255 -97.608

Over Limit (dB) -62.734 -58.095 -52.998

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
21.780 26.160 31.610

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 43 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 1:WCDMA band2 1852.4MHz

Page No.: 20
Time: 2024/03/21 - 08:11 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

*

3

Frequency (MHz) 73.650 130.880 455.830

Measure Level (dBm) -74.343 -67.043 -68.692

Reading Level (dBm) -96.823 -96.283 -97.372

Over Limit (dB) -61.343 -54.043 -55.692

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
22.480 29.240 28.680

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 44 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 1:WCDMA band2 1852.4MHz

Page No.: 13
Time: 2024/03/21 - 08:11 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 3704.800 5557.200 7409.600

Measure Level (dBm) -60.674 -58.315 -53.769

Reading Level (dBm) -54.545 -56.674 -56.871

Over Limit (dB) -47.674 -45.315 -40.769

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-6.129 -1.641 3.102

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 45 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 1:WCDMA band2 1852.4MHz

Page No.: 14
Time: 2024/03/21 - 08:11 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 3704.800 5557.200 7409.600

Measure Level (dBm) -60.996 -57.219 -53.638

Reading Level (dBm) -54.778 -56.793 -56.499

Over Limit (dB) -47.996 -44.219 -40.638

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-6.218 -0.426 2.861

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 46 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

WCDMA Band4: Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 2:WCDMA band4 1712.4MHz

Page No.: 21
Time: 2024/03/21 - 08:11 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 141.550 237.580 403.450

Measure Level (dBm) -75.507 -69.485 -67.831

Reading Level (dBm) -99.207 -97.075 -95.951

Over Limit (dB) -62.507 -56.485 -54.831

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
23.700 27.590 28.120

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 47 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 2:WCDMA band4 1712.4MHz

Page No.: 22
Time: 2024/03/21 - 08:11 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 103.720 314.210 618.790

Measure Level (dBm) -69.490 -67.541 -64.728

Reading Level (dBm) -97.800 -94.421 -96.488

Over Limit (dB) -56.490 -54.541 -51.728

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
28.310 26.880 31.760

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 48 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 2:WCDMA band4 1712.4MHz

Page No.: 15
Time: 2024/03/21 - 08:11 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 3424.800 5137.200 6849.600

Measure Level (dBm) -62.595 -58.370 -55.509

Reading Level (dBm) -54.385 -57.129 -57.001

Over Limit (dB) -49.595 -45.370 -42.509

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-8.210 -1.241 1.492

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 49 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 2:WCDMA band4 1712.4MHz

Page No.: 16
Time: 2024/03/21 - 08:11 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 3424.800 5137.200 6849.600

Measure Level (dBm) -62.371 -57.404 -55.936

Reading Level (dBm) -54.309 -56.404 -57.458

Over Limit (dB) -49.371 -44.404 -42.936

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-8.062 -1.000 1.522

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 50 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

WCDMA Band5: Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 3:WCDMA band5 826.4MHz

Page No.: 23
Time: 2024/03/21 - 08:11 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 67.830 145.430 528.580

Measure Level (dBm) -71.697 -71.886 -67.332

Reading Level (dBm) -96.727 -96.266 -97.342

Over Limit (dB) -58.697 -58.886 -54.332

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
25.030 24.380 30.010

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 51 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 3:WCDMA band5 826.4MHz

Page No.: 24
Time: 2024/03/21 - 08:11 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

*

3

Frequency (MHz) 91.110 131.850 363.680

Measure Level (dBm) -69.611 -66.279 -68.733

Reading Level (dBm) -97.451 -95.639 -96.513

Over Limit (dB) -56.611 -53.279 -55.733

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
27.840 29.360 27.780

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 52 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 3:WCDMA band5 826.4MHz

Page No.: 17
Time: 2024/03/21 - 08:11 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 1652.800 2479.200 3305.600

Measure Level (dBm) -68.251 -65.156 -63.685

Reading Level (dBm) -55.983 -55.352 -55.169

Over Limit (dB) -55.251 -52.156 -50.685

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-12.268 -9.804 -8.516

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 53 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 3:WCDMA band5 826.4MHz

Page No.: 18
Time: 2024/03/21 - 08:11 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 1652.800 2479.200 3305.600

Measure Level (dBm) -67.583 -65.521 -63.272

Reading Level (dBm) -56.013 -55.901 -54.824

Over Limit (dB) -54.583 -52.521 -50.272

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-11.570 -9.620 -8.448

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 54 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

LTE Band2: Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 4:LTE band2 1850MHz

Page No.: 67
Time: 2024/03/21 - 08:13 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 64.920 126.030 448.070

Measure Level (dBm) -70.520 -77.005 -68.196

Reading Level (dBm) -96.130 -97.985 -96.836

Over Limit (dB) -57.520 -64.005 -55.196

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
25.610 20.980 28.640

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 55 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 4:LTE band2 1850MHz

Page No.: 68
Time: 2024/03/21 - 08:13 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

*

3

Frequency (MHz) 49.400 119.240 481.050

Measure Level (dBm) -75.060 -66.019 -67.098

Reading Level (dBm) -96.280 -96.069 -96.078

Over Limit (dB) -62.060 -53.019 -54.098

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
21.220 30.050 28.980

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 56 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 4:LTE band2 1850MHz

Page No.: 45
Time: 2024/03/21 - 08:11 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 3700.000 5550.000 7400.000

Measure Level (dBm) -60.157 -58.627 -53.324

Reading Level (dBm) -53.999 -57.018 -56.413

Over Limit (dB) -47.157 -45.627 -40.324

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-6.158 -1.609 3.089

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 57 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 4:LTE band2 1850MHz

Page No.: 46
Time: 2024/03/21 - 08:11 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 3700.000 5550.000 7400.000

Measure Level (dBm) -60.986 -57.664 -54.365

Reading Level (dBm) -54.788 -57.190 -57.236

Over Limit (dB) -47.986 -44.664 -41.365

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-6.198 -0.474 2.871

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 58 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

LTE Band4: Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 5:LTE band4 1710MHz

Page No.: 69
Time: 2024/03/21 - 08:13 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 94.990 191.990 540.220

Measure Level (dBm) -80.302 -71.160 -65.772

Reading Level (dBm) -97.512 -95.190 -96.172

Over Limit (dB) -67.302 -58.160 -52.772

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
17.210 24.030 30.400

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 59 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 5:LTE band4 1710MHz

Page No.: 70
Time: 2024/03/21 - 08:13 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 124.090 325.850 543.130

Measure Level (dBm) -66.055 -70.271 -64.219

Reading Level (dBm) -95.865 -97.081 -94.399

Over Limit (dB) -53.055 -57.271 -51.219

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
29.810 26.810 30.180

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 60 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 5:LTE band4 1710MHz

Page No.: 47
Time: 2024/03/21 - 08:11 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 3420.000 5130.000 6840.000

Measure Level (dBm) -62.140 -58.589 -55.085

Reading Level (dBm) -53.836 -57.573 -56.731

Over Limit (dB) -49.140 -45.589 -42.085

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-8.304 -1.016 1.646

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 61 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 5:LTE band4 1710MHz

Page No.: 48
Time: 2024/03/21 - 08:11 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 3420.000 5130.000 6840.000

Measure Level (dBm) -63.008 -57.417 -55.016

Reading Level (dBm) -54.898 -56.455 -56.632

Over Limit (dB) -50.008 -44.417 -42.016

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-8.110 -0.962 1.616

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 62 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

LTE Band5: Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 6:LTE band5 824MHz

Page No.: 71
Time: 2024/03/21 - 08:13 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 77.530 170.650 428.670

Measure Level (dBm) -76.008 -69.069 -66.017

Reading Level (dBm) -97.368 -93.379 -94.757

Over Limit (dB) -63.008 -56.069 -53.017

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
21.360 24.310 28.740

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 63 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 6:LTE band5 824MHz

Page No.: 72
Time: 2024/03/21 - 08:13 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 115.360 242.430 579.990

Measure Level (dBm) -67.319 -73.682 -66.305

Reading Level (dBm) -96.709 -96.632 -97.435

Over Limit (dB) -54.319 -60.682 -53.305

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
29.390 22.950 31.130

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 64 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 6:LTE band5 824MHz

Page No.: 49
Time: 2024/03/21 - 08:12 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 1648.000 2472.000 3296.000

Measure Level (dBm) -68.414 -65.005 -63.411

Reading Level (dBm) -55.940 -55.361 -54.855

Over Limit (dB) -55.414 -52.005 -50.411

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-12.474 -9.644 -8.556

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 65 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 6:LTE band5 824MHz

Page No.: 50
Time: 2024/03/21 - 08:12 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 1648.000 2472.000 3296.000

Measure Level (dBm) -66.842 -64.397 -63.392

Reading Level (dBm) -55.131 -54.789 -55.051

Over Limit (dB) -53.842 -51.397 -50.392

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-11.711 -9.608 -8.341

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 66 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

LTE Band12: Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 7:LTE band12 699MHz

Page No.: 75
Time: 2024/03/21 - 08:13 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 71.710 210.420 543.130

Measure Level (dBm) -73.669 -72.095 -66.529

Reading Level (dBm) -97.189 -95.315 -97.039

Over Limit (dB) -60.669 -59.095 -53.529

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
23.520 23.220 30.510

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 67 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 7:LTE band12 699MHz

Page No.: 76
Time: 2024/03/21 - 08:13 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 99.840 229.820 435.460

Measure Level (dBm) -68.519 -72.782 -67.912

Reading Level (dBm) -97.559 -95.902 -96.542

Over Limit (dB) -55.519 -59.782 -54.912

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
29.040 23.120 28.630

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 68 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 7:LTE band12 699MHz

Page No.: 53
Time: 2024/03/21 - 08:12 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 1398.000 2097.000 2796.000

Measure Level (dBm) -70.943 -65.788 -64.579

Reading Level (dBm) -57.584 -55.521 -55.337

Over Limit (dB) -57.943 -52.788 -51.579

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-13.359 -10.267 -9.242

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 69 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 7:LTE band12 699MHz

Page No.: 54
Time: 2024/03/21 - 08:12 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 1398.000 2097.000 2796.000

Measure Level (dBm) -69.144 -65.922 -64.210

Reading Level (dBm) -56.045 -56.284 -55.249

Over Limit (dB) -56.144 -52.922 -51.210

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-13.099 -9.638 -8.961

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 70 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

LTE Band13: Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 8:LTE band13 777MHz

Page No.: 77
Time: 2024/03/21 - 08:13 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 62.010 166.770 792.420

Measure Level (dBm) -71.232 -71.883 -61.925

Reading Level (dBm) -96.802 -95.963 -96.125

Over Limit (dB) -58.232 -58.883 -48.925

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
25.570 24.080 34.200

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 71 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 8:LTE band13 777MHz

Page No.: 78
Time: 2024/03/21 - 08:13 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 71.710 223.030 514.030

Measure Level (dBm) -75.907 -72.374 -65.519

Reading Level (dBm) -97.957 -95.294 -95.699

Over Limit (dB) -62.907 -59.374 -52.519

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
22.050 22.920 30.180

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 72 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 8:LTE band13 777MHz

Page No.: 55
Time: 2024/03/21 - 08:12 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 1554.000 2331.000 3108.000

Measure Level (dBm) -70.061 -64.983 -61.664

Reading Level (dBm) -56.573 -55.101 -53.804

Over Limit (dB) -57.061 -51.983 -48.664

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-13.488 -9.882 -7.860

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 73 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 8:LTE band13 777MHz

Page No.: 56
Time: 2024/03/21 - 08:12 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 1554.000 2331.000 3108.000

Measure Level (dBm) -70.442 -64.895 -62.271

Reading Level (dBm) -57.279 -55.356 -55.131

Over Limit (dB) -57.442 -51.895 -49.271

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-13.163 -9.539 -7.140

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 74 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

LTE Band17: Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 9:LTE band17 704MHz

Page No.: 79
Time: 2024/03/21 - 08:13 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 99.840 260.860 592.600

Measure Level (dBm) -80.282 -70.949 -65.569

Reading Level (dBm) -97.722 -95.819 -97.669

Over Limit (dB) -67.282 -57.949 -52.569

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
17.440 24.870 32.100

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 75 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 9:LTE band17 704MHz

Page No.: 80
Time: 2024/03/21 - 08:13 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 73.650 180.350 445.160

Measure Level (dBm) -74.905 -69.854 -68.499

Reading Level (dBm) -97.385 -94.124 -97.279

Over Limit (dB) -61.905 -56.854 -55.499

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
22.480 24.270 28.780

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 76 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 9:LTE band17 704MHz

Page No.: 57
Time: 2024/03/21 - 08:12 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 1408.000 2112.000 2816.000

Measure Level (dBm) -71.344 -65.669 -63.072

Reading Level (dBm) -57.944 -55.486 -54.078

Over Limit (dB) -58.344 -52.669 -50.072

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-13.400 -10.183 -8.994

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 77 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 9:LTE band17 704MHz

Page No.: 58
Time: 2024/03/21 - 08:12 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 1408.000 2112.000 2816.000

Measure Level (dBm) -70.249 -65.215 -62.975

Reading Level (dBm) -57.179 -55.494 -54.206

Over Limit (dB) -57.249 -52.215 -49.975

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-13.070 -9.721 -8.769

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 78 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

LTE Band25: Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 10:LTE band25 1850MHz

Page No.: 81
Time: 2024/03/21 - 08:13 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 118.270 220.120 376.290

Measure Level (dBm) -78.203 -73.178 -67.855

Reading Level (dBm) -98.333 -96.778 -95.225

Over Limit (dB) -65.203 -60.178 -54.855

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
20.130 23.600 27.370

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 79 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 10:LTE band25 1850MHz

Page No.: 82
Time: 2024/03/21 - 08:13 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 100.810 242.430 592.600

Measure Level (dBm) -69.106 -70.661 -65.679

Reading Level (dBm) -97.976 -93.611 -97.289

Over Limit (dB) -56.106 -57.661 -52.679

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
28.870 22.950 31.610

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 80 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 10:LTE band25 1850MHz

Page No.: 59
Time: 2024/03/21 - 08:12 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 3700.000 5550.000 7400.000

Measure Level (dBm) -60.740 -58.313 -53.339

Reading Level (dBm) -54.582 -56.704 -56.428

Over Limit (dB) -47.740 -45.313 -40.339

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-6.158 -1.609 3.089

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 81 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 10:LTE band25 1850MHz

Page No.: 60
Time: 2024/03/21 - 08:12 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 3700.000 5550.000 7400.000

Measure Level (dBm) -60.832 -57.305 -54.303

Reading Level (dBm) -54.634 -56.831 -57.174

Over Limit (dB) -47.832 -44.305 -41.303

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-6.198 -0.474 2.871

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 82 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

LTE Band26: Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 11:LTE band26 814MHz

Page No.: 83
Time: 2024/03/21 - 08:14 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 91.110 225.940 531.490

Measure Level (dBm) -79.774 -71.724 -64.475

Reading Level (dBm) -97.214 -96.214 -94.525

Over Limit (dB) -66.774 -58.724 -51.475

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
17.440 24.490 30.050

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 83 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 11:LTE band26 814MHz

Page No.: 84
Time: 2024/03/21 - 08:14 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 107.600 269.590 554.770

Measure Level (dBm) -69.547 -69.428 -68.199

Reading Level (dBm) -98.647 -94.388 -98.389

Over Limit (dB) -56.547 -56.428 -55.199

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
29.100 24.960 30.190

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 84 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 11:LTE band26 814MHz

Page No.: 61
Time: 2024/03/21 - 08:12 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 1628.000 2442.000 3256.000

Measure Level (dBm) -68.745 -64.410 -62.569

Reading Level (dBm) -55.773 -55.155 -54.123

Over Limit (dB) -55.745 -51.410 -49.569

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-12.972 -9.255 -8.446

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 85 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 11:LTE band26 814MHz

Page No.: 62
Time: 2024/03/21 - 08:12 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 1628.000 2442.000 3256.000

Measure Level (dBm) -67.490 -65.206 -61.753

Reading Level (dBm) -55.435 -55.579 -53.624

Over Limit (dB) -54.490 -52.206 -48.753

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-12.055 -9.627 -8.129

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 86 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

LTE Band41: Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 12:LTE band41 2605MHz

Page No.: 85
Time: 2024/03/21 - 08:14 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 69.770 170.650 376.290

Measure Level (dBm) -73.716 -73.393 -70.570

Reading Level (dBm) -98.086 -97.703 -97.940

Over Limit (dB) -60.716 -60.393 -57.570

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
24.370 24.310 27.370

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 87 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 12:LTE band41 2605MHz

Page No.: 86
Time: 2024/03/21 - 08:14 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 114.390 255.040 599.390

Measure Level (dBm) -67.617 -73.828 -66.124

Reading Level (dBm) -97.377 -96.678 -97.894

Over Limit (dB) -54.617 -60.828 -53.124

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
29.760 22.850 31.770

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 88 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 12:LTE band41 2605MHz

Page No.: 5
Time: 2024/03/26 - 15:57 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 5210.000 7815.000 10420.000

Measure Level (dBm) -57.214 -53.330 -48.670

Reading Level (dBm) -55.862 -57.811 -55.869

Over Limit (dB) -44.214 -40.330 -35.670

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-1.352 4.481 7.199

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 89 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 12:LTE band41 2605MHz

Page No.: 6
Time: 2024/03/26 - 15:57 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 5210.000 7815.000 10420.000

Measure Level (dBm) -57.487 -54.107 -51.500

Reading Level (dBm) -56.111 -58.718 -56.986

Over Limit (dB) -44.487 -41.107 -38.500

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-1.376 4.611 5.486

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 90 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

LTE Band26 - IC :
Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 13:LTE band26 836.5MHz

Page No.: 87
Time: 2024/03/21 - 08:14 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 75.590 218.180 462.620

Measure Level (dBm) -74.800 -71.550 -67.694

Reading Level (dBm) -96.970 -95.120 -96.194

Over Limit (dB) -61.800 -58.550 -54.694

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
22.170 23.570 28.500

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 91 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC2 Limit: FCC Part 22&24&27 Probe: 30-1G EUT: POS Note: Mode 13:LTE band26 836.5MHz

Page No.: 88
Time: 2024/03/21 - 08:14 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 121.180 279.290 738.100

Measure Level (dBm) -66.962 -72.039 -61.885

Reading Level (dBm) -97.192 -98.029 -95.185

Over Limit (dB) -53.962 -59.039 -48.885

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
30.230 25.990 33.300

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 92 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 13:LTE band26 836.5MHz

Page No.: 7
Time: 2024/03/26 - 15:57 Margin: 0 Polarity: Horizontal Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 1673.000 2509.500 3346.000

Measure Level (dBm) -67.315 -64.359 -62.900

Reading Level (dBm) -55.814 -54.563 -54.210

Over Limit (dB) -54.315 -51.359 -49.900

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-11.501 -9.796 -8.690

Type
PK PK PK

Report no.: 2390387R-RF-US-P07V01

Page 93 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098

Profile: 2390387R Engineer: Pengchengyang Site: AC5 Limit: FCC Part 22&24&27 Probe: 1-18G_AMP EUT: POS Note: Mode 13:LTE band26 836.5MHz

Page No.: 8
Time: 2024/03/26 - 15:57 Margin: 0 Polarity: Vertical Power: 120 Vac / 60 Hz

No Mark

1

2

3

*

Frequency (MHz) 1673.000 2509.500 3346.000

Measure Level (dBm) -66.190 -65.996 -61.586

Reading Level (dBm) -55.108 -56.658 -53.116

Over Limit (dB) -53.190 -52.996 -48.586

Limit (dBm)
-13.000 -13.000 -13.000

Factor (dB)
-11.082 -9.338 -8.470

Type
PK PK PK

1. The test frequency range, 9kHz~30MHz, worst case are at least 20dB below the limits, therefore no data appear in the report. 2. The test frequency range, 18GHz~tenth harmonic of the highest fundamental test result on peak is lower than average limit, all is the noise base, therefore no data appear in the report.

Report no.: 2390387R-RF-US-P07V01

Page 94 / 95

DEKRA Testing and Certification (Suzhou) Co., Ltd. No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098
5 Test setup photo and EUT Photo
Remark: The test setup photo and EUT Photo please see appendix.
The End

VERDICT: PASS

Report no.: 2390387R-RF-US-P07V01

Page 95 / 95



Related FCC IDs: