tclsevers

RFexposure

Dongguan Boxinda Electronic Technology Co., LTD B-19 4 in1 Wireless Charger 2A4OE-B-19 2A4OEB19 b 19

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 18 Pages, 5.28MB

Document DEVICE REPORTGetApplicationAttachment.html?id=6553182
Page 1 of 18

FCC ID: 2A4OE-B-19

RF Exposure Evaluation Report

1. Product Information
FCC ID: Number of tested samples Sample number Product Name Model Number
Power Supply
Modulation Type Frequency Range Antenna Type Hardware version Software version Accessories Exposure category EUT Type Device Type

2A4OE-B-19 2 A050423093-1(Engineer sample), A050423093-2(Normal sample) 4 in1 Wireless Charger B-19 Input: 9V 3A, 12V 3A Mobile phone output1: 15W Max Mobile phone output2: 10W Headphone port output: 3W Watch Output: 2W Continuous Wave 110.3~205.0KHz Coil Antenna / / / General population/uncontrolled environment Production Unit Mobile Device

Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 2 of 18

FCC ID: 2A4OE-B-19

2. Evaluation Method
Per KDB 680106 D01 Section 3. RF Exposure Requirements; 1) Consumer wireless power transfer devices approved under Part 15 in some cases have to
demonstrate compliance with RF exposure requirements. The potential for exposure must be assessed according to the operating configurations of the wireless system and the exposure conditions of users and bystanders. RF exposure must be evaluated with the client device(s) being charged by the primary at maximum output power. The RF exposure requirements must be determined in conjunction with the device operating characteristics, according to the mobile and portable exposure requirements in Section 2.1091 and Section 2.1093 of the rules. SAR and MPE limits do not cover the frequency range for wireless power transfer applications which operate below 100 kHz and 300 kHz respectively; therefore, RF exposure compliance needs to be determined with respect to 1.1307 (c) and (d) of the FCC rules. 2) Based on the design and implementation of the power transfer application, it must be clearly identified if mobile or portable RF exposure conditions apply. Devices that are installed to provide separation of at least 20 cm from users and bystanders may qualify for mobile exposure conditions. For some conditions where users and bystanders may be exposed at closer than 20 cm, section 2.1091(d) (4) of the rules may apply. 3) For devices designed for typical desktop applications, such a wireless charging pads, RF exposure evaluation should be conducted assuming a user separation distance of 15 cm. E and H field strength measurements or numerical modeling may be used to demonstrate compliance. Measurements should be made from all sides and the top of the primary/client pair, with the 15 cm measured from the center of the probe(s) to the edge of the device. Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 614 V/m and 1.63 A/m. A KDB inquiry is required to determine the applicable exposure limits below 100 kHz. 4) Portable exposure conditions from 100 kHz to 6 GHz are determined with respect to SAR requirements. Existing SAR systems and test procedures are generally intended for measurements above 100 MHz. While numerical modeling can be an alternative, the constraints of substantial computational resources at low frequencies could introduce further limitations. Under these circumstances, including operations below 100 kHz, the Commission may consider a combination of analytical analysis, field strength, radiated and conducted power measurements, in conjunction with some limited numerical modeling to assess compliance. 5) Depending on the operating frequency, existing SAR and MPE measurement procedures may be adapted to evaluate wireless power transfer devices for compliance with respect to mobile or portable exposure conditions. If the grantee or its test lab have any questions regarding RF exposure evaluation they should contact the FCC Laboratory with sufficient system operating configuration details to determine if RF exposure evaluation is necessary and, if required, how to apply specific test procedures. Below 100 MHz, when SAR testing is required and the device is operating at close proximity to persons, information on device design, implementation, operating configurations, exposure conditions of users and bystanders are needed to determine the evaluation and testing requirements. In addition, the influence of nearby objects may also need consideration according to the wireless power transfer system implementation; for example, the effects of placing the device, its coils or radiating elements on or near metallic surfaces
Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

3. Evaluation Limit

Page 3 of 18

FCC ID: 2A4OE-B-19

3.1 Refer evaluation method

ANSI C95.1­1999: IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz.
FCC KDB publication 680106 D01 RF Exposure Wireless Charging Apps v03: RF Exposure Considerations for Low Power Consumer Wireless Power Transfer Applications
FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits.
FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices

Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 4 of 18

FCC ID: 2A4OE-B-19

3.2 Limit

Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure

Frequency

Electric Field

Magnetic Field Power Density

Range(MHz)

Strength(V/m)

Strength(A/m)

(mW/cm²)

Limits for Occupational/Controlled Exposure

0.3-3.0 3.0-30

614 1842/f

1.63 4.89/f

*100 *900/f2

30-300

61.4

0.163

1.0

300-1,500

/

/

f/300

1,500-100,000

/

/

5

Averaging Time (minute)
6 6 6 6 6

Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure

Frequency

Electric Field

Magnetic Field Power Density

Range(MHz)

Strength(V/m)

Strength(A/m)

(mW/cm²)

Limits for General Population/Uncontrolled Exposure

0.3-1.34

614

1.63

*100

1.34-30

824/f

2.19/f

*180/f2

30-300

27.5

0.073

0.2

300-1,500

/

/

f/1500

1,500-100,000

/

/

1.0

Averaging Time (minute)
30 30 30 30 30

F=frequency in MHz *=Plane-wave equivalent power density

According to FCC KDB 680106 D01 Section 3. RF Exposure Requirements clause 3 the Emission-Limits in the frequency range from 100 KHz to 300 KHz should be assessed versus the limits at 300 KHz in Table 1 of CFR 47 ­ Section1.310 as following (measured distance shall be 15cm from the center of the probe to the edge of the device):

E-Field

*/*

B-Field

Frequency

V/m

A/m

uT

0.3 MHz ­ 3.0 MHz

614

1.613

2.0

3.0 MHz ­ 30 MHz

824/f (=27.530MHz)

2.19/f (=0.07330MHz)

--

A KDB inquire was required to determine/confirm the applicable limits below 100 KHz.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

4. Test Setup Diagram

Page 5 of 18

FCC ID: 2A4OE-B-19

5. Test Equipment

Equipment
Exposure Level Tester
B-Field Probe Electric field probe

Manufacturer Model

Serial no.

Narda
Narda Narda

ELT-400

N-0713

ELT-400

M-1154

EP601 611WX70332

Calibrated date
2022-10-29
2022-10-29 2023-01-29

Calibrated Due
2023-10-28 2023-10-28 2024-01-28

6. Measurement Uncertainty
95% confidence levels, k=2
Measurement Uncertainty

Magnetic field expanded uncertainty Elecric Field expanded uncertainty

= 3.65dB, k=2 = 2.67dB, k=2

7. Measurement Procedure
a) The RF exposure test was performed on 360 degree turn table in anechoic chamber. b) The measurement probe was placed at test distance (15cm and 20cm) which is between the edges of the charger and the geometric center of probe. c) The turn table was rotated 360d degree to search of highest strength. d) The highest emission level was recorded and compared with limit as soon as measurement of each points (A, B, C, D, E) were completed. e) The EUT were measured according to the dictates of KDB 680106D01v03.
Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 6 of 18

FCC ID: 2A4OE-B-19

8. Equipment Approval Considerations
The EUT does comply with item 5.2 of KDB 680106 D01v03 as follows table;

Requirements of KDB 680106 D01

Yes / No

Power transfer frequency is less than 1 MHz Yes

Output power from each primary coil is less than or equal to 15 watts

Yes

The system may consist of more than one

source primary coils, charging one or more

clients. If more than one primary coil is

Yes

present, the coil pairs may be powered on at

the same time.

Client device is placed directly in contact with the transmitter.

Yes

Mobile exposure conditions only (portable

exposure conditions are not covered by this Yes

exclusion).

The aggregate H-field strengths anywhere at

or beyond 15 cm surrounding the device,

and 20 cm away from the surface from all

coils that by design can simultaneously Yes
transmit, and while those coils are

simultaneously energized, are demonstrated

to be less than 50% of the applicable MPE

limit.

Description The device operate in the frequency range 110.3 KHz - 205 KHz Wireless charger output for iphone: The maximum output power of the primary coil is 15W. Charging systems have three primary coils and clients that are able to detect and allow coupling only between individual pairs of coils and the coil pairs powered on at the same time. Client device is placed directly in contact with the transmitter.
Mobile exposure conditions only
The EUT H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.

In all other cases, unless excluded above, an RF exposure evaluation report must be reviewed and accepted through a KDB or PBA inquiry to enable authorization of the equipment. When evaluation is required to show compliance; for example, using field strength, power density, SAR measurements or computational modeling etc., the specific authorization requirements will be determined based on the results of the RF exposure evaluation.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 7 of 18

FCC ID: 2A4OE-B-19

9. E and H field Strength
Test Modes Mode 1 AC/DC Adapter (12V/3A) + EUT + Phone1 (Battery Status: <1%) Mode 2 AC/DC Adapter (12V/3A) + EUT + Phone1 (Battery Status: <50%) Mode 3 AC/DC Adapter (12V/3A) + EUT + Phone1 (Battery Status: 100%) Mode 4 AC/DC Adapter (12V/3A) + EUT + Watch (Battery Status: <1%) Mode 5 AC/DC Adapter (12V/3A) + EUT + Watch (Battery Status: <50%) Mode 6 AC/DC Adapter (12V/3A) + EUT + Watch (Battery Status: 100%) Mode 7 AC/DC Adapter (12V/3A) + EUT + Phone2 (Battery Status: 100%) Mode 8 AC/DC Adapter (12V/3A) + EUT + Phone2 (Battery Status: 100%) Mode 9 AC/DC Adapter (12V/3A) + EUT + Phone2 (Battery Status: 100%) Mode 10 AC/DC Adapter (12V/3A) + EUT + Phone2 + Phone1 (Battery Status: <1%) Mode 11 AC/DC Adapter (12V/3A) + EUT + Phone2 + Phone1 (Battery Status: <50%) Mode 12 AC/DC Adapter (12V/3A) + EUT + Phone2 + Phone1 (Battery Status: 100%) Mode 13 AC/DC Adapter (12V/3A) + EUT + Phone1 + Watch + Phone2 (Battery Status: <1%) Mode 14 AC/DC Adapter (12V/3A) + EUT + Phone1 + Watch + Phone2 (Battery Status: <50%) Mode 15 AC/DC Adapter (12V/3A) + EUT + Phone1 + Watch + Phone2 (Battery Status: 100%)
Note: All test modes were pre-tested, but we only recorded the worst case in this report.

Record Record Record Record Record Record Record Record Record Record Record Record Record Record Record

Field Strength at 15 cm from the edges surrounding the EUT

Load mode

Frequency Range (kHz)

Field Strength

Measured E-Field Strength Values (V/m)

Measured H-Field Strength Values (A/m)

Test

Test

Test

Test

Position A Position B Position C Position D

Mode 1 110.3~205.0

uT

0.125

0.136

0.136

0.134

Mode 1 110.3~205.0 A/m

0.100

0.109

0.109

0.107

Mode 1 110.3~205.0 V/m

37.588

40.888

40.920

40.349

Mode 2 110.3~205.0

uT

0.122

0.134

0.137

0.131

Mode 2 110.3~205.0 A/m

0.098

0.107

0.109

0.104

Mode 2 110.3~205.0 V/m

36.739

40.295

41.068

39.261

Mode 3 110.3~205.0

uT

0.123

0.132

0.140

0.127

Mode 3 110.3~205.0 A/m

0.098

0.105

0.112

0.102

Mode 3 110.3~205.0 V/m

36.884

39.578

42.230

38.231

50% Limits
-0.815 307.0
-0.815 307.0
-0.815 307.0

Limits
-1.63 614.0
-1.63 614.0
-1.63 614.0

Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 8 of 18

FCC ID: 2A4OE-B-19

Field Strength at 20cm from the surface coils

Charging Battery Level

Frequency Range (kHz)

Field Strength

Measured E-Field Strength Values (V/m)
Measured H-Field Strength Values (A/m) Test
Position E

Mode 1 110.3~205.0

uT

0.146

Mode 1 110.3~205.0

A/m

0.117

Mode 1 110.3~205.0

V/m

43.954

Mode 2 110.3~205.0

uT

0.141

Mode 2 110.3~205.0

A/m

0.113

Mode 2 110.3~205.0

V/m

42.458

Mode 3 110.3~205.0

uT

0.138

Mode 3 110.3~205.0

A/m

0.111

Mode 3 110.3~205.0

V/m

41.566

50% Limits
-0.815 307.0
-0.815 307.0
-0.815 307.0

Limits
-1.63 614.0
-1.63 614.0
-1.63 614.0

Field Strength at 15 cm from the edges surrounding the EUT

Load mode

Frequency Range (kHz)

Field Strength

Measured E-Field Strength Values (V/m)

Measured H-Field Strength Values (A/m)

Test

Test

Test

Test

Position A Position B Position C Position D

Mode 4 110.3~205.0

uT

0.129

0.140

0.144

0.134

Mode 4 110.3~205.0 A/m

0.104

0.112

0.115

0.107

Mode 4 110.3~205.0 V/m

38.924

42.007

43.233

40.247

Mode 5 110.3~205.0

uT

0.127

0.140

0.135

0.132

Mode 5 110.3~205.0 A/m

0.102

0.112

0.108

0.106

Mode 5 110.3~205.0 V/m

38.182

42.007

40.716

39.714

Mode 6 110.3~205.0

uT

0.123

0.133

0.135

0.127

Mode 6 110.3~205.0 A/m

0.098

0.106

0.108

0.102

Mode 6 110.3~205.0 V/m

36.857

39.957

40.479

38.206

50% Limits
-0.815 307.0
-0.815 307.0
-0.815 307.0

Limits
-1.63 614.0
-1.63 614.0
-1.63 614.0

Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 9 of 18

FCC ID: 2A4OE-B-19

Field Strength at 20cm from the surface coils

Charging Battery Level

Frequency Range (kHz)

Field Strength

Measured E-Field Strength Values (V/m)
Measured H-Field Strength Values (A/m) Test
Position E

Mode 4 110.3~205.0

uT

0.135

Mode 4 110.3~205.0

A/m

0.108

Mode 4 110.3~205.0

V/m

40.458

Mode 5 110.3~205.0

uT

0.133

Mode 5 110.3~205.0

A/m

0.106

Mode 5 110.3~205.0

V/m

39.936

Mode 6 110.3~205.0

uT

0.127

Mode 6 110.3~205.0

A/m

0.101

Mode 6 110.3~205.0

V/m

38.044

50% Limits
-0.815 307.0
-0.815 307.0
-0.815 307.0

Limits
-1.63 614.0
-1.63 614.0
-1.63 614.0

Field Strength at 15 cm from the edges surrounding the EUT

Load mode

Frequency Range (kHz)

Field Strength

Measured E-Field Strength Values (V/m)

Measured H-Field Strength Values (A/m)

Test

Test

Test

Test

Position A Position B Position C Position D

Mode 7 110.3~205.0

uT

0.129

0.134

0.144

0.128

Mode 7 110.3~205.0 A/m

0.103

0.107

0.115

0.102

Mode 7 110.3~205.0 V/m

38.873

40.258

43.342

38.387

Mode 8 110.3~205.0

uT

0.127

0.130

0.137

0.126

Mode 8 110.3~205.0 A/m

0.101

0.104

0.110

0.101

Mode 8 110.3~205.0 V/m

38.063

39.199

41.167

38.022

Mode 9 110.3~205.0

uT

0.125

0.130

0.135

0.125

Mode 9 110.3~205.0 A/m

0.100

0.104

0.108

0.100

Mode 9 110.3~205.0 V/m

37.718

39.025

40.570

37.724

50% Limits
-0.815 307.0
-0.815 307.0
-0.815 307.0

Limits
-1.63 614.0
-1.63 614.0
-1.63 614.0

Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 10 of 18

FCC ID: 2A4OE-B-19

Field Strength at 20cm from the surface coils

Measured E-Field Strength Values

Charging Battery Level

Frequency Range (kHz)

Field Strength

(V/m) Measured H-Field Strength Values
(A/m) Test

Position E

Mode 7 110.3~205.0

uT

0.140

Mode 7 110.3~205.0

A/m

0.112

Mode 7 110.3~205.0

V/m

41.953

Mode 8 110.3~205.0

uT

0.136

Mode 8 110.3~205.0

A/m

0.109

Mode 8 110.3~205.0

V/m

40.858

Mode 9 110.3~205.0

uT

0.132

Mode 9 110.3~205.0

A/m

0.105

Mode 9 110.3~205.0

V/m

Note:V/m=10(((20lg(A/m*10^6)+51.5)-120)/20)

39.634

Note:A/m=uT/1.25

50% Limits
-0.815 307.0
-0.815 307.0
-0.815 307.0

Limits
-1.63 614.0
-1.63 614.0
-1.63 614.0

Field Strength at 15 cm from the edges surrounding the EUT

Load mode

Frequency Range (kHz)

Field Strength

Measured E-Field Strength Values (V/m)

Measured H-Field Strength Values (A/m)

Test

Test

Test

Test

Position A Position B Position C Position D

Mode 10 110.3~205.0

uT

0.130

0.140

0.144

0.131

Mode 10 110.3~205.0 A/m

0.104

0.112

0.115

0.105

Mode 10 110.3~205.0 V/m

39.049

41.969

43.393

39.535

Mode 11 110.3~205.0

uT

0.130

0.139

0.144

0.128

Mode 11 110.3~205.0 A/m

0.104

0.111

0.115

0.102

Mode 11 110.3~205.0 V/m

38.971

41.844

43.276

38.458

Mode 12 110.3~205.0

uT

0.119

0.134

0.141

0.125

Mode 12 110.3~205.0 A/m

0.096

0.108

0.113

0.100

Mode 12 110.3~205.0 V/m

35.897

40.413

42.440

37.502

50% Limits
-0.815 307.0
-0.815 307.0
-0.815 307.0

Limits
-1.63 614.0
-1.63 614.0
-1.63 614.0

Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 11 of 18

FCC ID: 2A4OE-B-19

Field Strength at 20cm from the surface coils

Measured E-Field Strength Values

Charging Battery Level

Frequency Range (kHz)

Field Strength

(V/m) Measured H-Field Strength Values
(A/m) Test

Position E

Mode 10 110.3~205.0

uT

0.124

Mode 10 110.3~205.0

A/m

0.099

Mode 10 110.3~205.0

V/m

37.258

Mode 11 110.3~205.0

uT

0.123

Mode 11 110.3~205.0

A/m

0.098

Mode 11 110.3~205.0

V/m

36.884

Mode 12 110.3~205.0

uT

0.120

Mode 12 110.3~205.0

A/m

0.096

Mode 12 110.3~205.0

V/m

Note:V/m=10(((20lg(A/m*10^6)+51.5)-120)/20)

36.012

Note:A/m=uT/1.25

50% Limits
-0.815 307.0
-0.815 307.0
-0.815 307.0

Limits
-1.63 614.0
-1.63 614.0
-1.63 614.0

Field Strength at 15 cm from the edges surrounding the EUT

Load mode

Frequency Range (kHz)

Field Strength

Measured E-Field Strength Values (V/m)

Measured H-Field Strength Values (A/m)

Test

Test

Test

Test

Position A Position B Position C Position D

Mode 13 110.3~205.0

uT

0.126

0.139

0.140

0.132

Mode 13 110.3~205.0 A/m

0.100

0.111

0.112

0.106

Mode 13 110.3~205.0 V/m

37.748

41.717

42.203

39.733

Mode 14 110.3~205.0

uT

0.125

0.135

0.140

0.132

Mode 14 110.3~205.0 A/m

0.100

0.108

0.112

0.106

Mode 14 110.3~205.0 V/m

37.555

40.712

41.978

39.710

Mode 15 110.3~205.0

uT

0.125

0.129

0.136

0.130

Mode 15 110.3~205.0 A/m

0.100

0.103

0.108

0.104

Mode 15 110.3~205.0 V/m

37.448

38.842

40.774

39.099

50% Limits
-0.815 307.0
-0.815 307.0
-0.815 307.0

Limits
-1.63 614.0
-1.63 614.0
-1.63 614.0

Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 12 of 18

FCC ID: 2A4OE-B-19

Field Strength at 20cm from the surface coils

Charging Battery Level

Frequency Range (kHz)

Field Strength

Mode 13 110.3~205.0

uT

Mode 13 110.3~205.0

A/m

Mode 13 110.3~205.0

V/m

Mode 14 110.3~205.0

uT

Mode 14 110.3~205.0

A/m

Mode 14 110.3~205.0

V/m

Mode 15 110.3~205.0

uT

Mode 15 110.3~205.0

A/m

Mode 15 110.3~205.0

V/m

Measured E-Field Strength Values (V/m)
Measured H-Field Strength Values (A/m) Test
Position E1 0.142 0.114 42.831 0.139 0.112 41.928 0.147 0.117 44.123

50% Limits
-0.815 307.0
-0.815 307.0
-0.815 307.0

Limits
-1.63 614.0
-1.63 614.0
-1.63 614.0

Charging Battery Level

Frequency Range (kHz)

Field Strength

Mode 13 110.3~205.0

uT

Mode 13 110.3~205.0

A/m

Mode 13 110.3~205.0

V/m

Mode 14 110.3~205.0

uT

Mode 14 110.3~205.0

A/m

Mode 14 110.3~205.0

V/m

Mode 15 110.3~205.0

uT

Mode 15 110.3~205.0

A/m

Mode 15 110.3~205.0

V/m

Measured E-Field Strength Values (V/m)
Measured H-Field Strength Values (A/m) Test
Position E2 0.145 0.116 43.449 0.147 0.117 44.124 0.139 0.111 41.786

50% Limits
-0.815 307.0
-0.815 307.0
-0.815 307.0

Limits
-1.63 614.0
-1.63 614.0
-1.63 614.0

Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 13 of 18

FCC ID: 2A4OE-B-19

Charging Battery Level

Frequency Range (kHz)

Field Strength

Mode 13 110.3~205.0

uT

Mode 13 110.3~205.0

A/m

Mode 13 110.3~205.0

V/m

Mode 14 110.3~205.0

uT

Mode 14 110.3~205.0

A/m

Mode 14 110.3~205.0

V/m

Mode 15 110.3~205.0

uT

Mode 15 110.3~205.0

A/m

Mode 15 110.3~205.0

V/m

Measured E-Field Strength Values (V/m)
Measured H-Field Strength Values (A/m) Test
Position E3 0.149 0.119 44.688 0.143 0.115 43.136 0.138 0.111 41.568

50% Limits
-0.815 307.0
-0.815 307.0
-0.815 307.0

20 cm above the top surface from all simultaneous transmitting coils

Measured E-Field Strength Values

Charging Battery Level

Frequency Range (kHz)

Field Strength

(V/m) Measured H-Field Strength Values
(A/m)

E1+E2+E3

Mode 13 110.3~205.0

uT

0.436

Mode 13 110.3~205.0

A/m

0.349

Mode 13 110.3~205.0

V/m

130.968

Mode 14 110.3~205.0

uT

0.429

Mode 14 110.3~205.0

A/m

0.344

Mode 14 110.3~205.0

V/m

129.188

Mode 15 110.3~205.0

uT

0.424

Mode 15 110.3~205.0

A/m

0.339

Mode 15 110.3~205.0

V/m

127.477

50% Limits
-0.815 307.0
-0.815 307.0
-0.815 307.0

Note:V/m=10(((20lg(A/m*10^6)+51.5)-120)/20) Note:A/m=uT/1.25

Limits
-1.63 614.0
-1.63 614.0
-1.63 614.0
Limits
-1.63 614.0
-1.63 614.0
-1.63 614.0

Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 14 of 18
10. Test Setup Photos
Test Position A - Exposure photo from side edge surface-Rear

FCC ID: 2A4OE-B-19

15cm

(Mode 13-Mode 15) Test Position B - Exposure photo from side edge surface-Left
15cm
Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 15 of 18 Test Position C - Exposure photo from side edge surface-Front

FCC ID: 2A4OE-B-19

15cm

Test Position D - Exposure photo from side edge surface-Right
15cm

Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 16 of 18 Test Position E - Exposure photo from top surface (20cm)

FCC ID: 2A4OE-B-19

20cm

E1
20cm
E2
Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 17 of 18

FCC ID: 2A4OE-B-19

20cm

E3

Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 18 of 18

FCC ID: 2A4OE-B-19

11. Conclusion
A minimum safety distance of at 15 cm surrounding the device and 20 cm above the top surface of the device is required when the device is charging a smart phone. The detected emissions with a distance of 15 cm surrounding the device and 20 cm above the top surface of the device are below the limitations according to FCC KDB 680106 D01 Section 3. RF Exposure Requirement Clause 3.

Report Version 000

Revision History

Issue Date May 15, 2023

Revision Content Initial Issue

Revised By --

.........................END OF REPORT.........................

Shenzhen LCS Compliance Testing Laboratory Ltd. Add:101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity



Related FCC IDs:

Search Any Device: