Verkada BX21 (Wireless Relay) Install Guide
Users Manual
Verkada Inc 6059001 BX21 Wireless Relay 2AWUU6059001 2AWUU6059001 6059001
Installation Guide for Verkada models including: 6059001, 2AWUU6059001, BX21 Wireless Relay, BX21, Wireless Relay, Relay
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 15 Pages, 1.85MB
Document DEVICE REPORTGetApplicationAttachment.html?id=6236206Install Guide BX21 Wireless Relay Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 [email protected] All specifications are subject to change without notice Copyright © 2022 Verkada Inc. All rights reserved. Document Document Details V1.0 (20221104) (V1.0 first published 20221104) Firmware Firmware version can be verified on Verkada Command command.verkada.com. 2 Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice [email protected] Copyright © 2022 Verkada Inc. All rights reserved. Introduction What's in the box 2x Wall Screws BX21 Wireless Relay 1x VHB Adhesive Mounting Strip 1x T10 Torx Wrench 2x Wall Anchors What you'll need BH61 Wireless Alarm Hub 12-24VDC power source: 12VDC at 2.5A max 24VDC at 1.25A max A smartphone or laptop A #2 Phillips driver (screwdriver or power drill) inch (3mm) drill bit ¼ inch (6.35mm) drill bit, if using wall anchors This product does not include a power adapter or power supply and is intended to be supplied by a certified Power Supply marked "Limited Power Source", "LPS" and rated voltage within 12-24 Vdc, 2.5-1.25A, Tmax 50 °C. 3 Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice [email protected] Copyright © 2022 Verkada Inc. All rights reserved. Introduction Relay Overview 1/2 Cover Status LED Security Screw Terminal Blocks Test/Pairing Button Status LED Behavior Flashing Orange Relay is updating firmware Flashing Blue Relay is powered, but cannot reach the hub Solid Blue Relay is running, connected to the hub and receiving / transmitting events Connect Please note: Add your BH61 Wireless Alarm Hub to Command before setting up your Wireless Relay. To add your Relay, please proceed to: verkada.com/start 4 Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice [email protected] Copyright © 2022 Verkada Inc. All rights reserved. Introduction Relay Overview 2/2 Interface/Connectors 1. Relay Output (NO, COM, NC) 12VDC operates at 2.5A Max 24VDC operates at 1.25A Max 2. (Optional) Wired Signal Input (GND, IN) 3. Relay Power Input (GND, 12-24VDC) 4. Test/Pairing Button 1. Relay Output 2. Wired Signal Input 3. Relay Power Input 4. Test/Pairing Button 5 Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice [email protected] Copyright © 2022 Verkada Inc. All rights reserved. Introduction BX21 Technical Specifications Power Consumption DC Power Input Inputs 30W Maximum 12-24VDC Wired Signal Input (Optional) Relay Outputs 1 Wet Relay Relay Output Voltage Relay Input Voltage, e.g. 12VDC Input, 12VDC Output 2.5A max 24VDC Input, 24VDC Output 1.25A max Wireless Communication Wireless Range Dimensions Weight Operating Temperature Relay Durability Compliance Connectivity Included Accessories Mounting Options Proprietary 915 MHz (US, Canada) / 868 MHz (UK, Europe) / 916.8MHz (ANZ) 1,000 ft (lineofsight); 200 ft (typical environment) 44.00mm(W) x 119.60mm (L) x 30.30mm (H) 226g / 8oz 0°C - 50°C, 0- 90% Humidity (non condensing) 100,000 Cycles at Max Load FCC, IC Connects to Verkada's Wireless Alarm Hub (BH61) 1x T10 Torx Wrench 1x VHB Adhesive Strip, 2x Wall Anchors & Screws 6 Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice [email protected] Copyright © 2022 Verkada Inc. All rights reserved. Installation Mounting 1/3 Using the provided T10 Torx Wrench, loosen the security screw at the base of the Relay. With the security screw fully loosened, lift the cover upwards to remove it entirely. 7 Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice [email protected] Copyright © 2022 Verkada Inc. All rights reserved. Installation Mounting 2/3 Wall Mounting: At the installation location, mark the mounting surface through the perforations in the top-right and bottom-left of the Relay, as shown. For a solid material like wood or metal, drill inch pilot holes in the mounting surface at the marks. For drywall, drill ¼ inch holes. Insert plastic Wall Anchors into the holes. Secure the Relay to the surface using the provided Wall Screws. VHB Mounting: Peel the protective film from one side of the adhesive mounting strip. Adhere to the back side of the Relay. Peel the remaining protective film and affix the Relay to the mounting surface. 8 Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice [email protected] Copyright © 2022 Verkada Inc. All rights reserved. Installation Mounting 3/3 Wire the Relay. See Pages 10-13 for Recommended Wiring Instructions. Once wiring has been completed, replace the device's cover. Tighten the security screw. 9 Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice [email protected] Copyright © 2022 Verkada Inc. All rights reserved. Installation Recommended Wiring (1/4) Verkada's BX21 Wireless Relay is capable of supporting output devices e.g. sirens, strobes, etc. that require 12-24V voltage and draw up to 2.5A for 12V or 1.25A for 24V (resistive). Signal Power (22 Gauge) Power (18 Gauge) AWG 22 18 Conductor Yes Yes Shielded Yes Yes Max Length 600 ft 1500 ft Wiring methods shall be in accordance with National Electrical Code, ANSI/NFPA 70. Shielded Wiring With the BX21, you must use shielded wiring. Improper shielding may result in unintended product behavior. The BX21 Wireless Relay sits in-line with DC-powered output devices which can be triggered wirelessly. The Relay can also transmit signals from a wired input. The Relay enables output devices in a wet configuration, i.e. devices which do not draw power from external sources beyond the Relay itself. According to the requirements of the output device, these should be wired to either the Normally Open (NO) or Normally Closed (NC) terminals in the terminal block denoted Relay. The power source which supplies the Relay, and implicitly the output device, should be wired to the terminal block marked Power. 10 Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice [email protected] Copyright © 2022 Verkada Inc. All rights reserved. Installation Recommended Wiring (2/4) Wiring Steps: 1. Noting polarity, wire the output device to NO (Page 12) or NC (Page 13) and COM on the Relay terminal block. 2. Optionally: wire an additional input to the Signal terminal block e.g. a door sensor. 3. Noting polarity, wire a 12-24VDC power source to GND and COM on the Power terminal block. 4. Press and hold the Test/Pairing button to trigger the Relay (the button is recessed and is easily accessed using the provided Torx Wrench). If wired correctly, the output device should exhibit its expected output behavior. Upon output device failure, please confirm the device operates within power limitations and that the Relay is wired as per instructions. The Test/Pairing button can also be pressed in the event that the Relay does not automatically pair with a BH61 Hub, however, this behaviour is not expected. Do not hesitate to contact support: verkada.com/support 11 Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice [email protected] Copyright © 2022 Verkada Inc. All rights reserved. Installation Recommended Wiring (3/4) Normally Open (NO) Relay NO COM NC Signal GND IN Normally Open (NO) Output Device e.g. Strobe + - Optional: Wired Input (Open/Short) Power GND 12-24 V - Of 12-24V DC Power Supply Of 12-24V DC + Power Supply 12 Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice [email protected] Copyright © 2022 Verkada Inc. All rights reserved. Installation Recommended Wiring (4/4) Normally Closed (NC) Relay NO COM NC Signal GND IN Normally Closed (NC) Output Device e.g. Strobe + Optional: Wired Input (Open/Short) Power GND 12-24 V - Of 12-24V DC Power Supply Of 12-24V DC + Power Supply 13 Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice [email protected] Copyright © 2022 Verkada Inc. All rights reserved. Appendix BX21 Compliance FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. IMPORTANT NOTE : FCC Radiation Exposure Statement : This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. IC Statement This device complies with ISED's licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d' ISED applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) le dispositif ne doit pas produire de brouillage préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable. IMPORTANT NOTE: IC Radiation Exposure Statement: This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. NOTE IMPORTANTE: Déclaration d'exposition aux rayonnements d'IC : Cet équipement est conforme aux limites d'exposition aux rayonnements IC RSS-102 définies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec une distance minimale de 20 cm entre le radiateur et votre corps. Note 14 This equipment is for use in a restricted access area. Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 [email protected] All specifications are subject to change without notice Copyright © 2022 Verkada Inc. All rights reserved. Appendix Support Thank you for purchasing this Verkada product. If for any reason things don't work right, or you need assistance, please contact us immediately. verkada.com/support Sincerely, The Verkada Team 15 Verkada Inc. 405 E 4th Ave, San Mateo, CA 94401 All specifications are subject to change without notice [email protected] Copyright © 2022 Verkada Inc. All rights reserved.
References
Related FCC IDs:
- 2AWUU6059001 - Verkada Inc BX21 Wireless Relay [6059001] Google PDF-XChange Viewer [Version: 2.0 (Build 40.7) (Nov 25 2008; 17:31:42)]