Test Report No.: W7L-211129W002EM03

Applicant: Address:

VARIANT EMC TEST REPORT
Honeywell International Inc Honeywell Safety and Productivity Solutions
9680 Old Bailes Road, Fort Mill, SC 29707 United States

Manufacturer or Supplier:
Address:

Honeywell International Inc Honeywell Safety and Productivity Solutions
9680 Old Bailes Road, Fort Mill, SC 29707 United States

Product:

Mobile Computer

Brand Name:

Honeywell

Model Name:

CT45P-L1N-2

FCC ID:

HD5-CT45PL1N2

Date of tests:

Nov. 29, 2021 ~ Dec. 13, 2021

The submitted sample of the above equipment has been tested for according to the requirements of the following standards:
FCC Part 15, Subpart B, Class A FCC Part 15, Subpart B, Class B ANSI C63.4:2014
CONCLUSION: The submitted sample was found to COMPLY with the test requirement

Prepared by Simon Wang Engineer / Mobile Department

Approved by Luke Lu Manager / Mobile Department

Date: Dec. 15, 2021

Date: Dec. 15, 2021

This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents.

BV 7Layers Communications Technology (Shenzhen) Co. Ltd

No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China
Page 1 of 23

Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected]
Report Version 1

Test Report No.: W7L-211129W002EM03
TABLE OF CONTENTS
RELEASE CONTROL RECORD ............................................................................................................... 3
1 GENERAL INFORMATION................................................................................................................. 4
1.1 GENERAL DESCRIPTION OF EUT............................................................................................. 4 1.2 SUMMARY OF TEST RESULTS.................................................................................................. 6 1.3 MEASUREMENT UNCERTAINTY ............................................................................................... 6 1.4 DESCRIPTION OF TEST MODES............................................................................................... 7 1.5 DESCRIPTION OF SUPPORT UNITS......................................................................................... 8
2 EMISSION TEST ................................................................................................................................ 9
2.1 CONDUCTED EMISSION MEASUREMENT.................................................................................... 9 2.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT.......................................................... 9 2.1.2 TEST INSTRUMENTS.......................................................................................................... 9 2.1.3 TEST PROCEDURES ........................................................................................................ 10 2.1.4 DEVIATION FROM TEST STANDARD .............................................................................. 10 2.1.5 TEST SETUP.......................................................................................................................11 2.1.6 EUT OPERATING CONDITIONS ........................................................................................11 2.1.7 TEST RESULTS ................................................................................................................. 12
2.2 RADIATED EMISSION MEASUREMENT.................................................................................. 14 2.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT ....................................................... 14 2.2.2 TEST INSTRUMENTS........................................................................................................ 15 2.2.3 TEST PROCEDURE........................................................................................................... 16 2.2.4 DEVIATION FROM TEST STANDARD .............................................................................. 17 2.2.5 TEST SETUP...................................................................................................................... 18 2.2.6 EUT OPERATING CONDITIONS ....................................................................................... 18 2.2.7 TEST RESULTS ................................................................................................................. 19
3 APPENDIX A ­ MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT BY THE LAB ............................................................................................................................................ 23

BV 7Layers Communications Technology (Shenzhen) Co. Ltd

No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China
Page 2 of 23

Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected]
Report Version 1

Test Report No.: W7L-211129W002EM03

RELEASE CONTROL RECORD

ISSUE NO. W7L- P21080006EM03 W7L- P21110008EM03
W7L-211129W002EM03

REASON FOR CHANGE Original release Based on the original report W7L- P21080006EM03 add the band 41C, changing components.
Based on the original report W7L- P21110008EM03 Changing components.

DATE ISSUED Sep. 01, 2021 Nov. 10, 2021
Dec. 15, 2021

BV 7Layers Communications Technology (Shenzhen) Co. Ltd

No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China
Page 3 of 23

Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected]
Report Version 1

Test Report No.: W7L-211129W002EM03
1 GENERAL INFORMATION 1.1 GENERAL DESCRIPTION OF EUT

PRODUCT

Mobile Computer

BRAND NAME

Honeywell

MODEL NAME

CT45P-L1N-2

NOMINAL VOLTAGE 3.85Vdc (Lithium-ion cell, battery)

BT_LE

GFSK

Bluetooth

GFSK, /4-DQPSK, 8DPSK

WLAN

DSSS, OFDM

MODULATION TYPE

GPS/GLONASS/B DS/ GALILEO

BPSK

GSM/GPRS/EDG E

GMSK, 8PSK

WCDMA

BPSK/QPSK

LTE

QPSK/16QAM/64QAM

OPERATING FREQUENCY

Bluetooth/BT_LE 2402MHz ~ 2480MHz

WLAN

2412 ~ 2472MHz for 11b/g/n(HT20/40) 5180 ~ 5240MHz, 5260 ~ 5320 MHz, 5500 ~ 5700MHz, 5745 ~ 5825 MHz for 11a/ n(HT20)/ n(HT40) / ac(VHT20)/ ac(VHT40) / ac(VHT80)

GPS/ GLONASS /BDS/ GALILEO

1559MHz ~ 1610MHz

GSM

824.2MHz ~ 848.8MHz (FOR GSM 850) 1850.2MHz ~ 1909.8MHz (FOR GSM 1900)

WCDMA

1852.4MHz ~ 1907.6MHz(FOR WCDMA Band 2)
1712.4MHz ~ 1752.6MHz(FOR WCDMA Band 4) 826.4MHz ~ 846.6MHz (FOR WCDMA Band 5)

1850.7MHz ~ 1909.3MHz (FOR LTE Band2)

1710.7MHz ~ 1754.3MHz (FOR LTE Band4)

824.7MHz ~ 848.3MHz (FOR LTE Band5)

2502.5MHz ~ 2567.5MHz (FOR LTE Band7)

LTE

2505.5MHz ~ 2564.7MHz (FOR LTE Band CA_7C) 699.7MHz ~ 715.3MHz (FOR LTE Band12)

779.5MHz ~ 784.5MHz (FOR LTE Band13)

790.5MHz ~ 795.5MHz (FOR LTE Band14)

706.5MHz ~ 713.5MHz (FOR LTE Band17)

1850.7MHz ~ 1914.3MHz (FOR LTE Band25)

BV 7Layers Communications Technology (Shenzhen) Co. Ltd

No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China
Page 4 of 23

Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected]
Report Version 1

Test Report No.: W7L-211129W002EM03

824.7MHz ~ 848.3MHz 2307.5MHz ~ 2312.5MHz 2572.5MHz ~ 2617.5MHz 2498.5MHz ~ 2687.5MHz 2499.3 MHz ~ 2686.7MHz 1710.7MHz ~ 1779.3MHz 665.5MHz ~ 695.5MHz

(FOR LTE Band26) (FOR LTE Band30) (FOR LTE Band38) (FOR LTE Band41) (FOR LTE Band CA_41C) (FOR LTE Band66)
(FOR LTE Band71)

HW VERSION

V1.0

SW VERSION

OS.11.002-HON.11.002

I/O PORTS
CABLE SUPPLIED ACCESSORY DEVICES

Refer to user's manual USB CUP: unshielded without ferrite, 1.25 meter Earphone cable: unshielded without ferrite, 1.27 meter
Refer to note as below

NOTE:

1. For a more detailed features description, please refer to the manufacturer's specifications or the user's manual.

2. This product includes the following Three SKU which hardware is exactly same, the difference is described as following, Sample 1 was full test, sample 2 verify the worst case,check worst case Radiated emission:

SAMPLE EUT CONFIGURATION INFORMATION

1

SKU ID:CT45-L1N-37D120G ,Assembled Scanner Imager: 7-S0703

2

SKU ID:CT45-L1N-38D120G ,Assembled Scanner Imager: 8 - N6803/S0803

SKU ID: CT45-L1N-37D220G , Assembled with Scanner: 7-S0703 for China Only with

3

Android non-GMS

3. For the test results, the EUT had been tested with all conditions. But only the worst case was shown in test report.

List of Accessory: ACCESSORIES
Battery

BRAND Honeywell

AC Adapter

HONOR

USB CUP

Honeywell

MODEL CT50-BTSC
ADS-12B-06 05010E
CT40-SN

SPECIFICATION Capacity3.85vdc 4020mAh
I/P:100-240Vac, 0.3A O/P: 5Vdc, 2A
Shielded, 1.25meter

Earphone LCD Panel

VIVO CASIL

N/A

Shielded, 1.27meter

CTM10801920T0 1

5.0" FHD(1928*1080)

BV 7Layers Communications Technology (Shenzhen) Co. Ltd

No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China
Page 5 of 23

Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected]
Report Version 1

Test Report No.: W7L-211129W002EM03

1.2 SUMMARY OF TEST RESULTS
The EUT has been tested according to the following specifications:

APPLIED STANDARD: FCC Part 15, Subpart B

Standard Section

Test Item

Result

FCC Part 15, Subpart B, Class B ANSI C63.4:2014

Conducted Test Radiated Emission Test (30MHz ~ 1GHz) Radiated Emission Test (Above 1GHz)

Compliance Compliance Compliance

NOTE : Per the change notice provide by manufactory, the difference is changing components. Therefore only verify the worse case and show the verify test data on this report. More test details please refer to the original report.

1.3 MEASUREMENT UNCERTAINTY

Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the EUT as specified in CISPR 16-4-2:

This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.

MEASUREMENT Conducted emissions

FREQUENCY 150kHz ~ 30MHz

UNCERTAINTY
±2.70dB

30MHz~1GMHz

±4.98dB

Radiated emissions

1GMHz ~6GMHz

±4.70dB

6GMHz ~18GMHz

±4.60dB

BV 7Layers Communications Technology (Shenzhen) Co. Ltd

No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China
Page 6 of 23

Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected]
Report Version 1

Test Report No.: W7L-211129W002EM03
1.4 DESCRIPTION OF TEST MODES

Test Mode
1 2 3 4 5 6 7 8 9 10 11

Test Condition
Radiated emission test
Adapter + USB cable + Front Camera On+GSM850 RX Adapter + USB cable + Back Camera On+ GSM850 RX Adapter + USB cable + MPG4 + Scanning+WCDMA 850 RX USB Link + Data Transmission + USB Cable + PC to EUT+LTE Band 5 RX USB Link + Data Transmission + USB Cable +PC to SD+ LTE Band 12 RX Adapter + Charger + Back Camera On + LTE Band 13 RX Adapter + Charger + Front Camera On + LTE Band 14 RX Adapter + Charger + MPG4 + Scanning + LTE Band 17 RX Charger + Data Transmission + PC to EUT + GSM850 RX Charger + Data Transmission + PC to SD+ GSM850 RX Earphone + MPG4+ GSM850 RX

Conducted emission test
1 Adapter + USB cable + Front Camera On+GSM850 RX 2 Adapter + USB cable + Back Camera On+ GSM850 RX 3 Adapter + USB cable + MPG4 + Scanning+WCDMA 850 RX 4 USB Link + Data Transmission + USB Cable + PC to EUT+LTE Band 5 RX 5 USB Link + Data Transmission + USB Cable +PC to SD+ LTE Band 12 RX 6 Adapter + Charger + Back Camera On + LTE Band 13 RX 7 Adapter + Charger + Front Camera On + LTE Band 14 RX 8 Adapter + Charger + MPG4 + Scanning + LTE Band 17 RX 9 Charger + Data Transmission + PC to EUT + GSM850 RX 10 Charger + Data Transmission + PC to SD+ GSM850 RX NOTE:The charger in the test mode is named USB CUP in the List of Accessory Tabe.
NOTE: 1. For conducted emission test, test mode 2 was the Worst case and only this mode was presented in
this report. 2. For radiated emission test, test mode 3 was the Worst case and only this mode was presented in this
report

BV 7Layers Communications Technology (Shenzhen) Co. Ltd

No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China
Page 7 of 23

Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected]
Report Version 1

Test Report No.: W7L-211129W002EM03

1.5 DESCRIPTION OF SUPPORT UNITS

The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests.

FOR All TESTS

NO.

PRODUCT

1

Laptop

2

Printer

Universal radio 3 communication
tester

BRAND Lenovo
HP

MODEL NO. Thnikpad L440 Hp LaserJet 1300

Rohde&Schw arz

CMW500

SERIAL NO. R90FTFKP CNSJF75989
N/A

FCC ID N/A N/A
N/A

NO. 1 N/A 2 N/A 3 N/A

SIGNAL CABLE DESCRIPTION OF THE ABOVE SUPPORT UNITS

BV 7Layers Communications Technology (Shenzhen) Co. Ltd

No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China
Page 8 of 23

Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected]
Report Version 1

Test Report No.: W7L-211129W002EM03

2 EMISSION TEST 2.1 CONDUCTED EMISSION MEASUREMENT

2.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT
TEST STANDARD: FCC Part 15, Subpart B (Section: 15.107 a CLASS B)

FREQUENCY OF EMISSION (MHz)
0.15 ~ 0.5 0.5 ~ 5 5 ~ 30

CONDUCTED LIMIT (dBµV)

Quasi-peak

Average

66 to 56 56 60

56 to 46 46 50

TEST STANDARD: FCC Part 15, Subpart B (Section: 15.107 b CLASS A)

FREQUENCY OF EMISSION (MHz)
0.15 ~ 0.5 0.5 ~ 30

CONDUCTED LIMIT (dBµV)

Quasi-peak

Average

79

66

73

60

NOTE: 1.The lower limit shall apply at the transition frequencies. 2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50MHz. 3. All emanations from a class A/B digital device or system, including any network of conductors and apparatus connected thereto, shall not exceed the level of field strengths specified above.

2.1.2 TEST INSTRUMENTS

Equipment

Manufacturer

EMI Test Receiver Rohde&Schwarz

EMC32 test software Rohde&Schwarz

LISN network

Rohde&Schwarz

Model No. ESR3 EMC32 ENV216

Serial No. 101900 NA 101922

Last Cal. Mar. 03,21 NA Feb. 25,21

Next Cal. Mar. 02, 22 NA Feb. 24, 22

NOTE: 1. The test was performed in CE shielded room. .

BV 7Layers Communications Technology (Shenzhen) Co. Ltd

No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China
Page 9 of 23

Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected]
Report Version 1

Test Report No.: W7L-211129W002EM03
2.1.3 TEST PROCEDURES
a. The EUT was placed 0.4 meters from the conducting wall of the shielded room with EUT being connected to the power mains through a line impedance stabilization network (LISN). Other support units were connected to the power mains through another LISN. The two LISNs provide 50 ohm/ 50uH of coupling impedance for the measuring instrument.
b. Both lines of the power mains connected to the EUT were checked for maximum conducted interference.
c. The frequency range from 150 kHz to 30MHz was searched. Emission levels under (Limit - 20dB) were not recorded.
NOTE: All modes of operation were investigated and the worst-case emissions are reported.
2.1.4 DEVIATION FROM TEST STANDARD
No deviation.

BV 7Layers Communications Technology (Shenzhen) Co. Ltd

No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China
Page 10 of 23

Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected]
Report Version 1

Test Report No.: W7L-211129W002EM03
2.1.5 TEST SETUP

40cm

Vertical G ro und R eferen ce P lane
EUT

Test R eceiver

LIS N

80cm

H o rizo n tal G ro u n d R eferen ce P lan e
N o te: 1.S u p p o rt u n its w ere co n n ected to s eco n d L IS N . 2.B oth of LIS N s (AM N ) are 80 cm from E U T an d at least 80 fro m o th er u n its an d o th er m etal p lan es

For the actual test configuration, please refer to the attached file (Test Setup Photo).
2.1.6 EUT OPERATING CONDITIONS
a. Turned on the power and connected of all equipment. b. EUT was operated according to the use type described in the manufacturer's
specifications or the user's manual.

BV 7Layers Communications Technology (Shenzhen) Co. Ltd

No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China
Page 11 of 23

Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected]
Report Version 1

Test Report No.: W7L-211129W002EM03
2.1.7 TEST RESULTS
Acceleromete alternative 1 worst case:

TEST VOLTAGE
ENVIRONMENTAL CONDITIONS

Input 120 Vac, 60 Hz 25deg. C, 55%RH

Detector Function & Quasi-Peak (QP) / Resolution Bandwidth Average (AV), 9 kHz

TESTED BY

Carl xie

Frequency (MHz)
0.260000 0.260000 0.496000 0.496000 0.888000 0.888000 1.744000 1.744000 2.956000 2.956000 20.400000 20.400000

QuasiPeak (dBuV)
--33.61
--36.73
--29.11
--28.24
--22.87
--29.90

CAverage (dBuV)
22.63 ---
26.57 ---
18.57 ---
21.58 ---
15.30 ---
18.54 ---

Limit (dBuV)
51.43 61.43 46.07 56.07 46.00 56.00 46.00 56.00 46.00 56.00 50.00 60.00

Margin (dB)
28.80 27.82 19.50 19.34 27.43 26.89 24.42 27.76 30.70 33.13 31.46 30.10

Line
L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1 L1

Filter
ON ON ON ON ON ON ON ON ON ON ON ON

Corr. (dB)
9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.7 9.8 9.8

REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually. 2. "-": The Quasi-peak reading value also meets average limit and measurement with the average detector is unnecessary. 3. The emission levels of other frequencies were very low against the limit. 4. Margin value = Limit value - Emission level 5. Correction factor = Insertion loss + Cable loss 6. Emission Level = Correction Factor + Reading Value.

Level in dB

80 70 60 50 40 30 20 10
0 150k

Full Spectrum

Class B_QP Class B_AV

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

BV 7Layers Communications Technology (Shenzhen) Co. Ltd

No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China
Page 12 of 23

Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected]
Report Version 1

Test Report No.: W7L-211129W002EM03

TEST VOLTAGE Input 120 Vac, 60 Hz

ENVIRONMENTAL CONDITIONS

25deg. C, 55%RH

Detector Function & Quasi-Peak (QP) / Resolution Bandwidth Average (AV), 9 kHz

TESTED BY

Carl xie

Frequency (MHz)
0.488000 0.488000 1.116000 1.116000 1.608000 1.608000 2.572000 2.572000 4.168000 4.168000 20.072000 20.072000

QuasiPeak (dBuV)
--40.58
--32.11
--32.02
--30.74
--29.71
--31.02

CAverage (dBuV)
28.04 ---
21.82 ---
21.79 ---
20.38 ---
19.21 ---
20.13 ---

Limit (dBuV)
46.20 56.20 46.00 56.00 46.00 56.00 46.00 56.00 46.00 56.00 50.00 60.00

Margin (dB)
18.16 15.62 24.18 23.89 24.21 23.98 25.62 25.26 26.79 26.29 29.87 28.98

Line
N N N N N N N N N N N N

Filter
ON ON ON ON ON ON ON ON ON ON ON ON

Corr. (dB)
9.7 9.7 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.8 9.9 9.9

REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually. 2. "-": The Quasi-peak reading value also meets average limit and measurement with the average detector is unnecessary. 3. The emission levels of other frequencies were very low against the limit. 4. Margin value = Limit value - Emission level 5. Correction factor = Insertion loss + Cable loss 6. Emission Level = Correction Factor + Reading Value.

Level in dB

80 70 60 50 40 30 20 10
0 150k

Full Spectrum

Class B_QP Class B_AV

300 400 500

800 1M

2M 3M 4M 5M 6 Frequency in Hz

8 10M

20M 30M

BV 7Layers Communications Technology (Shenzhen) Co. Ltd

No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China
Page 13 of 23

Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected]
Report Version 1

Test Report No.: W7L-211129W002EM03

2.2 RADIATED EMISSION MEASUREMENT
2.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT
TEST STANDARD: FCC Part 15, Subpart B (Section: 15.109) Emissions radiated outside of the specified bands, shall be according to the general radiated limits as following:

Radiated Emissions Limits at 3 meters (dBV/m)

Frequencies (MHz) 30-88 88-216
216-960
960-1000 Above 1000

FCC 15B / ICES-003, Class A 49 53.5
56
59.5
Avg: 59.5 Peak: 79.5

FCC 15B / ICES-003, Class B 40 43.5
46
54
Avg: 54 Peak: 74

Frequency Range (For unintentional radiators) Highest frequency generated or used in the device or on which the device operates or tunes (MHz) Below 1.705 1.705-108 108-500 500-1000
Above 1000

Upper frequency of measurement range (MHz)
30 1000 2000 5000 5th harmonic of the highest frequency or 40GHz, whichever is lower

NOTE: 1. The lower limit shall apply at the transition frequencies. 2. Emission level (dBuV/m) = 20 log Emission level (uV/m). 3. As shown in 15.35(b), for frequencies above 1000MHz, the field strength limits are based on average detector, however, the peak field strength of any emission shall not exceed the maximum permitted average limits, specified above by more than 20dB under any condition of modulation.
4. QP detector shall be applied if not specified.

BV 7Layers Communications Technology (Shenzhen) Co. Ltd

No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China
Page 14 of 23

Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected]
Report Version 1

Test Report No.: W7L-211129W002EM03
2.2.2 TEST INSTRUMENTS

Frequency range below1GHz

Equipment

Manufacturer Model No.

3m Semi-anechoic Chamber

ETS-LINDGREN 9m*6m*6m

Bilog Antenna

ETS-LINDGREN 3143B

MXE EMI Receiver KEYSIGHT

N9038A-544

Signal Pre-Amplifier EMSI

EMC 9135

E3 Test Software E3

V 9.160323

Serial No. EuroshieldpnCT0001143-1216 00161965 MY54450026 980249 N/A

Last Cal.
May. 19,20
Mar. 05,21 Apr. 22,21 Jun. 02,21 N/A

Frequency range above 1GHz

Equipment

Manufacturer Model No.

3m Semi-anechoic Chamber

ETS-LINDGREN 9m*6m*6m

Horn Antenna

ETS-LINDGREN 3117

MXE EMI Receiver KEYSIGHT

N9038A-544

Signal Pre-Amplifier EMSI

EMC 012645B

E3 Test Software E3

V 9.160323

Serial No. EuroshieldpnCT0001143-1216 00168728 MY54450026 980257 N/A

Last Cal.
May. 19,20
May. 19,20 Apr. 22,21 Jun. 03,21 N/A

NOTE: 1. The test was performed in 3m chamber. 2. The FCC Site Registration No. is 525120; The Designation No. is CN1171.

Next Cal. May. 18,23
Mar. 04,22 Apr. 21,22 Jun. 01,22 N/A
Next Cal.
May. 18,23
May. 18,23 Apr. 21,22 Jun. 02,22 N/A

BV 7Layers Communications Technology (Shenzhen) Co. Ltd

No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China
Page 15 of 23

Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected]
Report Version 1

Test Report No.: W7L-211129W002EM03
2.2.3 TEST PROCEDURE
<Frequency Range below 1GHz>
The basic test procedure was in accordance with ANSI C63.4:2014 (section 12).
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter semi-anechoic chamber room. The table was rotated 360 degrees to determine the position of the highest radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower.
c. The height of antenna is varied from 1 meter to 4 meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to find the maximum reading.
e. The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum hold mode when the test frequency is below 1GHz.
NOTE: 1. The resolution bandwidth of test receiver/spectrum analyzer is 120kHz for Quasi-peak detection
(QP) at frequency below 1GHz.
2. Emission level(dBuV/m)=Raw Value(dBuV) + Correction Factor(dB/m)
3. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) (if the raw value not contains the amplifier);
4. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) ­ Amplifier Gain(dB) (if the raw value contains the amplifier).
5. Margin value = Emission level ­ Limit value.

BV 7Layers Communications Technology (Shenzhen) Co. Ltd

No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China
Page 16 of 23

Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected]
Report Version 1

Test Report No.: W7L-211129W002EM03
<Frequency Range above 1GHz>
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter fully-anechoic chamber room. The table was rotated 360 degrees to determine the position of the highest radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower.
c. The height of antenna is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement. The bore sight should be used during the test above 1GHz.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to find the maximum reading.
e. The test-receiver system was set to peak and average detect function and specified bandwidth with maximum hold mode when the test frequency is above 1 GHz
NOTE:
1. The resolution bandwidth of test receiver/spectrum analyzer is 120kHz for Quasi-peak detection (QP) at frequency below 1GHz.
2. The resolution bandwidth is 1MHz and video bandwidth of test receiver/spectrum analyzer is 3MHz for Peak detection at frequency above 1GHz. The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and video bandwidth of test receiver/spectrum analyzer is 1Hz for Average detection (AV) at frequency above 1GHz.
3. For measurement of frequency above 1000 MHz, the EUT was set 3 meters away from the receiver antenna.
4. Emission level(dBuV/m)=Raw Value(dBuV) + Correction Factor(dB/m)
5. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) (if the raw value not contains the amplifier);
6. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) ­ Amplifier Gain(dB) (if the raw value contains the amplifier)
7. Margin value = Emission level ­ Limit value.
2.2.4 DEVIATION FROM TEST STANDARD
No deviation.

BV 7Layers Communications Technology (Shenzhen) Co. Ltd

No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China
Page 17 of 23

Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected]
Report Version 1

Test Report No.: W7L-211129W002EM03

2.2.5 TEST SETUP
<Frequency Range below 1GHz>

EUT& Support Units
0.8m

3m Turn Table

Ant. Tower

Ground Plane Test Receiver

1-4m Variable

<Frequency Range above 1GHz>

EUT& Support Units
0.8m

Ant. Tower

Turn Table

3m Absorber

Ground Plane Test Receiver

1-4m* Variable
Bore Sight

Note: Above 1G is a directional antenna

Pre-amplifier

depends on the EUT height and the antenna 3dB bandwidth both, refer to section 7.3 of CISPR 16-2-3.

2.2.6 EUT OPERATING CONDITIONS

Same as item 2.1.6.

BV 7Layers Communications Technology (Shenzhen) Co. Ltd

No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China
Page 18 of 23

Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected]
Report Version 1

Test Report No.: W7L-211129W002EM03

2.2.7 TEST RESULTS

Worst case below 1G:

TEST VOLTAGE

Input 120 Vac, 60 Hz

ENVIRONMENTAL CONDITIONS

23deg. C, 70 %RH

TESTED BY

Jace Hu

FREQUENCY RANGE
DETECTOR FUNCTION & RESOLUTION BANDWIDTH

30-1000 MHz Quasi-Peak, 120 kHz

FREQ. (MHz)
80.44 167.74 313.24 422.85 625.58 703.18

ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M

EMISSION LEVEL
(dBuV/m)
21.32

READ LEVEL (dBuV)

LIMIT (dBuV/m)

MARGIN (dB)

50.27 40 -18.68

ANTENNA FACTOR (dB /m)
7.9

CABLE PREAMP

LOSS FACTOR

(dB)

(dB)

0.49 37.34

ANTENNA HEIGHT (cm)
200

TABLE ANGLE (Degree)
144

25.96 51.34 43.5 -17.54 10.63 0.69 36.7

200

324

22.01 43.46 46 -23.99 14.38 0.93 36.76

200

297

23.94 42.39 46 -22.06 17.31 1.11 36.87

200

309

23.47 38.28 46 -22.53 21.21 1.39 37.41

200

207

26.07 39.41 46 -19.93 22.72 1.48 37.54

200

54

REMARK
QP QP QP QP QP QP

REMARKS:

1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is measured corresponding to relevant limit and recorded in the data table.
2. Negative sign (-) in the margin column signify levels below the limit. 3. Frequency range scanned: 30MHz to 1000MHz. 4. Only emissions significantly above equipment noise floor are reported.

BV 7Layers Communications Technology (Shenzhen) Co. Ltd

No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China
Page 19 of 23

Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected]
Report Version 1

Test Report No.: W7L-211129W002EM03

TEST VOLTAGE
ENVIRONMENTAL CONDITIONS
TESTED BY

Input 120 Vac, 60 Hz 23deg. C, 70 %RH Jace Hu

FREQUENCY RANGE 30-1000 MHz

DETECTOR FUNCTION & RESOLUTION BANDWIDTH

Quasi-Peak, 120 kHz

FREQ. (MHz)
35.82 79.47 116.33 181.32 295.78 422.85

ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M

EMISSION LEVEL
(dBuV/m)
26.82

READ LEVEL (dBuV)

LIMIT (dBuV/m)

MARGIN (dB)

47.02 40 -13.18

ANTENNA FACTOR (dB /m)
17.05

CABLE PREAMP

LOSS FACTOR

(dB)

(dB)

0.34 37.59

ANTENNA HEIGHT (cm)
100

TABLE ANGLE (Degree)
188

30.94 59.51 40

-9.06

8.28 0.49 37.34

100

75

31.4 59.76 43.5 -12.1

8.16 0.57 37.09

100

221

28.28 53.82 43.5 -15.22 10.38 0.71 36.63

100

269

19.6 40.54 46

-26.4

14.9

0.9 36.74

100

86

22.84 40.97 46 -23.16 17.63 1.11 36.87

100

350

REMARK
QP QP QP QP QP QP

REMARKS:

1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is measured corresponding to relevant limit and recorded in the data table.
2. Negative sign (-) in the margin column signify levels below the limit. 3. Frequency range scanned: 30MHz to 1000MHz. 4. Only emissions significantly above equipment noise floor are reported.

BV 7Layers Communications Technology (Shenzhen) Co. Ltd

No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China
Page 20 of 23

Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected]
Report Version 1

Test Report No.: W7L-211129W002EM03
Worst case above 1G:

TEST VOLTAGE
ENVIRONMENTAL CONDITIONS TESTED BY

Input 120 Vac, 60 Hz 23deg. C, 70 %RH Jace Hu

FREQUENCY RANGE 1-18 GHz

DETECTOR FUNCTION

& RESOLUTION

Peak/Average, 1 MHz

BANDWIDTH

ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M

FREQ. (MHz)
1958

EMISSION LEVEL
(dBuV/m)
41.27

READ LEVEL (dBuV)

LIMIT (dBuV/m)

MARGIN (dB)

51.55 74 -32.73

ANTENNA FACTOR (dB /m)
30.29

CABLE PREAMP

LOSS FACTOR

(dB)

(dB)

5.27 45.84

ANTENNA HEIGHT (cm)
200

TABLE ANGLE (Degree)
257

REMARK
Peak

1958 26.02 36.3

54 -27.98 30.29 5.27 45.84

200

257 Average

3547 53.73 58.52 74 -20.27 33.03 7.28 45.1

200

234 Peak

3547 37.79 42.58 54 -16.21 33.03 7.28 45.1

200

234 Average

4969 49.66 51.52 74 -24.34 34.35 9.16 45.37

200

311 Peak

4969 34.76 36.62 54 -19.24 34.35 9.16 45.37

200

311 Average

REMARKS:

1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is measured corresponding to relevant limit and recorded in the data table.
2. Negative sign (-) in the margin column signify levels below the limit. 3. Frequency range scanned: 1GHz to 30GHz. For frequency above 18GHz, the emission
was tested 20db below the limit so the data not recorded in the sheet. 4. Only emissions significantly above equipment noise floor are reported.

BV 7Layers Communications Technology (Shenzhen) Co. Ltd

No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China
Page 21 of 23

Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected]
Report Version 1

Test Report No.: W7L-211129W002EM03

TEST VOLTAGE
ENVIRONMENTAL CONDITIONS
TESTED BY

Input 120 Vac, 60 Hz 23deg. C, 70 %RH Jace Hu

FREQUENCY RANGE 1-18 GHz

DETECTOR FUNCTION

& RESOLUTION

Peak/Average, 1 MHz

BANDWIDTH

ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M

FREQ. (MHz)
2158 2158 3668 3668

EMISSION LEVEL
(dBuV/m)
42.86 28.51 52.76 35.99

READ LEVEL (dBuV)

LIMIT (dBuV/m)

MARGIN (dB)

51.48 74 -31.14

37.13 54 -25.49

57.35 74 -21.24

40.58 54 -18.01

ANTENNA FACTOR (dB /m)
31.58 31.58
33 33

CABLE PREAMP

LOSS FACTOR

(dB)

(dB)

5.55 45.75

5.55 45.75

7.5 45.09

7.5 45.09

ANTENNA HEIGHT (cm)
100 100 100 100

TABLE ANGLE (Degree)
338 338 191 191

REMARK
Peak Average
Peak Average

4682 48.85 51.27 74 -25.15 34.09 8.77 45.28

100

183 Peak

4682 36.13 38.55 54 -17.87 34.09 8.77 45.28

100

183 Average

REMARKS:

1. Peak detector quick scan is showed on the graph and final quasi-peak detector data is measured corresponding to relevant limit and recorded in the data table.
2. Negative sign (-) in the margin column signify levels below the limit. 3. Frequency range scanned: 1GHz to 30GHz. For frequency above 18GHz, the emission
was tested 20db below the limit so the data not recorded in the sheet. 4. Only emissions significantly above equipment noise floor are reported.

BV 7Layers Communications Technology (Shenzhen) Co. Ltd

No.B102, Dazu Chuangxin Mansion, North of Beihuan Avenue, North Area, Hi-Tech Industrial Park, Nanshan District, Shenzhen51800, China
Page 22 of 23

Tel: +86 755 8869 6566 Fax: +86 755 8869 6577 Email: [email protected]
Report Version 1

Test Report No.: W7L-211129W002EM03
3 APPENDIX A ­ MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT BY THE LAB
No any modifications were made to the EUT by the lab during the test.