FCC 47 CFR PART 15 SUBPART C CERTIFICATION TEST REPORT
For Attendance Standalone MODEL NUMBER: DHI-ASA1222GL-D ADDITIONAL MODEL NUMBER: DH-ASA1222GL-D, ASA1222GL-D PROJECT NUMBER: 4790576052-8 REPORT NUMBER: 4790576052-8-1 FCC ID: SVN-1222GL-D ISSUE DATE: Oct. 20, 2022
Prepared for Zhejiang Dahua Vision Technology Co., Ltd.
Prepared by UL-CCIC COMPANY LIMITED No. 2, Chengwan Road, Suzhou Industrial Park, People's Republic of China
Tel: +86 769 22038881 Fax: +86 769 33244054 Website: www.ul.com
The results reported herein have been performed in accordance with the laboratory's terms of accreditation. This report shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products.

Rev. V0

Issue Date 10/20/2022

Revision History
Revisions Initial Issue

REPORT NO.: 4790576052-8-1 Page 2 of 28
Revised By

UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

REPORT NO.: 4790576052-8-1 Page 3 of 28

Clause 1

Summary of Test Results

Test Items

FCC Rules

Transmitter AC Conducted Emissions

Part 15.207

Test Results PASS

2

Transmitter Radiated Emissions

Part 15.209(a)

PASS

3

Transmitter 20dB Bandwidth

Part 15.215 (c)

PASS

Remark: The measurement result for the sample received is <Pass> according to < ANSI C63.10-2013, FCC CFR 47 Part 2, FCC CFR 47 Part 15> when <Accuracy Method> decision rule is applied.

UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

REPORT NO.: 4790576052-8-1 Page 4 of 28
TABLE OF CONTENTS
1. ATTESTATION OF TEST RESULTS ................................................................................. 5 2. TEST METHODOLOGY ..................................................................................................... 6 3. FACILITIES AND ACCREDITATION ................................................................................. 6 4. CALIBRATION AND UNCERTAINTY ................................................................................ 7
4.1. MEASURING INSTRUMENT CALIBRATION .............................................................. 7 4.2. MEASUREMENT UNCERTAINTY ............................................................................... 7 5. EQUIPMENT UNDER TEST ............................................................................................... 8 5.1. DESCRIPTION OF EUT .............................................................................................. 8 5.2. MAXIMUM FIELD STRENGTH.................................................................................... 9 5.3. CHANNEL LIST ........................................................................................................... 9 5.4. DESCRIPTION OF AVAILABLE ANTENNAS .............................................................. 9 5.5. TEST ENVIRONMENT ................................................................................................ 9 5.6. DESCRIPTION OF TEST SETUP...............................................................................10 5.7. MEASURING INSTRUMENT AND SOFTWARE USED..............................................12 6. ANTENNA PORT TEST RESULTS ...................................................................................13 6.1. AC Conducted Spurious Emissions ............................................................................13 6.2. RADIATED EMISSION ...............................................................................................16
6.2.1. SPURIOUS EMISSIONS BELOW 1G ..................................................................21 6.2.2. SPURIOUS EMISSIONS BELOW 30M................................................................23 6.3. 99%/20dB BANDWIDTH.............................................................................................26 7. ANTENNA REQUIREMENTS............................................................................................28
UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

REPORT NO.: 4790576052-8-1 Page 5 of 28

1. ATTESTATION OF TEST RESULTS

Applicant Information Company Name: Address:
Manufacturer Information Company Name: Address:
EUT Description Product Name: Model Name: Additional No.: Model Difference:
Sample Number: Data of Receipt Sample: Test Date:

Zhejiang Dahua Vision Technology Co., Ltd. No.1199, Bin'an road, Binjiang District, Hangzhou, P.R. China.
Zhejiang Dahua Vision Technology Co., Ltd. No.1199, Bin'an road, Binjiang District, Hangzhou, P.R. China.
Attendance Standalone DHI-ASA1222GL-D DH-ASA1222GL-D, ASA1222GL-D Their electrical circuit design, layout, components used and internal wiring are identical, only the color and model name is different. The model DHI-ASA1222GL-D was selected as the representative model for compliance test. 5370733 Sep. 24, 2022 Sep. 24, 2022 ~ Oct. 20 2022

APPLICABLE STANDARDS STANDARD CFR 47 Part 15 Subpart C

TEST RESULTS PASS

Prepared By:

Reviewed By:

Tom Tang Authorized By:

Leon Wu

Chris Zhong EMC&RF Lab Operations Manager

UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

REPORT NO.: 4790576052-8-1 Page 6 of 28
2. TEST METHODOLOGY
The tests documented in this report were performed in accordance with ANSI C63.10-2013, FCC CFR 47 Part 2, FCC CFR 47 Part 15, KDB414788 D01 Radiated Test Site v01r01.

3. FACILITIES AND ACCREDITATION

Accreditation Certificate

A2LA (Certificate No.: 4829.01) UL-CCIC COMPANY LIMITED has been assessed and proved to be in compliance with A2LA. FCC (FCC Designation No.: CN1247) UL-CCIC COMPANY LIMITED has been recognized to perform compliance testing on equipment subject to the Commission's Declaration of Conformity (DoC) and Certification rules. IC (IC Designation No.: 25056 CAB No.: CN0073) UL-CCIC COMPANY LIMITED has been recognized to perform compliance testing on equipment subject to the Commission's Declaration of Conformity (DoC) and Certification rules.

Note 1: All tests measurement facilities use to collect the measurement data are located at No. 2, Chengwan Road, Suzhou Industrial Park, Suzhou 215122, People's Republic of China

Note 2: For below 30MHz, lab had performed measurements at test anechoic chamber and comparing to measurements obtained on an open field site. These measurements below 30MHz had been correlated to measurements performed on an OFS.

Note 3: The test anechoic chamber in UL-CCIC COMPANY LIMITED had been calibrated and compared to the open field sites and the test anechoic chamber is shown to be equivalent to or worst case from the open field site.

UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

REPORT NO.: 4790576052-8-1 Page 7 of 28
4. CALIBRATION AND UNCERTAINTY
4.1. MEASURING INSTRUMENT CALIBRATION
The measuring equipment utilized to perform the tests documented in this report has been calibrated in accordance with the manufacturer's recommendations and is traceable to recognize national standards.

4.2. MEASUREMENT UNCERTAINTY

Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the apparatus:

Test Item
Conduction emission
Radiation Emission test (include Fundamental emission)
(9kHz-30MHz) Radiation Emission test (include Fundamental
emission) (30MHz-1GHz)

Uncertainty 3.1dB 3.4dB
3.4dB

Radiation Emission test (1GHz to 26GHz) (include Fundamental emission)

3.9dB (1GHz-18Gz) 4.2dB (18GHz-26.5Gz)

Note: This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.

UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

5. EQUIPMENT UNDER TEST

5.1. DESCRIPTION OF EUT

Product Name: Model No.:

Attendance Standalone DHI-ASA1222GL-D

Sample Type:

Normal production

REPORT NO.: 4790576052-8-1 Page 8 of 28

UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

5.2. MAXIMUM FIELD STRENGTH

Frequency Number of Transmit Chains Frequency

(MHz)

(NTX)

(MHz)

0.125

1

0.125

REPORT NO.: 4790576052-8-1 Page 9 of 28

Channel Number
1

Max. Field Strength (dBµV/m)
-7.77

5.3. CHANNEL LIST

Channel

Frequency (MHz)

Channel

1

0.125

2

Frequenc y
(MHz) N/A

Channel 3

Frequenc y
(MHz) N/A

Channel 4

Frequenc y
(MHz) N/A

5.4. DESCRIPTION OF AVAILABLE ANTENNAS

Ant.

Frequency (MHz)

Antenna Type

1

0.125

Coil Antenna

Antenna Gain (dBi) 0

Frequency (MHz)

Transmit and Receive Mode

Description

0.125

1TX, 1RX

Chain 1 can be used as transmitting/receiving antenna.

Remark: For the product, there is only one work mode and channel, and only data of the one

mode was test and recorded in the report.

5.5. TEST ENVIRONMENT
Environment Parameter Relative Humidity
Atmospheric Pressure: Temperature
Voltage:

Selected Values During Tests

56%

102kPa

TN

20 °C

VL

N/A

VN

AC 120V

VH

N/A

Note: VL= Lower Extreme Test Voltage VN= Nominal Voltage VH= Upper Extreme Test Voltage TN= Normal Temperature

UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

REPORT NO.: 4790576052-8-1 Page 10 of 28

5.6. DESCRIPTION OF TEST SETUP
SUPPORT EQUIPMENT

Item

Equipment

1

Laptop

2 Electric-magnetic Lock

3

Button

Brand Name ThinkPad / /

Model Name E590 / /

Description /
Supply by UL Lab Supply by UL Lab

I/O PORT

Cable No

Port

Connector Type Cable Type Cable Length(m) Remarks

1

/

/

/

/

/

ACCESSORY

Item Accessory

1 Credit Card

2

Adapter

3 Flash Disk

Brand Name /
HONOTO SanDisk

Model Name

Description

/ ADS-12AM-12 12012EPCU
32GB

Supplied by customer
INPUT:100-240V~ 50/60Hz Max. 0.3A OUTPUT: 12.0V1.0A
Supplied by UL Lab

The EUT can continue work normally when a card touched.

UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

REPORT NO.: 4790576052-8-1 Page 11 of 28
TEST SETUP
The EUT can work in a engineering mode. NFC support both ISO /IEC 14443A and ISO /IEC 14443B. All lowest and highest data rates as per the standards are supported - 106 kbps, 212 kbps, 424 kbps and 848 kbps, all the modes had been tested, but only the worst data (ISO 14443A 106 kbps) was recorded in the report. The EUT has been test with tag mode and without tag mode, but only the worst data with tag mode was recorded in the report.

SETUP DIAGRAM FOR TESTS

Button Adapter

Electricmagnetic Lock

Adapter

EUT

LAN Cable

Credit Card

Laptop Flash Disk

UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

REPORT NO.: 4790576052-8-1 Page 12 of 28

Used
 

5.7. MEASURING INSTRUMENT AND SOFTWARE USED

Conducted Emissions (Instrument)

Equipment

Manufacturer Model No.

Serial No.

Upper Last Cal.

Last Cal.

EMI Test Receiver

R&S

ESR3

126700 2020-12-05 2021-12-04

Artificial Mains Networks

R&S

ENY81

126711 2021-10-12 2022-10-09

Software

Used

Description

Manufacturer

Name

Version



Test Software for Conducted disturbance

R&S

EMC32

Ver. 9.25

Used
  


Equipment
Spectrum Analyzer EMI test receiver Receiver Antenna
(9kHz-30MHz) Receiver Antenna
(30MHz-1GHz)

Radiated Emissions (Instrument)

Manufacturer Model No.

Serial No.

Upper Last Cal.

Keysight

N9010B

155727 2021-05-09

R&S

ESR26

126703 2020-12-05

Schwarzbeck FMZB 1513 155456 2018-06-15

SunAR RF Motion

JB1

177821

Software

2019-01-19

Last Cal.
2022-04-09 2021-12-04 2021-06-03
2022-01-18

Used

Used


Description

Manufacturer

Name

Test Software for Radiated disturbance

Tonscend

Other instruments

Equipment Manufacturer Model No. Serial No.

TS+
Upper Last Cal.

Spectrum Analyzer Keysight

N9010B

155368 2021-05-09

Version
Ver. 2.5
Last Cal.
2022-05-08



Attenuator

PASTERNACK PE7087-6

1624

/

2022-05-23

Next Cal.
2022-12-03 2023-10-08
Next Cal.
2023-04-08 2022-12-03 2024-06-02 2025-01-17
Next Cal.
2023-05-07 2023-05-22

UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

6. ANTENNA PORT TEST RESULTS
6.1. AC Conducted Spurious Emissions
LIMITS

REPORT NO.: 4790576052-8-1 Page 13 of 28

FCC Reference: Test Method Used:

Part 15.207 ANSI C63.10 Section 6.2

FREQUENCY (MHz)
0.15 -0.5 0.50 -5.0 5.0 -30.0

Quasi-peak
66 - 56 * 56.00 60.00

Limit (dBuV)

Average
56 - 46 * 46.00 50.00

TEST SETUP AND PROCEDURE

The EUT is put on a table of non-conducting material that is 80cm high. The vertical conducting wall of shielding is located 40cm to the rear of the EUT. The power line of the EUT is connected to the AC mains through a Artificial Mains Network (A.M.N.). A EMI Measurement Receiver (R&S Test Receiver ESR3) is used to test the emissions from both sides of AC line. According to the requirements in Section 6.2 of ANSI C63.10-2003.Conducted emissions from the EUT measured in the frequency range between 0.15 MHz and 30MHz using CISPR Quasi-Peak and average detector mode. The bandwidth of EMI test receiver is set at 9kHz. The arrangement of the equipment is installed to meet the standards and operating in a manner, which tends to maximize its emission characteristics in a normal application.
UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

REPORT NO.: 4790576052-8-1 Page 14 of 28

TEST ENVIRONMENT

Temperature

22°C

Atmosphere Pressure 101kPa

Relative Humidity 56%

Test Voltage

AC 120V

LINE L RESULTS (WORST-CASE CONFIGURATION)

Level in dBµV

Frequency (MHz)
0.479843 0.479843 1.426088 1.426088 4.275270 4.275270 9.407978 9.407978 9.976620 9.976620 10.546755 10.546755

QuasiPeak (dBµV)
--35.04
--32.95
--31.20 36.21
--36.57
----35.57

Average (dBµV)
29.45 ---
27.24 ---
27.27 -----
29.09 ---
31.40 30.68
---

Limit (dBµV)
46.34 56.34 46.00 56.00 46.00 56.00 60.00 50.00 60.00 50.00 50.00 60.00

Margin (dB)
16.89 21.30 18.76 23.05 18.73 24.80 23.79 20.91 23.43 18.60 19.32 24.43

Meas. Time (ms)
1000.0 1000.0 1000.0 1000.0 1000.0 1000.0 1000.0 1000.0 1000.0 1000.0 1000.0 1000.0

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000

Line
L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1

Filter Corr. (dB)
OFF 9.7 OFF 9.7 OFF 9.7 OFF 9.7 OFF 9.8 OFF 9.8 OFF 9.5 OFF 9.5 OFF 9.4 OFF 9.4 OFF 9.4 OFF 9.4

Note: 1. Result = Reading +Correct Factor. 2. If QP Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 200 Hz (9 kHz--150 kHz), 9 kHz (150 kHz--30 MHz). 4. Step size: 80Hz (0.009MHz-0.15MHz), 4 kHz (0.15MHz-30MHz), Scan time: auto.

UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

REPORT NO.: 4790576052-8-1 Page 15 of 28
LINE N RESULTS (WORST-CASE CONFIGURATION)

Level in dBµV

Frequency (MHz)
0.487305 0.487305 1.424595 1.424595 4.278255 4.278255 9.413948 9.413948 9.982590 9.982590 10.557203 10.557203

QuasiPeak (dBµV)
--36.53
--38.03
--36.72 39.73
--41.00
----36.32

Average (dBµV)
26.28 ---
29.79 ---
29.96 -----
31.09 ---
35.79 29.66
---

Limit (dBµV)
46.21 56.21 46.00 56.00 46.00 56.00 60.00 50.00 60.00 50.00 50.00 60.00

Margin (dB)
19.94 19.68 16.21 17.97 16.04 19.28 20.27 18.91 19.00 14.21 20.34 23.68

Meas. Time (ms)
1000.0 1000.0 1000.0 1000.0 1000.0 1000.0 1000.0 1000.0 1000.0 1000.0 1000.0 1000.0

Bandwidth (kHz)
9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000 9.000

Line
N N N N N N N N N N N N

Filter
OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF

Corr. (dB)
9.6 9.6 9.6 9.6 9.6 9.6 9.9 9.9 10.0 10.0 9.9 9.9

Note: 1. Result = Reading +Correct Factor. 2. If QP Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 200 Hz (9 kHz--150 kHz), 9 kHz (150 kHz--30 MHz). 4. Step size: 80Hz (0.009MHz-0.15MHz), 4 kHz (0.15MHz-30MHz), Scan time: auto.

UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

REPORT NO.: 4790576052-8-1 Page 16 of 28

6.2. RADIATED EMISSION
TEST PROCEDURE

Fundamental field strength

FCC Reference: Test Method Used:

15.209(a) ANSI C63.10 Sections 6.3, 6.4 and 6.5

2. The limit is specified at a test distance of 30 meters. However, as specified by FCC Section 15.31 (f)(2) / RSS-Gen Section 6.4, measurements may be performed at a closer distance and the measured level corrected to the specified measurement distance by using the square of an inverse linear distance extrapolation factor (40dB/decade).

UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

REPORT NO.: 4790576052-8-1 Page 17 of 28

Radiation Disturbance Test Limit for FCC (Class B) (9kHz-1GHz)

Frequency (MHz)
0.009~0.490 0.490~1.705 1.705~30.0
30~88 88~216 216~960 960~1000

Field Strength (microvolts/meter)
2400/F(kHz) 24000/F(kHz)
30 100 150 200 500

Measurement Distance (meters) 300 30 30 3 3 3 3

Note: 1) At frequencies at or above 30 MHz, measurements may be performed at a distance other than what is specified provided: measurements are not made in the near field except where it can be shown that near field measurements are appropriate due to the characteristics of the device; and it can be demonstrated that the signal levels needed to be measured at the distance employed can be detected by the measurement equipment. Measurements shall not be performed at a distance greater than 30 meters unless it can be further demonstrated that measurements at a distance of 30 meters or less are impractical. When performing measurements at a distance other than that specified, the results shall be extrapolated to the specified distance using an extrapolation factor of 20 dB/decade (inverse linear-distance for field strength measurements; inverse-linear-distance-squared for power density measurements).

(2) At frequencies below 30 MHz, measurements may be performed at a distance closer than that specified in the regulations; however, an attempt should be made to avoid making measurements in the near field. Pending the development of an appropriate measurement procedure for measurements performed below 30 MHz, when performing measurements at a closer distance than specified, the results shall be extrapolated to the specified distance by either making measurements at a minimum of two distances on at least one radial to determine the proper extrapolation factor or by using the square of an inverse linear distance extrapolation factor (40 dB/decade). This paragraph (f) shall not apply to Access BPL devices operating below 30 MHz. Restricted bands of operation

Note: 1Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz. 2Above 38.6c
UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

FCC Reference: Test Method Used:
TEST SETUP
Below 30MHz

REPORT NO.: 4790576052-8-1 Page 18 of 28
Parts 15.231(b) / 15.209 ANSI C63.10 Sections 6.3 and 6.5

The setting of the spectrum analyser

RBW

200Hz (From 9kHz to 0.15MHz) / 9kHz (From 0.15MHz to 30MHz)

VBW

200Hz (From 9kHz to 0.15MHz) / 9kHz (From 0.15MHz to 30MHz)

Sweep

Auto

Detector

Peak/QP/ Average

Trace

Max hold

1. The testing follows the guidelines in ANSI C63.10-2013
2. The EUT was arranged to its worst case and then turntable (from 0 degree to 360 degrees) to find the maximum reading. A pre-amp and a high pass filter are used for the test in order to get better signal level. Both Horizontal, Face-on and Face-off polarizations of the antenna are set to make the measurement.
3. The EUT was placed on a turntable with 80cm meter above ground.
4. The EUT was set 3 meters from the interference receiving antenna, which was mounted on the top of a 1m height antenna tower.
5. The radiated emission limits are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 9-90 kHz, 110-490 kHz and above 1000 MHz. Radiated emission limits in these three bands are based on measurements employing an average detector.
6. For measurement below 1GHz, the initial step in collecting conducted emission data is a spectrum analyzer peak detector mode pre-scanning the measurement frequency range. Significant peaks are then marked and then Quasi Peak detector mode re-measured. If the emission level of the EUT measured by the peak detector is 3 dB lower than the applicable limit, the peak emission level will be reported. Otherwise, the emission measurement will be repeated using the quasi-peak detector and reported.
7. Although these tests were performed other than open area test site, adequate comparison measurements were confirmed against 30m OFS. Therefore sufficient tests were made to demonstrate that the alternative site produces results that correlate with the ones of tests made in an open field based on KDB 414788.

UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

Below 1G

REPORT NO.: 4790576052-8-1 Page 19 of 28

The setting of the spectrum analyser

RBW VBW Sweep Detector Trace

120k 300k Auto Peak/QP Max hold

1. The testing follows the guidelines in ANSI C63.10-2013.
2. The EUT was arranged to its worst case and then tune the antenna tower (from 1 m to 4 m) and turntable (from 0 degree to 360 degrees) to find the maximum reading. A pre-amp and a high pass filter are used for the test in order to get better signal level. Both horizontal and vertical polarizations of the antenna are set to make the measurement.
3. The EUT was placed on a turntable with 0.8 meter above ground.
4. The EUT was set 3 meters from the interference receiving antenna, which was mounted on the top of a variable height antenna tower.

UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

X axis, Y axis, Z axis positions:

REPORT NO.: 4790576052-8-1 Page 20 of 28

Note: For all radiated test, EUT had been tested in Y axis position according to the user manual that the product should be installed in Y axis position.

UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

RESULTS TEST ENVIRONMENT

REPORT NO.: 4790576052-8-1 Page 21 of 28

Temperature

22°C

Relative Humidity 56%

Atmosphere Pressure 101kPa

Test Voltage

AC120V

Remark: Through pre-testing all test polarizations, including Horizontal, Face-on and Face-off polarizations of the antenna, but only the data of the worst case is included in this test report.

6.2.1. SPURIOUS EMISSIONS BELOW 1G
Horizontal

No. Frequency Reading

[MHz]

[dBV]

1

71.9082

11.28

2

143.9864

6.08

3 215.9676 15.26

4

360.027

9.38

5 503.9894 16.27

6

720.03

11.04

Factor [dB/m] 15.06 20.21 19.87 22.52 26.34 29.59

Result [dBuV/m]
26.34 26.29 35.13 31.90 42.61 40.63

Limit [dBuV/m]
40.00 43.50 43.50 46.00 46.00 46.00

Margin [dB] -13.66 -17.21 -8.37 -14.10 -3.39 -5.37

Remark
peak peak peak peak peak peak

Note: 1. Result Level = Read Level + Correct Factor. 2. Test setup: RBW: 120 kHz, VBW: 300 kHz, Sweep time: auto. 3. If Peak Result complies with QP limit, QP Result is deemed to comply with QP limit.

UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

Vertical

REPORT NO.: 4790576052-8-1 Page 22 of 28

No. Frequency Reading

[MHz]

[dBV]

1

71.9082

17.62

2

119.928

10.66

3

150.389

14.69

4 215.9676 16.07

5 503.9894 17.37

6 648.0488 10.33

Factor [dB/m] 15.06 20.54 19.69 19.87 26.34 28.62

Result [dBuV/m]
32.68 31.20 34.38 35.94 43.71 38.95

Limit [dBuV/m]
40.00 43.50 43.50 43.50 46.00 46.00

Margin [dB] -7.32 -12.30 -9.12 -7.56 -2.29 -7.05

Remark
peak peak peak peak peak peak

Note: 1. Result Level = Read Level + Correct Factor. 2. Test setup: RBW: 120 kHz, VBW: 300 kHz, Sweep time: auto. 3. If Peak Result complies with QP limit, QP Result is deemed to comply with QP limit.

UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

REPORT NO.: 4790576052-8-1 Page 23 of 28
6.2.2. SPURIOUS EMISSIONS BELOW 30M
HORIZONTAL(THE WORST CASE) 9kHz~ 150kHz

No. Frequency Reading

[MHz]

[dBV]

1

0.0157

27.82

2

0.0181

25.78

3

0.0409

41.90

4

0.0818

38.05

5

0.1012

24.87

6

0.1248

54.13

7

0.1445

16.37

Factor [dB/m] -61.93 -61.91 -61.79 -61.89 -61.89
-61.90
-61.90

Result [dBuV/m]
-34.11 -36.13 -19.89 -23.84 -37.02
-7.77
-45.53

Limit [dBuV/m]
43.68 42.44 35.37 29.35 27.49
25.68
24.41

Margin [dB] -77.79 -78.57 -55.26 -53.19 -64.51
-33.45
-69.94

Remark
peak peak peak peak peak peak peak

Note: 1. Result = Reading Level + Correct Factor. 2. If Peak Result complies with AV and QP limit, AV and QP Result are deemed to comply with AV limit. 3. All 3 polarizations(Horizontal, Face-on and Face-off) of the loop antenna had been tested, but only the worst data recorded in the report. 4. The frequency 0.1248MHz is the fundamental carrier frequency.

UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

150kHz ~ 490kHz

REPORT NO.: 4790576052-8-1 Page 24 of 28

No. Frequency Reading

[MHz]

[dBV]

1

0.1626

31.57

2

0.2073

27.74

3

0.2483

26.96

4

0.2883

24.30

5

0.3733

21.59

6

0.4138

23.88

Factor [dB/m] -61.91 -61.92 -61.94 -61.96 -61.97 -61.97

Result [dBuV/m]
-30.34 -34.18 -34.98 -37.66 -40.38 -38.09

Limit [dBuV/m]
23.38 21.27 19.70 18.41 16.16 15.14

Margin [dB] -53.72 -55.45 -54.68 -56.07 -56.54 -53.23

Remark
peak peak peak peak peak peak

Note: 1. Result = Reading Level + Correct Factor. 2. If Peak Result complies with AV and QP limit, AV and QP Result are deemed to comply with AV limit. 3. All 3 polarizations(Horizontal, Face-on and Face-off) of the loop antenna had been tested, but only the worst data recorded in the report.

UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

490kHz ~ 30MHz

REPORT NO.: 4790576052-8-1 Page 25 of 28

No. Frequency Reading

[MHz]

[dBV]

1

0.5461

17.57

2

0.8737

14.29

3

2.6385

12.62

4

3.2672

21.21

5

3.881

17.32

6

6.5579

9.43

Factor [dB/m] -21.95 -21.93 -21.85 -21.83 -21.82 -21.76

Result [dBuV/m]
-4.38 -7.64 -9.23 -0.62 -4.50 -12.33

Limit [dBuV/m]
32.86 28.78 29.54 29.54 29.54 29.54

Margin [dB] -37.24 -36.42 -38.77 -30.16 -34.04 -41.87

Remark
peak peak peak peak peak peak

Note: 1. Result = Reading Level + Correct Factor. 2. If Peak Result complies with AV and QP limit, AV and QP Result are deemed to comply with AV limit. 3. All 3 polarizations(Horizontal, Face-on and Face-off) of the loop antenna had been tested, but only the worst data recorded in the report.

UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

6.3. 99%/20dB BANDWIDTH
LIMITS

REPORT NO.: 4790576052-8-1 Page 26 of 28

Section Part 15.215 (c) RSS-GEN Clause 6.7

FCC Part15 (15.247) Subpart C Test Item

Limit

20 Bandwidth
99% Bandwidth (Just For refer only)

For reporting purposes only. For reporting purposes only.

TEST PROCEDURE

Connect the UUT to the spectrum analyser and use the following settings:

Center Frequency Detector RBW VBW Trace Sweep

The center frequency of the channel under test Peak 1% to 5% of the occupied bandwidth approximately 3×RBW Max hold Auto couple

Allow the trace to stabilize and measure the maximum width of the emission that is constrained by the frequencies associated with the two outermost amplitude points (upper and lower frequencies) that are attenuated by 99% relative to the maximum level measured in the fundamental emission.

TEST SETUP

EUT

Attenuator

UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

TEST ENVIRONMENT

Temperature

23°C

Atmosphere Pressure 102kPa

RESULTS

REPORT NO.: 4790576052-8-1 Page 27 of 28

Relative Humidity 56%

Test Voltage

AC120V

Frequency (MHz)
0.125

99% bandwidth (kHz)
2.300

20dB bandwidth (kHz)
3.082

Remark: Because the measured signal is CW or CW-like adjusting the RBW per C63.10 would not be practical since measured bandwidth will always follow the RBW and the result will be approximately twice the RBW. And the signal was narrowband, therefore it was impossible to set RBW within 1% ­ 5%.
UL-CCIC COMPANY LIMITED This report shall not be reproduced except in full, without the written approval of UL-CCIC COMPANY LIMITED.

REPORT NO.: 4790576052-8-1 Page 28 of 28
7. ANTENNA REQUIREMENTS
PPLICABLE REQUIREMENTS
Please refer to FCC §15.203 If directional gain of transmitting antennas is greater than 6dBi, the power shall be reduced by the same level in dB comparing to gain minus 6dBi. For the fixed point-to-point operation, the power shall be reduced by one dB for every 3 dB that the directional gain of the antenna exceeds 6 dBi. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the FCC rule.
ANTENNA GAIN
The antenna gain of EUT is less than 6 dBi.
END OF REPORT