ETR2201780-03 900MHz TxRx Part2

Chamberlain Group Inc, The 0458X2 MyQ - Garage Door Opener HBW0458X2 HBW0458X2 0458x2

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 32 Pages, 2.45MB

Document DEVICE REPORTGetApplicationAttachment.html?id=5992503
Engineering Test Report No. 2201780-03

Manufacturer EUT Model No. Serial No. Mode Frequency Tested Result Notes

Test Details Chamberlain Phoenix AC GDO Logic Board 003-0458-5 151220510865 Tx Low @ 902.25MHz 902.25MHz On Time = 1.27ms 29 Pulses

Page 65 of 96

Engineering Test Report No. 2201780-03

Manufacturer EUT Model No. Serial No. Mode Frequency Tested Result Notes

Test Details Chamberlain Phoenix AC GDO Logic Board 003-0458-5 151220510865 Tx Low @ 902.25MHz 902.25MHz On Time = 0.7ms 1 Pulse

Page 66 of 96

Engineering Test Report No. 2201780-03

Manufacturer EUT Model No. Serial No. Mode Frequency Tested Result
Notes

Test Details

Chamberlain

Phoenix AC GDO Logic Board

003-0458-5

151220510865

Tx Low @ 902.25MHz

902.25MHz

Duty Cycle = 41.3%

Duty Cycle Factor Calculation:

29 × 1.4ms = 40.6ms

1 × 0.7ms = 0.7ms

40.6ms + 0.7ms = 41.3ms

41.3ms

Duty Cycle Factor = 20 log

= -8.512

100ms

Page 67 of 96

Engineering Test Report No. 2201780-03

30. Case Spurious Radiated Emissions

Manufacturer Product Model No. Serial No.
Mode

EUT Information Chamberlain Phoenix AC GDO Logic Board 003-0458-5 151220510865 Tx Low @ 902.25MHz Tx Mid @ 914.75MHz Tx High @ 926.75MHz

Setup Format Height of Support Type of Test Site Test Site Used
Type of Antennas Used
Notes

Test Setup Details Tabletop N/a Semi-Anechoic Chamber Room 21 Below 1GHz: Bilog (or equivalent) Above 1GHz: Double-Ridged Waveguide (or equivalent) N/A

Measurement Uncertainty

Measurement Type

Radiated disturbance (electric field strength on an open area test site or alternative test site) (30 MHz ­ 1000 MHz) Radiated disturbance (electric field strength on an open area test site or alternative test site) (1 GHz ­ 6 GHz) Radiated disturbance (electric field strength on an open area test site or alternative test site) (6 GHz ­ 18 GHz) Radiated disturbance (electric field strength on an open area test site or alternative test site) (18 GHz ­ 26.5 GHz) Radiated disturbance (electric field strength on an open area test site or alternative test site) (26.5 GHz ­ 40 GHz)

Expanded Measurement
Uncertainty 4.3
3.1
3.2
3.3
3.4

Page 68 of 96

Engineering Test Report No. 2201780-03
Procedure Radiated measurements were performed in a 32ft. x 20ft. x 14ft. high shielded enclosure. The shielded enclosure prevents emissions from other sources, such as radio and TV stations from interfering with the measurements. All powerlines and signal lines entering the enclosure pass through filters on the enclosure wall. The powerline filters prevent extraneous signals from entering the enclosure on these leads.
Preliminary radiated emissions tests were performed to determine the emission characteristics of the EUT. For the preliminary test, a broadband measuring antenna was positioned at a 3-meter distance from the EUT. The entire frequency range from 30MHz to 10.0GHz was investigated using a peak detector function.
The final open field emission tests were then manually performed over the frequency range of 30MHz to 10.0GHz.
1) For all harmonics not in the restricted bands, the following procedure was used:
a) The field strength of the fundamental was measured using a bilog antenna. The bilog antenna was positioned at a 3-meter distance from the EUT. The EUT was placed on a 80 cm high nonconductive stand. A peak detector with a resolution bandwidth of 100 kHz was used on the spectrum analyzer.
b) The field strengths of all of the harmonics not in the restricted band were then measured using a double-ridged waveguide antenna. The waveguide antenna was positioned at a 3-meter distance from the EUT. The EUT was placed on a 1.5-meter-high non-conductive stand. A peak detector with a resolution bandwidth of 100kHz was used on the spectrum analyzer.
c) To ensure that maximum or worst-case emission levels at the fundamental and harmonics were measured, the following steps were taken when measuring the fundamental emissions and the spurious emissions:
i) The EUT was rotated so that all of its sides were exposed to the receiving antenna.
ii) Since the measuring antenna is linearly polarized, both horizontal and vertical field components were measured.
iii) The measuring antenna was raised and lowered for each antenna polarization to maximize the readings.
iv) In instances where it was necessary to use a shortened cable between the measuring antenna and the spectrum analyzer, the measuring antenna was not raised or lowered to ensure maximized readings. Instead, the EUT was rotated through all axis to ensure the maximum readings were recorded for the EUT.
d) All harmonics not in the restricted bands must be at least 20dB below levels measured at the fundamental. However, attenuation below the general limits specified in §15.209(a) is not required.
2) For all emissions in the restricted bands, the following procedure was used:
a) The field strengths of all emissions below 1GHz were measured using a bi-log antenna. The bi-log antenna was positioned at a 3-meter distance from the EUT. The EUT was placed on an 80cm high non-conductive stand. A peak detector with a resolution bandwidth of 100 kHz was used on the spectrum analyzer.
b) The field strengths of all emissions above 1GHz were measured using a double-ridged waveguide antenna. The waveguide antenna was positioned at a 3-meter distance from the EUT. The EUT was placed on a 1.5-meter-high non-conductive stand. A peak detector with a resolution bandwidth of 1MHz was used on the spectrum analyzer.
c) To ensure that maximum or worst-case emission levels were measured, the following steps were taken when taking all measurements:
i) The EUT was rotated so that all of its sides were exposed to the receiving antenna.
ii) Since the measuring antenna is linearly polarized, both horizontal and vertical field components
Page 69 of 96

Engineering Test Report No. 2201780-03
were measured. iii) The measuring antenna was raised and lowered for each antenna polarization to maximize the
readings. iv) In instances where it was necessary to use a shortened cable between the measuring antenna
and the spectrum analyzer, the measuring antenna was not raised or lowered to ensure maximized readings. Instead, the EUT was rotated through all axis to ensure the maximum readings were recorded for the EUT. d) For all radiated emissions measurements below 1GHz, if the peak reading is below the limits listed in §15.209(a), no further measurements are required. If, however, the peak readings exceed the limits listed in §15.209(a), then the emissions are remeasured using a quasi-peak detector. e) For all radiated emissions measurements above 1GHz, the peak readings must comply with the §15.35(b) limits. §15.35(b) states that when average radiated emissions measurements are specified, there also is a limit on the peak level of the radiated emissions. The limit on the peak radio frequency emissions is 20dB above the maximum permitted average emission limit applicable to the equipment under test. Therefore, all peak readings above 1GHz must be no greater than 20dB above the limits specified in §15.209(a). f) Next, for all radiated emissions measurements above 1GHz, the resolution bandwidth was set to 1MHz. The analyzer was set to linear mode with a 10Hz video bandwidth in order to simulate an average detector. An average reading was taken. If the dwell time per channel of the hopping signal is less than 100msec, then the reading obtained with the 10Hz video bandwidth may be further adjusted by a duty cycle correction factor derived from 20*log(dwell time/100msec). These readings must be no greater than the limits specified in §15.209(a).
Page 70 of 96

Engineering Test Report No. 2201780-03
Test Setup for Spurious Radiated Emissions, 30MHz ­ 1GHz ­ Antenna Polarization Horizontal
Test Setup for Spurious Radiated Emissions, 30MHz ­ 1GHz ­ Antenna Polarization Vertical Page 71 of 96

Engineering Test Report No. 2201780-03
Test Setup for Spurious Radiated Emissions, Above 1GHz ­ Antenna Polarization Horizontal
Test Setup for Spurious Radiated Emissions, Above 1GHz ­ Antenna Polarization Vertical Page 72 of 96

Engineering Test Report No. 2201780-03

Manufacturer EUT Model No. Serial No. Mode Frequency Tested Notes

Test Details Chamberlain Phoenix AC GDO Logic Board 003-0458-5 151220510865 Tx Low @ 902.25MHz 902.25MHz Peak Measurements in the Restricted Bands

Freq (MHz)

Peak

Peak Peak

Meter

Cable Antenna Pre

Total

Total

Limit

Ant Reading

Factor Factor Amp

at 3m at 3m at 3m Margin

Pol (dBV) Ambient (dB) (dB/m) (dB) (dBV/m) (V/m) (V/m) (dBm)

H

51.4

2706.75

V

55.6

3.7

32.6

-40.4

47.3

231.0 5000.0 -26.7

3.7

32.6

-40.4

51.4

372.4 5000.0 -22.6

H

57.2

3609.00

V

57.7

4.3

33.2

-40.3

54.4

523.9 5000.0 -19.6

4.3

33.2

-40.3

54.8

551.1 5000.0 -19.2

H

52.2

4511.25

V

49.3

*

4.7

34.2

-40.1

50.9

352.5 5000.0 -23.0

4.7

34.2

-40.1

48.0

252.5 5000.0 -25.9

H

59.2

5413.50

V

58.4

5.1

35.0

-40.2

59.1

902.5 5000.0 -14.9

5.1

35.0

-40.2

58.3

825.0 5000.0 -15.7

H

48.6

*

8120.25

V

48.8

*

6.5

35.8

-40.0

50.9

351.7 5000.0 -23.1

6.5

35.8

-40.0

51.1

360.7 5000.0 -22.8

H

49.7

*

9022.50

V

49.6

*

6.5

36.3

-39.7

52.8

435.6 5000.0 -21.2

6.5

36.3

-39.7

52.7

429.1 5000.0 -21.3

Page 73 of 96

Engineering Test Report No. 2201780-03

Manufacturer EUT Model No. Serial No. Mode Frequency Tested Notes

Test Details Chamberlain Phoenix AC GDO Logic Board 003-0458-5 151220510865 Tx Low @ 902.25MHz 902.25MHz Average Measurements in the Restricted Bands

Freq (MHz)

Duty Average Average Average

Meter

CBL Ant Pre Cycle Total

Total

Limit

Ant Reading

Fac Fac Amp Factor at 3m

at 3m at 3m Margin

Pol (dBV) Ambient (dB) (dB/m) (dB) (dB) (dBV/m) (V/m) (V/m) (dB)

H 2706.75
V

43.00 43.90

3.7 32.6 -40.4 -8.5

30.3

3.7 32.6 -40.4 -8.5

31.2

32.8

500.0 -23.7

36.4

500.0 -22.8

H 3609.00
V

46.30 46.60

4.3 33.2 -40.3 -8.5

35.0

4.3 33.2 -40.3 -8.5

35.3

55.9

500.0 -19.0

57.9

500.0 -18.7

H

38.30

4.7 34.2 -40.1 -8.5

28.6

26.8

500.0 -25.4

4511.25

V

34.30

*

4.7 34.2 -40.1 -8.5

24.6

16.9

500.0 -29.4

H 5413.50
V

48.10 47.00

5.1 35.0 -40.2 -8.5

39.5

5.1 35.0 -40.2 -8.5

38.4

94.2

500.0 -14.5

83.0

500.0 -15.6

H

34.40

*

6.5 35.8 -40.0 -8.5

28.2

25.7

500.0 -25.8

8120.25

V

34.20

*

6.5 35.8 -40.0 -8.5

28.0

25.2

500.0 -26.0

H

35.30

*

6.5 36.3 -39.7 -8.5

29.8

31.1

500.0 -24.1

9022.50

V

34.90

*

6.5 36.3 -39.7 -8.5

29.4

29.7

500.0 -24.5

Page 74 of 96

Engineering Test Report No. 2201780-03

Manufacturer EUT Model No. Serial No. Mode Frequency Tested Notes

Test Details Chamberlain Phoenix AC GDO Logic Board 003-0458-5 151220510865 Tx Low @ 902.25MHz 902.25MHz Peak Measurements in Non-Restricted Bands

Freq (MHz)

Peak

Peak

Peak

Meter

Cable Antenna Pre

Total

Total

Limit

Ant Reading

Factor Factor Amp

at 3m

at 3m at 3m Margin

Pol (dBV) Ambient (dB) (dB/m) (dB) (dBV/m) (V/m) (V/m) (dBm)

H 902.25
V

89.51 84.59

2.0

26.5

0.0

118.0 796248.6 NA

NA

2.0

26.5

0.0

113.1 451906.6 NA

NA

H 1804.50
V

72.91 71.97

2.9

30.9

-40.9

65.9

1964.8 79624.9 -32.2

2.9

30.9

-40.9

64.9

1763.3 79624.9 -33.1

H 6315.75
V

43.35 47.68

5.6

35.5

-40.2

44.3

164.2 79624.9 -53.7

5.6

35.5

-40.2

48.6

270.3 79624.9 -49.4

H 7218.00
V

43.48 39.83

6.1

35.7

-40.1

45.2

182.0 79624.9 -52.8

6.1

35.7

-40.1

41.6

119.6 79624.9 -56.5

Page 75 of 96

Engineering Test Report No. 2201780-03

Manufacturer EUT Model No. Serial No. Mode Frequency Tested Notes

Test Details Chamberlain Phoenix AC GDO Logic Board 003-0458-5 151220510865 Tx Mid @ 914.75MHz 914.75MHz Peak Measurements in the Restricted Bands

Freq (MHz)

Peak

Peak Peak

Meter

Cable Antenna Pre

Total

Total

Limit

Ant Reading

Factor Factor Amp

at 3m at 3m at 3m Margin

Pol (dBV) Ambient (dB) (dB/m) (dB) (dBV/m) (V/m) (V/m) (dBm)

H

56.4

2744.25

V

56.0

3.7

32.6

-40.4

52.3

412.8 5000.0 -21.7

3.7

32.6

-40.4

51.9

391.5 5000.0 -22.1

H

58.1

3659.00

V

56.8

4.3

33.2

-40.3

55.3

583.9 5000.0 -18.7

4.3

33.2

-40.3

54.0

503.3 5000.0 -19.9

H

50.5

4573.75

V

49.3

*

4.7

34.3

-40.1

49.4

295.1 5000.0 -24.6

4.7

34.3

-40.1

48.2

258.5 5000.0 -25.7

H

50.3

7318.00

V

49.5

6.2

35.7

-40.1

52.1

400.9 5000.0 -21.9

6.2

35.7

-40.1

51.3

365.2 5000.0 -22.7

H

49.0

8232.75

V

48.1

*

6.5

35.9

-39.9

51.4

371.2 5000.0 -22.6

6.5

35.9

-39.9

50.6

337.7 5000.0 -23.4

H

50.2

9147.50

V

49.3

6.6

36.3

-39.7

53.4

468.1 5000.0 -20.6

6.6

36.3

-39.7

52.5

420.1 5000.0 -21.5

Page 76 of 96

Engineering Test Report No. 2201780-03

Manufacturer EUT Model No. Serial No. Mode Frequency Tested Notes

Test Details Chamberlain Phoenix AC GDO Logic Board 003-0458-5 151220510865 Tx Mid @ 914.75MHz 914.75MHz Average Measurements in the Restricted Bands

Freq (MHz)

Duty Average Average Average

Meter

CBL Ant Pre Cycle Total

Total

Limit

Ant Reading

Fac Fac Amp Factor at 3m

at 3m at 3m Margin

Pol (dBV) Ambient (dB) (dB/m) (dB) (dB) (dBV/m) (V/m) (V/m) (dB)

H 2744.25
V

45.40 44.70

3.7 32.6 -40.4 -8.5

32.8

3.7 32.6 -40.4 -8.5

32.1

43.6

500.0 -21.2

40.2

500.0 -21.9

H 3659.00
V

47.20 45.60

4.3 33.2 -40.3 -8.5

35.9

4.3 33.2 -40.3 -8.5

34.3

62.4

500.0 -18.1

51.9

500.0 -19.7

H

36.80

4.7 34.3 -40.1 -8.5

27.2

23.0

500.0 -26.8

4573.75

V

34.80

*

4.7 34.3 -40.1 -8.5

25.2

18.2

500.0 -28.8

H 7318.00
V

35.10 35.60

6.2 35.7 -40.1 -8.5

28.4

6.2 35.7 -40.1 -8.5

28.9

26.3

500.0 -25.6

27.8

500.0 -25.1

H

33.60

6.5 35.9 -39.9 -8.5

27.5

23.8

500.0 -26.5

8232.75

V

33.50

*

6.5 35.9 -39.9 -8.5

27.4

23.5

500.0 -26.6

H 9147.50
V

35.70 35.00

6.6 36.3 -39.7 -8.5

30.4

6.6 36.3 -39.7 -8.5

29.7

33.1

500.0 -23.6

30.5

500.0 -24.3

Page 77 of 96

Engineering Test Report No. 2201780-03

Manufacturer EUT Model No. Serial No. Mode Frequency Tested Notes

Test Details Chamberlain Phoenix AC GDO Logic Board 003-0458-5 151220510865 Tx Mid @ 914.75MHz 914.75MHz Peak Measurements in Non-Restricted Bands

Freq (MHz)

Peak

Peak

Peak

Meter

Cable Antenna Pre

Total

Total

Limit

Ant Reading

Factor Factor Amp

at 3m

at 3m at 3m Margin

Pol (dBV) Ambient (dB) (dB/m) (dB) (dBV/m) (V/m) (V/m) (dBm)

H 914.75
V

87.40 87.79

2.1

26.4

0.0

115.8 618396.6 NA

NA

2.1

26.4

0.0

116.2 646795.6 NA

NA

H 1829.50
V

69.05 71.17

2.9

30.9

-40.8

62.1

1272.0 64679.6 -34.1

2.9

30.9

-40.8

64.2

1623.6 64679.6 -32.0

H 5488.50
V

61.12 57.22

5.2

35.0

-40.2

61.1

1129.3 64679.6 -35.2

5.2

35.0

-40.2

57.2

720.8 64679.6 -39.1

Page 78 of 96

Engineering Test Report No. 2201780-03

Manufacturer EUT Model No. Serial No. Mode Frequency Tested Notes

Test Details Chamberlain Phoenix AC GDO Logic Board 003-0458-5 151220510865 Tx High @ 926.75MHz 926.75MHz Peak Measurements in the Restricted Bands

Freq (MHz)

Peak

Peak Peak

Meter

Cable Antenna Pre

Total

Total

Limit

Ant Reading

Factor Factor Amp

at 3m at 3m at 3m Margin

Pol (dBV) Ambient (dB) (dB/m) (dB) (dBV/m) (V/m) (V/m) (dBm)

H

54.2

2780.25

V

54.8

3.7

32.5

-40.4

50.0

317.5 5000.0 -23.9

3.7

32.5

-40.4

50.6

340.2 5000.0 -23.3

H

58.4

3707.00

V

54.4

4.3

33.2

-40.2

55.7

608.8 5000.0 -18.3

4.3

33.2

-40.2

51.6

382.4 5000.0 -22.3

H

50.0

*

4633.75

V

50.2

*

4.8

34.5

-40.2

49.1

285.3 5000.0 -24.9

4.8

34.5

-40.2

49.3

290.2 5000.0 -24.7

H

49.5

7414.00

V

48.5

*

6.2

35.6

-40.0

51.3

367.8 5000.0 -22.7

6.2

35.6

-40.0

50.3

326.7 5000.0 -23.7

H

48.4

*

8340.75

V

48.0

*

6.5

35.9

-39.9

50.9

352.7 5000.0 -23.0

6.5

35.9

-39.9

50.5

335.3 5000.0 -23.5

Page 79 of 96

Engineering Test Report No. 2201780-03

Manufacturer EUT Model No. Serial No. Mode Frequency Tested Notes

Test Details Chamberlain Phoenix AC GDO Logic Board 003-0458-5 151220510865 Tx High @ 926.75MHz 926.75MHz Average Measurements in the Restricted Bands

Freq (MHz)

Duty Average Average Average

Meter

CBL Ant Pre Cycle Total

Total

Limit

Ant Reading

Fac Fac Amp Factor at 3m

at 3m at 3m Margin

Pol (dBV) Ambient (dB) (dB/m) (dB) (dB) (dBV/m) (V/m) (V/m) (dB)

H 2780.25
V

42.40 42.70

3.7 32.5 -40.4 -8.5

29.8

3.7 32.5 -40.4 -8.5

30.1

30.8

500.0 -24.2

31.9

500.0 -23.9

H 3707.00
V

47.80 42.40

4.3 33.2 -40.2 -8.5

36.6

4.3 33.2 -40.2 -8.5

31.2

67.4

500.0 -17.4

36.2

500.0 -22.8

H

35.70

*

4.8 34.5 -40.2 -8.5

26.3

20.6

500.0 -27.7

4633.75

V

34.60

*

4.8 34.5 -40.2 -8.5

25.2

18.1

500.0 -28.8

H

34.70

6.2 35.6 -40.0 -8.5

28.0

25.1

500.0 -26.0

7414.00

V

34.30

*

6.2 35.6 -40.0 -8.5

27.6

24.0

500.0 -26.4

H

33.40

*

6.5 35.9 -39.9 -8.5

27.4

23.4

500.0 -26.6

8340.75

V

33.20

*

6.5 35.9 -39.9 -8.5

27.2

22.9

500.0 -26.8

Page 80 of 96

Engineering Test Report No. 2201780-03

Manufacturer EUT Model No. Serial No. Mode Frequency Tested Notes

Test Details Chamberlain Phoenix AC GDO Logic Board 003-0458-5 151220510865 Tx High @ 926.75MHz 926.75MHz Peak Measurements in Non-Restricted Bands

Freq (MHz)

Peak

Peak

Peak

Meter

Cable Antenna Pre

Total

Total

Limit

Ant Reading

Factor Factor Amp

at 3m

at 3m at 3m Margin

Pol (dBV) Ambient (dB) (dB/m) (dB) (dBV/m) (V/m) (V/m) (dBm)

H 926.75
V

88.35 86.26

2.1

26.8

0.0

117.2 722570.7 NA

NA

2.1

26.8

0.0

115.1 568041.9 NA

NA

H 1853.50
V

69.55 69.38

3.0

31.0

-40.8

62.7

1365.6 72257.1 -34.5

3.0

31.0

-40.8

62.5

1339.1 72257.1 -34.6

H 5560.50
V

61.81 61.55

5.2

35.0

-40.2

61.8

1223.9 72257.1 -35.4

5.2

35.0

-40.2

61.5

1187.9 72257.1 -35.7

H 6487.25
V

40.85 45.28

5.7

35.6

-40.1

42.0

125.9 72257.1 -55.2

5.7

35.6

-40.1

46.4

209.7 72257.1 -50.7

H 9267.50
V

42.49 41.03

6.6

36.3

-39.7

45.8

194.9 72257.1 -51.4

6.6

36.3

-39.7

44.3

164.7 72257.1 -52.8

Page 81 of 96

Engineering Test Report No. 2201780-03

31. Band Edge Compliance

Manufacturer Product Model No. Serial No.
Mode

EUT Information Chamberlain Phoenix AC GDO Logic Board 003-0458-5 151220510865 Tx Low @ 902.25MHz Tx High @ 926.75MHz Tx Hopping

Setup Format Height of Support Measurement Method Type of Test Site Type of Antennas Used Notes

Test Setup Details Tabletop N/a Antenna Conducted Tabletop N/a Bench

Measurement Uncertainty
Measurement Type
Radiated disturbance (electric field strength on an open area test site or alternative test site) (30 MHz ­ 1000 MHz) Radiated disturbance (electric field strength on an open area test site or alternative test site) (1 GHz ­ 6 GHz)

Expanded Measurement
Uncertainty 4.3
3.1

Procedure
1) Low Band Edge: a) The antenna port of the EUT was connected to the spectrum analyzer through 30dB of attenuation. b) The EUT was set to transmit continuously at the channel closest to the low band-edge hopping function disabled. c) To determine the band edge compliance, the following spectrum analyzer settings were used: o Center Frequency = 902MHz (low band-edge frequency). o Span = Wide enough to capture the peak level of the emission operating on the channel closest to the band-edge, as well as any modulation products which fall outside of the authorized band of operation. o Resolution Bandwidth (RBW) =  1% of the span. o `Max-Hold' function was engaged. d) The analyzer was allowed to scan until the envelope of the transmitter bandwidth was defined. e) The marker was set on the peak of the in-band emissions. A display line was placed 20dB down from the peak of the in-band emissions. All emissions which fall outside of the authorized band of operation must be below the 20dB down display line. (All emissions to the left of the center frequency (band-edge) must be below the display line.) f) The analyzer's display was then screenshot and saved. g) Steps (d) through (f) were repeated with the frequency hopping function enabled.
2) High Band Edge:

Page 82 of 96

Engineering Test Report No. 2201780-03
a) The antenna port of the EUT was connected to the spectrum analyzer through 30dB of attenuation. b) The EUT was set to transmit continuously at the channel closest to the high band-edge hopping
function disabled. c) To determine the band edge compliance, the following spectrum analyzer settings were used:
o Center Frequency = 928MHz (high band-edge frequency). o Span = Wide enough to capture the peak level of the emission operating on the channel
closest to the band-edge, as well as any modulation products which fall outside of the authorized band of operation. o Resolution Bandwidth (RBW) =  1% of the span. o `Max-Hold' function was engaged. d) The analyzer was allowed to scan until the envelope of the transmitter bandwidth was defined. e) The marker was set on the peak of the in-band emissions. A display line was placed 20dB (30dB for DTS systems where average power was used) down from the peak of the in-band emissions. All emissions which fall outside of the authorized band of operation must be below the 20dB (30dB for DTS systems where average power was used) down display line. (All emissions to the left of the center frequency (band-edge) must be below the display line.) f) The analyzer's display was then screenshot and saved. g) Steps (d) through (f) were repeated with the frequency hopping function enabled.
Page 83 of 96

Engineering Test Report No. 2201780-03

Manufacturer EUT Model No. Serial No. Mode Frequency Tested Notes

Test Details Chamberlain Phoenix AC GDO Logic Board 003-0458-5 151220510865 Tx Low @ 902.25MHz 902.25MHz Low Band Edge (Antenna Conducted)

Page 84 of 96

Engineering Test Report No. 2201780-03

Manufacturer EUT Model No. Serial No. Mode Frequency Tested Notes

Test Details Chamberlain Phoenix AC GDO Logic Board 003-0458-5 151220510865 Tx Hopping n/a Low Band Edge (Antenna Conducted)

Page 85 of 96

Engineering Test Report No. 2201780-03

Manufacturer EUT Model No. Serial No. Mode Frequency Tested Notes

Test Details Chamberlain Phoenix AC GDO Logic Board 003-0458-5 151220510865 Tx High @ 926.75MHz 926.75MHz High Band Edge (Antenna Conducted)

Page 86 of 96

Engineering Test Report No. 2201780-03

Manufacturer EUT Model No. Serial No. Mode Frequency Tested Notes

Test Details Chamberlain Phoenix AC GDO Logic Board 003-0458-5 151220510865 Tx Hopping n/a High Band Edge (Antenna Conducted)

Page 87 of 96

32. Scope of Accreditation

Engineering Test Report No. 2201780-03

Page 88 of 96

Engineering Test Report No. 2201780-03 Page 89 of 96

Engineering Test Report No. 2201780-03 Page 90 of 96

Engineering Test Report No. 2201780-03 Page 91 of 96

Engineering Test Report No. 2201780-03 Page 92 of 96

Engineering Test Report No. 2201780-03 Page 93 of 96

Engineering Test Report No. 2201780-03 Page 94 of 96

Engineering Test Report No. 2201780-03 Page 95 of 96

Engineering Test Report No. 2201780-03 Page 96 of 96



Related FCC IDs:

Search Any Device: