Measurement Report

Kent

Test report BLE

Shanghai Yibo Technology Co., LTD RPT2024 2BGEC-RPT2024 2BGECRPT2024 rpt2024

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 57 Pages, 4.95MB

Document DEVICE REPORTGetApplicationAttachment.html?id=7387641
CTC Laboratories, Inc.

$CNAS$

Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel: +86-755-27521059 Fax: +86-755-27521011 Http://www.sz-ctc.org.cn

TEST REPORT

Report No. ....................................: CTC2024098406

FCC ID...........................................: 2BGEC-RPT2024

Applicant ...................................... : Address.......................................... : Manufacturer..................................: Address..........................................: Product Name .............................. :

Shanghai Yibo Technology Co., LTD Room C1047, Building 9, No. 785 Tieli Road, Baoshan District, Shanghai, China
Shanghai Yibo Technology Co., LTD
Room C1047, Building 9, No. 785 Tieli Road, Baoshan District, Shanghai, China
Broadcast Module

Trade Mark .................................... : EabloPilot

Model/Type reference.................... : EabloPilot Tag

Listed Model(s) .............................. : /

Standard ....................................... : FCC CFR Title 47 Part 15 Subpart C Section 15.247

Date of receipt of test sample........: May 07, 2024

Date of testing..............................: May 07, 2024 ~ May 21, 2024

Date of issue................................: May 28, 2024

Result............................................: PASS

Compiled by: (Printed name+signature)

Lucy Lan

Supervised by: (Printed name+signature)
Approved by: (Printed name+signature)

Eric Zhang Totti Zhao

$$ $Totti$

Testing Laboratory Name ...........: CTC Laboratories, Inc.

Address.......................................... :

Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China

This test report may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product endorsement by CTC. The Test Result in the report only apply to the tested sample. The test report shall be invalid without all the signatures of testing engineers, reviewer and approver. Any objections must be raised to CTC within 15 days since the date when the report is received. It will not be taken into consideration beyond this limit. The test report merely corresponds to the test sample.

Page 2 of 57

Report No.: CTC2024098406

Table of Contents

Page

1. TEST SUMMARY .......................................................................................................................................................3
1.1. TEST STANDARDS ..................................................................................................................................................3 1.2. REPORT VERSION ..................................................................................................................................................3 1.3. TEST DESCRIPTION.................................................................................................................................................3 1.4. TEST FACILITY ....................................................................................................................................................... 4 1.5. MEASUREMENT UNCERTAINTY..................................................................................................................................5 1.6. ENVIRONMENTAL CONDITIONS .................................................................................................................................5
2. GENERAL INFORMATION ..........................................................................................................................................6
2.1. CLIENT INFORMATION.............................................................................................................................................6 2.2. GENERAL DESCRIPTION OF EUT ................................................................................................................................6 2.3. ACCESSORY EQUIPMENT INFORMATION.......................................................................................................................7 2.4. OPERATION STATE .................................................................................................................................................8 2.5. MEASUREMENT INSTRUMENTS LIST ...........................................................................................................................9
3. TEST ITEM AND RESULTS ........................................................................................................................................ 10
3.1. CONDUCTED EMISSION......................................................................................................................................... 10 3.2. RADIATED EMISSION ............................................................................................................................................ 13 3.3. BAND EDGE EMISSIONS (RADIATED) ........................................................................................................................ 24 3.4. BAND EDGE AND SPURIOUS EMISSIONS (CONDUCTED) ................................................................................................. 33 3.5. DTS BANDWIDTH................................................................................................................................................ 43 3.6. OUTPUT POWER ................................................................................................................................................. 49 3.7. POWER SPECTRAL DENSITY .................................................................................................................................... 50 3.8. DUTY CYCLE ....................................................................................................................................................... 54 3.9. ANTENNA REQUIREMENT ...................................................................................................................................... 57

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 3 of 57

Report No.: CTC2024098406

1. TEST SUMMARY
1.1. Test Standards
The tests were performed according to following standards: FCC Rules Part 15.247: Operation within the bands 902­928MHz, 2400­2483.5MHz, and 5725­5850MHz. ANSI C63.10-2013: American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.

1.2. Report Version

Revised No. 01

Report No. CTC2024098406

Date of issue May 28, 2024

Description Original

1.3. Test Description

FCC Part 15 Subpart C (15.247)

Test Item

Standard Section

Result

Test Engineer

Antenna Requirement

15.203

Pass

Alicia

Conducted Emission
Conducted Band Edge and Spurious Emissions
Radiated Band Edge and Spurious Emissions
6dB Bandwidth

15.207
15.247(d) 15.205&15.209&
15.247(d) 15.247(a)(2)

Pass Pass Pass Pass

Alicia Alicia Alicia Alicia

Conducted Max Output Power

15.247(b)(3)

Pass

Alicia

Power Spectral Density

15.247(e)

Pass

Alicia

Transmitter Radiated Spurious

15.209&15.247(d)

Pass

Alicia

Note: 1. The measurement uncertainty is not included in the test result. 2. N/A: means this test item is not applicable for this device according to the technology characteristic of device.

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 4 of 57

Report No.: CTC2024098406

1.4. Test Facility
Address of the report laboratory
CTC Laboratories, Inc. Add: Room 101 Building B,Room 107, 108, 207, 208, 303 Building A , No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, Chinaformerly 2/F., Building 1 and 1-2/F., Building 2, Jiaquan Building, High-Tech Park, Guanlan Sub-District, Longhua New District, Shenzhen, Guangdong, China)

Laboratory accreditation The test facility is recognized, certified, or accredited by the following organizations:
A2LA-Lab Cert. No.: 4340.01 CTC Laboratories, Inc. EMC Laboratory has been accredited by A2LA for technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025:2017 General Requirements for the Competence of Testing and Calibration Laboratories and any additional program requirements in the identified field of testing.
Industry Canada (Registration No.: 9783A, CAB Identifier: CN0029) CTC Laboratories, Inc. EMC Laboratory has been registered by Certification and Engineer Bureau of Industry Canada for the performance of with Registration NO.: 9783A on Jan, 2016.
FCC (Registration No.: 951311, Designation Number CN1208) CTC Laboratories, Inc. EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Registration 951311, Aug 26, 2017.

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 5 of 57

Report No.: CTC2024098406

1.5. Measurement Uncertainty

The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report acc. to TR-100028-01 "Electromagnetic compatibility and Radio spectrum Matters (ERM);Uncertainties in the measurement of mobile radio equipment characteristics; Part 1" and TR-100028-02 "Electromagnetic compatibility and Radio spectrum Matters (ERM); Uncertainties in the measurement of mobile radio equipment characteristics; Part 2" and is documented in the CTC Laboratories, Inc. quality system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device.
Below is the best measurement capability for CTC Laboratories, Inc.

Test Items

Measurement Uncertainty Notes

DTS Bandwidth

±0.0196%

(1)

Maximum Conducted Output Power

±0.686 dB

(1)

Maximum Power Spectral Density Level

±0.743 dB

(1)

Band-edge Compliance Unwanted Emissions In Non-restricted Freq Bands Conducted Emissions 9kHz~30MHz

±1.328 dB

(1)

9kHz-1GHz: ±0.746dB 1GHz-26GHz: ±1.328dB

(1)

±3.08 dB

(1)

Radiated Emissions 30~1000MHz

±4.51 dB

(1)

Radiated Emissions 1~18GHz

±5.84 dB

(1)

Radiated Emissions 18~40GHz

±6.12 dB

(1)

Note (1): This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.

1.6. Environmental Conditions

During the measurement the environmental conditions were within the listed ranges:

Temperature: Relative Humidity: Air Pressure:

15 °C to 35 °C 20 % to 75 % 101 kPa

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 6 of 57

Report No.: CTC2024098406

2. GENERAL INFORMATION
2.1. Client Information

Applicant: Address:
Manufacturer: Address:

Shanghai Yibo Technology Co., LTD
Room C1047, Building 9, No. 785 Tieli Road, Baoshan District, Shanghai, China
Shanghai Yibo Technology Co., LTD
Room C1047, Building 9, No. 785 Tieli Road, Baoshan District, Shanghai, China

2.2. General Description of EUT

Product Name: Trade Mark: Model/Type reference: Listed Model(s): Model Difference: Power Supply: Hardware Version: Software Version: Bluetooth 5.0 / BLE Modulation: Operation Frequency: Channel Number: Channel Separation: Data Rate: Antenna Type: Antenna Gain:

Broadcast Module EabloPilot EabloPilot Tag / / DC 5V/0.5A from AC/DC Adapter / /
GFSK 2402MHz~2480MHz 40 2MHz 1Mbps, 2Mbps Ceramic Chip Antenna 5.05dBi

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 7 of 57

2.3. Accessory Equipment Information

Equipment Information

Name

Model

Adapter

PS06CA050K1000CU

Cable Information

Name

Shielded Type

USB Cable

Unshielded

Test Software Information

Name

Version

EspRFTestTool

V3.6

S/N /
Ferrite Core NO
/ /

Report No.: CTC2024098406
Manufacturer / Length 150cm / /

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 8 of 57

Report No.: CTC2024098406

2.4. Operation State

Operation Frequency List: The EUT has been tested under typical operating condition. The Applicant provides communication tools software to control the EUT for staying in continuous transmitting and receiving mode for testing. BT BLE, 40 channels are provided to the EUT. Channels 00/19/39 were selected for testing. Operation Frequency List:

Channel

Frequency (MHz)

00

2402

01

2404

...

...

18

2438

19

2440

20

2442

...

...

38 39 Note: The display in grey were the channel selected for testing.

2478 2480

Test Mode:
For RF test items: The engineering test program was provided and enabled to make EUT continuous transmit. For AC power line conducted emissions: The EUT was set to connect with the Bluetooth instrument under large package sizes transmission. For Radiated spurious emissions test item: The engineering test program was provided and enabled to make EUT continuous transmit. The EUT in each of three orthogonal axis emissions had been tested, but only the worst case (X axis) data recorded in the report.

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 9 of 57

Report No.: CTC2024098406

2.5. Measurement Instruments List

Item

Test Equipment

1

MXA Signal Analyzer

2

RF Control Unit

3

Test Software

RF Test System - SRD

Manufacturer Model No.

Keysight

N9020A

Tonscend

JS0806-2

Tonscend

JS1120-3

Serial No. MY52091402
/ V2.6.88.0346

Calibrated Until Aug. 22, 2024 Aug. 22, 2024
/

Radiated emission

Item Test Equipment

Manufacturer

Model No.

1

Trilog-Broadband Antenna

2

Horn Antenna

Schwarzbeck Schwarzbeck

VULB 9163 BBHA 9120D

3

Test Receiver

Keysight

N9038A

4 Broadband Amplifier SCHWARZBECK

BBV9743B

5

Mirowave Broadband Amplifier

SCHWARZBECK

BBV9718C

6

3m chamber 3

YIHENG

EE106

7

Test Software

FARA

EZ-EMC

Serial No.
01026 9120D-647 MY56400071
259 111
/ FA-03A2

Calibrated Until
Dec. 18, 2024 Sep. 25, 2025 Dec. 12, 2024 Dec. 12, 2024 Dec. 12, 2024 Aug. 28, 2026
/

Item Test Equipment

1

LISN

2

LISN

3 EMI Test Receiver

4

ISN CAT6

5

ISN CAT5

6

Test Software

Conducted emission

Manufacturer

Model No.

R&S

ENV216

R&S

ENV216

R&S

ESCS30

Schwarzbeck

NTFM 8158

Schwarzbeck

NTFM 8158

R&S

EMC32

Serial No. 101112 101113 100353
CAT6-8158-0046 CAT5-8158-0046
6.10.10

Calibrated until Dec. 12, 2024 Dec. 12, 2024 Dec. 12, 2024 Dec. 12, 2024 Dec. 12, 2024
/

Note: 1. The Cal. Interval was one year. 2. The Cal. Interval was three years of the antenna. 3. The cable loss has been calculated in test result which connection between each test instruments.

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 10 of 57

Report No.: CTC2024098406

3. TEST ITEM AND RESULTS
3.1. Conducted Emission
Limit FCC CFR Title 47 Part 15 Subpart C Section 15.207

Frequency (MHz)
0.15 - 0.5 0.5 - 5 5 - 30
* Decreases with the logarithm of the frequency.

Conducted Limit (dBV)

Quasi-peak

Average

66 to 56 *

56 to 46 *

56

46

60

50

Test Configuration

Test Procedure
1. The EUT was setup according to ANSI C63.10:2013 requirements. 2. The EUT was placed on a platform of nominal size, 1 m by 1.5 m, raised 80 cm above the conducting ground plane. The vertical conducting plane was located 40 cm to the rear of the EUT. All other surfaces of EUT were at least 80 cm from any other grounded conducting surface. 3. The EUT and simulators are connected to the main power through a line impedance stabilization network (LISN). The LISN provides a 50 ohm / 50 H coupling impedance for the measuring equipment. 4. The peripheral devices are also connected to the main power through a LISN. (Please refer to the block diagram of the test setup and photographs) 5. Each current-carrying conductor of the EUT power cord, except the ground (safety) conductor, was individually connected through a LISN to the input power source. 6. The excess length of the power cord between the EUT and the LISN receptacle were folded back and forth at the center of the lead to form a bundle not exceeding 40 cm in length. 7. Conducted emissions were investigated over the frequency range from 0.15MHz to 30MHz using a receiver bandwidth of 9 kHz. 8. During the above scans, the emissions were maximized by cable manipulation.
Test Mode
Please refer to the clause 2.4.
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Test Result
Test Voltage: Terminal: Remark:

Page 11 of 57
AC 120V/60Hz Line Only worse case is reported

Report No.: CTC2024098406

Emission Level = Read Level + Correct Factor
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Test Voltage: Terminal: Remark:

Page 12 of 57
AC 120V/60Hz Neutral Only worse case is reported

Report No.: CTC2024098406

Emission Level = Read Level + Correct Factor
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 13 of 57

Report No.: CTC2024098406

3.2. Radiated Emission
Limit FCC CFR Title 47 Part 15 Subpart C Section 15.209

Frequency (MHz)
0.009~0.490 0.490~1.705 1.705~30.0
30~88 88~216 216~960 960~1000

Field Strength (microvolts/meter)
2400/F (kHz) 24000/F (kHz)
30 100 150 200 500

Measurement Distance (meters) 300 30 30 3 3 3 3

Frequency Range (MHz) Above 1000

Peak 74

dBV/m (at 3 meters) Average 54

Note: (1) The tighter limit applies at the band edges. (2) Emission Level (dBV/m)=20log Emission Level (V/m).

Test Configuration

Below 30MHz Test Setup
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 14 of 57

Report No.: CTC2024098406

30-1000MHz Test Setup

Test Procedure

Above 1GHz Test Setup

1. The EUT was setup and tested according to ANSI C63.10:2013. 2. The EUT is placed on a turn table which is 0.8 meter above ground for below 1 GHz, and 1.5 m for above 1 GHz. The turn table is rotated 360 degrees to determine the position of the maximum emission level. 3. The EUT was set 3 meters from the receiving antenna, which was mounted on the top of a variable height antenna tower. 4. For each suspected emission, the EUT was arranged to its worst case and then tune the Antenna tower (from 1 m to 4 m) and turntable (from 0 degree to 360 degrees) to find the maximum reading. A pre-amp and a high pass filter are used for the test in order to get better signal level to comply with the guidelines. 5. Set to the maximum power setting and enable the EUT transmit continuously. 6. Use the following spectrum analyzer settings (1) Span shall wide enough to fully capture the emission being measured; (2) 9k ­ 150kHz: RBW=300 Hz, VBW=1 kHz, Sweep=auto, Detector function=peak, Trace=max hold (3) 0.15M ­ 30MHz: RBW=10 kHz, VBW=30 kHz, Sweep=auto, Detector function=peak, Trace=max hold (4) 30M - 1 GHz: RBW=120 kHz, VBW=300 kHz, Sweep=auto, Detector function=peak, Trace=max hold If the emission level of the EUT measured by the peak detector is 3 dB lower than the applicable limit, the

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 15 of 57

Report No.: CTC2024098406

peak emission level will be reported. Otherwise, the emission measurement will be repeated using the quasi-peak detector and reported. (5) From 1 GHz to 10th harmonic: RBW=1MHz, VBW=3MHz Peak detector for Peak value. RBW=1MHz, VBW see note 1 with Peak Detector for Average Value. Note 1: For measurements above 1 GHz the resolution bandwidth is set to 1 MHz, then the video bandwidth is set to 3 MHz for peak measurements and 1 MHz resolution bandwidth with 1/T video bandwidth with peak detector for average measurements. For the Duty Cycle please refer to clause 3.8 Duty Cycle.

Test Mode Please refer to the clause 2.4.

Test Result
9 kHz~30 MHz From 9 kHz to 30 MHz: The conclusion is PASS.
Note: The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible value has no need to be reported.

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

30MHz-1GHz Ant. Pol. Test Mode: Remark:

Page 16 of 57
Horizontal TX BLE 1M Mode 2402MHz Only worse case is reported.

Report No.: CTC2024098406

Remarks: 1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor 2.Margin value = Level -Limit value
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Ant. Pol. Test Mode: Remark:

Page 17 of 57
Vertical TX BLE 1M Mode 2402MHz Only worse case is reported.

Report No.: CTC2024098406

Remarks: 1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor 2.Margin value = Level -Limit value
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Above 1GHz Ant. Pol. Test Mode: Remark:

Page 18 of 57

Report No.: CTC2024098406

Horizontal
TX BLE 1M Mode 2402MHz No report for the emission which more than 20 dB below the prescribed limit.

Remarks: 1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor 2.Margin value = Level -Limit value

Ant. Pol. Test Mode: Remark:

Vertical
TX BLE 1M Mode 2402MHz No report for the emission which more than 20 dB below the prescribed limit.

Remarks: 1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor 2.Margin value = Level -Limit value
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Ant. Pol. Test Mode: Remark:

Page 19 of 57

Report No.: CTC2024098406

Horizontal
TX BLE 1M Mode 2440MHz No report for the emission which more than 20 dB below the prescribed limit.

Remarks: 1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor 2.Margin value = Level -Limit value

Ant. Pol. Test Mode: Remark:

Vertical
TX BLE 1M Mode 2440MHz No report for the emission which more than 20 dB below the prescribed limit.

Remarks: 1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor 2.Margin value = Level -Limit value

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Ant. Pol. Test Mode: Remark:

Page 20 of 57

Report No.: CTC2024098406

Horizontal
TX BLE 1M Mode 2480MHz No report for the emission which more than 20 dB below the prescribed limit.

Remarks: 1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor 2.Margin value = Level -Limit value

Ant. Pol. Test Mode: Remark:

Vertical
TX BLE 1M Mode 2480MHz No report for the emission which more than 20 dB below the prescribed limit.

Remarks: 1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor 2.Margin value = Level -Limit value

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Ant. Pol. Test Mode: Remark:

Page 21 of 57

Report No.: CTC2024098406

Horizontal
TX BLE 2M Mode 2402MHz No report for the emission which more than 20 dB below the prescribed limit.

Remarks: 1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor 2.Margin value = Level -Limit value

Ant. Pol. Test Mode: Remark:

Vertical
TX BLE 2M Mode 2402MHz No report for the emission which more than 20 dB below the prescribed limit.

Remarks: 1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor 2.Margin value = Level -Limit value
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Ant. Pol. Test Mode: Remark:

Page 22 of 57

Report No.: CTC2024098406

Horizontal
TX BLE 2M Mode 2440MHz No report for the emission which more than 20 dB below the prescribed limit.

Remarks: 1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor 2.Margin value = Level -Limit value

Ant. Pol. Test Mode: Remark:

Vertical
TX BLE 2M Mode 2440MHz No report for the emission which more than 20 dB below the prescribed limit.

Remarks: 1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor 2.Margin value = Level -Limit value

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Ant. Pol. Test Mode: Remark:

Page 23 of 57

Report No.: CTC2024098406

Horizontal
TX BLE 2M Mode 2480MHz No report for the emission which more than 20 dB below the prescribed limit.

Remarks: 1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor 2.Margin value = Level -Limit value

Ant. Pol. Test Mode: Remark:

Vertical
TX BLE 2M Mode 2480MHz No report for the emission which more than 20 dB below the prescribed limit.

Remarks: 1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor 2.Margin value = Level -Limit value

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 24 of 57

Report No.: CTC2024098406

3.3. Band Edge Emissions (Radiated)

Limit FCC CFR Title 47 Part 15 Subpart C Section 15.247 (d)

Restricted Frequency Band (MHz)
2310 ~ 2390 2483.5 ~ 2500

Peak 74 74

(dBV/m) (at 3m)

Average 54 54

Test Configuration

Test Procedure
1. The EUT was setup and tested according to ANSI C63.10:2013 requirements. 2. The EUT is placed on a turn table which is 1.5 meter above ground. The turn table is rotated 360 degrees to determine the position of the maximum emission level. 3. The EUT was positioned such that the distance from antenna to the EUT was 3 meters. 4. The antenna is scanned from 1 meter to 4 meters to find out the maximum emission level. This is repeated for both horizontal and vertical polarization of the antenna. In order to find the maximum emission, all of the interface cables were manipulated according to ANSI C63.10:2013 on radiated measurement. 5. The receiver set as follow: RBW=1MHz, VBW=3MHz Peak detector for Peak value. RBW=1MHz, VBW see note 1 with Peak Detector for Average Value.
Note 1: For measurements above 1 GHz the resolution bandwidth is set to 1 MHz, then the video bandwidth is set to 3 MHz for peak measurements and 1 MHz resolution bandwidth with 1/T video bandwidth with peak detector for average measurements. For the Duty Cycle please refer to clause 3.8 Duty Cycle.
Test Mode
Please refer to the clause 2.4.
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Test Result
Ant. Pol. Test Mode:

Page 25 of 57
Horizontal TX BLE 1M Mode 2402MHz

Report No.: CTC2024098406

Remarks: 1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor 2.Margin value = Level -Limit value
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Ant. Pol. Test Mode:

Page 26 of 57
Vertical TX BLE 1M Mode 2402MHz

Report No.: CTC2024098406

Remarks: 1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor 2.Margin value = Level -Limit value
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Ant. Pol. Test Mode:

Page 27 of 57
Horizontal TX BLE 1M Mode 2480MHz

Report No.: CTC2024098406

Remarks: 1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor 2.Margin value = Level -Limit value
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Ant. Pol. Test Mode:

Page 28 of 57
Vertical TX BLE 1M Mode 2480MHz

Report No.: CTC2024098406

Remarks: 1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor 2.Margin value = Level -Limit value
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Ant. Pol. Test Mode:

Page 29 of 57
Horizontal TX BLE 2M Mode 2402MHz

Report No.: CTC2024098406

Remarks: 1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor 2.Margin value = Level -Limit value
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Ant. Pol. Test Mode:

Page 30 of 57
Vertical TX BLE 2M Mode 2402MHz

Report No.: CTC2024098406

Remarks: 1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor 2.Margin value = Level -Limit value
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Ant. Pol. Test Mode:

Page 31 of 57
Horizontal TX BLE 2M Mode 2480MHz

Report No.: CTC2024098406

Remarks: 1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor 2.Margin value = Level -Limit value
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Ant. Pol. Test Mode:

Page 32 of 57
Vertical TX BLE 2M Mode 2480MHz

Report No.: CTC2024098406

Remarks: 1.Factor (dB/m) = Antenna Factor (dB/m)+Cable Factor (dB)-Pre-amplifier Factor 2.Margin value = Level -Limit value
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 33 of 57

Report No.: CTC2024098406

3.4. Band Edge and Spurious Emissions (Conducted)
Limit
FCC CFR Title 47 Part 15 Subpart C Section 15.247 (d) In any 100 kHz bandwidth outside the frequency band in which the spread spectrum intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If the transmitter complies with the conducted power limits based on the use of RMS averaging over a time interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of 20 dB.
Test Configuration

Test Procedure
1. The transmitter output was connected to the spectrum analyzer through an attenuator, the path loss was compensated to the results for each measurement.
2. Set to the maximum power setting and enable the EUT transmit continuously. 3. Use the following spectrum analyzer settings:
RBW = 100 kHz, VBW  RBW, scan up through 10th harmonic. Sweep = auto, Detector function = peak, Trace = max hold. 4. Measure and record the results in the test report.
Test Mode
Please refer to the clause 2.4.

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 34 of 57

Test Result

Band Edge Conducted Test

TestMode BLE_1M BLE_2M

Antenna Ant1 Ant1

ChName
Low High Low High

Freq(MHz)
2402 2480 2402 2480

RefLevel[dBm]
9.79 6.94 7.93 5.74

Conducted Spurious Emissions Test

TestMode BLE_1M
BLE_2M

Antenna Ant1
Ant1

Freq(MHz) 2402 2440 2480 2402 2440 2480

FreqRange [MHz]
Reference 30~1000 1000~26500 Reference 30~1000 1000~26500 Reference 30~1000 1000~26500 Reference 30~1000 1000~26500 Reference 30~1000 1000~26500 Reference 30~1000 1000~26500

RefLevel [dBm] 10.81 10.81 10.81 7.89 7.89 7.89 7.99 7.99 7.99 8.62 8.62 8.62 8.44 8.44 8.44 8.63 8.63 8.63

Report No.: CTC2024098406

Result[dBm]
-32.53 -52.45 -37.03 -51.32

Limit[dBm]
-20.21 -23.06 -22.07 -24.26

Verdict
PASS PASS PASS PASS

Result[dBm]
10.81 -68.38 -30.36 7.89 -68.43 -36.63 7.99 -68.5 -35.71 8.62 -68.45 -35.53 8.44 -68.43 -36.65 8.63 -68.4 -33.69

Limit[dBm]
---19.19 -19.19
---22.11 -22.11
---22.01 -22.01
---21.38 -21.38
---21.56 -21.56
---21.37 -21.37

Verdict
PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS PASS

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 35 of 57
Band Edge Conducted Test plot as follows:
BLE_1M_Ant1_Low_2402

Report No.: CTC2024098406

BLE_1M_Ant1_High_2480

BLE_2M_Ant1_Low_2402

BLE_2M_Ant1_High_2480
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 36 of 57

Report No.: CTC2024098406

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 37 of 57
Conducted Spurious Emissions Test plot as follows:
BLE_1M_Ant1_2402_0~Reference

Report No.: CTC2024098406

BLE_1M_Ant1_2402_30~1000

BLE_1M_Ant1_2402_1000~26500

BLE_1M_Ant1_2440_0~Reference
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 38 of 57

Report No.: CTC2024098406

BLE_1M_Ant1_2440_30~1000
BLE_1M_Ant1_2440_1000~26500
BLE_1M_Ant1_2480_0~Reference
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 39 of 57

Report No.: CTC2024098406

BLE_1M_Ant1_2480_30~1000
BLE_1M_Ant1_2480_1000~26500
BLE_2M_Ant1_2402_0~Reference
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 40 of 57

Report No.: CTC2024098406

BLE_2M_Ant1_2402_30~1000
BLE_2M_Ant1_2402_1000~26500
BLE_2M_Ant1_2440_0~Reference
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 41 of 57

Report No.: CTC2024098406

BLE_2M_Ant1_2440_30~1000
BLE_2M_Ant1_2440_1000~26500
BLE_2M_Ant1_2480_0~Reference
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 42 of 57

Report No.: CTC2024098406

BLE_2M_Ant1_2480_30~1000 BLE_2M_Ant1_2480_1000~26500

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 43 of 57

3.5. DTS Bandwidth

Limit FCC CFR Title 47 Part 15 Subpart C Section 15.247 (a)(2)

Test Item DTS Bandwidth

Limit
500 kHz (6dB bandwidth)

Test Configuration

Report No.: CTC2024098406
Frequency Range (MHz)
2400~2483.5

Test Procedure
1. The EUT was directly connected to the spectrum analyzer and antenna output port as show in the block diagram above.
2. DTS Spectrum Setting: (1) Set RBW = 100 kHz. (2) Set the video bandwidth (VBW)  3 RBW. (3) Detector = Peak. (4) Trace mode = Max hold. (5) Sweep = Auto couple. OCB Spectrum Setting: (1) Set RBW = 1% ~ 5% occupied bandwidth. (2) Set the video bandwidth (VBW)  3 RBW. (3) Detector = Peak. (4) Trace mode = Max hold. (5) Sweep = Auto couple.
NOTE: The EUT was set to continuously transmitting in each mode and low, Middle and high channel for the test.
Test Mode
Please refer to the clause 2.4.

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 44 of 57

Test Result 99% Bandwidth:
TestMode Antenna

BLE_1M

Ant1

BLE_2M

Ant1

Freq(MHz)
2402 2440 2480 2402 2440 2480

OCB [MHz]
1.0721 1.0973 1.0805 2.1114 2.1157 2.1173

DTS Bandwidth:
TestMode Antenna

BLE_1M

Ant1

BLE_2M

Ant1

Freq(MHz)
2402 2440 2480 2402 2440 2480

DTS BW [MHz]
0.624 0.680 0.648 1.092 1.332 1.072

FL[MHz] 2401.2641 2439.2430 2479.2499 2400.7429 2438.7385 2478.7350
FL[MHz] 2401.480 2439.464 2479.468 2401.264 2439.108 2479.240

Report No.: CTC2024098406

FH[MHz]
2402.3362 2440.3403 2480.3304 2402.8543 2440.8542 2480.8523

Limit[MHz]
-------------

Verdict
-------------

FH[MHz]
2402.104 2440.144 2480.116 2402.356 2440.440 2480.312

Limit[MHz]
0.5 0.5 0.5 0.5 0.5 0.5

Verdict
PASS PASS PASS PASS PASS PASS

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

99% Bandwidth:

Page 45 of 57
BLE_1M_Ant1_2402

Report No.: CTC2024098406

BLE_1M_Ant1_2440

BLE_1M_Ant1_2480

BLE_2M_Ant1_2402
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 46 of 57

Report No.: CTC2024098406

BLE_2M_Ant1_2440 BLE_2M_Ant1_2480

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

DTS Bandwidth:

Page 47 of 57
BLE_1M_Ant1_2402

Report No.: CTC2024098406

BLE_1M_Ant1_2440

BLE_1M_Ant1_2480

BLE_2M_Ant1_2402
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 48 of 57

Report No.: CTC2024098406

BLE_2M_Ant1_2440 BLE_2M_Ant1_2480

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 49 of 57

Report No.: CTC2024098406

3.6. Output Power

Limit

FCC CFR Title 47 Part 15 Subpart C Section 15.247 (b)(3)

Section
FCC CFR 47 Part15.247 (b)(3)

Test Item
Maximum Conducted Output Power

Limit 1 Watt or 30dBm

Test Configuration

Frequency Range (MHz)
2400~2483.5

Test Procedure
1. The maximum conducted output power may be measured using a broadband RF power meter. 2. Power measurements were performed only when the EUT was transmitting at its maximum power
control level using a broadband power meter with a pulse sensor. 3. The power meter implemented triggering and gating capabilities which were set up such that power
measurements were recorded only during the ON time of the transmitter. 4. Record the measurement data.

Test Mode Please refer to the clause 2.4.

Test Result

TestMode BLE_1M BLE_2M

Antenna Ant1 Ant1

Freq(MHz)
2402 2440 2480 2402 2440 2480

AV Conducted Power[dBm]
9.89 7.04 7.33 7.89 8.23 8.31

Conducted Limit[dBm]
30 30 30 30 30 30

Verdict
PASS PASS PASS PASS PASS PASS

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 50 of 57

3.7. Power Spectral Density

Limit

FCC CFR Title 47 Part 15 Subpart C Section 15.247 (e)

Test Item Power Spectral Density

Limit 8 dBm (in any 3 kHz)

Test Configuration

Report No.: CTC2024098406
Frequency Range (MHz)
2400~2483.5

Test Procedure
1. The EUT was directly connected to the spectrum analyzer and antenna output port as show in the block diagram above.
2. The EUT was directly connected to the Spectrum Analyzer and antenna output port as show in the block diagram above. The measurement according to section 10.2 of KDB 558074 D01 DTS Meas Guidance v05r02. 3. Spectrum Setting: Measure the duty cycle (D) of the transmitter output signal as described in 11.6. b) Set instrument center frequency to DTS channel center frequency. c) Set span to at least 1.5 times the OBW. d) Set RBW to: 3 kHz  RBW  100 kHz. e) Set VBW  [3 × RBW]. f) Detector = power averaging (rms) or sample detector (when rms not available). g) Ensure that the number of measurement points in the sweep  [2 × span / RBW]. h) Sweep time = auto couple. i) Do not use sweep triggering; allow sweep to "free run." j) Employ trace averaging (rms) mode over a minimum of 100 traces. k) Use the peak marker function to determine the maximum amplitude level. l) Add [10 log (1 / D)], where D is the duty cycle measured in step a), to the measured PSD to compute the average PSD during the actual transmission time. m) If measured value exceeds requirement specified by regulatory agency, then reduce RBW (but no less than 3 kHz) and repeat (note that this may require zooming in on the emission of interest and reducing the span to meet the minimum measurement point requirement as the RBW is reduced). Test Mode
Please refer to the clause 2.4.
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Test Result
TestMode BLE_1M BLE_2M

Antenna Ant1 Ant1

Page 51 of 57

Report No.: CTC2024098406

Freq(MHz)
2402 2440 2480 2402 2440 2480

AV Result [dBm/3kHz]
-9.33 -11.02 -11.80 -12.98 -12.86 -13.24

Limit[dBm/3kHz]
8.00 8.00 8.00 8.00 8.00 8.00

Verdict
PASS PASS PASS PASS PASS PASS

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Test plot as follows:

Page 52 of 57
BLE_1M_Ant1_2402

Report No.: CTC2024098406

BLE_1M_Ant1_2440

BLE_1M_Ant1_2480

BLE_2M_Ant1_2402
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 53 of 57

Report No.: CTC2024098406

BLE_2M_Ant1_2440 BLE_2M_Ant1_2480

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

3.8. Duty Cycle
Limit None, for report purposes only. Test Configuration

Page 54 of 57

Report No.: CTC2024098406

Test Procedure
1. The EUT was directly connected to the spectrum analyzer and antenna output port as show in the block diagram above.
2. The EUT was directly connected to the Spectrum Analyzer and antenna output port as show in the block diagram above. The measurement according to section 10.2 of KDB 558074 D01 DTS Meas Guidance v05r02. 3. Spectrum Setting: Set analyzer center frequency to test channel center frequency. Set the span to 0Hz. Set the RBW to 10MHz. Set the VBW to 10MHz. Detector: Peak. Sweep time: Auto.
Allow trace to fully stabilize. Then use the peak marker function to determine the maximum amplitude level.

Test Mode Please refer to the clause 2.4.

Test Result Test Mode BLE_1M BLE_2M

Frequency (MHz)
2402 2440 2480 2402 2440 2480

Transmission Duration (ms)
2.10 2.10 2.10 1.07 1.06 1.06

Transmission Period (ms)
2.51 2.50 2.50 1.88 1.87 1.87

Duty Cycle (%)
83.67 84.00 84.00 56.91 56.68 56.68

1/T Minimum VBW
(kHz) 0.48 0.48 0.48 0.93 0.94 0.94

Final Setting for VBW (kHz) 1 1 1 1 1 1

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Test plot as follows:

Page 55 of 57
BLE_1M_Ant1_2402

Report No.: CTC2024098406

BLE_1M_Ant1_2440

BLE_1M_Ant1_2480

BLE_2M_Ant1_2402
CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 56 of 57

Report No.: CTC2024098406

BLE_2M_Ant1_2440 BLE_2M_Ant1_2480

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn

Page 57 of 57

Report No.: CTC2024098406

3.9. Antenna Requirement
Requirement
FCC CFR Title 47 Part 15 Subpart C Section 15.203 An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited. FCC CFR Title 47 Part 15 Subpart C Section 15.247(c) (1)(i) (i) Systems operating in the 2400~2483.5 MHz band that is used exclusively for fixed. Point-to-point operations may employ transmitting antennas with directional gain greater than 6dBi provided the maximum conducted output power of the intentional radiator is reduced by 1 dB for every 3 dB that the directional gain of the antenna exceeds 6dBi.
Test Result
The directional gain of the antenna is less than 6dBi, please refer to the EUT internal photographs antenna photo.

**********************THE END**********************

CTC Laboratories, Inc. Room 101 Building B, No. 7, Lanqing 1st Road, Luhu Community, Guanhu Subdistrict, Longhua District, Shenzhen, Guangdong, China
Tel.: (86)755-27521059 Fax: (86)755-27521011 Http://www.sz-ctc.org.cn For anti-fake verification, please visit the official website of Certification and Accreditation Administration of the People's Republic of China : http://yz.cnca.cn



Related FCC IDs: