EMC Test Report

微软用户

test report

SHEN ZHEN GTL TECHNOLOGY CO .,LTD CW530 5 in 1 Charging Station 2A4TT-CW530 2A4TTCW530 cw530

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 27 Pages, 1.34MB

Document DEVICE REPORTGetApplicationAttachment.html?id=7389198
Page 1 of 27

Report No.: AIT24050612FW1

FCC TEST REPORT
Client Information:

Applicant: SHEN ZHEN GTL TECHNOLOGY CO .,LTD

Applicant add.:

2/F&6/F of Building B11, Hengfeng Industrial city, Hangcheng Street, Baoan District, Shenzhen, Guangdong, China.518126

Product Information:

Product Name: 5 in 1 Charging Station Model No.: CW520, CW530
Brand Name: N/A FCC ID: 2A4TT-CW530

Applicable standards: FCC CFR Title 47 Part 15 Subpart C

Prepared By:

Dongguan Yaxu (AiT) Technology Limited

Date of Receipt:

No.22, Jinqianling 3rd Street, Jitigang, Huangjiang,Dongguan,

Guangdong, China

Tel.: +86-769-8202 0499

Fax.: +86-769-8202 0495

May 06, 2024

Date of Test: May 06, 2024~May 10, 2024

Date of Issue: May 11, 2024

Test Result: Pass

This device described above has been tested by Dongguan Yaxu (AiT) Technology Limited and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report.
Note: This report shall not be reproduced except in full, without the written approval of Dongguan Yaxu (AiT) Technology Limited, this document may be altered or revised by Dongguan Yaxu (AiT) Technology Limited, personal only, and shall be noted in the revision of the document. This test report must not be used by the client to claim product endorsement.

Reviewed by:
Emiya Lin

Approved by:
Simba Huang

Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

1 Contents

Page 2 of 27

Report No.: AIT24050612FW1

COVER PAGE

Page

1 CONTENTS ..................................................................................................................................................................2

2 TEST SUMMARY ........................................................................................................................................................ 5

2.1 STATEMENT OF THE MEASUREMENT UNCERTAINTY ..................................................................................................5 2.2 MEASUREMENT UNCERTAINTY .................................................................................................................................5

3 TEST FACILITY ........................................................................................................................................................... 6

3.1 DEVIATION FROM STANDARD ................................................................................................................................... 6 3.2 ABNORMALITIES FROM STANDARD CONDITIONS ........................................................................................................ 6 3.3 TEST LOCATION ...................................................................................................................................................... 6

4 GENERAL INFORMATION ......................................................................................................................................... 7

4.1 EUT TEST MODE ....................................................................................................................................................8 4.2 DESCRIPTION OF TEST SETUP ................................................................................................................................. 8 4.3 PERIPHERAL LIST ....................................................................................................................................................9 4.4 EUT PERIPHERAL LIST ........................................................................................................................................... 9

5 EQUIPMENTS LIST FOR ALL TEST ITEMS ........................................................................................................... 10

6 CONDUCTED EMISSION TEST ............................................................................................................................... 10

6.1 CONDUCTED EMISSION MEASUREMENT ..................................................................................................... 12 6.2 POWER LINE CONDUCTED EMISSION LIMITS ................................................................................................12 6.3 TEST PROCEDURE ...........................................................................................................................................12 6.4 DEVIATION FROM TEST STANDARD ..............................................................................................................12 6.5 TEST SETUP ......................................................................................................................................................13 6.6 EUT OPERATING CONDITIONS .......................................................................................................................13 6.7 TEST RESULT ....................................................................................................................................................... 14

7 RADIATED EMISSION MEASUREMENT ................................................................................................................ 16

7.1 RADIATED EMISSION LIMITS .................................................................................................................................. 16 7.2 ANECHOIC CHAMBER TEST SETUP DIAGRAM ......................................................................................................... 17 7.3 TEST PROCEDURE ................................................................................................................................................ 17 7.4 DEVIATION FROM TEST STANDARD ..............................................................................................................17 7.5 TEST RESULT ....................................................................................................................................................... 18

8 BANDWIDTH TEST ...................................................................................................................................................22

8.1 TEST PROCEDURE ................................................................................................................................................ 22 8.2 TEST SETUP ..........................................................................................................................................................22

9 ANTENNA REQUIREMENT: .....................................................................................................................................26

10 TEST SETUP PHOTOGRAPHS OF EUT ............................................................................................................... 27

Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

Page 3 of 27

Report No.: AIT24050612FW1

11 EXTERNAL PHOTOGRAPHS OF EUT .................................................................................................................. 27

12 INTERNAL PHOTOGRAPHS OF EUT ................................................................................................................... 27

Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

Page 4 of 27

Report Version Revise Time

V1.0

/

Report Revise Record Issued Date Valid Version

May 11, 2024

Valid

Report No.: AIT24050612FW1
Notes Initial release

Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

Page 5 of 27

Report No.: AIT24050612FW1

2 Test Summary

Test Item

Section in CFR 47

Antenna requirement

15.203

AC Power Line Conducted Emission

15.207

Spurious Emission

15.209(a)(f)

20dB Bandwidth

15.215

Note 1. Test according to ANSI C63.10:2013. 2. The measurement uncertainty is not included in the test result. 3. Test results in other test report (RF Exposure Evaluation Report)

Result Pass Pass Pass Pass

2.1 Statement of the Measurement Uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 ­ 4 "Specification for radio disturbance and immunity measuring apparatus and methods ­ Part 4: Uncertainty in EMC Measurements" and is documented in the AiT quality system acc. To DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device.

2.2 Measurement Uncertainty

Test Item

Frequency Range

Measurement Uncertainty Notes

Radiated Emission

0.009MHz-30MHz

3.10dB

(1)

Radiated Emission

30MHz-1GHz

3.75dB

(1)

Radiated Emission

1GHz-18GHz

3.88dB

(1)

Radiated Emission

18GHz-40GHz

3.88dB

(1)

AC Power Line Conducted Emission

0.15MHz ~ 30MHz

1.20dB

(1)

Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%.

Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

Page 6 of 27

Report No.: AIT24050612FW1

3 Test Facility
The test facility is recognized, certified or accredited by the following organizations:
.CNAS- Registration No: L6177 Dongguan Yaxu (AiT) technology Limited is accredited to ISO/IEC 17025:2017 general Requirements for the competence of testing and calibration laboratories (CNAS-CL01 Accreditation Criteria for the competence of testing and calibration laboratories) on April 18, 2022
FCC-Registration No.: 703111 Designation Number: CN1313 Dongguan Yaxu (AiT) technology Limited has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files.
IC --Registration No.: 6819A CAB identifier: CN0122 The 3m Semi-anechoic chamber of Dongguan Yaxu (AiT) technology Limited has been registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 6819A
A2LA-Lab Cert. No.: 6317.01 Dongguan Yaxu (AiT) technology Limited has been accredited by A2LA for technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025: 2017 General Requirements for the Competence of Testing and Calibration Laboratories and any additional program requirements in the identified field of testing.
3.1 Deviation from standard
None
3.2 Abnormalities from standard conditions
None
3.3 Test Location
Dongguan Yaxu (AiT) Technology Limited Address: No.22, Jinqianling 3rd Street, Jitigang, Huangjiang,Dongguan, Guangdong, China Tel.: +86-769-8202 0499 Fax.: +86-769-8202 0495

Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

Page 7 of 27

Report No.: AIT24050612FW1

4 General Information

EUT Name: Model No: Serial Model: Test sample(s) ID: Sample(s) Status: Serial No.: Operation frequency: Modulation Technology: Antenna Type: Antenna gain: Hardware version.: Software version.:
Power supply:
Adapter:
Model different: Note:

5 in 1 Charging Station
CW520
CW530
24050612
Engineer sample
N/A For phone/earphone:113kHz-205kHz For watch: 300kHz-350kHz ASK
loop coil Antenna
0dBi
N/A
N/A Input:12V3A Phone Output:5W/7.5W/10W15W Earbuds Output:3W Watch Output:2.5W Model:SJT36E Input:100-240V~ 50/60Hz 1A MAX Output:12V3A PCB board, structure and internal of these model(s) are the same, So no additional models were tested. For a more detailed features description, please refer to the manufacturer's specifications or the User's Manual.

Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

Page 8 of 27

Report No.: AIT24050612FW1

4.1 EUT Test Mode

Equipment under test was operated during the measurement under the following conditions:

Test Mode Description Mode 1 AC Adapter + EUT + Wireless charger receiver+ Earphone+ Watch Mode 2 AC Adapter + EUT + Wireless charger receiver+ Earphone Mode 3 AC Adapter + EUT + Wireless charger receiver+Watch Mode 4 AC Adapter + EUT + Earphone +Watch Mode 5 AC Adapter + EUT + Wireless charger receiver Mode 6 AC Adapter + EUT + Earphone Mode 7 AC Adapter + EUT + Watch Mode 8 Test the EUT in idle mode.
Note: All test modes were pre-tested, but we only recorded the worst case in this report.

Record Pre-tested Pre-tested Pre-tested Pre-tested Pre-tested Pre-tested Pre-tested

4.2 Description of Test setup

EUT was tested in normal configuration (Please See following Block diagram) 1. Block diagram of EUT configuration

Load EUT

Adapter

AC 120V/60Hz

Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

4.3 Peripheral List

N Equipment Manufacturer
o.

Wireless

1

charger

SLY

receiver

Page 9 of 27

Model No.

Serial No.

15W

N/A

Report No.: AIT24050612FW1

Power cord N/A

signal cable N/A

2 Earphone

PocBuds

K6

N/A

N/A

N/A

3

Watch

Apple

S6

N/A

N/A

N/A

4.4 EUT Peripheral List

No. Equipment

Manufacturer

1

Adapter

N/A

EMC Compliance
FCC

Model No. SJT36E

Serial No. Power cord

signal cable

N/A

N/A

N/A

Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

Page 10 of 27
5 Equipments List for All Test Items

Report No.: AIT24050612FW1

No

Test Equipment

Manufacturerr

Model No

Serial No

Cal. Date Cal. Due Date

1

Spectrum Analyzer

R&S

FSV40

101470

2023.09.08

EMI Measuring 2
Receiver

R&S

ESR

101660

2023.09.08

3 Low Noise Pre Amplifier

HP

HP8447E

1937A01855 2023.09.08

4 Low Noise Pre Amplifier

MLA-0120-A02-

Tsj

2648A04738 2023.09.08

34

5

Passive Loop

ETS

6512

00165355

2022.09.04

TRILOG Super

6

SCHWARZBECK

Broadband test Antenna

VULB9160

9160-3206 2021.08.29

7 Broadband Horn Antenna SCHWARZBECK BBHA9120D

452

2021.08.29

SHF-EHF Horn Antenna

8

SCHWARZBECK

15-40GHz

BBHA9170

BBHA917036 7d

2023.09.12

9

EMI Test Receiver

R&S

ESCI

100124

2023.09.08

10

LISN

Kyoritsu

KNW-242

8-837-4

2023.09.08

11

LISN

12 Pro.Temp&Humi.chamber

RF Automatic Test 13
system

14

Signal Generator

Wideband Radio 15
communication tester RF Automatic Test
16 system

17

Pulse Limiter

R&S MENTEK
MW Agilent R&S
MW R&S

ESH3-Z5 MHP-150-1C

892785/016
MAA0811250 1

2023.09.08 2023.09.08

MW100-RFCB

21033016

2023.09.08

N5182A CMW500

MY50143009
1201.0002K5 0

2023.09.08 2023.09.08

MW100-RFCB

21033016

2023.09.08

ESH3-Z2

03578810.54 2023.09.08

2024.09.07 2024.09.07 2024.09.07 2024.09.07 2024.09.03 2024.08.28 2024.08.28 2026.09.11 2024.09.07 2024.09.07 2024.09.07 2024.09.07 2024.09.07 2024.09.07 2024.09.07 2024.09.07 2024.09.07

18

Switch

19

DC power supply

20

RE Software

21

CE Software

22

RF Software

MFJ Rhinos
ZHAOXIN EZ EZ MW

MFJ-2702
RXN-305D-2 EZ-EMC_RE EZ-EMC_CE
MTS 8310

CZ3457 2807000255
9 Ver.AIT-03A Ver.AIT-03A
2.0.0.0

2023.09.08
N/A N/A N/A N/A

2024.09.07
N/A N/A N/A N/A

Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

temporary antenna 23
connector(Note)

Page 11 of 27

NTS

R001

N/A

Report No.: AIT24050612FW1

N/A

N/A

Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

Page 12 of 27

Report No.: AIT24050612FW1

6 CONDUCTED EMISSION TEST
5.1 CONDUCTED EMISSION MEASUREMENT

Test Requirement: Test Method:

FCC Part15 C Section 15.207 ANSI C63.10:2013

Test Frequency Range: 150KHz to 30MHz

Receiver setup:

RBW=9KHz, VBW=30KHz, Sweep time=auto

5.2 POWER LINE CONDUCTED EMISSION Limits

FREQUENCY (MHz)
0.15 -0.5 0.50 -5.0 5.0 -30.0

Limit (dBuV)

Quas-peak

Average

66 - 56 *

56 - 46 *

56.00

46.00

60.00

50.00

Standard
FCC FCC FCC

Note: (1) *Decreases with the logarithm of the frequency.

5.3 TEST PROCEDURE
a. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected to the power mains through a line impedance stabilization network (LISN). All other support equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling impedance for the measuring instrument.
b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and forth in the center forming a bundle 30 to 40 cm long.
c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the cable may be terminated, if required, using the correct terminating impedance. The overall length shall not exceed 1 m.
d. LISN at least 80 cm from nearest part of EUT chassis. e. For the actual test configuration, please refer to the related Item ­EUT Test Photos.

5.4 DEVIATION FROM TEST STANDARD
No deviation

Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

5.5 TEST SETUP

Page 13 of 27

Ve rtic a l R e fe re n c e G ro u n d P la n e

40cm

EUT

Report No.: AIT24050612FW1
Te s t R e c e iv e r

L IS N

80cm

H o riz o n ta l R e fe re n c e G ro u n d P la n e

N o te : 1 .S u p p o rt u n its w e re c o n n e c te d to s e c o n d L IS N .

2 .B o th o f L IS N s (A M N ) a re 8 0 c m fro m E U T a n d a t le a s t 8 0

cm

fro m o th e r u n its a n d o th e r m e ta l p la n e s

s u p p o rt. u n its .

5.6 EUT OPERATING CONDITIONS
The EUT was configured for testing in a typical fashion (as a customer would normally use it). The EUT has been programmed to continuously transmit during test. This operating condition was tested and used to collect the included data.
We pretest AC 120V and AC 230V, the worst voltage was AC 120V and the data recording in the report.

Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

Page 14 of 27

Report No.: AIT24050612FW1

5.7 Test Result

Temperature Pressure Test Voltage 

25.5 101kPa AC 120V/60Hz

Relative Humidity Phase :

52.3% L

Remark: Factor =insertion loss of LISN + Cable loss +insertion loss of Pulse Limiter +insertion loss of Switch. Measurement Result=Reading Level +Correct Factor; Over Limit= Measurement Result- Limit;
Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

Page 15 of 27

Report No.: AIT24050612FW1

Temperature Pressure Test Voltage 

25.5 101kPa AC 120V/60Hz

Relative Humidity Phase :

52.3% N

Remark: Factor =insertion loss of LISN + Cable loss +insertion loss of Pulse Limiter +insertion loss of Switch. Measurement Result=Reading Level +Correct Factor; Over Limit= Measurement Result- Limit;
Notes: 1.An initial pre-scan was performed on the line and neutral lines with peak detector. 2.Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

Page 16 of 27 3.Mesurement Level = Reading level + Correct Factor

Report No.: AIT24050612FW1

6 RADIATED EMISSION MEASUREMENT

Test Requirement: Test Method: Test Frequency Range: Test site: Receiver setup:

FCC Part15 C Section 15.209

ANSI C63.10:2013

9kHz to 1GHz

Measurement Distance: 3m

Frequency

Detector

RBW VBW

Value

9KHz-150KHz Quasi-peak 200Hz 600Hz Quasi-peak

150KHz-30MHz Quasi-peak 9KHz 30KHz Quasi-peak

30MHz-1GHz Quasi-peak 100KHz 300KHz Quasi-peak

Above 1GHz

Peak Peak

1MHz 1MHz

3MHz 10Hz

Peak Average

6.1 Radiated Emission Limits

Limits for frequency below 30MHz

Frequency
0.009-0.490 0.490-1.705
1.705-30

Limit (uV/m)
2400/F(kHz) 24000/F(kHz)
30

Measurement Distance(m)
300 30 30

Limits for frequency Above 30MHz Frequency
30MHz-88MHz 88MHz-216MHz 216MHz-960MHz 960MHz-1GHz
Above 1GHz

Limit (dBuV/m @3m) 40.00 43.50 46.00 54.00 54.00 74.00

Remark
Quasi-peak Value Quasi-peak Value Quasi-peak Value
Remark Quasi-peak Value Quasi-peak Value Quasi-peak Value Quasi-peak Value
Average Value Peak Value

Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

Page 17 of 27
6.2 Anechoic Chamber Test Setup Diagram
ARadiated Emission Test-Up Frequency Below 30MHz

Report No.: AIT24050612FW1

BRadiated Emission Test-Up Frequency 30MHz~1GHz

The radiated emission tests were performed in the 3 meters chamber test site, using the setup accordance with the ANSI C63.10-2013. The specification used was the FCC 15.209 and FCC 15.205 limits.

6.3 Test Procedure

The EUT is placed on a turn table which is 0.8 meter above ground. The turn table can rotate 360 degrees to determine the position of the maximum emission level. The EUT is set 3 meters away from the receiving antenna which is mounted on a antenna tower. The antenna can move up and down between 1 to 4 meters to find out the maximum emission level. Broadband antenna (calibrated by dipole antenna) are used as a receiving antenna. Both horizontal and vertical polarization of the antenna are set on measurement.

6.4 DEVIATION FROM TEST STANDARD

No deviation

Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

Page 18 of 27

Report No.: AIT24050612FW1

6.5 Test Result
We pretest AC 120V and AC 230V in full load, half load and no load, the worst voltage was AC 120V in full load and the data recording in the report.
Measurement data:
Note: Limit dBuV/m @3m = Limit dBuV/m @300m+ 80 Limit dBuV/m @3m = Limit dBuV/m @30m + 40

9 kHz~30 MHz Smart Phone:

Frequency (MHz) 0.0122 0.1201 0.1201 0.7015 1.8720 9.4814 24.4934

Meter Reading (dBV) -22.08 42.63 29.28 19.28 20.89 25.96 23.35

Factor (dB/m) 72.98 40.72 40.72 28.92 22.61 13.84 13.25

Emission Level (dBV/m) 50.90 83.35 70.00 48.20 43.50 39.80 36.60

Limits (dBV/m)
125.70 105.94 105.94 70.69 69.50 69.50 69.50

Margin (dB) -74.80 -22.59 -35.94 -22.49 -26.00 -29.70 -32.90

Detector Type
Quasi-Peak Peak
Average Quasi-Peak Quasi-Peak Quasi-Peak Quasi-Peak

Earphones:

Frequency (MHz) 0.0331 0.1281 0.1281 0.8800 2.6749 11.8025 15.5510

Meter Reading (dBV) -14.16 41.05 27.49 17.36 26.34 22.95 24.05

Factor (dB/m) 60.06 40.67 40.67 27.24 19.36 13.65 13.55

Emission Level (dBV/m) 45.90 81.72 68.16 44.60 45.70 36.60 37.60

Limits (dBV/m)
117.08 105.39 105.39 68.73 69.50 69.50 69.50

Margin (dB) -71.18 -23.67 -37.23 -24.13 -23.80 -32.90 -31.90

Detector Type
Quasi-Peak Peak
Average Quasi-Peak Quasi-Peak Quasi-Peak Quasi-Peak

Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

Page 19 of 27

Report No.: AIT24050612FW1

Smart Watch:

Frequency (MHz) 0.0908 0.3277 0.3277 1.8568 5.5060 14.3397 26.5625

Meter Reading (dBV) 7.32 42.59 29.74 22.53 22.31 21.35 21.74

Factor (dB/m) 41.98 33.53 33.53 22.67 14.99 13.55 13.36

Emission Level (dBV/m) 49.30 76.12 63.27 45.20 37.30 34.90 35.10

Limits (dBV/m)
108.36 97.27 97.27 69.50 69.50 69.50 69.50

Margin (dB) -59.06 -21.15 -34.00 -24.30 -32.20 -34.60 -34.40

Detector Type
Quasi-Peak Peak
Average Quasi-Peak Quasi-Peak Quasi-Peak Quasi-Peak

Note: Remark: Factor =insertion loss of LISN + Cable loss +insertion loss of Pulse Limiter +insertion loss of Switch. Measurement Result=Reading Level +Correct Factor; Over Limit= Measurement Result- Limit;

Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

30MHz-1GHz
Temperature: Pressure: Test Voltage:

Page 20 of 27

Report No.: AIT24050612FW1

25.5 101 kPa AC 120V/60Hz

Relative Humidity: Polarization:

52.3% Horizontal

Remark: Factor = Antenna Factor + Cable Loss ­ Pre-amplifier. Measurement Result=Reading Level +Correct Factor; Over Limit= Measurement Result- Limit;
Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

Temperature: Pressure: Test Voltage:

Page 21 of 27

Report No.: AIT24050612FW1

25.5 101kPa AC 120V/60Hz

Relative Humidity: Polarization:

52.3% Vertical

Remark: Factor = Antenna Factor + Cable Loss ­ Pre-amplifier. Measurement Result=Reading Level +Correct Factor; Over Limit= Measurement Result- Limit;
Remarks: 1.The emission levels of other frequencies are very lower than the limit and not show in test report.
Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

7 BANDWIDTH TEST
7.1 Test Procedure

Page 22 of 27

Report No.: AIT24050612FW1

1. Set RBW = 3 kHz. 2. Set the video bandwidth (VBW)  3 x RBW. 3. Detector = Peak. 4. Trace mode = max hold. 5. Sweep = auto couple. 6. Allow the trace to stabilize. 7. Measure the maximum width of the emission that is constrained by the frequencies associated with the two outermost amplitude points (upper and lower frequencies) that are attenuated by 20 dB relative to the maximum level measured in the fundamental emission.

7.2 Test setup

Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

Page 23 of 27

Report No.: AIT24050612FW1

Smart Phone: Temperature Pressure

20  101kPa

Relative Humidity

44%

Frequency (KHz)
120.1

20dB bandwidth 99% bandwidth

(KHz)

(KHz)

2.605

-

Result Pass

Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

Earphones: Temperature Pressure

20  101kPa

Page 24 of 27

Report No.: AIT24050612FW1

Relative Humidity

44%

Frequency (KHz)
128.1

20dB bandwidth 99% bandwidth

(KHz)

(KHz)

2.547

-

Result Pass

Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

Smart Watch: Temperature Pressure

20  101kPa

Page 25 of 27

Report No.: AIT24050612FW1

Relative Humidity

44%

Frequency (KHz)
327.7

20dB bandwidth 99% bandwidth

(KHz)

(KHz)

2.677

-

Result Pass

Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

Page 26 of 27
8 ANTENNA REQUIREMENT:

Report No.: AIT24050612FW1

Standard requirement:

FCC Part15 C Section 15.203

An intentional radiator shall be designed to ensure that no antenna other than that furnished by the

responsible party shall be used with the device. The use of a permanently attached antenna or of an

antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical

connector is prohibited.

EUT Antenna: The antenna is Inductive loop coil Antenna, the best case gain of the antenna is 0dBi, reference to the appendix for details.

Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

Page 27 of 27
9 Test Setup Photographs of EUT
Please refer to separated files for Test Setup Photos of the EUT.
10 External Photographs of EUT
Please refer to separated files for External Photos of the EUT.
11 Internal Photographs of EUT
Please refer to separated files for Internal Photos of the EUT.

Report No.: AIT24050612FW1

** End of report **

Dongguan Yaxu (AiT) Technology Limited No.22, Jinqianling Third Street, Jitigang, Huangjiang,Dongguan, Guangdong, China.

