Catalogue international GB 2022
Décollage immédiat de Pyrocontrole avec Ariane | Chauvin Arnoux Metrix
Test and Measurement catalog
ASYC IV, Produits de l'Année 2016 par la revue Utility Products Magazine. | Chauvin Arnoux Metrix
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 224 Pages, 30.57MB
Document DEVICE REPORTcatalogue ca 2022-gb-bassdef vTEST& MEASURE2M022ENT chauvin-arnoux.com TITRE > CATÉGORIE > NOM PRODUIT 22 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com TITRE > CATÉGORIE > NOM PRODUIT THE CHAUVIN ARNOUX GROUP About the Chauvin Arnoux Group 4 UNIVERSAL TEST AND MEASUREMENT________________ 14 Testers 16 Voltage detectors 18 Analogue multimeters 21 Digital multimeters 23 Digital ammeters 28 Digital clamps 29 ELECTRICAL SAFETY____________________________ 34 Installation testers 39 Insulation testers 45 Multimeter clamps for leakage current 55 Earth and resistivity testers 56 Electrical equipment testers 63 Other testers 68 Data processing software 74 Accessories 76 ENERGY QUALITY & INSTALLATION MONITORING_________ 84 Power and harmonics clamps 86 Power and energy quality analysers 88 SOLAR POWER ANALYSERS_________________________ 93 Loggers 94 Data processing software 102 PHYSICAL & ENVIRONMENTAL MEASUREMENTS_________ 106 Calibrators 108 Thermal cameras 111 Thermometers 116 PH-meters 132 Conductimètre 133 Other physical and environmental measuring equipment 123 CURRENT MEASUREMENT________________________ 138 Current clamps AC 139 Current clamps AC/DC 141 Flexible sensors and probes 142 LABORATORY & EDUCATIONAL INSTRUMENTATION_______ 144 Training benches 146 Training cases 147 ACCESSORIES________________________________ 150 Cables & measurement probes with Ø4 banana connections 150 Accessories for Voltage Absence Testers or product-specific accessories 152 Other accessories 153 Protection, storage and transport 154 Fuses 156 METRIX____________________________________________________________ 158 Analogue testers & multimeters 160 On-site multimeters 164 Digital multimeters 170 Pocket clamp multimeters 174 On-site electrical safety tester 178 Benchtop oscilloscopes 181 Portable digital oscilloscopes 187 Spectrum analyser 198 Generators 200 Power supplies 206 Multifunction calibrators 208 Training cases and shunts 210 Accessories for oscilloscopes 211 Fuses 219 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 33 CHAUVIN ARNOUX GROUP > ABOUT THE CHAUVIN ARNOUX GROUP 128 YEARS OF DEVELOPMENT Logo on the company's former main gate Every story starts somewhere. The story of the Chauvin Arnoux company as an inventor and manufacturer of measuring instruments since 1893 is rich in developments and innovations. Today, its products bear witness to and reflect the sociological and technological changes and the industrial innovations which marked the previous century. A fascinating story that explains why and how Chauvin Arnoux's image and personality evolved... in two colours. It is often said that at the root of knowledge is language, or that the origin of an innovation was an idea,... yet it is the individual, the person, who is really the source of knowledge and discoveries. This also applies to electricity, which was not invented in the 19th century, but discovered in the 6th century BCE by a Greek philosopher and scientist named Thales, the first person to note the electrostatic properties of amber. From the beginning of the 19th century, there was the yellow of amber. Then manufactured goods began to include the yellow of brass and copper, materials used in measurement instruments, either for the casings of galvanometers or for the connections of electrical measurement instruments. Beige was also introduced with the use of varnished wood in the casings, while black was reserved for the instruments' dials. Right from the start in 1893, the contrast between black and the yellow of varnished wood soon became the norm for the measurement instruments produced by Chauvin Arnoux. In a relatively short time, between 1900 and 1936, with the development of new technologies and new techniques for working materials, yellow brass began to be used with black Bakelite, eventually spreading to nearly all our instruments. Already known for its sense of design and the combination of its original colours yellow brass and black, in its measurement instruments, Chauvin Arnoux reproduced these colours in its first corporate logo in 1927. In the 1940s, many measurement instruments only used black or black and the silver-grey of ferrous metals, sometimes painted. Chauvin Arnoux adapted its original visual identity to suit the fashions of the time, which also corresponded to technical criteria for safety, life-span extension or weight considerations linked to the metal and the manufacturing process used. The 1950s saw the arrival of rubber-like materials, used for the bases of portable instruments, and subsequently for the shockproof sheaths made of black neoprene, first designed and patented by Metrix® and Chauvin Arnoux in 1958. These shockproof sheaths later became widely used on the handheld instrument market. With the 1970s came plastics technology. This was when Chauvin Arnoux launched worldwide its first innovative products made of black and yellow plastic: the CDA 8 tester in 1979, the CDA 600 multimeter clamp in 1982, followed by the whole range. Some earth testers, such as the Terca in 1985 and the Prowatt wattmeters in 1989, also had a yellow casing.. The combination of yellow and black for on-site equipment began to spread with its use for safety signage and for identifying hazardous areas on site. This encouraged Chauvin Arnoux to launch the wellknown IMEG 500 or ISOL1000 series in Europe and then in the United States with the company's two colours. The MAN'X 500 series launched by Chauvin Arnoux, the very first multimeters made of a flexible material, further strengthened the company's visual identity. At about the same time, Metrix launched several products with yellow casings and black platens, including the instruments in its MX 44 series (1988) followed by the MX 51 series. Over the years, Chauvin Arnoux has developed its visual identity across all its product ranges: its multimeters, wattmeters, megohmmeters and installation testers all bear the company's colours. One last remark about colours: while yellow is always seen as the colour of the sun and of certain kings or emperors in Asia, it is not so widely known that in physics, black is the symbol of a "black body", meaning a system which absorbs all the light it receives. Black and yellow? A historic tandem for Chauvin Arnoux which was the first company to use this pairing for its corporate visual identity in the early 20th century when it first designed its logo in 1927. Axel Arnoux 1895 reflection galvanometer This calibration potentiometer dating from 1900 was used with a standard battery and a galvanometer like the one shown above. Its price was 195 francs! The Monoc L CDA 600 Polyclamp (1982) On both the French MICA multimeter in 1985 and the ANAGRAF American version available the same year, the yellow of Chauvin Arnoux is clearly in evidence. MX 51 42 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com CHAUVIN ARNOUX GROUP > ABOUT THE CHAUVIN ARNOUX GROUP MEASUREMENT EXPERTS The French electrical measurement specialist and international Group CHAUVIN ARNOUX relies on its Chauvin Arnoux® brand to propose a wide range of portable measuring instruments. Its offering covers the following sectors: · electrical measurement (testers, multimeters and current clamps) · electrical safety testing (insulation testers, ohmmeters, earth/ground testers) · recording and analysis of the power values (wattmeters and network quality analysers) · measurement of physical quantities (thermal cameras, luxmeters, sound level meters) A FEW FIGURES Laboratory and educational instruments (training benches and cases) complete the scope of its expertise. 1893-2022 Metering, control & supervision Portable test & measurement instrumentation Chauvin Arnoux®, Metrix® and Multimetrix® brands 6 expert measurement companies Metrology & regulatory testing 128 years in business 10 subsidiaries across the world 100 millions euros of sales revenues 1,000 employees 6 R&D departments worldwide 11% of revenues invested in R&D 8 production sites 3 in Normandy (France) 1 in Lyon (France) 1 in Montpellier (France) 1 in Milan (Italy) 1 in Dover (USA) 1 in Shanghai (China) Design of optical sensors for quality control in the laboratory and in-line processes Temperature sensors Expert in measuring agri-food product quality in real time by uorescence and infrared KNOW-HOW ACKNOWLEDGED IN ALL SECTORS OF ACTIVITY Electrical generation, transmission, distribution, installation & maintenance Tertiary and industrial maintenance, diagnostics & testing Improvement of energy efficiency R&D and laboratory work Education QUALITY, STANDARDS AND ECO-RESPONSIBLE APPROACH eco-design label for product development based on an eco-friendly approach The Group's ISO 9001 certification for the design processes and ISO 14001 certification for the manufacturing and sales processes demonstrate its determination to reconcile business and protection of the environment. In our laboratories, we carry out strict quality inspections and tests at each stage in the design and manufacturing processes: functional and metrological testing, mechanical and climatic testing, electromagnetic compatibility testing, electrical safety testing, ageing tests, etc. · Portable testers and multimeters · Current clamps & multimeter clamps · Insulation, earth and continuity testers · Installation and electrical equipment testers · Wattmeter-energy meters & electrical disturbance analysers · Thermal cameras, thermometers, tachometers, field meters, luxmeters, etc. · Loggers · Training benches TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 35 CHAUVIN ARNOUX GROUP > ALWAYS AT YOUR SERVICE > WWW.CHAUVIN-ARNOUX.COM PRINT & DIGITAL MEDIA FOR COMPLEMENTARY COMMUNICATION WHILE KEEPING IN CONTACT Whatever the device used, whether it is a smartphone, tablet or computer, Chauvin Arnoux offers users a website which guides them as they browse. It is simple to find, share and combine information, and offering more relevant information is an obvious target which the Group strives to achieve every day. A STRUCTURED WEBSITE Whatever the device used, whether it is a smartphone, tablet or computer, Chauvin Arnoux offers users a website which guides them as they browse. It is simple to find, share and combine information, and offering more relevant information is an obvious target which the Group strives to achieve every day. Chauvin Arnoux, Chauvin Arnoux Energy, Pyrocontrole, Indatech and Manumesure: each of these entities presents the full extent of its offering through its products, its skills, its applications and its publications, backed by a common visual identity giving a structured image of the Group. ONLINE SALES The Group proposes online sales of its main products. With just a few clicks, you can order the products and accessories you need, which then be delivered directly to you or to a pick-up location. METROLOGY & REGULATORY ENVIRONMENTAL TESTING Electrical, climatic, dimensional, force, weighing... Let us calibrate your measuring instruments! · 12 agencies all over France · Operations on site and in the laboratory · Maintenance, fleet management, repair, etc. CONTACT US [email protected] Tel.: + 33 231 64 51 35 Save time by using our online quotation request form www.manumesure.fr PRESENT ON SOCIAL MEDIA Follow all Chauvin Arnoux's news on the three main social media and our YouTube channel. Facebook www.facebook.com/ChauvinArnouxFrance Twitter twitter.com/ChauvinArnouxFr Linkedin www.linkedin.com/company/99353 Youtube www.youtube.com/c/chauvinarnouxgroup CHAUVIN ARNOUX, A LONG-TERM PARTNER FOR EDUCATION Drawing on its long history of close, privileged links with the French National Education system, the Chauvin Arnoux Group supports the players in education by participating in a large number of events, publishing the review "Les Cahiers de l'Instrumentation" and offering measuring instrumentation suited to the teaching requirements. A Measurement Certification and a dedicated website for students and teachers are also proposed to deal with the new constraints and to accompany tomorrow's professionals as closely as possible. THE "MEASUREMENT CLUB": A GENUINE FORUM FOR EXPERTISE! The "Club du Mesurage" (Measurement Club) is a genuine think-tank bringing together experts from business and educa- Les Cahiers N°18_Mise en page 1 30/11/2018 11:10 Page1 Cahiers Décembre 2018 Les n° 18 de l'instrumentation Le journal d'information pour l'enseignement de Chauvin Arnoux et Metrix L'ÉVOLUTION DE LA MESURE ÉLECTRIQUE tion in order to generate a constant flow of informa- tion about the evolution of the standards, the new market requirements, ap- plications and particularly new applications... Open · La méthode d'identification paramétrique · Un mode « SMART » Véhicules électriques et bornes de charge TP : La nécessité des mesures dans un monde « Smart » · Une évolution du mesurage, quand les capteurs deviennent virtuels · TP : Capteurs logiciels · Concours général des métiers de l'automobile to all members of the Education sector, this Club allows genuine theoretical debate as well as creating a forum of expertise between two communities brought together by common objectives , leading every year to publication of Chauvin Arnoux's magazine for Education, "Les Cahiers de l'Instrumentation". "LES CAHIERS DE L'INSTRUMENTATION": THE MAGAZINE FOR EDUCATION The magazine "Les Cahiers de l'instrumentation" is a collection of practical exercises published annually for teachers and their students, providing concrete illustrations of solutions or the use of measuring, testing and energy control instruments. A PRODUCT OFFERING DEDICATED TO THE EDUCATION SECTOR The Chauvin Arnoux Group proposes a special dedicated offering for the world of education which is presented every year in the "Selection for Education" catalogue. PARTNER OF MANY EDUCATIONAL EVENTS Every year, the Chauvin Arnoux Group acts as a partner and sponsor for a large number of events linked to the educational sector, intended to promote technical and scientific education by measuring equipment loans, the participation of Chauvin Arnoux managers in the judging panels or the provision of prizes for competitions. MEASUREMENT CERTIFICATION DEDICATED TO STUDENTS AND TEACHERS To deal with the new constraints and to support tomorrow's professionals as closely as possible, CHAUVIN ARNOUX has set up a measurement certification programme, in cooperation with the French national education system. The aim of this certification N I I I I I I III is to confirm students' RTIFICATIO knowledge of the use of measuring instrumIeI MnEtSsU REI by means of an online CERTIFICATION MESURE multiple-choice ques- CERTIFICATION MESURE tionnaire. CERTIFICATION MESURE CE III I I I I I I BAC PRO BTS et un nouveau site web dédiés aux étudiants et enseignants ELEEC TFCA TMSEC MEI TISEC ELEC MS FED DÉCOUVREZ LE SITE CERTIFICATION MESURE http://certification-mesure.chauvin-arnoux.com Discover Measurement Certification: certification-mesure.chauvin-arnoux.com 62 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com CHAUVIN ARNOUX GROUP > TRAINING CHAUVIN ARNOUX, A CERTIFIED TRAINING ORGANIZATION SINCE 1993 The Chauvin Arnoux Group proposes six one-day training modules. Whether you need theoretical training or practical experience based around a product, choose the market leader to train you and your staff. A training course dedicated to energy auditing has been set up specially to help you perform the right measurements. ENERGY AUDITS: CHOOSE THE RIGHT MEASUREMENTS · The advantages of energy auditing · Economical, environmental and regulatory constraints · People authorized to perform an energy audit · Towards a continuous improvement process: the ISO 50001 standard · Choosing the right measuring tool · Defining the potential sources of energy savings and the related measurements · Implementing appropriate solutions UNDERSTANDING AND OVERCOMING HARMONICS · The basics of harmonic phenomena. · Identifying and characterizing the sources of disturbances. · Measuring and detecting the phenomena in experimental conditions using a harmonic analyser. · The applicable standards and labels. · Understanding the effect of harmonics on the electrical components using real cases. · How to deal with harmonic disturbances. THERMOGRAPHY ·Understanding heat exchange phenomena. · Measuring with an infrared thermographic camera. · Interpreting the measurements. · Overview of all the applications of thermography and the present obligations. ELECTRICAL INSTALLATIONS AND ENERGY QUALITY ·Excessive consumption of reactive energy leading to penalty payments. · Loss of service continuity at the first fault on an IT system. · Untimely tripping of the circuit-breakers protecting industrial electrical equipment. · Untimely tripping of RCDs. · Random fault on an electricity distribution system. ELECTRICAL INSTALLATIONS AND IEC 60364-6 · Properties and objectives of the earth/ground connection systems · Behaviour of the earth/ground connection systems with regard to harmonics · Insulation resistance measurement · Electrical continuity measurements on protective conductors · Resistance measurements on earth/ground electrodes · Residual Current Device (RCD) testing CA 8336 NETWORK ANALYSER · Setup and connections · Presentation of the various measurements and functions: waveforms, harmonics, transients, alarms, etc. · Recording and measurement campaigns · Analysis of the measurement results · Simulation exercise with the instrument on an electrical model Training courses provided at the Chauvin Arnoux Group's new headquarters in Asnières, at the gates of Paris. ·Expert training instructors acknowledged in their fields · Innovative demonstration equipment to understand and operate · Limited number of participants for high-quality discussions TRAINING IS AN ESSENTIAL ADVANTAGE IN ANYONE'S CAREER. ·Favouring skills development · Gaining access to the different levels of qualification · Obtaining authorizations Detailed training schedule and registration form available from www.chauvin-arnoux.com or by sending a simple request to [email protected] TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 37 CHAUVIN ARNOUX GROUP > APPLICATIONS > GENERATION, TRANSMISSION & DISTRIBUTION APPLICATIONS: GENERATION, TRANSMISSION & DISTRIBUTION EARTH/GROUND CONNECTION TESTING Soil resistivity and earth/ground measurement 1 CA 6470N 1 Measurements on pylons 2 CA 6474 On MV/HV lines 3 CA 6472 INSTALLATION MAINTENANCE AND TESTING Separation of installations, voltage absence testing, phase sequence testing 4 CA 773 Testing of circuit-breakers and equipotential bonds 5 CA 6240 - CA 6292 15 kV insulation testing 6 7 CA 6555 Current measurements MA4000D 82 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com CHAUVIN ARNOUX GROUP > APPLICATIONS > GENERATION, TRANSMISSION & DISTRIBUTION Diagnostics & testing Education Energy efficiency Transports Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology 2 3 3 5 6 4 5 9 7 8 Electrical consumption monitoring PEL106 ENERGY SURVEY Analysis of electrical network quality (flicker, over- and undercurrent/voltages/harmonics 8 9 CA 8336 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 39 CHAUVIN ARNOUX GROUP > APPLICATIONS > INDUSTRY APPLICATIONS: INDUSTRY DETECTION OF ELECTRICAL DISTURBANCES Power quality analysis 1 2 CA 8336 Recording of voltage drops and voltage surges L261 5 INDUSTRIAL MAINTENANCE Testing for electrical or mechanical overheating 3 CA 1954 REGULATORY TESTING OF THE WORKING ENVIRONMENT Noise 4 CA 1310 Lighting 5 CA 1110 Humidity 6 CA 1246 6 10 1 10 Electric fields 7 CA 40 102 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com 11 9 8 3 9 Electrical network CHAUVIN ARNOUX GROUP > APPLICATIONS > INDUSTRY Diagnostics & testing Education Energy efficiency Transports Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology Voltage absence testing 8 CA 762 IP2X Detection of leakage currents CA 5275 + B102 SAFETY OF PEOPLE 9 Earth/ground testing 10 CA 6417 4 13 12 2 12 7 Industrial machine testing 13 CA 6165 Insulation testing 11 CA 6524 MANUFACTURING QUALITY CONTROL Electrical cabinet testing 12 CA 6155 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 311 CHAUVIN ARNOUX GROUP > APPLICATIONS > HOUSING & TERTIARY APPLICATIONS: HOUSING & TERTIARY REGULATORY TESTING AS PER IEC 60364-6 Earth/continuity measurement 1 CA 6462 Comprehensive electrical safety testing on installations 2 CA 6116N 4 ENERGY EFFICIENCY Measurement of insulation, leakproofing and thermal bridges 3 CA 1954 Temperature, air speed and air flow-rate measurement 4 CA 1227 CO2 temperature and humidity testing 5 CA 1510 3 8 6 Recording and analysis of electrical consumption 6 PEL104 4 4 10 5 6 9 7 1 0% 62% 100% 122 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com CHAUVIN ARNOUX GROUP > APPLICATIONS > HOUSING & TERTIARY Diagnostics & testing Education Energy efficiency Transports Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology 3 97 2 5 8 GENERAL ELECTRICAL RENOVATION WORK Testing of the power supply and continuity of electrical connections 7 CA 755 Detection and location of cables and metal 2 conductors 8 CA 6681 Verification of voltages, currents and electrical continuity 2 9 F201 10 Ionization current measurement on gas boilers 10 CA 5277 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 313 UNIVERSAL TEST & MEASUREMENT > INFO AND ADVICE > THE STANDARDS THE STANDARDS 14 DIGITAL MULTIMETERS 23 TESTERS 16 DIGITAL AMMETERS 32 VOLTAGE ABSENCE TESTERS 18 DIGITAL CLAMP METERS 29 ANALOGUE MULTIMETERS 21 ACCESSORIES 32 THE STANDARDS EN 60529 The EN 60529 standard defines the level of tightness (leakproofing) of an instrument against penetration by solids or water. The IP rating corresponds to the instrument's level of protection against penetration by solids (1st digit) and by water (2nd digit). The higher the rating, the more effective the protection. A product without protection corresponds to a rating of IP00 (minimum rating), whereas a product totally protected against penetration by solids and liquids would have a rating of IP68 (maximum rating). IEC 61010 This international standard defines the safety rules for electrical measuring, control and laboratory instruments. It helps to ensure that the design and construction of the instruments protect users and their environment against electric shocks, burns, mechanical hazards, the spread of fire from these instruments, excessive temperatures, etc. For some types of instrument, this standard is completed by specific instructions. The development of industrial and domestic equipment is increasing the hazards which may be encountered on an electrical installation, notably in terms of ever-higher voltage surges. On LV installations, where the voltages are limited to 1,000 VAC and 1,500 VDC, the hazard levels depend the type of installation and the voltage level. Les normes internationales de la famille CEI 61010 concernent les règles de sécurité pour appareils électriques dThe international standards in the IEC 61010 family concern the safety rules for electrical measuring, control and laboratory instruments and their uses. More specifically, the IEC 61010-031 standard and its amendment A1 which define the safety rules for measuring instruments and accessories used with them. In the new edition which came into force on 1st March 2011, this standard has been completed with Chapter 13 covering "prevention of hazards linked to short-circuits and electric arcs". This addition stipulates the following rules for work on CAT III and CAT IV installations: The conductive part of test probes must not exceed 4 mm in length The external surfaces of the jaws of crocodile clips must be non-conductive and the conductive parts must not be accessible when the clip is closed. The IEC 61010-2-033 standard, first published on 09/02/2013, has brought changes concerning multimeters, clamp multimeters, etc. Since 9th March 2015, these instruments have had to guarantee a minimum safety level corresponding at least to CAT III 300 V. SAFETY RULES AND GOOD PRACTICES Use measuring instruments and accessories which are suitable for the application and the measuring conditions. Prefer CAT IV instruments: · They can withstand voltage surges which are up to 50 % greater than a CAT III product · CAT IV 1000 V provides protection against electric shocks up to 12,000 V, while CAT IV 600 V instruments protect up to 8,000 V. · Using a lower-category instrument means checking that the installation is equipped with protective systems (disconnecting switch, circuitbreaker, etc.) which are functional and in good condition. This is often the case... but not always! · For outdoor or temporary installations or for installations upstream of the protective systems, CAT IV instruments must be used. It is the weakest element which defines your level of protection. If you use accessories of a lower category or with a lower voltage than your measuring instrument, the global level of safety offered by your measuring system will be reduced. Use accessories in perfect condition. Any accessory which is faulty, however slightly, must be replaced immediately as it can no longer guarantee your safety. The fuses are protective elements. If you replace them with cheaper models or, even worse, with a metal element (copper wire, aluminium foil, etc.), you will no longer be protected against possible voltage surges on your installation. CCCAAATTT IIIIII CCAAATTTIIIIIIIII CCAAATTTIIIVVV CAT II: Measurements on circuits connected directly to the low-voltage installation. Examples: domestic distribution system, portable or domestic appliances and equipment, mains power sockets. CAT III: Measurements on the building's installation. Examples: fixed installations involved in industrial distribution and the input circuits for electrical maintenance of a building (lighting, lift, etc.). CAT IV: Measurements at the source of the lowvoltage installation. Examples: direct distribution circuit, primary sources, overhead-line and cable systems, including distribution busbars and the associated protective equipment against voltage surges. 142 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com UNIVERSAL TEST & MEASUREMENT > INFO AND ADVICE > TECHNICAL REMINDERS UNIVERSAL TEST & MEASUREMENT TECHNICAL REMINDERS NUMBER OF COUNTS (FOR MEASUREMENT) This is one of the fundamental specifications of instruments using analogue-digital conversion. It is usually used to define the measurement range and the resolution, on the basis of the value chosen as the rated calibre. MEASUREMENT RANGE This indicates the limits within which a digital instrument maintains its specified characteristics. The measurements obtained are not subject to an error greater than the maximum tolerated error. It is defined by a minimum measurable value and a maximum measurable value. RATED CALIBRE The calibre of an instrument is the value of the quantity to be measured which corresponds to the upper limit of the measurement range. For example, for an ammeter, if this upper limit is 5 A, its calibre is said to be 5 A. RESOLUTION This is the smallest measurable value difference. It is also the value of one measurement count or unit of quantification which is usually termed the "unit". MINIMUM MEASURABLE VALUE (OR THRESHOLD) This is the smallest measurable value. For an instrument with excellent conversion linearity, it may be the same as the resolution. This is not always the case and the manufacturer should indicate it clearly, because this minimum value also depends on the accuracy, and particularly on the constant error. When the constant error is too high, it becomes impossible to obtain valid measurements of very low values. RMS: ROOT MEAN SQUARE The term RMS (Root Mean Square) refers to the effective value. By definition, the effective value of any current is the value of the DC current which would produce the same heating when flowing through a resistor Vrms The amplitude (Vc) of a voltage or of a sinusoidal current is equal to 2 times its RMS value (Vc = 2 VRMS). It is crucial to know this RMS value in industrial environments; it is this value which is used to define a current. Vpeak V Thus, for the 230 V/ 50 Hz RMS mains network: VRMS = 230 V Vpeak = 325 V V = 207 V avg For a sinusoidal VRMS A voltage: V avg Vpeak = VRMS x 2 Vavg = 0.9 VRMS An "average value" measuring instrument measures the average value of a sinusoidal current, after rectification and filtering, and displays the RMS value after applying a coefficient of 1/0.9 = 1.111 This indirect measurement method is simple and accurate but only valid for an undistorted sinusoidal current. It only tolerates distortion of a few percent. This is why "RMS" measuring instruments are increasingly widely used. They rely on direct measurement principles: the thermal method (used mainly in metrology) and analogue or digital calculation methods requiring sophisticated electronic components. PEAK VALUE CREST FACTOR The crest factor is expressed as follows CF = Vpeak / Vrms This information complements the RMS value, allowing you to assess the distortion of a signal in qualitative terms. For a sinusoidal signal, CF = 2 = 1.414 In the specific case of a sinusoidal quantity, application of the relation above gives: V = Vpeak cos wt Vrms peak Vpeak ADVICE When we speak of a 230 V network voltage, we are referring to an RMS value. For many years, the level of distortion caused by linear loads (incandescent lamps, heating) connected to the network was very low. The spread of non-linear loads (switching power supplies, light dimmers, variable speed-drives or compact fluorescent lamps) is calling this approach into question, as "pure" sinusoidal currents are becoming increasingly rare on the network. Conventional measuring instruments (calculating the RMS value from the average value) are only accurate with sinusoidal currents, as a matter of principle. Otherwise, the measurement error may be as high as 50 %! You are advised to opt for "RMS" measuring instruments which are capable of providing correct measurements, whatever the waveform of the current or voltage. TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 315 UNIVERSAL TEST & MEASUREMENT > TESTERS > SELECTION GUIDE | CA 732 CHOOSE YOUR TESTER Strengths Display Single-pole phase detection No-contact phase detection AC or DC voltage detection Audible continuity Resistance Diode Capacitance Current Removable test probe 600V CAT III 1000V CAT III CA 732 page 16 Built-in torch Moulded body for exceptional handling LEDs CA 745N page 17 Phase test with a single test probe Continuity and resistance test LCD bargraph CA 755 page 17 Casing with built-in compartment for stowing the test probes Measurements up to 1,000 V Backlit digital display CA 757 page 17 MiniFlex® measurement accessory supplied Measurements up to 1,000 V Backlit digital display CA 732 REF. : P01191745Z 1000 V CAT III STRENGTHS · No contact phase detection · Built-in torch · Moulded body for exceptionally comfortable handling Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology SPECIFICATIONS Detection threshold Audible beep Operating frequency Standards Power supply Dimensions / weight CA 732 195 Vac U 265 Vac U > 230 V 50/60 Hz IEC 61010 1000 V CAT III 2 x 1.5 V LR03 batteries 176 x 26 mm / 48 g CONTENTS CA 732 delivered in blister pack with 2 x 1.5 V LR03 batteries ACCESSORIES / REPLACEMENT PARTS 1.5 V LR03 battery P01296032 162 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com UNIVERSAL TEST & MEASUREMENT > TESTERS > CA 745N | CA 755 - CA 757 CA 745N REF. : P01191743Z 600 V IP CAT III 54 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology CA 755 - CA 757 54 REF. : P01191755 REF. : P01191757 600 V IP CAT III Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Measurements up to 1,000 V · Backlit digital display · Built-in compartment for stowing test probes in casing · CA 757: MiniFlex® current measurement accessory supplied STRENGTHS · No risk of tripping high-sensitivity RCDs during phase/earth testing SPECIFICATIONS Voltage test Audible beep Impedance Phase/neutral identification Operating frequency Polarity test Voltage protection Audible continuity test Resistance test Standards Power supply Dimensions / weight CA 745N 12 V to 690 V~ (7 segments) U > 50 V~ 400 k Flashing "Ph" diode and intermittent audible beep for U > 100 V~ DC and 50/60 Hz "+" and "-" symboles Up to 1,100 V R < 2 k 2 k to 300 k (3 segments) IEC 61010 600 V CAT III 2 x 1.5 V LR03 batteries 180 x 52 x 45 mm / 200 g CONTENTS CA 745N delivered in a blister pack with 2 x 1.5 V LR03 batteries, 2 removable test probes (red/black) ACCESSORIES / REPLACEMENT PARTS 1.5 V LR03 battery 1 set of CAT III/IV test probes (red/black) Set of red/black test probes, Ø 2 mm, CAT II Set of red/black test probes, Ø 4 mm, CAT II CA 753 universal measuring adapter for 2P+E sockets Velcro strap x 5 Bag compatible with MultiFix accessory, 120 x 200 x 60 mm MultiFix mounting accessory P01296032 P01102152Z P01102153Z P01102154Z P01191748Z P01102113 P01298074 P01102100Z SPECIFICATIONS Current test Measurement range via current sensor Resolution DC voltage Measurement range Resolution AC voltage Measurement range Resolution Operating frequency Impedance No-contact voltage detection Audible continuity test Resistance test Measurement range Resolution Capacitance test Measurement range Resolution Standards Power supply Battery life Dimensions / weight CA 755 CA 757 500 mA to 300 A (2 calibres) 0.01 A to 0.1 A 3 mV to 1,000 V 4 calibres 1 mV to 1 V 100 mV to 1,000 V 4 calibres 1 mV to 1 V DC and 50/60 Hz 10 M 230 V 50/60 Hz at a distance of approx. 5 cm R 30 0,3 to 30 M 6 calibres 0.1 to 0.01 M 400 pF to 30 mF 0.001 nF to 0.01 mF 600 V CAT III, IEC 61010-1, IEC 61010-031, IEC 61010-032, IEC 61010-033 2 x 1.5 V LR03 batteries 100 hours with alkaline batteries Automatic standby after 10 minutes 180 x 52 x 45 mm / 200 g CONTENTS ·C A 755 delivered with 1 set of extra-fine test probes CAT III/CAT IV (red/black), 2 x 1.5 V LR3 alkaline batteries · CA 757 delivered with 1 set of extra-fine test probes CAT III/CAT IV (red/ black), 2 x 1.5 V LR3 alkaline batteries, 1 MiniFlex® sensor with a loop length of 250 mm, a connection cable 1 m long and a specific connector for CA 757, 1 Velcro strap ACCESSORIES / REPLACEMENT PARTS 1 set of test probes (red/black) CAT III / IV 1.5 V LR03 battery See all the accessories on page 32 P01102152Z P01296032 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 317 UNIVERSAL TEST & MEASUREMENT > VOLTAGE DETECTORS / VOLTAGE ABSENCE TESTERS > SELECTION GUIDE CHOOSE YOUR VOLTAGE DETECTOR / VOLTAGE ABSENCE TESTER CA 742 / IP2X page 19 600V CAT IV 1000V CAT IV IP2X version Single-pole phase detection AC or DC voltage test Stray voltage detection RCD tripping Audible continuity Extended continuity / resistance "2-wire" phase rotation Removable test probe Compliant with IEC 61243-3 Built-in self-test LED display Digital display Extended climatic class IP65 CA 762 / IP2X page 19 CA 771 / IP2X page 20 CA 773 / IP2X page 20 182 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com UNIVERSAL TEST & MEASUREMENT > VOLTAGE DETECTORS > CA 742 - CA 742 IP2X | CA 762 - CA 762 IP2X CA 742 - CA 742 IP2X | CA 762 - CA 762 IP2X 65 REF. : P01191742Z REF. : P01191742D REF. : P01191762Z REF. : P01191762D 600 V IP IEC NF C CAT IV 61243-3 18-510 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Full integrated Autotest · Voltage test up to 690 Vac (16 2/3 800 Hz) / 750 Vdc · IP2X versions available, compliant with NF C 18-510 · Removable test probe and lead · Phase-sequence testing up to 400 Hz SPECIFICATIONS CA 742 CA 762 Voltage detection Voltage 12 Vac U 690 Vac 12 Vdc U 750 Vdc Frequency DC, 16 2/3 to 800 Hz Impedance > 300 k > 400 k Max. current Polarity indication 3.5 mA RMS Yes Hazardous voltage indication The red ELV (Extra Low Voltage) LED indicates when the voltage is higher than the SELV (Safety Extra Low Voltage); the higher the voltage, the faster it flashes. Phase / Neutral identification Above 120* V (45 - 65 Hz) Above 400 V (16 2/3 - 45 Hz) Continuity with buzzer Trigger threshold 100 typical (150 max.) Extended continuity test - 2 k, 60 k, 300 k Test current 1 mA Open-circuit voltage 3.3 V Protection Up to 1,000 V Phase rotation No 2-wire method Ph/Ph voltage - 50 V U 690 Vac Frequency - Between 45 and 400 Hz Buzzer Intermittent beep for voltage detection and continuous beep for continuity Standards and electrical safety IEC 61010 600 V CAT IV IEC 61243-3 Ed.2 concerning Voltage Detectors IEC 61326-1, emissions and immunity in industrial environments Ingress protection of enclosure Casing: IP65 Test probes (option): IP2X Climatic conditions Use from -15 °C to +45 °C / 20 to 95 % RH Power supply 2 x 1.5V (LR03) batteries Battery life 7,500 x 10 s measurements 7,000 x 10 s measurements Dimensions / weight 163 x 64 x 40 mm / 210 g * Typical value with standard individual protective equipment ADDITIONAL INFO · Don't forget the adapter for 2P+E sockets CA 751..................................... P01101997Z CONTENTS · 1 voltage detector delivered with: · 1 black Ø 2 mm test-probe lead with crystal safety cap · 1 red Ø 2 mm test-probe lead with crystal safety cap · 1 wrist-strap · 2 x 1.5 V LR03 batteries The IP2X version is delivered with: · 2 x Ø 4 mm IP2X test probes (red/black) · 1 black cable 1.10 m long equipped with a probe-holder system · 1 wrist strap · 2 x 1.5 V LR03 batteries ACCESSORIES / REPLACEMENT PARTS Red test probe Ø 2 mm Crystal safety cap for Ø 2 mm test probe (x10) See all the accessories on page 32 P01102008Z P01102033 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 319 UNIVERSAL TEST & MEASUREMENT > VOLTAGE DETECTORS / VOLTAGE ABSENCE TESTERS > CA 771 - CA 771 IP2X | CA 773 - CA 773 IP2X CA 771 - CA 771 IP2X | CA 773 - CA 773 IP2X REF. : P01191771 REF. : P01191771A REF. : P01191773 REF. : P01191773A 65 1000 V IP IEC NF C CAT IV 61243-3 18-510 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Full Autotest with indication of the type of fault · Lighting of the point of measurement · Automatic standby · Extended climatic class · IP2X version available, compliant with NF C 18-510 SPECIFICATIONS CA 771 CA 773 Display LEDs LEDs + Backlit digital display Voltage detection Voltage 12 Vac U 1000 Vac 12 Vdc U 1400 Vdc Frequency Impedance DC, 16 2/3 to 800 Hz > 500 k Max. current 3.5 mA RMS Indication of polarity Yes Stray voltage detection Yes (by low-impedance load switching) RCD tripping Yes (by low-impedance load switching Approx. 30 mA to 230 V Redundant hazardous voltage indication The ELV (Extra Low Voltage) LED indicates a voltage higher than the SELV (Safety Extra Low Voltage) with the flashing rate proportional to the voltage Phase / neutral identification Continuity & resistance Above 50 V (45 - 65 Hz) Above 150 V (162/3 - 45 Hz) Buzzer trigger threshold 100 typical (150 max.) 100 typical (150 max.) Extended continuity test (resistance) 2 k, 60 k, 300 k 0.5 to 2.999 k Test current / open-circuit voltage 1 mA / 3.3 V Phase rotation 2-wire method Ph/Ph voltage 50 V U 1000 Vac (45 - 400 Hz) Buzzer Intermittent beep for voltage detection / Continuous beep for continuity Standards and electrical safety IEC 61243-3:2009, EN 61243-3:2010 IEC 61010 1000 V CAT IV Enclosure ingress protection IP65 Climatic conditions -30 °C to +60 °C (extended "Class S") -15 °C to +45 °C ("Class N") Battery life > 5,000 x 10s measurements > 2,500 x 10s measurements Dimensions / weight 228 x 60 x 39 mm (without test probe) / 350 g approx. ADDITIONAL INFO · Don't forget the universal measurement adapter for testing your 2P+E power sockets CA 753..................................... P01191748Z CONTENTS · 1 voltage detector delivered with: · 1 set of red/black Ø 2 mm removable test probes with crystal safety cap · 1 test-probe protector · 1 Velcro strap · 2 x 1.5 V LR03 batteries The IP2X version is delivered with: · 1 set of red/black IP2X Ø 4 mm removable test probes with crystal safety cap · 1 Velcro strap · 2 x 1.5 V LR03 batteries ACCESSORIES / REPLACEMENT PARTS CA 753 measurement adapter for 2P+E socket Bag See all the accessories on page 32 P01191748Z P01298076 202 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com UNIVERSAL TEST & MEASUREMENT > ANALOGUE MULTIMETERS > SELECTION GUIDE CHOOSE YOUR ANALOGUE MULTIMETER CA 5001 page 22 Analogue Digital Anti-parallax mirror 4,000-count display Backlighting TRMS AC + DC measurement method Max. Low-impedance calibre (LowZ) AC and DC current Current with clamp A calibre 5 A calibre 10 A calibre 15 A calibre Resistance Audible continuity Frequency dB Fuse status LED Voltage presence LED in ohmmeter mode CA 5003 page 22 CA 5005 page 22 CA 5011 page 22 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 321 UNIVERSAL TEST & MEASUREMENT > ANALOGUE MULTIMETERS > CA 5001 - CA 5003 - CA 5005 | CA 5011 CA 5001-CA 5003-CA 5005 REF. : P01196521E REF. : P01196522E REF. : P01196523E CA 5011 REF. : P01196311E Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology 600 V IP CAT III 53 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology 53 600 V CAT IV IP TRMS STRENGTHS · "Fus" LED: HRC fuse check · VoltestTM" LED: voltage presence in ohmmeter* mode · Automatic tare in ohmmeter mode* ·A calibres · Compact, shockproof casing with multi-purpose "MultistandTM" articulated stand for CA 5003 and CA 5005 * for CA 5003 and CA 5005 SPECIFICATIONS DC voltage AC voltage Internal resistance Operating frequency DC current AC current Resistance Audible continuity test Scale in dB for Vac Typical accuracies(4) Power supply Battery life Electrical safety(5) Protection(6) Ingress protection Climatic conditions Dimensions / weight CA 5001 CA 5003(1) CA 5005(1) 8 calibres: 100 mV / ... / 1000 V(2) 5 calibres: 10 V / ... / 1000 V(2) 20 k/V 10 Hz ... 100 kHz depending on calibre 5 cal.: 7 cal.: 6 cal.: 50 A / ... / 5 A 50 µA / ... / 15 A 50 A / ... / 10 A 4 cal.: 5 cal.: 5 cal.: 5 mA / ... / 5 A 1.5 mA / ... / 15 A 3 A / ... / 300 A(3) 2 cal.: 10 k and 1 M R < 50 0 ... +22 dB 1.5% for Vdc · 2.5% for Vac and Aac · 10% for 1 x 1.5 V LR06 battery 1 x 9 V 6LR61 battery 10,000 x 15 s measurements 10,000 x 10 s measurements IEC 61010-1 Edition 2 600 V CAT III 0.5 A and 5 A HRC fuses 1.6 A and 16 A HRC fuses 1 A and 10 A HRC fuses IP 40 IP 53 -10 °C ... +55 °C and RH < 90 % 160 x 105 x 56mm / 500 g (1) Additional "VoltestTM" function to check for the possible presence of a voltage during resistance measurement and audible continuity test - (2) Use limited to 600 V max. (3) Limited to 240 A max. by the MN 89 miniclamp (4) In % of end-of-scale - (5) Degree of pollution 2 - (6) Electronic protection and HRC fuses for the current calibres with fuse test LED. ADDITIONAL INFO · Also delivered complete in a hard case: CA 5001 case..........P01196521F CA 5003 case..........P01196522F CA 5005 case..........P01196523F · The CA 5005 is delivered with a current clamp for measurements up to 200 AAC STRENGTHS ·Extra safety with 2 LEDs: "Fus": HRC fuse test, "VoltestTM": voltage presence in ohmmeter mode ·Two complementary readings: digital for accuracy, with backlighting, and analogue for quick reading ·Automatic AC/DC recognition ·Compact, shockproof casing with multi-purpose MultistandTM articulated stand SPECIFICATIONS CA 5011 DC and AC voltage 2 x 5 calibres: 400 mV / ... / 1000 V(1) Impedance Operating frequency(2) 10 M 20 Hz / ... / 10 kHz DC and AC current 2 x 6 calibres: 400 µA / ... / 10 A Resistance(3) Audible continuity test(3) 6 calibres: 400 / ... / 40 M R < 400 Frequency 3 calibres: 4 kHz / ... / 400 kHz Scale in dB for Vac -20 dB ... +16 dB Max. value Over 500 ms Typical accuracies(4) 1% for Vdc and , 1.5 % for Adc Power supply 1 x 9 V 6LR61 battery Battery life 300 hours Electrical safety(5) IEC 61010-1 Edition 2 600 V CAT IV Protection(6) 1 A and 10 A HRC fuses Ingress protection IP 53 Climatic conditions -10°C ... +55°C and RH < 90% Dimensions / weight 160 x 105 x 56mm / 500 g (1) Use limited to 600 V max. (2) Crest factor 5 (3) Additional VoltestTM function to check for the possible presence of a voltage - (4) In digital mode. In analogue mode: 2.5 % (5) Degree of pollution 2 (6) Electronic protection and HRC fuses for the current calibres with fuse test LED. ADDITIONAL INFO · Also available delivered complete in hard case: CA 5011 case........................... P01196311F CONTENTS · CA 5001 delivered with 1 set of silicone straight banana plug/elbowed banana plug leads, 1 set of safety test probes, 1 x 1.5 V LR6 battery · CA 5003 delivered with 1 set of silicone straight banana plug/elbowed banana plug leads, 1 set of safety test probes, 1 x 9 V 6LR61 battery · CA 5005 delivered with 1 MN89 AC clamp, 1 set of silicone straight banana plug/elbowed banana plug leads, 1 set of safety test probes, 1 x 9 V 6LR61 battery ACCESSORIES / REPLACEMENT PARTS Accessories kit for electricians CMI214S current measurement lead See all the accessories on page 32 P01295459Z P03295509 CONTENTS · 1 CA 5011 multimeter · 1 set of silicone straight banana plug/elbowed banana plug leads · 1 set of safety test probes · 1 x 9 V 6LR61 battery ACCESSORIES / REPLACEMENT PARTS Accessories kit for electricians PVC test-probe lead with insulated elbowed male plug Ø 4 mm (x 2) See all the accessories on page 32 P01295459Z P01295456Z 222 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com UNIVERSAL TEST & MEASUREMENT > DIGITAL MULTIMETERS > SELECTION GUIDE CHOOSE YOUR DIGITAL MULTIMETER CA 702 page 24 2000-count display 6000-count display 100,000-count display Bargraph Bi-mode bargraph (full scale central zero) Backlighting AVG measurement method TRMS AC/DC measurement method TRMS AC+DC measurement method Autoranging Min Max Peak AC and DC voltage up to 600 V AC and DC voltage up to 1,000 V No-contact voltage detection Low-impedance calibre (LowZ) LowZ voltage with low-pass filter AC and DC current Current with clamp A calibre 10 A calibre Resistance Audible continuity Semi-conductor test Frequency Capacitance dB Temperature USB communication Data storage CAT III 1000 V CAT IV 600 V CA 703 page 24 CA 5231 page 24 CA 5233 page 24 CA 5273 page 25 CA 5275 page 25 CA 5277 page 25 CA 5292 page 26 CA 5293 page 26 10,000 30,000 measurements measurements TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 323 UNIVERSAL TEST & MEASUREMENT > DIGITAL MULTIMETERS > CA 702 - CA 703 | CA 5231 - CA 5233 CA 702 - CA 703 REF. : P01191739Z REF. : P01191740Z CA 5231 - CA 5233 REF. : P01196731 REF. : P01196733 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology 600 V IEC CAT IV 61010-2-033 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology 54 1000 V 600 V IEC CAT III CAT IV 61010-2-033 IP TRMS STRENGTHS · Compact and ergonomic · AC/DC voltage up to 1,000 V · AC/DC current up to 600 A with 1,000/1 current clamp (option) STRENGTHS · Pocket format · Built-in test probes · Easy to handle and safe · Built-in torch SPECIFICATIONS Display Calibre selection Vdc / accuracy Vac / accuracy (40-400 Hz) No-contact voltage detection Idc / accuracy Protection IAC / accuracy Protection Resistance · Accuracy · Protection Diode test · Test signal · Protection Audible continuity · Buzzer · Protection Torch Standards Power supply Miscellaneous Dimensions / weight CA 702 CA 703 2000 points Automatic (AUTORANGE) 200 mV / ± 0.5 % R + 3 D 2.000 V; 20.00 V; 200.0 V; 600 V / ± 1.2 % R + 3 D > 600 V / outside specifications 2.000 V; 20.00 V / ± 1.0 % R + 8 D 200.0 V; 600 V / ± 2.3 % R + 10 D > 600 V / outside specifications Yes Yes 200.0 A; 2,000 A ± 2.0 % R + 8 D 20.00 mA; 200.0 mA ± 2.0 % R + 8 D 200 mA / 500 V electronic fuse 200.0 A; 2,000 A ± 2.5 % R + 10 D 20.00 mA; 200.0 mA ± 2.5 % R + 10 D Protection 200 mA / 500 V Electronic fuse 200.0 / ± 0.8 % R + 5 D · 2.000 k. 20.00 k. 200.0 k / ± 1.2 % R + 5 D 2.000 M / ± 5.0 % R + 5 D 20.00 M / ±10.0 % R + 5 D · 600 Vrms 1.999 V · V Test 1.5 V · I Test 1 mA · 600 Vrms 199.9 · R < approx. 60 · 600 Vrms Yes Yes IEC 61010 1000 V CAT III / 600 V CAT IV 2 x 1.5 V LR03 batteries Built-in test probe leads 104 x 55 x 32.5 mm / 145 g CONTENTS CA 702 and CA 703 delivered with 2 x 1.5 V LR03 batteries ACCESSORIES / REPLACEMENT PARTS 1.5 V LR03 battery 200 x 100 x 40 mm soft case P01296032 P01298065Z SPECIFICATIONS Display Backlighting Acquisition Autorange / Manual range Best accuracy AC voltage LowZ AC voltage DC voltage AC/DC current Resistance measurement Audible continuity Diode test Frequency Duty cycle Capacitance Temperature No-contact voltage detection (NCV) Display Hold Relative mode Min-Max Power supply Ingress protection Standards Dimensions / weight CA 5231 CA 5233 6,000-count display + 61-segment bargraph Yes True RMS AC Yes / Yes 0.02% 6 calibres / 1,000 V / resolution: 0.01 mV Bandwidth: 45 Hz ... 1 kHz Yes 6 calibres / 1000 V / resolution: 0.01 mV With 1 AC or DC clamp (1 mV/A) as an option 2 calibres: 10 A / 6 A 1 calibre: 600 A Resolution 0.001 A Resolution: 0.1 A 6 calibres / 60 M / resolution: 0.1 Yes Yes 3 calibres: up to 3 kHz Yes 6 calibres / 1,000 F Resolution: 0.01 nF 2 calibres -20 °C to 760 °C -4 °F to 1,400 °F Resolution: 0.1° Yes Yes Yes Yes Yes Yes 1 x 9 V 6LR61 battery IP54 IEC 61010-1, IEC 61010-1, IEC 61010-2-033 IEC 61010-2-033 CAT IV 600 V / CAT III 1000 V CAT IV 600 V / CAT III 600 V 155 x 75 x 55 mm / 320 g ADDITIONAL INFO · The CA 5231 can also be delivered complete with its MINI03 100 AAC current clamp: CA 5231 complete kit.............................. P01196734 CONTENTS CA 5231 delivered with: · 1 set of red/black test-probe leads · 1 x 9 V 6LR61 battery CA 5233 delivered with: · 1 set of red/black test-probe leads · 1 TC-K adapter for DMM · 1 wire K thermocouple · 1 x 9 V 6LR61 battery ACCESSORIES / REPLACEMENT PARTS Accessories kit for electricians PVC test-probe lead, insulated elbowed male plug Ø 4 mm (x 2) See all the accessories on page 32 P01295459Z P01295456Z 242 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com UNIVERSAL TEST & MEASUREMENT > DIGITAL MULTIMETERS > CA 5273 | CA 5275 - CA 5277 CA 5273 REF. : P01196773 CA 5275 - CA 5277 REF. : P01196775 REF. : P01196777 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology 54 TRMS 1000 V CAT III 600 V CAT IV IEC 61010-2-033 IP Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology 54 TRMS 1000 V 600 V IEC IP AC+DC CAT III CAT IV 61010 STRENGTHS · Large 6,000-count display · Double backlit display · Temperature and capacitance measurements · Bargraph central zero mode · Min/Max memorization STRENGTHS · 10 V resolution · Current measurement from 1 A · Measurement of ionization currents · Min / Max / Peak+ / Peak- acquisition · Differential (X) and relative (X / X%) measurements SPECIFICATIONS Display Bargraph (63 elements) Acquisition Measurement range Autoranging Manual ranges AC/DC voltage Typical accuracy (VDC) Bandwidth (VAC) LowZ AC voltage AC/DC current Resistance measurement Audible continuity / Diode test Frequency Capacitance Temperature Hold Min / Max (100 ms) Automatic power-off Safety Ingress protection Power supply Dimensions / weight CA 5273 2 x 6,000 counts backlit Bi-mode (full scale / central zero) TRMS AC / DC 5 measurements / second Yes Yes 600.0 mV / 6.000 V / 60.00 V / 600.0 V / 1000 V 0,2% + 2 cts 40 Hz to 3 kHz Low-impedance setting with low-pass filter 6.000 A / 10.00 A (20 A/30 s) 600.0 / 6000 / 60.00 k / 600.0 k 6.000 M / 60.00 M Yes / Yes 600.0 Hz / 6.000 kHz / 50.00 kHz 8 cal.: 6.000 nF to 60.00 mF -59.6 °C to +1200°C -4°F to 2192 °F Yes Yes Yes (deactivatable) IEC 61010-1, IEC 61010-2-033 CAT IV 600 V / CAT III 1000V IP54 1 x 9V 6LR61 battery 90 x 190 x 45 / 400 g ADDITIONAL INFO · 5 measurements / s · 12-bit converter · 3-year warranty CONTENTS CA 5273 delivered with: · 1 set of banana leads · 1 set of test probes · 1 x 9 V 6LR61 battery · 1 K-thermocouple temperature sensor ACCESSORIES / REPLACEMENT PARTS Accessories kit for electricians PVC lead with test probe, elbowed Ø 4 mm insulated male plug (x 2) See all the accessories on page 32 P01295459Z P01295456Z SPECIFICATIONS Display Bargraph Acquisition Measurement rate CA 5275 CA 5277 2 x 6,000 counts, backlit 63 elements, bi-mode (full scale / central zero) TRMS AC / DC / AC+DC 5 measurements / second Automatic / Manual ranges Yes / Yes AC/DC/AC+DC voltage 60.00 mV / 600.0 mV / 6 V / 60.00 V / 600.0 V / 1000 V Typical accuracy (Vdc) 0.09% + 2 cts Bandwidth (Vac) 40 Hz to 10 kHz LowZ AC voltage Low-impedance setting with low-pass filter AC/DC/AC+DC current 6000 µA / 60.00 mA / 600.0 mA / 6.000 A / 10.00 A (20A/30s) Ionization current 0.2 µA to 20.0 µAdc Resistance measurement 600.0 / 6000 / 60.00 k / 600.0 k 6.000 M / 60.00 M Audible continuity / Diode test Yes / Yes Frequency 600.0 Hz / 6.000 kHz / 20.00 kHz Capacitance 6.000 nF / 60 nF / 600 nF / 6 F / 60 F / 600 F / 6 mF / 60 mF Temperature No -59.6 °C to +1200 °C -4°F to 2192 °F Hold Yes Min / MAX (100 ms) Yes Peak+ / Peak- (1 ms) No Yes Differential (X) / RELative (X/X%) measurements No Yes Automatic power-off Yes (deactivatable) Safety IEC 61010-1, IEC 61010-2-033 CAT IV 600 V / CAT III 1000 V Ingress protection IP54 Power supply Dimensions / weight 1 x 9V 6LR61 battery 90 x 190 x 45 / 400 g ADDITIONAL INFO · 5 measurements / s · 12-bit converter · 3-year warranty CONTENTS · CA 5275 delivered with a set of banana plugs, a set of test probes, a 9 V battery, a shoulder bag, a MultiFix mounting accessory and a quick start guide · CA 5277 same as CA 5275 plus a K-thermocouple temperature sensor ACCESSORIES / REPLACEMENT PARTS Accessories kit for electricians PVC lead with test probe, insulated elbowed male plug Ø 4 mm (x 2) See all the accessories on page 32 P01295459Z P01295456Z TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 325 UNIVERSAL TEST & MEASUREMENT > GRAPHICAL DIGITAL MULTIMETERS > CA5292 - CA5293 | CA5292BT - CA5293BT CA 5292-CA 5293|CA 5292BT-CA 5293BT REF. : P01196802 REF. : P01196803 REF. : P01196812 REF. : P01196813 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology 67 1000 V 600 V IEC IP CAT III CAT IV 61010-2-033 STRENGTHS · 320 x 240 pixels colour liquid crystal matrice screen, high readability, black background · Data storage: 30,000 measurements (CA 5293) and 10,000 measurements (CA 5292) · Adjustable backlit screen · Multiple analytical tools: time/date-stamped MIN/MAX/AVG and PEAK · Bandwidth: 200 kHz · Basic accuracy: 0.02 % · Multi-parameter display: 1 main and 3 secondary measurements · 4 x 100,000-count displays and TRMS AC+DC converter CONTENTS CA 5292, CA 5292BT and CA 5293, CA 5293BT delivered with: · 1 bag · 4 x NiMH 2400 mAH 1.5 V rechargeable batteries · 1 USB charger · 1 set of 2 x 1.5 m straight/straight, red / black cables · 1 set of red/black CAT IV 1 kV test probes · 1 USB optical cable · SX-DMM software ACCESSORIES / REPLACEMENT PARTS MTX329X calibration software Kit of 4 NiMH batteries HX0059B HX0051B ADDITIONAL INFO · Battery life of up to 100 hours · SX-DMM software (supplied) for real-time processing of the results on a PC · Android application available from GOOGLE PLAY · Waveform mode for viewing an automatic waveform from 10Hz to 600Hz SPECIFICATIONS · Bandwidth: 100 kHz to 200 kHz · Temperature measurement with K/J thermocouple or Pt sensor from -200 °C to +1200 °C · Current measurement by direct reading with clamp (integration of the ratio) · Numerous additional measurement functions: low-pass PWM filter (variable speed drive), VLowZ low impedance (500 k), dB/dBm measurement, duty cycle, pulses, diode tests: Zener or LED... · A "reference" multimeter with 100 kcts and display of its specifications associated with a RELative mode · Simplified parameterization of the number of measurements, the interval (0.2 s to 24 hrs), the duration, the memory capacity, etc. · Internal storage: up to 30 measurement sequences (CA 5293) · Zoom function on stored curves · USB or Bluetooth communication depending on models CA 5292 / CA 5292BT CA 5293 / CA 5293BT Display 4 x 100,000 counts, TRMS Bargraph 40 elements or central zero mode Measurement rate 5 measurements /second DC, AC and AC+DC voltages Measurement range 10V to 600VAC/1,000V DC Calibres 100 mV* / 1,000 mV / 10 V / 100 V / 1,000 V Resolution 1 V / 10 V / 0.1 mV / 1 mV / 10 mV DC accuracy 0.03 % 0.02 % AC and AC+DC bandwidth 100 kHz 200 kHz AC and AC+DC accuracy 0.3 % 0.3 % VLowZ AC 500 k DC, AC and AC+DC current Measurement range 100A to 20A (30s) Calibres 1,000 A / 10 mA / 100 mA / 1,000 mA / 10 A 10 A / 20 A (30 s max) Resolution 10 nA / 0.1 A / 1 A / 10 A / 100 A / 1,000 A DC accuracy 0.08 % AC and AC+DC bandwidth 50 kHz AC and AC+DC accuracy 0.3 % Frequency Measurement range 1Hz to 5MHz Frequency calibres 10 Hz / 100 Hz / 1 kHz / 10 kHz / 100 kHz / 1 MHz / 5 MHz Resolution 0.0001 Hz / 0.001 Hz / 0.01 Hz / 0.1 Hz / 1 Hz / 10 Hz / 100 Hz Resistance and continuity Resolution 10m to 100M Calibres 100 * / 1 k / 100 k / 1,000 k / 10 M / 100 M Resolution 0,001 / 10 m / 100 k / 10 / 10 / 1 k Basic accuracy 0.07 % Audible continuity detection < 20 Diode test Voltage measurement Diodes in open circuit < 26 Vmax at 10 mA Capacitance Measurement range 1pF to 10mF Calibres 1 nF / 10 nF / 100 nF / 1,000 nF / 10 F / 100 F / 1 mF / 10 mF Resolution 1 pF / 10 pF / 0.1 nF / 1 nF / 0.01 F / 0.1 F / 1 F / 10 F Temperature with Pt100/1000 and K/J thermocouples Operating ranges -200 °C to +800 °C with Pt and -40 °C to +1200 °C with K thermocouple Accuracy 0.1 % Other functions MAX/MIN/AVG - PEAK On all the main time/date-stamped quantities - Secondary measurement REL Relative value: REF - Main measurement PWM filter 4th-order 300 Hz low-pass filter for measurements on variable speed drives of asynchronous motors SPEC Display of measurement tolerance + Smin + Smax GRAPH Trend of the main measurement on variable time base from 1min 28s à 1h 13min 20s WAVEFORM Graphical display of a signal up to 600 Hz in auto mode Secondary measurements 3 measurements + main measurement Measurement storage 10,000 30,000 General specifications Type of display Colour graphical display (70 x 52) with backlighting and black background on 4 x 100,000 count displays PC interfaces* USB optical connector or Bluetooth (option) SX-DMM software Power supply Charger or 4 x AA batteries or NiMH rechargeable batteries Safety / EMC Safety as per IEC61010-1 1000 V CAT III EMC as per EN61326-1 IEC 61010-2-033 - 1000 V CAT III - 600 V CAT IV Environment Storage -20 °C to +70 °C Operation 0 °C to +40 °C Mechanical specifications Dimensions (L x D x H): 196 x 90 x 47.1 mm / Weight: 570 g Ingress protection IP67 * Manual access 262 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com UNIVERSAL TEST & MEASUREMENT > PORTABLE DIGITAL OSCILLOSCOPES WITH 2 ISOLATED CHANNELS > CA 922 - CA 942 CA 922 - CA 942 600 V CAT III REF. : P01192200 REF. : P01194200 TRMS TRMS AC+DC IEC 61010 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS 3in1 · 20 or 40 MHz oscilloscope with 2 channels · Double 8,000-count multimeter · Double harmonic analyser · 3.5" colour LCD optimized for maximum display · Integrated multilingual interactive help function · Recording and recovery of data on PC · Practical with its USB communication using the SCPI protocol · Stand-alone, powered by NiMH battery with USB charger ADDITIONAL INFO · The same connection technology is used for all the modes: 2 BNC inputs for sensor or BNC/banana adapter delivered CONTENTS CA 922 and CA 942 depending on model: · BNC-Banana adapters: 2 for the CA 922, 1 for the CA 942 · Set of straight-elbowed moulded PVC cables (red/black) 1.5 m long: 2 for the CA 922, 1 for the CA 942 · Set of red/black crocodile clips: 2 for the CA 922, 1 for the CA 942 · 1 x 1/10 600V sensor for the CA942 · Set of red/black CAT IV 1000V test probes: 2 for the CA 922, 1 for the CA 942 · Jack-USB cable + USB WALLPLUG · USB optical cable · Bag ACCESSORIES / REPLACEMENT PARTS PWM kit = MLI01 filter + E27N clamp Calibration software Power supply kit with jack/USB cable and USB charger SX METRO software: SX-METRO/P BNC accessories, see page P01102188 HX0099 P01103080 SX-METRO/P 153 - 217 SPECIFICATIONS Complete oscilloscope · 2 x 600V CAT III isolated channels, display of automatic measurements and cursors · Simple MATH functions (+,-,x,/ inversion) with automatic scaling · Fast Autoset in <5 s, range >10 Hz from 10 mVpp to 400 Vpp · Simple or complex triggering on edge or pulse, associated with HF or LF filters · Acquisition with different modes: peak detect, averaging or envelope, as well as time-based zoom function. 2 independent 8,000-count TRMS digital multimeters AC, DC and AC+DC voltage and current measurements, resistance, continuity, capacitance, frequency and power values (combination of two measuring channels), as well as temperature (K thermocouple or infrared sensor), motor rotation speed (optical tachometer), testing of diodes and components and single-phase or balanced three-phase power measurements. 2 channels for Harmonic Analysis 2 channels up to the 31st order, with a fundamental frequency between 40 and 450 Hz. Display of total VRMS , THD and the harmonic order selected (%fundamental, phase, frequency, VRMS). Data storage Communication & PC software SX-METRO CA 922 CA 942 HMI Type of display 3.5" colour TFT Resolution 320x240 LED backlighting Display mode 2,500 real on-screen acquisition points Display of curves on screen 2 curves + 2 references + memory trace or mathematical calculation Controls Integrated interactive help function Direct adjustments on front panel & on-screen menus via browser (main & secondary without "hidden menus") 14 languages: English, French, German, Spanish, Italian, Swedish, Romanian, Russian, Finnish, etc. OSCILLOSCOPE MODE Vertical deflection Bandwidth 20 MHz 40 MHz Bandwidth limiter 1.5 MHz, 5 kHz Number of channels 2 totally isolated channels Input impedance 1 M ±0.5%, approx. 17 pF Maximum input voltage 600 V CAT III Derating -20 dB per from 100 kHz Vertical sensitivity 5 mV to 200 V/div Horizontal deflection Sweep speed 25 ns/div to 200 s/div Roll mode: 100 ms to 200 s/div Horizontal zoom Zoom factor: x1, x2, x5 Triggering Mode Automatic, triggered, one-shot & Triggered Roll Type Edge, pulse width (20 ns 20 s) Coupling Sensitivity AC or DC (depending on coupling of triggering channel); HF, LF or noise rejection 1.2 divisions peak-peak up 1.2 divisions p-p up to up to 20 MHz to 40 MHz Digital data storage Maximum sampling rate 2 GS/s in ETS mode 50 MS/s in one-shot mode on each channel Vertical resolution 9 bits Memory depth 2,500 points per channel User storage 2 MB for storing the files: trace (.trc), text (.txt), configuration (.cfg), image files (.bmp) GLITCH mode Duration 20 ns 1,250 Min/Max pairs Display modes Envelope, Averaging (factors 2 to 64) and XY (vector) Other functions MATH functions Channel inversion, addition, subtraction, multiplication and division (adjustable scaling) Cursor measurements 2 cursors: simultaneous V, T, dV and dt 4-digit display resolution Automatic measurements 18 time-based or level measurements, phase measurement MULTIMETER MODE General specifications Operating modes AC, DC and AC+DC voltage Resistance 2 channels, 8,000-count display + min/max bargraph Graphical recording of 2,700 measurements (5 min to 1 month) Absolute or relative display (absolute, deviation, ref, ref%) Monitoring (instantaneous, Min, Max, Avg) Ranges from 600 mV to 600 VRMS, 800 mV to 800 VDC VDC accuracy: 1%R +20D 50 kHz bandwidth Range from 80 to 32 M - Accuracy 2%R+10D 10 ms quick continuity test Capacitance Ranges from 5 nF to 5 mF Basic accuracy 2%R+10D Other measurements Frequency, rotation speed, 3.3 V diode , temperature measurement (using K thermocouple and infrared sensor) POWER Measurements Single-phase and balanced three-phase active power values (with or without neutral), simultaneous display of current - PF HARMONICS MODE Multi-channel analysis 2 channels, 31 orders, frequency of fundamental from 40 to 450 Hz Simultaneous measurements Total VRMS, THD and selected order (%fundamental, phase, frequency, VRMS) GENERAL SPECIFICATIONS Screenshots PC communication Power supply Safety / EMC Mechanical specifications Up to 100 files in standard ".bmp" format, viewable on the instrument Isolated optical USB interface SX-Metro application software for PC available as an option 6 x LR6 batteries or 6 x type-AA NiMH rechargeable batteries Battery life up to 8.5 hours JACK/USB cable with adapter Fast charging in 3 hours Safety as per IEC61010-1 Ed3 600 V CAT III EMC as per EN61000-3, 2001 & EN61326-1, 2006 214 x 110 x 57 mm 1.2 kg with batteries moulded elastomer casing TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 327 UNIVERSAL TEST & MEASUREMENT > AMMETERS WITH FLEXIBLE CURRENT SENSORS > MA400D-170 - MA400D-250 - MA4000D-350 MA400D-170 - MA400D-250 - MA4000D-350 REF. : P01120575Z REF. : P01120576Z REF. : P01120577Z Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology 600 V CAT IV TRMS STRENGTHS · Compact, lightweight and simple to use · Direct current readings · Measurement from a few tens of mA · MAX HOLD to store the maximum value SPECIFICATIONS Display range Measurement range Resolution Accuracy Clamping diameter / sensor length Bandwidth Power supply Safety Operating temperature Instrument weight Casing dimensions Length of built-in connection cable MA400D-170 / 250 4 Aac 40 Aac 400 Aac 0.020 A ... 3.999 A 4.00 A ... 39.99 A 40.0 A ... 399.9 A 1 mA 10 mA 100 mA ± (2% + 10 cts) ± (1.5% + 2 cts) ± (1.5% + 2 cts) MA400D-170: Ø 45 mm / 170 mm MA400D-250: Ø 70 mm / 250 mm 10 Hz ... 3 kHz 2 x 1.5 V AAA / LR batteries IEC 61010 CAT IV 600 V 0°C to +50°C Approximately 130 g 100 x 60 x 20 mm 0.8 m Display range Measurement range Resolution Accuracy Clamping diameter / sensor length Bandwidth Power supply Safety Operating temperature Instrument weight Casing dimensions Length of built-in connection cable MA4000D-350 40 Aac 400 Aac 4000 Aac 0.2 A ... 39.99 A 40.0 A ... 399.9 A 400 A ... 3999 A 10 mA 100 mA 1 A ± (2% + 10 cts) ± (1.5% + 2 cts) ± (1.5% + 2 cts) MA4000D-350: Ø 100 mm / 350 mm 10 Hz ... 3 kHz 2 x 1.5 V LR06 batteries IEC 61010 CAT IV 600 V 0°C to +50°C Approximately 130 g 100 x 60 x 20 mm 0.8 m ADDITIONAL INFO · MA400D: measurement from 20 mA AC CONTENTS 1 ammeter delivered with: · 2 x 1.5 V LR06 batteries · 1 Velcro mounting strap ACCESSORIES / REPLACEMENT PARTS Bag 120 x 200 x 60 MULTIFIX accessories See all the accessories on page 32 P01298074 P01102100Z 282 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com UNIVERSAL TEST & MEASUREMENT > CLAMP MULTIMETERS > SELECTION GUIDE CHOOSE YOUR CLAMP MULTIMETER F201 page 30 Clamping Ø 34 mm Clamping Ø 48 mm Clamping Ø 60 mm AC current DC current Automatic DC Zero True Root Mean Square (TRMS) measurements Measurement with DC component (AC+DC) Measurement on non-linear loads 6,000-count display 10,000-count display Backlighting AC and DC voltage measurement Resistance Audible continuity Semi-conductor test Frequency Temperature Active power (W) Apparent and reactive power (VA, var) Power Factor (PF/DPF) AC / DC / AC+DC power measurements Phase rotation (2 wires) Total Harmonic Distortion (THDf% / THDr%) Harmonic decomposition Harm0...Harm25 Crest Factor (CF) Deactivatable automatic AC/DC Motor InRush TrueInrush current surge with load Min. Max. Peak X differential measurement X/X relative measurement Input adapter (external sensor) Data-logging PC interface / Bluetooth interface CAT IV 600 V CAT IV 1000 V F203 page 30 F205 page 30 F401 page 31 F403 page 31 F405 page 31 F407 page 87 x 3 F603 page 31 F605 page 31 F607 page 87 x 3 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 329 UNIVERSAL TEST & MEASUREMENT > CLAMP MULTIMETERS > F201 - F203 - F205 F201 - F203 - F205 REF. : P01120921 REF. : P01120923 REF. : P01120925 600 AAC 900 ADC TRMS 1000 V CAT III 600 V CAT IV True InRush IEC 61010-2-032 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · 34 mm clamping diameter · Compact format · TRMS AC+DC with the F205 clamp SPECIFICATIONS Clamping diameter Display Resolution Number of values displayed Type of acquisition Autorange Automatic AC/DC detection Aac Adc Aac+dc Best accuracy Vac Vdc Vac+dc Best accuracy Frequency for V / I Resistance Audible continuity Diode test (semi-conductor junction) Temperature (type K) Adapter Single phase and total three-phase power values Active (W) Reactive (var) Apparent (VA) PF Harmonic analysis THDf / THDr Phase rotation (2-wire method) Functions Overcurrent measurement Motor InRush Evolution of load (TrueInrush) Hold Min / MAX Peak+ / PeakRELative X Differential X/X(%) Auto Power Off Electrical safety as per IEC 61010-1, IEC 61010-2-032 Power supply Dimensions / weight F201 LCD TRMS AC F203 F205 Ø 34mm Backlit LCD 6,000 counts 1 TRMS AC/DC TRMS AC, DC, AC+DC Yes Yes 600 A 900 A 600 A (900 A peak) 1 % of reading+ 3 counts 1000 V 1000 V 1000 V (1400 V peak) 1 % of reading+ 3 counts Yes / Yes 60 k Adjustable from 1 to 599 Yes °C: -60.0 to +1,000 °C °F: -76 to +1,832 °F Yes AC, DC, AC+DC Yes Yes Yes Yes Yes / Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 600 V CAT IV - 1000 V CAT III 1 x 9 V 6LR61 78 x 222 x 42 mm / 340 g CONTENTS F201 delivered with: · 1 set of built-in PVC test-probe leads (black/red) / insulated elbowed male banana plug Ø 4 mm · 1 x 9 V 6LR61 battery · 1 Multifix bag · 1 mini-CD containing the User's Manual F203 same as F201 plus 1 wire thermocouple with built-in insulated Ø 4 mm banana connections with 19 mm spacing F205 delivered with: · 1 set of PVC leads (black/red) with insulated elbowed male banana plug Ø 4 mm / insulated straight male banana plug Ø 4 mm · 2 test probes / insulated female plug Ø 4 mm (black/red) · 1 safety crocodile clip (black) · 1 x 9 V 6LR61 battery · 1 Multifix shoulder bag · 1 mini-CD containing the User's Manual ACCESSORIES / REPLACEMENT PARTS See all the accessories on page 32 302 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com UNIVERSAL TEST & MEASUREMENT > CLAMP MULTIMETERS > F401 - F403 - F405 - F603 - F605 F401 - F403 - F405 - F603 - F605 REF. : P01120941 REF. : P01120943 REF. : P01120945 REF. : P01120963 REF. : P01120965 54 1000 AAC 2000 AAC 1500 ADC 3000 ADC TRMS 1000 V CAT IV IP True IEC InRush 61010-2-032 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS F40X Series · Low and medium-power LV applications · 48 mm clamping diameter F60X Series · High-power LV applications · 60 mm clamping diameter SPECIFICATIONS Clamping diameter Display Resolution Type of acquisition Autorange Automatic AC/DC detection Aac Adc Aac+dc Best accuracy Vac Vdc Vac+dc Best accuracy Frequency for V / I Resistance Audible continuity Diode test (semi-conductor junction) F401 TRMS AC F403 F405 F603 F605 Ø 48mm Ø 60mm Backlit LCD 10,000 counts TRMS AC/DC TRMS AC, DC, AC+DC TRMS AC/DC TRMS AC, DC, AC+DC Yes Yes 1,000 A 2,000 A 1,500 A 3,000 A 1,000 A 2,000 A (1,500 A (3,000 A peak) peak) 1 % of reading + 3 counts 1,000 V 1,000 V 1,000 V (1,400 V peak) 1 % of reading + 3 counts 1,000 V (1,400 V peak) Yes / Yes 100 k Adjustable from 1 to 999 Yes Temperature (type K) °C: -60.0 to +1,000 °C °F: -76 to +1,832 °F °C: -60.0 to +1,000 °C °F: -76 to +1,832 °F Adapter Single-phase and total three-phase power values Yes Yes Yes Yes Active (W) Reactive (VAR) Apparent (VA) PF / DPF Harmonic analyses THDf /THDr Phase rotation (2-wire method) Functions Overcurrent measurement Motor Inrush Evolution of load (TrueInrush) Hold Min / MAX Peak+ / PeakRELative X Differential X/X(%) Auto Power Off Electrical safety as per IEC 61010-1, IEC 61010-2-032 Power supply Dimensions / weight Yes Yes Yes Yes / Yes / Yes Yes Yes Yes Yes Yes / Yes / Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 1000 V CAT IV - 1000 V CAT III 4 x 1.5 V LR06 92 x 272 x 41 mm 600 g 111 x 296 x 41 mm 640 g ADDITIONAL INFO · See also the F407 & F607 with harmonic measurement, recording and wireless connection. CONTENTS F401 / F403 / F603 delivered with: · 1 set of PVC leads (black/red) with insulated elbowed male banana plug Ø 4 mm / insulated straight male banana plug Ø 4 mm · 2 test probes / insulated female plug Ø 4 mm (black/red) · 1 wire thermocouple with built-in insulated Ø 4 mm banana connections with 19 mm spacing · 4 x 1.5 V LR03 batteries · 1 Multifix shoulder bag · 1 mini-CD containing the User Manual F405 / F605 : · Same as F401 / F403 / F603 but without the wire thermocouple and with 1 black safety crocodile clip ACCESSORIES / REPLACEMENT PARTS See all the accessories on page 32 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 331 UNIVERSAL TEST & MEASUREMENT > ACCESSORIES / REPLACEMENT PARTS ACCESSORIES / REPLACEMENT PARTS TESTERS CA 732 · 1.5 V LR03 battery........................................ P01296032 CA 745N · Set of red/black CAT III/IV test probes........... P01102152Z · Set of red/black test probes - Ø 2 mm, CAT II........................................... P01102153Z · Set of red/black test probes - Ø 4 mm, CAT II........................................................... P01102154Z · CA 753 universal measurement adapter for 2P+E sockets.......................................... P01191748Z · Velcro strap x 5............................................. P01102113 · 1.5 V LR03 alkaline battery........................... P01296032 · Bag compatible with MultiFix accessory, 120 x 200 x 60 mm...................................... P01298074 · MultiFix mounting accessory......................... P01102100Z CA 755, CA 757 · Set of black/red CAT III/IV test probes........... P01102152Z · Set of black/red Ø 2 mm test probes, CAT II.......P01102153Z · Set of black/red Ø 4 mm test probes, CAT II.......P01102154Z · MA101-250 current sensor for CA 757.......... P01120591 · CA 753 universal measurement adapter for 2P+E sockets.......................................... P01191748Z · Velcro strap x 5............................................. P01102113 · 1.5 V LR03 alkaline battery........................... P01296032 · Bag compatible with MultiFix accessory, 120 x 200 x 60 mm...................................... P01298074 · MultiFix mounting accessory......................... P01102100Z VOLTAGE DETECTORS CA 742, CA 742 IP2X, CA 762 and CA 762 IP2X · Measurement adapter for 2P+E socket, model CA 751 ..... P01101997Z · Universal measurement adapter for 2P+E socket, model CA 753 .............................. P01191748Z · Red test probe Ø2 mm .......................... P01102008Z · Black test-probe lead Ø2 mm ..................... P01102009Z · Adapter for safety rod (set of 2) .................... P01102034 · Crystal safety cap for test probe Ø2 mm (x10) .......... P01102033 · Set of 2 leads 0.25 m and 0.85 m long with Ø4 mm IP2X test probes ..................... P01295285Z · Set of 2 leads 1.5 m long with Ø4 mm IP2X test probes .... P01295462Z · MultiFix shoulder bag, 120 x 200 x 60 mm ............. P01298074 · IP2X CAT IV test probes ........................ P01102127Z · IP2X Ø4 mm test probes ....................... P01102128Z · Soft case, 200 x 100 x 40 mm with belt clip ............ P01298065Z · Shoulder bag no. 10 ........................... P01298012 · Wrist-strap ................................. P03100824 · 1 probe-holder cable 1.10 m long + 2 red/black ø 4 mm IP2X test probes ............................. P01102121Z CA 771, CA 771 IP2X, CA 773 and CA 773 IP2X · CAT IV test probes ............................ P01102123Z · Ø2 mm test probes ........................... P01102124Z · Ø4 mm test probes ........................... P01102125Z · Test-probe protector .......................... P01102126Z · IP2X CAT IV test probes ........................ P01102127Z · IP2X Ø4 mm test probes ....................... P01102128Z · CA 753 universal measurement adapter for European 2P+E power socket .................. P01191748Z · MultiFix shoulder bag, 120x320x60 mm ............. P01298076 · Crystal safety cap for test probe Ø2 mm (x10) ......... P01102033 ANALOGUE MULTIMETERS CA 5001, CA 5003 and CA 5005 · Accessories kit for electricians ................... P01295459Z · CMI214S current measurement lead............. P03295509 · Shoulder bag................................................ P01298033 · Soft case no. 5............................................. P01298036 · Hard case..................................................... P01298037 · Shoulder bag no. 21 with strap (250x165x60 mm)....................................... P06239502 CA 5001 · 1.5 V LR06 battery........................................ P01296033 · 0.5 A HRC fuse (x 10)................................... P01297028 · 5 A HRC fuse (x 10)...................................... P01297035 CA 5003 · 9 V 6LR61 battery........................................ P01100620 · MN11 LCA 200/0.2 clamp............................ P01120404 · 1.6 A HRC fuse (x 10)................................... P01297036 · 16 A HRC fuse (x 10).................................... P01297037 CA 5005 · 9 V 6LR61 battery........................................ P01100620 · MINI 09 clamp - 1 A / 100 MVDC.................. P01105109Z · MN11 LCA 200/0.2 clamp............................ P01120404 · 10 A HRC fuse (x 10).................................... P01297038 · 1 A HRC fuse (x 10)...................................... P01297039 CA 5011 · 9 V 6LR61 battery........................................ P01100620 · Crocodile wire grip (x 2)................................ P01102053Z · Insulation-piercing clip (x 2).......................... P01102055Z · Moulded PVC lead with straight male plug/insulated elbowed male plug Ø4 mm (x 2)................................................. P01295451Z · Moulded red/black silicone lead with straight male plug/insulated elbowed male plug Ø4 mm (x 2).................................. P01295453Z · Safety test probe (x 2)................................... P01295454Z · PVC test-probe lead, insulated elbowed male plug Ø 4 mm (x 2)................................. P01295456Z · Crocodile clip (x 2)........................................ P01295457Z · Ø 4 mm CAT II 300 V test probe (x 2)............ P01295458Z · Ø 2 mm CAT II 300 V test probe (x 2)............ P01295460Z · IP2X test-probe lead (x 2)............................. P01295461Z · Accessories kit for electricians...................... P01295459Z · CMI214S current measurement lead............. P03295509 DIGITAL MULTIMETERS CA 5231, CA 5233, CA 5273, CA 5275 and CA 5277 · 9 V 6LR61 battery........................................ P01100620 · Crocodile wire grips (x 2)............................... P01102053Z · Insulation-piercing clip (x 2).......................... P01102055Z · 40 kVdc / 28 kVac high-voltage probe........... P01102097 · MultiFix multi-position mounting accessory... P01102100Z · Moulded PVC lead with straight male plug/insulated elbowed male plug Ø4 mm (x 2).................................. P01295451Z · Moulded red/black silicone lead with straight male plug/insulated elbowed male plug Ø4 mm (x 2).................... P01295453Z · Safety test probe (x 2)................................... P01295454Z · PVC test-probe lead, insulated elbowed male plug (x 2)................................ P01295456Z · Crocodile clip (x 2)........................................ P01295457Z · Ø 4 mm CAT II 300 V test probe (x 2)............ P01295458Z · Ø 2 mm CAT II 300 V test probe (x 2)............ P01295460Z · IP2X test-probe lead (x 2)............................. P01295461Z · Accessories kit for electricians...................... P01295459Z CA 5231 · 100 AAC MINI 03 current clamp................... P01105103Z · PAC 15 400 AAC / 600 ADC current clamp..... P01120115 CA 5233, CA 5273 and CA 5277 · Safety thermocouple adapter (x 2)................. P01102106Z · Safety adapter and temperature probe, wire K sensor, -50°C to +450°C........ P01102107Z · CMI214S current measurement lea............... P03295509 CA 5292 and CA 5293 · Calibration software...................................... HX0059B · Pt100 adapter.............................................. HX0091 · Kit of 4 NiMH batteries.................................. HX0051B · External charger........................................... HX0053B · USB optical cable.......................................... HX0056Z · Safety adapter and 50°C to +450°C and wire K-sensor temperature probe.................. P01102107Z · Kit with PWM filter + E27 clamp................... P01102188 CA 922 and CA 942 · Kit with PWM filter + E27 clamp................... P01102188 · Power supply kit with USB/JACK cable and USB charger.................................. P01103080 · Calibration software...................................... HX0099 · PC acquisition software................................. SX-METRO /P CLAMP MULTIMETERS F200, F400 and F600 SERIES · MultiFix multi-position mounting accessory... P01102100Z · Moulded PVC lead with straight male plug/insulated elbowed male plug Ø4 mm (x 2).................................. P01295451Z · Moulded red/black silicone lead with straight male plug/insulated elbowed male plug Ø4 mm (x 2).................... P01295453Z · Safety test probe (x 2)................................... P01295454Z · PVC test-probe lead, insulated straight male plug Ø 4 mm (x 2).................... P01295455Z · PVC test-probe lead, insulated elbowed male plug Ø 4 mm (x 2)................... P01295456Z · Crocodile clip (x 2)........................................ P01295457Z · Ø 4 mm CAT II 300 V test probe (x 2)............ P01295458Z · IP2X test-probe lead (x 2)............................. P01295461Z · Accessories kit for electricians...................... P01295459Z · CMI214S current measurement lead............. P03295509 F400 and F600 SERIES · 1.5 V LR06 battery........................................ P01296033 · MultiFix shoulder bag 120x320x60 mm........ P01298076 F201 and F205 · 9 V 6LR61 battery........................................ P01100620 · MultiFix shoulder bag 120x245x60 mm......... P01298075 F203 · 9 V 6LR61 battery........................................ P01100620 · Safety thermocouple adapter (x 2)................. P01102106Z · Safety adapter and temperature probe, wire K sensor, -50°C to +450°C........ P01102107Z · MultiFix shoulder bag 120x245x60 mm......... P01298075 F403 and F603 · Safety thermocouple adapter (x 2)................. P01102106Z · Safety adapter and temperature probe, wire K sensor, -50°C to +450°C................... P01102107Z MA400D & MA4000D · Shoulder bag 120x200x60 mm..................... P01298074 · MultiFix accessories...................................... P01102100Z · Velcro strap (set of 5).................................... P01102113 See all our accessories on page 150 322 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com UNIVERSAL TEST & MEASUREMENT > NOTES NOTES TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 333 ELECTRICAL SAFETY > INFO AND ADVICE > ELECTRICAL INSTALLATION TESTING INFO AND ADVICE 34 EARTH AND RESISTIVITY TESTERS 56 INSTALLATION TESTERS 39 ELECTRICAL EQUIPMENT TESTERS 63 INSULATION TESTERS 45 OTHER TESTERS 68 CLAMP MULTIMETERS FOR LEAKAGE CURRENT 55 DATA PROCESSING SOFTWARE 74 ACCESSORIES 81 ELECTRICAL INSTALLATION TESTING The risks linked to incorrect use of electricity may include: - life-threatening danger for people, - threat of damage to electrical installations and property, - harmful effects on systems operation and equipment life spans. So the purpose of electrical installation testing is primarily to ensure that people and goods are kept safe and are protected in the event of a fault. It also facilitates preventive maintenance of installations, preventing serious faults which might prove expensive (production shutdown, etc.). To guarantee people's safety with regard to these installations and the electrical equipment connected to them, standards have naturally been developed and updated to take changes into account. The IEC 60364 standard and its various national equivalents published in each European country, such as NF C 15-100 in France or VDE 100 in Germany, specify the requirements concerning electrical installations in buildings. Chapter 6 of this standard describes the requirements for testing the compliance of an installation. The effectiveness of the safety measures implemented can only be guaranteed if regular tests prove they are operating correctly. This is why the standards cover not only the initial verifications when installations are commissioned, but also periodic testing whose frequency depends on the type of installation and equipment, its use and the legislation in the country involved. In addition, the tests must be carried out with measurement instruments that comply with the IEC 61-557 European standard ensuring user safety and reliable measurements. The electrical testing is divided into 2 parts: 1. V isual inspection to guarantee that the installation complies with the safety requirements (presence of an earth electrode, protective devices, etc.) and does not show any visible evidence of damage. 2. Measurements There are 4 main measurements required: 1. Earth 2. Continuity 3. Insulation 4. Tests of protective devices 1. EARTH To guarantee safety on residential or industrial electrical installations, one of the basic rules is that there must be an earth electrode. If there is no earth electrode, it may endanger people's lives and damage electrical installations and property. When a large enough area is available to set up stakes, you should measure the earth with the traditional 3-pole method, also known as the 62 % method. When the 62 % method is not applicable, however, other methods can be used. There are many methods for measuring the earth (1P live earth, PH-PE loop impedance, selective earth with 1-clamp method, etc.), some more suitable than others, depending on the type of earth connection system, the type of installation (residential, industrial, urban, rural, etc.), the possibility of cutting off the power, the area available for planting stakes, etc. 2. CONTINUITY The purpose of continuity measurement is to check the continuity of the protective conductors and the main and supplementary equipotential bonds. The test is carried out using a measuring instrument capable of generating a no-load voltage of 4 to 24 V (DC or AC) with a minimal current of 200 mA. The resistance measured must be lower than a threshold specified by the standard applicable to the installation tested, which is usually 2 . As the resistance value is low, the resistance of the measurement leads must be compensated, particularly if very long leads are used. Example : Approximate measurement of earth resistance by the Zs (Ph-PE) loop measurement method in a TT-type earthing system 3. INSULATION Good insulation is essential to prevent electric shocks. This measurement, usually carried out between active conductors and the earth, involves injecting a DC voltage, measuring the current and thus determining the insulation resistance value. The power must be switched off and the installation must be disconnected before performing this test to ensure that the test voltage will not be applied to other equipment electrically connected to the circuit to be tested, particularly devices sensitive to voltage surges. According to the IEC 60364 standard, the minimum insulation resistance values must be as follows: Rated voltage of circuit V SELV or PELV 500 V including PELV > 500 V DC test voltage V 250 500 1000 Insulation resistance M 0.5 1.0 1.0 4. TESTS OF PROTECTIVE DEVICES Fuses / Circuit-breakers To check the specifications of the protective devices such as fuses or circuit-breakers, a fault loop impedance measurement is carried out to calculate the corresponding short-circuit current. A visual inspection can then be used to check that the sizing is correct. A fuse table directly integrated in certain installation testers can be used to check automatically that the fuses are correctly sized. Residual Current Devices (RCDs): types AC, A and B RCDs, which detect earth leakage currents, can be tested using two methods: - the basic test, also called a pulse test, which determines the trip time (in milliseconds) - the step test, which determines the trip time and trip current, thus detecting any RCD ageing. Type-B RCDs are designed to provide a specified response for DC-only leakage currents. A specific test is then required to check RCDs of this type. 5. OTHER RECOMMENDED MEASUREMENTS When testing low-voltage installations, other measurements are recommended (mandatory in some countries) such as: - T he voltage drop DV% in the cables, obtained by means of two line-impedance measurements to check that their cross-sections are appropriate - T he correct phase order in three-phase systems, thus ensuring that rotating machines turn in the right direction - T he installation's voltage and frequency, allowing identification of any poor connections Detection of phase current unbalance by measuring with a clamp and first-level assessment of the harmonic content are useful additions to any installation analysis. Example : RCD test via connection in a wall socket in TT-type earthing systems.. 342 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > INFO AND ADVICE > INSULATION MEASUREMENT ELECTRICAL SAFETY INSULATION MEASUREMENT To ensure that electrical equipment and installation operate correctly in total safety, all the conductors are insulated: sheathing for cables, varnish for windings. When the quality of these insulating materials diminishes, leakage currents may flow from one conductor to the other and, depending on the extent of the insulation faults (the worst being a short-circuit), may cause serious damage. Equipment with faulty insulation may break down, burn or cause a fault on the installation itself, thus triggering protective devices and shutting down the whole installation... Furthermore, some particularly sensitive installations (operating theatres in hospitals, chemical Industries, etc.) are built using an IT-type earthing system (cf. IEC 60364-6), which tolerates an initial line-earth insulation fault and only shuts down the installation if a second fault occurs. Measurements are needed to prevent and prepare for the hazards linked to insufficient or damaged insulation. These measurements concern both the electrical equipment and the installations to which it is connected. These measurements are carried out during commissioning on new or reconditioned items, and then repeated regularly to monitor their evolution over time. INSULATION RESISTANCE MEASUREMENT AND DIELECTRIC TESTING These two concepts, which characterize the quality of an insulant, require further explanation as they are too frequently confused. Dielectric strength testing, also called "breakdown testing", measures an insulant's ability to withstand a medium-duration voltage surge without sparkover occurring. In reality, this voltage surge may be due to lightning or the induction caused by a fault on a power transmission line. The main purpose of this test is to ensure that the construction rules concerning leakage paths and clearances have been respected. This test is often performed by applying an AC voltage but can also be done with a DC voltage. This type of measurement requires a dielectrometer. The result obtained is a voltage value usually expressed in kilovolts (kV). Dielectric testing may be destructive in the event of a fault, depending on the test levels and the available energy in the instrument. For this reason, it is reserved for type tests on new or reconditioned equipment: only equipment that passes the test will be put into service. Insulation resistance measurement, however, is non-destructive under normal test conditions. Carried out by applying a DC voltage with a smaller amplitude than for dielectric testing, it yields a result expressed in k, M or G. This resistance indicates the quality of the insulation between two conductors and provides a good idea of the risks of leakage currents. Because it is non-destructive, it is particularly useful for monitoring insulant ageing during the operating life of electrical equipment or installations. This means it can be used as a basis for preventive maintenance. This measurement is performed using an insulation tester, also called a megohmmeter. MEASURING LEVELS OF INSULATION In concrete terms, first of all the installation or equipment is checked to ensure that no voltage is present in it. Then a DC test voltage is applied and the insulation resistance value is read. When measuring an insulation in relation to the earth, you are advised to place the positive pole of the test voltage on the earth to prevent earth polarization problems when carrying out multiple tests. All the standards concerning electrical installations or equipment specify the measurement conditions and minimum thresholds to be respected for insulation measurements. INSULATION MEASUREMENT APPLICATIONS Insulation measurement on electrical installations Insulation test before powering up Before powering up a new installation, its insulation must be tested. Two types of measurements are required: · Verification of the conductors: this checks that none of the conductors, cut-off devices or connection equipment has suffered damage liable to cause an insulation fault. This is done before commissioning the installation, with all the receivers disconnected.. ·Verification of the whole installation in relation to the earth. 100 m 3 2 1 N + M Insulation test after powering up After powering up the installation, the insulation should be checked regularly to make sure there is no substantial drift away from the initial values. Because the method used is the same as for testing before powering up, the installations must be switched off. In both cases, the insulation will be considered acceptable if the insulation resistance measured is greater than the threshold specified by the applicable standard for the installation tested (NF C 15-100 in France, VDE 100 in Germany, European standard IEC 60364, IEEE 43-2000, etc.) Insulation measurement on motors, transformers, etc. Whether on electrical installations or on machines, the quality of the insulating materials deteriorates as time passes due to the stresses affecting the equipment. This deterioration reduces the electrical resistivity of the insulants, leading in turn to an increase in the leakage currents and causing incidents which may be serious in terms of the safety of people and property, but also in terms of production stoppage costs in industry. So, in addition to the measurements during commissioning of new or renovated equipment, regular insulation testing of installations and equipment helps to prevent such incidents by organizing preventive maintenance designed to detect ageing and therefore prevent premature deterioration of the insulation properties before they reach a level liable to cause the incidents described above. Deterioration of the equipment may occur naturally, but it is often also accelerated by external contaminants such as dust, oil, etc. It is therefore strongly recommended to monitor its insulation over time. To carry out this preventive maintenance effectively, the Chauvin Arnoux range of megohmmeters proposes the following functions: ·PI, DAR and DD quality ratios for a quick assessment of insulation quality, with the added advantage that they are not particularly influenced by temperature, making them easy to use without requiring correction of the results ·Automatic calculation of the insulation resistance at a reference temperature (CA 6549, CA 6550, CA 6555) ·Method based on the influence of test voltage variation (step voltage measurement) CRITERIA FOR CHOOSING AN INSULATION TESTER Here are a few tips to help you choose an insulation tester that matches your requirements. The application. What type of equipment will you be testing: electrical installations, switchgear, telephony, etc. Rated operating voltage, manufacturer recommendations, dedicated standards Test voltage: 50 100 250 500 1,000 2,500 5,000 10,000 15,000 Vdc Measurement range: k, M, G, T User comfort. Reading mode: needle display with logarithmic scale, digital LCD, analogue bargraph User-friendly features: programmable alarm thresholds, backlighting, remote control probe Operating mode. Hand-cranked generator, normal or rechargeable batteries Other measurements required: continuity, current, voltage, etc. Single-function or multi-function instrument, for testing installations or machines TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 335 ELECTRICAL SAFETY > INFO AND ADVICE > EARTH MEASUREMENT EARTH MEASUREMENT For residential or industrial installations, the presence of an earth connection is one of the basic rules to ensure that the electrical installation is safe. The absence of an earth connection may endanger people's lives and damage electrical installations and property. However, the presence of an earth connection does not guarantee safety and, even if the earth is correctly sized, only regular testing can ensure that it functions correctly. The standards for electrical installations, such as IEC 60364, NF C 15-100, etc., stipulate the general installation conditions to be applied in order to guarantee the safety of people, pets, farm animals and property by protecting them against the hazards and damage which may result from use of the electrical installations. When there is a large enough area available to set up stakes, earth measurement should be carried out with the traditional 3-pole method, also known as the 62 % method. There are a large number of different methods for earth measurements, however, and the right choice depends on the type of earthing system, the type of installation (residential, industrial, urban, rural, etc.), the possibility of switching off the power supply, the area available for setting up stakes, etc. LIST OF THE DIFFERENT EARTH MEASUREMENT METHODS Here is an overview of the most frequently-used measurement methods: The 62 % in-line measurement method (two stakes) Existing earth This method requires the use of two auxiliary electrodes (or "stakes") to allow current injection and provide the 0 V reference potential. The positioning of the two auxiliary electrodes in relation to the earth connection to be tested E(X), is crucial. For correct measurements, the "auxiliary connection" providing the reference potential (S) must not be positioned in the areas influenced by earths E & H due to the flow of the current (i). Statistics from the field have shown that the ideal method for guaranteeing the highest possible measurement accuracy involves placing the stake S at a point 62 % of the distance from E on the line EH. You must then make sure that the measurement does not vary significantly when moving the stake S by ± 10 % (S' and S") on either side of its initial position, while remaining on the line EH. If the measurement varies, it means that (S) is in an influence area, so the procedure should be repeated after increasing the distances. For a correct measurement, the stake H should be at least 25 metres away from the earth to be tested. For more accurate measurement, it is possible to use a 4-pole measurement method (adding a connection between the earth to be tested and the ES terminal of the measurement instruments) to minimize the resistance of the measurement leads, thus improving accuracy. This method is strongly recommended for low resistance values as the influence of measurement-lead resistance will then be considerable.. Line-PE loop measurement (only on TT system) In urban environments, it often proves difficult to measure earth resistances using auxiliary stakes because it is not possible to set up the stakes for reasons of space, concreting, etc. Loop measurement can then be used to test earths in urban environments without using stakes simply by hooking up to the mains power supply (mains socket). In addition to the earth to be measured, the loop resistance measured in this way includes the earth and internal resistance of the transformer and the resistance of the cables. As all these resistances are very low, the value measured is an overall earth resistance value. The actual earth resistance is therefore lower: Rmeasured > Rearth. The (overall) measurement error introduced by this method actually contributes to greater safety. The standards concerning electrical installations consider that the loop resistance (overall earth resistance) may be taken into account instead of the earth resistance to comply with the rules on protection against the risk of indirect contacts. Fuses/ circuit-breaker 3 2 1 N RCD PE Rtransfo Rearth Note: on TN or IT (impedant) systems, the loop impedance measurement can be used to calculate the short-circuit current and thus to size the protective devices correctly. Selective earth measurements For interconnected earths, selective earth measurement can be used for quick, safe testing. In this case, it is not necessary to isolate the installation (no need to open the earth bar) and, for loop measurements with 2 clamps or with an earth clamp, it is not necessary to set up stakes. For the earth clamp and for the 2-clamp method, all you have to do to find out the earth value and the value of the currents flowing in it is clamp the cable connected to the earth. An earth clamp comprises two windings: a generator winding and a receiver winding: - The clamp's "generator" winding develops an AC voltage at the constant level E around the clamped conductor; a current I = E / Rloop then flows through the resistive loop. - The "receiver" winding measures this current. - As E and I are known values, the loop resistance can be deduced from them. This case involves a network of parallel earths. Knowing that "n" resistances in parallel are equivalent to a resistance Raux with a negligible value, we can measure the local earth value Rx: Rloop = Rx + Raux (where Raux = resistance equivalent to R1...Rn in parallel) As Rx >> Raux', we obtain the result Rloop # Rx The 2-clamp method is an equivalent method. One clamp acts as the generator, while the second acts as the receiver. This method may be more practical in places where access is difficult or when a larger clamping diameter is required. Schematic diagram: earth clamp Single earth connection 3-pole method alias 62 % method Triangle method (2 stakes) 4-pole method Variant 62 % method (1 stake) Line-PE loop measurement Network of multiple parallel earths Selective 4-pole method Earth clamp Earth loop measurement with 2 clamps Rural building with possibility of setting up stakes Urban building with no possibility of setting up stakes Only with TT system Earth electrode R1 R2 to be tested Rn-1 Rn Schematic diagram: 2-clamp method H S ES RE E C.A 6472 It is also possible to use the 4-pole + clamp method, which requires auxiliary stakes but allows precise measurement of the earth resistance. 362 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > INFO AND ADVICE > SAFETY OF MACHINES SAFETY OF MACHINES, SWITCHBOARDS AND PORTABLE ELECTRICAL APPLIANCES SAFETY OF MACHINES The IEC 60204 / EN 60204 standard defines a machine as a set of parts or systems linked together, at least one of which is mobile. The fields of application are particularly diverse: machines for working metal, wood, textiles, printing, compressors, leather, tanneries, agricultural machinery, building sites and quarries, etc. Part 1 of this reference standard defines the general requirements regarding electrical machine safety to ensure the protection of people who may be exposed to hazardous phenomena due to failure of the electrical equipment or the command circuits, disturbances in the power sources or power circuits, loss of continuity in the circuits, electromagnetic disturbances, release of accumulated energy, excessive audible noise or excessive surface temperatures. To ensure electrical safety on the machines, you have to carry out a number of checks and tests after initial implementation, installation, renovation or modification and during periodic testing. Checking of the protective automatic cut-off systems on the power supply in particular (the types of tests and checks depend on the earthing system): ·Checking of PE continuity on each circuit in the machine with a measurement current 200 mA which may be as high as 10 A, · Verification of the loop impedance as per IEC 61557- 3 and correct coordination of the protection against overcurrents · Visual check of the protection against overcurrents · RCD testing as per IEC 61557-6, tripping-time test (recommended) · Verification of the current at the first insulation fault by measurement or calculation Note: this test may be simplified depending on the condition of the machine as established by a questionnaire included in the standard. Insulation resistance measurement at 500 Vdc, R > 1 M Test of dielectric strength with 50 or 60 Hz AC voltage, at 2 x UN or 1,000 V, duration 1 sec (without disruptive discharge) Residual overvoltage test by measuring the discharge time < 1 sec or 5 sec. O perating test of the machine and the circuits involved in electrical safety The tests are usually performed in the order of decreasing failure in order to intercept electrical safety problems on the machine tested as quickly as possible. Other aspects of the machine may be checked, such as the conformity of the documentation, the temperature reached, the correct order of the phase sequence and the phase drop between the power supply and the load. SWITCHBOARD SAFETY A recent upgrade of this standard precisely defines the limits of liability between the original manufacturer, who should perform the design checks, and the assembler (switchboard operator) who should perform individual series testing. These checks include construction and performance tests. The switchboard operator is considered to become the original manufacturer if modifications are made to the low-voltage switchboard. A declaration of conformity based on simple comparison with a similar switchboard will not be accepted, so a new check is necessary. This new context means that additional test equipment is needed to ensure compliance with the requirements of this reference standard. The tests required for low-voltage switchboards are: Physical measurement of the insulation gap or leakage distance PE continuity check with a measurement current 200 mA which may be up to 10 A (R 0.1 ) Short-circuit withstand by creating a bolted short- circuit C hecking of the dielectric properties by a test at 50 / 60 Hz with the application of a voltage between the different groups of terminals rising slowly and then held for 5 sec or 1 sec Insulation test (variant) Other aspects can also be checked, such as the discharge time, the IP protection rating, the electrical circuits and connections (by random testing), identification of the external terminals, mechanical operation, shock voltage withstand, heating, etc. SAFETY OF PORTABLE ELECTRICAL APPLIANCES The VDE 701 and VDE 702 standards define the inspections to be performed after repair or modification of the electrical appliances and the periodic inspections necessary, as well as general guidelines for electrical safety. This reference standard describes the automatic sequencing of the tests to be performed. Many of the tests and checks to be performed are identical to those described in the Machines and Switchboards section, plus certain tests "with probes" when the equipment does not have double insulation or reinforced insulation (Class I). Furthermore, the leakage current measurements must include leakage measurements by different methods (substitution method, differential leakage method, contact leakage method, etc.). The polarity of the mains leads must also be checked to ensure that it complies. MAIN TESTS & CHECKS (IEC 61557-4) TESTER I-MEASUREMENT PE CONTINUITY TEST PE N L1 L2 L3 Used to check whether the resistance measured corresponds to the cross-section and length of the PE conductor. HV DIELECTRIC TEST AC dielectric strength HV probe TESTER PE N Vac Test L1 L2 L3 The AC dielectric test can be used to confirm the device's ability to function at its operating voltage. These tests are performed at a higher voltage than the normal operating voltage. INSULATION RESISTANCE MEASUREMENT Measurement of Rinsulation in M (IEC 61557-2) HV probe PE TESTER N Vdc Test L1 L2 L3 By measuring the insulation resistance, it is possible to detect faults due to deterioration or pollution and mould. RCD AND PRCD TEST RCD test (Uc, T, I) (IEC 61557-6) TESTER PE Three-point N connection L1 L2 L3 The RCD test can be used to check operation of the RCDs. LOOP IMPEDANCE MEASUREMENT Loop & PFC measurement (IEC 61557-3) TESTER PE Three-point N connection L1 L2 L3 By measuring the loop impedance and calculating the prospective fault current (PFC), you can check that the automatic cut-off systems or fuses are appropriately sized. DISCHARGE TIME Disconnection TESTER PE Three-point N connection L1 L2 L3 When the machines are disconnected, high-value capacitors may supply a hazardous voltage. This test measures whether the time taken by the discharge voltage to reach a non-hazardous value complies with the requirements (< 5s / < 1s). TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 337 ELECTRICAL SAFETY > INFO AND ADVICE > TECHNICAL OVERVIEW / OTHER TESTERS TECHNICAL OVERVIEW / OTHER TESTERS LOW RESISTANCE MEASUREMENT The measurement of low resistances is widely used in preventive maintenance to check the continuity of the chassis-earths, surface condition and metallization, the quality of the contacts in the switches and relays, the resistance of the cables and windings, to assess motor and transformer heating and, in general, to check the mechanical joints. A wide variety of fields are involved, including the automotive sector, telecommunications, transport, motor and transformer manufacturers, etc. as well as the repair and maintenance companies working in these different sectors. Measurement principle The basic principle for measuring resistance involves applying Ohm's Law: U = R x I. Where: Ri = internal resistance of the instrument, Rf = resistance of the measurement wires Rc = contact resistance Rx = resistance to be measured When measuring very low resistances, a measurement current is injected and the resulting voltage is measured on the terminals of the resistance to be checked. The connections are the same as for 4-wire measurements, often called a Kelvin assembly, which limits the influence of the measurement leads when measuring low resistances. The connection diagram is shown opposite: From a DC voltage source U, a generator supplies a current with the value I. A voltmeter measures the voltage drop Ux at the terminals of the resistor Rx to be measured and displays Rx = Ux / I. The result is independent of the other resistances encountered in the current loop (Ri, Rf, Rc), as long as the total voltage drop which they cause with Rx remains lower than the voltage which the current source can supply. In practice, double retractable test probes, pivoting or otherwise, or Kelvin clamps are used for better contact with the object to be tested. Lastly, when measuring on a rivet, the two contacts of a given test probe must be capable of retracting by different amounts. The micro-ohmmeters must offer a resolution of 1 or even 0.1 , a wide measurement range and compensation of the thermocouple effects by inversion of the measurement current. To ensure operator safety, the equipment must be protected against accidental overvoltages, prevent measurement in the presence of a disturbance voltage and trigger automatic discharging after measurements on inductive objects. Lastly, as the resistance of metals changes significantly according to the temperature, it is a good idea to present the result at a given reference temperature. The instruments with the best performance automatically perform this calculation according to the type of metal, its temperature coefficient (approximately 0.4 % / °C for copper or aluminium), the ambient temperature and the reference temperature. MEASUREMENT OF THE TRANSFORMER RATIO AND EXCITATION CURRENT Strict compliance with the primary / secondary ratio values of the voltage, power and current transformer is crucial because any variation of these values over time is a sign of problems in the transformer, such as internal damage, possible deterioration of the insulants due to mechanical damage or contamination or short-circuits between loops. In addition, accurate measurement of the excitation current can identify problems in the magnetic core of the transformer, such as type and thickness of the material, mechanical stresses and air-gap and assembly variations. By checking the winding polarity and the presence of open circuits or groups of terminals in open circuit, it is possible to detect rewiring errors after maintenance operations. Transformer ratio measurements performed using the method described in the IEEE C57.12-90TM- 2006 reference document ensure standard, repeatable measurements. As such measurements are often performed in environments where a lot of noise is present, it is important for the operator to be able to choose different filters in order to obtain more reliable results in such environments. Operator safety is ensured by a technique involving primary excitation, thus guaranteeing that no hazardous signal can occur at the secondary terminals of the transformer being tested. Storage of different "boilerplates" (specifications) in the instrument and direct display of the ratio value and its percentage deviation from the rated value help to speed up interpretation of the measurements performed. Their long battery life and their storage capacity for the results make digital ratiometers particularly useful for performing and analysing measurements. MOTOR DIRECTION AND PHASE ROTATION TESTS Interconnection of several sections of the electrical network or several buildings on the same site in a threephase system requires the phase sequence to follow the normal direction. This is particularly crucial for the power supplies of rotating machines as the rotation order of the phases connected determines the direction of the rotating field and therefore the rotation direction of the rotor. Phase rotation direction The phase rotation direction can be determined by connecting the three phases of the electrical network to be tested to the tester, in accordance with the markings. The tester then indicates the phase rotation direction: clockwise or anticlockwise. In this case, the tester is selfpowered via the measurement inputs. To cover a wide range of applications, the equipment must be capable of operating at frequencies from 15 to 400Hz. Rotating field direction or rotation direction without connection For some phase sequence detectors, the possibility of testing without connection, simply by positioning the tester on the casing of the motor, allows you to obtain a quick indication of the rotating field direction. In this mode, the tester must be set up in parallel to the rotor and in the prescribed direction. This principle is not valid when controlling a motor by means of a frequency converter. Determination of the phase connection direction on a motor If you connect the motor's power supply phases to the tester and turn the rotor half a turn to the right by hand, the tester indicates whether or not the phase wires are connected in the right order. Indication of solenoid valve activation without connection On testers capable of testing without connection, the activation of a solenoid valve can be detected by placing the tester close to the valve. The clockwise or anticlockwise LED then indicates the direction of the field generated. BATTERY CAPACITY MEASUREMENT Research carried out by battery manufacturers has shown that the internal impedance of a rechargeable battery increases with its age and the number of discharges which it has undergone. By analysing the internal impedance, you can therefore assess the condition of the elements inside and determine whether the battery needs to be replaced or not. Instead of the absolute value of the battery's internal resistance, it is the variation of the value which is important. Indeed, a 25% increase causes performance to fall by approximately 80%. These values may vary according to the battery technology involved. These values are compared with the instantaneous measurements made and noted when the batteries were installed. Preventive maintenance equipment should simultaneously measure and display the internal resistance by means of a 4-wire method for AC at a frequency close to 1 kHz, as well as the open-circuit voltage. As the internal resistance values measured may be low, you have to compensate the resistance of the measurement leads and retractable test probes. A large number of alarm comparison systems are used to quickly detect battery deterioration. On the basis of this comparison, the result is assessed and one of the LEDs (PASS, WARNING, FAIL) is then activated accordingly. 382 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > INSTALLATION TESTERS > SELECTION GUIDE CHOOSE YOUR INSTALLATION TESTER CA 6113 page 40 CA 6116N page 40 CA 6117 page 40 Insulation Test voltage RCD tests No-Trip tests Trip time (pulse) Trip current (Ramp) Management of standard or selective RCDs, type AC or A Management of type-B RCDs Earth measurement 2P / 3P earth 1P live earth (RA) Selective earth with 1 clamp (RA Sel) Loop impedance & resistance Z-loop (L-PE) Z-Line (L-N or LL) Ik calculation (PFC) Icc calculation (PSCC) Integrated fuse table Voltage drop Resistance / Continuity Manual & automatic measurements Other functions Voltage / frequency Current / leakage current on clamp Phase sequence Power values Harmonics Wiring polarity test + reversal Alarms Data Storage / Communication Data storage Storage of 3 tree-structure levels USB interface Bluetooth Display and power supply Black and white LCD Black and white graphical LCD Colour graphical LCD Online help Battery operation Operation with rechargeable batteries Software ICT / DataView® Android application Safety / Standards IEC 61010-1 600 V CAT III IEC 61557 50 / 100 / 250 / 1,000 V Ni-Mh Li-ion Li-ion CA 6011 page 43 CA 6131 page 42 CA 6133 page 42 250 / 500 V 250 / 500 / 1,000 V (standard) (standard) / - / (Two-colour backlighting) (Custom) (Custom) Ni-Mh TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 339 ELECTRICAL SAFETY > INSTALLATION TESTERS > CA 6113 - CA 6116N - CA 6117 CA 6113 - CA 6116N - CA 6117 REF.: P01145445 REF.: P01145455 REF.: P01145460 600 V IP CAT III 53 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Tests on RCDs (types AC, A and B) · Battery life of up to 30 hours · Testing according to IEC 60364-6, NF C 15-100, VDE 100, FD C 16-600... · Automatic continuity measurement · Colour screen (except CA 6113) · Measurements: voltage, current via clamp, power, waveforms and harmonics · Loop measurement with 1 m resolution CONTENTS CA 6113 delivered in a shoulder bag with: · 1 x PA 30 W power pack · 1 Euro 3-point lead - 3 safety leads (red, blue, green) · 3 test probes Ø 4 mm (red, blue, green) · 3 crocodile clips (red, blue, green) · 2 elbowed-straight safety leads (red and black) 3 m long · 1 three-point Euro mains lead · 1 remote-control probe · 1 anti-scratch film mounted on the instrument · 1 wrist-strap · 1 x 4-point hands-free strap · 1 CD-ROM containing the user's manual CA 6116N and CA 6117 delivered in a shoulder bag with: · 1 mains power / charger pack (type 2) · 1 Li-Ion rechargeable battery pack mounted on the instrument · 1 USB A / B cable 1.80 m long with ferrite · 1 three-point lead - 3 safety leads (red, green and blue) · 3 test probes Ø 4 mm (red, green and blue) · 3 crocodile clips (red, green and blue) · 2 elbowed-straight safety leads 3 m long (red and black) · 1 three-point EURO mains lead · 1 two-point EURO mains lead · 1 remote-control probe · 1 anti-scratch film mounted on the instrument · 1 wrist-strap · 1 x 4-point hands-free strap · ICT data export software on CD-ROM · 1 CD-ROM containing the user manual ACCESSORIES / REPLACEMENT PARTS Three-point lead with separated wires 2.5 m Three-point lead for testing European mains sockets See all the accessories on page 81 P01295398 P01295393 ADDITIONAL INFO · Integrated fuse table for quick result readings on the instrument · User-friendly interface · Extra-wide graphical screen · Integrated contextual help for each function · ICT data export software provided · Compatible with the DataView® software · Delivered as standard with a three-point European mains lead EFFECTIVE CONTEXTUAL HELP AND GUARANTEED SAFETY These testers are equipped with clear, detailed contextual help. This makes them suitable for both experts and less-experienced users. There is dedicated help for each measurement, including a guide to the connections to be set up and help for interpreting the results. For greater safety, if it is incorrectly connected or if a hazardous voltage is present, the instrument displays an error message in order to warn the user. 402 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > INSTALLATION TESTERS > CA 6113 - CA 6116N - CA 6117 CA 6113 CA 6116N CA 6117 Continuity / Resistance Measurement current I > 200 mA up to 39.99 and approx. 12 mA up to 400 Accuracy ± (1.5% of measurement + 2 cts), with audible beep Range 4 k / 40 k - 400 k Insulation Test voltage 50 / 100 / 250 / 500 / 1,000 Vdc Range / accuracy 0.01 M to 2 G / ±(5 % of measurement + 3 cts) Short-circuit current 3 mA Earth 3P earth Range 0.50 to 15 k Accuracy ±(2 % of measurement + 2 cts ) Others RH & RS auxiliary-stake resistance measurement (up to 40 k) Selective 1P earth Range / accuracy 0.20 to 399.9 ±(10 % of measurement + 10 cts) (ISel via clamp) Loop impedance (Zs (L-PE) and Zi (L-N or L-L)) 1P live earth Live earth Installation voltage / freq. High current mode - Zs (L-PE) (TRIP) & Zi (L-N or L-L) Range / accuracy NO TRIP mode (Zs (L-PE)) Calculation of short-circuit current Ik (PFC (Zs)) , I Sc (PSCC (Zi)) 90 to 500 V / 15.8 to 17.5 Hz - 45 to 65 Hz Max. test current: 7.5 A 0.100 to 399.99 / ±(5% of measurement + 2 cts) Test current: 6 mA 9 mA 12 mA (as required) - 0.20 to 3,999 ±(5% of measurement + 2 cts) Fault and short-circuit current: display range 0.1 A to 6 kA Integrated fuse table Yes Voltage drop DU% (Zi) -40% to + 40% Others Measurement of the resistive and inductive components of the impedances Zs and Zi RCDs Type AC and A RCDs Installation voltage / freq. IDn 90 to 500 V / 15.8 to 17.5 Hz - 45 to 65 Hz 10 / 30 / 100 / 300 / 500 / 650 / 1,000 mA (90 V 280 V) or variable - 10 / 30 / 100 / 300 / 500 mA (280-550 V) or variable Ramp and pulse test Type B RCDs NO TRIP test Trip current Ramp mode Trip time measurement Pulse mode Installation voltage / freq. IDn: ramp / pulse 2 x IDn pulse 4 x IDn Test in ramp mode at ½ IDn Duration: 1,000 ms or 2,000 ms 0.3 x IDn to 1.06 x IDn in increments of 3.3% x IDn 0.2 to 0.5 x IDn (Uf) / 0.5 x IDn / 2 x IDn (selective) / 5 x IDn. Pulse: 0 to 500 ms, Ramp mode: 0 to 200 ms 90 V to 275 V / 15.8 to 17.5 Hz - 45 to 65 Hz 10 / 30 / 100 / 300 / 500 mA 10 / 30 / 100 mA 0.2 x IDn to 2.2 x IDn Trip test 1.1x2 or 2.2x2 or 2.2x4 x IDn Other measurements Current (1 mA*) 5.0 mA to 19.99 A (MN77 clamp) / 5.0 mA to 199.9 A (C177 A clamp) Voltage 0 to 550 Vac / dc / dc and 15.8 to 500 Hz Frequency 10 to 500 Hz Phase rotation Active power Harmonics 20 to 500 Vac 0 to 110 kW in single-phase - 0 to 330 kW in three-phase Simultaneous display of voltage and current waveform Voltage and current / up to 50th order / THD-F / THD-R General specifications Large backlit LCD screen, 320 x 240 cts monochrome graphical 5.7`' colour graphical 5.7'' Data storage / Communication 1,000 tests / via USB for data transfer and report generation Power supply: rechargeable battery NiMH 9.6 V rated 4 Ah. Lithium-ion 10.8 V rated 5.8 Ah Battery life up to 24 hours up to 30 hours Dimensions / weight 280 x 190 x 128 mm / 2.2 kg Ingress protection / EMC IP 53 / IK04 / IEC 61326-1 Electrical safety / Standards IEC 61010 -1 600 V CAT III 300 V CAT IV IEC 61557 *if a voltage is connected to the instrument TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 341 ELECTRICAL SAFETY > INSTALLATION TESTERS > CA 6131 - CA 6133 CA 6131 - CA 6133 REF.: P01146011 REF.: P01146013 600 V IP CAT III 54 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Earth measurement by stake and loop method · Continuity measurement at 0.2 A · Insulation testing · RCD testing: current and trip time · Automatic test sequences · Storage of tests · Power supply by mains-rechargeable batteries with USB or vehicle cigarette lighter connection ADDITIONAL INFO · The Android IT-Report software is available to transfer the test results from the CA 6133 and generate reports. · Find all our applications at https: / / play.google.com by typing Chauvin Arnoux in the search bar. CONTENTS CA 6131 and CA 6133 delivered with 1 carrying bag containing: · 1 neck strap · 1 three-pole EURO mains cable · 3 safety cables · 3 crocodile clips · 1 test probe · 1 USB 2 A power supply + 1 USB cable (CA 6133) · 6 x 1.5 V LR06 batteries (CA 6131) · 6 Ni MH rechargeable batteries (CA 6133) · 1 test report with measurement report ACCESSORIES / REPLACEMENT PARTS Remote-control probe MN73A current clamp (for CA 6133) See all the accessories on page 81 P01102157 P01120439 Auto Script SPECIFICATIONS Continuity Range / Resolution / Accuracy Resistance Range / Resolution / Accuracy Insulation Test voltage Range / Resolution / Accuracy Earth resistance - 3P method CA 6131 CA 6133 0.00 to 9.99 / Cable compensation up to 5 ; I >= 200 mA / 0.01 / ± (2 %R + 2 cts) 1 to 9,999 -- 10.00 to 99.99 k / 1 -- 10 / ± (1 %R + 5 cts) 250 V / 500 V 250 V / 500 V / 1,000 V 0.01 to 999.9 M / 10 k or 100 k / ± (3 %R + 3 cts) Range - 0.50 to 100.0 to 1,000 to 99.99 999.9 2,000 Resolution - 0.01 0.1 1 Accuracy - ±(2 %R + ±(2 %R ±(2 %R 10 cts) + 5 cts) + 5 cts) Measurement frequency - 128 Hz Earth loop measurement (Zs) NO TRIP (12 mA) Range / Resolution / Accuracy 1 to 2,000 / 1 / ± (5 %R +2 cts) Ik calculation 1 to 999 A With TRIP(300 mA) Range / Resolution / Accuracy 0.1 to 399.9 / 0.1 / ±(5 %R + 2 cts) Ik calculation 1 to 9,999 A Fault loop measurement (Zi) Type of connection Banana leads Range / Resolution / Accuracy Measurement current 300 mA; 0.1 to 399.9 / 0.1 / ± (5 %R + 2 cts) Ik calculation 1 to 9,999 A RCD test Installation voltage 90 to 450 V ; 45 to 65 Hz Types and calibres AC and A ; 30 mA - 100 mA - 300 mA - 500 mA - 650 mA Trip time 0.5 x IDN; 1 x IDN; 5 x IDN / 5.0 to 300 ms Trip current 30 mA : -0 .. +(7 %R +3.3 % IDN + 2 mA) Fault voltage: Range / 1.0 to 25.0 V -- 25.0 to 70.0 V / 0.1 V / ± (15 %R + 3 cts) Resolution / Accuracy -- ± (5 %R + 2 cts) Automatic test sequence No RCD, Loop-RCD-Insulation Voltage & frequency Voltage: Range / Resolution / Accuracy 2.0 to 550.0 Vac / 0.1 V / ± (1 %R+2 cts) ; 0.0 to 800.0 Vdc / 0.1 V / ± (1 %R+2 cts) Frequency: Range / Resolution / Accuracy - 30.0 to 999.9 Hz / 0.1 Hz / ±(0.1 %R + 1 ct) - Voltage > 2 V Phase rotation 45 to 550 V / 45 to 65 Hz Current Via clamp with voltage output Via MN73 A clamp, 2 A using the voltage sensor calibre: 10.0 mA to 2,400 mA, option (AUX) 200 A calibre: 1.00 to 200 A AUX sensor function (CA 6131) AC+DC range: Range / Resolution / Accuracy 2.0 to 999.9 mV -- 1.000 to 1.2000 V / 0.1 mV -- 1 mV / ±(1 % R + 2 cts) - DC range / Resolution / Accuracy ±(0.0 to 999.9 mV) -- ±(1.000 to 2.000 V) / 0.1 mV -- 1 mV / ±(1 % R + 2 cts) - General specifications Display 231-segment LCD with blue backlighting Data storage - 30 sites x 99 tests Communication - Bluetooth Class 1 ; range 10 m Software - IT-Report Android application Power supply 6 x LR 6 or AA batteries 6 NiMH batteries rechargeable via the mains < 6 hours, USB or vehicle cigarette lighter Battery life > 1,900 continuity measurements at 1 > 1,700 continuity measurements at 1 Dimensions / weight 223 x 126 x 70 mm / Approx. 1.1 kg Environment Operation: 0 to 40 °C / Storage: - 10 to 70 °C (RH 80%) Protection IP 54 (IEC 60 529); IK 04 (IEC 50102) Standards / electrical safety EMC: IEC 61326-1 ; IEC 61010-1 ; IEC 61010-2-030 ; IEC 61010-2-034, 600 V CAT III, 300 V CAT II on charger input IEC 61557 compliance Parts 1, 2, 3, 4, 6, 7 and 10 Parts 1, 2, 3, 4, 5, 6, 7 and 10 422 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > INSTALLATION TESTERS > CA 6011 CA 6011 - CA 6011 KIT 40 REF.: P01191611 REF.: P01299926 300 V IP CAT IV Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology IEC 61557-4 STRENGTHS · Dedicated to continuity testing on protective earth conductors · Double configuration: continuity tester attached to the reeler and remote continuity tester on the wrist · Lightweight and compact · Ergonomic to facilitate operators' work ADDITIONAL INFO · Triple visual indications: - Backlighting (blue / red) - Symbols: "Confirmed box" / "X-barred box" - Measurement value · Buzzer · Vibrator CONTENTS CA 6011 KIT delivered with: · 1 elastic strap for fixing the measuring unit to your wrist · 1 waist belt + 1 shoulder belt · 1 "Cable Reeler No. 01" with 1 green PVC cable 30 m long · 1 black spiral PVC cable 3.5 m long · 1 green crocodile clip with Ø 4 mm banana socket · 1 moulded black test probe · 1 green PVC cable 0.50 m long · 1 set of 4 x 1.5 V LR06 alkaline batteries CA 6011 delivered with: · 1 elastic strap for fixing the measuring unit to your wrist · 1 set of 4 x 1.5 V LR06 alkaline batteries SPECIFICATIONS Display Continuity Measurement range Resolution Measurement current Open-circuit voltage Resistance Measurement range Resolution Measurement current Open-circuit voltage Continuity threshold Compensation of cable resistance Test conformity / nonconformity indication Compliance with standards Automatic standby mode Battery life Power supply Dimensions (instrument+reeler) Weight CA 6011 CA 6011 KIT 2,000 counts with two-colour backlighting 0.00 to 2.00 2.00 to 20.00 10 m 200 mA 20 mA with automatic polarity reversal ±(4 Vdc < U < 6 Vdc) 1.0 to 200.0 100 m 10 mA ±(4 Vdc < U < 6 Vdc) Programmable: 1 or 2 Yes Configurable: visual, audible and / or vibrating IEC 61557-1 & IEC 61557-4 IEC 61010-1, IEC 61010-2-030 300 V CAT IV 10 minutes / deactivatable 30,000 measurements in actual use 4,500 as per IEC 61557-4 protocol 4 x 1.5 V AA / LR6 batteries 225 x 185 x 135 mm CA 6011 alone: 350 g Reeler with 30 m cable: 1.2 kg ACCESSORIES / REPLACEMENT PARTS Cable reeler no.1 30 m Continuity rod See all the accessories on page 81 P01295492 P01102084A TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 343 ELECTRICAL SAFETY > TEST ADAPTER > CA 6651 CA 6651 REF.: P01191306 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology TEST ADAPTER FOR ELECTRIC VEHICLE AC CHARGING STATIONS STRENGTHS · Adapter for interfacing on the sockets of mode-3 AC vehicle charging stations equipped with a type-2 cable to test the safety and operation of the charging station by means of an installation tester · Simulation of the presence of an electric vehicle in its various states (CP signal) : A disconnected / B connected / C charging without ventilation / D charging without ventilation · PE pre-test: safety function to check that no hazardous voltage is present in relation to the protective earth PE · Indication of the presence of phases L1 / L2 / L3 by 3 LEDs · Verification of the Proximity Pilot (PP) signal to simulate the different charging currents: 13 A / 20 A / 32 A / 63 A with selection by rotary switch SPECIFICATIONS CA 6651 TECHNICAL SPECIFICATIONS PE pre-test Yes with touch electrode PP simulation Open NC, 13 A , 20 A, 32 A, 63 A CP status A, B, C, D CP / PE error 3 buttons on side for error simulation; CP/PE or diode short-circuit and opening of PE Earth fault PE error PP switch set to NC Protection / Acceptable overload 600 Vrms Outputs L1 / L2 / L3 / N and PE measurement terminals 230 V single-phase and 400 V three-phase 50Hz Mains socket Max 250 V Cat II 300 V Admissible current: 10 A (fuse) CP signal terminal PWM + / -12 V communication protocol Specifications Input voltage 230 V / 400 Vac 50 / 60Hz 10 A Charging station socket connector Charging mode 3 adapted to IEC 62196-2 type 2 socket or fixed cable with connector for type 2 vehicle, three-phase Power socket protection Internal fuse: T 10 A / 250 V Measurement compatibility with CA 6117 installation tester Earth loop measurement, 30 mA type-B RCD test (from 6 mA), insulation test at 500 V and continuity test report HANDSCOPE oscilloscope Display of PMW waveform between CP and PE LEDs EV standards Safety IP / IK Connection socket Dimensions / weight TECHNICAL SPECIFICATIONS X3, blue IEC 61851-1 / IEC 60364-7-722 EN61010-1, pollution degree 2, CATII-300 V IP 20 as per IEC60529 Type 2 32 A 3PH+N+PE type E2201 200 / 346 V Casing dimensions: 174x43x43 mm / Weight: 850 g ADDITIONAL INFO Adapter alone · Verification of the signals present on the type 2 socket and PE pre-test · Simulation of vehicle status ( battery ready to charge, with or without ventilation) · Simulation of the PP current to check the status of the charging status Adapter with CA 6117 · Electrical safety tests · Connection on 5 sockets, diam. 4 mm, identified as L1 / L2 / L3 / N / PE for connecting the installation tester equipped with banana plugs · Mains socket offering the possibility of connected the installation tester's 2P+E plug: Schuko socket with 2 metal studs CONTENTS CA 6651 delivered with 1 carrying bag containing: · 1 cable equipped with a type-2 socket ACCESSORIES / REPLACEMENT PARTS Carrying bag P01298078 442 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > PORTABLE INSTALLATION TESTERS > SELECTION GUIDE CHOOSE YOUR PORTABLE INSULATION TESTER CA 6501 CA 6503 CA 6511 CA 6513 CA 6528 CA 6522 CA 6524 CA 6526 CA 6532 CA 6534 CA 6536 Type Test voltage (in Vdc) page 46 page 46 Hand-cranked 10 25 50 100 250 500 1000 Max. measured value 200 M 1 G 5 G 11 G 20 G 40 G 50 G 200 G Continuity Resistance Capacitance Leakage current Chronometer Programming of test duration Quality ratios PI DAR Graphics Data storage Bluetooth Display Analogue LCD LCD + bargraph Power supply Hand-cranked magneto Batteries page 46 page 46 page 47 Analogue page 48 page 48 page 48 page 49 Portable digital page 49 page 49 1 V increments 1 V increments 1 V increments 1 V increments TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 345 ELECTRICAL SAFETY > INSULATION TESTERS > CA 6501 - CA 6503 | CA 6511 - CA 6513 CCHAO6I5S0IR1 REF.: P01132503 -SCROEFA.:NP01163C2550O40N3 TRÔC3A0T0LIVIIEU5IP4R D'CISAO6L5E1M1 -ECNAT P65O1R3TATICF6A0T0IVII REF.: P01140201 REF.: P01140301 IP 40 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology HAND-CRANKED INSULATION TESTERS Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology ANALOGUE INSULATION TESTERS STRENGTHS · Rugged plastic casing ideal for all-terrain use · Special for on-site use · Does not require a power supply SPECIFICATIONS Insulation Test voltage (DC) Range Accuracy Resistance Range Accuracy Continuity Range Accuracy Voltage Range Frequency Accuracy Display Dimensions / weight Power supply Ingress protection Electrical safety CA 6501 500 V 0.5 to 200 M 2.5 % of full scale 45 to 500 k 2.5 % of full scale CA 6503 250 V / 500 V / 1,000 V 1 to 5,000 M 2.5 % of full scale - 0 to 100 - 2.5 % of full scale 0... 600 Vac 45 to 450 Hz 3 % of full scale Analogue 120 x 120 x 130 mm / 1.06 kg Hand-cranked magneto providing a stable voltage IP 54 with cover / IP 52 without cover IEC 61010 - 600 V CAT II / 300 V CAT III CONTENTS CA 6501 delivered in a shoulder bag · 2 elbowed / straight PVC leads 1.5 m long (black / red) · 2 crocodile clips (black / red) · 1 black test probe CA 6503 delivered in a shoulder bag · 3 elbowed / straight PV leads 1.5 m long (black / red / blue) · 3 crocodile clips (black / red / blue) · 1 black test probe STRENGTHS · Simple to use · Rugged thanks to their shockproof sheath SPECIFICATIONS Insulation Test voltage (DC) Range Accuracy Resistance Range Accuracy Continuity Range Accuracy Measurement current Current reversal Voltage Range Frequency Accuracy Display Dimensions / weight Power supply Electrical safety CA 6511 CA 6513 500 V 500 V / 1,000 V 0.1 to 1,000 M ± 5 % of measurement - 0 to 1,000 - ± 3 % of full scale -10 to +10 ± 3 % of full scale 200 mA Yes 0... 600 Vac 45 to 400 Hz 3 % of full scale Analogue 167 x 106 x 55 mm / 500 g (excluding sheath) 4 x 1.5 V LR06 batteries IEC 61010 - 600 V CAT III ADDITIONAL INFO · CA 6511 : insulation at 500 V, continuity at 200 mA · CA 6513 : insulation at 1,000 V, continuity at 200 mA and resistance CONTENTS CA 6511 and CA 6513 delivered mounted in their shockproof sleeves · 2 elbowed / straight PVC leads 1.5 m long (black / red) · 1 black test probe · 1 red crocodile clip · 4 x 1.5 V LR06 batteries · 1 replacement fuse ACCESSORIES / REPLACEMENT PARTS Bag no. 2 CA 1246 thermo-hygrometer See all the accessories on page 81 P01298006 P01654246 ACCESSORIES / REPLACEMENT PARTS CA 1821 thermometer CA 1246 thermo-hygrometer See all the accessories on page 81 P01654821 P01654246 462 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > DIGITAL INSULATION TESTERS > CA 6528 CA 6528 40 REF.: P01140838 1000 V 600 V IP CAT III CAT IV Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Insulation measurement at 250 / 500 / 1,000 V · Insulation resistance up to 11 G · Manual, locked and timer modes · AC and AC+DC voltage measurement up to 700 V · Continuity at 200 mA · Visual alarm, blue / red backlighting CONTENTS CA 6528 delivered in hands-free bag containing: · 2 safety leads (1 red, 1 black) · 1 red crocodile clip · 1 black test probe · 1 protective sheath mounted on the instrument · 6 x LR6 or AA batteries · 1 safety datasheet · 1 Quick Start Guide · 1 verification certificate SPECIFICATIONS CA 6528 Industrial maintenance Voltage Measurement range / resolution 1-700 V / 1 V Accuracy / input impedance ±1.2% R ± 1ct for AC+DC; ±1 R ± 1ct for DC / 25 M Operating frequency DC ; 45-65 Hz Insulation Test voltage 250-500-1,000 V Range at maximum test voltage 11 G Measurement range 250 V 50 k - 4.2 G 500 V 100 k - 4.2 G 1 000 V 200 k - 11 G 50 k - 3.999 / 1 k; (0.2)1, 3.6-39.99 M / Measurement range / resolution 10 k; 3.6-399.9 M / 100 k; 360-4,200 M / 1 M; (1 kV) 3.6 - 11.00 G / 10 M Accuracy 0.05-399.9 M : ±1.5 R ± 10 cts; 360 -4,200 M: ±4 R ± 10 cts ; ±4 R ± 5 cts (at 1,000 V); 3.6-11 G: ±10 R ± 10 cts Timer (min:s) 10s to 39min 59s Alarms 1 threshold / test voltage Continuity Measurement range 0.02 - 40 (200 mA) Accuracy / open-circuit voltage ±1.2% R ±3 cts / 6 Vdc < U < 9 Vdc Measurement current 200 mA (up to 2 ) Continuity threshold (fast beep) 2 / 1 Cable compensation up to 5 Resistance Measurement range / resolution 1 -399.9 / 0.1 ; 360-3,999 / 1 ; 3.6039.99 k / 10 ; 36.0-420.0 k / 100 Accuracy ±1.2% R ±3 cts General specifications Display 2 x 4,000 cts Power supply / Automatic power-off 6 x LR 6 or AA batteries / 10 min deactivatable Battery life 1,000 measurements: at 1 M @ 1 kV (5 s ON / 25 s OFF); >3,000 continuity measurements (5 s ON / 25 s OFF) at 1 Dimensions / weight / IP rating 218 x 95 x 63 mm / 760 g / IP 40 EMC / electrical safety Compliance with standards IEC 61326-1 / IEC 61010-1, IEC 61010-2-030 and IEC 61010-2-034 / 600 V CAT IV IEC 61557 parties 1, 2, 4 and 10 1 at 1,000 V ACCESSORIES / REPLACEMENT PARTS Set of red and black safety leads 1.5 m Red + black crocodile clips Red + black test probes Continuity rod See all the accessories on page 81 P01295289Z P01295457Z P01295454Z P01102084A TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 347 ELECTRICAL SAFETY > DIGITAL INSTALLATION TESTERS > CA 6522 - CA 6524 - CA 6526 CA 6522 - CA 6524 - CA 6526 REF.: P01140822 REF.: P01140824 REF.: P01140826 54 600 V IP IEC CAT IV 61557 TRMS Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Test voltage from 50 to 1,000 V · Measurement range from 10 k to 200 G · PI and DAR ratios to determine the quality of the insulation · Alarms and Pass / Fail indicator LEDs (CA 6526) · Storage of up to 1,300 measurements CONTENTS CA 6522, CA 6524 or CA 6526 · 1 "hands-free" bag · 2 elbowed-straight safety leads (red and black) 1.50 m long · 1 red crocodile clip · 1 black test probe · 6 x LR6 batteries · 1 CD-ROM containing the multilingual user manual · 1 safety datasheet in 20 languages In addition, for the CA 6526: 1 CD-ROM containing the Megohmmeter Transfer software ACCESSORIES / REPLACEMENT PARTS Type-3 remote-control probe 2 elbowed-straight safety leads (red and black) 1.50 m long See all the accessories on page 81 P01102092A P01295453Z SPECIFICATIONS CA 6522 CA 6524 CA 6526 Industrial maintenance Voltage Measurement range / Resolution 0.3 V - 399.9 V / 0.1 V ; 400 V - 700 V / 1 V Accuracy / Input impedance Operating frequency ± (3 % + 2 cts) / 400 K DC ; 15.3 - 800 Hz Frequency Measurement range / Resolution / Accuracy - 15.3 Hz - 399.9 Hz / 0.1 Hz / ± (1 % + 2 cts) 400 - 800 Hz / 1 Hz / ± (1 % + 1 ct) Insulation Test voltage Range at maximum test voltage Compliance with IEC 61557 - 2 standard Measurement range: 50 V 100 V 250 V 500 V 1,000 V 250-500-1 ,00 V 40 G 50 k - 10 G 100 k - 20 G 200 k - 40 G 50 - 100 - 250 - 500 1,000 V 200 G 2 G 10 k - 10 G 20 k - 20 G 50 k - 50 G 100 k - 100 G 200 k - 200 G Measurement range / Resolution 10(1) - 999 k and 1.000 - 3.999 M / 1 K ; 4.00 39.99 M / 10 k 40.0 - 399.9 M / 100 K ; 400 - 3,999 M / 1 M 4.00 - 39.99 G / 10 M ; 40.0 - 200 G / 100 M Accuracy ± (3 % + 2 cts)(2) Test voltage (I < 1 mA) - 0 % + 20 % Test voltage display ± (3 % + 3 cts) Test current / resolution - 0.01 A - 39.99 A / 10 nA ; 40.0 - 399.9 A / 100 nA ; 0.400 - 2.000 mA / 1 A Accuracy on test current - ± (10 % + 3 cts) PI / DAR ratio - 10 min / 1 min - 1 min / 30 s Timer (min:s) 0:00 - 39:59 Discharge time (at 25 V) < 2 s / F Alarms - 2 fixed thresholds + 1 programmable threshold Continuity Continuity measurement range 0.00 -10.00 (200 mA) 0.00 - 10.00 (200 mA) 0.0 - 100.0 (20 mA) Accuracy / Open-circuit voltage ± (2 % + 2 cts) / > = 6 V Measurement current Continuity thresholds (fast beep) Cable compensation Resistance 200 mA : 200 mA (- 0 mA +20 mA) - 20 mA: 20 mA ± 5 mA 2 fixed 2 , 1 , programmable threshold up to 9.99 Measurement range / Resolution - 0 - 3999 / 1 4.00 k- 39.99 k / 10 40.0 k- 399.9 k / 100 400 k- 1,000 k / 1 k Capacitance Accuracy Measurement range / Resolution Accuracy General specifications Display Data storage Communication ± (3 % + 2 cts) 0.1 nF - 399.9 nF / 0.1 nF - - 400 nF 3999 nF / 1 nF 4.00 F - 10.0 F / 10 nF - - ± (3 % + 2 cts) 2 x 4,000 cts + logarithmic bargraph - 300 measurements 1,300 measurements - - Bluetooth® Class II Power supply / Auto power-off 6 x LR6 batteries / 5 min, deactivatable Battery life 1,500 measurements: UN x 1 k @ UN (5 s ON / 55 s OFF) 3,000 continuity measurements (5 s ON / 55 s OFF) Dimensions / weight / IP rating 211 x 108 x 60 mm / 850 g / IP 54 / IK 04 EMC / Electrical safety IEC 61326 - 1 / IEC 61010 - 1 and IEC 61010 - 2 - 030, 600 V CAT IV Compliance with standards IEC 61557 parts 1, 2, 4 and 10 (1): 2 k for the CA 6532 - CA 6534 - CA 6536. (2): To be added: 10 V: 1 % per 0.1 G; 25 V: 0.4 % per 0.1 G, 50 V: 2 % per G, 100 V: 1 % per G; 250 V; 0.4 % per G; 500 V: 0.2 % per G; 1,000 V: 0.1 % per G. 482 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > DIGITAL INSULATION TESTERS > CA 6532 - CA 6534 - CA 6536 CA 6532 - CA 6534 - CA 6536 REF.: P01140832 REF.: P01140834 REF.: P01140836 54 600 V IP IEC CAT IV 61557 TRMS Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Test voltage from 50 to 1,000 V · Measurement range from 10 k to 200 G · PI and DAR ratios to determine the quality of the insulation · Alarms and Pass / Fail indicator LEDs (CA 6526) · Storage of up to 1,300 measurements CONTENTS CA 6532, CA 6534 or CA 6536 · 1 "hands-free" bag · 2 elbowed-straight safety leads (red and black) 1.50 m long · 1 red crocodile clip · 1 black test probe · 6 x LR6 batteries · 1 CD-ROM containing the multilingual user manual · 1 safety datasheet in 20 languages · In addition, for the CA 6526: 1 CD-ROM containing the Megohmmeter Transfer software ACCESSORIES / REPLACEMENT PARTS Type-3 remote-control probe 2 elbowed-straight safety leads (red and black) 1.50 m long See all the accessories on page 81 P01102092A P01295453Z SPECIFICATIONS Voltage CA 6532 Telecom. CA 6534 Electronics CA 6536 Avionics, ESD, aerospace, defence Measurement range / Resolution Accuracy / Input impedance Operating frequency 0.3 V - 399.9 V / 0.1 V; 400 V - 700 V / 1 V ± (3 % + 2 cts) / 400 k DC; 15.3 - 800 Hz Frequency 15.3 Hz - 399.9 Hz / Measurement range / 0.1 Hz / ± (1 % + 2 cts) Resolution / Accuracy 400 - 800 Hz / 1 Hz / - - ± (1 % + 1 ct) Insulation Test voltage 50 - 100 V 10-25-100-250- 10 to 100 V 500 V 1 V increments Range at maximum test voltage 20 G 50 G 20 G Compliance with IEC 61557 - 2 standard Measurement range: 10 V 25 V 50 V 100 V 250 V 500 V Variable test voltage 10 k - 10 G 20 k - 20 G 2 G 2 k - 1 G 5 k - 2 G 20 k - 10 G 50 k - 25 G 100 k - 50 G 2 k - 2 G (UN / 5) k to (UN / 5) G 20 k - 20 G 10 to 100 V Measurement range / Resolution 10(1) - 999 K and 1,000 - 3.999 M / 1 K; 4.00 - 39.99 M / 10 K 40.0 - 399.9 M / 100 K; 400 - 3,999 M / 1 M 4.00 - 39.99 G / 10 M; 40.0 - 200 G / 100 M Accuracy ± (3 % + 2 cts)(2) ± (3 % + 2 cts)(3) Test voltage (I < 1 mA) - 0 % + 20 % ± 0.5 V Test voltage display ± (3 % + 3 cts) Test current / resolution Accuracy on test current 0.01 A - 39.99 A / 10 nA ; 40.0 - 399.9 A / 100 nA 0.400 - 2,000 mA / 1 A ± (10 % + 3 cts) PI / DAR ratio 10 min / 1 min 1 min / 30 s - - Timer (min:s) 0:00 - 39:59 Discharge time (at 25 V) < 2 s / F Alarms 2 fixed thresholds + 1 programmable threshold Continuity Continuity measurement range 0,00 - 10,00 (200 mA) ; 0,0 - 100,0 (20 mA) Accuracy / Open-circuit voltage ± (2 % + 2 cts) / > = 6 V Measurement current 200 mA : 200 mA (- 0 mA +20 mA) - 20 mA : 20 mA ± 5 mA Continuity thresholds (fast beep) 2 , 1 , programmable threshold Cable compensation up to 9,99 Resistance Measurement range / Resolution 0 - 3,999 / 1 ; 4.00 k - 39.99 k / 10 / ± (3 % +2 cts) 40.0 k - 399.9 k / 100 400 k - 1,000 k / 1 k / ± (3 % + 2 cts) Capacitance 0.1 nF - 399.9 nF / 0.1 nF Measurement range / 400 nF - 3,999 nF Resolution / 1 nF - - 4.00 F - 10.0 F / 10 nF Accuracy ± (3 % + 2 cts) - - Line length 0 - 100 km - - General specifications Display 2 x 4 000 cts + logarithmic bargraph Data storage 1,300 measurements - Communication Bluetooth® Class II - Power supply / Auto power-off 6 x LR6 batteries / 5 min, deactivatable Battery life Dimensions / weight / IP rating EMC / Electrical safety Compliance with standards 1,500 measurements: UN x 1 k @ UN (5 s ON / 55 s OFF) 3,000 continuity measurements (5 s ON / 55 s OFF) 211 x 108 x 60 mm / 850 g / IP 54 / IK 04 IEC 61326 -1 / IEC 61010 -1 and IEC 61010 - 2 - 030, 600 V CAT IV IEC 61557 parts 1, 2, 4 and 10 (1): 2 k for the CA 6532, CA 6534 and CA 6536. (2): To be added: 10 V: 1 % per 0.1 G; 25 V: 0.4 % per 0.1 G, 50 V: 2 % per G, 100 V: 1 % per G; 250 V: 0.4 % per G; 500 V: 0.2 % per G; 1,000 V: 0.1 % per G. (3): To be added: 10 % / UN per 100 M TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 349 ELECTRICAL SAFETY > ON-SITE INSULATION TESTER > SELECTION GUIDE CHOOSE YOUR ON-SITE INSULATION TESTER CA 6541 CA 6543 CA 6505 CA 6545 CA 6547 CA 6549 CA 6550 CA 6555 page 51 Type Test voltage (in Vdc) 50 100 250 500 1000 2500 5000 variable from 50 to 5,100 10000 variable from 40 to 10,000 15000 variable from 40 to 15 000 Max. measured value 4 T 10 T 25 T 30 T Continuity Resistance Capacitance Leakage current Chronometer Programming of test duration Quality ratios PI DAR DD Graphics R (t) u (t) + i (t) i (u) Ramp Ramp by voltage steps Calculation of R. (Tref) I limit Early break / burn-in Data storage RS 232 USB Display LCD + bargraph Graphics Power supply Batteries Rechargeable battery page 51 page 52 page 52 page 53 On-site digital page 53 page 54 page 54 F65 page 55 Portable 502 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > ON-SITE INSTALLATION TESTERS > CA 6541 - CA 6543 CA 6541 - CA 6543 REF.: P01138901 REF.: P01138902 600 V IP CAT III 53 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Test voltages from 50 V to 1,000 V · Wide measurement range from 2 k to 4 T · Automatic calculation of DAR / PI quality ratios · Communication for CA 6543 CONTENTS CA 6541 delivered with an accessories bag containing: · 1 set of 2 leads 1.5 m long (red / blue) · 1 black guarded lead 1.5 m long · 3 crocodile clips (red / blue / black) · 1 test probe (black) · 8 x LR14 batteries CA 6543 delivered with an accessories bag containing: · 1 set of 2 leads 1.5 m long (red / blue) · 1 black guarded lead 1.5 m long · 3 crocodile clips (red / blue / black) · 1 test probe (black) · 1 power-supply lead 2 m long · 1 communication cable SPECIFICATIONS Insulation Test voltage 50 V 100 V 250 V 500 V 1000 V Accuracy 2 k to 40 G 40 G to 4 T Programming of test duration DAR (1 min. / 30 sec.) PI (10 min. / 1 min.) Customizable PI Voltage test / Safety Voltage alert indicator Test inhibition Smoothing function Continuity Range Measurement current Resistance Range Capacitance Range Data storage - Communication Storage of R(t) Storage of measurements Direct report printing Display Communication port PC software Power supply Dimensions / weight Electrical safety CA 6541 CA 6543 2 k to 200 G 4 k to 400 G 10 k to 1 T 20 k to 2 T 40 k to 4 T ±5 % of value ± 3 cts ±15 % of value ± 10 cts 1 to 59 min. 0.000 to 9.999 0.000 to 9.999 Time customizable from 30 s to 59 min. 0 to 1000 Vac / dc Yes > 25 V Yes > 25 V Yes 0.01 to 39.99 200 mA up to 20 0.01 to 400 k 0.005 to 4.999 F Memory 20 kB 20 measurement results No No Giant LCD + bargraph Memory 128 kB Up to 1,500 measurement results On locally-connected printer, fixed format RS232 DataView® (option) Giant LCD + bargraph 8 x LR14 batteries NiMH rechargeable battery 240 x 185 x 110 mm / 3.4 kg IEC 61010 600 V CAT III IEC 61557 ADDITIONAL INFO · Site-proof casing with highly shock-resistant lid · Delivered with an accessories bag which can be clipped onto the site-proof casing ACCESSORIES / REPLACEMENT PARTS Remote control probe CA 1821 thermometer See all the accessories on page 81 P01101935 P01654821 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 351 ELECTRICAL SAFETY > SITE-PROOF INSULATION TESTERS > CA 6505 - CA 6545 CA 6505 - CA 6545 REF.: P01139714 REF.: P01139711 1000 V 600 V IP 53 CAT III CAT IV Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Fixed and programmable test voltages from 40 V to 5,100 V · Wide measurement range from 30 k to 10 T · Measurement filtering functions · Automatic calculation of DAR / PI / DD quality ratios · Measurement of voltage, capacitance and leakage current CONTENTS CA 6505 - CA 6545 delivered with a shoulder bag containing: · 2 safety leads 3 m long with HV plug and HV crocodile clip (red / blue) · 1 guarded safety lead 3 m long with rear-connection HV plug and HV crocodile clip (black) · 1 cable with rear connection (blue) 0.35 m long · 1 mains power cable 2 m long SPECIFICATIONS Insulation Test voltage 500 V 1000 V 2500 V 5000 V CA 6505 CA 6545 10 k to 2 T 100 k to 4 T 100 k to 10 T 300 k to 10 T Voltage programming Accuracy 1 k to 400 G 400 G to 10 T Programming of test duration DAR (1 min. / 30 sec.) PI (10 min. / 1 min.) Customizable PI DD Voltage test / safety Voltage alert indicator Test inhibition Smoothing function Capacitance Leakage current measurement Data storage Communication Storage of R(t) Storage of measurements Display Power supply Dimensions / weight Electrical safety 40 V to 1,000 V: 10 V increments 1,000 V to 5,100 V: 100 V increments ±5 % of value ± 3 cts ±15 % of value ± 10 cts 1 to 59 min. 0.02 to 50.00 0.02 to 50.00 Time adjustable from 30 s to 59 min. - 0.02 to 50.00 0 to 1000 Vac / dc Yes > 25 V Yes > 25 V Yes Adjustable according to test voltage - Configurable Digital filtering to stabilize the measurements 0.005 to 49.99 F 0.001 nA to 3 mA - 4 kB memory - 20 measurement results Giant LCD + bargraph NiMH rechargeable battery 270 x 250 x 180 mm / 4.3 kg IEC 61010 1000 V CAT III - 600 V CAT IV IEC 61557 ADDITIONAL INFO · Highly shock-resistant site-proof casing · Delivered with a carrying bag ACCESSORIES / REPLACEMENT PARTS CA 1246 thermo-hygrometer CA 1821 thermometer See all the accessories on page 81 P01654246 P01654821 522 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > SITE-PROOF INSULATION TESTERS > CA 6547 - CA 6549 CA 6547 - CA 6549 REF.: P01139712 REF.: P01139713 1000 V 600 V IP 53 CAT III CAT IV Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Fixed and programmable test voltages from 40 V to 5,100 V · Wide measurement range from 30 k to 10 T · Measurement filtering functions · Automatic calculation of DAR / PI / DD quality ratios · Graphical display of R(t) curves (CA 6549) · Resistance calculation at a reference temperature (CA 6549) CONTENTS CA 6547 - C A 6549 delivered with a shoulder bag containing: · 2 safety leads 3 m long with HV plug and HV crocodile clip (red / blue) · 1 guarded safety lead 3 m long with rear-connection HV plug and HV crocodile clip (black) · 1 cable with rear connection (blue) 0.35 m long · 1 mains power cable 2 m long · 1 communication cable SPECIFICATIONS Insulation Test voltage 500 V 1,000 V 2,500 V 5,000 V Voltage programming Test by voltage steps Accuracy 30 k to 40 G 40 G to 10 T Programming of test duration DAR (1 min. / 30 sec.) PI (10 min. / 1 min.) Customizable PI DD Voltage test / safety Voltage alert indicator Test inhibition Smoothing function Capacitance Leakage current measurement Data storage Communication Storage of R(t) Storage of measurements Direct report printing Communication port PC software Display Power supply Dimensions / weight Electrical safety CA 6547 CA 6549 30 k to 2 T 100 k to 4 T 300 k to 10 T 300 k to 10 T 40 V to 1,000 V: 10 V increments 1,000 V to 5,100 V: 100 V increments Programmable value and - duration up to 5 increments, three profiles memorized ±5 % of value ± 3 cts ±15 % of value ± 10 cts 1 to 59 min. 0.02 to 50.00 0.02 to 50.00 Time customizable from 30 s to 59 min. 0.02 to 50.00 0 to 1,000 Vac / dc Yes > 25 V Yes Adjustable according to test voltage Configurable Digital filtering stabilizing the measurements 0.005 to 49.99 F 0.001 nA to 3 mA Storage 128 kB Display on screen + Storage of samples Up to 1,500 measurement results On locally-connected printer, fixed format Dump of measurements onto PC USB DataView® (option) Giant LCD + bargraph Wide graphical screen NiMH rechargeable battery 270 x 250 x 180 mm / 4.3 kg IEC 61010 1000 V CAT III - 600 V CAT IV IEC 61557 ADDITIONAL INFO · Test by voltage steps (CA 6549) · Compatible with the DataView® software ACCESSORIES / REPLACEMENT PARTS CA 1246 thermo-hygrometer CA 1821 thermometer See all the accessories on page 81 P01654246 P01654821 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 353 ELECTRICAL SAFETY > ON-SITE INSULATION TESTERS > CA 6550 - CA 6555 CA 6550 - CA 6555 REF.: P01139715 REF.: P01139716 1000 V IP CAT IV 54 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Fixed and programmable test voltages from 40 V to 10 / 15 kV · Wide measurement range from 10 k to 30 T · 5 mA charging current · Digital graphical display and bargraph of the R(t) + U(t), i(t) and i(u) curves in real time · Ramp and voltage step tests SPECIFICATIONS Test voltages Insulation measurement Ranges CA 6550 10 kV CA 6555 15 kV 500 V: 10 k to 2 T 1,000 V: 10 k to 4 T 2,500 V: 10 k to 10 T 5,000 V: 10 k to 15 T 10,000 V: 10 k to 25 T 15,000 V: 10 k to 30 T Fixed test voltages Variable test voltages Adjustment increment for variable voltages Ramp mode 500 / 1,000 / 2,500 / 500 / 1,000 / 2,500 / 5,000 / 10,000 V 5,000 / 10,000 / 15,000 V 40 V 10,000 V 40 V 15,000 V 3 preconfigurable 3 preconfigurable voltage values voltage values Variable: 40-10 kV Variable: 40-15 kV Increment: 40 V - 1 kV: 10 V Increment: 40 V - 1 kV: 10 V 1 kV - 10 kV: 100 V 1 kV - 15 kV: 100 V 3 preconfigurable ramps: start voltage / end voltage / duration Ramp configuration range 40-1,100 V / 500-10,000 V 40-1,100 V / 500-15,000 V Step mode Voltage measurement before and after test Capacitance measurement (> 500 V) Leakage current measurement Discharge after test Up to 10 plateaux (values and duration configurable for each plateau) AC: 0 2,500 V DC: 0 4,000 V 0.001-9.999 F / 10.00-19.99 F 0 - 8 mA Yes / automatic Additional test stop modes I-limite Early-break Timer Debug mode Burn-in Calculation of ratios Calculation of R at ref. temp. Measurement display filter Graphics on display Data storage Communication PC software Power supply Electrical safety Dimensions / weight Programmable 0.2 - 5 mA di / dt Up to 99:59 minutes Permanent test PI, DAR, DD, SV, DR (ppm / V) Yes 3 filters with variable time constant R(t)+u(t) ; i(t) ; i(u) 256 recordings, 80,000 cts R, U, I and date-stamp Optically-isolated port for USB and RS232 connection DataView® NiMH rechargeable batteries, 8 x 1.2 V / 4,000 mAh Charging by 90-260 V 50/60 Hz external voltage 1000 V CAT IV - IEC 61010-1 and IEC 61557 406 x 330 x 174 mm, 6 kg approx. CONTENTS CA 6550 and CA 6555 delivered with a shoulder bag containing: · 2 safety leads 3 m long equipped with an HV plug at each end (red / blue) · 1 guarded safety lead 3 m long equipped with an HV plug at one end and an HV plug with rear connection at the other end (black) · 3 crocodile clips (red, blue, black) · 2 x CAT IV 1000 V test probes (red / black) for voltage measurement · 1 blue lead 0.5 m long with rear connection · 1 mains power cable 2 m long · DataView® software · 1 optical / USB communication cable · 1 CD-Rom containing the user's manual ADDITIONAL INFO · Resistance calculation at a reference temperature · memory capacity: 80.000 measurements · Optically-isolated USB communication · 2 levels of diagnostics available : - Go / No go - Qualitative measurement for preventive maintenance ACCESSORIES / REPLACEMENT PARTS Set of 3 red, blue and black simplified HV safety leads with rear connection 3 red / blue / black crocodile clips See all the accessories on page 81 P01295465 P01103062 542 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > LEAKAGE CURRENT CLAMP > F65 F65 REF.: P01120761 10 µA 10,000 counts TRMS Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Quick leakage-current testing · Troubleshooting of insulation faults on live installations · 50 / 60 Hz filter CONTENTS F65 delivered with 1 shoulder bag · 1 set of straight banana / elbowed banana leads · 1 set of safety test probes · 2 x 1.5 V LR03 batteries ACCESSORIES / REPLACEMENT PARTS Red + black crocodile clips in blister pack (set of 2) Elbowed test-probe leads, 1.5 m (1 red / 1 black) See all the accessories on page 81 P01295457Z P01295456Z SPECIFICATIONS Display Acquisition Function Unit Current mAa c Aa c Va c Voltage Vd c Resistance Audible continuity A Frequency V Max. value Backlighting Deactivatable automatic power-off Clamping diameter Dimensions / weight Standards Installation category Enclosure protection rating Calibre Resolution 60 mA 600 mA 10 A 80 A 100 A 600 V 600 V 1 k Buzzer < 35 100 Hz 1 kHz 100 Hz 1 kHz 10 A 100 A 1 mA 10 mA 0.1 V 0.1 V 0.1 0.1 Hz 1 Hz 0.1 Hz 1 Hz F65 10,000 counts - 2 measurements / s TRMS Accuracy with 50-60 Hz filter 1.2 % ± 5 cts 2.5 % ± 5 cts (60-500 Hz) 3.5 % ± 10 cts (500-3 kHz) 1.2 % ± 5 cts 2.5 % ± 5 cts (60-500 Hz) 3.5 % ± 10 cts (500-3 kHz) 5 % ± 5 cts 5 % ± 5 cts (50-60 Hz) 1.0 % ± 5 cts (50-60 Hz) 1.2 % ± 5 cts (60-500 Hz) 2.5 % ± 5 cts (500-3 kHz) 1 % ± 2 cts 1 % + 3 cts (Vte st 3.3 Vdc) 0.5 % ± 2 cts (I > 10 mA) 0.5 % ± 2 cts (V > 5 Vac) 100 ms Yes Yes 28 mm 218 x 64 x 30 mm / 280 g (with batteries) IEC 61010-1 / IEC 61010-2-032 / IEC 61010-2-033 300 V CAT III IP 30 as per EN 60529 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 355 ELECTRICAL SAFETY > EARTH TESTER > SELECTION GUIDE CHOOSE YOUR EARTH TESTER CA 6422 page 57 CA 6424 page 57 CA 6460 page 58 CA 6462 CA 6470N CA 6471 page 58 TERCA 3 page 59 page 59 CA 6472 page 60 CA 6416 page 62 CA 6417 page 62 CA 6418 page 62 Type Earth 3P method 4P method Automatic coupling Selective earth Earth clamp 4P method + clamp 2-clamp method Pylon earth measurement* Resistivity Manual Automatic Contact voltage measurement Potential measurement Continuity Earth potential Measurement frequency Single frequency: 128 Hz Single frequency: 2,083 Hz 41 to 512 Hz 41 to 5,078 Hz Measurement of Rs, Rh Measurement of Ustray Display Analogue LCD LCD, 3 displays OLED Data storage / Communication Data storage Communication Optical USB interface Bluetooth® Power supply Batteries Rechargeable batteries PC / Tablet software GTT / DataView® GTC Tablet application * Associated with CA 6474 Earth testers ( 52% / 62% / 72% ) Earth and resistivity testers Earth testers 562 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > EARTH TESTERS > CA 6422 - CA 6424 CA 6422 - CA 6424 REF.: P01127012 REF.: P01127014 65 600 V IP CEI CAT IV 61557 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · 2P resistance / 3P earth resistance measurement up to 50 k for highly resistive terrain · Automatic stabilization of the measurement · Calculation of 52% / 62% / 72% average and % deviation · Leakage current measurement from 0.5 mA · Power supply by batteries rechargeable via the mains, USB socket or vehicle cigarette lighter CONTENTS · CA 6422 delivered with 6 x LR6 type AAA batteries, 1 quick start guide, 1 safety datasheet, 1 test report with measurement results, WEB link / QR Code for downloading the manuals · CA 6424 delivered with 1 carrying bag, 6 NiMH batteries, 1 USB 2 A power supply, 1 USB micro-razor power cable, 1 multilingual quick start guide, 1 safety datasheet, 1 battery datasheet, 1 test report with measurement results, WEB link / QR Code for downloading the manuals ACCESSORIES / REPLACEMENT PARTS Carrying bag G72 current clamp 4-point hands-free strap 15 m earth kit 50 m expert earth kit See all the accessories on page 81 P01298006 P01120872 HX0302 P01102017 P01102021 SPECIFICATIONS CA 6422 CA 6424 Voltage (UHE) Range - 0.1-600 V Resolution - 0.1 V Accuracy - ± (1 %R + 1 ct) 2P resistance Range 0.05-99.99 / 80.0-999.9 / 0.800-9.999 k / 8.00-50.00 k Resolution 0.01 / 1 / 10 / 100 Accuracy ± (2 %R + 10 cts) / ± (2 %R + 2 cts) / ±(2 %R + 1 ct) / ± (2 %R + 1 ct) Cable compensation - up to 5 3P earth resistance Range 0.5 - 2.000 k 0.5 - 50.00 k Resolution 0.01 / 0.1 / 1 0.01 / 0.1 / 1 / 10 Accuracy ±(1 %R + 10 cts) / ±(1 %R +2 cts) / ±(1 %R + 1 ct) Measurement frequency 128 Hz or 256 Hz No-load voltage ±10 V peak Measurement mode One-shot or permanent Data storage Registers: RE @ 62%; RE @ 52%; RE @ 72% Calculation of average - Calculation of the average and the % deviation in relation to the average RH stake resistance measurement Range - 0.05-9.999 k / 8 - 49.99 k Resolution - 1 / 10 Accuracy - ±(10 %R + 1 ct) USE voltage measurement Range - 0.10 - 99.99 Vac / 80.0 - 600 Vac Resolution - 0.01 V / 0.1 V Accuracy - ±(2 %R + 2 cts) Current measurement (via optional G72 clamp) Range 0.5 - 999.9 mA / 0.800-9.999 A / 8.00-60.00 A Resolution 0.1 / 1 / 10 mA Accuracy ±(1 %R + 4 cts) / ±(1 %R + 2 cts) Display Backlit custom 206-segment LCD Measurement mode R 2P (), R 3P () V, I, R 2P (), R 3P () Power supply 6 x LR 6 or AA batteries 6 x NiMH rechargeable batteries, charging time approx.. 6 hrs Charger - Internal via mains / USB adapter supplied Automatic power-off - Deactivatable Battery life > 2,000 x 3P earth measurements at 100 >1,500 x 3P earth measurements at 100 Dimensions / weight 223 x 126 x 70 mm / 1 kg Environment Operation: -10 to +50°C / Storage: -40 to +70°C (without batteries / accumulators) Protection Up to 600 V on any of the input terminals IP / IK index IP 65 as per IEC 60529 / IK 04 as per IEC 50102 Drop test 1 metre as per IEC 61010-1 Standards / electrical safety EMC: IEC 61326-1; IEC 61010-2-030 / 600 V CAT IV Compliance with IEC 61557 IEC 61557-1 and IEC 61557-5 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 357 ELECTRICAL SAFETY > EARTH TESTERS > CA 6460 - CA 6462 CA 6460 - CA 6462 REF.: P01126501 REF.: P01126502 IP 53 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology EARTH / RESISTIVITY / COUPLING TESTERS STRENGTHS · 3-in-1 testers: resistivity, earth and coupling · Validation of the measurement by self-diagnosis: 3 LEDs indicating the presence of faults liable to make the measurement result invalid · Highly-resistant site-proof casing with lid for use in harsh field conditions · Large LCD display with backlighting CONTENTS C A 6460 delivered with 8 x 1.5 V LR06 batteries CA 6462 delivered with 1 mains lead for recharging ACCESSORIES / REPLACEMENT PARTS European 2P mains lead HRC fuse 0.1 A - 250 V (x 10) See all the accessories on page 81 P01295174 P01297012 SPECIFICATIONS Measurement Type Measurement range Resolution Accuracy No-load voltage Frequency Alarms Power supply Display Electrical safety Dimensions Weight CA 6460 CA 6462 Earth / resistivity / coupling 3P & 4P 0.01 to 2,000 (in 3 automatic calibres) 10 m / 100 m / 1 (depending on calibre) ± (2 % + 1 ct) 42 V peak 128 Hz 3 fault presence LEDs 8 x 1.5 V LR06 batteries NiMH rechargeable battery 2,000-count digital LCD IEC 61010 & IEC 61557 273 x 247 x 127 mm (handle folded away) 2.8 kg 3.3 kg 582 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > EARTH TESTERS > CA 6470N TERCA 3 - CA 6471 CA 6470N TERCA 3 - CA 6471 REF.: P01126506 REF.: P01126505 IP 50 V 53 CAT IV Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology CA 6470N TERCA 3 EARTH / RESISTIVITY / COUPLING / CONTINUITY TESTER CA 6471 EARTH / SELECTIVE EARTH / RESISTIVITY / COUPLING / CONTINUITY TESTER STRENGTHS CA 6470N TERCA 3: · 4-in-1 tester: Earth / Resistivity / Coupling / Continuity CA 6471 · 5-in-1 tester, Earth / Selective Earth / Resistivity / Coupling / Continuity · Suitable for industry, housing and electricity companies CONTENTS C A 6470N delivered with : · 1 mains adapter · 1 x 2-pole mains power cable for battery recharging on the mains · Data export software · 1 optical / USB communication cable · 1 CD-Rom containing the user manual · 5 specifications labels CONTENTS CA 6471 delivered with: · 1 mains adapter · 1 x 2-pole main power cable for battery recharging on the mains · Data export software · 1 optical / USB communication cable · 2 x C182 clamps with 2 safety leads · 1 carrying bag · 1 CD-Rom containing the user manual · 5 specifications labels SPECIFICATIONS CA 6470N CA 6471 3P method Range (automatic selection) 0.01 to 99.9 k Resolution 0.01 to 100 Test voltage 16 V or 32 V, selectable Measurement frequency 41 to 513 Hz, automatic or manual Test current Up to 250 mA Accuracy ± 2 % of value ± 1 ct 4P method Range 0.001 to 99.99 k Resolution 0.001 to 10 Test voltage 16 V or 32 V Measurement frequency 41 to 513 Hz, automatic or manual Test current Up to 250 mA Measurement accuracy ± 2 % of value ± 1 ct 4P method + 1 clamp Same as 4P method Soil resistivity measurement Measurement method Wenner or Schlumberger method with automatic calculation of the results and display in -metre Range (automatic selection) 0.01 to 99.99 k (max. r. 999 km) Resolution 0.01 to 100 Test voltage 16 or 32 V, selectable Measurement frequency 41 to 128 Hz, selectable Measurements with 2 clamps Range 0.1 to 500 Resolution 0.01 to 1 Measurement frequency Auto: 1611 Hz Manual: 128 Hz 1.367 Hz 1,611 Hz 1,758 Hz External voltage measurement Range (automatic selection) 0.1 to 65.0 Vac / dc DC and 15-440 Hz Accuracy ± 2 % of value ± 1 ct Resistance / Continuity - (earth bond test) Type of measurement 2P or 4P method, selectable Range (automatic selection) 2P: 0.01 to 99.9 k 4P: 0.001 to 99.99 k Accuracy ± 2 % of value ± 2 cts Test voltage 16 Vdc (polarity +. - or auto) Test current > 200 mA for R < 20 Data storage Storage capacity 512 test results Communication Optically-isolated USB Power supply Rechargeable battery Charger power supply External power supply with 18 Vdc / 1.5 A output or 12 Vdc vehicle power supply Dimensions / weight 272 x 250 x 128 mm / 3.2 kg Electrical safety 50 V CAT IV ACCESSORIES / REPLACEMENT PARTS DataView® report generation software Adapter for battery charging on vehicle cigarette lighter See all the accessories on page 81 P01102095 P01102036B TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 359 ELECTRICAL SAFETY > EARTH TESTER > CA 6472 CA 6472 REF.: P01126504 IP 50 V 53 CAT IV Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology EARTH / SELECTIVE EARTH / RESISTIVITY / COUPLING / CONTINUITY / PYLON EARTH TESTER STRENGTHS · All types of earth resistance measurement & pylon earth measurement (with the CA 6474) · Resistivity (Wenner + Schlumberger methods) · Earth coupling · Soil potential measurement · Continuity / resistance CONTENTS C A 6472 delivered with: · 1 mains adapter · 1 x 2-pole mains power cable for battery recharging on the mains · Data export software · 1 optical / USB communication cable · 2 x C182 clamps with 2 safety leads · 1 carrying bag · 1 CD-Rom containing the user manual · 5 specifications labels SPECIFICATIONS CA 6472 3P measurements Range (automatic selection) 0.01 to 99.9 k Resolution 0.01 to 100 Test voltage 10 V, 16 V, 32 Vrms or 60 V, selectable Measurement frequency 41 to 5,078 Hz, automatic or manual Test current Up to 250 mA Accuracy ± 2 %R +1 ct to 128 Hz Measurements with 2 clamps Range 0.01 to 500 Resolution 0.01 to 1 Measurement frequency Auto: 1,611 Hz - Manual: 128 Hz 1,367 Hz 1,611 Hz 1,758 Hz 4P method / 4P+clamp Range 0.001 to 99.99 k Resolution 0.001 to 10 Test voltage 10 V. 16 V. 32 V or 60 V, selectable Measurement frequency 41 to 5078 Hz, automatic or manual Test current Up to 250 mA Measurement accuracy ± 2 % of value ± 1 ct Soil resistivity measurement - 4P method Measurement method Wenner or Schlumberger method with automatic calculation of the results and display Range (automatic selection) 0.01 to 99.99 k ; r max. 999 km Resolution 0.01 to 100 Test voltage 10 V. 16 V. 32 V or 60 V, selectable Measurement frequency 41 to 512 Hz, selectable Earth potential measurement Measurement range 0.00 to 65.00 V Resolution 0.01 mV to 10 mV Measurement frequency 41 to 5,078 Hz Accuracy ± 5% ± 1 ct to 128 Hz External voltage measurement Range (automatic selection) 0.1 to 65.0 Vac / dc - DC and 15-450 Hz Accuracy ± 2 % of value ± 1 ct Resistance / Continuity measurement Type of measurement 2P or 4P method. selectable Range (automatic selection) 2P : 0.01 to 99.9 k 4P : 0.001 to 99.99 k Accuracy ± 2 % of value ± 2 cts Test voltage 16 Vdc (polarity +. - or auto) Test current > 200 mA for R < 20 Data storage Storage capacity 512 test results Communication Optically-isolated USB Power supply Rechargeable battery Charger power supply External power supply with 18 Vdc / 1.9 A output or 12 Vdc vehicle power supply Dimensions / weight 272 x 250 x 128 mm / 3.2 kg Electrical safety 50 V CAT IV ACCESSORIES / REPLACEMENT PARTS DataView® report generation software Adapter for battery charging on vehicle cigarette lighter See all the accessories on page 81 P01102095 P01102036B 602 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > EARTH TESTER > CA 6474 CA 6474 REF.: P01126510 IP 53 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology SPECIALLY FOR MEASUREMENTS ON PYLONS STRENGTHS · Used with the CA 6472 for measurements on pylons · Pylon earth resistance · Resistance of each pylon footing · Quality of overhead earth wire connection CONTENTS C A 6474 delivered with an accessories bag containing: · 1 connection cable · 4 BNC / BNC cables 15 m long · 4 AmpFlex® flexible current sensors 5 m long · 1 set of 12 identification rings for AmpFlex® with 15 m BNC cable · 2 cables (5 m green, 5 m black) with safety plugs on winder · 5 spade lug / Ø 4 mm banana plug adapters · 3 adjustable clamps · 1 calibration loop · 5 specifications labels Also available with 8 m AmpFlex® sensor: order reference P01126511 SPECIFICATIONS Measurements Type of measurement Range Accuracy Frequency Frequency sweep Dimensions Weight Power supply / Data storage / Display CA 6474 / PYLON BOX Overall pylon earth resistance Earth resistance of each pylon footing Overall line impedance Quality of overhead earth wire connection. Active measurement (injection by the CA 6472) Passive measurement (use of eddy currents) 0.067 to 99.99 k ± (5 % + 1 ct) 41 to 5,078 Hz Yes 272 x 250 x 128 mm 2.3 kg Provided by the CA 6472 ADDITIONAL INFO Possibility of connecting several AmpFlex® sensors in series for a length > 8 metres The complete Pylon Earth Kit is available to order with the code P01299930. It comprises: · CA 6472 · CA 6474 · AmpFlex® 5 m · 100 m earth kit For the 8 m AmpFlex® version of the complete pylon earth kit, please order: · CA 6472 reference P01126504 · CA 6474 reference P01126511 · 100 m earth kit reference P01102024 ACCESSORIES / REPLACEMENT PARTS Connection cable between the CA 6472 and CA 6474 15 m BNC / BNC cable See all the accessories on page 81 P01295271 P01295272 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 361 ELECTRICAL SAFETY > EARTH TESTERS > CA 6416 - CA 6417 - CA 6418 CA 6416 - CA 6417 40 REF.: P01122015 REF.: P01122016 600 V IP CAT IV CA 6418 REF.: P01122018 150 V IP CAT III 40 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Quick earth-loop testing · OLED screen and force compensation system · Loop resistance measurement from 0.01 to 1,500 (1,200 on CA 6418) · Current measurement from 0.5 mA to 20 A · Alarms available on and A, and on voltage with CA 6416 / CA 6417 · Storage of 300 time / date-stamped measurements; 2,000 on CA 6417 · Automatic display hold when the clamp is opened ADDITIONAL INFO · Automatic calibration of jaw gap at power-up · Oblong head for clamping all types of earth busbars (CA 6418) · Android application downloadable from Google Play (CA 6417) CONTENTS · 1 clamp delivered in a carrying case · 4 x 1.5 V LR06 batteries · 1 verification certificate · 1 CD-ROM containing the user's manual The CA 6417 is delivered with the simplified GTC driver as well. SPECIFICATIONS CA 6416 CA 6417 CA 6418 Measurement ranges () / Resolution () / Accuracy 0.010 to 0.099 / 0.001 / ±1.5 % ±0.01 0.010 to 0.099 / 0.001 / ±1.5 %R ±0.01 Loop ohmmeter 1,500-count display on CA 6416 / CA 6417 1,200-count display on CA 6418 0.10 to 0.99 / 0.01 / ±1.5 % ±2 r 1.0 to 49.9 / 0.1 / ±1.5 % ±r 50.0 to 99.5 / 0.5 / ±2 % ±r 100 to 199 / 1 / ±3 % ±r 200 to 395 / 5 / ±5 % ±r 400 to 590 / 10 / ±10 % ±r 0.10 to 0.99 / 0.01 / ±1.5 %R ±2 r 1.0 to 49.9 / 0.1 / ±1.5 %R ±2r 50.0 to 149 / 1 / ±2.5 %R ±2r 150 to 245 / 5 / ±5 %R ±2r 250 to 440 / 10 / ±10 %R ±2r 450 to 640 / 10 / ±15 %R ±2r 600 to 1,150 / 50 / Approx. 20 % 650 to 1200 / 50 / ±20 %R ±2r 1,200 to 1,500 / 50 / Approx. 25 % Frequencies Measurement frequency 2083 Hz Measurement frequency Transposition frequency 50, 60, 128 or 2,083 Hz 4.5 mV at 2,083 Hz Loop inductance measurement Measurement ranges (H) / Resolution (H) / Accuracy 10 to 100 / 1 / ±5 %±r 100 to 500 / 1 / ±3 %±r Measurement ranges (V) / Resolution (V) / Accuracy Contact voltage (calculated) 0.1 to 4.9 / 0.1 / ±5 %+r 5.0 to 49.5 / 0.5 / ±5 %+r 50.0 to 75.0 / 1 / ±10 %+r Ammeter 4,000-count display Setup Measurement ranges (A) / Resolution (A) / Accuracy 0.200 to 0.999 mA / 1 A / ±2 % ±50 A 0.5 to 9.995 mA / 50 A / ±2 %R ±200 A 1,000 to 2,990 mA - 3.00 to 9.99 mA / 10 A / ±2 % ±50 A 10.00 to 99.90 mA / 100 A / ±2 %R ±r 10.00 to 29.90 mA - 30.0 to 99.9 mA / 100 A / ±2 %±r 100.00 to 299.0 mA / 1 mA / ±2 %R ±r 100.0 to 299.0 mA - 0.300 to 0.990 A / 1 mA / ±2 %±r 0.300 to 2,990 A / 10 mA / ±2 %R ±r 1,000 to 2,990 A - 3.00 to 39.99 A / 10 mA / ±2 %±r 3.00 to 20.00 A / 100 mA / ±2 %±r Modes Standard or advanced Standard Alarms Configurable on Z, V and A Configurable on Z, I Buzzer Active / Inactive Active HOLD Manual or automatic PRE-HOLD Automatic power- off Active / Inactive General specifications Display 152-segment OLED. Active area 48 x 39 mm Max. clamping diam. Data storage Ø 35 mm 300 time-date-stamped 2,000 time-datemeasurements stamped measurements Ø 32 mm - L x H : 30 x 40 mm / 20 x 55 mm 300 time-date-stamped measurements Communication Bluetooth Class 2 Power supply 4 x 1.5 V LR06 batteries or 4 x NiMH batteries Battery life 1,440 measurements of 30 seconds each 2,440 measurements of 30 seconds each Calibration Automatic at startup Electrical safety IEC 61010 600 V CAT IV IEC 61010 100 V CAT IV, 150 V CAT III Ingress protection IP40 Dimensions / weight 55 x 95 x 262 mm / Approx. 935 g with batteries 56 x 106 x 300 mm / Approx. 1.2 kg with batteries ACCESSORIES / REPLACEMENT PARTS Bluetooth USB modem CL1 calibration loop See all the accessories on page 81 P01102112 P01122301 622 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > ELECTRICAL EQUIPMENT TESTERS > SELECTION GUIDE CHOOSE YOUR ELECTRICAL EQUIPMENT TESTER Insulation 50 Vd c 100 Vd c / 250 Vd c / 500 Vd c / 1,000 Vd c Dielectric tests 40 to 3,000 Va c 40 to 5,350 Va c 100 to 5,000 Va c Continuity I test 0.1 A I test 0.2 A; 10 A I test 25 A I test 4 A Voltage drop I test 10 A Discharge time at 34 V / 60 V / 120 V Discharge time Leakage current PE direct leakage method Differential leakage method Direct & differential method via clamp Substitution method Contact leakage method Functional test Active, reactive & apparent power values, voltage, current THD U, THD I Loop impedance and resistance Zs-loop (L-PE) (Trip), Calculation of Ik (PFC) Zs-loop (L-PE) (No Trip), Calculation of Ik (PFC) Zi-loop (L-N or L-L), Calculation of Idc (PSCC) RCD TEST PRCD x 0.5 / x1 / x5 x In RCD x 0.5 / x1 / x2 / x4 / x5 / x10 x In (AC, A, F, B, B+) Other functions Alarms Phase sequence Data storage / Communication Data storage Communication Result sent to printer Interfaces for START / STOP pedal and lamps Interface for barcode DOOR OPEN interface PC software Automatic test sequences CA 6161 page 64 (1 G) (except reactive) 50,000 tests USB USB MTT CA 6163 page 64 (50 G) (except reactive) 100,000 tests USB USB MTT CA 6165 page 65 (200 M) AC / DC SD RS232 / USB RS232 / USB MTLink TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 363 ELECTRICAL SAFETY > ELECTRICAL EQUIPMENT TESTERS > CA 6161 - CA 6163 CA 6161 - CA 6163 REF.: P01145811 REF.: P01145831 300 V IP CAT II 64 Auto Script Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Colour touch screen usable with insulating gloves · Automatic test scripts · Storage of up to 100,000 test · Multilingual interface · Dielectric test up to 3 kV / 5 kV, 25 A continuity, 1kV insulation · Direct, differential, substitution and contact leakage current ADDITIONAL INFO · Functional tests · Customizable visual inspections · Direct connection for pedals, indicator lamps and barcode / RFID readers · Direct automatic printing of Pass / Fail sticker CONTENTS CA 6161 delivered with: · 1 accessories bag containing: · 2 High-Voltage test guns with cables (3 m) · 2 cables with silicone insulation: 1 red, 1 black (3 m) · 1 black test probe · 1 three-point lead with separated wires (2.5 m) · 1 three-point lead with Euro socket (2.5 m) · 3 crocodile clips: blue, red and green · 3 crocodile test probes: blue, red and green · 1 bag containing 3 extension connectors · 1 USB-A-USB-B cable · 1 x C19 Euro mains power cable (2.5 m) · 1 Quick Start Guide · 1 product safety datasheet · 1 test report with measurement list CA 6161 with continuity accessories included: · 2 x 10 A double continuity cables (2.5 m) · 3 crocodile clips, 1 red, 2 black CA 6163 with continuity accessories included: · 1 x 25 A Kelvin gun (3 m) · 1 x 25 A Kelvin crocodile clip (2.5 m) SPECIFICATIONS CA 6161 CA 6163 Socket test High voltage AC / AC Ramp Resolution / accuracy Max. current I Measurement Range / accuracy 40 3,000 V 40 5,350 V 10 V / ±1 % R 200 mA 100 mA / 200 mA ±2 % R Insulation Test voltage Maximum measurement / accuracy Continuity Measurement current 100 V / 250 V / 500 V / 1,000 V 1,000 M / ±10 % R 50 G / ±10 % R 0.1 A; 0.2 A; 10 A (voltage drop) - 25 A Measurement range 20 / 120 ; 2 / 20 / 60 ; 0.5 20 / 120 ; 2 / 20 / 60 ; 0.5 ; 0.4 Accuracy ±2 % R ±2 % R Leakage current Direct I-PE- & I-differential Range / accuracy Socket : 30 mA / ±2 % R Clamp: 40 A / ±2 % R I-substitution - Socket: 50 mA ±2 % R Contact leakage - Socket and three-point: 30 mA / ±(2 %R + 2 cts) measurement network: unweighted, weighted Loop / fuse table Zs No Trip (Zs & Rs) Range / Accuracy 2,000 / ±5 % R / Ik (display range) 20 kA ZS high current and Zi Range / Accuracy 400 / ±5 % R / Ik (display range) 20 kA Inductance Range / resolution / accuracy 15 mH / ±10 % R UF measurement 25.0 V / ±(15 %R + 3 cts); 70.0 V / ±(5 %R + 2 cts) RCD & PRCD Types AC, A, F, B; G, S Mains voltage & calibres 440 Vac max ; 10 / 30 / 100 / 300 / 500 / 1,000 mA / Var (6 1,000 mA) Pulse test x 0.5; x 1; x 2, x 4; x 5; x 10 IDn Trip time Range / accuracy 300 ms / ±(0 %R + 20 ct) Ramp test 10 / 30 / 100 / 300 / 500 / 1,000 mA ; 0.3 x IDn to 1,06 x IDn in 22 steps Trip current Resolution / accuracy 0.1 mA; -0% +(7 %R + 2 mA) UF measurement 25.0 V / ±15 % R; 70.0 V / ±5 % R Discharge time at 34 V, 60 V, 120 V Time / Up voltage 0.1 s 9.9 s / 0.1 s / ±(1 %R + 1 ct); Socket & threepoint: 34 V ; 60 V; 120 V; Power values Quantities Socket: U, I, P, S , F, Pf, THD U, THD I Measurement range 265 Vac; 16 A; 4 kW; 7 kVA; 45-55 Hz; (-1,+1); 8.0 %; 100 % Quantities Three-point + clamp: U, I, P, S , F, cos , Pf, THD U, THD I Measurement range 440 Vac; 16 A; 10.12 (1) / 30.36 (3 ) kW ; 10.12 (1) / 30.36 (3 ) kVA; 45-55 Hz; (-1,+1); 100 %; 100 % / PF (-1,+1) Phase rotation Installation voltage and frequency 190 - 440 V ; 45-55 Hz G72* current clamp Measurement range / accuracy 40 A / ±1 % R General specifications Display Colour touch screen; TN 800 x 480, 5" Data storage 50.000 tests 100.000 tests Timer max. 40 min (depends on type of test) Communication 1 x USB-B ; 2 x USB-A ; Wifi Interfaces START / STOP pedals, DOOR Open, HV gun trigger, 4 lamps, barcode reader, RFID reader, sticker printer Power supply 230 Vac; -15% + 10 %. Dimensions / weight 340 x 405 x 194 mm; 9kg (CA6161) / 15kg (CA6163) Temperature Operation: 0; + 45 °C; Storage: - 40; + 60 °C Protection IP 40 open / IP 64 closed Electrical safety IEC 61010-1; IEC 61010-2-030; IEC 61010-2-034; 300 V CAT II; 300 V CAT III; 600 V CAT III; IEC 61010-2-032 Standards IEC 61557-1; -2; -3; -4; -6; -7; -10; -13;-14; -16 (part l) * optional 642 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > ELECTRICAL EQUIPMENT TESTER > CA 6165 CA 6165 REF.: P01145851 300 V IP CAT II 50 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Capacitive colour touch screen · Manual or automatic test sequences · Storage of the tests on memory card up to 32 GB · 5 kVac / 6 kVdc HV dielectric, 25 A continuity, insulation at 1,000 V · Substitute direct leakage current, PE, differential leakage current and touch leakage current ADDITIONAL INFO · External and internal discharge time up to 10 s / 550 V peak · Functional test: P, Q, S, PF, Cos , THDU, THDI, U and I · Inputs-outputs transmitted to pedal, indicator lamps, PC · Compatible with 230 V / 115 V TT, TN or IT networks CONTENTS CA 6165 delivered with: · 1 accessories bag containing · 2 high-voltage guns with cables (2 m) · 2 test probes (red / black) · 3 red crocodile clips, 2 black crocodile clips · 1 RS232 cable · 1 USB cable · 1 EURO mains power cable · 2 double continuity cables 2.5 m long · 1 set of insulation cables 2.5 m long (red / black) · 1 single continuity cable 1.5 m long (red) · MTLink PC software on CD-ROM · 1 EURO discharge cable · 1 multilingual safety datasheet · 1 measurement report SPECIFICATIONS CA 6165 High voltage AC / AC Programmable Range 0 V to 1,999 V 2 kV to 5 kV Resolution / Accuracy 1 V / ± 3 %R 10 V / ± 3 %R DC / DC Programmable Range 0 V to 1,999 V 2 kV to 6 kV Resolution / Accuracy 1 V / ± 3 %R 10 V / ± 3 %R Current Range AC: I apparent & resistive 0 mA to 99.9 mA I capacitive: -99.9 mA to + 99.9 mA DC: 0.01 mA to 9.99 mA Resolution / Accuracy AC: I apparent: 0.1 mA / ±3 %R ± 3 cts, indicative for I capacitive and I resistive DC : 0.01 mA / ± (5 %R + 3 cts) Continuity 0.2 A; 4 A; 10 A; 25 A, Voltage drop (10 A) Range 0 to 19.99 20 to 99.9 100 to 199.9 200 to 999 Resolution 0.01 0.1 0.1 1 Accuracy ± (2 %R + 2 cts) ± 3 %R ± 5 %R - Voltage drop (10 A) 0.00 V to 99.9 V Insulation Voltage 50 V / 100 V 250 V / 500 V / 1,000 V Range 0 to 19.99 M 20 M to 99.9 M 0 to 19.99 M 20 M to 199.9 M Resolution 0.01 M 0.1 M 0.01 M 0.1 M Accuracy ± (5 %R + 2 cts) ± 20 %R ± (3 %R + 2 cts) ± 10 %R Leakage current Method Subs. I PE Diff. Contact Range 0.00 to 19.99 mA 0.00 to 19.99 mA 0.00 to 19.99 mA 0.00 to 19.99 mA Resolution 10 A 0.01 mA 0.01 mA 0.01 mA Accuracy ± (5 %R + 3 cts) ± (3 %R + 3 cts) ± (3 %R + ± ( 3 %R + 5 cts) 3 cts) Discharge time at 34 V, 60 V, 120 V Time Range: 0 to 9.9 s Res. : 0.1 s Accuracy : ± (5 %R + 2 cts) Up voltage Range: 0 to 550 V Res. : 1 V Accuracy : ± (5 %R + 3 cts) Power values Active (P) App. (S) Reactive (Q) Range / resolution 0 to 3.70 kW / 0.01 W to 10 W 0 to 3.70 kVA / 0.01 VA to 10 VA 0 to 3.70 kVAr / 0.01 VAr to 10 VAr Accuracy ± (5 %R + 5 cts) ± (5 %R + 10 cts) ± (5 %R + 10 cts) Others PF, Cos , THDi , THDu ; (5 %R + 5 D) Voltage 0.0 V to 199 V / 0.1 V / ± (3 %R + 10 ct) 200 to 264 V / 1 V / ± 3 %R Current 0 to 999 mA / 1 mA / ± (3 %R + 5 ct) 1.00 to 16.00 A / 10 mA / ± 3 %R General specifications Display TFT colour screen, 480 x 272 pixels Data storage On microSD card Communication interfaces RS232, USB, Bluetooth, Input / Outputs (2 x DB9) Power supply 110 V / 230 V - 50 Hz / 60 Hz; Max. consumption: 600W / 4.5 kW if charged on mains test socket Dimensions / weight 435 x 292 x 155 mm / 17 kg Temperature Operation: 0 °C to +40 °C; Storage: -10 °C to + 60 °C Protection IP40 open / IP50 closed Electrical safety 300 V CAT II / 600 V CAT II (DISCH1 / DISCH2) TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 365 ELECTRICAL SAFETY > NOTES NOTES 662 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > NOTES NOTES TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 367 ELECTRICAL SAFETY > TESTERS > SELECTION GUIDE CHOOSE YOUR TESTER MICROOHMMETERS PHASE ROTATION AND / OR MOTOR TESTERS 4-wire measurement method (Kelvin) Measurement range Resolution CA 6240 page 69 400 1 CA 6255 page 69 2,500 0.1 CA 6292 page 70 1 0.1 Measurement current 10 A / 1 A / 100 mA / 10 mA 10 A / 1 A / 100 mA / 10 mA / 1 mA Automatic 50 / 100 / 150 and 200 A Manual from 20 to 200 A Inductive mode Alarms Temperature compensation Communication USB / RS232 Normal Inductive, non-inductive, Normal / BSG = non-inductive auto Both Sides Grounded Data storage (measurements) 100 1500 8000 Automatic recording *BSG = 2 côtés à la terre Power supply NiMH NiMH rechargeable batteries rechargeable batteries Mains Operating mode Operating voltage with connection Operating voltage without connection Power supply CA 6608 page 72 With connection 40 to 850 Vac between phases By the measurement CA 6609 page 72 With and without connection 40 to 600 Vac between phases 120 to 400 Vac between phases 9 V battery CABLE AND METAL CONDUCTOR LOCATOR Operation with / without voltage Location of a short-circuit / circuit break Location of cables, conductors or metal pipes CA 6681 E / R page 73 RATIOMETERS BATTERY CAPACITY TESTERS Range of VT / PT ratios Range of CT ratios Battery life Data storage Communication DTR 8510 page 71 0.8000 to 8,000 / 1 0.8000 to 1,000 / 1 up to 10 hours 10,000 tests Optical USB Measurement range min / max Resolution min / max Measurement frequency Comparison function Manual data storage (no. of locations) Automatic data storage (no. of locations) CA 6630 page 72 40 m / 40 10 / 10 m 1 kHz 99 sets of settings 999 9,600 682 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > MICRO-OHMMETERS > CA 6240 | CA 6255 CA 6240 53 REF.: P01143200 50 V IP CAT III Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology CA 6255 REF.: P01143221 50 V IP CAT III 53 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · 4-wire measurement method · Automatic current reversal · Test current up to 10 A · 1 resolution · Automatic recording "on the fly" or manual recording SPECIFICATIONS Measurement method Range 4,000 Accuracy 0.25 % ±2 cts Resolution 1 Measurement current 10 A Data storage Communication output Power supply Dimensions / weight Electrical safety CA 6240 4-wire method 40 m 400 m 4,000 m 40 0.25 % 0.25 % 0.25 % 0.25 % ±2 cts ±2 cts ±2 cts ±2 cts 10 0.1 m 1 m 10 m 1 A 1 A 100 mA 10 mA 100 measurements Optical link / USB NiMH rechargeable battery 273 x 247 x 280 mm / 5 kg IEC 61010 - 50 V CAT III 400 0.25 % ±2 cts 100 m 10 mA ADDITIONAL INFO · The CA 6240 is compatible with the DataView® software STRENGTHS · Optimized measurement on inductive objects · 4-wire measurement method · Automatic compensation of stray currents · Test current of up to 10 A · Measurements up to 2,500 , resolution 0.1 · Integrated "temperature compensation" function SPECIFICATIONS CA 6255 Measurement method 4-wire method Range 5.0000 m 25.000 m 250.00 m 2500.0 m 25.000 250.00 2500.0 Accuracy 0.05 % +1 0.05 % 0.05 % 0.05 % 0.05 % 0.05 % 0.05 % +3 +30 +0.3 m +3 m +30 m +300 m Resolution 0.1 1 10 0.1 m 1 m 10 m 100 m Measurement current 10 A 10 A 10 A 1 A 100 mA 10 mA 1 mA Measurement mode Temperature compensation Data storage Inductive, non-inductive, non-inductive with automatic trigger By temperature sensor or manual 1,500 measurements Communication output RS232 link Power supply NiMH rechargeable battery Dimensions 270 x 250 x 180 mm / 4 kg Electrical safety IEC 61010 - CAT III 50 V ADDITIONAL INFO · The CA 6255 is compatible with the DataView® software · Possibility of connecting the Pt100 sensor (option) directly to the instrument CONTENTS CA 6240 delivered with: · 1 shoulder bag · 1 set of 2 x 10 A Kelvin clamps with 3 m cable · 1 European 2P mains power cable · Data export software · 1 optical / USB communication cable CONTENTS CA 6255 delivered with a bag containing: · 1 set of cables 3 m long terminated by Kelvin clamps · 1 Euro mains power cable 2 m long · 1 CD-ROM containing the MOT (Micro-Ohmmeter Transfer) software · 1 RS 232 communication cable · 1 CD-ROM containing the user's manual in 9 languages ACCESSORIES / REPLACEMENT PARTS Double 1 A test probes (x 2) Mini Kelvin clamp (set of 2) See all the accessories on page 82 P01102056 P01101783 ACCESSORIES / REPLACEMENT PARTS Doubles 1 A test probes (x 2) Mini Kelvin clamp (set of 2) See all the accessories on page 82 P01102056 P01101783 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 369 ELECTRICAL SAFETY > MICRO-OHMMETERS > CA 6292 CA 6292 REF.: P01143300 IP 54 BSG Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Permanent test at 100 A and for up to 120 s at 200 A · Test current up to 200 A · Resistance from 0.1 to 1 · Safe measurements: BSG method (Both Sides Grounded) · Storage of up to 8,000 measurement results ADDITIONAL INFO · The backlit LCD screen with its 4 lines of 20 characters is easy to read whatever the environment. CONTENTS CA 6292 delivered with a hard case containing: · 1 set of 2 Kelvin leads 6 m long (red / black) with adjustable-clamp connections · 1 green earth lead 3 m long with 1 crocodile clip · 1 USB cable 1.5 m long · 1 T1 5 A 250 V fuse mounted in the instrument · 1 European mains power lead · 1 CD-ROM containing the DataView® software · 1 CD-ROM containing the user manual in 5 languages SPECIFICATIONS CA 6292 Test current Programmable from 20 to 200 A Resistance 0.1 to 2 m 2 to 200 m 200 m to 1 Resolution 0.1 (200 A max) 10 1 m (25 A max at 200 m) ( 5 A max at 1 ) Accuracy ± 1% from 50 to 1 Output voltage 110 Vac: 4.2 V @ 200 A 220 Vac: 8.6 V @ 200 A Maximum load resistance 110 Vac: 20 m @ 200 A 220 Vac: 42 m @ 200 A Measurement method 4 Kelvin-type connection terminals Test mode Normal or Both Sides Grounded (BSG) Test duration Adjustable from 5 to 120s @ 200 A Unlimited below 100 A Data storage Up to 8,000 measurement results Interface USB 2.0 Software DataView® Power supply 100 to 240 Vac - 50 / 60 Hz Dimensions 502 x 394 x 190 mm Weight Approx. 13 kg Operating temperature 0 °C to +55 °C Storage temperature -10 °C to +70 °C Humidity 95% RH Protection Protected against voltage surges, short-circuits, overheating and overvoltage on the safety terminals Ingress protection IP54 Electrical safety IEC 61010-1 Consumption 1,500 VA max Current measurement with the MR6292 clamp available as an option Measurement range 1.0 50.0 Adc Resolution 0.1 mA Intrinsic uncertainty ± (1.5% + 2 cts) Output signal 10 mV / Adc Load impedance > 100 k / / 100 pF Influence of conductor position in jaws 0.50 % ACCESSORIES / REPLACEMENT PARTS 1 set of 2 Kelvin leads 6 m long (red / black) adjustable-clamp connections 1 green earth lead with crocodile clip See all the accessories on page 82 P01295486 P01295488 702 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > RATIOMETER > DTR 8510 DTR 8510 53 REF.: P01157702 50 V IP CAT IV Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Measurement of the transformation ratio of power, voltage and current transformers · Storage of up to 10,000 measurement results · Displays the transformation ratio, the excitation current, the winding polarity and the percentage deviation from the rated values · Direct reading of the transformation ratio from 0.8000:1 and up to 8000.0:1 · Tests performed by excitation of the primary with measurement on the secondary ADDITIONAL INFO · Up to 10 hours' continuous operation thanks to the rechargeable NiMH batteries CONTENTS DTR 8510 · 1 shoulder bag · 1 set of leads 4.6 m long with crocodile clips · 1 external battery charger with mains lead · 1 USB cable · 1 NiMH battery datasheet · DataView software on CD-Rom ACCESSORIES / REPLACEMENT PARTS Set of 2 cables 4.6 m long USB lead See all the accessories on page 82 P01295143A P01295293 SPECIFICATIONS Range of ratios (TT / TP) Accuracy (VT / PT) Range of ratios (CT) Accuracy (CT) Excitation signal Display of excitation current Excitation frequency Display Available languages Measurement method Power supply Battery life Battery charger Charging time Data storage Date / time Communication Software Dimensions / weight Connection Cables Casing Vibrations Shocks Falls Ingress protection Safety DTR 8510 Automatic: 0.8000 to 8,000:1 Range of ratios Accuracy (% of reading) 0.8000 to 9.9999 ± 0.2 % 10.000 to 999.99 ± 0.1 % 1,000.0 to 4,999.9 ± 0.2 % 5,000.0 to 8,000.0 ± 0.25 % Automatic range: 0.8000 to 1,000.0 ± 0.5 %R ± 0.5%L VT / PT mode: 32 Vrms max. CT mode: auto level 0 to 1 A, 0.1 to 4.5 Vrms Range: 0 to 1,000 mA; Accuracy: ± (2 %R + 2 mA) 70 Hz Alphanumeric LCD, 2 lines of 16 characters with adjustment of the contrast and backlighting. Easy to read in both day and night conditions French, English, Spanish, Italian, German, Portuguese As per the IEEE Std C57.12.90TM standard 2 x 12 V, NiMH rechargeable batteries, 1,650 mAH Up to 10 hours in continuous operation, low battery alert Universal input (90 to 264 Vrms ), smart charger < 4 hours for full charge 10.000 tests Power supply by dedicated battery, real-time clock USB 2.0, optical isolation, 115.2 kB Delivered with the DataView® analysis software 272 x 248 x 130 mm / 3.7 kg XLR connectors Screened H and X cables, length 4.6 m (15 ft), equipped with colour-coded crocodile clips Rugged polypropylene casing, UL 90 V0 IEC 68-2-6 (1.5 mm at 55 Hz) IEC 68-2-27 (30 G) IEC 68-2-32 (1 m) IP 40 with lid open as per EN 60529 IP 53 with lid closed as per EN 60529 EN 61010-1, 50 V CAT IV; pollution degree 2 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 371 ELECTRICAL SAFETY > TESTERS > CA 6608 - CA 6609 | CA 6630 CA 6608 - CA 6609 40 REF.: P01191304 REF.: P01191305 600 V IP CAT III Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology CA 6630 REF.: P01191303 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology PHASE ROTATION AND / OR MOTOR TESTERS BATTERY CAPACITY TESTERS STRENGTHS · Zero adjustment function for compensation of the voltage circuit displayed · 2-display LCD screen · 7-hour battery life in continuous operation with 6 x 1.5 V batteries (not supplied) · Capacity test from 35 Ah to 500 Ah · Nickel-Cadmium, Lithium-Ion, Nickel-Metal-Hybrid or Lead-Acid batteries STRENGTHS · Indication of phase presence or absence · Determination of a motor's rotation direction with or without contact (CA 6609 only) · Automatic tests as soon as the connections have been set up · Terminals and cables identified by colour coding to simplify connection SPECIFICATIONS Operating voltage according to phase rotation Frequency range Power supply Dimensions Weight Electrical safety CA 6608 CA 6609 40 to 850 Vac between phases With connections: 40 to 600 Vac between phases Without connection: 120 to 400 Vac between phases 15 to 400 Hz Self-powered via the measurement inputs 9 V battery 130 x 69 x 32 mm 130 g 170 g IEC 61010-1 600 V CAT III IEC 61557-7 CONTENTS CA 6608 phase rotation testers delivered in a shoulder bag with: · 3 test leads · 3 crocodile clips CA 6609 phase rotation and motor tester delivered in a shoulder bag with: · 3 test leads · 3 crocodile clips SPECIFICATIONS Resistance measurement Range Resolution Measurement current Accuracy Measurement Measurement frequency Voltage measurement Range Resolution Accuracy Max. consumed power Mechanical specifications Dimensions Weight CA 6630 40 m 400 m 4 40 10 100 1 m 10 m 37.5 mA 3.75 mA 375 A 37.5 A ± (1 %R + 8 digits) Temp. coeff.: ± ( 0.1 %R + 0.5 digit) / °C 1.5 mVac 1 kHz ± 10 % 4 V 40 V 1 mV 10 mV ± (0.1 %R + 6 digits) 1 VA 250 x 100 x 45 mm 500 g batteries included CONTENTS 1 hard case containing: · CA 6630 · 1 set of 2 measurement leads 1 m long terminated by retractable test probes · PC data transfer software to export and process the stored data · 1 CA 6630 / PC connection cable ACCESSORIES / REPLACEMENT PARTS Set of 2 leads with retractable test probes See all the accessories on page 82 P01102103 722 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > CABLE AND METAL CONDUCTOR LOCATOR > CA 6681 CA 6681 REF.: P01141626 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Can be used on live or non-current-carrying installations · Digital, visual and audible indication to track the conductor intuitively · Large LCD screen with indication of the transmission power, the digital identification code and the voltage present on the circuit tested. CONTENTS 1 hard case containing · 1 CA 6681E transmitter · 1 CA 6681R receiver · 1 set of 2 red / black leads, straight male isolated Ø 4 mm banana / elbowed male isolated Ø 4 mm banana, 1.5 m long · 1 set of 2 red / black crocodile clips · 1 earthing stake · 1 adapter for mains power socket · 1 male plug adapter for B22 bayonet socket · 1 male plug adapter for E27 screw socket · 1 x 9 V 6LR61 battery · 6 x 1.5 V LR03 batteries SPECIFICATIONS Frequency of signal emitted External voltage measurement Dimensions Weight CA 6681 E 125 kHz 12~300 Vdc / ac (50~60 Hz) 190 × 89 × 42.5 mm Approx. 420 g with battery Detection depth Identification of mains voltage Dimensions Weight CA 6681 R Single-pole application: 0 to 2 m approx. Two-pole application: 0 to 0.5 m approx. Simple looping line: up to 2.5 m 0~0.4 m approx. 241.5 × 78 × 38.5 mm 360 g approx. with battery ADDITIONAL INFO · Automatic or manual adjustment of signal reception sensitivity · The transmitter and receiver units are equipped with: - A battery status indicator - An additional lighting system (torch) for use in dark environments ACCESSORIES / REPLACEMENT PARTS 33 m reel of green wire with battery clip / 4 mm male banana on winder with handle See all the accessories on page 82 P01295268 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 373 ELECTRICAL SAFETY > DATA PROCESSING SOFTWARE > DATAVIEW® DATAVIEW® REF.: P01102095 ICT MEG GTT GTC MOT DTR MTT Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology ICT REPORTS ACCORDING TO THE APPLICABLE STANDARDS The ICT module of DataView® proposes to define the tree-structure which will be used during the actual test campaign (sites, parts, objects), as well as the tests to be performed for each of them. Once defined in this way, the campaign can be recorded in the instrument via the communication link. This saves significant time in the field. FUNCTIONS · Configuration of all the functions of instruments connected to a PC or via Bluetooth · Recovery of the recorded measurement data · Backup of measurement files · Opening of saved files · Processing and creation of reports · Export into an Excel spreadsheet · Export in .pdf format · Database management · Remote test activation by simply pressing a button · Data capture and display in real time · Display of DAR, PI and DD ratios · Graphical plotting of programmed-duration tests and voltage ramp tests in real time · Possibility of creating a library of configurations for specific applications · Printing of measurement reports REQUIRED CONFIGURATION · Windows Vista & Windows 7 / 8 / 10 (32 / 64 bit) · 1 GB RAM for Windows Vista & Windows 7 / 8 (32 bit) · 2 GB RAM for Windows Vista & Windows 7 / 8 (64 bit) · 80 MB disk space available (200 MB recommended) ADDITIONAL INFO · The Dataview® software: · Automatically recognizes the instrument connected when it is hooked up to the PC and opens the corresponding menu. Users then have direct access to the configuration and the recorded data · Is equipped with a large number of predefined report templates for quick generation in compliance with the applicable standards. Users can also create their own templates, as required, and directly add their own comments. DataView® modules ICT MEG GTT GTC CA 6116N CA 6543 CA 6470N CA 6417 CA 6117 CA 6547 CA 6471 CA 6549 CA 6472 Related products CA 6550 CA 6474 CA 6555 CA 6526 CA 6532 CA 6534 MOT DTR MTT* CA 6240 DTR 8510 CA 6161 CA 6255 CA 6163 CA 6292 * available soon 742 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > DATA PROCESSING SOFTWARE > DATAVIEW® MODULE MEGGraphical plotting of the V(t) and R(t) tests on non-linear insulation resistance MODULE MEG G raphical plotting of the V(t) and R(t) tests on fixed insulation resistance (surge suppressor) MOT MODE Results of motor winding test GTT MODULE Example of configuration DTR MODULE Recovery of the measurement data recorded in the ratiometer TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 375 ELECTRICAL SAFETY > ACCESSORIES FOR MULTIFUNCTION INSTALLATION TESTERS ACCESSORIES FOR MULTIFUNCTION INSTALLATION TESTERS MEASUREMENT LEADS AND SENSORS POWER SUPPLY / BATTERIES Accessories Included in the initial delivery Article code Description P01295398 2.5 m three-point lead with separate wires HX0300 Three-point Euro cable P01295393 Three-point cable for EURO mains socket test P01295094 2 elbowed-straight safety leads - (red and black) 3 m long P01101921 3 x Ø 4 mm test probes - (red, blue and green) P01101922 3 crocodile clips (red, blue and green) P01102092A CA 6116N remote-control probe P01102157 CA 6131 - CA 6133 remote-control probe P01101943 Spare black test probe for remote-control probe P01120335 C177 clamp (20 A) P01120336 C177A clamp (200 A) P01120460 MN77 clamp (20 A) P01120439 MN73A clamp P01120421 MN73 clamp P01102057 PA 30 W mains power pack P01102129 Type-2 power pack / charger without mains lead (requires P01295174) P01296024 NiMH 4AH battery pack P01296047 Li-Ion battery pack P01102130 Li-Ion charging support without mains lead P01295174 EURO 2P mains lead HX0061 DC / DC vehicle cigarette-lighter charger P01102186 Type-R USB charger P01102084A Continuity rod P01102017 15 m earth kit (red / blue / green) P01102018 Black 30 m 1P earth kit P01102021 3P earth kit (50 m) P01102022 3P earth kit (100 m) P01298081 4-point hands-free strap (Model 2) P01298057 Hand strap P01102094 CA 6116 screen protection film P01298056 Carrying bag no. 22 P01295293 USB-A USB-B lead P01102095 DataView® software P01298082 Comfort strap HX0302 4-point strap CA 6113 CA 6116N CA 6117 CA 6131 CA 6133 MISCELLANEOUS 762 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > MEASUREMENT LEADS FOR INSULATION TESTERS MEASUREMENT LEADS FOR INSULATION TESTERS 5 KV RANGE Accessories Included in the initial delivery Article code Description Length P01295231 Red simplified HV safety lead / black with rear connection 3 m CA 6505 CA 6545 CA 6547 CA 6549 CA 6550 CA 6555 P01295232 Blue simplified HV safety lead + blue crocodile clip 3 m P01295516 Blue guarded HV safety lead with rear connection 0.35 m P01295510 + P01295506 + P01295513 Set of 3 safety leads with HV crocodile clip (red / blue / black) 3 m P01295507 Safety lead with blue HV crocodile clip 8 m P01295511 Safety lead with red HV crocodile clip 8 m P01295514 Safety lead with rear connection and black HV crocodile clip 8 m P01295508 Safety lead with blue HV crocodile clip 15 m P01295512 Safety lead with red HV crocodile clip 15 m P01295515 Safety lead with rear connection and black HV crocodile clip 15 m Set of 3 red, blue and black P01295465 simplified HV safety leads with 3 m rear connection P01295517 + Set of 3 safety leads with red P01295520 + / blue / black HV crocodile clip 3 m P01295523 with rear connection P01295526 Blue guarded HV safety lead with rear connection 0.5 m P01295521 Safety lead with blue HV safety lead 8 m P01295518 Safety lead with red HV crocodile clip 8 m P01295524 Safety lead with rear connection and black HV crocodile clip 8 m P01295522 Safety lead with blue HV crocodile clip 15 m P01295519 Safety lead with red HV crocodile clip 15 m P01295525 Safety lead with rear connection and black HV crocodile clip 15 m 10 / 15 KV RANGE TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 377 ELECTRICAL SAFETY > CONTENTS OF THE EARTH AND RESISTIVITY KITS CONTENTS OF THE EARTH AND RESISTIVITY KITS 1P kit Article code P01102018 P01102020 P01102017 P01102021 P01102022 P01102023 P01102040 P01102024 P01102025 P01102030 To order Description Black 30 m 1P earth kit Contents of the earth and resistivity kits Recommended related products Reels and winders Other accessories Installation testers 3P 3 / 4P+ Expert Green Red CA CA CA Blue Black Stake(s) / mallet Spade lug / banana adapter Carrying CA 6116N 6422 6460 CA CA CA bag 6113 CA CA CA 6470N 6471 6472 6117 6424 6462 Pylon CA 6474 33 m 1 / - 33 m 1P loop kit 3 33 m 1 / - 15 m 3P earth kit (red / green / blue) 5 m 15 m 10 m 2 / - 50 m earth kit for 3P method 10 m 50 m 50 m 2 / 1 5 Standard 100 m earth kit for 3P method 10 m 100 m 100 m 2 / 1 5 Standard 166 m earth kit for 3P method 10 m 166 m 166 m 2 / 1 5 Prestige 50 m 4P earth & resistivity kit 33 m 50 m 50 m 33 m 4 / 1 100 m earth & resistivity kit 166 m earth & resistivity kit 100 m 10 m 100 m 100 m 33 m 4 / 1 100 m 10 m 166 m 166 m 33 m 4 / 1 100 m add-on for resistivity 100 m 33 m 2 / - 5 Standard 5 Prestige 5 Prestige Standard 3P kit 4P kit Comp. OTHER ACCESSORIES Article code P01102026 Description Green cable H winder1 Reels and winders Green Red Blue Black 10 m P01102028 Set of 4 adapters for terminals3 P01102029 Set of 4 reel handles P01102031 T-shaped earth stake P01102046 Set of 3 adjustable clamps P01102047 H-shaped black cable winder - 10 m1 10 m P01120310 C172 clamp P01295260 166 m red cable reel1 166 m P01295261 100 m red cable reel1 100 m P01295262 50 m red cable reel1 50 m P01295263 166 m blue cable reel1 166 m P01295264 100 m blue cable reel1 100 m P01295265 50 m blue cable reel1 50 m P01295266 100 m green cable reel1 100 m P01295267 33 m black cable reel1 33 m P01295268 33 m green cable reel1 33 m P01295270 2 m black cable winder (2 m cable for clamps)1 2 m* P01295291 5 m green cable H winder2 5 m P01295292 5 m black cable H winder2 5 m 1 connections: spring clip - banana 2 connections: banana - banana 3 for CA 6030 * for CA 6470N and CA 6471 Article code Description CA 647x continuity kit (4 red, black, blue and yellow P01102037 crocodile clips), (2 black test probes), (4 red, black, blue and yellow cables 1.5 m long) 5 m AmpFlexTM P01120550 flexible current sensors 8 m AmpFlexTM P01120551 flexible current sensors Set of 3 P01102046 adjustable clamps P01120310 C172 clamp 3 P01120335 C177 clamp P01120336 C177A clamp P01120333 C182 clamp P01120872 G72 clamp (CA 6424) ADDITIONAL INFO Possibility of ordering carrying bag: · Standard version....................... P01298066 · Prestige version........................ P01298067 782 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > ACCESSORIES FOR ELECTRICAL EQUIPMENT TESTERS ACCESSORIES FOR ELECTRICAL EQUIPMENT TESTERS Accessories Included in the original delivery Article code Test and measurement lead Description P01295097 4 mm banana cable- red + black Length CA 6161 CA 6163 CA 6121 CA 6155 CA 6160 CA 6165 3 m P01295137 Double crocodile cable black P01295140 Double crocodile cable red P01295141 Discharge cable (EURO) P01295236 Double continuity cables P01295234 Power cable (EURO) HV test gun and probe P01102139 P01102136 P01102137 P01102138 P01102140 P01102141 P01102142 P01102143 P01102144 P01102145 P01101919 Red test lead Plug-in test cable Test cable with separate wires Black + red test lead Green test lead Black test probe for CA 6155 Red test probe for CA 6155 Green test probe for CA 6155 Blue test probe for CA 6155 Set of 3 black crocodile clips HV test gun P01102135 HV test probe for CA 6155, for P01146001 P01102193 P01102195 P01101918 P01102182 Remote control, indication and communication Set of 2 HV test guns - 3 m Set of 2 HV test guns - 15 m HV test gun HV test gun (set of 2) P01101916 Remote-control pedals 2.5 m 2.5 m 2 m 2.5 m 2 m 4 m 1.5 m 3 m 1.5 m 1.5 m 2 m 6 m 2 m P01101917 P01102191 P01102192 P01101841 P01295172 P01295173 Red / green indicator lamps Remote-control pedal -3 4-lamp tower - 2 DB9F-DB25M adapter DB9F-25F cable x2 DB9F-DB9M cable no. 1 P01102177 P01102178 P01102179 Control pedal 2-colour indicator lamp 4-colour indicator lamp Fuses P01102180 P01101915 P01101996 Power supply adapter for lamps MachineLink software with communication cables CALink software MTLink software CELink software with communication cables P01297086 P01297102 P01297103 F 6x32T 16 A 250 V (set of 10 fuses) F 6x32T 16 A 500 V (set of 10 fuses) F 5x20T 5 A 250 V (set of 10 fuses) TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 379 ELECTRICAL SAFETY > ACCESSORIES FOR OTHER TESTERS ACCESSORIES FOR OTHER TESTERS Accessories Included in the original delivery Article code Description Double test probes and Kelvin clamps for micro-ohmmeters Connections CA 6161 CA 6163 CA 6240 CA 6255 CA 6292 DTR 8510 CA 6681 CA 6630 P01101794 10 A Kelvin clamps (set of 2), L=3 m Spade lug Other accessories P01101783 1 A Kelvin mini-clamps (set of 2) Spade lug P01102056 1 A double test probe (set of 2) L=2.85 m Spade lug and 4 mm banana P01103065 10 A double gun-type test probe Spade lug and (set of 2) L= 3.15 m 4 mm banana P01103063 10 A double pivoting test probe Spade lug and (set of 2) L= 3.15 m 4 mm banana P01295486 P01295487 P01295494 P01295495 Set of 2 Kelvin leads 6 m long (red / black) with adjustable-clamp connections Set of 2 Kelvin leads 15 m long (red / black) with adjustable-clamp connections Set of 2 leads 6 m long with 200 A Kelvin clamps Set of 2 leads 15 m long with 200 A Kelvin clamps P01101784 1 x 25 A Kelvin crocodile clip P01102199 1 x 25 A Kelvin test probe 3 m long P01102200 1 x 25 A Kelvin test probe 6 m long P01295488 Green earth lead with crocodile clip P01120470 MR6292 clamp P01102013 CT 100 probe P01102201 Set of 3 Input / Output connectors P01102202 Three-phase / 16 A Banana adapter P01120872 G72 clamp Measurement lead for ratiometer P01295143A Set of 2 spare leads, primary H, secondary X L= 4.6 m , compatible with DTR 8500 / DTR 8510 4 mm banana Adapters for cable and metal conductor locator Kit of 3 measurement adapters P01102114Z for housing (B22, E27, mains socket) B22 bayonet E27 screw socket 2P mains socket Measurement lead for battery capacity tester Set of 2 double-contact current P01102103 / voltage measurement leads for Jack CA 6630 battery tester. L=1 m 802 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > ACCESSORIES / REPLACEMENT PARTS ACCESSORIES / REPLACEMENT PARTS INSTALLATION TESTERS CA 6011 · Cable reeler no. 1 - 30 m..............................P01295492 · 1 waist belt + 1 shoulder strap.....................P01102171 · 30 m cable for reeler....................................P01295493 · 2 elastic straps.............................................P01102172 · 1 set of replacement accessories..................P01102173 · Continuity rod...............................................P01102084A CA 6030 · C172 current clamp......................................P01120310 · C176 clamp..................................................P01120330 · MN20 current clamp....................................P01120440 · Series printer no. 5.......................................P01102903 · 1P loop kit....................................................P01102020 · 3 crocodile clips (red / white / yellow).....................................P01101905 · 3 test probes (red / white / yellow)................P01101906A · Optical / RS232 connection cable.................P01295252 · 10 m green cable H winder...........................P01102026 · T earth stake................................................P01102031 · 100 m reel of green cable.............................P01295266 · 33 m reel of green cable...............................P01295268 · Standard bag no. 5........................................P01298066 CA 6131, CA 6133 · Remote-control probe no. 4..........................P01102157 · Three-pole EURO cable................................HX0300 · Neck strap....................................................HX0302 · Continuity rod...............................................P01102084A · Test probes (red + black)..............................P01295454Z · Crocodile clips (red + black).........................P01295457Z · 2 cables 1.5 m long (red / black)...................P01295450Z · Yellow bag no. 2............................................P01298006 CA 6131 · MN73 clamp................................................P01120421 · 1.5 V LR6 alkaline battery.............................P01296033 CA 6133 · MN73A clamp...............................................P01120439 · Type R USB charger.......................................P01102186 · 4 x 1.2 V NiMh 2.4 AH AALSD batteries..........HX0051B · 15 m basic earth kit (yellow, green, red)........................................P01102019 · 50 m earth kit...............................................P01102021 INSULATION TESTERS CA 6501 and CA 6503 · Bag no. 2......................................................P01298006 · CA 1246 thermo-hygrometer.........................P01654246 · CA 1821.......................................................P01654821 · 0.2 A / HRC fuse for CA 6501........................P01297095 · 2 crocodile clips (red / black).........................P01295457Z · 2 test probes (red / black)..............................P01295458Z · 2 leads 1.5 m long (red / black).....................P01295289Z · 3 crocodile clips (red, black, blue)...................P01103062 · 3 safety leads 1.5 m (red, black, blue)...........................................P01295171 CA 6511 and CA 6513 · CA 1246 thermo-hygrometer.........................P01654246 · CA 1821.......................................................P01654821 · 2 crocodile clips (red / black).........................P01295457Z · 2 test probes (red / black)..............................P01295454Z · 2 leads 1.5 m long (red / black).....................P01295289Z · 1.5 V LR6 battery..........................................P01296033 · 1.6 A fuse.....................................................P01297022 · Shockproof sheath no. 13..............................P01298016 CA 6522, CA 6524, CA 6526, CA 6532, CA 6534 and CA 6536 · Remote-control probe....................................P01101935A · CA 1246 thermo-hygrometer.........................P01654246 · CA 1821.......................................................P01654821 · Hands-free bag.............................................P01298049 · 1.5 V LR6 battery..........................................P01296033 · Test probes (red + black)...............................P01295454Z · Crocodile clips (red + black)..........................P01295457Z · Elbowed-straight safety leads (red + black) 1.5 m long................................P01295453Z · DataView® software.......................................P01102095 CA 6528 · CA 1246 thermo-hygrometer.........................P01654246 · CA 1821 thermometer...................................P01654821 · 1.5 V LR6 battery..........................................P01296033 · Test probes (red + black)...............................P01295454Z · Crocodile clips (red + black)...........................P01295457Z · Elbowed-straight safety leads (red + black) 1.5 m long................................P01295289Z CA 6541 and CA 6543 · Remote-control probe....................................P01101935 · CA 1246 thermo-hygrometer.........................P01654246 · CA 1821.......................................................P01654821 · AN1 artificial neutral box................................P01197201 · Bag no. 6 for accessories..............................P01298051 · 1.5 V LR14 battery........................................P01296034 · Fuse F 2.5 A - 1.200 V - 8 x 50 mm - 15 kA (x 5)................................P01297071 · Fuse F 0.1 A - 660 V - 6.3 x 32 mm - 20 kA (x 10)...................................P01297072 CA 6543 · Series printer no. 5........................................P01102903 · Series-parallel adapter...................................P01101941 · DataView® software.......................................P01102095 · 1.5 m safety leads (red, blue, black)...............P01295171 · RS232 PC DB 9F - DB 25F cable x 2..............P01295172 · RS 232 printer DB 9F - DB 9M cable no. 01.................................................P01295173 · European 2P mains lead................................P01295174 · UK mains lead...............................................P01295253 · Battery pack.................................................P01296021 CA 6505, CA 6545, CA 6547 and CA 6549 · CA 1246 thermo-hygrometer.........................P01654246 · CA 1821.......................................................P01654821 · AN1 artificial neutral box................................P01197201 · Standard bag for accessories.........................P01298066 · Fuse FF 0.1 A - 380 V - 5 x 20 mm - 10 kA (x 10)..............................P03297514 · European 2P mains lead................................P01295174 CA 6547 and CA 6549 · Series printer no. 5........................................P01102903 · Series-parallel adapter...................................P01101941 · DataView® report generation software............P01102095 · RS 232 PC DB 9F - DB 25F cable x 2.............P01295172 · RS 232 printer DB 9F - DB 9M cable no. 01.................................................P01295173 CA 6550 and CA 6555 · 2 red / black test probes................................P01295454Z · 3 red / blue / black crocodile clips..................P01103062 · USB optical cable..........................................HX0056-Z · Shoulder bag................................................P01298066 · CA 1246 thermo-hygrometer.........................P01654246 · CA 1821.......................................................P01654821 · European 2P mains lead................................P01295174 CLAMP MULTIMETERS FOR LEAKAGE CURRENT F65 · Red / black crocodile clamps (set of 2)...........P01295457Z · Elbowed test-probe leads, 1.5 m, (1 red / 1 black)...P01295456Z · Soft case 200 x 100 x 40 mm with belt clip......P01298065Z · CMI214S current measurement lead..............P03295509 · Shoulder bag no. 21 (250 x 165 x 60 mm) with strap.....................P06239502 EARTH AND RESISTIVITY TESTERS CA 6421 and CA 6423 · Carrying strap...............................................P01298005 · Fuse HRC 0.1 A - 250 V (x 10).......................P01297012 · 1.5 V LR06 battery........................................P01296033 · Shoulder bag no. 2........................................P01298006 CA 6422 and CA 6424 · 15 m earth kit (blue / green / red)..................P01102017 · 50 m expert earth kit.....................................P01102021 · Carrying bag.................................................P01298006 · 4-point hands-free strap................................HX0302 CA 6422 · 1.5 V LR6 battery..........................................P01296033 CA 6424 · 4 x1.2 V NiMh 2.4 AH AALSD batteries...........HX0051B · Type-R USB charger......................................P01102186 · G72 current clamp........................................P01120872 CA 6416 and CA 6417 · DataView® software.......................................P01102095 · Bluetooth / USB modem.................................P01102112 · Hard case.....................................................P01298080 · CL1 calibration loop.......................................P01122301 CA 6418 · CL1 calibration loop.......................................P01122301 · MLT110* carrying case..................................P01298080 · 1.5 V LR6 alkaline battery..............................P01296033 *Requires 2 X convoluted foam inserts 691714A00 CA 6460 and CA 6462 · European 2P mains lead................................P01295174 · Fuse HRC 0.1 A - 250 V (x 10).......................P01297012 · Battery pack.................................................P01296021 · 1.5 V LR06 battery........................................P01296033 · Standard bag................................................P01298066 CA 6470N, CA 6471 and CA 6472 · DataView® report generation software............P01102095 · Adapter for battery charging on vehicle cigarette lighter.............................P01102036B · Optical / RS communication cable..................P01295252 · UK mains lead...............................................P01295253 · Set of 10 fuses: F 0.63 A - 250 V - 5 x 20 mm - 1.5 kA..........AT0094 · Adapter for battery charging on the mains supply......................................P01102035 · Battery pack.................................................P01296021 · Optical / USB communication cable................HX0056-Z CA 6471 and CA 6472 · MN82 clamp (diam. 20 mm) delivered with 2 m cable for connection to ES terminal..........P01120452 · C182 clamp (diam. 52 mm) delivered with 2 m cable for connection to ES terminal..........P01120333 · Standard bag................................................P01298066 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 381 ELECTRICAL SAFETY > ACCESSORIES / REPLACEMENT PARTS ACCESSORIES / REPLACEMENT PARTS CA 6474 · Connection cable..........................................P01295271 · 15 m BNC / BNC cable..................................P01295272 · 5 m AmpFlex® flexible current sensor.............P01120550 · 8 m AmpFlex® flexible current sensor.............P01120551 · Set of 12 identification rings for AmpFlex®......P01102045 · Set of 3 adjustable clamps.............................P01102046 · 5 m green cable (E terminal connection).........P01295291 · 5 m black cable (E terminal connection)..........P01295292 · Spade lug / banana plug adapter....................P01102028 · Calibration loop.............................................P01295294 · Prestige bag.................................................P01298067 ELECTRICAL EQUIPMENT TESTERS CA 6121 · Machine Link Windows processing software (supplied with communication cable)..............P01101915 · Series printer no. 5........................................P01102903 · DB9F-DB25M adapter...................................P01101841 · Remote-control pedal....................................P01101916 · Indicator lamps (green / red)..........................P01101917 · Roll of paper for series printer (set of 5)..........P01101842 · 2 crocodile clips (red / black).........................P01295457Z · 2 test probes (red / black)..............................P01295458Z · 2 dielectric test guns with 6 m cable..............P01101918 · 2 dielectric test guns with 2 m cable..............P01101919 · 2 safety leads 3 m long (red / black)...............P01295097 · Continuity test lead 2.5 m long (black)............P01295137 · Continuity test lead 2.5 m long (red)...............P01295140 · Discharge-time cable (European)....................P01295141 CA 6155 · 4 m red test lead...........................................P01102139 · Red + black 1.5 m test lead..........................P01102138 · Red 1.5 m test lead.......................................P01102140 · 1.5 m plug-in test cable................................P01102136 · 3 m test cable with separate wires.................P01102137 · Black test probe............................................P01101141 · Red test probe..............................................P01102142 · Green test probe...........................................P01102143 · Blue test probe..............................................P01102144 · Set of 3 black crocodile clips..........................P01102145 · Set of 10 fuses: 16 A-250 V 6 x 32 T.............P01297086 · Set of 2 HV cables.........................................P01103071 · HV crocodile clip...........................................P01103072 · HV test probe................................................P01103073 CA 6165 · 1 remote-control pedal (type 2)......................P01102177 · 2-lamp tower (red / green).............................P01102178 · 4-lamp tower (red / green / blue / orange)......P01102179 · Lamp power supply adapter...........................P01102180 · 2 x 2 m HV guns...........................................P01102182 · 2 x 3 m cables (red / black)...........................P01295097 · EURO discharge cable...................................P01295141 · 1 double continuity cable...............................P01295236 · 2 test probes, CAT IV 1kV (red / black)............P01295454Z · 2 crocodile clips, CAT IV 1kV (red / black).......P01295457Z · Time-delay fuse, 6 X 32 mm, 16 A 250 V (x10)......P01297102 · Fuse 5 X 20 mm 5 A 250 V (x10)...................P01297103 · Standard carrying bag...................................P01298066 OTHER TESTERS CA 6240 and CA 6255 · 1 A double test probe (x 2).............................P01102056 · Mini Kelvin clamp (set of 2)............................P01101783 · UK mains lead...............................................P01295253 · CA 1846 thermo-hygrometer.........................P01654246 · European 2P mains lead................................P01295174 · Standard bag................................................P01298066 · 10 A-P clamp (set of 2)..................................P01101794 · DataView®....................................................P01102095 · Straight probe with 10 A double pivoting retractable test probe (x 2).............................P01103063 · Gun with 10 A double retractable test probe (x 2)..............................................P01103065 CA 6240 · Set of 10 fuses: 6.3 x 32 / 12.5 A / 500 V..............P01297091 · Optical / USB communication cable........................HX0056-Z CA 6255 · Pt 100 temperature sensor....................................P01102013 · 2 m cable for remote Pt 100..................................P01102014 · RS 232 PC DB 9F DB 25F cable x 2....................P01295172 · Set of 10 fuses: 6.3 x 32 / 16 A / 250 V.................P01297089 · Set of 10 fuses: 5.0 x 20 / 2 A / 250 V...................P01297090 CA 6292 · 1 set of 2 Kelvin leads 6 m long (red / black) with adjustable-clamp connections.........................P01295486 · 1 set of 2 Kelvin leads 15 m long (red / black) with adjustable-clamp connections.........................P01295487 · 1 green earth lead with crocodile clip.....................P01295488 · 1 set of 5 fuses: T1 5 A 250 V 5x20 mm................P01297101 · 1 USB-A USB-B cable 1.5 m long...........................P01295293 · 1 MR6292 clamp..................................................P01120470 · Set of 2 leads 6 m long with 200 A Kelvin clamps..............................................P01295494 · Set of 2 leads 15 m long with 200 A Kelvin clamps..............................................P01295495 · Standard carrying bag...........................................P01298066 DTR 8510 · Set of 2 replacement leads 4.6 m long...................P01295143A · Set of 2 replacement leads 10 m long....................P01295145 · USB cable.............................................................P01295293 · Shoulder bag........................................................P01298066 CA 6681 · 33 m reel of green wire, battery clip / 4 mm male banana on winder with handle................P01295268 · 10 m reel of green wire, battery clip / 4 mm male banana on H winder..............................P01102026 · Kit of 3 measurement adapters for housing (B22, E27, mains socket)...............................P01102114Z CA 6630 · Set of 2 leads with retractable test probes......P01102103 See all our accessories on page 150 822 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > NOTES NOTES TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 383 POWER QUALITY & INSTALLATION MONITORING > INFO AND ADVICE > ELECTRICAL INSTALLATION TESTING INFO AND ADVICE 84 POWER AND HARMONICS CLAMPS 86 POWER AND ENERGY QUALITY ANALYSERS 88 ELECTRICAL MEASUREMENT LOGGERS 94 DATA PROCESSING SOFTWARE 102 ACCESSORIES 104 POWER AND DISTURBANCES A phase of analysis is essential to precisely identify the behaviour of the installations and determine which solutions to implement. The measurements made help to ensure that the solutions are pertinent and that the gains achieved are maintained over the long term in the context of an energy optimization programme. So measurement provides the foundation for optimizing your installations' energy efficiency, supervising your electrical networks and fairly allocating the costs. POWER MEASUREMENTS Power measurement is a key element for the definition, success and long-term effects of an energy optimization programme. Reducing electricity consumption is also a simple, painless way of saving money. Electricity is a clean energy source which is less harmful for the environment, but it does affect it nevertheless. The various parameters of the installation are measured regularly, including the different power values used to size the electrical network and the phase shift data, as well as the voltage, current and frequency measurements. For private customers, reactive power is neither measured nor billed separately. Instead is it included at a flat rate in the active power price. Things are very different for industrial customers, however. Electricity suppliers penalize consumers whose displacement power factor (cos phi or DPF) is lower than 0.93 (in France) or whose tan phi is higher than 0.4 (in France). This set of measurements will help the installation manager to size the capacitor banks correctly. Today, the IEEE1459 standard defines a measurement method for all the different power values. Thus, to compensate the phase shift, you can measure the fundamental reactive power Q1, which simplifies sizing of the capacitor bank required. TROUBLESHOOTING DISTURBANCES With the spread of systems incorporating electronics using switching power supplies, the electrical network is becoming increasingly polluted. A further complication is the fact that electricity market deregulation could lead to more frequent general network blackouts. The quality requirements have become much more demanding and stringent than in the past. All the equipment in factories and buildings now includes digital electronics which are known to be sensitive to micro-outages, peaks and dips, harmonics and disturbances in general. IEC 61000-4-30 Today, there is uniformization of the measurement methods used to troubleshoot disturbances so that the results can be compared. The IEC 61000-4-30 standard defines the measurement methods for energy quality measuring instruments, the time aggregation specifications and the minimum accuracy applicable to each energy quality parameter to obtain reliable, comparable results. these measurement methods are checked using tests described by the IEC 62586 standard. Depending on the measurement method used (the standard authorizes certain choices) and the accuracy provided by the instrument, the instrument will be assigned to one of several categories: Class A, S or B. Class A instruments require regular, precise time resynchronization. Harmonics and interharmonics The complexity of industrial equipment makes it vulnerable to the voltage disturbances that occur on the electrical network. The arrival of new quick-switching components is leading to a large number of low-order harmonic currents (3, 5, 7, 9, 11, ...). The waveform of the current consumed by loads connected to the electrical network is often no longer purely sinusoidal. This current distortion implies distortion of the voltage which also depends on the impedance of the source. The disturbances called harmonics are caused by connecting non-linear loads, such as equipment incorporating power electronics, to the network. This may have instant consequences on certain electronic equipment: operating problems (synchronization, switching), untimely tripping, measurement errors on energy meters, etc. In the medium term, the extra heating caused by this may reduce the life span of rotating machines, capacitors, power transformers and neutral conductors. Today's measuring instruments have to be capable of performing this harmonic analysis order by order, as well as measuring the Total Harmonic Distortion (THD) for more detailed diagnosis of the installation. Variations Some types of faults are encountered very frequently. In general, the main types of disturbances involve: · Slow voltage variations and transients The voltage amplitude is a crucial parameter for electricity quality. The voltage amplitude varies abnormally and may even drop to a level close to zero. The causes mainly lie in the installation itself. The connection of heavy loads may lead to voltage variations if the short-circuit power at a point of supply is undersized. Several types of faults are then defined: overvoltage, voltage dip, outage, etc. The rated network voltage variation range is set by the power distributor. · Flicker: rapid voltage fluctuations When variable loads such as arc furnaces, laser printers, microwave ovens or air-conditioning systems are started up, they cause rapid voltage variations. This phenomenon is called flicker. In reality, the flicker value is the result of a statistical calculation based on measurements of the rapid voltage variations. A 10-minute interval is considered an acceptable compromise for evaluation of the short-term flicker (Pst). If the combined effect of several disturbance-generating loads operating in a random way (e.g. welding units or motors) has to be taken into account or when flicker sources with long or variable operating cycles are involved (electric arc furnace), the resulting disturbance must be assessed over a longer time. The measurement duration defined is then 2 hours, a time considered appropriate for the load operating cycle or the time during which an observer may be sensitive to long-term flicker (Plt). The instruments used to analyse electrical networks and record disturbances for the industries and processionals in the electrical sector (generators, transmission companies, electricity users) are essential tools for monitoring and timely installation of installations. They must provide direct measurement, allow the maximum possible parameterization and permit subsequent analysis. 842 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com POWER QUALITY & INSTALLATION MONITORING > INFO AND ADVICE > POWER AND ENERGY POWER QUALITY & INSTALLATION MONITORING DATA LOGGING MADE SIMPLE FOR ECONOMICAL, SUSTAINABLE BUILDINGS, IMPROVE YOUR ENERGY EFFICIENCY In the context of a worldwide drive to protect the environment, many countries have set targets for reducing their energy consumption. Today, more than 50% of energy consumption occurs in industry and in buildings. Energy consumption therefore needs to optimized to meet the regulatory requirements. There are rules imposing tests and improvements with regard to energy consumption. By analysing the structure (building, insulation, etc.), users can control passive energy efficiency. Then, by using high-performance instruments and smart measuring and control systems (variable speed drives or load-shedding devices), it will be possible to adjust the operating conditions and thus, more generally, the active energy efficiency. THE EN 16247 STANDARD The EN 16247-1 standard defines the general methodological and quality requirements for preparation, execution and reporting of the audit. These methods are defined according to the activity audited: · for buildings: EN 16247-2 · for industrial processes: EN 16247-3 · for transport: EN 16247-4 In all cases, measurement campaigns are necessary to check the efficiency of the equipment, the periods when it is used and the real condition of the building shells. The data loggers family is a product line with a wide range of applications. They are suitable for: ·electrical installations, whether involving three-phase power or lower, ·multifunction requirements, or highly accurate measurements for a sector A full set of alarm programming tools allows you to program alarm set points and triggering on high or low thresholds, or inside or outside a predefined range. When connected to a communication network, you can be immediately informed about this alarm by email. Low-consumption technologies or solutions powered directly via the measurement channels give these instruments the necessary autonomy for effective recording campaigns. All these measuring solutions are naturally now compatible with complementary software tools. They will also be the interface for remote tests or data downloading. APPLICATIONS N eutral current monitoring to detect unwanted leakage currents Real-time current harmonics monitoring to locate unwanted energy which causes equipment failure Load profiling which sizes loads to optimize transformer and meter selection Split-phase load monitoring for residential voltage and current M achine load monitoring detects overload conditions causing premature equipment failure due to overheating Process loop monitoring can detect problematic sensors and control systems HVAC and general temperature profiling (refrigeration and air-conditioning systems) TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 385 POWER QUALITY & INSTALLATION MONITORING > POWER ANALYSERS / CLAMPS > SELECTION GUIDE CHOOSE YOUR POWER ANALYSER / CLAMP Display Analogue Digital Graphical No. of inputs Current Voltage DPF PF AC DC Range AC DC F407 page 87 1U/1I 1,000 A 1,000 V 1,000 V Harmonics THD/orders Power Data storage Internal SD card Recording Trend Alarms Transients Images Inrush Surge Monitoring Standards IEC61010 IEC61000-4-30 IEC 60529 Temperature Resistance Rotation speed Unbalance /25 PQS 1000V CAT IV IP54 Flicker Communication USB Wifi Bluetooth Ethernet / IRD server Power supply Batteries Mains Rechargeable batteries Power supply via the phase F607 page 87 CA 8220 page 87 CA 8331 page 88 CA 8333 page 89 CA 8336 page 90 CA 8436 page 91 CA 8345 page 92 1U/1I 1U/1I 3U/3I 3U/3I 4U/4I 4U/4I 4U/4I 2,000 A 1,000 V 1,000 V Depending on sensor Depending on sensor Depending on sensor Depending on sensor Depending on sensor Depending on sensor 600 V 600 V 1,000 V 1,000 V 1,000 V 1,000 V 1,000 V 1,000 V 1,000 V 1,000 V 1,000 V 1,000 V /25 /50 /50 /50 /50 /50 /63 PQS PQS PNQ1DS PNQ1DS PNQ1DS PNQ1DS PNQ1DS 99 12 1000V CAT IV 600V CAT III IP54 IP54 IP53 80 µs 12 80 µs 50 600V CAT IV - 1000 V CAT III Class B IP53 IP53 80 µs 50 Class B IP67 2.5 µs 12kV EN50160 1000V CAT IV Class A IP54 PST PST PST/PLT PST/PLT PST/PLT / Opt. Opt. Opt. Integrated Opt. 862 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com POWER QUALITY & INSTALLATION MONITORING > POWER AND HARMONICS CLAMPS | POWER ANALYSER > F407 - F607 | CA 8220 F407 - F607 REF.: P01120947 REF.: P01120967 CA 8220 REF.: P01160620 Diagnostics & testing Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Measurements up to 2,000 Aac or 3,000 Adc or Aac+dc · Clamping Ø 60 mm · Harmonic analysis up to the 25th order · TrueInrush function · 3-year warranty 1000 V IP CAT IV 54 Ø 2000 60 mm AAC Diagnostics & testing Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology MOTOR MAINTENANCE 600 V IP CAT III 54 STRENGTHS · Access to all the measurements simultaneously · Low resistance and high current measurements · Motor temperature measurement · Motor rotation speed SPECIFICATIONS Current (RMS) AC DC and AC+DC Best accuracy Voltage (RMS) AC DC and AC+DC Best accuracy Auto AC/DC Resistance Continuity/buzzer Power W (P), var (Q1), VA (S) Crest factor (CF) PF and cos (DPF) Auto power-off Hold function Backlighting function Min Max key Peak +/- 100 ms function True Inrush function THD-f / THD-r harmonics function Decomposition into harmonic orders REC storage function Recordings (with Min, Max) Bluetooth communication function Frequency Clamping diam. Protection Electrical safety Warranty Dimensions / weight F407 F607 100 mA to 1,000 A 100 mA to 2,000 A 100 mA to 1,500 A 100 mA to 3,000 A 1 % reading + 3 counts 100 mV to 1,000 V 100 mV to 1,000 V 1 % reading + 3 counts Yes (V and A) 100 k Yes (< 40 ) Yes, single-phase and total three-phase Yes Yes / Yes Yes Yes Yes Yes Yes / Yes Yes Yes / Yes 25th Yes Up to 3,000 measurements Yes 15 Hz to 20 kHz 48 mm 60 mm IP 54 IEC 61010 1000 V CAT IV 3 years 272 x 92 x 41 mm 600 g (with batteries) 296 x 111 x 41 mm 640 g (with batteries) CONTENTS F407 and F607 delivered in a bag pre-equipped for MultiFix · 1 set of banana/banana leads (red/black) · 1 set of test probes (red/black) · 1 set of crocodile clips (red/black) · 4 x 1.5 V LR6 batteries · 1 safety datasheet · 1 CD-Rom containing a user manual and the PC data recovery software (Power Analyser Transfer) SPECIFICATIONS Voltage (TRMS) Current (TRMS) MN clamp C clamp AmpFlex® or MiniFlex PAC E3N/E27 Frequency Other measurements Harmonics Sampling rate Recording capacity Power supply Battery life Communication Display Dimensions / weight Electrical safety CA 8220 Phase/Phase: 660 Vac+dc Phase/Neutral: 600 Vac+dc MN93: 2 to 240 Aac ; MN93A: 0.005 Aac to 5 Aac / 0.1 Aac to 120 Aac 3 A to 1,200 Aac 30 A to 6,500 Aac 10 A to 1,000 Aac / 10 A to 1,400 Adc 50 mA to 10 Aac+dc, 100 mA to 100 Aac+dc 40 Hz to 70 Hz W (P), var (Q1), PF, DPF, VA (S), temperature, phase rotation, RPM, resistance, continuity, diode test, Wh, VAh, varh Orders 1 to 50 256 samples/period 99 complete sets of voltage, current, power and harmonics measurements 6 x 1.5 V LR06 batteries, mains power supply option 8 hours with display activated Optical USB 3-display backlit screen with symbols 211 x 108 x 60 mm / 0.88 kg IEC 61010 600 V CAT III, IP 54, pollution degree 2 CONTENTS · CA 8220 · 2 banana leads · 2 x 4 mm test probes · 2 crocodile clips · 6 x 1.5 V LR06 batteries · 1 optical USB cable · Power Analyser Transfer processing software · 1 CD-ROM containing the user's manual ADDITIONAL INFO · The CA 8220 analyser is also available with a current sensor: CA 8220 MN93A...................... P01160621 ACCESSORIES / REPLACEMENT PARTS Set of banana/banana leads (red/black) Set of crocodile clips (red/black) See all the accessories on page 150 P01295451Z P01295457Z ACCESSORIES / REPLACEMENT PARTS CA 1711 tachometric sensor 2-wirePt100 adapter See all the accessories on page 150 P01102082 HX0091 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 387 POWER QUALITY & INSTALLATION MONITORING > THREE-PHASE NETWORK AND POWER ANALYSERS > CA 8331 CA 8331 REF.: P01160511 53 1000 V 600 V 3U IP CAT III CAT IV 4I Diagnostics & testing Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · TRMS AC+DC voltage and current, frequency · Measurements for power surveys · Measurements for sizing the anti-harmonic filters · Simultaneous recording of all the parameters ADDITIONAL INFO ·The Power Analyser Transfer software for recovering the data on your PC is supplied as standard SPECIFICATIONS CA 8331 Number of channels Number of inputs Voltage (TRMS AC+DC) Voltage ratio 3U / 4I 4V / 3I 2 V to 1,000 V up to 500 kV Current (TRMS AC+DC) MN MN93: 500 mA to 200 Aac ; MN93A: 0.005 Aac to 100 Aac C193 AmpFLEX® or MiniFlex PAC93 E3N J93 Current ratio Frequency Power values Energy values Harmonics 1 A to 1,000 Aac 100 mA to 10,000 Aac 1 A to 1,300 Aac/dc 50 mA to 100 Aac/dc 50 A to 3,500 Aac / 50 A to 5,000 Adc Up to 60 kA 40 Hz to 69 Hz W (P), VA (S), var (Q1, N, D), PF, DPF, cos , tan Wh, varh (Q1h, Nh, Dh), VAh Yes THD Flicker Unbalance Min/Maxrecording Yes, orders 0 to 50, phase Pst Yes Yes of a selection of parameters at max. sampling rate From a few hours to several days Peak Yes Vectorial representation Automatic Display Colour ¼ VGA TFT screen; 320 x 240, diagonal 148 mm Screenshots and curves 12 Electrical safety IEC 61010 1 000 V CAT III / 600 V CAT IV Ingress protection IP53 / IK08 Languages More than 27 Communication interface USB Battery life Up to 10 hours Power supply Rechargeable 9.6 V NiMH rechargeable battery or mains power supply Dimensions / weight 240 x 180 x 55 mm / 1.9 kg FUNCTIONS · Real-time display of the waveforms (4 voltage inputs, 3 current inputs) · Measurement of RMS voltages and currents per ½-period · Intuitive use · Automatic recognition of the different types of current sensors · Voltage and current ratios · Mixing of current sensors · Measurement, calculation and display of the harmonics up to the 50th order, along with their phase information · Calculation of the Total Harmonic Distortion (THD) · Display of the phasor diagram · Power measurements: VA, W, VAD, total var and var per phase · Energy measurement: VAh, Wh, VADh, total varh and varh per phase · Calculation of the K factor FHL · Calculation of the displacement power factor cos (DPF) and the power factor PF · Calculation of Flicker PST · Calculation of the unbalance (current and voltage) · Backup and recording of screenshots (image and data) · Recording and export on PC · Real-time PC data recovery and communication software CONTENTS CA 8331 delivered with: · 1 bag No.22 · 1 USB cable · 1 mains adapter · 4 x 3 m voltage cables with 4 mm banana connections · 4 crocodile clips · 1 safety datasheet · 1 set of 12-colour markers for the cables and inputs · 1 scratchproof protective screen film (mounted) · 1 CD-ROM containing the Power Analyser Transfer PC data recovery software Don't forget to order your current sensors too: see page 104 882 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com POWER QUALITY & INSTALLATION MONITORING > THREE-PHASE NETWORK AND POWER ANALYSERS > CA 8333 CA 8333 REF.: P01160541 53 1000 V 600 V 3U IP CAT III CAT IV 4I Diagnostics & testing Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · TRMS AC+DC voltage and current, frequency · Measurements for power surveys · Measurements for sizing the anti-harmonic filters · Recording of all the parameters simultaneously · Capture of all the transients, alarms and waveforms ADDITIONAL INFO · Possibility of Essailec-type current connection FUNCTIONS · Real-time display of the waveforms (4 voltage inputs and 4 current inputs) · RMS voltage and current measurements by the ½-period · Intuitive use · Automatic recognition of the different types of current sensors · Integration of all the DC components · Voltage and current ratios · Mixing of current sensors · Measurement, calculation and display of the harmonics up to the 50th order, along with their phase information · Calculation of the Total Harmonic Distortion (THD) · Capture of transients as short as one sample (1/256th of a period) · Display of phasor diagram · Power measurements: VA, W, VAD, total var and var per phase · Energy measurement: VAh, Wh, VADh, total varh and varh per phase · Calculation of the K factor FHL · Calculation of the Displacement Power Factor cos (DPF) and power factor PF · Capture of up to 50 transients · Calculation of Flicker PST · Calculation of the unbalance (current and voltage) · Electrical network supervision with setting of alarms · Backup and recording of screenshots (image and data) · Recording and export on PC · Real-time PC data recovery and communication software CONTENTS CA 8333 delivered with: · 1 bag No. 22 · 1 USB cable · 1 mains adapter · 4 x 3 m voltage cables with 4 mm banana connections (5 cables for CA 8336) · 4 crocodile clips (5 clips for CA 8336) · 1 safety datasheet · 1 set of 12-colour markers for the cables and inputs · 1 scratchproof protective screen film (mounted) · 1 CD-ROM containing the Power Analyser Transfer PC data recovery software Don't forget to order your current sensors too: see page 104 SPECIFICATIONS Number of channels Number of inputs IEC 61000-4-30 Voltage (TRMS AC+DC) Voltage ratio Current (TRMS AC+DC) MN C193 AmpFLEX® or MiniFlex PAC93 E3N J93 Current ratio Frequency Power values Energy values Harmonics THD Expert mode Transients Flicker Unbalance Min/Maxrecording of a selection of parameters at max. sampling rate Alarms Peak Vectorial representation Display Screenshots & curves Electrical safety Ingress protection Languages Communication interface Battery life Power supply Dimensions / weight CA 8333 3U / 4I 4V / 3I EN50160 reports 2 V to 1,000 V Up to 500 kV MN93: 500 mA to 200 Aac ; MN93A: 0.005 Aac to 100 Aac 1 A to 1,000 Aac 100 mA to 10,000 Aac 1 A to 1,300 Aac/dc 50 mA to 100 Aac/dc 50 A to 3,500 Aac / 50 A to 5,000 Adc Up to 60 kA 40 Hz to 69 Hz W (P), VA (S), var (Q1, N, D), PF, DPF, cos , tan Wh, varh (Q1h, Nh, Dh), VAh Yes Yes, orders 0 to 50, phase Yes 50 Pst Yes Yes From a few days to several weeks 4,000 of 10 different types Yes Automatic Colour ¼ VGA TFT screen, 320 x 240, diagonal 148 mm 12 IEC 61010 1 000 V CAT III / 600 V CAT IV IP53 / IK08 More than 27 USB Up to 10 hours Rechargeable 9.6 V NiMH battery or mains power supply 240 x 180 x 55 mm / 1.9 kg TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 389 POWER QUALITY & INSTALLATION MONITORING > THREE-PHASE NETWORK AND POWER ANALYSERS > CA 8336 CA 8336 REF.: P01160591 53 1000 V 600 V 4U CAT III CAT IV 4I IP IEC EN 61000-4-30 50160 Diagnostics & testing Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · TRMS AC+DC voltage and current, frequency · Measurements for power surveys · Measurements for sizing the anti-harmonic filters · Inrush mode (startup of the load) · Capture of all transients, alarms and waveforms ADDITIONAL INFO · Module for power supply by the phase (option) for unlimited recording SPECIFICATIONS Number of channels Number of inputs IEC 61000-4-30 Voltage (TRMS AC+DC) Voltage ratio Current (TRMS AC+DC) MN C193 AmpFLEX® or MiniFlex PAC93 E3N J93 Current ratio Frequency Power values Energy values Harmonics THD Expert mode Transients Flicker Inrush mode Unbalance Min/Maxrecording of a selection of parameters at max. sampling rate Alarms Peak Vectorial representation Display Screenshots & curves Electrical safety Ingress protection Languages Communication interface Battery life Power supply Dimensions / weight CA 8336 4U / 4I 5V / 4I EN50160 reports 2 V to 1 000 V Up to 500 kV MN93: 500 mA to 200 Aac ; MN93A: 0.005 Aac to 100 Aac 1 A to 1,000 Aac 100 mA to 10,000 Aac 1 A to 1,300 Aac/dc 50 mA to 100 Aac/dc 50 A to 3,500 Aac / 50 A to 5,000 Adc Up to 60 kA 40 Hz to 69 Hz W (P), VA (S), var (Q1, N, D), PF, DPF, cos , tan Wh, varh (Q1h, Nh, Dh), VAh Yes Yes, orders 0 to 50, phase Yes 210 Pst and Plt Yes > 10 minutes Yes Yes From 2 weeks to several years 10,000 of 40 different types Yes Automatic Colour ¼ VGA TFT screen, 320 x 240, diagonal 148 mm 50 IEC 61010 1 000 V CAT III / 600 V CAT IV IP53 / IK08 Plus de 27 USB Up to 10 hours Rechargeable 9.6 V NiMH battery or mains power supply 240 x 180 x 55 mm / 1.9 kg FUNCTIONS · Real-time display of the waveforms (5 voltage inputs and 4 current inputs) · RMS voltage and current measurements by the ½-period · Intuitive use · Automatic recognition of the different types of current sensors · Integration of all the DC components · Voltage and current ratios · Mixing of current sensors · Measurement, calculation and display of the harmonics up to the 50th order, along with their phase information · Calculation of the Total Harmonic Distortion (THD) · Capture of transients as short as one sample (1/256th of a period) · Display of phasor diagram · Power measurements: VA, W, VAD, total var and var per phase · Energy measurement: VAh, Wh, VADh, total varh and varh per phase · Calculation of the K factor FHL · Calculation of the Displacement Power Factor cos (DPF) and power factor PF · Capture of up to 210 transients · Calculation of Flicker PST & PLT · Calculation of the unbalance (current and voltage) · Electrical network supervision with setting of alarms · Backup and recording of screenshots (image and data) · Recording and export on PC · Real-time PC data recovery and communication software · EN 50160 report CONTENTS CA 8336 delivered with: · 1 bag No. 22 · 1 USB cable · 1 mains adapter · 5 x 3 m voltage cables with 4 mm banana connections · 5 crocodile clips · 1 safety datasheet · 1 set of 12-colour markers for the cables and inputs · 1 scratchproof screen protection film (mounted) · 1 CD-ROM containing the Power Analyser Transfer PC data recovery software Don't forget to order your current sensors too: see page 104 902 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com POWER QUALITY & INSTALLATION MONITORING > THREE-PHASE NETWORK AND POWER ANALYSERS > CA 8436 CA 8436 REF.: P01160595 1000 V 600 V 4U CAT III CAT IV 4I 67IP IEC EN 61000-4-30 50160 Diagnostics & testing Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Power supply via the phase · Measurements for power surveys · Measurements for sizing the anti-harmonic filters · Recording of all the parameters simultaneously · Capture of all the transients, alarms and waveforms FUNCTIONS · Real-time display of the waveforms (5 voltage inputs and 4 current inputs) · RMS voltage and current measurements per ½-period · Intuitive use · Automatic recognition of the different types of current sensors · Integration of all the DC components · Voltage and current ratios · Mixing of current sensors · Measurement, calculation and display of the harmonics up to the 50th order, along with their phase information · Calculation of the Total Harmonic Distortion (THD) · Capture of transients as short as one sample (1/256th of a period) · Display of phasor diagram · Power measurements: VA, W, VAD, total var and var per phase · Energy measurements: VAh, Wh, VADh, total varh and varh per phase · Calculation of K factor FHL · Calculation of the Displacement Power Factor cos (DPF) and the power factor PF · Capture of up to 210 transients · Calculation of Flicker PST & PLT · Calculation of unbalance (current and voltage) · Electrical network supervision with setting of alarms · Backup and recording of screenshots (image and data) · Recording and export on PC · Real-time PC data recovery and communication software · EN 50160 report CONTENTS CA 8436 delivered with: · 1 bag No. 22 · 1 waterproof power cord · 1 USB cable · 1 mains adapter IP65 · 5 x 3 m voltage cables with 4 mm banana connections with waterproof connector · 5 crocodile clips · 1 set of waterproof caps · 1 set of 12-colour markers for the cables and inputs · 1 scratchproof screen protection film (mounted) · 1 safety datasheet · 1 CD-ROM containing the Power Analyser Transfer PC data recovery software Don't forget to order your current sensors too: see page 104 ADDITIONAL INFO · Specific watertight AmpFlex® and MiniFlex current sensors are available SPECIFICATIONS CA 8436 Number of channels 4U / 4I Number of inputs 5V / 4I IEC 61000-4-30 - Voltage (TRMS AC+DC) 2 V to 1,000 V Voltage ratio Up to 500 kV Current (TRMS AC+DC) MN MN93: 500 mA to 200 Aac ; MN93A: 0.005 Aac to 100 Aac C193 AmpFLEX® or MiniFlex 1 A to 1,000 Aac 30 A to 6,500 Aac PAC93 1 A to 1,300 Aac/dc E3N 50 mA to 100 Aac/dc J93 50 A to 3,500 Aac / 50 A to 5,000 Adc Current ratio Up to 60 kA Frequency 40 Hz to 69 Hz Power values Energy values Harmonics W (P), VA (S), var (Q1, N, D), PF, DPF, cos , tan Wh, varh (Q1h, Nh, Dh), VAh Yes THD Yes, orders 0 to 50, phase Expert mode Yes Transients 210 Flicker Pst and Plt Inrush mode Yes > 10 minutes Unbalance Yes Min/Max recording Yes of a selection of parameters at max. sampling rate From 2 weeks to several years Alarms 10,000 of 40 different types Peak Yes Vectorial representation Automatic Display Colour ¼ VGA TFT screen, 320 x 240, diagonal 148 mm Screenshots & curves 12 Electrical safety IEC 61010 1 000 V CAT III / 600 V CAT IV Ingress protection IP67 Languages More than 27 Communication interface USB Battery life Up to 10 hours Power supply Rechargeable 9.6 V NiMH battery or mains power supply Dimensions / weight 270 x 250 x 180 mm / 3.7 kg TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 391 POWER QUALITY & INSTALLATION MONITORING > VOLTAGE QUALITY ANALYSER > CA 8345 CA 8345 REF.: P01160657 1000 V IP CAT IV 54 Diagnostics & testing Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology CEI 61000-4-30 WEB SERVER STRENGTHS · Full compliance with IEC 61000-4-30 in Class A · Extra-communicating instrument · Qualistar range of easy-to-use products ADDITIONAL INFO ·Also available in a version powered via the voltage channels up to 1,000 Vac and dc. CONTENTS CA 8345 delivered with: · Safety datasheet · Multilingual Quick Start Guide · USB cable + Charger for Europe · Verification certificate · Removable handle strap · Set of 5 banana leads and crocodile clips · 5 reeling boxes · USB A/B cable, length 1.80 m · Set of identification rings and inserts · Magnetic hook · SD memory card · PA40W-2 mains power pack and charger with mains power lead · Carrying bag Don't forget to order your current sensors too: see page 104 SPECIFICATIONS Inputs Voltage IEC 61000-4-30 (Ed 3) Screen Battery cartridge Real-time mode Sampling rate Power mode Energy mode Unbalance mode Harmonics mode Interharmonics mode Trend recording Recording of phase of harmonics Alarm mode (type / number) Carrier current detection mode Inrush capture Transients (number) Shockwaves EN50160 monitoring mode USB communication SD card Ethernet Wifi Webserver USB key port (Type A) Wide range of current sensors IEC 61010 safety Protection Temperature Environmental conditions Dimensions (H x W x D) Warranty CA 8345 Isolated voltage/current inputs Up to 1,000 Vac dc Class A (Full) 7" colour touch LCD: 800 x 480 (WVGA) Li-ion Yes 400 ksps for voltage and 200 ksps for current Yes Yes Composite DC to 63rd order Orders 0 to 62 > 900 parameters Yes 52 / 20,000 Yes 100 No maximum (SD card) Up to 12 kV over a duration of 500 ns @ 2 Msps With PAT3 software Yes Externally accessible Yes Yes Yes Yes See page 140 CAT IV 1000V IP54 [+0 °C; +40 °C] IEC 61557-12 & IEC 62586 200 x 285 x 55 mm / 1.9 kg 3 years ACCESSORIES / REPLACEMENT PARTS 1,000 V STD PA32ER power supply PA40W-2 mains adapter C8 adapter Bag SD card Magnetized hook Handle strap External battery charging station Li-ion battery pack P01103076 P01102155 P01103077 P01298083 P01103078 P01103079 HX0122 P01102130 P01296047 922 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com POWER QUALITY & INSTALLATION MONITORING > SOLAR POWER ANALYSER > FTV500 FTV500 REF.: P01129600 600 V CAT III IP 54 WEB SERVER Diagnostics & testing Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology SPECIFICATIONS FTV500 Number of channels 6 (3 DC voltage and current channels, 3 AC voltage and current channels) Connection 4 mm banana plugs Measurement ranges Vd c 3 to 999.9 Vdc Va c @ 50/60 Hz 3 to 700.0 Vac Id c 1 to 1,400 Adc Ia c @ 50/60 Hz 1 to 3,000 Aac Environment Irradiation 50 to 2,000 W/m² Contact temperature -20 °C to + 150°C Ambient temperature -20 °C to + 150°C I-V curves DC power 5 to 9 999 WDC Continuity Measurement range 0.01 to 99 , > 200mA (IEC 61557-4) Insulation Test voltage 250-500-1,000 V Measurement range (without voltage) 0.25 to 1 M Measurement range (with voltage) 0.25 to 1 M DC-AC performance Measurements performed simultaneously Irradiation, temperature (ambient/module), AC/DC power values (measured and theoretical available), Power Factor, AC/DC, voltage, AC/DC current, PRp performance ratio and AC/DC performance, V-I vectorial diagram Recording Measurements performed simultaneously Irradiation, temperature (ambient/module), AC/DC power values (measured and theoretical available), Power Factor, AC/DC, voltage, AC/DC current, PRp performance ratio and AC/DC performance General Display 5'' TFT touch screen, 16 million colours, 800x480 Wifi Real-time Wi-Fi transmission, mode / real-time synchronization and recording of data if signal lost Interface Instrument VNC remote control Remote unit Wifi transmission Data storage I-V curves Programmable internal database: sites / installations / companies / modules / measurements, with tree-structure. Memory: more than 10,000 blocks for all the measurements. Logger Logger: 600,000 measurements for data logging Power supply / Battery life Instrument Li-ion rechargeable batteries and 100-240V mains power supply @ 50-60Hz / Battery life 15 hours Remote unit Li-ion rechargeable batteries with USB charging cable / Battery life 15 hours Mechanical specifications Dimensions 340 x 300 x 200mm Weight 6 kg Electrical safety IEC 61010, 1000 V CAT II, 600 V CAT IV Protection (instrument & remote) IP54 (IEC 60529) Warranty 2 years STRENGTHS · Touch screen · 5 instruments in 1: converter efficiency, I-V curves, continuity test, insulation test, logger · Live insulation tests · EN62446, EN60891, EN60904, IEC 82-25, EN61557, IEC 64-8 and EN61010 standards ADDITIONAL INFO · Installation and maintenance tests on solar power installations · Verification during installation of solar power installations CONTENTS F TV500 delivered with: · Carrying bag · Certificate of conformity · 12 red/black banana leads 2 m long · 12 crocodile clips · 3 x MiniFlex MA500 AC sensors · 3 x PAC500 DC sensors · I-V cable for DC connection · USB cable · FTV500 mains adapter · FTV500 remote unit · User's manual (5 languages) on USB key · Software on USB key · Inclinometer AR ECPCLEASCSEOMRIEENST/ PARTS MiniFlex MA500 PAC500 DC clamp FTV500 remote unit Inclinometer P01120080 P01120600 P01102184 P01102115 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 393 POWER QUALITY & INSTALLATION MONITORING > ELECTRICAL MEASUREMENT LOGGERS > SELECTION GUIDE CHOOSE YOUR ELECTRICAL MEASUREMENT LOGGER PEL51 PEL52 PEL102 PEL103 PEL104 page 95 page 95 page 96 page 96 page 96 PEL106 page 97 Display Without With No. of inputs 1U/1I 2U/2I 3U/3I 3U/3I 3U/3I 4U/4I Current AC DC Voltage AC 690 V DC 690 V 1,000 V 1,000 V 1,000 V 1,000 V 1,000 V 1,000 V 1,000 V 1,000 V Process 4-20 mA 0-10 V Power values Data storage PNQ1DS PNQ1DS PQS PQS PNQ1DS PNQ1DS Internal SD card Communication USB Wifi Bluetooth RJ45 Webserver GPRS IRD server Power supply Mains via the phase Mains via the phase Mains via the phase (opt) Mains via the phase (opt) Mains via the phase (opt) Mains via the phase Protection IP54 IP54 IP54 IP54 IP54 IP67 Safety IEC 6010 CAT III 600V CAT III 600V CAT III 1000V CAT IV 600 V CAT III 1000V CAT IV 600 V CAT III 1000V CAT IV 600 V CAT IV 1000V L411 page 98 L412 L461 DL913 DL914 L452 page 99 page 100 page 101 page 101 page 101 1I 2I 1U 3I 4I 2I/U 1,000 V 1,500 V 4-20 mA 0-10 V Batteries Batteries Batteries Batteries Batteries Batteries IP54 IP54 IP54 IP65 IP65 IP54 CAT III 1000V CAT III 1000V CAT III 1000V CAT III 1000V CAT II 300V 942 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com POWER QUALITY & INSTALLATION MONITORING > ELECTRICAL MEASUREMENT LOGGERS > PEL51 - PEL52 PEL51 - PEL52 REF.: P01157166 REF.: P01157167 600 V CAT III Diagnostics & testing Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology TRMS WEB SERVER STRENGTHS · Measurement up to 690 V · Power supply via the phase · Alarm function ADDITIONAL INFO · Monitoring of voltage variations, · Electrical troubleshooting, etc. CONTENTS · PEL51 or PEL52 · Verification sheet · Safety datasheet · 2 banana leads 1.5 m long for PEL51, 3 banana leads 1.5 m long for PEL52 · 2 crocodile clips for PEL51, 3 crocodile clips for PEL52 · C8 banana adapter · Quick Start Guide in 15 languages · User's manual available for downloading · PEL Transfer software available for downloading · 1 mains power cable SPECIFICATIONS PEL51 PEL52 Display Backlit LCD (blue) with double display Real-time measurements Type of installation Single-phase Single-phase, split-phase, two-phase Number of channels 1V / 1I 2V / 2I Type of inputs 2 x 4mm terminals 3 x 4mm terminals + 1 Qualistar-type current input + 2 Qualistar-type current inputs Measurements Network frequencies DC, 50 Hz, 60 Hz Voltage (measurement range) 10 Vac to 690 Vac Accuracy Va c @ 50/60 Hz +/- (0.2% + 0.2V) MN93 MN93A Current C193 AmpFlex® A193 & MiniFlex MA194 Calculated measurements Ratios P, Q1, N, S, D power values Energy Phase Harmonics Additional functions Min / Max Mounting Programmable storage interval Recording modes Data storage Recording duration Communication Power supply Safety Mechanical specifications Dimensions Weight Casing Warranty 500 mA to 200 Aac 5 mA to 100 Aac 1 A to 1,000 Aac 500 mA to 2,400 Aac Up to 25,000 A 10 W to 10 MW / 10 var to 10 Mvar / 10 VA to 10 MVA Up to 4 EWh / 4 EVAh / 4 Evarh (E = 1018) cos , tan , PF THD Yes Magnet 1 s to1 hour (Min/Avg/Max) "Stop when full" SD card, 8 GB (SD-HC card up to 32 GB) Depends on the SD card, programmable using the software USB, Wifi & Bluetooth Via the phase, 90 V - 690 V @ 50-60 Hz IEC 61010 1000 V CAT III 180 x 88 x 37 mm without sensor 400 g IP54 (IEC 60529) 2 years ACCESSORIES / REPLACEMENT PARTS Carrying bag See all the accessories on page 105 P01298071 Don't forget to order your current sensors too: see page 104 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 395 POWER QUALITY & INSTALLATION MONITORING > SIMULTANEOUS POWER AND ENERGY LOGGERS > PEL102 - PEL103 - PEL104 PEL102 - PEL103 - PEL104 REF.: P01157152 REF.: P01157153 REF.: P01157154 IP 67 Diagnostics & testing Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Suitable for all types of cabinets and all Low Voltage electrical installations · Implementation without powering down the electrical network · Recording duration of several months or years · Breakdown of energy losses · Characterization of electric motors CONTENTS · A PEL102 or PEL103 delivered with: 1 carrying bag, 4 measurement leads (straight banana/straight banana 3 m long - black), 4 crocodile clips (black), 1 set of rings for the extremities of the leads and current sensors), 1 mains power cable, 1 x 8 GB SD card, 1 USB cable, 1 SD-USB adapter, PC software (PEL Transfer), 1 user's manual, 1 safety datasheet, 1 Quick Start Guide. · A PEL104 with: 1 carrying bag, 4 voltage leads, 4 crocodile clips, PC software (PEL Transfer), 1 set of rings and inserts, 1 x 600V mains adapter, 1 SD card, 1 SD-USB adapter, 1 USB cable, 1 user's manual in multiple languages, 1 Quick Start Guide. Manual available for download from our website. SPECIFICATIONS Display Types of installations Number of channels Measurements Network frequencies Voltage (measurement ranges / best accuracy) Current (depending on sensors) (measurement ranges/ best accuracy) Calculated measurements Ratio Power Energy Phase Harmonics Additional functions Phase sequence Min / Max Mounting Logging Sampling rate / Acquisition interval / Aggregation Data storage Communication Power supply Safety Mechanical specifications Dimensions Weight Casing PEL102 PEL103 PEL104 None With quadruple digital display Single-phase, split-phase, three-phase with or without neutral and many other specific configurations 3 Voltage inputs, 3 Current inputs (calculated neutral current) DC, 50 Hz, 60 Hz and 400 Hz 10.00 -1,000 Vac/dc 5 mAac to 10 kAac / 50 mAdc to 1.4 kAdc Up to 650,000 V / up to 25,000 A 10 W to 10 GW / 10 var to 10 Gvar / 10 VA to 10 GVA Up to 4 EWh / 4 EVAh / 4 Evarh (E = 1018) cos , tan , PF THD Yes Yes Magnet 1 meas./s - 1 min to 60 min 5 meas./s 1 min to 60 min SD card, 8 GB (SD-HC card up to 32 GB) Ethernet, Bluetooth and USB Ethernet, Bluetooth, USB, Wifi and GPRS 110 V - 250 V (+10 %, -15 %) @ 50-60 Hz & 400 Hz IEC 61010 600 V CAT IV and 1000 V CAT III 256 x 125 x 37 mm without sensor 900 g 950 g 900 g IP54 ACCESSORIES / REPLACEMENT PARTS C193 clamp MN93 clamp MN93A clamp E3N clamp E3N adapter E27 clamp PAC93 clamp J93 clamp AmpFlex® A193 clamp -450 mm AmpFlex® A193 clamp -800 mm MiniFlex MA194 clamp -250 mm MiniFlex MA194 clamp -350 mm MiniFlex MA194 clamp -1000 mm Mains power cable PEL100 mains adapter Leads/clamps kit (x4) Set of rings/inserts 5 A adapter DataVIEW® software Bag no. 23 P01120323B P01120425B P01120434B P01120043A P01102081 P01120027 P01120079B P01120110 P01120556B P01120531B P01120593 P01120592 P01120594 P01295174 P01102174 P01295476 P01102080 P01101959 P01102095 P01298078 962 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com POWER QUALITY & INSTALLATION MONITORING > ALL-TERRAIN POWER AND ENERGY LOGGERS > PEL106 PEL106 REF.: P01157165 IP 67 Diagnostics & testing Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · All-terrain IP67 casing resistant to shocks, UV light and high temperature · Communication: Wifi, UMTS/GPRS, LAN (Ethernet network), Bluetooth and USB · Self-powered via its voltage inputs up to- 1,000 V · Continuous recording with a 200 ms acquisition interval · Measurements in compliance with the IEEE 1459 standard · 4 voltage inputs & 4 current inputs · Ideal for implementation on an electricity pole ADDITIONAL INFO ·The PEL106 is equipped with a quadruple digital display which is ideal for real-time power quality monitoring. CONTENTS · A PEL106 with: · 1 bag for the accessories · 5 x IP67 leads · 5 lockable crocodile clips · 1 set of inserts and rings · PC software (PEL Transfer) · 1 SD card · 1 SD-USB adapter · 1 USB cable · 1 user's manual in multiple languages · 1 Quick Start Guide SPECIFICATIONS Display Types of installations Number of channels Measurements Network frequencies Voltage (measurement ranges / best accuracy) Current (depending on sensors) (measurement ranges/ best accuracy) Calculated measurements Ratio Power Energy Phase Harmonics Additional functions Phase sequence Min / Max Mounting Analogue measurements Logging Sampling rate / Acquisition interval / Aggregation Data storage Communication Power supply Safety Mechanical specifications Dimensions Weight Casing PEL106 With quadruple digital display Single-phase, split-phase, three-phase with or without neutral and many other specific configurations 4 voltage inputs, 4 current inputs DC, 50 Hz, 60 Hz and 400 Hz 10.00 -1,000 Vac/dc 5 mAac to 10 kAac / 50 mAdc to 1.4 kAdc Up to 650,000 V / up to 25,000 A 10 W to 10 GW / 10 var to 10 Gvar / 10 VA to 10 GVA Up to 4 EWh / 4 EVAh / 4 Evarh (E = 1018) cos , tan , PF THD Yes Yes Hook (Opt.) Up to 8 channels 5 meas./s - 1 min to 60 min SD card, 8 GB (SD-HC card up to 32 GB) Ethernet, Bluetooth, USB, Wifi and GPRS Power supply via the phase 1,000 Vac/dc IEC 61010 1000 V CAT IV 245 x 270 180 mm <3,400 g IP67 ACCESSORIES / REPLACEMENT PARTS AmpFlex® A196 clamp -610 mm MiniFlex MA196 clamp -350 mm Leads kit (x 5) BB196 See all the accessories on page 105 P01120552 P01120568 P01295479 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 397 POWER QUALITY & INSTALLATION MONITORING > TRMS CURRENT LOGGERS > L411 L411 REF.: P01157180 1000 V CAT III TRMS WEB SERVER Diagnostics & testing Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Stand-alone with captive sensor · Alarm function · Simplified use: magnetized, single connection without cutting the power supply; once parameterized, the measurements are performed independently and extraction to a PC is automatic. SPECIFICATIONS Number of channels Connection Current range Accuracy (50/60 Hz) Programmable storage interval Recording modes Recording duration Display Data storage Wired communication Wireless communication Power supply Battery life Mechanical specifications Dimensions / weight Sensor size Electrical safety Casing Protection Warranty L411 1 MiniFlex (captive) 500 mAac to 3,000 Aac; @ 50/60 Hz 0.1 to 100 A: ± (1 % R + 2 D) 90 to 400 A: ±(1 % R + 4 D) 1 s to 1 hour (Min/Avg/Max) "Stop when full" Depends on SD card, programmable using the software Backlit LCD (blue) Real-time measurements SD / SD-HC / SD-XC Optically-isolated USB 2.0 Wifi (direct and router mode) 3 x AA (or rechargeable) batteries; or via USB (Opt.) 14 days' recording 150 x 72 x 32 mm / 260g with batteries Ø 70 / 250 mm (14''), with 1.20 m connection cable IEC 61010, 1000 V CAT III UL-V1 IP54 (IEC 60529) 2 years ACCESSORIES / REPLACEMENT PARTS DataView Shockproof sheath + Multifix accessory Bag S03 P01102095 P01654252 P01298076 ADDITIONAL INFO · Machine load monitoring · Electrical troubleshooting, etc. CONTENTS · L411 · Safety datasheet · Multilingual Quick Start Guide downloadable from our website · USB cable · USB mains adapter · SD card 982 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com POWER QUALITY & INSTALLATION MONITORING > TRMS CURRENT LOGGERS > L412 L412 REF.: P01157181 TRMS WEB SERVER Diagnostics & testing Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Split-phase measurement · Stand-alone with secure connections · Alarm function · Wide range of current sensors ADDITIONAL INFO · Machine load monitoring · Electrical troubleshooting, etc. SPECIFICATIONS Number of channels Connection Current range @ 50/60 Hz A194/MA194 C193 MN93A MN93 Accuracy (50/60 Hz) Programmable storage interval Recording modes Recording duration Display Data storage Wired communication Wireless communication Power supply Battery life Mechanical specifications Dimensions / weight Sensor size Casing Protection Warranty L412 2 Qualistar connection technology 400 mAac to 2,000 Aac ; @ 50/60 Hz 100 mAac to 1,200 Aac 1 Aac to 1,000 Aac 5 mAac to 100 Aac 100 mA to 200 Aac Depends on sensor 1 s to 1 hour (Min/Avg/Max) "Stop when full" Depends on SD card, programmable using the software Backlit LCD (blue) Real-time measurements SD / SD-HC / SD-XC Optically-isolated USB 2.0 Wifi (direct and router mode) 3 x AA (or rechargeable) batteries; or USB (Opt.) 14 days' recording 150 x 72 x 32 mm / 260 g with batteries Ø 350 mm (14''), with 1.20 m connection cable UL-V1 IP54 (IEC 60529) 2 years ACCESSORIES / REPLACEMENT PARTS MA194-250 flexible current sensor MN93A current sensor DataView software Shockproof sheath + Multifix accessory Bag S03 P01120593 P01120434B P01102095 P01654252 P01298076 CONTENTS · L412 · Safety datasheet · Multilingual Quick Start Guide downloadable from our website · USB cable · USB mains adapter · SD card TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 399 POWER QUALITY & INSTALLATION MONITORING > TRMS VOLTAGE LOGGER > L461 L461 REF.: P01157182 1000 V CAT III TRMS WEB SERVER Diagnostics & testing Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology SPECIFICATIONS Number of channels Connection Voltage range Va c @ 50/60 Hz Vd c Accuracy Va c @ 50/60 Hz Vd c Programmable storage interval Recording modes Recording duration Display Data storage Wired communication Wireless communication Power supply Battery life Mechanical specifications Dimensions Weight (with batteries) Electrical safety Casing Protection Warranty L461 1 (2 terminals) 4 mm banana plugs 100 mVac to 999.9 Vac 100 mVdc to 1,499 Vdc 0.1 to 999.9 V: ± (1 % R + 5 D) 900 to 1,200 V: ±(1 % R + 1 D) 0.1 to 999.9 V: ± (1 % R + 5 D) 900 to 1,500 V: ±(1 % R + 1 D) 1 s to 1 hour (Min/Avg/Max) "Stop when full" Depends on the SD card, programmable using the software Backlit LCD (blue) Real-time measurements SD Optically-isolated USB 2.0 Wifi (direct and router mode) 3 x AA (or rechargeable) batteries; or USB (Opt.) 14 days' recording 235 x 102 x 41 mm 260 g IEC 61010, 1000 Vac CAT III IEC 61010, 1500 Vdc CAT III UL-V1 IP54 (IEC 60529) 2 years STRENGTHS · Measurement up to 1,000 Vac / 1,500 Vdc · Power supply via the phase · Alarm function · Power supply by current sensor ADDITIONAL INFO · Machine load monitoring · Electrical troubleshooting, etc. CONTENTS · L461 · Safety datasheet · Multilingual Quick Start Guide · C8 adapter · 2 x 4 mm silicone banana leads for voltage · 2 crocodile clips · USB cable · SD card ACCESSORIES / REPLACEMENT PARTS Carrying bag Shockproof sheath + Multifix accessory P01298071 P01654252 1002 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com POWER QUALITY & INSTALLATION MONITORING > TRMS CURRENT LOGGER > DL913 - DL914 | L452 DL913 - DL914 REF.: P01157170 REF.: P01157171 Diagnostics & testing Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology 1000 V 600 V CAT III CAT IV TRMS IP 65 STRENGTHS · IP65 waterproof measuring instrument · IRD server connection SPECIFICATIONS Number of channels Connection Current range Accuracy (50/60 Hz) Programmable storage interval Recording modes Recording duration Display Data storage Wired communication Wireless communication Power supply Battery life Mechanical specifications Dimensions / weight Sensor size Electrical safety Casing Protection DL913 DL914 3 4 24'' MiniFlex (captive) 100 mAac to 10,000 Aac @ 50/60 Hz ± (1 % of reading + 4 D) 1 s to 1 hour (Min/Avg/Max) "Stop when full" Depends on SD card, programmable using the software Backlit LCD (blue) Real-time measurements SD Optically-isolated USB 2.0 Wifi (direct and router mode) Rechargeable NiMH batteries 14 days' recording 150 x 72 x 32 mm / 260g with batteries Ø 100 / 350 mm (14'') length, with 1.20 m connection cable IEC 61010, 1000 V CAT III UL-V1 IP65 (IEC 60529) ADDITIONAL INFO · Machine load monitoring, · Electrical troubleshooting , etc. CONTENTS · DL913 or DL914 · Safety datasheet · Multilingual Quick Start Guide downloadable from our website · USB cable + European-format charger · Verification certificate. ACCESSORIES / REPLACEMENT PARTS DataView Bag N°23 (option) P01102095 P01298078 L452 REF.: P01157201 Diagnostics & testing Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Process data logger with display · 2 measurement channels · Events counter · Dry contact closure · Detection of logic levels SPECIFICATIONS L452 Measurement range Resolution Accuracy (% reading) Sampling rate DC current 4 to 20 mA ± 100 mV 0.01 mA 0.05 mA (0.25 %) 5 samples/s ± 0.1 mV ± 0.1 mV (0.5 %) DC voltage ± 1 V ± 1 mV ± 1 mV (0.5 %) ± 5 samples/s Pulse Digital Pulse voltage Battery life in operation Power supply Recording modes Control Recording duration Examples Acquisition interval Communication ± 10 V ± 10 mV ± 10 mV (0.5 %) - 1 ms - - 1 s (max. - 1 ms recording - duration: 1 month) 3.3 V (with 1 000 000 pull-up) 200 ms acquisition with display On: 18 days 200 ms acquisition with display Off: 36 days 1 min acquisition with display Off: 270 days 110 to 240 V (50/60 Hz) External: via USB connector Internal: 2.4 V rechargeable NiMH batteries (2 x 1.2 V) Start/Stop (stops when memory full or when campaign end date reached) Local mode (multidirectional keypad on front panel) Remote mode (control via PC) 10 minutes to 1 year, configurable 2 channels @ 200 ms: 19 days 2 channels @ 1 min: > 1 year (theoretical) 200 ms to 1 hour Bluetooth 2.1, class 1, USB 2.0 Dimensions Weight Display Measurement terminal strip 32.4 x 65.5 x 125 mm (137.5 mm with screw connector) 206 g LCD 128 x 64 pixels 6 screw terminals Operating temperature 0 to 50 °C Protection Electrical protection IP42 (terminal strip IP20) IEC 61010-1 Ed. 3 and IEC 61010-2-030 Ed. 1 ADDITIONAL INFO · To simplify use, the rear panel of the L452 is magnetized. You can also use the Multifix system or a wall-mount. CONTENTS · L452 logger · 1 adapter and 1 USB power cable · 1 CD-ROM containing the Datalogger Transfer software ACCESSORIES / REPLACEMENT PARTS USB power cable Screw connector kit (x 5) See all the accessories on page 105 P01102148 P01295489 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3101 POWER QUALITY & INSTALLATION MONITORING > DATA PROCESSING SOFTWARE > DATAVIEW® DATAVIEW® REF.: P01102095 PAT PAT 2 PAT 3 PEL DATA TRANSFER LOGGER Diagnostics & testing Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology PEL TRANSFER FOR PEL100 With the following complementary functions: · Breakdown of the energy values to detect any losses · Display of trend curves · Current sensor inversion if set up incorrectly · Configuration for GPRS communication POWER ANALYZER TRANSFER 3 FOR CA 8345 With the following complementary functions: · Display of events (transients, Inrush, Surge, etc.) · Configuration of monitoring mode (EN50160) · Configuration for communication with IRD server POWER ANALYZER TRANSFER 2 FOR CA 8331 / CA 8336 AND CA 8333 The PAT 2 module of DataView® offers complementary functions: · Configuration of alarms · Configuration of transients · Configuration of trend curves · Real-time display · Data recovery, backup and export · Launch of measurement campaign after automatic configuration of the associated instrument. FUNCTIONS · Configuration of all the functions of instruments connected to a PC or via Bluetooth® · Recovery of recorded measurement data · Backup of measurement files · Opening of saved files · Processing and report creation (EN50160) · Export into an Excel spreadsheet · Export in .pdf format · Database management REQUIRED CONFIGURATION · Windows Vista & Windows 7/8/10 (32/64 bit) · 1 GB RAM for Windows Vista & Windows 7/8 (32 bit) · 2 GB RAM for Windows Vista & Windows 7/8 (64 bit) · 80 MB available hard-disk space (200 MB recommended) ADDITIONAL INFO · The Dataview® software: ·Automatically recognizes the instrument connected when it is hooked up to the PC and opens the corresponding menu. Users then have direct access to its configuration and the data stored on it ·Equipped with a large number of predefined report templates for quick generation in accordance with the applicable standards. Users can also create their own templates to meet their needs and directly add their own comments DataView® modules Related products PAT F407 F607 CA 8220 PAT 2 CA 8331 CA 8333 CA 8336 CA 8436 PAT 3 CA 8345 PEL TRANSFER PEL102 PEL103 PEL104 PEL106 PEL51 PEL52 DATALOGGER DL913 DL914 L411 L412 L461 L452 102 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com POWER QUALITY & INSTALLATION MONITORING > DATA PROCESSING SOFTWARE > DATAVIEW® PAT MODULE Display of data stored by an F407 clamp PAT 2 MODULE Configuration of EN 50160 parameters PEL TRANSFER MODULE Remote display of a vectorial representation DATA LOGGER MODULE Recording of 0 -10 V - 2 channels Measurement campaign reports TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3103 POWER QUALITY & INSTALLATION MONITORING > ACCESSORIES / REPLACEMENT PARTS POWER AND ENERGY QUALITY ANALYSERS AND LOGGERS CA 8220, CA 8331, CA 8333, CA 8336, CA 8436, PEL102, PEL103, PEL106 and PEL51, PEL52, L412 Check the compatibility of the measurement ranges CURRENT SENSORS Model MN93 Measurement range 500 mA to 200 Aac Clamping diam. / Length Ø 20 mm IEC 61010 600 V CAT III / 300 V CAT IV Reference P01120425B MN 93A MA194-250 MA194-350 MA194-1000 MA196-350 PAC93 5 mA to 100 Aac 100 mA to 10 kAac 1 A to 1,000 Aac / 1 A to 1,300 Adc Ø 20 mm Ø 70/250 mm Ø 100/350 mm Ø 300/1.000 mm Ø 100 mm / 350 mm 1 x Ø 39 mm or 2 x Ø 25 mm J93 50 A to 3,500 Aac / 50 A to 5,000 Adc Ø 72 mm A193-450 A196A-610 A193-800 100 mA to 10 kAac 100 mA to 10 kAac Ø 140 mm / 450 mm Ø 190mm / 610 mm Ø 250 mm / 800 mm 600 V CAT III / 300 V CAT IV 1000 V CAT III / 600 V CAT IV 600 V CAT III / 300 V CAT IV 600 V CAT III / 300 V CAT IV 1000V CAT III / 600 V CAT IV 1000V CAT IV 1000 V CAT III / 600 V CAT IV P01120434B P01120593 P01120592 P01120594 P01120568 P01120079B P01120110 P01120526B P01120554 P01120531B C193 E3N / E27 1 A to 1,000 Aac 50 mA to 10 Aac/dc 100 mA to 100 Aac/dc Ø 52 mm Ø 11,8 mm 600 V CAT IV 600 V CAT III / 300 V CAT IV Description Kit of 5 banana leads + 5 crocodile clips + 1 set of coloured rings P01120323B P01120027 Reference P01295483 Kit of 4 banana leads + 4 crocodile clips + 1 set of coloured rings P01295476 1 set of coloured inserts and rings 5 A adapter unit Reeling box Magnetized MultiFix cable winder USB-A USB-B cable P01102080 P01101959 P01102149 P01295293 Carrying bag no. 22 P01298056 OTHER ACCESSORIES DataView® software ESSAILEC unit P01102095 P01102131 1042 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com POWER QUALITY & INSTALLATION MONITORING > ACCESSORIES / REPLACEMENT PARTS ACCESSORIES / REPLACEMENT PARTS SORTIE VOLTAGE POWER AND ENERGY QUALITY ANALYSER CA 8220 · CA 1711 tachometer probe........................... P01102082 · 2-wire Pt100 adapter.................................... HX0091 · E27 clamp adapter........................................ P01102081 · E27 clamp.................................................... P01120027 · 230 V adapter with USB-B cable for E27....... P01651023 · Bag no. 5...................................................... P01298049 · Crocodile clips (1 red/1 black)....................... P01102057Z · Banana/banana leads (1 red/1 black)............ P01295288Z · Test probes (1 red/1 black)........................... P01295454Z · Pack of 6 NiMH rechargeable batteries.......... P01296037 · CA 82X0 EUR mains power supply................ P01160640 · Optical/USB cable........................................ HX0056Z · Current measurement lead............................ P03295509 · PAC93 mains adapter................................... P01101967 · DataView® software...................................... P01102095 · Set of 2 magnetized test probes (1 red / 1 black)...... P01103058Z · RS232 / USB Adapter................................... HX0055 THREE-PHASE POWER AND ENERGY QUALITY ANALYSER CA 8331 / CA 8333 / CA 8336 / CA 8436 · Belt bag no. 21............................................. P01298055 · Bag no. 22.................................................... P01298067 · Screen protection film................................... P01102059 · In-vehicle charger......................................... HX0061 · E3N adapter................................................. P01102081 · E3N mains power pack.................................. P01120047 · Battery pack................................................. P01296024 · PA30W mains power pack (CA 8331-33-35-36)...... P01102057 · PA31ER mains adapter.................................. P01102150 · PAC93 mains adapter................................... P01101967 · DataView® software...................................... P01102095 · ESSAILEC unit.............................................. P01102131 · Reeling Box................................................... P01102149 · Set of colour-coded inserts/rigs.................... P01102080 · IP 67 mains power cable (CA 8436).............. P01295477 · Set of caps (CA 8436).................................. P01102117 · Set of 5 x 3 m IP67 banana cables................ P01295479 · Banana mains power cable (CA 8436).......... P01295496 · USB-A / USB-B cable.................................... P01295293 · 5 A box......................................................... P01101959 · Set of 5 lockable crocodile clips.................... P01102099 · Kit of 5 banana leads, 5 crocodile clips and 1 set of coloured rings............................ P01295483 · Kit de 4 banana leads, 4 crocodile clips and 1 set of coloured rings............................ P01295476 CA 8345 · PA32ER 1,000 V mains power pack.............. P01103076 · PA40W-2 Li-Ion mains power pack............... P01102155 · C8 adapter................................................... P01103077 · Q2 bag......................................................... P01298083 · SD card........................................................ P01103078 · Magnetized hook........................................... P01103079 · E3N adapter................................................. P01102081 · E3N mains power pack.................................. P01120047 · PAC93 mains adapter................................... P01101967 · DataView® software...................................... P01102095 · ESSAILEC unit.............................................. P01102131 · Reeling Box................................................... P01102149 · Set of rings/inserts....................................... P01102080 · USB-A / USB-B cable.................................... P01295293 · 5 A box......................................................... P01101959 · Kit of 5 banana leads, 5 crocodile clips and 1 set of coloured rings............................ P01295483 POWER AND HARMONICS CLAMP MULTIMETER F407, F607 · Set of red/black banana/banana leads.......... P01295451Z · Set of red/black crocodile clips...................... P01295457Z · Magnetized MultiFix kit................................. P01102100Z · Bluetooth kit................................................. P01637301 · Bag no. S03................................................. P01298076 · DataView® software...................................... P01102095 POWER AND ENERGY LOGGER PEL51 and PEL52 · Bag no. S03................................................. P01298076 · Standard PVC cables with straight male 4 mm plugs...................... P01295288Z · 32 A crocodile clips....................................... P01102052Z · DataView® software...................................... P01102095 PEL102 and PEL103 and PEL104 · Bag no. 23.................................................... P01298078 · E3N adapter................................................. P01102081 · Mains power cable........................................ P01295174 · Mains adapter (self-powering)....................... P01102174 · PAC93 mains adapter................................... P01101967 · DataView® software...................................... P01102095 · Kit de 4 banana leads, 4 crocodile clips and 1 set of coloured rings............................ P01295476 PEL106 · Set of protective rubber plugs (5 small + 4 large)........................................ P01102147 · Pole-mounting kit......................................... P01102146 · Lockable crocodile clips kit (x5)..................... P01102099 · E3N adapter................................................. P01102081 · Set of IP 67 banana leads 3 m long (x5) BB196.......................................................... P01295479 · DataView® software...................................... P01102095 · Bag no. S21.................................................. P01298066 · PA30W mains power pack............................ P01102057 CURRENT LOGGERS L411 and L412 · DataView® software...................................... P01102095 · USB power cable........................................ P01102148 · Bag no. S03................................................. P01298076 DL913 and DL914 · DataView® software...................................... P01102095 · Bag no.20..................................................... P01298078 VOLTAGE LOGGERS L461 · 4 mm banana leads...................................... P01295288Z · 32 A crocodile clips....................................... P01102052Z · Bag no. S03................................................. P01298076 · Type A-to-mini B USB cable 2 m long............ Please contact us · Banana plug / female BNC adapter................ P01101846 · DataView® software...................................... P01102095 · USB power cable........................................ P01102148 PROCESS DATA LOGGER L452 · DataView® software...................................... P01102095 · USB power cable........................................ P01102148 · Wall mount................................................... P01651024 · MultiFix mounting adapter............................. P01102100Z · Screw connector kit (x 5).............................. P01295489 SOLAR POWER ANALYSER FTV500 · FTV500 remote unit...................................... P01102184 · Inclinometer.................................................. P01102115 · Flexible test probes....................................... P01102189 · FTV 500 battery........................................... P01296052 · FTV 500 mains adapter................................ P01295505 · Set of mc4 leads.......................................... P01295504 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3105 PHYSICAL & ENVIRONMENTAL MEASUREMENTS > INFO AND ADVICE > TEMPERATURE MEASUREMENT INFO AND ADVICE CALIBRATORS THERMAL CAMERAS THERMOMETERS 106 PH-METER 132 108 CONDUCTIVITY METER 133 111 OTHER PHYSICAL & ENVIRONMENTAL 116 MEASURING INSTRUMENTS 123 ACCESSORIES 135 TEMPERATURE MEASUREMENT Thermometers have always been essential instruments used by all industrial companies for: · Ambient temperature measurement. · Temperature monitoring in cold rooms and climatic chambers. · Temperature measurement on walls/partitions · Testing for hot spots in an electrical cabinet. · Checking of foodstuff freshness by inserting a probe in the heart of the product Chauvin Arnoux offers rugged, accurate, easy-to-use electronic thermometers: · Thermocouple thermometers. · Resistive probe thermometers. · No-contact thermometers. · Thermal cameras. THERMOCOUPLES The operating principle of thermocouples is based on the electromotive force created naturally between two conductor wires of different materials joined at the end (SEEBECK effect). This electromotive force depends on the temperature to which one of the two junctions is exposed. This temperature is measured as a voltage of a few millivolts. A thermocouple is therefore composed of two junctions (or welds) linking two different metals or alloys. One of the junctions, positioned at the point of measurement, is called the hot junction, while the other is called the cold junction and its known temperature serves as the reference. For two given materials or alloys, there is a relation between the electromotive force and the reference and measurement temperatures. This relation is usually expressed by a characteristic curve of sensitivity in mV/°C. RESISTIVE PROBES Some pure metals have a coefficient of resistivity which varies as a function of temperature in a reproducible way. The metals generally used are platinum and copper. Currently, the widest-used type is platinum, with a resistance of 100 at 0 °C. OPTICAL OR NO-CONTACT MEASUREMENTS All bodies emit electromagnetic radiation whose spectrum has an energy distribution which is a function of temperature. This measurement system offers quick temperature testing on parts which are current-carrying, moving or difficult to access. It can also be used for measurements of very high temperatures or on poor heat conductors such as ceramics or synthetic materials. CHOOSING THE RIGHT TEMPERATURE MEASUREMENT SYSTEM Three types of measurement are used to measure temperature: · Measurement by penetration (semi-solids, pasty samples, etc.) and by immersion (liquids). · Ambient measurement (air, gas). · Surface measurement (solid bodies). INFRARED THERMOGRAPHY Infrared thermography detection technology has become irreplaceable for ensuring safe conditions for industrial production. Infrared thermal imaging is a no-contact, real-time inspection method for production equipment subject to high voltages, powerful electric currents or high operating speeds. For this detection method, there is no need to cut off the current, shut down the machines or stop production. It can be used to troubleshoot any latent malfunctions in advance and thus prevent failures and avoid production incidents. Thermal imaging is an innovative technique for safe, reliable and quick "no-contact" assessment. A thermal camera does not measure temperatures but radiation fluxes. Once the operator has adjusted certain parameters, the camera calculates the temperatures of the target. It then provides the user with a map of the temperatures, called a thermogram: each temperature is represented by a different colour. ELECTRICAL MAINTENANCE The purpose of this sort of inspection is to detect any overheating in working electrical systems due to various causes: poor connections, overloads, phase unbalance, faulty contacts, etc. This helps to prevent and avoid costly equipment damage, production shutdowns, operating losses, fires, etc. The aim is to help with decision-making for corrective action, to prevent incidents, to anticipate any works which might be necessary and to facilitate electrical installation maintenance (time saving and safety). MECHANICAL MAINTENANCE Moving mechanical parts heat up quite normally due to friction. Infrared thermography reveals abnormal overheating due to wear, misalignment, lubrication problems, etc. For the latter type, users can choose a system with or without contact, depending on the application involved. The type of application will determine the instrument and the probe chosen. In general, thermocouples offer quick response times and wide measurement ranges. Sensors with resistive probes are usually slower, but they are also more accurate. The sensor selection criteria will depend on: · the milieu and the operating environment. · the temperature range. · the required accuracy. · the response time. It is used to complement vibratory analysis, which is much more time-consuming to set up. A single image gives a full health report on the electric motor, its power supply (cables), the bearings and, if necessary, the alignment. BUILDING THERMICS These applications of infrared thermography concern architects, heating and sanitary installers, heating operators, electricians, property companies, property experts, owners and insurers. With an infrared camera, it is easy to view the distribution of heat on the front of a building and it also possible to precisely locate heat losses due to faulty insulation. This helps to produce a thermal survey of the building. 1062 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com PHYSICAL & ENVIRONMENTAL MEASUREMENTS > INFO AND ADVICE > INDOOR AIR QUALITY PHYSICAL & ENVIRONMENTAL MEASUREMENTS INDOOR AIR QUALITY Whether in places open to the public (transport, administrative offices, schools, hospitals), professional buildings or private areas, our lifestyles mean we spend most of our time inside buildings. Human activity and construction, decoration and furnishing products (paints, floor and wall coverings, varnishes, etc.) are all potential sources of contamination and emit substances in the air. The theme of indoor air quality has only recently come into the spotlight and is a major issue because it affects the whole population. CARBON DIOXIDE (CO2) Carbon dioxide is an odourless, colourless, toxic gas produced by the combustion of carbon-based materials such as wood, oil, coal and their derivatives. It is also produced by human and animal respiration. Plants, meanwhile, extract CO2 from the air during photosynthesis, thus helping to maintain the natural equilibrium. However, the level of CO2 in outdoor air has shown a tendency to increase gradually. This gradual increase began with industrialization and the development of human activity (combustion of fossil fuels). WHY MEASURE IT? In indoor environments, the CO2 measurement represents the level of confinement, a sign of pollutant accumulation and insufficient air renewal in the premises. Links have been reveal between poor ventilation, leading to high levels of CO2, and a reduction in the educational capabilities of children tested with logic, reading and calculation exercises. A CO2 concentration in the air of more than 1,000 ppm can already cause the people in a room to suffer from somnolence, difficulties concentrating and sometimes headaches. THRESHOLD VALUES In volume terms, the proportion of CO2 in the air is 0.0375%, or 375 ppmv (parts per million by volume). In urban environments, it may be as high as 500 ppm. · 5500 to 1,000 ppm - Indoor air quality: Good · 1,000 ppm - Certain studies have shown an increase in asthma-related symptoms among children on average over a school day · 1,500 to 2,500 ppm - Indoor air quality: Poor (1,500 ppm is the regulatory limit usually specified, particularly for educational premises in the United Kingdom, Germany and Austria) · 2,500 to 5,000 ppm - Symptoms: headache, fatigue and loss of concentration · 5,000 ppm - Average concentration over 8 hours Occupational Exposure Limit in France and elsewhere MEASUREMENT PRINCIPLE The method used by the CA 1510 to measure CO2 levels is an NDIR (Non-Dispersive InfraRed) method. CO2 and other gases absorb IR radiation in a "specific" way. · A source emits an IR signal in a predefined cavity · The CO2 absorbs part of the light in the near-IR spectrum, thus reducing the intensity of the signal SENSOR POSITIONING AND RECOMMENDATIONS The measuring instrument should preferably be positioned between 50 cm and 2 m from the ground. In practice, it should be set up in a safe place with access to a power socket if necessary. The instrument should be kept at least 50 cm away from any intense heat sources (heating) and should be kept out of direct sunlight. The instrument must not be placed in the direct flow of air from outside (windows) or close to the entrance. The CO2 level varies during the day, depending on how many people are present, the activities involved and the efficiency of the air renewal system; for these reasons, functions for recording and for indicating any threshold overruns are crucial. IR source CO2 Detector Measurement cell TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3107 PHYSICAL & ENVIRONMENTAL MEASUREMENTS > CALIBRATORS > SELECTION GUIDE CHOOSE YOUR CALIBRATOR Measurement / Simulation J, K, T, E, R, S, B & N thermocouples Pt10, Pt50, Pt100, Pt200, Pt500 & Pt1000 resistive probes 4-20 mA 0-10V Voltage Up to 100 mV Up to 20 V Current Up to 24 mA Resistance 0.00 to 3200.0 CA 1621 page 109 CA 1623 page 109 CA 1631 page 110 1082 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com PHYSICAL & ENVIRONMENTAL MEASUREMENTS > TEMPERATURE CALIBRATORS > CA 1621 - CA 1623 CA 1621 - CA 1623 REF.: P01654621 REF.: P01654623 °C °F Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Large screen for easier reading · Instrument calibration without removing the sensors · Good grip due to its (205x97x45 mm) and weight (472 g) CA 1621: thermocouple sensor temperature calibrator capable of measuring and simulating: · up to 8 types of thermocouple: J, K, T, E, R, S, B and N · a voltage in mV CA 1623: resistive probe temperature sensor capable of measuring and simulating: · up to 7 types of resistive probes: Pt 10, Pt 50, Pt 100, Pt 200, Pt 500, Pt 1000, Pt 100 (JIS) · a resistance ADDITIONAL INFO · Power supply via mains lead available as an option: · Input: 100 V/240 V - 50/60 Hz 1.8 A · Output: 12 Vdc, 2 A max · Powered by batteries (6 x 1.5 V supplied) or via mains lead (option) CONTENTS · 1 calibrator · 1 soft case · 6 x 1.5 V LR06 batteries · CA 1621 delivered with 2 thermocouple adapters as well · CA 1623 delivered with 2 test cables and 2 crocodile clips as well ACCESSORIES / REPLACEMENT PARTS Mains power supply Pre-equipped MultiFix bag 120x245x60 See all the accessories on page 136 P01103057 P01298075 SPECIFICATIONS Input/output range -10 mV ... 100 mV Function Type J Type K Type T Type E Type R Type S Type B Type N Range -200 ... +1,200°C -200 ... +1,370°C -200 ... +400°C -200 ... +950°C -20 ... +1,750°C -20 ... +1,750°C +600 ... +1,800°C -250 ... +1,300°C CA 1621 Resolution 0.01 mV Resolution 0.1°C 0.1°C 0.1°C 0.1°C 1°C 1°C 1°C 0.1°C Accuracy ± (0.3°C + 10 V) ±(0.3°C +10 V) ±(0.3°C +10 V) ±(0.3°C +10 V) ±(1 °C +10 V) ±(1 °C +10 V) ±(1 °C +10 V) ±(0.3°C +10 V) Accuracy ± 0.025 % + 2 counts Reference junction error ± 0.3°C ± 0.3°C ± 0.3°C ± 0.3°C ± 0.3°C ± 0.3°C ± 0.3°C ± 0.3°C Range 0.00 ... 400.0 400.0 ... 1500.0 1500.0 ... 3200.0 Mode Range Pt10 385 Pt50 385 Pt100 385 Pt200 385 Pt500 385 Pt1000 385 Pt100 JIS -200 ... +800°C -200 ... +800°C -200 ... +800°C -200 ... +250°C +250 ... +630°C -200 ... +500°C +500 ... +630°C -200 ... +100°C +100 ... +630°C +200 ... +630°C CA 1623 4-wire measurement accuracy ± Simulation accuracy ± 0.15 0.1 0.1 0.5 0.5 1 1 2 Accuracy in °C 4-wire input 2-wire /3-wire input Output 0.7 1.0 0.7 0.33 0.5 0.33 0.2 0.3 0.2 0.8 1.6 0.8 0.3 0.6 0.3 0.4 0.9 0.4 0.2 0.4 0.2 0.2 0.5 0.2 0.2 0.5 0.3 Admissible excitation in mA 0.1 ... 0.5 0.5 ... 3.0 0.05 ... 0.8 0.05 ... 0.4 Admissible excitation in mA 0.1 ... 3.0 0.1 ... 3.0 0.1 ... 3.0 0.1 ... 3.0 0.05 ... 3.0 0.1 ... 3.0 0.1 ... 3.0 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3109 PHYSICAL & ENVIRONMENTAL MEASUREMENTS > PROCESS SIGNAL CALIBRATORS > CA 1631 CA 1631 REF.: P01654402 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS Voltage/current process signal calibrator to measure or provide: · a 0 24 mA DC current loop · a 0-20 V DC voltage loop SPECIFICATIONS CA 1631 Range Resolution Accuracy ± (% of reading + counts) 100 mV 0.01 mV 0.02% + 3 20 V 0.001 V 0.02% + 3 Input impedance: 2 M (rated value), < 100 pF Protection against overvoltages: 30 V Current delivered at 20 V: 1 mA Range Resolution Accuracy ± (% of reading + counts) 24 mA 0.001 mA 0.015 % + 3 Protection against overvoltages: 125 mA 250 V quick-response fuse Display as percentage: 0 % = 4 mA 100 % = 20 mA Source mode: 1,000 load at 20 mA for a battery voltage 6.8 V, (700 at 20 mA for a battery voltage between 5.8 and 6.8 V Simulation mode: external loop voltage condition: 24 V (rated value), 30 V maximum, 12 V minimum. Loop voltage supply: 24 V ± 10 % ADDITIONAL INFO · Power supply via mains lead available as an option: · Input:100 V/240 V - 50/60 Hz 1.8 A · Output: 12 Vdc, 2 A max · Powered by 6 x 1.5 V batteries (supplied) or via mains power cable (option) CONTENTS · 1 calibrator · 1 soft case · 6 x 1.5 V LR06 batteries · 2 test cables · 2 crocodile clips · 2 test probes ACCESSORIES / REPLACEMENT PARTS Mains power supply MultiFix bag 120x245x60 mm See all the accessories on page 136 P01103057 P01298075 1102 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com PHYSICAL & ENVIRONMENTAL MEASUREMENTS > THERMAL CAMERA FOR BODY TEMPERATURE MEASUREMENT > CA 1900 CA 1900 REF.: P01651902 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · ACCURACY: less than 0.5 °C · FAST: instantaneous temperature detection · NO CONTACT: measurement from up 1.5 metres away · AUDIBLE AND VISUAL ALERTS: doe any abnormally high temperature · ALARMS: fixed threshold or threshold based on the average of the people tested · PRACTICAL: tripod insert beneath the camera CONTENTS The CA 1900 thermal camera is delivered in a site-proof case with: · 4 NiMH batteries and battery charger · 1 micro SD HD card · 1 USB cable · 1 Bluetooth earpiece · 1 test report · 1 quick start guide SPECIFICATIONS Detector Type Frequency Sensitivity (N.E.T.D) Measurement fluctuation Temperature measurement Temperature range Accuracy Thermal imaging performance Field of view IFOV (spatial resolution) Focusing Minimum focal distance Real image Display mode Analysis functions Measuring tools Alarms Data storage Image presentation Image format Adjustment Image hold Image display Screen Power supply Type Recharging mode Battery life Environmental specifications Operating temperature Storage temperature range Humidity Compliance Fall resistance Shock resistance Vibration withstand Physical specifications Weight / Dimensions Interfaces Mounting on tripod General information Warranty CA 1900 160 x 120 UFPA microbolometer, 8 ~14 m 9 Hz 60 mK @ 30 °C (0.06 °C @ 30 °C) < 0.02 °C (with adaptive alarm) +30 °C to +45 °C ± 0.5 °C @ 37 °C 38° x 28° 4.1 mrad Fixed 30 cm Yes (320 x 240 pixels) Thermal image, real image 1 manual cursor + 1 automatic host spot detection function + Isotherm - Adaptive alarm based on a temperature difference compared with the average of the temperatures measured (up to 6 people) - Alarm on overrun of a temperature threshold set by the operator - Visual and audible indications of overruns (via the Bluetooth earpiece supplied) - Compatibility with Bluetooth hands-free kits or loudspeakers (profiles supported: HSP, HFP) On removable 2 GB micro SD card (approx. 4,000 images), up to 32 GB possible .png (thermal and real images saved simultaneously) Automatic or manual adjustment of the palette min. and max. Animated or fixed image Multiple palettes including high-contrast rainbow or black and white 2.8 inches NiMH rechargeable batteries with low self-discharge External (charger supplied) 9 hours (in normal conditions of use) -15 °C to +50 °C (-4 °F to +122 °F) -40 °C to +70 °C (-40 °F to +158 °F) 10 % to 95 % EN 61326-1: 2006 / EN 61010-1 Ed. 2 2 metres on all surfaces 25 G 2 G 700 g with rechargeable batteries / 225 x 125 x 83 mm - USB link and Mass Storage function: the product is then recognized as a USB key for easy image transfer - Bluetooth for connectivity with earpiece Yes, ¼'' insert on the camera 2 years TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3111 PHYSICAL & ENVIRONMENTAL MEASUREMENTS > THERMAL CAMERAS > CA 1950 CA 1950 REF.: P01651901 IP 54 8x0 80 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Battery life of up to 13 hours, start-up in just 3 seconds · Resistance to falls from up to 2 m without interrupting operation · Focus-free with 20° x 20° field of view · Voice annotations to record comments directly on the image (earpiece supplied) · Connectivity with current clamps and multimeters ADDITIONAL INFO · Thermal image and real image saved simultaneously. Image merge function available with the CAmReport software supplied · Numerous measuring tools: manual cursor, automatic detection, temperature profile, etc. · Built-in brightness sensor CONTENTS CA 1950 delivered in site-proof case with: · 4 NiMH batteries · 1 battery charger · 1 x 2 GB micro SD HD card · 1 USB cable · 1 Bluetooth earpiece · 1 CD-ROM containing the CAmReport software · 1 measurement report BMP SPECIFICATIONS CA 1950 Detector 80 x 80 Type UFPA microbolometer, 8 ~14 µm Frequency 9 Hz Sensitivity (N.E.T.D) 80 mK @ 30 °C (0.08 °C @ 30 °C) Temperature measurement Temperature range -20 °C to +250 °C Accuracy ±2 °C or ±2 % of the reading Imaging performance (thermal image) Field of view 20° x 20° IFOV (spatial resolution) 4.4 mrad Focusing Fixed Minimum focal distance 40 cm Real image Yes (320 x 240 pixels) Thermal imaging, real image with automatic parallax Display mode compensation. Image merge function available in the PC software Analysis functions 1 manual cursor + 1 automatic detection function + Measuring tools Min Max on adjustable area + temperature profile + Isotherm Parameter settings Emissivity, environmental temperature, distance, relative humidity Voice comments Yes via Bluetooth (earpiece supplied) Connectivity F407 & F607 clamps, MTX 3292, MTX 3293 Data storage On removable 2 GB micro SD card (approx. 4,000 images), up to 32 GB possible Image format .bmp (thermal and real images saved simultaneously) Image presentation Adjustment Automatic or manual adjustment of palette min-max Image hold Animated or fixed image Image display Multiple palettes Screen 2.8 inches Power supply Type NiMH rechargeable batteries with low self-discharge Recharging mode External (charger supplied) Battery life 13 hrs 30 mins (typical) / 50 % brightness, Bluetooth deactivated Environmental specifications Operating temperature -15 °C to +50 °C (-4 °F to +122 °F) Storage temperature range -40 °C to +70 °C (-40 °F to +158 °F) Humidity 10 % to 95 % Compliance EN 61326-1: 2006 / EN 61010-1 Ed. 2 Resistance to falls 2 metres on all surfaces Shock resistance 25 G Vibration withstand 2 G Physical specifications Weight / Dimensions 700 g with rechargeable batteries / 225 x 125 x 83 Ingress protection IP 54 Interfaces - USB link and Mass Storage function: the product is then recognized as a USB key for easy image transfer - Bluetooth for connectivity with earpiece (voice comments) and Chauvin Arnoux® Metrix® measuring instruments (F407, F607, MTX 3292, MTX 3293) Mounting on tripod Yes, ¼'' insert on camera General information Supplied as standard with automatic report generation Report generation software in .pdf or .docx (Word) format / Compatibility with W7, W8, 32 and 64 bits Warranty 2 years 112 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com PHYSICAL & ENVIRONMENTAL MEASUREMENTS > THERMAL CAMERAS > CA 1954 CA 1954 REF.: P01651904 54IP 16x0 120 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Unprecedented ! Battery life of up to 9 hours in continuous use · Resistance to falls from up to 2 m without interrupting operation · Focus-free with 38° x 28° field of view · Recovery of the data from other measuring instruments (current, humidity,dew point, etc.) · Practical: voice recording, integrated user-enhanceable emissivity table, folder organization by site ADDITIONAL INFO · Thermal image and real image saved simultaneously. Image merge function available in the CAmReport software supplied · Numerous measuring tools: manual cursor, automatic detection, temperature profile, etc. · Built-in brightness sensor CONTENTS CA 1954 delivered in a site-proof case with: · 4 NiMH batteries · 1 battery charger · 1 x 2 GB micro SD HD card · 1 USB cable · 1 Bluetooth earpiece · 1 CD-ROM containing the CAmReport software · 1 measurement report PNG SPECIFICATIONS CA 1954 Detector 160 x 120 Type UFPA microbolometer, 8 ~14 µm Frequency 9 Hz Sensitivity (N.E.T.D) 80 mK @ 30 °C (0.08 °C @ 30 °C) Temperature measurement Temperature range -20 °C to +250 °C Accuracy ±2 °C or ±2 % of the reading Imaging performance (thermal image) Field of view 38° x 28° IFOV (spatial resolution) 4.1 mrad Focusing Fixed Minimum focal distance 30 cm Real image Yes (320 x 240 pixels) Thermal image, real image with automatic parallax Display mode compensation. Image merge function available in the PC software Analysis functions 1 manual cursor + 1 automatic detection function + Measuring tools Min Max Avg on adjustable area + temperature profile + Isotherm Parameter settings Emissivity, environmental temperature, distance, relative humidity Voice comments Yes via Bluetooth (earpiece supplied) Connectivity CA 1821/22/23, CA 1246, CA 1227, F407, F607, MTX 3292, MTX 3293 Data storage On removable 2 GB micro SD card (approx. 4,000 images), up to 32 GB possible Image format .png (thermal images and real images saved simultaneously) Laser pointer Yes Presentation of the image Adjustment Automatic or manual adjustment of palette min-max Image hold Animated or fixed image Image display Multiple palettes Screen 2.8 inches Power supply Type NiMH rechargeable batteries with low self-discharge Recharging mode External (charger supplied) Battery life 9 hours (typical) / 50 % brightness, Bluetooth deactivated Environmental specifications Operating temperature -15 °C to +50 °C (-4 °F to +122 °F) Storage temperature range -40 °C to +70 °C (-40 °F to +158 °F) Humidity 10 % to 95 % Compliance EN 61326-1: 2006 / EN 61010-1 Ed. 2 Resistance to falls 2 metres on all surfaces Shock resistance 25 G Vibration withstand 2 G Physical specifications Masse 700 g with rechargeable batteries Dimensions 225 x 125 x 83 mm Indice de protection IP 54 Interfaces - USB link and Mass Storage function - Bluetooth for connectivity with earpiece (CA 1821/22/23, CA 1246, CA 1227, F407, F607, MTX 3292, MTX 3293) Montage sur trépied Yes, ¼'' insert on camera General information Report generation software Supplied as standard with automatic report generation (.pdf / .docx) Compatibility with W7, W8, W10, 32 and 64 bits Warranty 2 years TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3113 PHYSICAL & ENVIRONMENTAL MEASUREMENTS > THERMOGRAM ANALYSIS SOFTWARE > CAmReport CAmReport C.A C.A 1950 1954 PDF Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Dedicated to the CA 1950 and CA 1954 models · Supplied as standard at no extra cost · Complete, with all the necessary functions for reliable analysis of your measurement results · Automatic generation of analytical reports exportable in word or pdf format PRECISE ANALYTICAL TOOLS · Cursors (automatic display of the temperature at the chosen point) · Thermal profile (automatic display of the Min/Max/Avg temperatures on the line) · A square or circle for analysis by zone · Polygons and polylines for more precise analysis of certain areas of the thermogram · Result tables quickly and automatically display all the information · Recovery of the voice comments or online measurements · Automatic merging of the thermal and real images saved simultaneously · Automatic report creation for export in .pdf or .docx format LANGUAGES AVAILABLE French, English, German, Spanish, Italian, Dutch, Polish, Romanian, Czech, simplified Chinese, Portuguese, Swedish, Finnish REQUIRED CONFIGURATION WINDOWS XP: · SP3 minimum · 850 MB memory for 32 bit · 2 G for 64 bit · NET Framework 4.0 minimum · Monitor resolution: super VGA (800 x 600) or higher WINDOWS VISTA / 7 / 8 / 10: · SP1 minimum · 850 MB memory for 32 bit · 2 G for 64 bit · NET Framework 4.0 minimum 1142 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com PHYSICAL & ENVIRONMENTAL MEASUREMENTS > THERMOGRAM ANALYSIS SOFTWARE > CAmReport · Reports are generated automatically according to various templates available. · They can be exported in Word or pdf format. This makes it simpler to print and archive. TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3115 PHYSICAL & ENVIRONMENTAL MEASUREMENTS > THERMOMETERS > SELECTION GUIDE CHOOSING YOUR THERMOMETER CA 1871 CA 1860 CA 1862 CA 1864 CA 1866 CA 876 CA 1821 CA 1822 CA 1823 TK 2000 TK 2002 page 118 Infrared measurement page 117 page 117 page 117 page 117 page 118 page 120 page 120 page 121 page 119 page 119 Field of view 8/1 10/1 12/1 30/1 50/1 Emissivity Fixed: 0.95 Variable: 0.1 to 1 Laser sight Contact measurement 1-input thermocouple sensor 2-input thermocouple sensor 1-input resistive probe General functions HOLD Max Min Avg Alarm Choice of units Backlighting Double J, K, T, N, E, J, K, T, N, E, R, S R, S K K J, K, T, N, E, R, S K Pt100 Pt1000 via Data Logger Transfer via Data Logger Transfer via Data Logger Transfer 1162 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com PHYSICAL & ENVIRONMENTAL MEASUREMENTS > NO-CONTACT THERMOMETERS > CA 1860 - CA 1862 | CA 1864 - CA 1866 CA 1860 - CA 1862 REF.: P01651815 REF.: P01651816 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology IP 65 °C °F IR CA 1864 - CA 1866 REF.: P01651813 REF.: P01651814 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology °C °F IR Diagram of the "Field of View" CA 1864 D/S: 30/1 Distance (D) / Spot size (S) Laser beam 10 to 300 mm30 to 900mm 50 to 1500mm Sensor beam STRENGTHS · Compact and rugged thanks to its resistance to falls from up to 3 metres and IP65 ingress protection · Excellent metrological performance · Wide dynamic range for measurement: -35 °C to +650 °C · Double LASER sight (CA 1862) for precise targeting of the test area · Parameterizable high and low alarms SPECIFICATIONS Measurement range Measurement accuracy Display resolution Field of view Emissivity Response time Spectral response Number of lasers Measurement functions Type of battery Protection Resistance Tripod insert Weight/dimensions CA 1860 CA 1862 - 35 °C to + 450 °C (- 31 °F to + 842 °F) - 35 °C to + 650 °C (- 31 °F to + 1202 °F) 0° C: ± 1.8 °C or ± 1.8 % of reading (take the higher value) < 0 °C: ± (1.8 °C + 0.1 °C / °C) 0.1 °C (0.1 °F) 10: 1 12: 1 0.95 Adjustable from 0.1 to 1.0 250 ms (95 % of reading) 8 µm ~14 µm Single laser Double laser Instantaneous mode, MAX, MIN, AVG, differential (DIF), continuous measurement by blocking the measurement trigger, alarms 9V battery (6F22) IP65 Falls from 3 metres Yes 292 g / 189 mm x 118 mm x 55 mm CONTENTS The CA 1860 and CA 1862 are delivered with: · 1 carrying bag · 1 x 9 V LR14 battery STRENGTHS · Extended temperature range: measure up to 1,000 °C · Use the variable emissivity to perform your inspections in accordance with reality · High distance/spot ratio for better accuracy at long distances · Set your alarm thresholds so that you are alerted every time there is an abnormal temperature! SPECIFICATIONS Field of view Emissivity Measurement range Resolution Accuracy Functions Alarms Measurement unit Laser sight Display Dimensions / weight CA 1864 CA 1866 30/1 50/1 0.1 to 1 - 50 °C to +1000 °C 0.1 °C - 50 °C to - 20 °C: ± 5 °C - 20 °C to +200 °C: ±1.5 % R + 2 °C +200 °C to +538 °C: ±2.0 % R + 2 °C +538 °C to +1000 °C: ±3.5 % R ± 5 °C Max., Min., Avg., DIFF, HOLD High and low °C, °F Yes, Class II laser 20,000 counts, backlighting 230 x 100 x 56 mm / 290 g ACCESSORIES / REPLACEMENT PARTS 9 V LR14 battery Soft case P01100620 P01298033 CONTENTS The CA 1864 and CA 1866 are delivered with: · 1 carrying bag · 1 x 9 V LR14 battery TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3117 PHYSICAL & ENVIRONMENTAL MEASUREMENTS > NO-CONTACT THERMOMETER > CA 1871 | CA 876 CA 1871 REF.: P01651610Z °C IR Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology CA 876 °C °F IR REF.: P01651403Z Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Rugged thanks to their shockproof protective sheath · Temperature measurement up to 1,350 °C · Measurement accuracy · Stability of the sensor over time · Infrared measurement possible STRENGTHS · Infrared probe suitable for use with all multimeters · Point the probe at the surface of the object. The sensor supplies a voltage proportional to the temperature measured (1 mV / °C) SPECIFICATIONS Field of view Emissivity Measurement range Accuracy Dimensions / weight CA 1871 8/1 Fixed 0.95 - 30 °C to + 550 °C ± 2 % of reading 164 x 50 x 40 mm / 182 g SPECIFICATIONS Field of view Emissivity Measurement range Accuracy Functions Dimensions / weight CA 876 IR measurement Contact measurement 10/1 - 0.1 to 1 - - 20 °C to + 550 °C - 40 °C to + 1,350 °C ± 2 % R or ± 3 °C ± 0.1 % R +1 °C Max., Min., Avg., HOLD, Alarms 173 x 60.5 x 38 mm / 255 g CONTENTS · 1 shockproof sheath · 1 flexible K thermocouple sensor CONTENTS The CA 1871 is delivered with: · 1 x 9V LR14 battery ACCESSORIES / REPLACEMENT PARTS K thermocouples CK extensions page 134 page 135 1182 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com PHYSICAL & ENVIRONMENTAL MEASUREMENTS > CONTACT THERMOMETERS > TK 2000 - TK 2002 TK 2000 - TK 2002 REF.: P01653100 REF.: P01653110 IP 65 °C Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Compact, accurate and simple to use: just connect the sensor and start measuring! · Usable in all environments thanks to their IP 65 protection · Measures the temperature difference by means of the 2 thermocouple inputs on the TK 2002 SPECIFICATIONS No. of inputs Range Accuracy Functions Dimensions Weight TK 2000 TK 2002 1 2 - 50 °C to +1000 °C ± 1.5 % + 0.5 °C HOLD, °C 163 x 63 x 37.5 mm 200 g CONTENTS · 1 battery TK 2000 delivered with: · 1 flexible K thermocouple sensor · 1 x 9 V 6LR61 battery TK 2002 delivered with: · 2 flexible K thermocouple sensors · 1 pile 9 V 6LR61 ACCESSORIES / REPLACEMENT PARTS K thermocouples CK extensions page 134 page 135 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3119 PHYSICAL & ENVIRONMENTAL MEASUREMENTS > CONTACT THERMOMETERS > CA 1821 - CA 1822 CA 1821 - CA 1822 REF.: P01654821 REF.: P01654822 °C °F Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · J, K, T, N, E, R, S thermocouples · Recording of up to 1 million points · Magnetized product compatible with MultiFix · USB and Bluetooth communication · Backlit digital display ADDITIONAL INFO · Shockproof sheath available as an accessory · Compatible with the Data Logger Transfer module of the Dataview® software for: - data display - programming of recordings - automatic export of the report CONTENTS CA 1821 and CA 1822 delivered with: ·1 carrying bag ·3 x 1.5 V LR6 batteries ·1 USB cable ·1 measurement report SPECIFICATIONS CA 1821 CA 1822 Sensor J, K, T, N, E, R or S thermocouple No. of inputs 1 2 Range J: 210 to + 1,200 °C / 346 to + 2,192 °F K: 200 to + 1,372 °C / 328 to + 2,501 °F T: 250 to + 400 °C / 418 to + 752 °F N: 200 to + 1,300 °C / 328 to + 2,372 °F E: 150 to + 950 °C / 238 to + 1,742 °F R 0 to + 1,767 °C / 32 to + 3,212 °F S 0 to + 1,767 °C / 32 to + 3,212 °F Resolution Display in °C: < 1,000 °C: 0.1 °C and 1,000°C: 1 °C Display in °F: < 1,000 °F: 0.1 °F and 1,000°F: 1 °F Accuracy (J. K. T. N. E) - 100°C ± (0.2% Reading + 0.6°C) - 100°C < + 100°C ± (0.15% R + 0.6°C) + 100°C < ± (0.1% R + 0.6°C) (R. S) + 100°C ± (0.15% R + 1.0°C) + 100°C < ± (0.1% R + 1.0°C) Functions Min., Max., HOLD, alarms, temperature differential (CA 1822) Recording Manual Start / Stop on the product Programmed recording Alarms Visual alert on threshold overrun set via Data Logger Transfer Recording can be triggered on alarm threshold Data storage More than 1 million points Power supply - 3 x 1.5V LR6 alkaline batteries or NiMH rechargeable battery - Mains connection possible with the mains / micro USB adapter (option) Battery life 1,000 hrs (portable mode) / 3 years for recording (15-minute measurement interval) Dimensions/weight 150 x 72 x 32 mm / 260 g with batteries Ingress protection IP54 casing Operating temperature / humidity -10 to +60 ° C - 10 to 90 % RH Standards IEC 61010-1 - IEC 61326-1 ACCESSORIES / REPLACEMENT PARTS Thermocouple Shockproof sheath + MultiFix accessory CK extensions See all the accessories on page 136 page 134 P01654252 page 135 1202 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com PHYSICAL & ENVIRONMENTAL MEASUREMENTS > CONTACT THERMOMETERS > CA 1823 CA 1823 REF.: P01654823 °C °F Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Pt100 or Pt1000 resistance probe · Recording of up to 1 million points · MultiFix-compatible magnetized product · USB and Bluetooth communication · Backlit digital display ADDITIONAL INFO · Shockproof sheath available as an accessory · Compatible with the Data Logger Transfer module of the Dataview® software for: - data display - programming of recordings - automatic export of the report SPECIFICATIONS Sensor No. of inputs Range Resolution Accuracy Functions Recording Alarms Data storage Power supply Battery life Dimensions/weight Ingress protection Operating temperature / humidity Standards CA 1823 Pt100 or Pt1000 probe 1 -100 to +400 °C -148 to +752 °F Display in °C: 0.1°C Display in °F: 0.1°F ± (0.4 % R +0.3 °C) Min., Max., HOLD, Alarms Manual Start / Stop on the product Programmed recording Visual alert on threshold overrun set via Data Logger Transfer Recording can be triggered on alarm threshold More than 1 million points 3 x 1.5V LR6 alkaline batteries or NiMH rechargeable battery Mains connection possible with the mains / micro USB adapter (option) 800 hours (portable mode) / 3 years for recording (15-minute measurement interval) 150 x 72 x 32 mm / 260 g with batteries IP54 casing -10 to +60 ° C - 10 to 90 % RH IEC 61010-1 for 50 V voltages in Category II - IEC 61326-1 CONTENTS CA 1823 delivered with: ·1 carrying bag ·3 x 1.5 V LR6 batteries ·1 USB cable ·1 measurement report ACCESSORIES / REPLACEMENT PARTS Thermocouples Shockproof sheath + MultiFix accessory CK extensions See all the accessories on page 136 page 134 P01654252 page 135 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3121 PHYSICAL & ENVIRONMENTAL MEASUREMENTS > THERMO-HYGROMETERS > CA 1246 | CA 847 CA 1246 %RH °C °F REF.: P01654246 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Hygrometry, temperature and dew point · Recording up to 1 million points · Visual alarm on threshold overrun · MultiFix-compatible magnetized product · Recording trigger on alarm threshold CA 847 REF.: P01156302Z Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Measure the humidity of wood very simply: prick the material and note the value corresponding to the LED which lights up. SPECIFICATIONS RH range RH accuracy Temp. range °C/°F Temp. accuracy °C/°F Dew point range Dew point accuracy Functions Recording Alarms Data storage Power supply Battery life Dimensions / weight Ingress protection Operating temperature / humidity Standards CA 1246 3 to 98 % RH 10 to 90 %RH: ± (2 %RH ± 1 ct) outside that range: ± (4 %RH ± 1 ct) -10 to +60 °C +14 to +140 °F 10 to 40°C: ± (0.5°C ± 1 ct) outside that range: ± (0.032 x (T-25) ± 1 ct) / T=temperature in °C -10 to +60 °Ctd -4 to + 140 °Ftd 1.5 °C from 20 % RH to 30 % RH 1 °C above 30 % RH Min., Max., HOLD, Alarms Manual Start / Stop on the product Programmed recording Visual alert on threshold overrun set via Data Logger Transfer Recording can be triggered on alarm threshold More than 1 million points 3 x 1.5V AA / LR6 alkaline batteries or NiMH rechargeable battery Mains connection possible with the mains / micro USB adapter (option) 1,000 hrs (portable mode) / 3 years for recording (15-minute measurement interval) 187 x 72 x 32 mm / 260 g with batteries IP54 casing -10 to +60 ° C / 10 to 90 % HR IEC 61010-1 - IEC 61326-1 ADDITIONAL INFO · Compatible with the Data Logger Transfer module of the Dataview® software for: - data display - programming of recordings - automatic export of the report SPECIFICATIONS RH range RH accuracy Dimensions Weight CA 847 6 to 100% HR ±1 LED 173 x 60.5 x 38mm 160 g CONTENTS The CA 847 is delivered with 1 x 9 V 6LR61 battery CONTENTS CA 1246 delivered with: ·1 carrying bag ·3 x 1.5 V LR6 batteries ·1 USB cable ·1 measurement report ACCESSORIES / REPLACEMENT PARTS 75 % salt cartridge 33 % salt cartridge See all the accessories on page 136 P01156401 P01156402 122 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com PHYSICAL & ENVIRONMENTAL MEASUREMENTS > THERMO-ANEMOMETERS | MANOMETERS > CA 1227 | CA 850 - CA 1550 CA 1227 REF.: P01654227 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology m/s m3/s km/h m3/h °C °F CA 850 - CA 1550 REF.: P01184101 REF.: P01654550 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Temperature, air speed and air flow rate · Mapping of measured air speeds (MAP mode) · Min, Max, Average and Hold functions · Recording up to 1 million points SPECIFICATIONS Air speed / flow rate sensor Air speed range Air speed accuracy Air flow rate range Air flow rate accuracy Temp. range °C/°F Temp. accuracy °C Functions Recording Data storage Power supply Battery life Dimensions Weight Ingress protection Operating temperature / humidity Standards CA 1227 Rotating vane with optical detection 0.25 m/s to 35.0 m/s (49.0 to 6890.0 fpm) ± 3 % of reading ± 4 cts 0 to 2,999 m3/h ± 8 % of reading - 20 to +50 °C / -4 to +122 °F 0 to 50 °C: ± 0.8 °C -20 to 0 °C: ± 1.6 °C Min., Max., HOLD, Average Manual Start / Stop on the product Programmed recording More than 1 million points - 3 x 1.5V LR6 alkaline batteries or NiMH rechargeable battery - Mains connection possible with the mains / micro-USB adapter offered as an accessory 200 hrs (portable mode) / 8 days of recording (measurements at 15-minute intervals) Casing: 150 x 72 x 32 mm Sensor: 160 x 80 x 38 mm Spiral cable: 24 to 120 cm Approx. 400 g IP40 casing -10 to +60 ° C / 10 to 90 % HR IEC 61010-1 - IEC 61326-1 ADDITIONAL INFO · Compatible with the Data Logger Transfer module of the Dataview® software for: - data display - programming of recordings - automatic export of the report CONTENTS CA 1227 delivered with: ·1 carrying bag ·3 x 1.5 V LR6 batteries ·1 USB cable ·1 measurement report STRENGTHS · Accurate and simple to use · Time/date-stamped monitoring · Differential measurements SPECIFICATIONS Measurement range Accuracy Unit Functions Dimensions Weight CA 850 CA 1550 -6.89 to +6.89 bar - 2,450 to + 2,450 Pa 0.5 % at full scale psi, bar, mbar, mmH2O, inH2O kbar, cmH2O, FtH2O, mmHg, OZin2, kg/cm2 Pa, PSI, DaPa, hPa, mbar, mmHg, inHg, mmH2O, inH2O m/s et km/h, fpm et mph m3/s, m3/h, l/s ou cfm Differential measurements, Min., Max., HOLD 182 x 72 x 30 mm 150 x 72 x 32 mm 220 g 260 g CONTENTS CA 850 delivered with: ·1 hard case ·2 connection tubes ·1 x 9 V 6LR61 battery CA 1550 delivered with: ·1 carrying bag ·3 x 1.5 V AA alkaline batteries ·2 transparent connection hoses, ·1 USB cable ·1 test report and Quick Start Guide ACCESSORIES / REPLACEMENT PARTS Cones kit for flow-rate measurement with rotating vane (circular cross-section Ø 210mm and rectangular cross-section 346x346mm) Vane sensor Ø 80 mm See all the accessories on page 136 P01654250 P01654251 ACCESSOIRES / RECHANGES Pitot tube (length 324 mm, Ø 6 mm fitting, Ø at tube mouth 8 mm) Transparent hose (Internal Ø 5 mm, length 2 metres) TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com P01654560 P01654561 3123 PHYSICAL & ENVIRONMENTAL MEASUREMENTS > SOUND LEVEL METERS > CA 832 - CA 1310 CA 832 REF.: P01185501Z dBA dBC Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology CA 1310 REF.: P01651030 dBA dBC Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Sound level testing · Simple to use SPECIFICATIONS Measurement range Frequency range Accuracy (in reference conditions at 94 dB, 1 kHz) Frequency weighting Time weighting Function CA 832 37.0 to 130.0 dB 31.5 Hz to 8 kHz ± 2 dB A / C FAST: 125 ms / SLOW: 1 second Measurement modes MaxL (Maximum sound level) Leq (equivalent continuous sound level) integration time Recording Display Physical specifications Tripod insert Dimensions / weight General specifications Compliance Warranty Digital Yes 237 x 60.5 x 38 mm (230 g) IEC 651 type 2 2 year Software No CONTENTS CA 832 delivered with: ·1 shockproof sheath ·1 jack socket for analogue output ·1 universal adapter for mounting on tripod ·1 x 9 V 6LR61 battery STRENGTHS · Measurement of the equivalent continuous sound level (Leq) · Recording of up to 64,000 measurement points with data processing software supplied as standard · Wide backlit screen with digital and bargraph display · Microphone for remote use (extension accessory) SPECIFICATIONS Measurement range Frequency range Accuracy (in reference conditions at 94 dB, 1 kHz) Frequency weighting Time weighting Function Measurement modes Leq (equivalent continuous sound level) integration time Recording Display Physical specifications Tripod insert Dimensions / weight General specifications Compliance Warranty Software CA1310 30.0 to 130.0 dB 20 Hz to 8 kHz ± 1 dB A / C FAST:125 ms / SLOW: 1 second SPL (Sound Pressure Level) Leq (Equivalent Continuous Sound Level) MaxL (Maximum Equivalent Sound Level) MinL (Minimum Sound Level) Available values: 10 sec, 1 min, 5 min, 10 min, 15 min, 30 min, 1 h, 8 h, 24 h 64 000 points Digital and bargraph Time/date-stamping Yes 262 x 75 x 39 mm / 390 g IEC 61672-1 Class 2 2 years SL-Software: - Values displayed in graph or table format - Data export - Real-time mode CONTENTS CA 1310 delivered in a hard case with: ·batteries ·foam wind shield ·software on CD-Rom ·1 male jack socket ·user's manual ·verification certificate 1242 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com PHYSICAL & ENVIRONMENTAL MEASUREMENTS > LUXMETER > CA 1110 CA 1110 REF.: P01654110 LUX FC CLASS C NF C 42-710 LED FLUO Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Totally compliant lighting measurement in all directions · Measures up to 200,000 lux · Mapping of lighting measured for an area or room (MAP mode) · Metrological compensation on Fluo LEDs. · Min., Max., Avg. and HOLD · Recording up to 1 million points ADDITIONAL INFO · Compatible with the Data Logger Transfer module of the Dataview® software for: - data display - programming of recordings - automatic export of the report ACCESSORIES / REPLACEMENT PARTS Shockproof sheath + MultiFix accessory Mains adapter See all the accessories on page 136 P01654252 P01651023 SPECIFICATIONS Measurement range Accuracy in standard mode Incandescent lamp LED Fluorescent lamp Accuracy in compensation mode LED mode Fluo mode Functions Recording MAP mode Data storage Power supply Battery life Dimensions Weight Ingress protection Operating temperature / humidity Standards CA 1110 0.1 to 200 000 lx 0.01 to 18 580 fc ± 3 % of reading ± 6 % of reading (3,000 K to 6,000 K) ± 9 % of reading ± 4 % of reading (at 4000 K) ± 4 % of reading (type F11, 4000 K) Min., Max., HOLD, Average Manual Start / Stop on the product Programmed recording The MAP function can be used to map the lighting on a surface or in a room. In this way, the lighting measurements are saved in the same file. More than 1 million points - 3 x 1.5V AA / LR6 alkaline batteries or NiMH rechargeable battery - Mains connection possible with the mains / micro USB adapter (option) 500 hours (portable mode) / 3 years of recording (15-minute measurement interval) Casing: 150 x 72 x 32 mm Sensor: 67 x 64 x 35 mm (with protective cover) Spiral cable: 24 to 120 cm 345 g with batteries Casing IP50 -10 to +60 ° C / 10 to 90 % RH Class C as per the NF C 42-710 standard CONTENTS CA 1110 delivered with: ·1 carrying bag ·3 x 1.5 V LR6 batteries ·1 USB cable ·1 measurement report TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3125 PHYSICAL & ENVIRONMENTAL MEASUREMENTS > TACHOMETERS > CA 1725 - CA 1727 CA 1725 - CA 1727 REF.: P01174810 REF.: P01174830 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Measurements up to 100,000 RPM · Measurement with and without contact · Multiple functions available: rotation speed, linear speed, counting, frequency, period · Possibility of programming and storage capacity CA 1727 · USB connection to process the recordings on PC with the CA 1727 SPECIFICATIONS RPM function Range Accuracy m/min function Range Accuracy Hz function Range Accuracy ms functions Range Accuracy Duty cycle function Range Accuracy Counting function Range Accuracy Functions Data storage Dimensions Weight CA 1725 CA 1727 60 to 100,000 rpm 10-4 of reading ± 6 cts 60 to 10,000 m/min. 10-4 of reading ± 1 increment 1 to 10,000 Hz 4 x 10-5 of reading ± 4 cts 0.1 to 1000 ms 10-4 of reading ±5 cts 0.1 to 100 % 0.1 % to 1 % - 0 to 100,000 events - ± 1 event Min., Max., HOLD, Smooth - High and low alarms - 4,000 points 21 x 72 x 47 mm 250 g ACCESSORIES / REPLACEMENT PARTS Mechanical accessories kit End-fittings (set of 3) See all the accessories on page 136 P01174902 P01174903 CONTENTS CA 1725 delivered with: ·1 hard case ·1 FRB F connector ·1 x 9 V LR14 battery ·1 set of 15 strips of reflective tape (0.1 m long) ·1 CD-ROM containing the user's manual CA 1727 delivered with: ·1 hard case ·1 FRB F connector ·1 x 9 V LR14 battery ·1 set of 15 strips of reflective tape (0.1 m long) ·1 CD-ROM containing the TACHOGRAPH software 1262 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com PHYSICAL & ENVIRONMENTAL MEASUREMENTS > STROBOSCOPE | CO DETECTOR > CDA 9452 - CA 895 CDA 9452 REF.: P03197704 Flashes /min Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology CA 895 REF.: P01651001Z ppm CO Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Frequency or speed measurement without contact with rotating parts · Digital frequency display · Quartz time base · White flash lamp, 40 joules SPECIFICATIONS LED display Measurement range Resolution Accuracy Power supply Climatic conditions Dimensions Weight CDA 9452 10,000 counts 100... 1,000 flashes/min 1,000... 10,000 flashes/min 1 flash/min 0.05 % 220 V 50/60 Hz 0... + 50 °C / RH < 80 % 210 x 120 x 120 mm 1 kg ADDITIONAL INFO ·When the flashes from the stroboscope are directed at an object moving periodically and have the same frequency as the phenomenon observed, the object appears immobile. All you then need to do is read the frequency expressed in flashes/minute on the CDA 9452. To obtain the frequency in Hz, simply divide the reading by 60. CONTENTS CDA 9452 delivered with mains power cable STRENGTHS · Measures the level of carbon monoxide present in a room · Checks the operation of combustion equipment · Warning buzzer to indicate when there is a risk SPECIFICATIONS Measurement range Accuracy Measurement mode Functions Dimensions Weight CA 895 0 to 1,000 ppm ± 5 % + 5 ppm Normal or Avg. Alarm, Max., HOLD 237 x 60.5 x 38 mm 190 g CONTENTS CA 895 delivered with: · 1 shockproof protective sheath · 1 x 9 V LR14 battery ACCESSORIES / REPLACEMENT PARTS Aspiration kit with pump and extension P01651101 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3127 PHYSICAL & ENVIRONMENTAL MEASUREMENTS > CO2 - TEMPERATURE - HUMIDITY LOGGER > CA 1510 °C °F RH CA 1510 ppm REF.: P01651011 CO2 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · CO2, temperature and humidity logger (up to 1 million points) · Compact: for fixed or portable use · User-friendly: thanks to the comfort-level indicators based on the level of CO2 and hygrothermal criteria · Accurate: complies with the latest regulations on air-quality monitoring · Low gas consumption thanks to its in-situ calibration kit ADDITIONAL INFO · CA 1510 also available in black..... P01651010 · Delivered in a metal case CONTENTS Delivered in a neutral cardboard box: ·2 x 1.5 V LR06 batteries ·1 USB mains adapter ·1 USB-micro USB cable ·1 desk stand ·Software ·User's manual (5 languages) on CD-ROM ·1 verification certificate SPECIFICATIONS CA 1510 Specifications for CO2 Measurement range 0 to 5,000 ppm Accuracy ± 50 ppm ± 3% of measured value Resolution 1 ppm Temperature measurement Measurement range -10°C to +60°C Accuracy ± 0.5 °C Resolution 0.1°C Humidity Measurement range 5 to 95 % RH Accuracy ± 2% RH Resolution 0.1% RH Possibilities of the product Portable measurement Quick measurement and display of the CO2, temperature and relative humidity values Indicator Energy saving (ECO) 1D mode: CO confinement indication 2 Visual indication (two-colour backlighting and pictograms) and/or audible indication of high confinement when the CO2 concentration is between 1,000 ppm and a 1,700 ppm threshold. 3D mode: indication of optimum comfort zone on the basis of hygrothermal criteria and the CO concentration 2 For fixed use on battery power, the product performs measurements every 10 minutes over a programmable time range for a battery life of up to one year Logger Activation of programmed recording (P_REC) The start date, recording rate and end date can be customized with the PC software or the Android application. Possibility of locking the display in this mode (no values displayed). Manual activation (M_REC) Manual start and stop controls on the product. Recording is performed at the rate of the mode currently selected. Specifications Recording rate Customizable from 1 minute to 2 hours Data storage More than 1 million points Buzzer and units Yes / °C or °F Backlighting / Hold / Min Max Yes Dimensions / weight 125 x 65.5 x 32 mm / 190 g with batteries Power supply Batteries: 2 x 1.5 V AA / LR6 or rechargeable battery Connection to mains possible with mains / micro USB adapter supplied as standard Interfaces 2 communication modes possible: Bluetooth wireless communication and USB link; the product is then recognized as a USB key for easy file transfer Mounting CA 1510 casing equipped with a magnet, a wall-suspension system and a slit for hanging the product. A wall support for use with a padlock (padlock not supplied) is available as an accessory, as is a desktop stand (supplied as standard with the CA 1510W). Processing software supplied as standard Representation in graph or table format / Data export - Real-time mode / Report generation ACCESSORIES / REPLACEMENT PARTS In-situ calibration kit Metal case See all the accessories on page 136 P01651022 P01298071 1282 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com PHYSICAL & ENVIRONMENTAL MEASUREMENTS > RADIOFREQUENCY & MICROWAVE MEASUREMENTS > CA 40 | CA 7028 CA 40 REF.: P01167501 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology CA 7028 RJ REF.: P01129501 45 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology LAN TESTER LOW-FREQUENCY FIELDMETER STRENGTHS · Measurement of low-frequency magnetic fields · Quick assessment of the radiation from equipment and installations · Easy-to-handle unidirectional probe SPECIFICATIONS Magnetic field measurement Accuracy Frequency range Power density Output Probe Alarm Data storage Dimensions Weight 20 T ±(4 %+3 cts) CA 40 200 T ±(5 %+3 cts) 30 to 300 Hz Unidirectional 163 x 68 x 24 mm 285 g 2000 T ±(10 %+5 cts) ACCESSORIES / REPLACEMENT PARTS Soft case P01298036 CONTENTS · 1 probe · 1 x 9 V 6LR61 battery STRENGTHS · Graphical screen · Detects, identifies and locates faults from up to 150 m away. · Designed for use on UTP, STP, FTP, & SSTP cables equipped with RJ45 connectors and wired in compliance with the TIA 568A/B, USOC or ISDN specifications SPECIFICATIONS Connector Types of cables Faults indicated Remote modules Dimensions Weight CA 7028 RJ 45 UTP, STP, FTP & SSTP Short-circuited pair, Wire in open circuit, Short-circuit between pairs, Crossed pairs, Reversed pairs, Shielding continuity Identifiers nos. 1 to 9 165 x 90 x 37 mm 350 g ACCESSORIES / REPLACEMENT PARTS Set of 4 identifiers nos. 2 to 5 Set of 4 identifiers nos. 6 to 9 See all the accessories on page 150 P01101994 P01101995 CONTENTS CA 7028 delivered with: ·2 x RJ45 cables ·1 identifier no. 1 ·1 soft case ·4 x 1.5 V LR06 batteries TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3129 PHYSICAL & ENVIRONMENTAL MEASUREMENTS > DATA PROCESSING SOFTWARE > DATAVIEW® DATAVIEW® REF.: P01102095 Data Logger Transfer Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology FUNCTIONS · Configuration of all the functions of instruments connected to a PC or via Bluetooth · Display of the data in table and graph form · Export to an Excel spreadsheet or jpeg image · Programming of recordings (date and rate) · Automatic export of reports in Word format REQUIRED CONFIGURATION · Windows Vista & Windows 7/8/10 (32/64 bit) · 1 GB RAM for Windows Vista & Windows 7/8 (32 bit) · 2 GB RAM for Windows Vista & Windows 7/8 (64 bit) · 80 MB available space on hard disk (200 MB recommended) DataView® modules ADDITIONAL INFO · Totally configurable alarms and recordings on alarms ·The Dataview® software automatically recognizes the instrument connected when it is hooked up to the PC and launches the corresponding menu. Users then have direct access to its configuration and to the stored data. Related products Data Logger Transfer CA 1821 CA 1822 CA 1823 CA 1246 CA 1227 CA 1110 CA 1510 CA 10001 CA 10101 CA 10141 1302 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com PHYSICAL & ENVIRONMENTAL MEASUREMENTS > pH/TEMPERATURE TESTER > CA 10001 - CA 10002 ELECTROCHEMISTRY INFO AND ADVICE pH The term pH The concept of pH was introduced in 1909 by S.P.L. Sørensen who described it as the measurement of the degree of acidity or alkalinity (basicity) of an aqueous solution. The pH is defined as the inverse of the decimal logarithm of the hydrogen ion concentration. pH = -log[H+] A high concentration of H+ protons therefore indicates a very acidic pH and a low concentration of protons indicates a basic pH. The conventional pH range is from 0 to 14. Potentiometric measurement of pH The pH measurement involves two electrodes: the indicator electrode, which is pHsensitive, and the reference electrode. To measure the pH of a solution, you must determine the difference in potential between these two electrodes. These electrodes are often grouped within a single enclosure to obtain a single electrode called a combination electrode. The response of the indicator electrode depends on the concentration of H+ ions and it sends a signal proportional to the solution's degree of acidity/basicity. The reference electrode is not sensitive to the H+ ion concentration, so it delivers a constant potential which serves as a reference to measure the potential of the pH (or indicator) electrode. The difference in potential generated is therefore proportional to the pH of the measurement medium (Nernst's equation). CONDUCTIVITY The concept of conductivity Electrical conductivity is the capacity of a solution, a metal or a gas to allow an electric current to flow. The transmission of electricity through matter requires charged particles. In a solution, it is the anions and cations which carry the current, whereas in metal, it is the electrons. A solution's conductivity depends on 4 factors: concentration of the ions, mobility of the ions, valence of the ions and temperature. Measurement principle of a conductivity meter The measurement system is composed of a conductivity cell, a temperature sensor and a conductivity meter. The basic measurement principle is as follows: the conductivity cell comprises a pair of electrodes, known as poles, to which the instrument applies a voltage. The conductivity meter then measures the current flowing and calculates the conductivity value of the medium. Measurement of TDS (Total Dissolved Solids) and salinity Some conductivity meters can also be used to measure other parameters, such as TDS (Total Dissolved Solids) and salinity. The TDS (Total Dissolved Solids) value is used to estimate the amount of solids dissolved in a solution. It corresponds to the mass of all the cations, anions and any other undissociated species present in an aqueous solution. It is expressed in mg/l or ppm. Salinity measurement assesses salt levels, expressed in PSU (Practical Salinity Units). pH-meters and conductivity meters are used in a wide range of sectors: agri-food, water analysis and treatment, industrial processes, environmental analysis, education, research, etc. CA 10001 - CA 10002 REF.: P01710015 REF.: P01710016 Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology IP 65 pH °C °F STRENGTHS · Watertight · Simple measurement · Long pH electrode · Automatic calibration at 1, 2 or 3 points · Automatic temperature compensation (ATC ) ADDITIONAL INFO ·CA 10001: general use, quick pH checks and isolated tests ·CA 10002: specially adapted for the agri-food sector with a pH electrode with a glass tip for measurements in semi-solid, protein-rich samples such as cheese, milk, etc CA 10001 CA 10002 Measurement pH 0.00 to 14,00 pH 2.00 to 12.00 pH ranges Temperature 0.0 to 60.0 °C / 32.0 to 140.0 °F 0.0 to 80.0 °C / 32.0 to 176.0 °F pH Resolution Temperature 0.1 °C / 0.1 °F 0.01 pH 0.5 °C / 0.5 °F pH Error Temperature ± 0.1 pH ± 1 °C / ± 2 °F Calibration Automatic; 1, 2 or 3 points; buffers memorized Interchangeable electrode No Power supply/ battery life 2 x CR2032 3V batteries / >100 hours Automatic power off After 20 minutes without use Dimensions/weight 226 x 36 x 20 mm / 65 g 228 x 36 x 20 mm / 65 g Environment Warranty 0 to 50 °C (32 to 122 °F); 0 to 80 °C (32 to 176 °F); max. HR 80 % max. HR 80 % 1 year CONTENTS Instrument delivered in a cardboard box with: ·2 x CR2032 3V batteries, ·1 storage vial for the electrode, ·1 multilingual user's manual, ·1 verification certificate. ACCESSORIES / REPLACEMENT PARTS pH 4.01 buffer solution (DIN-NIST)*, 125 mL pH 7.00 buffer solution (DIN-NIST)*, 125 mL pH 10.01 buffer solution (DIN-NIST)*, 125 mL Set of 3 plastic beakers P01700106 P01700107 P01700109 P01710056 * Solution delivered with a quality certificate guaranteeing compliance with the NIST (National Institute of Standards and Technology) and DIN 19266 standards. TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3131 PHYSICAL & ENVIRONMENTAL MEASUREMENTS > pH-METER > CA 10101 °C °F CA 10101 REF.: P01710010 IP 67 pH Redox Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Ergonomic, rugged and 100% watertight · Extra-wide multi-display LCD screen · Guided, ultra-simplified pH calibration (up to 3 buffer solutions) · Immediate or programmable recordings of more than 100,000 time/date-stamped measurements · Signal stability indicator ADDITIONAL INFO · Shockproof sheath supplied as standard · USB port for data transfer onto PC · Compatible with the Data Logger Transfer module of the Dataview® software for: - configuration of the instrument - display of the data - recovery of the recorded measurements (samples and calibrations) - programming of recordings - automatic export of the reports ACCESSORIES / REPLACEMENT PARTS XRGST1 pH combination electrode with built-in temperature sensor XRPTST1 ORP combination electrode with built-in temperature sensor See all the accessories on page 136 P01710051 P01710052 SPECIFICATIONS Measurement parameters CA 10101 pH -2.00 to 16.00 pH Measurement ranges (instrument alone) Redox ±199.9 mV -1999 to -200 and +200 to +1999 mV Temperature -10.0 to +120.0°C / 14.0 to 248.0°F pH 0.01 pH Resolution (R) Redox 0.1 mV 1 mV Temperature 0.1 °C / 0.1 °F Intrinsic uncertainty of the instrument (without electrode) pH Redox Temperature ± 0.01 pH ± R ± 0.1 mV ± R ± 1 mV ± R < 0.4°C / < 0.7°F Calibration pH Redox Automatic, up to 3 points, 3 groups of predefined standard reference solutions (modifiable) Automatic, 1 point, two predefined standard reference solution values (modifiable) Temperature compensation Automatic (ATC) or manual (MTC), -10°C to +120°C (14°F to 248°F) Electrode pH Redox XRGST1 (supplied), pH combination electrode with built-in temperature sensor (Pt1000), 8-pin DIN connector and 1 m cable XRPTST1 (option), ORP combination electrode with built-in temperature sensor (Pt1000), 8-pin DIN connector and 1 m cable Data storage Date and time Storage Yes > 100,000 measurements Connectors Sensor input 8-pin DIN (adapters for BNC, S7 and Jack available as options) Communication interface Type-B micro USB (USB device) Batteries Ingress protection Number - Type Battery life Auto power-off 4 x 1.5 V AA or LR06 alkaline batteries Approximately 300 hours of continuous operation Automatic power-off after 3, 10 or 15 min without use (adjustable) IP67 Environmental conditions Storage range (excluding batteries, electrodes & buffer solutions) Operating range -20 to + 70°C -10 to +55 °C Dimensions (with sheath) 211 x 127 x 54 mm Weight (without electrode) 600 g Warranty (instrument alone) 2 years CONTENTS CA 10101 delivered in site-proof case with: ·1 x XRGST1 pH electrode with built-in temperature sensor ·4 x 1.5 V LR06 batteries ·1 protective sheath mounted on the instrument ·2 ready-to-use pH 4.01 and 7.00 buffer solutions (compliant with NIST/DIN) ·2 plastic beakers ·1 USB/USB cable ·1 wrist strap 132 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com PHYSICAL & ENVIRONMENTAL MEASUREMENTS > CONDUCTIVITY METER > CA 10141 CA 10141 REF.: P01710020 IP 67 TDS °C Conductivity Resistivity Salinity °F Diagnostics & inspection Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Parameters measured: conductivity, TDS (Total Dissolved Solids), resistivity, salinity, temperature (°C or °F) · Ergonomic, rugged and watertight · Extra-wide multi-display LCD screen · Storage of 100,000 time/date-stamped measurements · Signal stability indicator · Calibration: 1 point, 6 predefined conductivity reference standards (user-modifiable) ADDITIONAL INFO Simultaneous display of the conductivity specific to the selected reference temperature (20 or 25 °C) and the actual temperature of the sample · USB interface for easy data export onto PC · Compatible with the Data Logger Transfer module of the Dataview software ·Adjustable reference temperature, temperature correction coefficient and TDS factor ACCESSORIES / REPLACEMENT PARTS 147 S/cm conductivity standard reference solution 1408 S/cm conductivity standard reference solution See all the accessories on page 136 P01700117 P01700118 SPECIFICATIONS Conductivity Measurement ranges (instrument alone) Resolution (R) Intrinsic uncertainty (instrument alone) TDS Measurement ranges (instrument alone) Resolution (R) Intrinsic uncertainty (instrument alone) Resistivity Measurement ranges (instrument alone) Resolution (R) Intrinsic uncertainty (instrument alone) Salinity Measurement ranges (instrument alone) Resolution (R) Intrinsic uncertainty (instrument alone) Temperature Measurement ranges (instrument alone) Resolution (R) Intrinsic uncertainty (instrument alone) Available reference temperature Calibration Temperature compensation Temperature compensation mode Conductivity sensor Type Data storage Connector Date and time Storage Sensor input CA 10141 0.050 S/cm to 500.0 mS/cm 0.001 to 0.1 (depending on range) ± 0.5% ± R 0.001 mg/l to 499.9 g/l 0.001 to 0.1 (depending on range) ± 0.5% ± R 2.000 .cm to 19.99 M.cm 0.001 to 0.01 (depending on range) ± 0.5% ± R 2.0 to 42.0 psu 0.1 ± 0.5% ± R - 10 to + 120°C (14 to 248°F) 0.1 °C (0.1°F) < 0.4°C (< 0.7°F) 20/25 °C (68/77°F) 1 point, 6 predefined conductivity reference standards (user-modifiable); Possibility of returning to a default calibration Automatic (ATC) or manual (MTC), linear or non-linear XCP4ST1 (supplied), 4-pole conductivity sensor with built-in temperature sensor (Pt 1000) 8-pin DIN, 1 m cable Yes > 100,000 measurements 8-pin DIN (adapters for BNC, S7 & Jack available as options) Communication interface Type B micro-USB (USB device) 12 Mbit/s Batteries Number - Type Battery life 4 x 1.5 V AA or LR06 alkaline batteries Approx. 300 hours of continuous operation Auto power-off After 3, 10 or 15 min without use (adjustable) Environmental conditions Storage range (without batteries) Operating range Ingress protection Dimensions (with sheath) Weight (without sensor) Warranty (instrument alone) -20 to 70 °C -10 to +55 °C IP67 211 x 127 x 54 mm 600 g 2 years CONTENTS CA 10141 delivered in site-proof case with: ·1 x XCP4ST1 4-pole conductivity cell with built-in temperature sensor ·4 x 1.5 V LR06 batteries ·1 protective sheath mounted on the instrument ·1 x 1408 S/cm conductivity standard reference solution ·1 plastic beaker ·1 USB - micro USB cable ·1 wrist strap TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3133 PHYSICAL & ENVIRONMENTAL MEASUREMENTS > THERMOMETERS > K THERMOCOUPLE SENSORS THERMOMETERS K THERMOCOUPLE SENSORS Model Model SK20 Description Sheathed sensor as per the NF EN 61615 standard. Hot junction isolated from chassis-earth. Inconel 600 protective sheath Type / Application Measurement Tolerance range class Response time at 63% Plunger diameter Plunger length Ref. Model Flexible generalpurpose sensor -40 °C to 450 °C Cl. 1 1 s 1,5 mm 1 m P01655010 SK20 "General-purpose" sensor recommended SK6 for measurements where access is difficult. Do not use in liquids (tip is not watertight) Flexible sensor -50 °C to 285 °C Cl. 2 1 s by contact 1 mm 1 m P03652906 SK6 Sensor with stainless-steel sheath SK2 which can be bent as required Radius of curvature > 4 mm SK3 Slightly bendable sensor with stainless-steel sheath Bendable generalpurpose sensor -50 °C to 1000 °C Cl. 2 3 s in ambient 2 mm conditions 1 m P03652902 SK2 Semi-rigid generalpurpose -50 °C to 1000 °C Cl. 2 sensor 2 s 4 mm 50 cm P03652903 SK3 SK13 Sensor with stainless-steel sheath Generalpurpose sensor -50 °C to 1100 °C Cl. 2 6 s 3 mm 30 cm P03652918 SK13 SK7 In "calm" conditions without air movement, shake the sensor to encourage heat exchange Air sensor for ambient measurement -50 °C to 250 °C Cl. 2 12 s 5 mm 15 cm P03652907 SK7 SK17 In "calm" conditions without air movement, shake the sensor to encourage heat exchange Air sensor for ambient measurement -50 °C to 600 °C Cl. 2 5 s 6 mm 13 cm P03652921 SK17 SK1 Sensor with stainless-steel sheath for penetration (20 mm min.) in pasty, viscous or liquid specimens Needle sensor for penetration -50 °C to 800 °C Cl. 2 1 s 3 mm 15 cm P03652901 SK1 SK11 Sensor with stainless-steel sheath for penetration (20 mm min.) in pasty, viscous or liquid specimens Needle sensor for penetration 50 °C to 600 °C Cl. 2 12 s 3 mm 13 cm P03652917 SK11 Sheathed sensor with stainless-steel sensing element and Teflon base. SK4 For small flat surfaces. Contact can be improved by using silicone grease. SK14 For surface temperatures when access is difficult For flat surfaces. The spring ensures optimum contact even if the sensor SK5 is not positioned perpendicularly. Contact can be improved by using silicone grease. For flat surfaces. The spring ensures optimum contact even if the sensor SK15 is not positioned perpendicularly. Contact can be improved by using silicone grease. Surface sensor 0°C à 250°C Elbowed surface sensor -50°C to 450°C Surface sensor with spring -50°C to 500°C Surface sensor with spring -50°C to 900°C For measurements on pipes. The copper SK8 sheet is applied to the clean, dry pipe. The two-sided Velcro strip ensures contact by winding. Pipe sensor -50°C to 140°C Cl. 2 1 s 5 mm 15 cm P03652904 SK4 Cl. 2 8 s 6 mm 13 cm P03652919 SK14 5 mm Cl. 2 1 s Ø in contact 15 cm P03652905 SK5 8.5 mm Cl. 2 2 s 8 mm 13 cm P03652920 SK15 10 seconds on Cl. 2 stainless- Ø 10-90 steel pipe mm 32 cm P03652908 SK8 with 12 mm diameter SK19 Sensor with magnet for flat metal surfaces Magnetic sensor -50°C to 200°C Cl. 2 7 s 4 mm 1 m P03652922 SK19 Accuracy Class I / -40 °C to +375 °C: ± 1.5°C / +375 °C to +1000°C: ± 0.004 x T °C. Accuracy Class II / -40 °C to +333 °C: ± 2.5°C / +333 °C to +1200°C: ± 0.0075 x T °C. Standard compensated miniature male 2-pole connector. Spiral cable from 45 cm to 1m 1342 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com PHYSICAL & ENVIRONMENTAL MEASUREMENTS > ACCESSORIES / REPLACEMENT PARTS ACCESSORIES / REPLACEMENT PARTS EXTENSIONS FOR THERMOCOUPLES Models CK 1 CK 2 CK 3 CK 4 CK 1 CK 2 CK 3 Description Ø Terminated by male plug / female plug 4mm Terminated by male plug / 2 bare wires 4mm Terminated by 5-pin DIN plug / female socket 4mm Terminated by 2 banana plugs / female socket 4mm Temperature withstand of extensions: -40 °C to +100 °C CK 4 Length 1 m 1 m 1 m 1 m CK 3 CK 2 CK 1 CK 4 REFERENCES TO ORDER · CK 1 .................................................................................. P03652909 · CK 2 .................................................................................. P03652910 · CK 3................................................................................... P03652913 · CK 4................................................................................... P03652914 ACCESSORIES / REPLACEMENT PARTS · PP1 handle for CK extensions.............................................. P03652912 · Compensated miniature male 2-pole connector.................... P03652925 PT 100 TEMPERATURE SENSORS · Pt 100 temperature sensors Model Model SP 10 Type / Application Description Measurement range Surface sensor with spring For flat surfaces The spring ensures optimum contact, even if the sensor is not set up perpendicularly. Silicone grease can be used to improve contact. -50 °C to 200 °C Tolerance class Cl. B Response time at 63% 6 s Plunger diameter 5 mm SP 11 Needles sensor for penetration For penetration (20 mm minimum) in pasty, viscous or liquid media. -100 °C to 600 °C Cl. B 7 s 3 mm Plunger length Ref. 13 cm P03652712 13 cm P03652713 SP 12 Air sensor In "calm" conditions without air movement, shake the sensor to encourage heat exchange -100 °C to 600 °C Cl. B 5 s 5 mm 13 cm P03652714 SP 13 Sensor for immersion Sensor with stainless-steel sheath specially designed for liquids -100 °C to 600 °C Cl. B SP 14 Generalpurpose sensor 316L stainless-steel sensor for general use -100 °C to 450 °C Cl. A 7 s 3 mm 13 cm P03652715 7 s 3 mm 20 cm P01655020 Accuracy Class A / 0.15 °C + 0.002 x T °C Accuracy Class B / 0.3 °C + 0.005 x T °C Miniature 3-pole flat-pin connector Spiral cable from 45 cm to 1m TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3135 PHYSICAL & ENVIRONMENTAL MEASUREMENTS > ACCESSORIES / REPLACEMENT PARTS ACCESSORIES / REPLACEMENT PARTS CALIBRATORS CA 1621, CA 1623 and CA 1631 ·Mains power supply...................................... P01103057 ·Bag-MF 120 x 245 x 60 mm......................... P01298075 ·Set of 2 red/black crocodile clips.................. P01295457Z ·Set of 2 red/black moulded PVC cables......... P01295451Z ·Set of 2 x Ø 4 mm moulded test probes......... P01295458Z PH-METER CA 10101 ·pH 1.68 NIST* buffer solution, 125 ml................P01700105 ·pH 4.01 NIST* buffer solution, 125 ml................P01700106 ·pH 7.00 NIST* buffer solution, 125 ml................P01700107 ·pH 9.18 NIST* buffer solution, 125 ml................P01700108 ·pH 10.01 NIST* buffer solution, 125 ml..............P01700109 ·220 mV ORP buffer solution, 125 ml..................P01700114 ·468 mV ORP buffer solution, 125 ml..................P01700115 ·XRPTST1 ORP combination electrode with built-in temperature sensor.........................P01710052 ·XRGST1 pH combination electrode with built-in temperature sensor.........................P01710051 ·Set of 3 plastic beakers......................................P01710056 ·Shockproof sheath.............................................P01710050 ·Adapter: 8-pin DIN to BNC & Jack**...................P01295501 ·Adapter: 8-pin DIN to S7 & Jack**.....................P01295502 *Solution delivered with a quality certificate guaranteeing compliance with the NIST (National Institute of Standards and Technology) and DIN 19266 standards **Connection adapters for Chauvin Arnoux pH/redox and temperature sensors CONDUCTIVITY METER CA 10141 ·XCP4ST1 conductivity cell with built-in temperature sensor.................... P01710053 ·Conductivity standard reference solution 147 S/cm................................................... P01700117 ·Conductivity standard reference solution 1408 S/cm................................................. P01700118 ·Conductivity standard reference solution 12.85 mS/cm............................................... P01700119 ·Concentrated standard KCl solution 1mol/l...... P01700116 ·Set of 3 plastic beakers................................ P01710056 ·Conductivity adapter: 8-pin DIN to BNC & Jack.............................. P01710054 ·Conductivity adapter: 8-pin DIN to S7 & Jack................................. P01710055 ·Shockproof sheath........................................ P01710050 THERMOMETERS CA 1821, CA 1822 and CA 1823 ·Shockproof sheath + Multifix........................ P01654252 ·Multifix......................................................... P01102100Z ·Mains adapter.............................................. P01651023 ·Carrying bag................................................. P01298075 ·Metal case................................................... P01298071 ·Dataview® software...................................... P01102095 ·Bluetooth BLE modem / USB for PC.............. P01654253 ·Set of 4 x 1.5 V AA/LR6 rechargeable batteries + charger....................................... HX0053 THERMO-HYGROMETER CA 1246 ·75%RH salt cartridge................................... P01156401 ·33%RH salt cartridge................................... P01156402 ·Shockproof sheath + Multifix........................ P01654252 ·Multifix......................................................... P01102100Z ·Mains adapter.............................................. P01651023 ·Carrying bag................................................. P01298075 ·Metal case................................................... P01298071 ·Dataview® software...................................... P01102095 ·Bluetooth BLE modem / USB for PC.............. P01654253 ·set of 4 x 1.5 V AA/LR6 rechargeable batteries + charger....................................... HX0053 THERMO-ANEMOMETER CA 1227 ·Cones kit for vane flow-rate measurement (circular cross-section Ø 210mm and rectangular cross-section 346x346mm)......................... P01654250 ·Vane sensor Ø80mm.................................... P01654251 ·Shockproof sheath + Multifix........................ P01654252 ·Multifix......................................................... P01102100Z ·Mains adapter.............................................. P01651023 ·Carrying bag................................................. P01298075 ·Metal case................................................... P01298071 ·Dataview® software...................................... P01102095 ·Modem Bluetooth BLE / USB pour PC............ P01654253 ·Set of 4 x 1.5 V AA/LR6 rechargeable batteries + charger....................................... HX0053 LUXMETERS CA 1110 ·Shockproof sheath + Multifix........................ P01654252 ·Multifix......................................................... P01102100Z ·Mains adapter.............................................. P01651023 ·Carrying bag................................................. P01298075 ·Metal case................................................... P01298071 ·Dataview® software...................................... P01102095 ·Bluetooth BLE modem / USB for PC.............. P01654253 ·Set of 4 4 x 1.5 V AA/LR6 rechargeable batteries + charger....................................... HX0053 SOUND LEVEL METERS CA 832 and CA 1310 ·CA 833 sound level meter calibrator, 94 dB or 114 dB........................................... P01185301 ·Microphone extension for CA 834 (5 metres).................................................... P01102085 ·Foam wind shield.......................................... P01102083 ·Jack/USB cable for CA 834.......................... P01295478 TACHOMETERS CA 1725 and CA 1727 ·Mechanical accessories kit........................... P01174902 ·End-fittings (set of 3).................................... P01174903 ·Reflective tape (15 strips 0.1 m long)............ P01101797 ·FRB F socket................................................ P01101785 ·TACHOGRAPH software on CD-ROM............ P01174835 ·USB-A to USB-B cable.................................. P01295293 CO2 - TEMPERATURE - HUMIDITY LOGGER CA 1510 ·In-situ calibration kit..................................... P01651022 ·Hard case..................................................... P01298071 ·Desk stand................................................... P01651021 ·Wall support................................................. P01651020 ·USB mains adapter....................................... P01651023 ·USB-Bluetooth adapter................................. P01102112 ·Set of 4 x 1.5 V AA/LR6 rechargeable batteries + charger....................................... HX0053 CO DETECTOR CA 895 ·Aspiration kit with pump and extension..............P01651101 See all our accessories on page 150 For the CA 1246 · 75% RH salt cartridge.......................... P01156401 For the CA 1227 CA 1110 - CA 1821/22/23 - CA 1246 · Shockproof sheath + Multifix................ P01654252 For the CA 1227 - CA 1110 - CA 1821/22/23 CA 1246 - CA 1510 · Mains adapter...................................... P01651023 For the CA 1227 ·Cones kit for vane flow-rate measurement....................................... P01654250 For the CA 832 - CA 1310 · Sound level meter calibrator.................. P01185301 For the CA 1725 - CA 1727 · Mechanical accessories kit................... P01174902 For the CA 1510 · In-situ calibration kit............................. P01651022 For the CA 1510 · Desk stand.......................................... P01651021 For the CA 1510 · Wall-mount.......................................... P01651020 1362 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com PHYSICAL & ENVIRONMENTAL MEASUREMENTS > NOTES NOTES TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3137 ELECTRICAL SAFETY > AC CURRENT CLAMPS > SELECTION GUIDE AC CURRENT CLAMPS 139 AC/DC CURRENT CLAMPS 141 FLEXIBLE CURRENT SENSORS 142 ACCESSORIES / REPLACEMENT PARTS 143 CURRENT MEASUREMENT CHOOSING YOUR CURRENT CLAMP There is to wide range of criteria for choosing to current clamp. The approach below is designed to help define your requirements and guide you naturally towards the model which best suits your application. The criteria selected are classified from 1 to 6. To choose your clamp, we advise you to follow this logic: Measurement of direct or alternating current? > AC/DC clamps table or AC clamps table High or low currents? >see the "Input" column to define the appropriate families of clamps On small wires or large cables? >see the diagrams at the bottom of the next page and only choose families with the shapes and dimensions required What instrument will it be connected to? >see "Output / Connection" column to choose to clamp with compatible signal and connection possibilities What are your other criteria? >see "Specific features" column to check that the clamp chosen fulfils your requirements perfectly THE WIDEST RANGE OF IEC 61010-2-032 CLAMPS Our innovation, technical expertise and determination to manufacture top-quality products that comply with standards have made Chauvin Arnoux the worldwide specialist in current clamps. On the next few pages, you will find to table presenting the clamps for measuring AC/DC current, followed by to diagram giving the clamp form with dimensions and then another table grouping to large number of models for AC current. As to result of their specifications, certain clamps are specialized for specific applications: Clamps for oscilloscopes (BNC output): E27, PAC17, PAC27, MN60, Y7N, C160, D38N and MA200 C lamps for leakage currents: MN73, C173 and B102 C lamps for process currents: K1 and K2 C lamp for measurements on the secondary windings of current transformers: MN71 MINI 0x MINI 10x* MN YN C1xx DN Bxx MiniFlex® MA110 Series MiniFlex® MA130 Series MiniFlex® MA200 Series AmpFlex® A110 Series AmpFlex® A130 Series K E2X MH60 PAC 1x PAC 2x page 139 For currents Clamping Ø (mm) 10 AC DC Min MAX Output in mAa c in mVa c in mVd c in mVa c+d c Connection Insulated Ø 4 mm sockets Cable with Ø 4 mm insulated elbowed male plugs Insulated Ø 4 mm plug box with standard 19 mm spacing Coaxial cable with insulated male BNC connector 5 mA 150 A page 139 16 5 mA 200 A page 139 20 10 mA 240 A page page page page page 139 140 140 140 142 45 30 52 64 115 70 100 1 A 1 mA 100 mA 500 µA 80 mA 600 A 1200 A 3600 A 400 A 3000 A page page page page page page 142 142 142 142 141 141 45 140 70 70 250 250 3,9 8 100 380 500 mA 500 mA 80 mA 500 mA 100 µA 5 mA 3000 A 3000 A 30000 A 3000 A 4,5 A 150 A page page page 141 141 141 26 30 39 1 mA 500 mA 500 mA 140 A 600 A 1400 A Single-calibre Multi-calibre For multimeters For oscilloscopes For detecting leakage and insulation faults For measuring power, harmonics, etc. For the process and the 4-20/020 mA measurement loop Power supply Stand-alone Batteries(s) Mains adapter * for multimeters 1382 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ELECTRICAL SAFETY > AC CURRENT CLAMPS > MINI SERIES - MN SERIES - YN SERIES AC CURRENT MEASUREMENT Input Measurement range(1) Output - Connection Specific Features Very low current Low current Medium current High current Alternating current Direct current Current Voltage Cable + ø 4 mm safety plugs Female ø 4 mm sockets BNC connector (coaxial) Transformation ratio (input/output) Output protected against overvoltages Automatic DC zero Power measurement (low phase shift) Bandwidth (frequency in Hz) Typical accuracy 35mm Ø 10mm 115mm 34mm 46mm 35mm Series Model MINI 01 2 to 150 A MINI 02 50 mA to 100 A MINI 03 1 to 100 A MINI 05 5 mA to 10 A 1 to 100 A MINI 09 MINI102 1 to 150 A 0.05 A to 200 A Ø 16mm 130.4mm 18.5mm Ø 20mm 135mm 51mm 213mm 34 mm 30 x 63mm MINI103 0.1 A to 200 A MN08 MN09 MN10 MN11 MN12 MN13 MN14 MN15 MN21 MN23 MN38 0.5 to 240 A 0.5 to 240 A 0.5 to 240 A 0.5 to 240 A 0.5 to 240 A 0.5 to 240 A 0.5 to 240 A 0.5 to 240 A 0.1 to 240 A 0.1 to 240 A 0.1 to 24 A 0.5 to 240 A MN39 0.1 to 24 A 0.5 to 240 A MN60 0.1 A to 60 Ape ak 0.5 A to 600 Apeak MN71 10 mA to 12 A MN73 10 mA to 2.4 A 100 mA to 240 A MN88 MN89 0.5 to 240 A 0.5 to 240 A Y1N 4 A to 500 A Y2N 4 A to 500 A Y3N 4 A to 500 A Y4N 4 A to 500 A 0.15 Aac 0.15 Aac 0.1 Vac 10 Vac 0.1 Vac 0.2 Aac 15 Vd c (2) 0.2 Vac 0.2 Aac 0.2 Aac 0.2 Aac 0.2 Aac 2 Vac 2 Vac 0.2 Vac 0.2 Vac 0.2 Aac 2 Vac 2 Vac 2 Vac 2 Vac 2 Vac 6 Vp e ak 6 Vp e ak 1 Vac 2 Vac 2 Vac 20 Vd c (2) 20 Vd c (2) 0.5 Aac 0.5 Aac 5 Aac 0.5 Vdc(2) 1000/1 1000/1 1 A / 1 mV 1 mA / 1 mV 1 A / 1 mV 1 A / 100 mV 1000/1 1 A / 1 mV 1000/1 1000/1 1000/1 1000/1 1 A / 10 mV 1 A / 10 mV 1 A / 1 mV 1 A / 1 mV 1000/1 1 A / 10 mV 1 A / 100 mV 1 A / 10 mV 1 A / 100 mV 1 A / 10 mV 1 A / 100 mV 1 A / 10 mV 1 A / 100 mV 1 mA / 1 mV 1 A / 10 mV 1 A / 100 mV 1 A / 100 mV 1000/1 1000/1 100/1 500 A / 0,5 V 66mm Y7N 1 A to 1200 Apeak 1.2 Vpeak 1 A / 1 mV (1) The upper value corresponds to 120 % of the max. rated value.. (2) Reshaping of AC signal by diodes TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com Reference 48 Hz...500 Hz 2.5% P01105101Z 48 Hz...10 kHz 1% P01105102Z 2% P01105103Z 48 Hz...500 Hz 3% 2% P01105105Z 4% P01105109Z 48 Hz .. 10 kHz 1% P01106102 48 Hz .. 10 kHz 1.5% P01106103 1% P01120401 1% P01120402 2% P01120403 2% P01120404 1% P01120405 1% P01120406 40 Hz...10 kHz 1% P01120416 1% P01120417 2% P01120418 1.5% P01120419 1% P01120407 1% P01120408 2% 40 Hz...40 kHz P01120409 1.5% 1% P01120420 40 Hz...10 kHz 1% 2% P01120421 2% P01120410 2% P01120415 3% P01120001A 1% P01120028A 48 Hz...1 kHz 3% P01120029A 1% P01120005A 5 Hz...10 kHz 2% P01120075 3139 ELECTRICAL SAFETY > AC CURRENT CLAMPS > C SERIES - B SERIES - DN SERIES AC CURRENT MEASUREMENT Input Measurement range(1) Output - Connection Specific Features Very low current Low current Medium current High current Alternating current Direct current Current Voltage Cable + ø 4 mm safety plugs Female ø 4 mm sockets BNC connector (coaxial) Transformation ratio (Input/Output) Output protected against overvoltages Automatic DC zero Power measurement (low phase shift) Bandwidth (frequency in Hz) Typical accuracy 216mm 111mm Series Model Ø 52mm 31mm C100 C102 C103 C106 C107 C112 C113 C116 C117 C122 C148 312mm Ø 115mm max. 43mm 151mm 48mm 64 x 150mm 310mm 310mm C160 C173 B102 D30N D30CN D31N D32N D33N D34N D35N D36N D37N D38N 0.1 A to 1200 A 0.1 A to 1200 A 0.1 A to 1200 A 0.1 A to 1200 A 0.1 A to 1200 A 1 mA to 1200 A 1 mA to 1200 A 1 mA to 1200 A 1 mA to 1200 A 1 A to 1200 A 1 A to 300 A 1 A to 600 A 1 A to 1200 A 0.1 A to 30 Ap e ak 0.1 A to 300 Ape ak 1 A to 2000 Ap e a k 1 mA to 1,2 A 0,01 A to 12 A 0,1 A to 120 A 1 A to 1200 A 500 µA to 4 A 0.5 A to 400 A 1 A to 3600 A 1 A to 3600 A 1 A to 600 A 1 A to 1200 A 1 A to 1800 A 1 A to 1200 A 1 A to 2400 A 1 A to 3600 A 1 A to 3600 A 1 A to 600 A 1 A to 1200 A 1 A to 1800 A 1 A to 1200 A 1 A to 2400 A 1 A to 3600 A 1 A to 3600 A 0.1 A to 36 A 1 A to 360 A 1 A to 3600 A 1 A to 90 Ap e ak 1 A to 900 Ap e ak 1 A to 9000 Ap e ak 1 Aac 1 Aac 1 Aac 1 Vac 1 Vac 1 Aac 1 Aac 1 Vac 1 Vac 5 Aac 5 Aac 3 Vp e ak 3 Vp e ak 2 Vp e ak 1 Vac 4 Vac 0.4 Vac 1 Aac 1 Aac 1 Aac 1 Aac 5 Aac 5 Aac 5 Aac 3 Aac 3 Vac 0.9 Vp e a k 1000/1 1000/1 1000/1 1 A / 1 mV 1 A / 1 mV 1000/1 1000/1 1 A / 1 mV 1 A / 1 mV 1000/5 250/5 500/5 1000/5 10 A / 1 V 100 A / 1 V 1000 A / 1 V 1 A / 1 V 10 A / 1 V 100 A / 1 V 1000 A / 1 V 1 mA / 1 mV 1 A / 1 mV 3000/1 3000/1 500/1 1000/1 1500/1 1000/1 2000/1 3000/1 3000/5 500/5 1000/5 1500/5 1000/5 2000/5 3000/5 3000/3 30 A/3 V 300 A/3 V 3000 A/3 V 1 A / 10 mV 1 A / 1 mV 1 A / 0.1 mV (1) The upper value corresponds to 120 % of the max. rated value.. (2) Reshaping of AC signal by diodes 1402 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com Reference 0.5% P01120301 0.5% P01120302 0.5% P01120303 0.5% P01120304 0.5% P01120305 30 Hz...10 kHz 0.3% P01120314 0.3% P01120315 0.3% P01120316 0.3% P01120317 1% P01120306 2% 48 Hz...1 kHz 1% P01120307 1% 3% 10 Hz...100 kHz 2% P01120308 1% 0.7% 10 Hz...3 kHz 0.5% 0.3% P01120309 0.2% 10 Hz...1 kHz 0.5% 0.35% P01120083 0.5% P01120049A 30 Hz...5 kHz 0.5% P01120064 3% 30 Hz...1.5 kHz 1% P01120050A 0.5% 1% 30 Hz...1 kHz 0.5% P01120051A 0.5% 30 Hz...5 kHz 1% P01120052A 3% 1% P01120053A 0.5% 30 Hz...1.5 kHz 1% 0.5% P01120054A 0.5% 0.5% P01120055A 30 Hz...5 kHz 2% P01120056A 30 Hz...50 kHz 2% P01120057A ELECTRICAL SAFETY > AC/DC CURRENT CLAMPS > K SERIES- E SERIES - MH SERIES - PAC SERIES AC/DC CURRENT MEASUREMENT Input Measurement range Output - Connection Specific Features Very low current Low current Medium current High current Alternating current Direct current Current Voltage Cable + ø 4 mm safety plugs Female ø 4 mm sockets BNC connector (coaxial) Transformation ratio (Input/Output) Output protected against overvoltages Automatic DC zero Power measurement (low phase shift) Bandwidth (frequency in Hz) Typical accuracy Ø 3.9mm 111mm 15mm Series Model 1 mA to 4.5 Adc K1 1 mA to 3 A RMS 1 mA to 4.5 Ap e ak 25mm 67mm 100 µA to 450 mAdc K2 100 µA to 300 mArms 100 µA to 450 mAp e ak 5 mA to 2 Adc 5 mA to 1.5 Aac E25 50 mA to 80 Adc 50 mA to 60 Aac 231mm Ø 11.8mm 20mm Ø 26 mm 100 mA to 10 Ap e ak E27 500 mA to 100 Ap e ak 138 mm MH60 0.01 A to 140 Ap e ak 4.5 Vac 3 Vrms (2) 4.5 Vp e ak 4.5 Vac 3 Vrms (2) 4.5 Vp e ak 2 Vdc 1.5 Vac 600 mVdc 800 mVdc 1 mA / 1 mV 1 mA / 10 mV 1 A / 1 V 1 A / 10 mV 1Vp e ak 1Vp e ak 1 A / 100 mV 1 A / 10 mV Reference DC to 2 kHz 1% P01120067A DC to 1.5 kHz 1% P01120074A DC to 20 kHz 2% 4% P01120025 DC 3% to 100 kHz 4% P01120027 1.4 Vp e ak 10 mV/A DC to 1 MHz 1.5% P01120612 49mm Ø 30 mm ou 2 x Ø 24 mm 224mm 97mm Ø 39 mm ou 2 x Ø 25 mm ou 2 x (50 x 5) mm 236.5 mm 97mm PAC15 0.5 A to 400 Aac 0.5 A to 600 Adc 600 mVac/ dc PAC16 PAC17 0.5 A to 40 Aac 0.5 A to 60 Adc 0.5 A to 400 Aac 0.5 A to 600 Adc 0.5 A to 60 Ap e ak 0.5 A to 60 Adc 0.5 A to 600 Ap e ak 0.5 A to 600 Adc 600 mVac/ dc 600 mVac/ dc 600 mVp e ak 600 mVp e ak PAC25 0.5 A to 1000 Aac 0.5 A to 1400 Adc 1.4 Vac/dc PAC26 PAC27 0.5 A to 100 Aac 0.5 A to 150 Adc 0.5 A to 1000 Aac 0.5 A to 1400 Adc 0.5 A to 150 Ap e ak 0.5 A to 150 Adc 0.5 A to 1400 Ap e ak 0.5 A to 1400 Adc 1.5 Vac/dc 1.4 Vac/dc 1.5 Vp e ak 1.4 Vp e ak (2) Cable + electronic unit with Ø 4 mm safety plugs with 19 mm spacing for the K Series 1 A / 1 mV 1 A / 10 mV 1 A / 1 mV 1 A / 10 mV 1 A / 1 mV 1 A / 1 mV 1 A / 10 mV 1 A / 1 mV 1 A / 10 mV 1 A / 1 mV TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com DC to 30 kHz 2% P01120115 DC to 30 kHz 1.5% 2% P01120116 DC to 30 kHz 1.5% 2% P01120117 DC to 30 kHz 4% P01120125 DC to 30 kHz 1.5% 4% P01120126 DC to 30 kHz 1.5% 4% P01120127 3141 CURRENT MEASUREMENT > AmpFlex® & MiniFlex® FLEXIBLE AC CURRENT SENSORS > A110 - A130 - MA110 - MA130 - MA200 MA110 - MA130 REF.: P01120660 REF.: P01120661 REF.: P01120662 P01120663 600 V 4 67 CAT IV 1000 V CAT III 80 mA 3 kAAC calibres IP MA200 REF.: P01120570 REF.: P01120571 REF.: P01120572 600 V CAT IV 1000 V CAT III 1 MHz A110 - A130 REF.: P01120630 REF.: P01120631 REF.: P01120632 P01120633 1000 V 4 67 CAT IV 80 mA 30 kAAC calibres IP Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology MA110 STRENGTHS · For multimeters, loggers, oscilloscopes, etc. ·No magnetic saturation constraints: excellent linearity, low phase shift, wide dynamic range for measurement · Flexibility of the sensors for easier clamping of the conductor to be measured ·Compact instruments which are easy to position in residential or industrial electrical cabinets ·Click system for opening and closing the core even when handling with safety gloves MA130 MA200 ADDITIONAL INFO MA110 model & A110 model · Measures from 80 mA · Can be connected to the AC voltage input (mVAC / VAC) of any multimeter or measuring instrument equipped with Ø 4 mm female banana plugs · Can be powered by batteries or via a standard external power supply ·Equipped with an automatic power-off system which can be deactivated at start-up to perform long-duration measurement campaigns · Possesses 3 LEDs (green, yellow and orange) indicating, respectively, the power-supply status, status of the automatic power-off function and measurement capacity overruns MA130 three-phase model & A130 three-phase model ·C an be connected to the AC voltage inputs (mVAC / VAC) of any power analyser, logger or measuring instrument equipped with BNC plugs MA200 model ·Equipped with a BNC output and can be connected to all types of oscilloscopes · Offers wide bandwidth · Particularly suitable for viewing transient signals, control signals, the tripping current for thyristors or the output signal from an electronic power supply CONTENTS ·M A110 or A110 delivered with 2 x 1.5V LR6 alkaline batteries, 1 safety datasheet, 1 verification certificate ·M A130 or A130 delivered with 2 x 1.5V LR6 alkaline batteries, 1 safety datasheet, 1 verification certificate, 1 set of coloured rings for foolproofing/ identification of the cables, 3 female BNC/Ø 4 mm male plug adapters · MA200 delivered with 1 x 9 V battery, 1 verification certificate 142 A130 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com CURRENT MEASUREMENT > AmpFlex® & MiniFlex® FLEXIBLE AC CURRENT SENSORS > A110 - A130 - MA110 - MA130 - MA200 Input Measurement range Output - Connection Specific Features Very low current Low current Medium current High current Alternating current Direct current Current Voltage Cable + ø 4 mm safety plugs Female ø 4 mm sockets BNC connector (coaxial) Transformation ratio (Input/Output) Output protected against overvoltages Automatic DC zero Power measurement (low phase shift) Bandwidth (frequency in Hz) Typical accuracy Series Model MA110 3-30-300-3000/3 (17 cm / Ø 4.5 cm) 3 A 30 A 300 A 3000 A OFF OL P Auto Power Off On 3 A : 1000 mV / A 30 A : 100 mV / A 300 A : 10 mV / A 3000 A : 1 mV / A MA 110 AC CURRENT PROBE 600 V CAT IV 1000 V CAT III MA110 3-30-300-3000/3 (25 cm / Ø 7 cm) MA110 3-30-300-3000/3 (35 cm / Ø 10 cm) L2 L1 L3 L1 L2 L3 30 A 300 A 3000 A OFF OL P Auto Power Off On 30 A : 100 mV / A 300 A : 10 mV / A 3000 A : 1 mV / A MA 130 AC CURRENT PROBE L1 L3 L2 600 V CAT III L1 L2 L3 MA130 30-300-3000/3 (25 cm / Ø 7 cm) MA200 30-300/3 (17 cm / Ø 4.5 cm) MA200 30-300/3 (25 cm / Ø 7 cm) MA200 3000 /3 (35 cm / Ø 10 cm) A110 3-30-300-3000/3 (45 cm / Ø 14 cm) 3 A 30 A 300 A 3000 A OFF OL P Auto Power Off On 3 A : 1000 mV / A 30 A : 100 mV / A 300 A : 10 mV / A 3000 A : 1 mV / A A 110 AC CURRENT PROBE 600 V CAT IV 1000 V CAT III A110 3-30-300-3000/3 (80 cm / Ø 25 cm) A110 30-300-3000-30000/3 (120 cm / Ø 38 cm) L1 L2 L3 L1 L2 L3 30 A 300 A 3000 A OFF OL P Auto Power Off On 30 A : 100 mV / A 300 A : 10 mV / A 3000 A : 1 mV / A A 130 AC CURRENT PROBE L1 L3 L2 600 V CAT III L1 L2 L3 A130 30-300-3000/3 (80 cm / Ø 25 cm) 0.08 A...3 A 0.5 A...30 A 0.5 A...300 A 0.5 A...3000 A 0.08 A...3 A 0.5 A...30 A 0.5 A...300 A 0.5 A...3000 A 0.08 A...3 A 0.5 A...30 A 0.5 A...300 A 0.5 A...3000 A 0.5 A...30 A 0.5 A...300 A 0.5 A...3000 A 0.5 A...45 Ape ak 0.5 A...450 Apeak 0.5 A...45 Ape ak 0.5 A...450 Apeak 0.5 A...4500 Ap e ak 0.08 A...3 A 0.5 A...30 A 0.5 A...300 A 0.5 A...3000 A 0.08 A...3 A 0.5 A...30 A 0.5 A...300 A 0.5 A...3000 A 0.5 A...30 A 0.5 A...300 A 0.5 A...3000 A 0.5 A...30000 A 0.5 A...30 A 0.5 A...300 A 0.5 A...3000 A 3 Vac 3 Vac 3 Vac 3 Vac 4.5 Vp e ak 4.5 Vp e ak 4.5 Vp e ak 3 Vac 3 Vac 3 Vac 3 Vac 1 V/A 100 mV/A 10 mV/A 1 mV/A 1 V/A 100 mV/A 10 mV/A 1 mV/A 1 V/A 100 mV/A 10 mV/A 1 mV/A 100 mV/A 10 mV/A 1 mV/A 100 mV/A 10 mV/A 100 mV/A 10 mV/A 1 mV/A 1 V/A 100 mV/A 10 mV/A 1 mV/A 1 V/A 100 mV/A 10 mV/A 1 mV/A 100 mV/A 10 mV/A 1 mV/A 0,1 mV/A 100 mV/A 10 mV/A 1 mV/A 10 Hz to 10 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 10 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 10 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz Reference 1% P01120660 1% P01120661 1% P01120662 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 1% P01120663 1% + 0.3 A P01120570 5 Hz to 1 MHz 1% + 0.3 A P01120571 10 Hz to 10 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 10 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 5 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 1% + 0.3 A P01120572 1% P01120630 1% P01120631 1% P01120632 10 Hz to 20 kHz 10 Hz to 20 kHz 10 Hz to 20 kHz 1% P01120633 ACCESSORIES / REPLACEMENT PARTS FOR CURRENT SENSORS MiniFlex® MA110 / MA130 AmpFlex® A110 / A130 E25 / E27 MH60 PAC15/16/17 & PAC25/26/27 ·M ains adapter / USB-B cable............................................................ P01651023 - 110 V-240 V 50/60 Hz mains power pack, USB type A female 5V 1A - Charging and connection cable, USB type A male - USB type Micro-B male 1.80 m MH60 · Spare rechargeable battery................................................................. P01296049Z MN73 / C173 / B102 · AN1 artificial neutral box..................................................................... P01197201 E1N / E3N / E6N · Mains adapter ................................................................................... P01101965 K SERIES · Mains adapter ................................................................................... P01101966 PAC10/11/12/20/21/22 · Mains adapter ................................................................................... P01101967 AmpFlex® A100 · Mains adapter ................................................................................... P01101968 MiniFlex® MA100 · Mains adapter ................................................................................... P01102086 MiniFlex MA200 · Mains adapter ................................................................................... P01102087 See all the accessories on page 150 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3143 LABORATORY & EDUCATIONAL INSTRUMENTATION > INFO AND ADVICE INFO AND ADVICE TRAINING BENCHES TRAINING CASES 144 LABORATORY & 146 EDUCATIONAL 147 INSTRUMENTATION Electricity, electronics, physics, industrial maintenance & the environment: these are disciplines where measurement is crucial for identifying and understanding, theoretical phenomena through practical experience. We offer simple, educational equipment to help students to learn about subjects ranging from the study of electrical signals to the maintenance of electrical systems. STUDYING SIMPLE ELECTRICAL PHENOMENA In Electronics training, students discover the techniques using electrical signals to capture, transmit, process, store and view data. To help them, the electrical quantities may be generated by decade boxes or simulation cases. These quantities are measured by traditional measuring instruments such as voltmeters, ammeters, wattmeters and multimeters. These resistance, capacitance or inductance decade boxes are passive elements for insertion into test or development circuits in order to obtain the required resistance, capacitance or inductance values by combination. COMPLIANCE WITH THE IEC 61010-1 STANDARD These decade boxes comply with the IEC 61010-1 safety standard which establishes the safety rules for electrical measuring, control and laboratory instruments. This standard defines the normal environmental conditions of use: · Indoor use · A ltitude up to 2,000 m · Temperature from 5 °C to 40 °C · Maximum relative humidity of 80 % at temperatures up to 31 °C, with a linear decrease down to 50 % relative humidity at 40 °C · Fluctuations of the network supply voltage not exceeding ±10 % of the rated voltage · Normal presence of transient over voltages on the network power supply PRACTICAL APPLICATIONS ENCOURAGE SUCCESSFUL LEARNING Electrical installation cases, power and harmonics cases, microwave test benches and an infrared thermography bench, Chauvin Arnoux provides students with readyto-use educational models which are ideal for a large number of experiments. Their overall design aims to ensure simple use and measurements. Delivered with a guide containing practical exercises accompanied by the corresponding theoretical elements, these training cases enable students to boost their knowledge with practical skills likely to prove useful during their careers. Quantity Resistance R Current I Voltage V Power P Capacitance C Inductance L Unit (ohm) A (ampere) V (volt) W (watt) F (farad) H (henry) Resistor box 1442 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com LABORATORY & EDUCATIONAL INSTRUMENTATION > DECADE BOXES AND SHUNTS RESISTOR BOXES CAPACITANCE BOXES Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Rotary selection switch ·Mechanical stop preventing accidental switching from 10 to 1 ·Foolproofed male earth/ground terminal SPECIFICATIONS 1 decade 0.1 to 1 1 to 10 10 to 100 100 to 1000 1 to 10 k 10 to 100 k 100 to 1000 k 1 to 10 M BR 04 : 4 decades, 1 to 10 k BR 05 : 5 decades, 1 to 100 k BR 06 : 6 decades, 1 to 1 M BR 07 : 7 decades, 1 to 10 M References P03197521A P03197522A P03197523A P03197524A P03197525A P03197526A P03197527A P03197528A P01197401 P01197402 P01197403 P01197404 CONTENTS ·1-decade box delivered with 1 black male Ø 4 mm safety cable 25 cm long with rear connection · The BR 04/05/06/07 boxes are delivered with the user's manual only. ACCESSORIES / REPLACEMENT PARTS 1 black male Ø 4 mm safety cable 25 cm long with rear connection Black Ø 4 mm male jumper (x10) P01295056 P01101892A IEC/EN6110-1 - 150 V CAT II - Pol 2 - 50 V CAT III INDUCTANCE BOXES Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology SPECIFICATIONS BL 07 : 7 decades from 1 H to 10 H CONTENTS BL07 delivered with the user's manual only References P01197451 Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS Elements for mechanical and electrical assemblies ·Selection by rotary switch with contacts · Typical accuracy: 2% 1-decade boxes ·3 boxes with 11-position switch (including position 0) · 2 safety terminals Ø 4mm and one earth/ground terminal · Dimensions : 72x72x90 mm SPECIFICATIONS 1 decade 0.01 to 0.1 F 0.1 to 1 F 1 to 10 F References P03199613A P03199612A P03199611A CONTENTS 1-decade box delivered with: · 1 black male Ø 4 mm safety cable 25 cm long with rear connection ACCESSORIES / REPLACEMENT PARTS 1 black male Ø 4 mm safety cable 25 cm long with rear connection Black Ø 4 mm male jumper (x10) P01295056 P01101892A IEC/EN6110-1 - 150 V CAT II - Pol 2 - 50 V CAT III 100 mV SAFETY SHUNTS IN DOUBLE-INSULATED CASING Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · 4-wire measurement ·Red "current" terminals · Black "voltage" terminals SPECIFICATIONS 1 A 5 A 10 A 20 A 30 A CONTENTS Shunt delivered with user's manual only. References P01165221 P01165222 P01165223 P01165224 P01165225 IEC/EN6110-1 - 150 V CAT II - Pol 2 - 50 V CAT III TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3145 LABORATORY & EDUCATIONAL INSTRUMENTATION > THERMOGRAPHY TRAINING BENCHES | TRAINING CASES > CA 1875 | CA 6710 CA 1875 TP REF.: P01651620 GUIDE Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology CA 6710 REF.: P01145901 ELECTRICAL INSTALLATIONS Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS ·Highlighting of the various possible errors in thermography: problems linked to emissivity, spatial resolution, angle of measurement, transmission or reflection · Simple use and simple measurements ·Delivered with a booklet of practical exercises accompanied by the corresponding theoretical principles SPECIFICATIONS Emissivity of materials Positioning Reflection and transmission Spatial resolution Power supply CA 1875 The influence of emissivity on temperature measurement is demonstrated using sheets of different materials Visual demonstration of the influence on temperature measurement of camera positioning in relation to the target Visual demonstration of reflection and transmission phenomena and their influence Detection of minimum areas for temperature measurement according to the distance from the target 230 V 50 / 60Hz CONTENTS CA 1875 delivered in a bag with: · 1 mains power supply · Test sheets · 1 booklet presenting the theoretical principles and practical exercises STRENGTHS · Ideal for learning about electrical safety measurements · Simulation of measurements on electrical installations · Depressurization valve for air transport SPECIFICATIONS Standards illustrated Simulation of earthing systems Measurement simulations Fault simulations Electrical safety Dimensions Weight CA 6710 NF C 15-100, VDE 0100, IEE 16th, IEC 64-8, ÖVE EN-1, RBT MIE, NIN/NIV... TT, TN and IT Earth, resistivity, loops (earth and internal), insulation, RCD tests (30 mA / 300 mA), current / leakage current Phase / neutral or earth interruptions, neutral / earth reversal, leakage current Cat. II 230 V 490 x 395 x 195 mm 10 kg CONTENTS CA 6710 delivered with: · 1 x Schuko-type FR-DE mains power cable · 6 black safety leads 25 cm long with rear connection · 1 universal adapter for mains power sockets · 1 FR/DE adapter for mains power sockets ACCESSORIES / REPLACEMENT PARTS Set of 6 black Ø 4 male safety leads 25 cm long with rear connection 1 FR/DE adapter for mains power sockets P01295212 P01101981 1462 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com LABORATORY & EDUCATIONAL INSTRUMENTATION > TRAINING CASES > POWER & HARMONICS POWER & HARMONICS REF.: P01NC5003 Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology POWER & HARMONICS STRENGTHS · Hazard-free simulation of a network and a three-phase load · Variable currents, voltages, phase shift and THD SPECIFICATIONS Network simulations Measurement simulations Voltage Current Voltage variation* Current phase shift* Harmonic distortion on current and voltage* Phase outage Power supply Electrical safety Dimensions Weight POWER & HARMONICS SINGLE or THREE-PHASE (230 V mains power supply) U, I, W, W/h, var, , THD,... Mains ± 15 % 1, 2, 5, 10, 20 A ± 10 % + 8 % ; -10 % 30°, 45°, 60° ± 5° inductive or capacitive Network level, 15 %, 25 % and variable Yes Mains 230 V - 2 P + E socket IEC 61010 300 V Cat II pollution 2 490 x 395 x 195 mm 10 kg * on phase 1 ADDITIONAL INFO · The current sensors are not delivered with the training case. CONTENTS Case delivered with: · 1 mains power cable ACCESSORIES / REPLACEMENT PARTS Measurement leads page 150 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3147 LABORATORY & EDUCATIONAL INSTRUMENTATION > MICROWAVE TRAINING BENCHES > BDH R100 BDH R100 TP REF.: P01275101 GUIDE Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · Dedicated to teaching about 8.5 to 9.6 GHz microwaves with guided propagation · WR90/R100 waveguide equipped with a quick mounting system · Supplied with detailed course, teaching and lab work material · Various accessories for setting up a wide range of experiments GUNN ORITEL CF 204 power supply ORITEL BDH R100 training case SPECIFICATIONS Main possible experiments Study Measurements Readings BDH R100 GUNN oscillator Impedance Wavelength Frequency Standing wave ratio Quadratic law of a detector CONTENTS B DH R100 delivered in a case with: · 1 ORITEL OSG 100 GUNN diode oscillator · 1 ORITEL ISO 100 ferrite isolator · 1 ORITEL MOD 100 PIN diode modulator · 1 ORITEL ATM 100 variable attenuator · 1 ORITEL OND 100 cavity wavemeter with curve · 1 ORITEL LAF 100 measuring line · 1 ORITEL ADZ 100/3 impedance adapter · 1 ORITEL TGN 100 waveguide-to-coaxial transition element · 1 ORITEL DEN 100 coaxial detector · 1 ORITEL CHG 100 adapted load · 1 ORITEL CC 100 short-circuit plate · 3 ORITEL SUP 100 guide supports ELEMENTS FOR FREE-SPACE PROPAGATION 1 20 dB ANC 100/20 horn antenna 2 15 dB ANC 100/15 dB horn antenna 3 10 dB ANC 100/10 horn antenna 4 RRL100 passive radar responder 5 DR100 reflector disk 6 AND100 dielectric antenna 7 ASP100 patch antenna 8 ANF100 adjustable slot antenna ANF100F fixed slot antenna IANF100 iris for adjustable slot antenna ANP100 adjustable parabolic reflector 9 ANP100F fixed parabolic reflector Reference P01275326 P01275304 P01275325 P01275333 P01275334 P01275329 P01275328 P01275332 P01275331 P01275330 P01275327 P01275335 1 2 4 3 5 1482 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com 9 8 7 6 LABORATORY & EDUCATIONAL INSTRUMENTATION > MICROWAVE TRAINING BENCHES > BDH R100 ADDITIONAL COMPONENTS 1 ORITEL RD 100 displacement copy (for ORITEL LAF 100 measuring line) 2 DPH100 micrometer phase shifter 3 JTG100 rotating joint 4 CIR100 ferrite circulator 5 DEG100 parallel detector on guide 6 PEH100 E-H positioner 7 GD100/180 180 mm straight waveguide 8 COE100/H high plane E bend COE100/B low plane E bend COH100 plane H bend 9 CCM100 micrometer short-circuit 10 Calibrated attenuator 11 LAZ100 movable impedance adapter 12 KED100 dielectric kit 13 CDT100 multi-hole directional coupler ICDT100/30: 30 dB iris for multi-hole coupler 14 CAB100: 1 m coaxial cable Reference P01275302 P01275340 P01275338 P01275344 P01275345 P01275358 P01275350 P01275346 P01275347 P01275348 P01275351 P01275339 P01275352 P01275353 P01275341 P01275343 P01275357 14 13 1 2 10 12 11 9 7 8 4 6 5 3 ACCESSORIES / REPLACEMENT PARTS Reference ORITEL OSG 100 GUNN diode oscillator Voltage: 10 VDC - Power: +17 dBm P01275307 ORITEL MOD 100 PIN diode modulator Modulation depth > 50% for I = +10 mA P01275309 ORITEL OND 100 cavity wavemeter with curve Reading accuracy: 5 MHz P01275311 ORITEL LAF 100 measuring line Residual SWR: < 1.05 P01275312 ORITEL DEN 100 coaxial detector SWR: < 1.3 - Max. power: +19 dBm P01275315 ORITEL ISO 100 ferrite isolator Insulation: > 20 dB P01275308 ORITEL ATM 100 micrometer attenuator Attenuation: > 20 dB - Max. power: 1 W average P01275310 ORITEL ADZ 100/3 impedance adapter Number of transverse plates: 3 P01275313 ORITEL TGN 100 w aveg u ide to-coa xia l tra nsition ele m ent SWR: < 1.25 P01275314 ORITEL CHG 100 adapted load SWR: < 1.05 P01275316 ORITEL CGX 100/20 dB cross coupler Coupling: 20 dB - Directivity: 15 dB typ. P01275305 IRIS 100 coupling iris (for CGX100) 20 and 30 dB coupling P01275306 ORITEL ANC 100/15 dB horn antenna Gain: 15 dB Flange: UBR 100/UG 39 P01275304 ORITEL AFR 100 Compatible with UBR 100 / UG 39 flanges P01275301 ORITEL RD 100 displacement copy For ORITEL LAF 100 measuring line P01275302 * You are advised to use the GUNN CF204 power supply to power your GUNN diode oscillators. 2 4 3 1 5 ACCESSORIES / REPLACEMENT PARTS Reference 1 Manual rotating platform PTM100 P01275359 2 Set of 2 absorbent panels ABS100 P01275362 3 Antenna support SAN100 P01275360 4 Antenna support rod P01275349 5 Waveguide support SUP100 P01275318 Experiment frame P01275361 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3149 ACCESSORIES > Ø 4 MM BANANA CONNECTORS CONNECTORS PRODUCT-SPECIFIC ACCESSORIES ADAPTERS AND SENSORS 153 150 PROTECTION, STORAGE AND TRANSPORT 154 152 FUSES 156 Ø 4 MM BANANA CONNECTORS MEASUREMENT LEADS Model Description MOULDED Set of 2 red/black moulded PVC leads Insulated straight male plug Ø 4 mm Insulated straight male plug Ø 4 mm · 15 A · 1.5 m · 1000 V CAT IV P01295450Z Set of 2 red/black moulded silicone leadsP01295452Z Insulated straight male plug Ø 4 mm Insulated straight male plug Ø 4 mm · 15 A · 1.5 m · 1000 V CAT IV Set of 2 red/black moulded PVC leads Insulated straight male plug Ø 4 mm Insulated elbowed male plug Ø 4 mm · 15 A · 1.5 m · 1000 V CAT IV P01295451Z Set of 2 red/black moulded silicone leads Insulated straight male plug Ø 4 mm Insulated elbowed male plug Ø 4 mm · 15 A · 1.5 m · 1000 V CAT IV P01295453Z STANDARD Set of 2 red/black PVC leadsP01295288Z Insulated straight male plug Ø 4 mm Insulated straight male plug Ø 4 mm · 15 A · 1.5 m · 600 V CAT IV / 1000 V CAT III Set of 2 red/black PVC leadsP01295289Z Insulated straight male plug Ø 4 mm Insulated elbowed male plug Ø 4 mm · 15 A · 1.5 m · 600 V CAT IV / 1000 V CAT III Set of 2 red/black PVC leadsP01295290Z Insulated straight male plug Ø 4 mm with rear connection Insulated straight male plug Ø 4 mm with rear connection · 20 A · 2 m · 600 V CAT III LEADS WITH TEST PROBES Model Description FOR CAT IV & CAT III INSTALLATIONS Set of 2 red/black PVC test-probe leads Insulated straight male plug Ø 4 mm · 15 A · 1.5 m · 600 V CAT IV / 1000 V CAT III P01295455Z Set of 2 red/black PVC test-probe leads Insulated elbowed male plug Ø 4 mm · 15 A · 1.5 m · 600 V CAT IV / 1000 V CAT III P01295456Z Set of 2 IP2X PVC leads for multimeters Complies with NF C 18-510 and IEC 61010-031+A1:2008 · IP2X test probe · Insulated elbowed male plug Ø 4 mm · 15 A · 1.5 m · 600 V CAT IV / 1000 V CAT III P01295461Z 1502 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ACCESSORIES > Ø 4 MM BANANA CONNECTORS ACCESSORIES Ø 4 MM BANANA CONNECTORS LEADS WITH TEST PROBES Model Description FOR CAT II & LOWER INSTALLATIONS Measurement leads + test probes kit P01295475Z comprising: Set of 2 red/black PVC leads Insulated straight male plug Ø 4 mm Insulated elbowed male plug Ø 4 mm · 15 A · 1,5 m · 600 V CAT IV / 1000 V CAT III + Set of 2 moulded test probes Ø 4 mm · Female plug Ø 4 mm · CAT II 300 V Measurement leads + test probes kit P01295474Z comprising: Set of 2 red/black PVC leads Insulated straight male plug Ø 4 mm Insulated elbowed male plug Ø 4 mm ·15 A ·1,5 m ·600 V CAT IV / 1000 V CAT III + Set of 2 moulded test probes Ø 2 mm · Female plug Ø 4 mm ·CAT II 300 V REMOVABLE TEST PROBES Model Description FOR CAT IV & CAT III INSTALLATIONS Set of 2 red/black moulded test probes · Female plug Ø 4 mm · 15 A · CAT IV / CAT III 1000 V P01295454Z Set of 2 red / black moulded Ø 2 test probes P01295491Z · Adapted to the measurement of modular systems on DIN rail · Female plug Ø 4 mm · 10 A · CAT IV 1000 V FOR CAT II & LOWER INSTALLATIONS Set of 2 moulded test probes Ø 4 mm · Female plug Ø 4 mm · 15 A · CAT II 300 V P01295458Z Set of 2 moulded test probes Ø 2 mm · Female plug Ø 4 mm · 15 A · CAT II 300 V P01295460Z TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3151 ACCESSORIES > PRODUCT-SPECIFIC ACCESSORIES PRODUCT-SPECIFIC ACCESSORIES Model Description FOR MULTIMETERS OR TESTERS WITH + TERMINAL ON TOP Red test probe Ø 4 mm P01103060Z removable for tester or DMM Use as "hands-free" test probe · Male plug Ø 4 mm · 600 V CAT IV FOR CA 745 TESTER OR REMOTE CONTROL PROBE Red test probe Ø 4 mm P01103061Z removable with locking pin For tester or remote-control probe · Male plug Ø 4 mm · 600 V CAT IV FOR CA 745N, CA 755 AND CA 757 Set of red/black test probes P01102152Z · CAT III/IV Set of red/black test probes P01102153Z · Ø 2 mm · CAT II Set of red/black test probes P01102154Z · Ø 4 mm · CAT II FOR CA 704, CA 740 AND CA 760 VOLTAGE ABSENCE TESTERS Removable red test probe P01103059Z · Female plug Ø 4 mm · 600 V CAT IV Black test-probe lead P01295464Z Insulated elbowed female plug Ø 4 mm Length 0.85 m · 600 V CAT IV Model Description FOR ALL VOLTAGE ABSENCE TESTERS, CA 74X/XN SERIES / CA 76X/XN SERIES Set of 2 PVC IP2X leads P01295463Z for CA 760 and CA 704 VATs Complies with NF C 18-510 and IEC 61010-031+A1:2008 · IP2X test probe Ø 2 mm · Elbowed female plug Ø 4 mm · 15 A · 1,5 m · 600 V CAT IV Red removable test probe P01102008Z · Female plug Ø 4 mm · CEI 61243-3 Black test-probe lead P01102009Z Insulated elbowed female plug Ø 4 mm · Length 0.85 m · CEI 61243-3 Set of 2 IP2X leads for CA 740N and CA 760N VATs P01295462Z · IP2X test probe Ø 4 mm · Elbowed female plug Ø 4 mm · 15 A · NF C 18-510 / CEI 61243-3 1000 V · 1.5 m Also available: P01295285Z - 0.25 m lead (red) - 0.85 m lead (black) Set of IP2X accessories for VAT P01102121Z · 2 x IP2X Ø 4 mm test probes · 1 point-point cable, L = 1.10 m Model Description FOR CA 771 & CA 773 VOLTAGE ABSENCE TESTERS Set of 2 red/black IP2X test probes Ø 4 mm P01102128Z Female plug Ø 4 mm CEI 61423-3 1000 V Set of 2 red/black IP2X test probes P01102127Z Female plug Ø 4 mm 1000 V CAT IV Set of 2 red/black test probes P01102123Z Female plug Ø 4 mm 1000 V CAT IV Set of 2 red/black test probes Ø 2 mm with crystal P01102124Z Female plug Ø 4 mm CEI 61423-3 1000 V Set of 2 red/black test probes Ø 4 mm P01102125Z Female plug Ø 4 mm CEI 61423-3 1000 V Protective cap for test probe P01102126Z CA 751 measurement adapter P01101997Z · For 2P+E sockets 152 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ACCESSORIES > OTHER ACCESSORIES OTHER ACCESSORIES Model Description FOR CAT IV & CAT III INSTALLATIONS Set of 2 red/black crocodile clips P01295457Z · 15 A · 1000 V CAT IV Set of leads and measuring accessories for electricians P01295459Z · 2 x 1000 V CAT IV moulded test probes · 2 x 1.5 m 1000 V CAT IV red/black moulded leads with straight male plug elbowed male plug · 2 x red/black 1000 V CAT IV crocodile clips · 2 x 300 V CAT II moulded test probes Ø 4 mm Set of 2 red/black magnetized test probes P01103058Z For voltage measurement only Ø test probe: 6.6 mm Elbowed female plug Ø 4 mm · 1000 V CAT III / 600 V CAT IV Set of 2 red/black crocodile wire grips P01102053Z · 20 A · 1000 V CAT III Set of 2 adapters P01102101Z Insulated female BNC plugRed/black - insulated male plugs Ø 4 mm with 19 mm spacing · 600 V CAT III Set of 2 adapters HX0107 Insulated BNC male plug Insulated red/black female plugs Ø 4 mm spacing 19 mm · 600 V CAT III BNC coaxial connection cable HX0106 Insulated BNC male plug Insulated BNC male plug Impedance 50 1 m · 600 V CAT III PVC lead AG1066-Z Insulated male BNC plugInsulated straight male banana plugs Ø 4 mm (red/black) with rear connection · 1 m · 500 V CAT III Model Description FOR CAT II & LOWER INSTALLATIONS Set of 3 measurement adapters for housing P01102114Z 2 red/black insulated straight male plugs Ø 4 mm · E27 screw socket · B22 bayonet socket · 2-pole mains socket (P/N) · 250 V CAT II CA 753: Measurement adapter for 2P+E socket P01191748Z · Suitable for European and Schuko sockets · Can be used for measurements on the P (Phase), N (Neutral) and PE (Earth) conductors in total safety · Guarantees mechanical and electrical contact with all test probes (Ø2, Ø4, IP2x, etc.) · Shows the presence of a P-N voltage (> 200 V) and indicates the phase position · IEC 61010 230 V CAT II Current lead equipped with a French 2P+E mains socket P03295509 · For inserting an ammeter in series in total safety · F or measuring the current with a current clamp without having to remove the outer sheath of the power supply cable Measurement lead for French and German 2P+E mains sockets P06239307 For direct measurement on a mains socket Quick implementation and reliable connections Set of 2 red/black insulation-piercing clips P01102055Z · 30 V AC, 60 V DC CMS clamp HX0064 Copper-gold-plated beryllium contacts Output via male plugs Ø 4 mm · 1.2 m · SELV Set of 2 adapters P01101846 Red/black insulated male BNC female sockets Ø 4 mm with 19 mm spacing · 500 V CAT I, 150 V CAT III Set of 2 adapters P01101847 Red/black insulated BNC male male sockets Ø 4 mm with 19 mm spacing · 500 V CAT I, 150 V CAT III SHT40KV high-voltage probe for multimeters P01102097 Maximum rated voltage: 40 kVdc, 28 kVrms or 40 kVpeak (50/60 Hz) Input/output ratio: 1 kV / 1 V For multimeters with 10 M input impedance · CAT I Model Description EXTERNAL POWER SUPPLY & MAINS POWER PACK Set of 4 x 1.5 V LR06 rechargeable batteries with low self-discharge and charger HX0053 Set of 4 x 1.5 V LR06 rechargeable batteries with low self-discharge HX0051B 230 V / USB B mains adapter P01651023 · 110 240 V 50/60 Hz · Female USB type A, 5 V 1 A Charging and connection cable · Male USB type A Male USB type -B · 1.8 m ADAPTERS FOR TEMPERATURE MEASUREMENT SENSORS Set of 2 safety thermocouple adapters for multimeters P01102106Z Female thermocouple plug insulated red/black male plugs Ø 4 mm with 19 mm spacing Safety adapter and K-sensor temperature probe P01102107Z For multimeters and multimeter clamps equipped with a temperature measurement calibre with 19 mm-spaced banana inputs - Measurement range from -50 °C to +350 °C - Sensor length: approx. 100 cm Pt100/Pt1000 sensor adapter for multimeters HX0091 Female Pt100/Pt1000 plug Red/black insulated male plugs Ø 4 mm TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3153 ACCESSORIES > PROTECTION, STORAGE & TRANSPORT PROTECTION, STORAGE & TRANSPORT SOFT CASES E01 E02 E03 E04 E05 E06 E07 E08 SHOULDER BAGS S01 S02 S03 S04 S05 S06 S07 S08 S09 S10 BAGS S20 S21 S22 S23 HARD CASES M01-M02-M03 M04-M05 M07 MOUNTING SUPPORT WATERPROOF SITE CASES B01 F01 B02 STORAGE ACCESSORY STORAGE ACCESSORY REELING BOX.............. REF.: P01102149 To make sure that your cables are never tangled. Can be used to store up to 3 m of cable (1 x 3 m / 2 x 1.5 m). Built-in magnet for easy mounting on any metal surface. Photo L x H x P Reference Additional information SOFT CASES E01 110 x 220 x 45mm P01298065Z E02 125 x 210 x 120mm P01298049 Specific to one instrument or product range. See page 155 E03 125 x 265 x 60mm P01298043Z E04 180 x 75 x 45mm P01298012 E06 190 x 250 x 60mm P01298055 E07 250 x 190 x 80mm P01298051 E08 70 x 185 x 30mm P01298007 SHOULDER BAGS S01 120 x 200 x 60mm P01298074 Compatible with MultiFix S02 120 x 245 x 60mm P01298075 Compatible with MultiFix S03 120 x 320 x 60mm P01298076 Compatible with MultiFix S04 150 x 230 x (40+40) mm P01298032 S05 165 x 250 x 60mm P06239502 S06 180 x 220 x 75mm P01298036 S07 225 x 270 x 70mm P01298033 S08 240 x 140 x 130mm P01298006 S09 355 x 255 x 235mm P01298056 S10 360 x 200 x 140 + 360 x 160 x 35mm P01298061A BAGS S20 330 x 240 x 240mm P01298078 S21 380 x 280 x 200mm P01298066 All-terrain waterproof bottom. 2 compartments and space for documents. Supplied with shoulder strap S22 575 x 320 x 200 mm P01298067 S23 475 x 180 x 250 mm P01298031 HARD CASES M01 270 x 195 x 65mm P01298071 Equipped with foam inserts. Delivered with strap and keys M02 285 x 210 x 80mm P01298037 Specific to one instrument or product range. See page 155 M03 285 x 210 x 80mm P01298037A Specific to one instrument or product range. See page 155 M04 320 x 255 x 75mm P01298004 Equipped with foam inserts. Delivered with strap and keys M05 320 x 255 x 75mm P01298011 Specific to one instrument or product range. See page 155 M07 440 x 310 x 135mm P01298072 Equipped with foam inserts. Delivered with strap and keys WATERPROOF SITE CASES B01 272 x 248 x 130mm P01298068 Equipped with foam inserts B02 272 x 248 x 182mm P01298069 Equipped with foam inserts MULTIFIX MOUNTING ACCESSORY......RÉF.: P01102100Z When used with the compatible soft cases and bags, this helps you to transport and mount the measuring instruments for greater user comfort.. 1542 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ACCESSORIES > PROTECTION, STORAGE & TRANSPORT CHOOSE THE RIGHT PROTECTION FOR YOUR INSTRUMENT Photo no. Mounting acc. Reference AL834 AN1 artificial neutral box CA 1052 CA 1310 CA 1621, CA 1623, CA 1631 CA 1725, CA 1727 CA 1860, CA 1862, CA 1864 and CA 1866 CA 1877, CA 1878, CA 1882 CA 40 CA 401, CA 402, CA 403, CA 404, CA 405, CA 406, CA 406 KIT CA 41, CA 43 CA 5001, CA 5003, CA 5005 CA 5005 CA 5011 CA 5030 CA 5110, CA 5120 CA 5205G/10G/20G/30G/40G/60G CA 5231, CA 5233 CA 5271/73/75/77, CA 5292/93 CA 5287, CA 5289 CA 6030 CA 61, CA 65 CA 6113, CA 6116, CA 6116N, CA 6117 CA 6115N CA 6121 CA 6131, CA 6133, CA 6422, CA 6424 CA 6160 CA 6240, CA 6250, CA 6255 CA 6410, CA 6411, CA 6412, CA 6413, CA 6415 CA 6416, CA 6417 CA 6421, CA 6423 CA 6425 CA 6454, CA 6456 CA 6460, CA 6462 CA 6501, CA 6503 CA 6505 CA 6511, CA 6513 CA 6521, CA 6523, CA 6525 CA 6522/24/26, CA 6532/34/36, CA 6528 CA 6531, CA 6533 CA 6541, CA 6543 CA 6545, CA 6547 CA 6550, CA 6555 CA 702, CA 703 CA 704 CA 730, CA 735 CA 745 CA 740, CA 760, CA 740N, CA 740N IP2X, CA 760N, CA 760N IP2X CA 742, CA 742 IP2X, CA 762, CA 762 IP2X CA 745N, CA 755, CA 757 CA 771, CA 771 IP2X, CA 773, CA 773 IP2X CA 8220, CA 8230 CA 8331, CA 8333, CA 8335, CA 8336 CA 871, CA 879 CADI 2 CDA 104 DTR 8510 F01, F03, F05, F07, F09 F11N, F13N, F15 F201, F203, F205 F21 F3N F401, F403, F405, F407 F601, F603, F605, F607 F62, F65 L411, L412, L461 L452 MA400D, MA4000D MAN'X 015, MAN'X 02S MAN'X TOP, MAN'X TOP PLUS MAX 2000, MAX 3000 PAC15, PAC16, PAC17 PAC25, PAC26, PAC27 PEL102, PEL103, PEL104 PEL106 RW501, RW511, RW521, RW5012 TK 1000 TP 850 P01102100Z F01 P01298065Z E01 P01298049 E02 P01298043Z E03 P01298012 P01298012Z E04 Soft case P01298046 E05 P01298055 E06 P01298051 E07 P01298007 E08 P01298074 S01 P01298075 S02 P01298076 S03 P01298032 S04 P06239502 S05 P01298036 S06 P01298033 S07 P01298006 S08 P01298056 S09 P01298015 Shoulder bag Bag Sheath Shockproof sheath Hard case TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com P01298009B P01298016 P03298504 P01298037 M02 P01298037A M03 P01298004 M04 P01298011 M05 P01298040 M06 P01298080 M02 P01298072 M07 P01298078 S20 P01298066 S21 P01298067 S22 P01298031 S23 P01298057 P01298005 HX0302 Bag Strap 3155 ACCESSORIES > FUSES FUSES Product CA 10 CA 1621 CA 1631 CA 4010 CA 4010 CA 4020 CA 4020 CA 403 CA 404 CA 405 CA 5001 CA 5001 CA 5003 CA 5003 CA 5005 CA 5005 CA 5011 CA 5011 CA 5210 CA 5210 CA 5210G CA 5210G CA 5220 CA 5220 CA 5220G CA 5220G CA 5230G CA 5230G CA 5233 CA 5240G CA 5240G CA 5260G CA 5271 CA 5273 CA 5275 CA 5275 CA 5277 CA 5277 CA 5287 CA 5287 CA 5289 CA 5289 CA 5292 CA 6114 / 15N CA 6115N CA 6115N CA 6121 CA 6121 CA 6121 CA 6240 CA 6250 Standardized dimensions (mm) 6 x 32 5 x 20 5 x 20 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 10 x 38 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 10 x 38 6 x 32 10 x 38 6 x 32 10 x 38 6 x 32 10 x 38 6 x 32 10 x 38 6 x 32 6 x 32 10 x 38 6 x 32 6 x 32 10 x 38 10 x 38 10 x 38 6 x 32 10 x 38 6 x 32 10 x 38 10 x 38 10 x 38 10 x 38 10X38 6 x 32 5 x 20 6 x 32 5 x 20 5 x 20 6 x 32 6 x 32 5 x 20 Amperage 8 A 0.125 A 0.125 A 0.315 A 16 A 0.315 A 16 A 0.315 A 1.25 A 6.3 A 5 A 0.5 A 16 A 1.6 A 1 A 10 A 1 A 10 A 12 A 0.4 A 12 A 0,4 A 12 A 0.4 A 12 A 0.4 A 12 A 0.5 A 10A 12 A 0.5 A 0.1 A 10 A 10 A 10 A 0.63 A 10 A 0.63 A 11 A 0.44 A 11 A 0.44 A 11A 3.15 A 2 A 3.15 A 1 A 4 A 0.2 A 12.5 A 2 A Reference P01297013 P01297099 P01297099 P03297509 P03297505 P03297509 P03297505 P03297509 P01297015 P01297016 P01297035 P01297028 P01297037 P01297036 P01297039 P01297038 P01297039 P01297038 P01297021 P01297020 P01297021 P01297020 P01297021 P01297020 P01297021 P01297020 P01297021 P01297028 AT0070 P01297021 P01297028 P01297012 P01297096 P01297096 P01297096 P01297098 P01297096 P01297098 P01297092 P01297094 P01297092 P01297094 P01297092 P01297080 P01297026 P01297080 P01297031 P01297032 P01297033 P01297091 P01297090 Product CA 6250 CA 6421 CA 6423 CA 6425 CA 6460 CA 6462 CA 6470 CA 6471 CA 6472 CA 6501 CA 6503 CA 6511 CA 65113 CA 6521 CA 6522 CA 6523 CA 6524 CA 6525 CA 6526 CA 6528 CA 6531 CA 6532 CA 6534 CA 6536 CA 6541 CA 6541 CA 6543 CA 6543 CA 6545 CA 6547 CA 6549 CA5293 CdA 778N CdA 778N CdA100-A DETEC 220 IMEG 500 IMEG 500N LOCAT 110 LOCAT 220 MANIP W1 MAN'X 500 MAN'X 500 MAN'X 520A MAN'X 520A MAN'X TOP MAN'X TOP MAN'X TOP PLUS MAN'X TOP PLUS Tellurohm CA 2 Standardized dimensions (mm) 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 5 x 20 5 x 20 5 x 20 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 8 x 50 6 x 32 8 x 50 5 x 20 5 x 20 5 x 20 10 x 38 6 x 32 6 x 32 6 x 32 5 x 20 5 x 20 5 x 20 5 x 20 5 x 20 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 Amperage 16 A 0.1 A 0.1 A 0.1 A 0.1 A 0.1 A 0.63 A 0.63 A 0.63 A 0.2 A 0.2 A 1.6 A 1.6 A 0.63 A 0.63 A 0.63 A 0.63 A 0.63 A 0.63 A 0.200 A 0.63 A 0.63 A 0.63 A 0.63 A 0.1 A 2.5 A 0.1 A 2.5 A 0.1 A 0.1 A 0.1 A 11A 2 A 10 A 0.4 A 0.315 A 0.2 A 0.2 A 0.1 A 0.1 A 1.25 A 2 A 16 A 0.315 A 16 A 0.315 A 16 A 0.315 A 16 A 0.1 A Reference P01297089 P01297012 P01297012 P01297012 P01297012 P01297012 AT0094 AT0094 AT0094 P01297095 P01297095 P01297022 P01297022 P01297078 P01297078 P01297078 P01297078 P01297078 P01297078 P01297104 P01297078 P01297078 P01297078 P01297078 P01297072 P01297071 P01297072 P01297071 P03297514 P03297514 P03297514 P01297092 P03297513 P03297502 P01297020 P01297014 P02297302 P02297302 P03297514 P03297514 P01297015 P03297513 P03297505 P03297509 P03297505 P03297509 P03297505 P03297509 P03297505 P01297012 1562 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ACCESSORIES > NOTES NOTES TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3157 ABOUT METRIX > INTRODUCTION PORTABLE DIGITAL OSCILLOSCOPES 187 ANALOGUE TESTERS 1 MULTIMETERS 160 SPECTRUM ANALYSER 198 ON-SITE MULTIMETERS 164 GENERATORS 200 DIGITAL MULTIMETERS 170 POWER SUPPLIES 206 POCKET CLAMP MULTIMETERS 174 MULTIFUNCTION CALIBRATORS 208 ON-SITE ELECTRICAL SAFETY TESTER 178 TRAINING CASES AND SHUNTS 210 BENCHTOP OSCILLOSCOPES 181 ACCESSORIES FOR OSCILLOSCOPES 211 TECHNOLOGICAL BREAKTHROUGHS AND PATENTED DISCOVERIES A French brand known nationwide by generations of electricians and electronic engineers, Metrix® is Chauvin Arnoux's flagship brand in electronics for multimeters, oscilloscopes, power supplies and generators. The Engineering Department and R&D teams are still based on the site at Annecy-le-Vieux, but they can now take full advantage of the high-performance industrialization tools on the Group's production sites in Normandy. A little history... PRODUCTS METRIX: FROM THE LAMPMETER, THE ELECTRO-CLAMP AND OSCILLOSCOPES TO ... THE MULTIMETER 1936 saw the founding of a small company named CARTEX. This company enjoyed considerable growth during the years of economic expansion following the Second World War. Its main business was manufacturing portable "lampmeters" for checking the valves used in the radioelectricity sector, which was growing fast at the time. With the rising demand for electrical and electronic measurement equipment, CARTEX quickly became a major player in this sector, with products such as the lampmeter, testers and frequency generators. In 1946, it changed its name to "Compagnie Générale de Métrologie" (General Metrology Company) and began marketing its products under the Metrix brand. The launch of the "electro-clamp", allowing users to check voltages without disconnecting and measure high currents with one hand, and the production of oscilloscopes from 1948 onwards helped to quickly expand the company's offering. However, the products that really made the brand's reputation were the MX 460, launched in 1950, and more particularly, the MX 462 multimeter, which was so successful that it helped the company to grow very quickly 1950: launch of the MX 460... ...and the MX 400 electro-clamp ASYC IV 100-kcount colour graphical multimeter HEALTHY RIVALRY COMPANIES Based in Annecy, the company continued to expand, boosting the local economy, but Metrix's success and expertise in the measurement field quickly drew the attention of large industrial companies and, in 1964, ITT International (International Telegraph and Telephone) took over the company and incorporated it into its instrumentation division to develop analogue and digital multimeters. With the development of the instrumentation market, the spread of information technology offering new possibilities, the increasingly international competition and the changes in the technological and standardization requirements, Metrix joined the Chauvin Arnoux Group in 1997. This was followed by several years of good-natured competition between Chauvin Arnoux's teams and the Metrix R&D Department. In this catalogue, you will find all the Chauvin Arnoux Group's products under the Metrix brand. 1582 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ABOUT THE CHAUVIN ARNOUX GROUP > INTRODUCTION CHAUVIN ARNOUX IS AN INDUSTRIAL GROUP WITH A COMPREHENSIVE OFFERING FOR THE MEASUREMENT SECTOR Three French companies, Chauvin Arnoux, Pyrocontrole and CA Energy, offer expertise in portable instrumentation, thermal processes, and electrical equipment and energy efficiency solutions, respectively. 90 % of the products are designed and manufactured entirely in one of Group's six Research and Development centres. Chauvin Arnoux benefits from production sites mainly based in Normandy, France. Every year, it proposes a palette of more than 5,000 product references to meet the needs of contractors, government authorities and major customers in industry. INTEGRATED SERVICE! Alongside this extensive, comprehensive offering, 12 agencies under the Manumesure brand provide high-quality, nationwide metrology and regulatory testing services (repairs, metrological verification, pollution measurement, etc.). This expertise is also provided internationally via the ten local subsidiaries. INTERNATIONAL PRESENCE 10 subsidiaries in Europe, the USA, China and the Middle East, backed by export sales teams, support the Chauvin Arnoux Group's international development and promote its Chauvin Arnoux, Metrix, Multimetrix, CA Energy, Pyrocontrole, AEMC and AMRA brands on all five continents. ECO-DESIGN For several years now, the Group has been implementing an ecologically-responsible approach intended to reconcile protection of the environment and the economic imperatives. The Chauvin Arnoux Group's EcoConception (eco-design) label highlights the company's commitment to recycling and recovery of products from the design phase onwards. DESIGN AND PRODUCTION INHOUSE Every year, the Group invests nearly 10 % of its sales revenues in Research and Development to maintain its technological leadership and its reputation for design and constant innovation. Designed in its R&D centres in France, Austria and the USA, the Group's measuring instruments are manufactured in Chauvin Arnoux's factories. The plastic and metal mechanical parts are made in Vire while the printed circuits are etched in Villedieu. Assembly, conditioning, storage and shipment worldwide are all handled on the Reux (Pont-l'Évêque) site in Normandy. EDUCATION FROM MIDDLE SCHOOLS... TO HIGHER EDUCATION When studying Science and Technology, measurement is essential for assessing and understanding the theoretical phenomena through practical experiments. In both initial and higher education, it is important to determine the characteristics of a component or system, its behaviour in its environment and its evolution over time, using our measuring instruments. Our offering covers everything from easy-to-use instruments for initial training through to the more complex tools encountered by students when they start their working life. See examples in the magazine "Les Cahiers de l'Instrumentation" (in French) which deals with measurement in all its forms: news, practical exercises for high schools, reports, etc. INITIAL TRAINING & ELECTRONICS In middle schools, one of the first tasks for students involves measuring the electrical quantities and then viewing the waveform of a signal. Multimeters or oscilloscopes with a multimeter function are ideal for this initial familiarization and identification of the fundamental characteristics: amplitude, frequency, etc. View the case studies available on our website: https://www.chauvin-arnoux.com/fr/notes-dapplication ELECTRICAL ENGINEERING CLASSES In these classes, the subjects examined include converters, motors, generators and transformers. This training includes a large number of measurement operations characterized by the presence of significantly higher voltages and currents. Understanding and mastering electrical safety are crucial themes. From Voltage Absence testing with a voltage detector through to the multimeters and clamp multimeters used for TRMS measurements (AC/ DC/ AC+DC), the measuring instruments used for recurrent measurements are equipped with functions ranging from the simplest (resistance, continuity, capacitance, etc.) to the most complex (differential and relative measurements, etc.). Professional training. As a certified training organization since 1993, CHAUVIN ARNOUX proposes specific training courses. http://www.group.chauvin-arnoux.com/en/formations The Chauvin Arnoux Group is certified ISO 9001 and ISO 14001 on all its sites. VISIT OUR WEBSITE WWW.CHAUVIN-ARNOUX.COM TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3159 SELECTION GUIDE CHOOSE YOUR TESTER OR ANALOGUE MULTIMETER TYPES QUICK SELECTION Specifications Voltage measurement Resistance measurement Capacitance measurement Diode test Continuity test Phase identification Current measurement Current measurement with clamp LF electric field measurement (V/m) LED Analogue display Digital display Power supply: battery / type Pages SMD TESTER TCX 01 VOLTAGE TESTER TX 01 ANALOGUE MULTIMETERS MX 1 FIELD TESTERS VX 0003 VX 0100 AC and DC AC and DC · · · · · · · · · · AC and DC · 2 x 1.5 V / LR44 162 · 1 x 9 V / 6F22 161 · 1 x 1.5 V / LR6 161 10 Hz - 3 kHz 10 Hz - 100 kHz · · 1 x 9 V / 6F22 162 1602 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com TEST & MEASUREMENT > LED VOLTAGE TESTER > TX 01 ON-SITE ANALOGUE MULTIMETERS > MX1 TX 01 MX1 Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology With its needle and dial display, the MX 1 is easy to read and quickly displays the measurement results. STRENGTHS · IP65 shockproof and leakproof casing · Audible continuity · Protection of the ohmmeter function by an audible alarm · Parallax mirror for precise measurements · Faulty fuse indicator An essential tool for electrical testing and diagnostics. STRENGTHS · AC and DC voltage testing · Electrical continuity testing with audible and visual indication · Phase identification · Autotest function to check the status of the instrument and the battery · Extra-bright LEDs · Removable test probe with standard Ø4 mm banana connection · Built-in system for stowing the lead SPECIFICATIONS Voltage test Audible alarm Phase identification Operating frequency Diode polarity test Audible continuity Resistance Power supply Electrical safety Dimensions / weight Other TX 01 12 V to 690 V (7 diodes) U > 50 V Flashing "Ph" diode for U > 100 V DC ... 400 Hz "+" and "" Yes 2 k to 300 k (3 diodes) 1 x 9 V 6F22 600 V CAT III 193 x 47 x 36 mm / 170 g Built-in 1.2 m lead with Ø2 mm test probe + Ø2 mm removable test probe CONTENTS TX0001-Z : delivered with a removable test probe, a 9 V battery and a user's m anual SPECIFICATIONS MX1 Display Analogue with parallax mirror / Scale length 80 mm DC voltage 10 mV to 600 V Calibres 150 mV / 0.5 V / 1.5 V / 5 V / 15 V / 50 V / 150 V / 500 V / 1.5 kV(1) Accuracy class 2 AC voltage 10 mV to 600 V Calibres 5 V / 15 V / 50 V / 150 V / 500 V / 1.5 kV(1) Accuracy class 2.5 DC current 2 A to 10 A Calibres 50 A / 500 A / 5 mA / 150 mA / 500 mA / 1.5 A / 10 A Accuracy class 2 AC current 20 A to 10 A Calibres 50 A / 500 A / 5 mA / 150 mA / 500 mA / 1.5 A / 10 A Accuracy class 2.5 Resistance Audible alarm if voltage present Calibres x 1 / x 10 / x 100 Middle point 200 / 2 k / 20 k Accuracy class 2.5 Audible continuity < 150 Other measurements Diode test Yes dB Yes Ingress protection IP 65 Power supply 1 x 1.5 V AA / LR6 Electrical safety 600 V CAT III as per IEC / EN 61010-1 Edition 2 Dimensions / weight 40 x 98 x 150 mm / 420 g (1) Use limited to 600 Vmax Clamping diameter Measurement range Transformation ratio MINI 01 10 mm 2 A to 150 Aac 1,000/1 MN 09 20 mm 0.5 A to 200 Aac 1,000/1 CONTENTS MX 1 with 1 set of measurement leads with test probes, 1 x 1.5 V battery and user's manual in 5 languages. TO ORDER 1 MX 1 1 MX 1 delivered with TX1 voltage tester and a carrying case 1 MINI01 current clamp 1 MN09 current clamp ACCESSORIES See pages 211 MX1 MX0001-T P01105101Z P01120402 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3161 TEST & MEASUREMENT > SMD TESTER > TCX 01 TCX 01 FIELD TESTERS > VX0003 - VX0100 VX 0003 & VX 0100 V Hz Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology The VX 0003 and VX 0100 BioTest field testers/meters instantaneously indicate the level of the low-frequency electric field. Ideal for the residential and tertiary sectors, they can be used by both professionals and DIY enthusiasts. Measure your exposure to electromagnetic pollution in your home or office. The VX 0003 and VX 0100 testers are easy-to-use, economical and trustworthy! They are used mainly when testing new or renovated electrical installations and in technical and vocational training. Ergonomic, simple and quick for instant SMD identification. STRENGTHS · Automatic recognition of the SMD · Wide dynamic range for measurement (6,000 counts for accurate testing of the highest and lowest values) · Immediate implementation · Test probes protected by a rigid cap SPECIFICATIONS Display Range selection Resistance Capacitance Diode and semiconductor junction test Continuity test Automatic power-off Power supply Dimensions / weight 6,000 counts Automatic or Manual Range 600 6 k 60 k 600 k 6 M 60 M 6 nF 60 nF 600 nF 6 µF 60 µF 600 µF 6 mF 60 mF TX 01 Resolution 0,1 1 10 100 1 k 10 k 1 pF 10 pF 100 pF 1 nF 10 nF 100 nF 1 µF 10 µF Accuracy ±(1.2 % of reading + 2 digits) ±(5.0 % of reading + 5 digits) ±(3.0 % of reading + 3 digits) ±(5.0 % of reading + 5 digits) - 2 V Itest : ~1 mA / Vtest : ~2.8 V R < 30 10 min 2 x 1.5 V AG13 / LR44 / 357A 181 x 35 x 20 mm / 65 g STRENGTHS · Test of the pollution generated by electrical power distribution (0-3 kHz) (VX 0003/VX 0100) · Test of the pollution generated by the equipment connected (3-100 kHz) (VX 0100) · 2 complementary methods for more effective measurements - Representative method: field measurement while taking the individual's presence into account - Traditional method: fields referenced to earth · External antenna for field measurement and cable detection (VX 0100) · Audible alarm for immediate identification of the field levels · Testing in accordance with the current and future standards and directives CONTENTS VX0003 delivered in blister pack with a bag, earth cable, socket tester and 9 V battery VX0100 delivered in a hard case with a bag, earth cable, socket tester and 9 V battery ACCESSORIES Bag for VX testers HX0104 Continuity rod P01102084A CONTENTS TCX001-Z : 1 TCX delivered with soft case for storage, 2 x 1.5 V button cells and operating manual ACCESSORIES Set of 2 x 1.5 V LR44 batteries P01296036 162 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com FIELD TESTERS > LF - VX0003 VX0100 SPECIFICATIONS Display & Buzzer Display on 2 scales of 7 LEDs each 2,000-count backlit LCD display Direct display in Volt/m (compatible with standards) Buzzer proportional to E field level Indication of measurement frequency range "Low battery" & "Hold" indicators Commands On / Off (with automatic shutdown after 30 min) Measurement Hold Buzzer On/Off Measurement range selection 3 kHz filter selection (<, >, full band) Antenna & Reference Built-in "Field" antenna Removable "Field" antenna, diameter 62 mm + "cable detection" function "Individual" field measurement reference + continuity rod "Earth" field measurement reference Measurements RMS electric field intensity in V/m Sensitivity & Accuracy 2 sensitivity ranges (compatible with standards) Measurement accuracy (in laboratory conditions) Frequency range Analysis of electrical equipment 10 Hz to 3 kHz Analysis of equipment connected to the mains General specifications Power supply Mechanical specifications Warranty ACCESSORIES For VX 0100 Continuity rod Continuity rod adapter Bag For VX 0003 Hard case VX0003 VX 0100 · · · · · · · · · · · · Manual · · · Automatic · · · · · · Optional accessory · · · · 5 to 100 V/m - 100 to 2,000 V/m ±10 % on LED thresholds 1.0 to 200.0 V/m - 200 to 2,000 V/m ±3 % ± 20 D @ 50/60 Hz · 10 Hz to 3 kHz · 10 Hz to 3 kHz (3 kHz low-pass filter) 3 kHz to 100 kHz (3 kHz high-pass filter) 10 Hz to 100 kHz (no 3 kHz filter) 1 x 9 V battery (supplied) - Battery life 60 to 80 hours - Automatic power-off function (30 min) IP65 watertight casing- Dimensions 63.6 x 163 x 40 mm Weight approx. 200 g with battery 2 years P01102084A P01102034 HX0104 HX0009 THE STANDARDS · WHO / ICNIRP recommendations (World Health Organization / International Commission on Non-Ionizing Radiation Protection) · IEEE C95.6-2002 (international standard - Public, 0-3 kHz range) · European Directive 1999/519/CE (Public, 0-100 kHz range and beyond) · European Directive 2004/40/CE (Workers, 0-100 kHz range and beyond) · 2010 draft standard, EN IEC 62493 (lighting systems) · EN50366 standard and IEC 62233 in 2012 (domestic electrical equipment) TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3163 SELECTION GUIDE > ON-SITE MULTIMETERS Quick selection Technology Display resolution (counts) TRMS / AVG measurement Simultaneous display(s) Fast bargraph Graph of measurements over time Backlighting / Automatic power-off DC basic accuracy Bandwidth Auto / Manual ranges AutoPeak for Crest Factor Ingress protection Available measurements AC/DC voltage AC/DC current Single A terminal / Simultaneous U & I Resistance / audible continuity / diode test Frequency / period / duty cycle Pulse width / pulse count Capacitance Temperature Pt100-Pt1000 / J-K thermocouple dBm / resistive power U & I peak / Crest Factor Filter for digital variable speed drives Direct measurements with clamp Low impedance AC voltage measurement Measurement processing Hold / Auto-Hold display functions Min / Max / Avg monitoring Relative measurements / dB ratio / % Storage capacity + measurement graphs Time/date-stamping (SURV & MEM) RS232 / USB / Bluetooth interface Safety & reliability EN61010 CAT IV / III Electronic switch Protected access to battery/fuses "Closed casing" software calibration Catalogue page Digital for "difficult environments" Industry MTX 3290 MTX 3291 Digital 6,000 or 60,000* TRMS AC & AC+DC 2 · ·*/· 0.08 %* 20 kHz // 100 kHz* ·/· · IP67 1,000 V* or 600 V 20 A (30 s) ·/· 60 M /·/· 600 kHz /·/· ·/· 60 mF ·/·/· 250 µs /· 300 Hz Ratio V/A 300 k ·/· ·/·/·* ·/·/· Relative Surv /·/-* 600 / 1,000 * · ·/· 168-169 1642 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com SELECTION GUIDE > ON-SITE MULTIMETERS MTX 202 4,000 40 M /·/· No -/· * MTX 3291 "General-purpose" digital Electrical TRMS AC MTX 203 Digital 1 ·/0.5 % or 0.2 % 1 kHz ·/· 6,000 MTX 204 TRMS AC+DC IP54 750 V / 1,000 V 10 A - 60 M /·/· 1 kHz /·/· 100 mF -/· -/- -/- -/- - - 500 k ·/·/·/·/-/- - - / 600 - 166-167 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com "Benchtop" digital Laboratory MX 5006 MX 5060 Digital 6,000 or 60,000 TRMS AC & AC+DC 2 · ·/· 0.05 % 20 kHz to 100 kHz ·/· · 1,000 V or 600 V 20 A (30 s) ·/· 60 M /·/· 600 kHz /·/· 60 mF -/· -/· 250 µs /· 300 Hz 300 k ·/· ·/·/· ·/·/· Relative Surv /·/- 600 / 1,000 · ·/· 170 3165 BASIC ON-SITE DIGITAL MULTIMETERS MTX 202, MTX 203 & MTX 204 VA Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology A range of 2 simple, basic TRMS AC multimeters with digital display for measuring on electrical networks and installations up to 600 V CAT III. These multimeters are general-purpose professional measuring instruments. They are the best tools for day-to-day use requiring the TRMS measurements, accuracy, rugged design and reliability of an on-site instrument. STRENGTHS · Automatic TRMS AC measurements on all the calibres for most of the customary electrical signals: - AC/DC voltage; - VLowZ low-impedance voltage; - temperature in °C and °F via K thermocouple (MTX202 & MTX203); - resistance and audible continuity, diode threshold voltage test; - capacitance measurement and AC/DC current measurement from 1 A to 10A (depending on model) plus manual RANGE · No-contact voltage (NCV) indication, useful for detecting live cables at 230 V · A compact casing with a multipurpose sheath which fits in one hand: stowing of the leads, magnetized for mounting on metal cabinets and shockproof protection with the MULTIFIX system · Blue backlighting with torch for optimized display in dark environments · Automatic power-off after 30 minutes without activity which can be inhibited (permanent mode) to optimize the 500-hour battery life and the lifespan of the batteries · Easy access to the 2 x 1.5 V batteries and fuse(s) by loosening 2 screws on the rear · Compliant with the latest IEC61010-2-033 600 V CAT III safety standards · The TRMS AC/AC+DC MTX 204 measures distorted signals stably and accurately and identifies faults. The frequency and the duty cycle are measured. This model is also equipped with Min/Max and Rel functions. CONTENTS 1 multimeter with batteries and fuses installed, 1 elastomer sheath with stand (MTX204 only), 1 set of 2 safety leads, 1 wire K thermocouple (MTX202 & 203 only), user's manual. TO ORDER MTX202 delivered in blister pack MTX203 delivered in blister pack MTX204 delivered in blister pack MTX202-Z MTX203-Z MTX204-Z ACCESSORIES See pages 211 1662 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com BASIC ON-SITE DIGITAL MULTIMETERS SPECIFICATIONS Quick selection Display resolution Auto power-off Basic accuracy(Vd c ) Bandwidth Available measurements Measurement range AC/DC voltage (ranges) AC/DC current (ranges) Resistance (ranges) Audible continuity Frequency and duty cycle Diode test Capacitance (ranges) NCV Temperature Measurement processing Other measurements General specifications Power supply / Battery life Dimensions / weight Safety and reliability Electrical safety High-resistance casing Warranty MTX 202 MTX 203 MTX 204 4,000 counts 6,000 counts 30 min / Permanent mode 0.2 % 1 kHz 10mV to 750 Vac / 1,000 Vdc 400 mV to 600 V / 600 V 600 mV to 750 V / 1,000 V 20 mA to 10 A 10 µA to 10 A 1 to 40 M 1 to 60 M Yes 2 Hz to 1 kHz Yes 1 nF to 100 mF 230 V / 50 Hz -55 °C to 1,200 °C No Mode HOLD HOLD, Min/MAX, REL 2 x 1.5 V batteries / 500 h 170 x 80 x 50 mm / 320 g EN61010-02-33 - 600 V CAT III IP 54 2 years Bag: HX0052B SHT 40kV probe: P01102097 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com K thermocouple: P01102107Z 3167 DIGITAL MULTIMETERS > ASYC IV FAMILY MTX 3290 & MTX 3291 VA Hz IP67 Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology The multimeter designed for the field: a single, comprehensive, high-performance diagnostic instrument which nevertheless remains particularly easy to use! STRENGTHS · An innovative design with ergonomics suited to work in the field: fingertip function selection on the numeric keypad and comfortable grip, a large backlit LCD screen (3 positions) for viewing 2 simultaneous measurements (segments 14 mm high) · Unrivalled user-friendliness: - "Virtual" one key / one function - Automatic V/A selection by cable positions and 8 backlit function keys · Up to 2 x 60,000-count digital displays + bargraph: central zero, Vdc and Idc · 3 connection terminals, so a single fuse from 1 A to 10 A · Reminder of the measurement connections for each function · Extra-versatile: V, A, Ohms, Hz, diode, capacitance, dB, °C, etc. · Low-impedance measurement, time/date-stamped MIN, MAX and AVG monitoring, etc. · CLAMP function for direct measurement of the current by integrating the transformation ratio: 1/1, 1/10, 1/100 and 1/1,000 mV/A · Secondary measurements for electronics: DBm, resistive power, counting, pulse width, gain measurement, resistive power · Communication for MTX 3291: isolated USB; "real-time" data transfer onto PC, drivers and SCPI commands MULTIMETERS THAT GIVE YOU FINGERTIP CONTROL Unique on the market, the electronic switch replaces the traditional mechanical switch, which is the major source of faults on handheld multimeters, while also improving performance and safety. At the same time, the possibility of direct access using the keypad avoids the intermediate positions typical of mechanical switches. Each main measurement is instantaneously accessible with one of the 6 dedicated keys, without having to choose between the 4 or 5 positions of a mechanical switch for a simple voltage or current measurement. ACCESSORIES Optical/USB cable - MTX328X and MTX329X External NIMH battery charger - MTX328X and MTX329X 60,000-count MTX329X transport kit HX0056-Z HX0053 HX0052B TO ORDER DMM 6 kcts TRMS 20 kHz DMM 60 kcts TRMS 100 kHz USB MTX3290 MTX3291 CONTENTS Multimeter delivered with 4 x 1.5 V alkaline batteries, red straight/straight lead 1.5 m long, black straight/straight lead 1.5 m long, red CAT IV 1 kV test probe, black CAT IV 1 kV test probe, User's manual on CD and Quick Start Guide on paper, USB cable and remote programming manual for communicating version (MTX 3291 + SX-DMM software) 1682 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com DIGITAL MULTIMETERS > ASYC IV FAMILY SPECIFICATIONS Display Bargraph Measurement rate Ranges Resolution* DC accuracy AC and AC+DC bandwidth AC and AC+DC basic accuracy VLowZ AC DC, AC and AC+DC current Ranges Resolution* DC accuracy AC and AC+DC bandwidth AC and AC+DC accuracy Frequency Frequency ranges Resolution* Resistance and continuity Ranges Resolution* Basic accuracy Protection Audible continuity detection Diode test Voltage measurement Capacitance Ranges Resolution* Temperature with Pt100/1000 Operating range Accuracy Other functions MAX / MIN / AVG or PEAK +/REL* PWM filter* Clamp function with direct reading on V output Secondary functions* Central zero USB communication GENERAL SPECIFICATIONS Type of display PC interfaces Power supply Safety / EMC Environment Mechanical specifications Warranty (*) MTX3291 only 60 mV* 0.001 mV MTX 3291* Double, 60,000 counts 600 mV 0.01 mV 0.05 % 100 kHz 0.5 % with Central Zero for Vdc and Idc 5 measurements per second 6 V 60 V 0.0001 V 0.001 V 300 k MTX 3290 Double, 60,000 counts, TRMS 600 V 0.01 V 0.3 % 20 kHz 0.8 % 1,000 V* 0.1 V 600 µA 0.01 µA 6 mA 0.1 µA 0.08 % 20 kHz 1 % 60 mA 0.001 mA 600 mA 0.01 mA 6 A 0.1 mA 1.2 % 20 kHz 1.5 % 10 A / 20 A (30 s max) 0.1 mA 60 Hz 0.01 Hz 600 Hz 0.1 Hz 6 kHz 1 Hz 60 kHz 10 Hz 600 kHz 100 Hz 600 0.01 6 k 0.1 0.2 % 60 k 1 600 k 10 Electronic protection 600 SIGNAL < 30 +/- 5 < 5 V 6 M 100 0.5 % 60 M 1 k 3 V resolution 1 mV 6 nF 0.001 nF 60 nF 600 nF 6 µF 60 µF 600 µF 6 mF 0.01 nF 0.1 nF 0.001 µF 0.01 µF 0.1 µF 1 µF 60 mF 10 µF -200 °C to +800 °C 0.1 % On all the main measured parameters REL relative value + secondary display with measured reference value 300 Hz, 4th order low-pass filter for measurements on variable speed drives of asynchronous motors Integration of ratio: 1/1, 1/10, 1/100, 1/1,000 mV/A DBm and resistive power VA, duty cycle +/-, and pulse width Selectable or automatic for Vdc and Idc With SX-DMM SCPI commands - Transflective LCD with backlighting *, digit height 14 mm Optical USB socket SX-DMM software 4 AA batteries (or NiMH rechargeable batteries) Safety as per IEC 61010-2-033 1000 V CAT III* / 600 V CAT IV EMC as per EN61326-1 Storage -20 °C to +70 °C Operation -10 °C to +50 °C Dimensions (L x D x H): 196 x 90 x 47.1 mm / weight: 570 g 3 years TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3169 DIGITAL MULTIMETERS MX 5006 & MX 5060 VA Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology A tried and tested casing. Simple and effective. STRENGTHS · A compact, lightweight casing · A particularly easy-to-read display with widened viewing angle and digits 16 mm high · Current measurement with a single current terminal up to 10 A · MX5060: USB communication and programming with the SCPI protocol CONTENTS 1 MX: 1 mains power cable, 1 set of 2 measurement leads, 1 user's manual + USB cable and SX-DMM software for MX 5060 TO ORDER 6,000-count TRMS benchtop multimeter 60,000-count USB TRMS benchtop multimeter SPECIFICATIONS Resolution Display DC, AC and AC+DC TRMS voltage Ranges DC Useful bandwidth DC, AC and AC+DC current Ranges AC and AC+DC basic accuracy DC basic accuracy Frequency measurements Ranges Other measurements Resistance and continuity Ranges basic accuracy Audible continuity test Diode test Capacitance Temperature with K thermocouple Communication Other measurements Complementary functions IEC61010-1 safety Dimensions (H x L x D) / Masse Warranty MX5006 MX5060 LIGHTWEIGHT AND COMPACT Multidirectional handle for positioning as you wish. A casing which is can be stacked on your lab bench to save space. The mains lead can be wound round the "feet" for easy storage. A DISPLAY (890 X 450 mm) Optimized over the whole height of the casing to offer comfortable reading with 16 mm digits on the main display above a second simultaneous display. The transflective LCD screen with backlighting provides a wider viewing angle making it visible whatever the conditions. A double 60,000-count display plus an analogue view by means of a bargraph. TOP PERFORMANCE 0.05 % accuracy and AC, DC or AC+DC TRMS measurements, as required, as well as AUTO or manual ranges to optimize your measurements EXTENDED FUNCTIONS Equipped with all the traditional functions (voltage, current, resistance, continuity, diode test), these multimeters also offer extended functions: measurement of capacitance, frequency, period and REL relative. Values expressed as values and in %. Measurements in total safety for electrical engineering applications with 1,000 V CAT III protection: a VLowZ low input impedance mode for stable measurements by eliminating "stray" voltages plus a PWM filter selectable for your measurements on variable speed drives (asynchronous motors). Monitoring of your measurements with MIN / MAX (100 ms) / PEAK (1 ms) recordings to capture any faults. The 3 terminals limit handling errors with complete current autoranging from 50 to 20 A. The MX 5060 is equipped with a USB interface for remote programming and processing of the data by our SX-DMM software for multimeters. A simple, precise mechanical switch for selecting the main quantity and a secondary function key marked in colour. MX 5006 6,000 counts Transflective LCD Backlighting Widened viewing angle MX 5060 60,000 counts 600 mV to 1,000 V 0.09 % 100 kHz 60 mV to 1,000 V 0.05 % 6,000 A to 10 A (20 A / 30 s) 1 % 0.80 % 60 HZ to 60 kHz Period PWM filter 0.40 % 600 to 60 M 600 range threshold < 30 0 to 3 V 6 nF to 60 mF -200 to +1,200 °C SURV (MIN/MAX) and Peak +/- / REL HOLD and AUTO 300 Hz filter 1,000 V CAT III 295 x 270 x 95 mm / 1.85 kg 3 years 0.20 % USB 1702 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ACCESSORIES FOR MULTIMETERS SX-DMM This data acquisition software can be used to link up to 4 controllable multimeters, whether they are on-site or benchtop models. STRENGTHS List of controllable multimeters · MX26, M53, MX54, MX56, MX57, MX58, MX59 · MX554, MX556, MX5060 · MTX3250 · MTX3281, MTX3282, MTX3283 · MTX3291, MTX3292B, MTX3293B This software can be used to communicate with our multimeters via an RS232, USB or BLUETOOTH link, depending on the model: Type of measurement COMPLEMENTARY ANDROID APPLICATION FOR ASYC IV MULTIMETERS ·All the measurements on your Android mobile phone or tablet in real time. TO ORDER Software for multimeters SX-DMM2 Choosing the type of DMM Acquisition, minimum interval 0.2 s on MTX 3292B / MTX 3293B DATA DISPLAY · Graphical trace Each channel must be assigned to a COM or USB serial port for connection to be possible. Several SX-DMM sessions can be opened at the same time on a PC. The trigger mode and acquisition intervals can be set from 100 ms upwards and the clock can be managed automatically, depending on the model. · Post-acquisition processing: sorting, simple or complex Math function on the channel, zoom, addition of cursors, XY functions, addition, subtraction, multiplication and division. This software transforms your multimeter into a power monitor with up to 4 channels for your one-off tests. · The Math functions: XY, differential, integral, curve smoothing · Data export into EXCEL for processing in a spreadsheet · Screenshots COMMUNICATION ACCESSORIES MULTIMETERS MTX 3281, MTX 3282, MTX 3283, MTX 329X MX 5060 MTX 3292B, MTX 3293B MTX 3291, MX 5060 All models Description MTX 328X calibration software Optical / USB cables Bluetooth USB modem USB A-USB B cable ASYC4 100K calibration software "Open-casing" calibration software USB/RS232 adapter for PC References to order HX0059 HX0056-Z P01102112 P01295293 HX0059B P01196770 HX0055B HX0056-Z, USB cable for MTX 328X and MTX 329X Series multimeters STRENGTHS · The common software for all Metrix multimeters: SX-DMM2 · The LabView and LabWindows CVI instrument drivers and the USB drivers for our HX0055 and HX0056 accessories are available from the "Support" area on our website. ADDITIONAL INFO The remote programming guides describing the SCPI commands are delivered with the multimeters and are also available from the multimeter's Product Documentation area on our website. TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3171 ACCESSORIES FOR MULTIMETERS CALIBRATION SOFTWARE The various versions of this software help you to perform periodic testing and/or calibration of your instruments with the "casing closed" via their RS or USB serial communication interface (depending on the model), simply and effectively. Without needing to research the technical details of the instrument, users can execute "manufacturer" procedures or develop their own procedures, in compliance with the Quality monitoring standards, while ensuring in particular the reverse traceability of their processes, saving their data and printing out reports. LIST OF MULTIMETERS SUPPORTED WITH THE ASSOCIATED SOFTWARE · MTX3292B and MTX3293B HX0059B CALIBRATION KIT · MTX3291, MX5060 Calibration kit P01196770 The software can be used to generate adjustment and verification report files as well as a verification certificate. List of adjustment points with possibility of memorization, including product traceability data MTX3293 Metrology Software Step-by-step indications are provided for the connections and settings to ensure that the various adjustment phases are performed in the right order The program is useful for checking the basic measurements and the verification results are available in a file. Example: extract from the file test.txt Ranges Setting Max. dev. Meas. dev. Tolerance (%) ---------------------------------------------------------------------------------------------------------- Offset V... 0.0000 not set 100... mVdc + 90.000 not set 100... mVdc -90.000 not set 1000...mVd c + 900.00 0.7202 -0.0300 4.16 1000...mVd c - -900.00 0.7202 0.0000 0.00 Error (tolerance (%) indicates the error on the general tolerance of the MTX. Here, the adjustment error is 4.16 % of the max. tolerance. 172 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ACCESSORIES FOR MULTIMETERS CLAMPS FOR DIGITAL MULTIMETERS To measure a current > 10A, you are advised to use one of accessory clamps listed below with their measurement ranges. To avoid powering down the circuit, you are advised to measure the current with a current clamp with A or V output. The direct measurement function is implemented on the ASYC multimeters (Ax function). As the clamp function integrates a precise ratio xxxx.XA/xxxx.XV or XA, it is possible to connect a wide range of current clamps which you can find in the CHAUVIN ARNOUX Catalogue and on pages 96 to 101 of this document; however, you should check the input/output range of the clamp to ensure that it is compatible with the calibres offered by the multimeter. The accuracy of this "clamp" function depends on the accuracy of the clamp and of the calibre or range used on the multimeter. AC CURRENT GENERAL USE MINI02 MINI03 MINI05 MINI09 References P01105102Z P01105103Z P01105105Z P01105109Z Useful measurement range according to the multimeter (for use of 5 % to 100 % of the multimeter's ranges) MTX 202 1 A to 100 A 1 A to 100 A 500 mA to 100 A 1 A to 150 A MTX 203 200 mA to 100 A 1 A to 100 A 500 mA to 100 A 1 A to 150 A MTX 204 50 mA to 100 A 1 A to 100 A 5 mA to 100 A 1 A to 150 A MTX 3290 200 mA to 100 A 1 A to 100 A 5 mA to 100 A 1 A to 150 A MTX 3291 200 mA to 100 A 1 A to 100 A 5 mA to 100 A 1 A to 150 A Clamp performance features Bande passante 10 kHz 500 Hz 500 Hz 500 Hz Précision typique 1% 2% 3 % - 2 % 4% Diam. enserrage 10 mm 10 mm 10 mm 10 mm Output Connection Lead Lead Lead Lead MN08/09 P01120401/02 10 A to 240 A 1 A to 240 A 0.5 to 240 A 0.5 to 240 A 0.5 to 240 A 10 kHz 1% 20 mm Sockets/Lead MN89 P01120415 0.5 A to 240 A 0.5 A to 240 A 0.5 A to 240 A 0.5 A to 240 A 0.5 A to 240 A 10 kHz 2% 20 mm Lead C106/C107 P01120304/05 0.5 A to 1,200 A 0.5 A to 1,200 A 0.5 A to 1,200 A 0.5 A to 1,200 A 0.5 A to 1,200 A 10 kHz 0,50% 52 mm Sockets/Lead AC CURRENT GENERAL USE MINIFLEX MA110 MINIFLEX MA110 AMPFLEX A110 References P01120660 P01120661 P01120630 Useful measurement range according to the multimeter (for use of 5 % to 100 % of the multimeter's ranges) MTX 202 1 A to 3,000 A 1 A to 3,000 A 1 A to 3,000 A MTX 203 1 A to 3,000 A 1 A to 3,000 A 1 A to 3,000 A MTX 204 1 A to 3,000 A 1 A to 3,000 A 1 A to 3,000 A MTX 3290 0.08 to 3,000 A 0.08 to 3,000 A 0.08 to 3,000 A MTX 3291 0.08 to 3,000 A 0.08 to 3,000 A 0.08 to 3,000 A Clamp performance features Bandwidth 20 kHz 20 kHz 20 kHz Typical accuracy 1% 1% 1% Clamping diam. 45 mm 70 mm 140 mm Output Connection Lead Lead Lead A110 (AmpFlex®) MA110 (MiniFlex®) On the ASYC IV MULTIMETERS, the CLAMP function integrates the transformation ratio in mV or mA/A according to the coupling selected. The measurement range of clamp will be adapted to match the measurement range of the multimeter. MTX3290 and MTX3291 fixed ratios: 1/1-1/10-1/100-1/1,000 mV/A The clamps are also compatible with other multimeter models. For example : - the clamps for the MTX 3290 are compatible with the MX 5006, - the clamps for the MTX 3291 are compatible with the MX 5060. AC/DC CURRENT GENERAL USE LEAKAGE CURRENT E25 PAC16 PAC25 MN73 References P01120025 P01120116 P01120125 P01120421 Useful measurement range according to the multimeter (for use of 5 % to 100 % of the multimeter's ranges) MTX 202 100 mA to 80 A 1 A to 600 Adc 1 A to 400 Aac 1 A to 1,400 Adc 1 A to 1,000 Aac 50 mA to 240 A MTX 203 100 mA to 80 A 1 A to 600 Adc 1 A to 400 Aac 1 A to 1,400 Adc 1 A to 1,000 Aac 50 mA to 240 A MTX 204 100 mA to 80 A 1 A to 600 Adc 1 A to 400 Aac 1 A to 1,400 Adc 1 A to 1,000 Aac 50 mA to 240 A MTX 3290 5 mA to 80 A 500 mA to 600 Adc 500 mA to 400 Aac 500 mA to 1,400 Adc 500 mA to 1,000 Aac 50 mA to 240 A MTX 3291 5 mA to 80 A 500 mA to 600 Adc 500 mA to 400 Aac 500 mA to 1,400 Adc 500 mA to 1,000 Aac 50 mA to 240 A Clamp performance features Bandwidth 20 kHz 30 kHz 30 kHz 10 kHz Typical accuracy 4 % 1.5% - 3 % 1.5% - 5 % 1 % - 2 % Clamping diam. 11.8 mm 30 mm 39 mm 20 mm Output Connection Lead Lead Lead Lead PROCESS K2 P01120074A 10 mA to 450 mAdc 10 mA to 3.3 mAac 10 mA to 450 mAdc 10 mA to 3.3 mAac 10 mA to 450 mAdc 10 mA to 3.3 mAac 5 mA to 450 mAdc 5 mA to 3.3 mAac 5 mA to 450 mAdc 5 mA to 3.3 mAac 1,5 kHz 1 % 3.9 mm Casing, 19 mm spacing CURRENT TRANSFORMER MN71 P01120420 100 mA to 12 A 100 mA to 12 A 100 mA to 12 A 60 mA to 12 A 60 mA to 12 A 10 kHz 1 % 20 mm Lead TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3173 POCKET CLAMP MULTIMETERS > SELECTION GUIDE AC current DC current RMS/TRMS measurement Clamping diam. 26 mm Clamping diam. 30 mm Clamping diam. 36 mm Clamping diam. 40 mm Clamping diam. 42 mm 4,000-count display 6,000-count display 10,000-count display Backlighting Bargraph AC current DC current AC voltage DC voltage Resistance Audible continuity Diode and semi-conductor tests Frequency Temperature Hold Zero or REL Min / Max / Peak Ranges Automatic power-off 600 V CAT III 1000 V CAT III 600 V CAT IV Pages MX350 · · · · 400 A 600 V 600 V · · · · · · 175 MX355 · · · · · 400 A 400 A 600 V 600 V · · · · - / - / · · · 175 MX650 · · · · 1,000 A 750 V 1,000 A · · · · · · · / · / · · · · 176 MX655 · · · · · · 1,000 A 1,000 A 750 V 1,000 A · · · · · · · / · / · · · 176 MX670 · · · 2 · 1,000 A 1,000 A 1,400 V · · · · · · / · / · · · · 177 MX675 · · · · 2 · 1,000 A 1,400 A 1,000 A 1,400 V · · · · · · · / · / · · · · 177 1742 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com POCKET CLAMP MULTIMETERS MX 350 & MX 355 VA Hz Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology Comprehensive: all the functions needed by electricians in one hand. STRENGTHS · Compact, ergonomic clamp multimeters · Current measurement up to 400 Aac (MX 350) or 1,000 Aac and 1,000 Aac&dc (MX 355) · AC & DC voltage measurement up to 600 V · Resistance and continuity measurement · Frequency measurement (MX 350) · Automatic DC Zero (MX 355) · TRMS measurements · Peak function (1 ms) (MX 355) SPECIFICATIONS Designation Display Bargraph Clamping diam. Type of acquisition Range selection AC current Basic accuracy Bandwidth DC current Basic accuracy AC voltage Basic accuracy Bandwidth DC voltage Basic accuracy Resistance Basic accuracy Audible continuity Frequency Functions Automatic power-off Power supply Electrical safety Dimensions / weight MX350 MX355 400Aac TRMS clamp multimeter 400Aac/dc TRMS clamp multimeter 6,000 counts - 26 mm 30 mm TRMS Automatic 0.05 A to 400.0 A 1.9 % of reading + 5 D 48 to 400 Hz - 0.1 A to 400.0 A - 2.5 % of reading + 10 D 0.05 V to 600.0 V 1.9 % of reading + 5 D 48 to 400 Hz 0.03 V to 600.0 V 1 % of reading + 3 D 0.2 to 600.0 1 % of reading + 2 D 40 For I: 20 Hz to 10.00 kHz - For V: 10 Hz to 100.0 kHz - Hold Hold Zero Peak (1 ms) 20 min., deactivatable 2 x 1,5 AAA / LR03 IEC 61010-1, IEC 61010-2-032 / 600V CAT III 199 x 75 x 36 mm / 243 g (with batteries) TO ORDER 1 MX 350 clamp 1 MX 355 clamp MX0350Z MX0355Z ACCESSORIES See pages 211 CONTENTS 1 MX 35x clamp multimeter delivered with 1 set of measurement leads with test probes, 1 soft case, 2 x 1.5 V AAA alkaline batteries and 1 user's manual in 5 languages. TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3175 1,000 AMPERE CLAMP MULTIMETERS MX 650 & MX 655 VA Hz Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology Ideal for maintenance of electrical or electrotechnical machines. STRENGTHS · Clamps for measuring high current and voltages · Current measurement up to 1,000 Aac (MX 650) and 1,000 Aac and 1,000 Aac&dc (MX 655) · AC & DC voltage measurement up to 1,000 V · Resistance, continuity and frequency measurements · RMS measurements (MX 655) · Min-Max et Peak 1 ms analysis functions · Differential measurement of current, voltage and resistance SPECIFICATIONS MX650 MX655 Display 4,000 counts Bargraph 42 segments Clamping diameter 36 mm 40 mm Type of acquisition AVG RMS Range selection Automatic or manual Automatic AC current 0.05 A to 1,000 A Basic accuracy 1.9 %R + 5 D Bandwidth 50 Hz to 1 kHz DC current - 0.10 A to 1,000 A Basic accuracy - 2.5 %R + 10 D AC voltage 0.5 V to 750 V Basic accuracy 2.5 %R + 10 D Bandwidth 50 Hz to 1 kHz DC voltage 0.2 V to 1,000 V Basic accuracy 0.75 %R + 2 D 1 %R + 2 D Resistance 0.2 to 4,000 Basic accuracy 1 %R + 2 D Audible continuity 100 Diode and semi-conductor Itest 0.6 mA / Vtest junction tests 3.3 Vdc Itest 1.7 mA / Vtest 6 Vdc Frequency For current: 20 Hz to 10 kHz For voltage: 10 Hz to 10 kHz Basic accuracy 0.1 %R + 1 D Functions Hold, Peak (1 ms), Max-Min, Hold, Peak (1 ms), Max-Min, REL, Range REL Automatic power-off 30 min, deactivatable Power supply 1 x 9 V 6LF22 Electrical safety IEC 61010-1, IEC 61010-2-032, IEC 61010-2-033 - 600 V CAT III Dimensions / weight 246 x 93 x 43 mm / 400 g TO ORDER 1 MX 650 1 MX 655 MX0650-Z MX0655-Z ACCESSORIES See page 211 CONTENTS 1 MX 65x clamp multimeter delivered with 1 set of measuring leads with test probes, 1 flexible carrying bag, 1 x 9 V alkaline battery and 1 user's manual in 5 languages 1762 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com DUAL-DISPLAY TRMS CLAMP MULTIMETERS MX 670 & MX 675 VA Hz Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology Extra protection for industry and electrical power distribution. STRENGTHS · 2 simultaneous TRMS measurement channels · Dual 10,000-count backlit display · CAT IV 600 V · Voltage up to 1,400 V · Temperature measurement SPECIFICATIONS MX670 MX675 Clamping diam. 42 mm 40 mm Display 2 x 10,000 counts / backlit Type of acquisition TRMS AC/DC Range selection Automatic AC current 0.05 A to 1,000 A Basic accuracy 1.5 % of reading + 5 D Bandwidth 50 Hz to 3 kHz DC current - 0.10 A to 1 400 A Basic accuracy - 1.2 % of reading + 5 D AC voltage 0.5 V to 1,000 V Basic accuracy 1 % of reading + 5 D Bandwidth 50 Hz to 3 kHz DC voltage 0.2 V to 1,400 V Basic accuracy 1 % of reading + 2 D Resistance 0.2 to 9999 Basic accuracy 1 % of reading + 2 D Audible continuity 35 Temperature -40.0 °C to +1,200 °C / -40 °F to +2,192 °F Basic accuracy 1 % of reading + 2 °C / 1 % of reading + 4 °F Frequency Current: 0.2 Hz to 9999 Hz Voltage: 10 Hz to 9999 Hz Basic accuracy 1 % of reading + 2 counts Functions Hold Peak (1 ms) Min (500 ms) Max (500 ms) Hold Peak (1 ms) Min (500 ms) Max (500 ms) Zero Automatic power-off 10 min, deactivatable Power supply 1 x 9 V 6LF22 Electrical safety IEC 61010-1, IEC 61010-2-032, IEC 61010-2-033 600 V CAT IV / 1 000 V CAT III Dimensions / weight 272 x 80 x 43 mm / 480 g 257 x 80 x 43 mm / 440 g CONTENTS 1 MX 67x clamp multimeter delivered with 1 x 9 V alkaline battery, 1 user's manual in 5 languages, 1 soft case, 1 set of leads with Ø 4 mm test probes and K-thermocouple sensor TO ORDER 1 MX 670 1 MX 675 ACCESSORIES See pages 69 to 78 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com MX0670-Z MX0675-Z 3177 ON-SITE ELECTRICAL SAFETY TESTER MX 531 Rotating head V Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology Practical, simple measuring instrument for TT neutral systems. MX5 "3 in 1": 1- Measures the voltage and displays the connection configuration 2- Automatic earth measurement 3- 30mA trip test by pressing the TEST button STRENGTHS · A simple, reliable and accurate earth tester with a maximum resolution of 0.1 . · A 30mA RCD tester · Totally autonomous (no battery needed) with immediate display without adjustments or selection of a position · A tester suitable for any socket configuration with its rotating head and compact size · Use on 2P+E sockets with verification of the connection of the line, neutral and earth conductors. · Instantaneous display on the two-colour LCD screen facilitating interpretation of the measures according to the conformity of the installation · Measures the earth without tripping any RCDs : test current < 12 mA. · A test button to trip the 30 mAac RCD with the display held for 7 s. TO ORDER EARTH RCD30MA 1782 MX0531 SPECIFICATIONS Display Acquisition Autorange RE error / earth fault RE earth range Autorange Resolution Accuracy Protection / admissible overload RMS voltage (AC+DC) Line-neutral voltage Resolution Accuracy Indication of position RCD 30mA type AC Rated value Conditions General specifications Display Type of socket Safety Operating temperature Standards Dimensions/weight/IP/IK MX531 2,000 counts RMS AC+DC Yes Red screen displayed if RE >100 or OL>2,000 0 to 1,999 0 to 199.9 and 180 to 1,999 0.1, 1 ± (3% of reading+5D) 300V CAT III 90 to 400 V O to 420 V 50/60 Hz - Indication of L/N reversal - If <195 V and >253 V: fault 1 V ± (2%+1D) Line, neutral and earth If RE correct 230V between line and neutral, current 30mA -0%+6% Time 200ms ± 4ms Two-colour blue/red 46x50 mm backlit LCD 2P +E 10/16A -Types E and F EN61010-2-030, pollution degree 2, CATIII-300V -10 to+45°C Test as ^per IEC/EN 61557-1 -3 and -6 EMC as per IEC61236-1 IEC61010-1 CAT III 300V Dimensions 185X65X53 mm Weight: 230g ± 50g / IP40/IK07 CONTENTS MX0531 EARTH RCD30mA Equipped with a wrist-strap, bag and user's manual on paper. TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com ON-SITE ELECTRICAL SAFETY TESTERS > MX 406B / MX 604 MX 406B V MX 604 V Hz Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology Analogue insulation tester Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology Lightning arrester tester. STRENGTHS · Insulation measurement at 50, 250 and 500 Vdc · Voltage measurement up to 440 Vac/dc · Continuity (200 mA) · Quick and easy readings with the colour-scale dial · Hands-free use with remote control probe STRENGTHS · Lightning-arrester support module for measurements on unmounted lightning arresters · Probe with remotecontrol button for in-situ measurements · Measures insulation resistance at 50, 100 and 500 Vdc · Quick and easy readings with the colour-scale dial SPECIFICATIONS Insulation Continuity + audible beep Voltage Electrical safety Power supply Dimensions / weight MX406B 10 k to 200 M at 50 / 250 and 500 Vdc (3 ranges) 0 to 10 (i > 200 mAdc) 0 to 440 Vac/dc IEC 61010 300 V CAT III 3 x 1.5 V batteries for a battery life of 1,000 x 5 s measurements 155 x 98 x 40 mm / 410 g CONTENTS MX406B: 1 MX 406B tester delivered with 1 remote-control probe, 1 black safety lead, 1 black crocodile clip, 3 x 1.5 V batteries and 1 user's manual TO ORDER 1 MX 406B tester MX0406B SPECIFICATIONS SPECIFICATIONS Lightning arrester test Insulation Battery test Electrical safety Power supply Dimensions / weight MX604 0 to 600 Vdc 100 k to 2 000 M at 50 /100 and 500 Vdc (3 ranges) Yes IEC 61010 300 V CAT III 3 x 1.5 V batteries for a battery life of 1,500 x 5 s measurements 155 x 98 x 40 mm / 350 g CONTENTS 1 MX 604 delivered in a hard case with 1 detachable lightning-arrester support module, 1 remote-control probe, 1 red test probe, 1 black straight-straight lead 1.5 m long with built-in test probe, 1 black crocodile clip, 1 lightning-arrester support clamp, 1 strap mounted on the instrument, 3 batteries, 1 user's manual in 5 languages TO ORDER 1 MX 604 tester ACCESSORIES See page 211 MX0604 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3179 DIGITAL OSCILLOSCOPES INTRODUCTION The first step for choosing an oscilloscope involves taking a bit of time to think about how and where you want to use it. Here are some of the typical questions which you need to answer: · Where is the oscilloscope going to be used (in a lab, for education, in an electrical cabinet)? · How many signals do you want to measure simultaneously? 2 or 4? · What voltage ranges do you want to measure or record? · What is the maximum frequency to be measured? · Are the signals repetitive or unique? · Do you need to view the signals in the frequency domain as well as in the time domain? When these aspects have been clarified, you can start looking for the most suitable oscilloscope for your specific applications, but we are going to define the specifications to ensure the best choice. Unlike with analogue oscilloscopes, the signal to be viewed is first digitized by an ADC (analogue-digital converter). The instrument's ability to display highfrequency signals without distortion depends on the quality of this interface. Block diagram of a digital oscilloscope Y input signal Attenuator External triggering ADC Interface Data storage DAC Vertical amp. Processing Triggering Digital time base DAC Horizontal amp. The DSO (Digital Storage Oscilloscope) samples and then plots the samples as a function of time; there are 2 families of digital oscilloscopes available: - b enchtop oscilloscopes or DSOs dedicated to use in electronics: compact, large bandwidth, on-screen measurements, large storage capacity, communication and printing; - p ortable oscilloscopes dedicated to electrical use: battery life, number and type of channels, screen and analytical tools. MAIN SPECIFICATIONS TO BE TAKEN INTO ACCOUNT: · The input ranges. Our oscilloscopes offer several selectable input ranges from ± 1mV to ± 200V/div and our benchtop oscilloscopes have a common earth connection between channels and in relation to the earth, whereas our portable oscilloscopes propose channels which are isolated from one another and in relation to the earth up to 600 V. An oscilloscope with isolated channels will ensure safety and measurement flexibility in all situations, from 1 mV to 600 V. As high voltages may be measured using 10:1 and 100:1 attenuation probes or single/double differential probes, it is important to check that the oscilloscope is equipped with a sufficiently small voltage range for the signals that we want to measure. If you regularly have to measure weak signals (under 50 mV), you may have to look into buying an oscilloscope with 12-bit resolution. Check that the oscilloscope probes or accessories that you plan to use are of an equivalent or higher level or category (cf. IEC61010) than the oscilloscope's bandwidth. · Bandwidth: the first specification to consider. In fact, this is the maximum signal frequency which can pass through the input amplifiers. As a result, the analogue bandwidth of the oscilloscope must be higher than the maximum frequency that you want to measure (real time). Most oscilloscope manufacturers define the bandwidth as the frequency at which the input signal is reduced to 71 % of its real amplitude (the -3 dB point). In other words, the permitted error is 29 %. We indicate the bandwidth of our oscilloscopes at - 3 dB. · The resolution of the analogue-digital converter (vertical resolution 8/9/10/12 bits): 1/256 or 0.4 % for an 8-bit ADC, while SCOPIX (depending on models) proposes a vertical resolution of 12 bits because it is high-resolution precision oscilloscope for audio, noise and vibration applications. Dans l'électronique numérique, un changement In digital electronics, a 1% change in the signal is not usually a problem, but in audio electronics, a 0.1% distortion or noise may cause dysfunctions. Most modern DSOs are optimized to function with fast digital signals and only offer 8-bit resolution (8-bit analogue-digital converter). This means they can detect any signal change from 0.4 % upwards. · The sampling frequency ...in MS/s (mega-samples per second) or GS/s (giga-samples per second) or realtime sampling mode or ETS equivalent-time mode: According to Nyquist's theorem, the sampling rate must be equivalent to at least twice the maximum frequency that you want to measure: for Sampling Vertical quantization (8-bit ADC) 256 Trigger position Acquisition window Memory depth 103 Quantizing interval 102 Pré-déclenchement Analogue input signal 103 Trigger point Sample Calculated interpolation 1 Sampling frequency Recording duration Sampling interval (Zsam) Trigger level Time a spectrum analyser, this may be insufficient, but for an oscilloscope, you need at least 5 samples to accurately reconstitute the waveform. Most oscilloscopes have two different sampling rates (modes) depending on the signal measured: real-time mode and ETS (Equivalent Time Sample) mode, also called repetitive sampling. ETS only functions if the signal measured is stable and repetitive, since this mode operates by building a waveform from successive acquisitions. · The memory depth DSOs record samples in a buffer memory so, for a given sampling rate, the size of the buffer memory determines the maximum acquisition duration before it becomes full. The relation between the sampling rate and the memory capacity is important: an oscilloscope with a high sampling rate but a small memory capacity will only be able to use its maximum sampling rate on a few of the fastest time bases. Our SCOPIX portable oscilloscope samples at 2.5 GS/s in real time with a memory capacity of 100 kpts. The benchtop DOX3304 model offers 2 GS/s with a memory capacity of 28 Mpts. · An oscilloscope can be used to view the waveforms and signal processing tools are often useful: FFT, harmonic analysis or even recording functions which are integrated in our oscilloscopes. Furthermore, the result is increasingly displayed on a TFT LCD screen, making these instruments easy to move and significantly less energy-hungry. Our digital oscilloscopes are all equipped with a communication interface to extend the analysis (USB host or device, Ethernet or Wifi) and data processing software on PC or tablet. PC software or Android applications are available for each oscilloscope. The firmware is regularly upgraded. Keep up to date with our versions by using the firmware loader on our support website. 1802 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com BENCHTOP OSCILLOSCOPES > SELECTION GUIDE CHOOSE YOUR OSCILLOSCOPE SELECTION FAMILIES Bandwidth Channels (number/type) IEC61010 safety One-shot digital sampling ETS repetitive mode Vertical resolution Integrated modes "Oscilloscope" specifications Max. input sensitivity Max. input amplitude Analogue filters Time base (per division) Memory depth Acquisition memory No. of reference curves or math curves on screen Envelope/Averaging modes SPO (Smart Persistence Oscilloscope) Automatic measurements/cursors Pulse trigger on width/number Video trigger (line counter) Adjustable Hold-Off / Delay Calculation functions + - / x / : / Advanced Other functions Lin & Log FFT spectral analysis General specifications Colour LCD / B&W / Tube screen Communication PC software / ANDROID app. Pages CLASSIC DOX2025B DOX2070B DOX2100B 25 to 100 MHz 2 / Class 1 CAT II 300 V 500 MS/s to 1 GS/s 5 GS/s 8 bits OX 2 mV/div 10 V/div Digital filters 2.5 ns - 50 s 32 k/channel Up to 2 MB 2 -/· 32/· ·/· · ·/· 8 bits 7"/·/- 182 "ADVANCED" LAB ·/·/·/FFTUSB and Ethernet Easywave for PC ELECTRONICS EXPERT DOX3104 DOX3304 100 to 300 MHz 4 / Class 1 CAT I 300 V 1 GS/s 8 bits OX+GX+DECODE 2 mV/div 10 V/div 1 ns - 50 s/div 28 MB 4 ·/· · 32 ·/· · ·/· 8 bits 8" 184 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3181 BENCHTOP DIGITAL OSCILLOSCOPES DOX2000B FAMILY STRENGTHS · 7" panoramic colour LCD screen, resolution 800 x 480 pixels · Multiple communication interfaces · High performance and numerous functions for acquisition and analysis FFT ·REC Math 2 Mpts Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology TOP-CLASS ERGONOMICS: EXTRA-BRIGHT 7" COLOUR TFT SCREEN, RESOLUTION 800 X 480 PIXELS ·C ustomization of the display to suit your needs: normal or persistent display, YT or XY format, screen types with adjustable colours, graticule, brightness, contrast, etc. ·Simple front panel: traditional front-panel controls (rotary knobs and keys) ·5 language choices selectable per menu (English, French, Spanish, Italian, German) ·Quick power-up and power-down in less than 10 s ·E asy to transport due to its shape, its built-in handle and its 9-inch depth HIGH PERFORMANCE AND MULTIPLE FUNCTIONS FOR ACQUISITION AND ANALYSIS ·M aximum sampling rate of up to 1 GS/s in one-shot mode and 50 GS/s for periodic signals ·A cquisition memory depth from 32 kpoints to 2 Mpoints, depending on the model, to optimize your analyses ·5 complete trigger types: edge, pulse, video, slope and alternate ·32 simultaneous automatic measurements on screen and manual cursor measurements ·Recording of up to 7 Mpoints by slow acquisition Simple MATH functions +/-/*/ and "real-time" FFT function with simultaneous display of trace PRACTICAL INTERFACES AND PRINTING ·Usual communication: USB host and device (PC, USB key) ·M ultiple storage: 20 configurations and 5 types of recordings: parameters, curves, images, .csv and factory settings internally or on USB key, etc. ·Comprehensive EASYSCOPE software for all your analyses 182 Easyscope software for data processing (csv), transmission of SCPI commands, screenshots (bmp), configuration, virtual panel. TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com BENCHTOP DIGITAL OSCILLOSCOPES SPECIFICATIONS Human-machine interface Type of display Display of curves on screen Commands Choice of language Vertical deflection Bandwidth Number of channels Impedance Display of traces Maximum input voltage Vertical sensitivity Rise time Compensated probe factors Horizontal deflection Sweep speed Scan or ROLL mode Horizontal zoom Triggering Sources / Modes Roll mode Type Coupling Digital memory Maximum sampling rate Vertical resolution Memory depth File management PEAK DETECT mode (capture of transients) Display modes XY mode Other functions AUTOSET MATH functions on the channels FFT analyser Manual measurement cursors PASS / FAIL Recorder Automatic measurements Probe calibration signal Warranty DOX 2025B DOX 2070B / DOX 2100B 7" colour TFT LCD screen (resolution 800x480 px) / Brightness and contrast adjustment 8 x 16 divisions trace area / 2 curves + reference + Math function Complete graticule or borders Display mode: Samples or Vectors with interpolation or Persistence Mode Usual direct commands via buttons on front panel / System with menus on right-hand side of screen with selection using 5 buttons opposite "Menus On/Off" and print commands By menu, 5 languages (FR/EN/DE/IT/ES), online help in English 25 MHz 0 MHz / 100 MHz 20 MHz bandwidth limiter 2 channels, common chassis-earths 1 M / 18 pF and External Trig channel Channel number, earth reference indicator and trace in the colour of the channel ±300 Vp-p (without probe) 12 calibres from 2 mV to 10 V/div - Basic accuracy ±3 % < 7 ns < 5 ns (DOX 2070B) < 3.5 ns (DOX 2100B) x 0.1 / 0.2 / 1 / 5 / 10 / 50 / 100 / 500 / 1,000 / 2,000 / 5,000 / 10,000 5 ns/div. to 50 s/div. (Oscilloscope mode) 2.5 ns/div. to 50 s/div. (Oscilloscope mode) 100 ms/div. to 50 s/div. (Recorder Scan mode) Yes CH1, CH2, Ext, Ext/5, mains / automatic, triggered, one-shot - XY 100 ms/div. to 50 s/div. Edge, pulse width (20 ns-10 s), video (Pal, Secam, NTSC), slope, alternate, HOLD OFF from 10 ns to 1.5 s AC, DC, HFR (HF rejection), LFR (LF rejection) One-shot = 250 MS/s (2 channels), 500 MS/s (one channel) Repetitive = 50 GS/s One-shot = 500 MS/s (2 channels), 1 GS/s (1 channel) Repetitive = 50 GS/s 8 bits (vertical resolution 0.4 %) Max. depth = 32 kpoints "Unlimited" storage capacity (USB key) Max. depth = 2 Mpoints (long MEM) "Unlimited" storage capacity (USB key) Trace files (proprietary format and ".CSV" format compatible with spreadsheets) for the signals / Complete instrument configuration files / Screenshot files (Windows-compatible ".bmp" files) Minimum event duration = 10 ns Points or vectors Modes: Persistence (1 s, 2 s, 5 s, 10 s, 20 s or infinite) or Averaging (factor from 4 to 256) Yes AUTO adjustment of amplitude, time base and trigger position Trace calculated in "real time": CH1 and CH2 : addition, subtraction, multiplication, division FFT calculated on 1,024 points / Simultaneous display of trace + FFT / 4 window types (rectangle, Hamming, Hanning, Blackmann) Manual, tracking and automatic modes Pass / Fail on the basis of a limit envelope or a template Slow recording mode for signals > 100 ms (ROLL 6 Mpoints) 32 time or level measurements Yes 2 years CONTENTS 1 DOX digital analyser-oscilloscope, European mains power cable, 2 switchable voltage probes (1/1 and 1/10), USB A/B cable, CD-ROM containing PC software and user's manual TO ORDER 2 x 25 MHz digital oscilloscope 2 x 70 MHz digital oscilloscope 2 x 100 MHz digital oscilloscope DOX2025B DOX2070B DOX2100B DOX 2070B version: delivered with demonstration board for practical exercises: HX0074 ACCESSORIES See page 212 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3183 SPO BENCHTOP DIGITAL OSCILLOSCOPES DOX3000 FAMILY 28 Mpts FFT Math Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology COMPREHENSIVE WITH HIGH PERFORMANCE 100 and 300 MHz bandwidth with built-in 25 MHz generator and serial bus decoding 4-channel oscilloscopes with TFT screen 8 inches wide offering 256 levels of colour intensity. Display using Sensitive Phosphor Oscilloscope technology for optimized waveform capture: 110,000 wfs/s, exceptional acquisition and display functions for precisely reconstructing a signal. Maximum acquisition memory depth: 28 Mpoints. Practical, intuitive HMI with traditional front-panel commands (rotary knobs with lighting), 5 languages selectable by menu (English, French, Spanish, Italian and German) plus help in French and English. High-performance oscilloscope with maximum sampling rate of up to 2 GS/s in real time, vertical sensitivity from 2 mV/div. to 10 V/div. and from 1 ns to 50 s/div with complex and complete triggers (Pattern, windows, interval, Dropout, runt). A built-in 25 MHz arbitrary signal generator with programming software is included. Serial bus decoding function with integrated triggers: I2C, SPI, UART, CAN, LIN and MSO 8-channel digital logic analyser for analysing digital transmissions (DOXMSO3LA option). Easy analysis with 32 automatic measurements and statistical chart, manual cursor measurements and advanced math functions: simultaneous display of trace + 4-channel FFT. Communication: USB host, USB key and device (PC, Pictbridge printers) and Ethernet. CONTENTS 1 DOX digital oscilloscope, European mains power cable, 4 x 1/10 voltage probes, 1 USB cable, USB key containing software, user's manual and practical training exercises Demonstration board available for practical exercises: HX0074 1842 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com BENCHTOP DIGITAL OSCILLOSCOPES SPECIFICATIONS Interface Screen On-screen display Language Vertical deflection Bandwidth No. of channels Max. input voltage Vertical sensitivity Rise time Probe compensation factors Horizontal deflection Time base speed Max. no. of traces captured per second Horizontal zoom Auto ROLL mode Trigger system Sources/Mode Type Trigger on serial bus and decoding MSO logic analyser input Acquisition Real-time sampling frequency Vertical resolution Acquisition depth File manager Acquisition Peak detection "Statistics" mode Other functions AUTOSET MATH function FFT analyser Cursors PASS/FAIL Automatic measurements Built-in 25 MHz function generator General specifications Recording Printing Communication on PC Power supply Safety / EMC / Locking Temperature Mechanical specifications TO ORDER Oscilloscope (300 MHz, 4 channels) + arbitrary generator + serial bus decoding Oscilloscope (100 MHz, 4 channels) + arbitrary generator + serial bus decoding MSO 8-channel logic probe ACCESSORIES See pages 212 DOX 3104 DOX 3304 Colour 8" TFT LCD screen, 800 x 480 pixels, 24 bits On 8x14 div with 4 channels + reference + Math functions and statistics table full screen Vector or point modes with interpolation, permanent SPO mode: normal or colour English, French, German, Italian and Spanish 100 MHz - Bandwidth limiter: 20 MHz 300 MHz - Bandwidth limiter: 20 MHz 4 channels + 1 external channel 300 V (DC+AC Pk) 12 calibres from 2 mV to 10 V/div Accuracy ±3% 8-bit resolution < 3.5 ns < 1.2 ns x 0.1 / 0.2 / 0.5 / 1 / 2 / 5 / 10 / 20 / 50 / 100 / 200 / 500 / 1,000 / 2,000 / 5,000 / 10,000 1 ns/div to 50 s/div (oscilloscope) 110,000 traces/s Compression, expansion 100 ms/div to 50 s/div (1-2-5 step) CH1, CH2 or CH3. CH4 Ext, Ext/5, AC line / Auto, Normal triggered, One-shot Edge, Pulse (20 ns to 10 s), Slope (rising, falling), Video (NTSC, PAL, SECAM), Windows, Interval, Dropout, Runt, Pattern I2C, SPI, UART/RS232, CAN, LIN Option : 8 channels + clock for TTL/CMOS/LVCOM/CUSTOM signals 2 GS/s 8 bits (vertical resolution 0.4 %) Up to 28 M: 14 Mpts per channel, adjustable: 7 k / 14 k / 70 k / 140 k / 700 k / 1.4 M / 7 Mpts Trace files (DAV proprietary format and Excel-compatible ".CSV" format) ".set" configuration files ".bmp" screenshot files Normal, Peak detect, Average, High res Minimum event duration = 10 ns Event measurement AUTO adjustment: amplitude, time base and trigger Trace calculated in real time: CH1, CH2, CH3 CH4 +, -, x, /, (d/dt), integral (dt) and square root () FFT calculated on 1,024 points - simultaneously with the waveform for the 4 channels Adjustable windowing: rectangular, Hamming, Hanning, Blackmann Manuel, Track and Auto modes Pass/Fail mode with specific terminal for envelope adjustment 32 measurements and statistical table 25 MHz- 125 MS/s - 14 bits - arbitrary function generation with EasyWave Internal memory or USB flash memory on front panel Via USB Host (PictBridge) Via USB device or Ethernet link for EASYSCOPE (OX) and EASYWAVE (GX) software Universal 100-240 V / 45-440 Hz/ 50 VA max. with removable cable Compliant with the IEC 6101-1 standard, 300V CAT I - EMC as per EN61326-1 - Kensington lock Operation: 0 °C to +40 °C - Storage: -20 °C to +60 °C 352 x 111 x 224 mm 3.6 kg (4 channels) IP 20 3-year warranty DOX3304 DOX3104 DOX-MSO3LA TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3185 SOFTWARE FOR DOX FAMILY OF BENCHTOP OSCILLOSCOPES SOFTWARE FOR DOX FAMILY OF BENCHTOP OSCILLOSCOPES EASYSCOPEX is the PC data processing software for the oscilloscopes in the DOX family. It can be used to extend the oscilloscope's functions via USB (without drivers) or Ethernet (DOX 3000), depending on the models, for: ·R ecovery of the .csv trace files ·Transmission of programming commands (SCPI format) ·R emote command test via VIRTUAL PANEL ·Recovery of screenshots in .bmp format Available at the rear of the instrument: ·Input channel for the Pass/Fail mask test, ideal for quickly identifying problems on a signal ·Input channel for external triggering ·PC/device communication interfaces: USB or Ethernet ·Slot for KENSINGTON lock for greater security EASYWAVE is PC software which allows users to: ·R ecover the curves from the oscilloscope mode and then modify the waveforms using drawing tools ·Transfer or import waveforms into the ARBitrary function (4 memory locations) ·C onsult the file library (sine, square, ramp, pulse, noise, cardiac, exponential, etc.) in the memory of the oscilloscope's generator mode These software products are available from the DOX Support section on our website. Transmission of SCPI commands Screenshots Recovery of traces Virtual panel Creation of waveforms 1862 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com PORTABLE DIGITAL OSCILLOSCOPES > SELECTION GUIDE SELECTION FAMILIES Bandwidth Channels (number/type) IEC61010 safety One-shot digital sampling Repetitive mode with max. scale Vertical resolution Scaling/physical unit Ethernet/Wifi PC communication ScopeNet PC web server Ni-MH/LI-ION battery "Oscilloscope" specifications Min. input sensitivity Max. input amplitude Analogue filters Time base (per division) Roll mode / XY mode Memory depth Acquisition memory No. of reference or math curves on screen Automatic measurements/cursors Pulse trigger width/number Adjustable Hold-Off / delay Calculation functions: + - / x / : / advanced Autoset with channel selection Other functions FFT Lin & Log spectral analysis TRMS multimeters Logger Harmonic analysis Threshold recorders (no. of channels) Power / Power Harmonics measurement General specifications 7/3.5"colour LCD screen 100% "closed casing" software calibration FIELDBUS OX9302 BUS 300 MHz 2 isolated 2.5 GS/s 100 GS/s 12 bits ·/· ·/· · -/· MULTIFUNCTION "STAND-ALONE" SCOPIX IV ELECTRONICS ELECTRICAL INDUSTRIAL OX9304 OX9104 OX9102 OX9062 300 MHz 100 MHz 60 MHz 4 isolated 2 or 4 / isolated 2 isolated CAT-II 1000V/CAT-III 600V 2.5 GS/s 2.5 GS/s 2.5 GS/s 100 GS/s 100 GS/s 100 GS/s 12 bits 12 bits 12 bits ·/· ·/· ·/· ·/· ·/· ·/· · · · -/· -/· -/· HANDSCOPE MAINTENANCE OX5022B OX5042B 20 and 40 MHz 2 isolated 50 MS/s 2 GS/s 9 bits ·/· ·/- 156 V/div in zoom mode 2.5 mV/div 5 mV/div 200 V/div 200 V/div 15 MHz, 1.5 MHz, 5 kHz 15 MHz, 1.5 MHz, 5 kHz 15 MHz, 1.5 MHz, 5 kHz 15 MHz, 1.5 MHz, 5 kHz 1.5 MHz, 5 kHz 1 ns-200 s 1 ns-200 s 1 ns-200 s 1 ns-200 s 25 ns-200 s ·/· ·/· ·/· ·/· ·/· 100 k/channel > 2 GB on SD card (all formats) 100 k/channel > 2 GB on SD card (all formats) 100 k/channel > 2 GB on SD card (all formats) 100 k/channel > 2 GB on SD card (all formats) 2.5 k/channel - 2 MB memory 4 4 4 2 2 20/· ·/· ·/· ·/· ·/· - ·/· ·/· ·/· ·/· - ·/·/·/· ·/·/·/· ·/·/·/· ·/·/·/· ·/·/· · · · · · 12 bits / 72 dB+ waveform 200 kHz 63 orders 2 ·/- 12 bits / 72 dB+ waveform 12 bits / 72 dB+ waveform 12 bits / 72 dB+ waveform 200 kHz 200 kHz 200 kHz Recording in MULTIMETER mode, 100 kpts file 63 orders 63 orders 63 orders 4 2 ou 4 2 ·/- ·/- ·/- 50 kHz 31 orders 2 · 7" 7" 7" 7" 3.5" · · · · · TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3187 PORTABLE OSCILLOSCOPES SCOPIX IV, A RANGE OF 5 REFERENCES 54 wi Fi MICRO SD Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology The IVth generation of SCOPIX oscilloscopes: a range of 4 general-purpose references and one product reference specialized in BUS testing. From the laboratory to the field, whether placed flat, suspended or carried, a single multifunction diagnostic instrument with isolated channels is all you need: sober, rugged and complete, the alliance of technology and field expertise in one oscilloscope. OSCILLOSCOPES WITH ISOLATED CHANNELS FOR HIGH-PERFORMANCE MEASUREMENT OF ELECTRICAL QUANTITIES ·P ractical and easy to use, this generation of on-site oscilloscopes with software organized by tablet/smartphone icons developed on a LINUX operating system ·Optimized display with a backlit 7-inch WVGA colour touch screen organized into areas: upper display area for zoom and FFT, lower area for the measurement parameters. ·N ew mechanical technologies, with a 30-key silicone keypad for direct commands, casing optimized for comfortable handling for work in industrial environments: IP54, resistant to dust, humidity and water droplets, as well as temperature variations. Noiseless because there is no fan. Supplied with stand and carrying strap ·Simplification of input terminals with Probix "plug&play" smart sensors: safety, power supply via Scopix, automatic recognition, automatic scaling ·All types of communication interfaces are available: USB and Wifi or wired Ethernet + SD + calibration signal grouped on the right-hand side of the product · SD large capacity storage above 32 GB: SD, SDHC and SDXC cards, 1 GB internal storage ·D ata processing tools: ScopeNet software for controlling "100 % of the functions", recovering the data, exchanging files on PC or SX-METRO software for data analysis on PC, as well as .png screenshots on network printers ·Battery life of one working day in the field with Li-ion battery > 8h (battery life indicator) or mains: removable battery without hatch to open, fast charging inside the instrument HIGH PERFORMANCE: 5 COMPLEMENTARY TOOLS IN A SINGLE INSTRUMENT, WITHOUT CHANGING THE CONNECTIONS ·O scilloscope + multimeter + FFT analyser + harmonic analyser and logger with simplified use ·O X: Bandwidth up to 300 MHz, on 2 or 4 isolated channels, 600 V Cat III 1000 V with voltage probe ·Sampling rate 2.5 GS/ s in one-shot mode and max. 100 GS/s in ETS zoom mode ·1 00 K memory depth per channel (oscilloscope & logger). Standard "real-time" FFT analysis and "functions for simple" and complex calculations on the channels ·2 or 4 multimeters + independent TRMS digital loggers, bandwidth 200 kHz ·Powerful, with a latest-generation high-speed microprocessor offering 12-bit resolution MEASUREMENT OF ALL SIGNALS ·D igital isolation of the channels between one another and in relation to the earth, 600 V CAT III 1882 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com DUAL-DISPLAY TRMS CLAMP MULTIMETERS INTEGRATED MODES OF THE ANALYTICAL TOOLS FOR USE WITHOUT CHANGING THE MEASUREMENT INPUT OSCILLOSCOPE MODE: 2 OR 4 CHANNELS, 60 TO 300 MHZ Complete automatic measurements for precise analysis display all the 20 parameters of a signal all together or for each of the four channels, as well as the 2 markers allowing you to view the portion of the signal where the first automatic measurement was made. A specific measurement area can then be selected by framing it with manual cursors for more reliable and accurate results. It is possible to compare two traces directly by checking "deviation from reference memory" so that the signal's 20 parameters are shown as deviations. The MATH functions (1, 2, 3 and 4) can be used to define, for each of the traces, a mathematical function and vertical scaling with the definition of the actual physical unit. The screen of the mathematical editor can display up to 4 traces in real time. Automatic or cursor measurements remain available. This means it is possible to examine waveforms such as the power, for example (U x I), and perform all the related measurements. many operators are available, such as +, -, x, /, but more complex functions such as sine, cosine, exponential, logarithm, square root and even derivative and integral, etc., at last opening the way for specific applications. The real-time Fast Fourier Transform (FFT) for frequency decomposition of your signals. The FFT function is used to calculate, on the basis of 2,500 points, the discrete representation of a signal in the frequency domain alongside its simultaneous representation in the time domain. It is often crucial for developing an effective diagnosis during qualitative analysis of the signals measurement of the different harmonics. Several weighting windows are available, as well as 2 representation modes (linear or logarithmic, scale in dB). The 2 cursors can then be used for precise measurement of the frequency lines, the levels and the attenuations, taking advantage of the 80 dB dynamic range permitted by the 12 bits / 2.5 GS/s conversion. The Autoset function makes it easier to obtain an optimum spectral representation on which a graphical zoom can be applied to analyse all the details of the spectrum. MULTIMETER MODE By simply selecting the dedicated pictogram, you can access the multimeter without changing the input channel: - amplitude (DC or AC voltage and current, power, temperature, etc.) - resistance, continuity, capacitance - SMD tests, etc. Temperature can be measured with PROBIX Pt 100 sensors or K thermocouples for direct measurements in °C. The Logger mode is associated with Multimeter mode so that you can view the trends. POWER Power measurements are proposed with a choice of three configurations: · single-phase power · three-phase power on balanced network without neutral · three-phase power on balanced network with neutral LOGGER MODE WITH AUTOMATIC RECORDING Since version 1.05 of the firmware, it is possible to analyse the events in the Logger mode's Viewer by means of search criteria and a duration; if it is possible to select an event, the cursors are displayed. Logger mode: recording of the trends from the Multimeter mode, simple switching between the two modes. For monitoring the variations of physical or mechanical phenomena over time, a genuine fast graphical digital logger is integrated into the instrument to replace paper recorders. The recordings have a fixed duration of 20,000 s with a sampling interval of 0.2 seconds and are automatically saved in N files of 100 kpts. HARMONICS MODE Harmonic analysis is performed up to the 63rd order to meet the requirements of the EN 50160 standard (THD on 50 orders minimum), with a fundamental frequency between 40 and 450 Hz. It is possible to preselect the frequency of the fundamental for the standards (50 Hz, 60 Hz and 400 Hz). This function helps to improve analytical performance and above all allows measurement when the level of a harmonic order is greater than the level of the fundamental. It is possible to view harmonic analyses on two or four channels simultaneously. "BUS ANALYSIS" MODE YOU CAN SELECT "BUS ANALYSIS" MODE BY PRESSING AN IMAGE; ALL THE TESTS ARE AUTOMATIC ONCE YOU HAVE CHOSEN THE BUS. 1 - Choice of the bus among ASI-DALI-CAN-KNX-ETHERNET-MIL STD1553-ARINC159USBFLEXRAY-LIN-PROFIBUS-RS232/RS485 in a list with different speeds, 2 - Measurement limits or tolerances of the bus chosen, 3 - Diagnosis, 4 - Indication of diagnosis with elements to be checked. · Choice of the bus by means of the BUS: configuration icon Display of all the definition files for bus tests according to the different speeds. · Selection of one of the files before starting analysis; for each bus: reminder of the configuration: standard and speed, limits and type of protocol. On the right, a "connection" area shows details of the probe connections for each channel. · Analogue analysis of the bus chosen beforehand. Display during automatic diagnosis Display of the measurement tolerances · TOLERANCES To analyse the current bus, you need to view the tolerances assigned to each measurement. These tolerances may be modified by the user; the bus will then be displayed with an asterisk (*) beside the filename. · RESULTS Display of the results from the last analysis available. These results can be saved in a ".htm" file in the internal memory or on the SD card and can be reopened in a text editor. TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3189 TEST & MEASUREMENT > PORTABLE OSCILLOSCOPES > OX 9302-BUS OX 9302-BUS wi MICRO 54 Fi SD Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology A genuine SCOPIX IV oscilloscope with all its modes and tools plus the BUS function! STRENGTHS · 1 key to start analysing · 4 steps to qualify a data bus · Intuitive, upgradable Human-Machine Interface · Multi-interface communication · Customization of your fieldbus with the SX-BUS software delivered with the product · Verification of the transmission quality of signals using fieldbus protocols: KNX, DALI, CAN, LIN, FlexRayTM, AS-i, Profibus®, RS-485, RS-232, Ethernet, etc. SPECIFICATIONS OX9302-BUS Type of display 7" TFT WVGA LCD colour touch screen, 800 x 480 pixels LED backlighting (adjustable automatic standby) Bandwidth Number of channels 300 MHz 2 isolated channels The SCOPIX IV BUS function can be used to perform the electrical measurements needed to assess the integrity of the fieldbuses, or in other words the operation of the physical layer (electrical specifications, synchronization, etc.), according to the applicable standards. Once diagnosis of the bus has begun, it proceeds step by step, with the possibility of viewing the calculation of the various parameters imposed by the standard. Efficiency: if the diagnosis stops before the measurements have ended, it means that the minimum level and amplitude criteria are not satisfied, so the other parameters cannot be calculated. 1- Choice of the bus to be analysed from a list. 2- Display of the measurement tolerances. 3- Analysis of the bus according to the associated standard. 4- Result of the analysis with assistance for interpretation. SCOPIX BUS proposes help with connection according to the bus to be checked, along with the corresponding wiring diagram. The five HX0190 and HX0191 boards delivered help you with the connections: these boards are equipped with SUBD9, RJ45 or M12 connectors or 8-wire screw connectors which are the main technologies used for connection to fieldbuses. TO ORDER 1 oscilloscope 2 x 300 MHz BUS 1902 OX9302-BUS TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com TEST & MEASUREMENT > PORTABLE OSCILLOSCOPES > SCOPIX IV The functions and performance of the SCOPIX IV models have been improved. For example, their bandwidth has been increased, as have their recording possibilities, their storage capacity, etc., and this evolution will continue to facilitate your measurements. Selection families Bandwidth Channels (number/type) Analogue filters One-shot digital sampling Max. scale repetitive mode Vertical resolution Safety as per IEC61010 Display mode Type of signals Averaging "Oscilloscope" specifications Min. input sensitivity Max. input amplitude Time base (per division) FFT+signal mode XY mode Memory depth Acquisition memory Automatic measurements/cursors Edge trigger Pulse trigger Delay trigger Counting trigger Adjustable Hold-Off / Delay Calculation functions Autoset Other functions TRMS multimeters Logger Harmonic analysis No. of channels / Viewer Power measurements General specifications Colour screen LI-ION battery Recording conditions Communication RJ45/Wifi Electronics OX9304 300 MHz 4 isolated Scopix IV Electrical OX9104 OX9102 100 MHz 2 or 4 / isolated 15 MHz, 1.5 MHz, 5 kHz 2.5 GS/s 100 GS/s 12 bits 600 V Cat III Vector, envelope, entire acquisition Automatic ROLL (> 100 ms), repetitive, min/max 2/6/16/64 Industrial OX9062 60 MHz 2 / isolated 156 V/div (zoom) 2.5 mV 200 V/div 1 ns - 200 s 2,500 pts, logarithmic and linear scale, weighting window Depending on time base X(T) + waveform 100 kpts / channel > 2 GB on SD card (all formats, SDHC/XC cards) 20 automatic measurements + cursors Rising or falling on 2 or 4 channels < T1 ; >T2 ; or between T1 and T2: [16 ns, 20 s] 48 ns to 20 s and trigger on 2 or 4 channels 3 to 16,384 events and trigger on 2 or 4 channels Adjustable from 64 ns to 15 sec Simple + - / x / : / and advanced: complex functions, integral, derivative With channel selection 200 kHz 200 kHz 200 kHz REC in Multimeter mode / 100 kpt file / period 0.2s 63 orders, Vrms, global THD and per order 4 4 or 2 2 Single-phase, three-phase, display Active, reactive and apparent power, PF + t MIN/MAX 7 wide - Resolution 800 x 480 pixels Battery life: 8 hours 1 GB internal data storage, 2 GB to 2 TB SD card ScopeNet IV for PC and SX-METRO/P software (option) CONTENTS 1 SCOPIX IV oscilloscope delivered with a carrying bag, 1 PA40W-2 mains power pack/charger and 1 2P EURO mains power cable, 1 Li-Ion battery pack, 1 stylus, 1 Ethernet cable, 1 USB cable, 2 safety leads (red, black), 2 x Ø 4 mm test probes (red, black), 2 or 4 voltage probes depending on model, 1 SD card (8 GB), 1 USB / SD adapter, 1 wrist strap, 1 PROBIX BANANA connector, 1 USB installation procedure for use of the ScopeNet data export software on CD-ROM, 1 PDF user's manual on CD (more than 5 languages), 1 Quick Start Guide on paper and 1 safety datasheet in 20 languages. ACCESSORIES SX-METRO/P See PROBIX accessories TO ORDER 1 oscilloscope 2 x 60 MHz 1 oscilloscope 2 x 100 MHz 1 oscilloscope 4 x 100 MHz 1 oscilloscope 4 x 300 MHz p53 p50 OX9062 OX9102 OX9104 OX9304 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3191 TEST & MEASUREMENT > PORTABLE OSCILLOSCOPES > PROBIX ADVANTAGES OF THE PATENTED PROBIX SYSTEM Scopix portable oscilloscopes benefit from Probix smart accessories which offer users a host of innovative functions guaranteeing simplicity, effectiveness, versatility and safety. The Probix system, with its smart probes, accessories and adapters, ensures quick, error-free implementation of your instrument. With this "plug and play" measurement system, the probes and adapters are recognized immediately as soon as they are connected. The instrument does not just identify them, however. It also gives information on their specifications. Active safety is built-in, notably in the form of safety information and recommendations for users based on their specific configuration. The coefficients, scales, units and channel configurations are managed automatically. This system also allows users to power the accessories directly from an oscilloscope, without a battery or additional mains adapter. Some Probix accessories include three control buttons directly accessible on the probe. For example, the first two control buttons on the probes are used for direct modification of the parameter settings for the channel to which they are connected. PROBIX MEASURING ACCESSORIES (CURRENT, VOLTAGE, TEMPERATURE) Connections Measurement Measurement range type Ratio Probe BNC Banana Clamp AmpFLEX SK1-20 Mini AmpFLEX SK1-19 sensors SP10-13 sensors HX0130 HX0030C HX0031 HX0032 HX0033 HX0093 HX0034B HX0072 HX0073 HX0094 HX0035B HX0036 Ø26 mm 1/10 · 1/10 · · 50 · · · · · · · 300 V CAT II 500 MHz 600 V CAT III 250 MHz 600 V CAT III 250 MHz 30 V CAT I 250 MHz 600V CAT III 600 V CAT III 300 Hz filter 0.2 - 60 Arms 1 MHz 5 - 300 Arms 200 kHz 1 - 300 Arms 3 MHz 4 - 20 mA · -10 °C to +1,250 °C · -100 °C to +500 °C Voltage-ResistanceCapacitance-Tester Voltage-ResistanceCapacitance-Tester Voltage-ResistanceCapacitance-Tester Voltage-ResistanceCapacitance-Tester Voltage-ResistanceCapacitance-Tester Voltage-ResistanceCapacitance-Tester Current Current Current Current Temperature K thermocouple Temperature Pt100 sensor PROBIX ACCESSORIES SMD banana lead Industrial accessories kit SD-SD USB-SD Demo. test circuit BNC/BNC 100mV clamps Specifications 45 Aac 60 Aac 200 Aac 45 Aac/dc HX0064 HX0071 0X 9XXX 0X 9XXX 0X 9XXX HX0106 MA200 MN60 C160 HX0102 Probix HX0033 HX0030C HX0031 HX0031 HX0031 HX0031 HX0031 Other accessories HX0179 HX0080 HX0074 FIND ALL THE AVAILABLE ACCESSORIES, SENSORS AND CLAMPS IN THE ACCESSORIES CHAPTER. 192 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com TEST & MEASUREMENT > PORTABLE OSCILLOSCOPES > SCOPIX IV THE COMMUNICATION TOOLS IN SCOPIX IV The communication interfaces are grouped in a dedicated area on the right-hand side of the product and are protected by plugs: USB host, wired or Wifi Ethernet for communication with a PC or printing on a network printer and high-capacity SD card for storing the data without transfer problems. DATA PROCESSING You can choose the type of communication to suit your changing requirements: · R J45 wired Ethernet LAN with integrated DHCP server for simple connection to your network and the possibility of activating the Wifi radio link to communicate with a PC. · USB type A to interface with a PC to save, recall or load configurations. · SD card for storing data and upgrading the firmware; this direct interface does not require a link. FILE MANAGEMENT It is possible to save the traces from the oscilloscope mode in two formats: .trc so that they can be recalled to the screen or.txt for direct export into another standard "Windows"' application, such as a spreadsheet, for example. · On the oscilloscope, recall of .trc curves stored in the memory by means of a png viewer. · O n a PC, with the ScopeNet application in your web browser via USB or Ethernet: remote control, programming using SCPI commands or via the SX-METRO software. · T he multiple communication tools with SCOPIX IV will enable you to view the curves in real time on a PC, perform additional measurements and analyses remotely, take screenshots and control your oscilloscope. SCOPIX IV provides comprehensive postacquisition expert functions. It is also very simple on the oscilloscope's front panel to take screenshots in .png format (stored in the screenshot directory), print on a network printer and transfer or delete files in the file manager. In each mode, the configuration can be saved to simplify your settings. TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3193 TEST & MEASUREMENT > SOFTWARE FOR OSCILLOSCOPES > SCOPENET APPLICATION FOR SCOPIX IV ScopeNet IV · S copeNet IV is a PC application which uses Ethernet communication (wired RJ45 and Wifi) The ScopeNet IV PC application for SCOPIX IV can be used to: · control and configure the oscilloscope remotely · display the acquisitions as curves in all the modes · recall or save instrument configurations, · make and recall screenshots in .png file format. It can also be used to : · recover files from the SCOPIX IV remotely, · take screenshots which are then placed in the clipboard. There is no function for exporting the data into Excel because a.txt text editor is available on the instrument; it converts .rec and .trc files into .txt files so that the points can be used in a spreadsheet such as Excel: The memory card appears in the tree-structure as "sdcard-p1" Logger Oscilloscope File manager Multimeter Harmonics Practical No need to install Scopenet on the PC. The application opens directly with most web browsers. Android application ScopeNet for Scopix III (available from Google Store) ScopeNet for remote dialogue and configuration using a tablet or smartphone. This can be used to view the curves in real time, perform measurements and analyses, capture screens and control METRIX oscilloscopes METRIX with your tablet or smartphone. 1942 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com TEST & MEASUREMENT > ACCESSORIES FOR OSCILLOSCOPES > APPLICATIONS SX METRO USB-RS232 or Ethernet link The METRIX oscilloscope software for: · Viewing the curves: up to 5 per screen · Displaying the curves on a PC in real time as well as on the oscilloscopes · Controlling the oscilloscope remotely with the PC · Loading a configuration into the oscilloscope · Importing curves stored in the oscilloscope's memory as "image" files · Storing the curves in text format on the PC · Performing mathematical processing such as FFT on the signal viewed · Transferring the data (curves or FFT) into Excel File format * .trc * .rec * .cfg * .bmp * .grf * .per * .png * .BUS Contents a curve which will be displayed in the active graph. a recording which will be displayed in a new graph. configuration. SCOPIX III screenshot. graph with curves and comments. a curve in persistence mode. SCOPIX IV screenshot. Bus analysis file. Reminder of the communication at the foot of the SX METRO screen: the status bar shows the type of connection to the oscilloscope and the real-time control options. 1- Control: for directly activating remote control of the oscilloscope. 2- ScopeNet IV: for starting the JAVA application for SCOPIX IV. SX METRO offers a help file which refers to a .pdf file of the SX METRO user's manual. The SX-METRO software is regularly upgraded, so we advise you to check your version is the same as the version present on our support website ht tps : / / w w w.chauvin-arnoux.com / fr / suppor t / telechargement / result s / nid / 19 9 4 6 The same applies to the SCOPIX IV firmware. https://www.chauvin-arnoux.com/sites/default/files/download/x04726k00.zip The 5 tabs accessible in SX METRO 1- "File" groups file creation, data backup or window closure, file import from the oscilloscope's memory or export of traces or configurations into the memory. 2- "Edit" proposes processing of the window, addition of text and screenshots. 3- "Options" manages the type of communication according to the output port or cable used, the settings for the communication parameters, a function for exporting trace files into Excel and the choice of one of the 5 languages proposed. Options/control allows you to view the instrument's front panel in real time with the parameter settings. 4- "Display" of the crosshairs, deviation cursors and different screen sizes for optimized viewing. With the colour function, you can modify the colours of the different objects in the SXMETRO window and thus print your curves in the format you wish in order to optimize printing according you your printer. 5- "Help" calls up a .pdf of the SX METRO User' Manual; a link to an upgrade file on our support website has been added. This website also indicates the current SX METRO version. ACCESSORIES USB/microSD adapter: HX0080 TO ORDER Software for OX7000, OX9000, OX6XXX and OX5XXX TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com SX-METRO/P 3195 TEST & MEASUREMENT > LABORATORY PRODUCTS SIMPLE, EFFECTIVE INSTRUMENTS FOR MEASUREMENTS IN THE LABORATORY A large number of measuring instruments are necessary to design new instruments and systems in R&D laboratories. The engineers and technicians responsible for designing electronic, IT and process control systems use a wide range of measuring instruments from the design phases through to testing and qualification. From the simplest to the most complex, from single-function instruments to multi-application models, the laboratory instruments from Metrix offer users a wide choice focusing on effectiveness and accuracy. RESEARCH & DEVELOPMENT During this phase, the main laboratory instruments required provide the following functions: · Power supplies · Signal generation · General measurements · Time and frequency analyses of the signals To meet these requirements, we propose a set of simple, effective standard or programmable multichannel power supply solutions, as well simple and random function generators. When these generators are used with the SX-GENE software, they can simulate complex signals. In addition, the advanced functions and high accuracy of the benchtop multimeters in the MX5000 Series and the ASYC IV family allow you to measure the various electrical values of a circuit. With our digital oscilloscopes offering, time and frequency analysis of the signal is guaranteed at bandwidths of up to a few hundred megahertz. TESTS AND QUALIFICATION Testing is now recognized as a specific profession which is essential for successful projects. It allows you to work on both technical and functional issues. Omnipresent throughout the development cycle, testing is an activity which draws on a wide range of knowledge and knowhow, including the use of reliable, accurate instruments. During this phase, tests are carried out to check both the system's performance and its ability to operate in its environment. Chauvin Arnoux proposes suitable measuring solutions for this to complement the instruments described above. The numerous integrated functions of the Handscope and Scopix portable oscilloscopes with isolated channels can be used to perform measurements on integration platforms. Simultaneously multichannel oscilloscopes, multimeters, signal analysers (including of digital bus signals conformity of time and levels) and loggers, they can be used to check and note the various points to be tested. Thanks to their communication interfaces and related software, the measurements are collected and made available to produce a measurement report. The near-field probes used with the MTX1050 spectrum analyser can be used for initial diagnosis in terms of electromagnetic disturbances affecting a PCB. FROM MIDDLE SCHOOLS... TO HIGHER EDUCATION When studying Science and Technology, measurement is essential for assessing and understanding the theoretical phenomena through practical experiments. In both initial and higher education, it is important to determine the characteristics of a component or system, its behaviour in its environment and its evolution over time, using our measuring instruments Our offering covers everything from easy-to-use instruments for initial training through to the more complex tools encountered by students when they start their working life. SPECTRAL ANALYSIS Spectrum analysis can be used to measure the band, detect disturbance lines, quantify phase jitter by direct reading, check the steps, determine the rated frequency, search for residual lines for comparison, etc. HETERODYNE SPECTRUM ANALYSER Spectrum analysis involves moving a narrow bandwidth filter in front of the signal to be analysed. However, because of the difficulty of producing a narrow bandwidth filter with an adjustable mid-band frequency, the problem is avoided by "heterodyning". With this technique, the bandwidth filter has a fixed midband frequency of F0 and the signal to be analysed is modified by modulation, so that the different frequency components are successively modulated to the frequency F0. To achieve this, a multiplier is used which outputs the sum and the difference of the frequencies applied to the two inputs, resulting from the trigonometric relation: cos(a)cos(b) = (1/2)[cos(a+b) + cos(a-b)]. THE ANALYTICAL FILTER The analytical filter is also called the resolution filter. The narrower the filter, the finer the analysis and the closer you get to the shape of the line analysed (because the filter itself resembles a line). Using different reasoning, it could also be said that a signal passing through an extremely narrow filter can only come out as a pure sine wave, represented by a line! Width of analytical filter NOISE MEASUREMENT DEPENDS ON THE WIDTH OF THE ANALYTICAL FILTER This means that phase jitter can be measured with the spectrum analyser, in dBc/Hz, which is the difference in dB between the F0 line power measurements in dBm and the noise power in dBm/Hz at a given distance from the carrier. VIDEO FILTER This serves to smooth the curve on the screen, particularly at the noise level. It has no effect on the actual measurement, as it only applies to the on-screen display of the curve. However, it may affect the sweep time: a 10 Hz video filter will not deliver more than 10 data items per second, so if 1,000 points are necessary to plot the curve, it will not be possible in less than 100 seconds. Block diagram of a heterodyne spectrum analyser NOISE POWER AND POWER OF A LINE The analytical filter indicates the power of the F0 line when it is centred on it (leaving aside the filter losses which can be compensated). Whatever the width of the filter, the maximum height of the curve on screen will correspond to the power of the line. Noise measurement with several analytical filters 1962 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com TEST & MEASUREMENT > SELECTION GUIDE FOR LABORATORY INSTRUMENTS SELECTION GUIDE FOR LABORATORY INSTRUMENTS SPECTRUM ANALYSER GENERATORS FOR LABORATORY INSTRUMENTATION LABORATORY POWER SUPPLIES 197 PROGRAMMABLE POWER SUPPLY 198 MULTIFUNCTION CALIBRATORS TRAINING BOXES AND SHUNTS 200 SELECTION GUIDE WE PROPOSE A RANGE OF LABORATORY PRODUCTS FOR YOUR EXPERIMENTS AND PRACTICAL EXERCISES The school and university labs used for practicals are traditionally equipped with stabilized or adjustable power supplies protected against short-circuits and function generators, from the simplest (sine, square and triangular waveforms) to the most complex (arbitrary signals) to complement the multimeters and oscilloscopes. · Analyser The MTX 1050 is a very compact, ergonomical "screenless" instrument. Lightweight, portable, ideal for general-purpose applications, the MTX 1050 is particularly suitable for the needs of SME/SMIs and technical education (engineering schools, technical colleges, etc.). Laboratory spectrum analyser with PC software · Generators The GX 3xx models are 5 MHz to 20 MHz DDS function generators which provide significantly better accuracy and frequency stability than a classic generator. they generate precise, varied signals: sine, triangle, square & LOGIC waveforms with TTL output. The backlighting is adjustable and the contrast can be increased if needed. 15 complete configurations are stored in the memory of version -E of the GX 320, which is programmable via an ETHERNET link using the SCPI protocol. The GX 10xx models are 25 MHz or 50 MHz arbitrary signal generators. They are accurate, stable and the signals are pure, with low distortion due to the 125MS/s sampling rate with 14-bit resolution. The SX-GENE v2.0 software can be used to control a GX 10xx arbitrary signal generator, save and restore configurations and generate arbitrary signals. Simple and complex DDS function signal generators · Frequency 5, 10 or 20 MHz · 25 or 50 MHz arbitrary signal generators with SX GENE PC software · Power supplies The AX50X models are 30V/2.5A variable laboratory power supplies with 1, 2 or 3 channels. These power supplies are rugged but lightweight and economical and generate very little radiation. The AX1360-P is a triple programmable regulated power supply with 2 adjustable outputs (0-30 V) and 1 selectable fixed output (2.5V / 3.3V /5V). The AX1360-P is simple to use as it allows you to change from a serial circuit to a parallel circuit without rewiring, by simple selection, and the switch been the 2 modes is automatic. Stabilized laboratory-current power supplies for powering your circuits 206 207 208 210 1 channel 2 channels 2 channels + 1 fixed Tracking mode Programmable AX501 · Power supply selection guide AX502 · · AX503 · · · · · · Calibrators Multifunction calibrators suitable for calibrating all types of measuring instruments/ The CX 165x models include a built-in multimeter. Laboratory calibrators · Decade boxes and shunts Single or multiple laboratory decade boxes for resistance, capacitance and inductance exercises Laboratory shunts TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com AX1360-P · · · · · 3197 TEST & MEASUREMENT > SPECTRUM ANALYSER CONNECTED TO A PC > MTX1050 MTX1050 CAT II Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology ADDITIONAL INFO · When coupled with the H-field probes, the MTX1050-PC analyser can be used to carry out EMC prequalification tests. STRENGTHS · Particularly compact and economical "screenless" instrument · User interface via PC: "Plug & Play" USB connection, large high-resolution colour display · 4 simultaneous measurements (Peak auto, Marker, 2 difference cursors) · Frequency range from 400 kHz to 1 GHz · High stability with frequency drift limited to ±5 ppm/year · Wide dynamic range for measurement, from -90 dBm to +20 dBm · 6 sweep speeds, 3 analytical filters and 3 video filters, built-in FM demodulation · Ideal for EMC testing PEAK cursor Free cursor DELTA cursors 1982 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com TEST & MEASUREMENT > SPECTRUM ANALYSER CONNECTED TO A PC > MTX1050 SPECIFICATIONS Frequency Display Bandwidth Resolution on value / central frequency Internal frequency Frequency stability Frequency span Resolution Filters Video filters Level Dynamic range for input Dynamic range for display Input Max. admissible power Impedance Input attenuation Connector Markers / modes Functions Data storage PC communication Mains power supply Safety / standards Dimensions / weight MTX 1050 15 MHz, 1.5 MHz, 5 kHz Colour display, high resolution, large dimensions, on PC screen Up to 5,000-point sweep in horizontal resolution (depending on speed) 400 kHz to 1 GHz 4 1/2 digits / 10 kHz max. Accuracy ±0.625 10-6 ±5 ppm / 1 year Zero Span, 1 MHz to 100 MHz / div - sequence 1-2-5 12 kHz, 120 kHz and 1 MHz 1 kHz, 10 kHz and 300 kHz 3 ranges from -90 dBm to +20 dBm 50 dB and 100 dB Max. admissible power +25 dBm permanent, ±30 Vdc 50 rated One 20 dB-rated attenuator, one 20 dB-rated amplifier BNC 4 simultaneous cursors / 1 automatic "Peak" detection marker, 1 cursor "locked" to the trace and 2 delta cursors On PC, unlimited number, with explicit names Storage and comparison of reference spans 100 to 5,000 samples per sweep (depending on sweep speed) "Plug & Play" USB as standard 230 Vac, ±10 %, 50/60 Hz, approx. 4 W IEC 61010-1 - CAT II / NF EN 61326-1: 98 270 (L) x 63 (H) x 215 (W) mm / 1.7 kg SPECIFIC ACCESSORIES H field probes kit, 3 GHz 20 dB amplifier for HX0082 probes HX0082 HX0083 CONTENTS 1 MTX, 1 mains power cable, 1 CD-Rom containing the PC application software, 1 FM antenna with BNC connection, 1 user's manual TO ORDER MTX 1050PC spectrum analyser MTX1050-PC TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3199 TEST & MEASUREMENT > GENERATORS FOR LABORATORY INSTRUMENTATION GENERATOR BASICS Function generators are among the most widely-used test and measurement instruments. They can generate varied characteristic waveforms in order to test the operation of electronic systems, from very low frequencies of just a few mHz up to 20 MHz or more. They allow users to adjust the amplitude of these signals up to 20 V or more, possibly with the presence of a DC component. In addition, they may also provide modulations or specific functions. DIRECT DIGITAL SYNTHESIS (DDS) FUNCTION GENERATOR Basic principle: DDS function generators generate periodic signals at precise frequencies by choosing samples in the memory rather than producing all the samples of a signal. This technique offers exceptional accuracy and stability, high spectral purity, low noise and excellent frequency agility. It is possible to modify the frequency without phase discontinuity. It is important to note that signal generation with the DDS method differs significantly from the method used by an arbitrary signal generator. For arbitrary signal generation, each sample of the signal period built and stored in the memory is generated sequentially. For signals generated with DDS technology, a single signal period is stored in the memory, but only certain samples are generated to create the waveform and the required frequency, as shown in the illustration below: Direct Digital Synthesis (DDS) function generator Generation of a 21 MHz signal with direct digital synthesis (DDS) A FEW DEFINITIONS Signal waveforms The generator can typically generate sine, triangle and square waveforms, as well as their usual derivatives. Frequency range (expressed in Hertz (Hz) This is the difference between the minimum frequency and maximum frequency that the generator is capable of producing. This frequency range is defined for a sinusoidal waveform. It should be noted that a smaller frequency range is usually specified for triangular or square waveforms. The minimum frequency, which may be just a few mHz, is used to simulate slow phenomena (mechanical or physical) or to control slaving (for example, a triangular ramp profile). Resolution This is the smallest measurable value difference. It is expressed in digits and its absolute value depends on the frequency range used. For the GX320, for example: 5-digit resolution at 20 MHz corresponds to a 1 kHz increment. Frequency accuracy This corresponds to the difference between the true value of the signal's frequency and the value displayed. It mainly depends on the quality of the oscillator used, for which short-term and long-term stabilities are defined, expressed in ppm (parts per million). For example, for the GX320: +/- 20ppm when F > 10 kHz. SWEEP function The "SWEEP" function can be used to generate a frequency sweep in rising or falling mode. This sweep can be controlled by the generator according to a linear or logarithmic law or on the basis of an external sawtooth or triangular signal applied via a dedicated BNC connection. Types of modulation AM: Amplitude Modulation FM: Frequency Modulation FSK function: Frequency SKip controlled internally or externally. PSK function: "Phase SKip" whose value is controlled by an internal or external command signal. BURST function The BURST function can be used to generate pulse trains: users define the train generation period and the number of pulses in the train. It also provides a means of generating a signal with a very large duty cycle (1 brief pulse with a long repetition period). GATE function This superimposes over the active function a start/stop command for the AC component of the MAIN OUT signal. This function can be controlled internally or by a TTL signal injected on a dedicated BNC connection. MASTER/SLAVE function This can be used to synchronize several GX 320s set up in a "cascade" arrangement. The generator used as the "Master" supplies the other "Slave" instruments with the clock (Clk) and a synchronization signal (Ctrl). This enables all the generators to start up at the same time and allows users to control their phase shift. 2002 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com TEST & MEASUREMENT > GENERATORS FOR LABORATORY INSTRUMENTATION SELECTION GUIDE FUNCTION GENERATORS SPECIFICATIONS SPECIFICATIONS Number of channels Max. frequency (MHz) Display Signal waveforms Sweep AM/FM modulation FSK/ASK function BURST function GATE function MASTER/SLAVE function Frequency meter Pages GX305 1 5 · GX310 1 10 LCD (125 x 45 mm) - 5 digit Sine, triangle, square & logic+TTL · 100 MHz 202-203 ARBITRARY FUNCTION GENERATORS GX320 1 20 · · · · · · SPECIFICATIONS SPECIFICATIONS Number of channels Max. frequency (MHz) Display Signal waveforms Sweep Modulation AM/FM FSK/ASK function BURST function GATE function MASTER/SLAVE function Frequency meter Arbitrary function SX-GENE software EasyWave software Pages GX1025 2 25 · · · · · · · GX1050 2 50 3.5'' colour TFT Sine, triangle, square, ramp, pulse, white noise, Arb · · · · · DOX3104 - DOX3304 1 25 8'' 204-205 200 MHz · · · · 184-185 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3201 TEST & MEASUREMENT > LOW FREQUENCY GENERATORS > DDS FUNCTION GENERATORS GX305, GX310 & GX320 Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology Multi-function, stand-alone, innovative laboratory generators/meters! Ergonomics: uniquely easy to read! The GX generators have a large LCD screen (125 x 45 mm) offering exceptionally easy reading thanks to the main display's 5 digits 20 mm high. In addition, the GX generators can simultaneously display all the parameter settings (Vdc, Vrms or Vpp, waveform, etc.). STRENGTHS · Frequency range from 0.001 Hz to 10 MHz (GX310) or 20 MHz (GX320) · DDS technology with a frequency accuracy of +/-20 ppm · Adjustment of stable frequency to the nearest digit · "Logic signal" function for direct adjustment of the high and low levels (TTL, CMOS, etc.) · 100 MHz frequency meter, 300V CAT I · Versions programmable via USB link with the standard SCPI protocol · AM/FM modulation (GX320) · GATE, BURST, FSK and PSK functions (GX320) · Storage of 15 complete instrument configurations (GX320) Specific innovative function: Adjustable-phase synchronisation of several generators in a cascade arrangement (GX320). Synchronization of several generators in a cascade arrangement The "SYNC" function on the GX 320 allows several generators to be set up in a cascade arrangement to make a variable-phase multiple-signal generator. A first GX 320, used as the "Master", provides the other "Slave" instruments with the clock used to generate the signals. It also supplies the synchronizing pulse to start all the instruments simultaneously. In this way, the phase shift of each signal is controlled. GX 320 Master GX 320 Slave 1 GX 320 Slave 2 Example 1: simulation of a three-phase signal Channel 1: master (0°) Channel 2: slave1 (120°) Channel 3: slave2 (-120°) Example 2: Fourier synthesis Synchronization of the generators (3 in this example) allows simulated synthesis of a square signal from its primary harmonics. 202 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com TEST & MEASUREMENT > LOW FREQUENCY GENERATORS > DDS FUNCTION GENERATORS SPECIFICATIONS SPECIFICATIONS Human-machine interface Display Adjustment of signal parameters BNC output terminals on front panel BNC input terminals on front panel Continuous signal generation Frequency Resolution / accuracy Amplitude Accuracy of level (Flatness) Signal waveforms Frequency sweep Modes INT internal sweep EXT external sweep Modulation Internal AM modulation External AM modulation Internal FM modulation External FM modulation SHIFT K function Burst function Internal BURST External BURST GATE function Synchro function Cascade configuration of several GX 320s External frequency meter Measurement range / accuracy Safety / max. admissible voltage General specifications Configuration memories Communication interface Mains power supply Safety / EMC Mechanical specifications Warranty GX305 / GX310 GX320 LCD (125 x 45 mm) Adjustable brightness Frequency display with 5 digits 20 mm high Continuous adjustment by encoder, auto-ranging for Frequency and Level, selection of increment digit (F, P, N, etc.) TTL & Sweep Out outputs TTL, Sweep, Clock and Synchro outputs VCF In input VCG, Gate, Clock and Synchro inputs 0.001 Hz to 10.000 MHz (9 ranges - GX 305) 0.001 Hz to 10.000 MHz (10 ranges - GX 310) 0.001 Hz to 20.000 MHz (11 ranges) 5-digit display resolution from 1 mHz to 1 kHz depending on range / 10 kHz, ± 30 ppm for F < 10 kHz 1 mV to 20.0 Vpp with open circuit in 3 automatic ranges 3-digit display Vpp or Vrms Max. resolution 1 mV << 5 % for 1 mHz < F < 10 MHz , and ± 0.5 dB typ. up to 20 MHz (GX 320) (specs for a level from 0.1 Vpp to 20 Vpp) Sine / Triangle (max. frequency 2 MHz) / Square & "LOGIC" / TTL output LIN (linear) or LOG (logarithmic) "Sawtooth" or "Triangle" mode Unlimited span between "F Start" & "F Stop" Sweep time adjustable from 10 ms to 100 s Sweep by signal < 15 kHz, amplitude ± 10 V Modulation by a 1 kHz sine signal Modulation rate 20 % or 80 % Modulation by a signal < 5 kHz, with amplitude ± 10 V for 0 to 100 % modulation (VCG IN) Modulation by a 1 kHz sine signal Unlimited span between "F Start" & "F Stop" Modulation by a signal < 15 kHz Amplitude ± 10 V (VCG IN) Frequency hop, internal or external phase jump 1 to 65,535 pulses Period of pulse trains 10 ms to 100 s 1 to 65,535 pulses Synchro/Period by a TTL signal with frequency < 1 MHz (VCG IN) Validation of AC component from "Main Out" by a TTL signal with frequency < 2 MHz (GATE IN) Maximum frequency of generated signals 100 kHz Adjustment of phase shift to ± 180° (resolution 1°) 5 Hz to 100 MHz / ±0.05 % + 1 digit 300 V CAT I / 300 Vrms Storage/Recall of 15 complete instrument configurations "USB A/B" link for the programmable versions (P) and Ethernet for the GX 320-E 230 V ± 10 % (or 115 V ± 10 %) 50/60 Hz 20 VA max. Removable lead Safety as per IEC 61010-1 (2001) EMC as per EN 61326-1 (2004) 227 (L) x 116 (H) x 180 (W) mm / weight 2.8 kg 3 years CONTENTS ACCESSORIES Set of 2 BNC-BNC cables 1 m long Set of 2 BNC-banana adapters See page 212 HX0106 HX0107 Standard versions 1 function generator, 1 mains power cable, 1 CD-Rom containing: 1 user's manual in 5 languages, 1 programming manual in FR + EN, LabWindows CVI / LabView drivers Programmable versions -P version: 1 function generator, 1 mains power cable, 1 CD-Rom containing: 1 user's manual in 5 languages, 1 programming manual in FR + EN, LabWindows CVI / LabView drivers, 1 USB A/B cable - Ethernet version -E version: The same + 1 Ethernet cable TO ORDER 5 MHz function generator 10 MHz function generator Programmable 10 MHz function generator 20 MHz function generator Programmable 20 MHz function generator GX305 GX310 GX310-P GX320 GX320-E TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3203 TEST & MEASUREMENT > ARBITRARY FUNCTION GENERATORS > DDS FUNCTION GENERATORS GX1025 & GX1050 GX 1025, 25 MHz Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology These multi-function, communicating laboratory generatorsmeters with built-in frequency meter are ideal for all R&D lab, testing and production applications, as well as for technical training and higher education. STRENGTHS · Large 320 x 240 mm TFT LCD screen with high contrast for better visibility, intuitive front panel and simple use · DDS technology on 2 outputs for coupling or duplication · Generation of standard signals such as sine, square and triangle, as well as more complex signals: pulse, ramp or white noise · Generation of arbitrary signals which are precise, stable and pure, with low distortion at a sampling rate of 125 MS/s on 14- bit resolution · Internal SWEEP wobble modulation: external or manual, linear or logarithmic · The integrated AM, FM, PM, ASK and FSK modulation functions can be used to generate modulated signals very easily without an independent modulation source · Memory depth of up to 16 kpoints, allowing reconstruction or simulation of any type of complex signal · Generator user interface and integrated help in English · USB interface on front panel for data storage · USB interface on front panel for programming and control of the instrument via the SX-GENE software GX 1050, 50 MHz SX-GENE v2.0 can be used to control a GX 1025 or GX 1050 arbitrary function generator, save and recall configurations and generate arbitrary signals. STRENGTHS It allows: · Data transfer in .arb files (from the generator to the PC) · Recovery of a signal from a METRIX® oscilloscope curve (.trc file transferred into the generator) · Configuration of the generator (.cfg) · Recovery of an arbitrary signal stored in one of the generator's 10 memory locations GX 1050 (rear view) CONTENTS 1 GX delivered with 1 mains power cable, 1 USB cable, 1 user manual, 1 programming manual on CD-Rom and the SX-GENE v2.0 software 2042 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com TEST & MEASUREMENT > ARBITRARY FUNCTION GENERATORS > DDS FUNCTION GENERATORS SPECIFICATIONS SPECIFICATIONS Human-machine interface Display Front panel commands Adjustment of signal parameters BNC output terminals on front panel BNC I/O terminals on rear panel Continuous signal generation Signal types Arbitrary signal generation Resolution / sampling Data storage Signal editing with SX-GENE Signal frequency Frequency range Resolution / accuracy Long-term drift Temperature coefficient Amplitude Voltage level Level accuracy (Flatness) Vd c offset Impedance / protection Signal characteristics Sine Triangle (max. frequency 2 MHz) Square & &pulse Modulations (internal or external source) AM modulation FM modulation FSK modulation ASK modulation PM modulation Other functions Sweep Burst External frequency meter Measurement range / resolution Sensitivity / input impedance General specifications Data storage Communication interface Software Mains power supply Mechanical specifications Warranty ACCESSORIES See page 217 GX1025 GX1050 Large high-contrast 3.5 `' TFT colour screen / Resolution 320 x 240 18 direct-access buttons, 1 rotary button Continuous adjustment by the encoder and/or numeric keypad Generator outputs 1 & 2 - Separate adjustment (waveform, f, phase, amplitude, etc.), coupled or duplicated TTL-compatible trigger and synchronization outputs Sine, Square, Triangle, Ramp, Pulse, White Noise, Arbitrary Signal (48 pre-installed waveforms) 14 bits / 125 MS/s 16k memory depth (512k on CH1 only) - Storage of predefined or specific signals on USB key Acquisition, transfer & modification of a signal acquired from an oscilloscope (OX6000, OX7000, SCOPEin@BOX) Graphical or mathematical editing with the SX-GENE software Sine from 0.001 mHz to 25.000 MHz Triangle 300 kHz, Noise and Square 25 MHz, Pulse 10 MHz, Arbitrary Signals 5 MHz Sine from 0.001 mHz to 50.000 MHz, Triangle 300 kHz, Noise and Square 50 MHz, Pulse 20 MHz , Arbitrary Signals 5 MHz 7-digit display resolution from 1 mHz to 1 kHz depending on frequency range ± 20 ppm for F > 10 kHz , ± 30 ppm for F < 10 kHz ±100 ppm / year < 5 ppm / °C Output 1 = 2 mVpp ~ 10 Vpp 50 2 mVpp ~ 20 Vpp (open circuit) Output 2 = 2 mVpp ~ 3 Vpp 50 2 mVpp ~ 6 Vpp (open circuit) < 0.1 dB for f < 100 kHz Output 1 = ±10 Vdc (open circuit), Output 2 = ±3 Vdc (open circuit) Accuracy ±1 % ±1 mV 50 / Protection against short-circuits Distortion < 0.2 % typical for f < 20 kHz, and harmonics < -50 dBc for DC < f < 25 MHz (level < 1 Vpp) Linearity error < 1 % max. Rise time < 12 ns (typ.) Duty cycle 20-80% (DC < f < 20 MHz) Pulse 20 ns to 2,000 s Carrier: Sine, Square, Triangle, Arbitrary (except DC) modulation Modulated signals: Sine, Square, Ramp, Noise, Arbitrary (2 mHz-20 kHz) Modulation depth: 0% to 120% Carrier: Sine, Square, Triangle, Arbitrary (except DC) Modulated signals: Sine, Square, Ramp, Noise, Arbitrary (2 mHz-20 kHz) Modulation depth: 0% to 120% Frequency offset 0 to 12,5 MHz Frequency offset 0 to 25 MHz Carrier: Sine, Square, Triangle, Arbitrary (except DC) Modulated signals: 50% of duty cycle (2 mHz to 50 kHz) Carrier: Sine, Square, Triangle, Arbitrary (except DC) Modulated signals: 50% of duty cycle (2 mHz to 50 kHz) P Carrier: Sine, Square, Triangle, Arbitrary (except DC) Modulated signals: Sine, Square, Ramp, Triangle, Noise, Arbitrary (2 mHz-20 kHz) Phase shift: 0 to 360° Carrier: Sine, Square, Ramp, Triangle, Arbitrary (except DC) - Type: Linear/Logarithmic Direction: Increasing or Decreasing - Sweep time: 1 ms to 500 s - Trigger: Manual, External, Internal Signals: Sine, Square, Ramp, Arbitrary (except DC) - Type: Short (1-50,000 cycles), Infinite, Gate - Phase start/stop: -180° to +180° - Internal period: 1 s to 500 s ± 1% 100 mHz to 200 MHz 20 mVrms for 100 mHz<f<100 MHz, 40 mVrms beyond / 1 M Storage of predefined or specific signals and complete instrument configurations on USB key USB Device, USB host The SX-GENE software can be downloaded free of charge from our support website, along with the LV and LW drivers 100~240 Vacrms 45~440 Hz CAT II - < 30 W 229 x 105 x 281 mm 2.8 kg 2 years TO ORDER 25 MHz arbitrary function generator 50 MHz arbitrary function generator GX1025 GX1050 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3205 TEST & MEASUREMENT > LABORATORY POWER SUPPLIES AX501, AX502, AX503 & AX503F Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology As well as being particularly rugged, these power supplies are also lightweight, economical and based on the latest technology! The AX 501, AX 502 and AX 503 laboratory power supplies with 1, 2 or 3 outputs offer electronic limitation of the current in the event of short-circuit and temperature control in the event of overload or overheating. Their linear technology is based on a toroidal transformer which halves their weight and improves their efficiency. STRENGTHS · Linear technology: stability, low noise, good response to current demand · Active protection against short-circuits, overloads and overheating · Outputs with double insulation in relation to the mains · Series or parallel output coupling for generating up to 60 V / 2.5 A or 30 V / 5 A · Coupling of the two 30 V outputs in "tracking" mode in order to adjust them simultaneously (master/slave) · Adjustable current limitation on the 30V outputs · A third adjustable 2.7 V-5.5 V/5 A output on the AX 503 can be used to power logic circuits (TTL/ CMOS) · Compact and lightweight · Dual-well safety terminals · An earth terminal with reversed polarity to avoid connection errors SPECIFICATIONS SPECIFICATIONS Technology Display Outputs Coupling of outputs Output tracking Special features Power supply Dimensions (H x L x W) Weight Warranty AX501 1 x (30V/2.5A) 4kg AX502 AX503 Linear LEDs green and red- 3 digits 2 x (30V/2.5A) 2 x (30 V/2.5 A) 1 x (2.7 to 5.5 V/5 A) Series or parallel Yes ("track" mode) Electronic protection against short-circuits, overloads and overheating. Output double insulated from mains Toroidal transformers (no forced ventilation and low emissions) Double-well safety terminals 115 V* / 230 V 120 x 225 x 270 mm 4.5kg 6kg 3 years AX503F 2 x (30 Vdc/ 2.5 A fixed 3.3 Vdc fixed/5 A fixed SPECIFIC ACCESSORIES Reverse-polarity earthing cable (green/yellow) "STANDARD" CONTENTS 1 AX, 1 power cable, 1 user's manual P01295073A ACCESSORIES See page 211 TO ORDER AX 501 AX 502 AX 503 AX 503F 2062 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com AX0501A AX0502A AX0503A AX0503F TEST & MEASUREMENT > LABORATORY POWER SUPPLIES > PROGRAMMABLE POWER SUPPLY AX1360-P Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology Performance and simplicity at the best price! STRENGTHS · 2 adjustable outputs (0-30 V) and 1 selectable fixed output (2.5 V / 3.3 V / 5 V) · Bright colour display of the currents and voltages simultaneously on 3 digits · Simplified use thanks to serial or parallel coupling without leads · Quicker setup with 4 configurations available for recall on the front panel · High stability and low drift over time, whatever the mode · Protection against voltage surges, overheating and short-circuits · Ventilation control according to the output power · USB communication SPECIFICATIONS SPECIFICATIONS Frequency Display Number of outputs Voltage control Output 1 Output 2 Output 3 Current control Output 1 Output 2 Output 3 Accuracy Voltage Current Resolution Voltage Current Ripple and noise Voltage Temperature coefficient Voltage On-load Voltage control Current control Protection Short-circuits Overcurrent "SAVE/RECALL" function Number of stored configurations Technical specifications Current and voltage adjustment Interface / software Mains power supply Safety / protection Mechanical specifications Warranty AX 1360-P Digital with LEDs Simultaneous voltage and current in colour 3 Independent 3 A 3 A 3 A 0 30 V 0 30 V 2.5 V / 3.3 V / 5 V Parallel 6 A 6 A - ±(0.5 % of reading + 2 digits) ±(0.5 % of reading + 5 digits) 10 mV (0 to 9.99 V) 100 mV (10 to 30 V) 10 mA < 1 mVrms < 300 ppm / °C Independent and in parallel < 0.1 % +5 mV < 0.2 % +3 mA Current limitation and visual indication by red LED Fuse 4 Outputs 1 and 2 by potentiometers, Output 3 by switch USB / LV and LW drivers 220 V / 50 Hz 60 Hz Dimensions : 310 x 250 x 150 mm / weight: 7.5 kg 4 2 years "STANDARD" CONTENTS AX1360-P: 1 programmable power supply, 1 power cable, 1 USB cable, 1 CD-Rom containing the user's manual and the LabView drivers ACCESSORIES See page 217 TO ORDER AX 1360P programmable power supply AX1360-P TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3207 TEST & MEASUREMENT > LABORATORY CALIBRATORS > MULTIFUNCTION CALIBRATORS CX 1651 & CX 1652 VA CX 1652 for simple checking of a current clamp. Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology Designed for calibrating measuring instruments, the calibrators from Metrix are particularly accurate and stable. STRENGTHS Based on a new concept, they generate: · standard electrical parameters for temperature or energy applications · non-harmonic signals for testing equipment when the distortion on the input signals is non-null. Ils permettent la calibration de multiples instruments : · Multimeters · Analogue instruments · Switchboard equipment · Current clamps · Portable calibrators · Wattmeters · Electrometers · Oscilloscopes · Thermometers · Loggers, etc. 2082 Calibrate your current sensors, temperature sensors, etc. TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com TEST & MEASUREMENT > LABORATORY CALIBRATORS > MULTIFUNCTION CALIBRATORS SPECIFICATIONS SPECIFICATIONS Voltage Current Resistance Capacitance Frequency Power Energy Temperature DC AC DC AC 4-wire configuration Square wave, duty cycle and amplitude calibrated Thermocouple Resistance sensor 6 ranges from 0 to 1,000 V 6 ranges from 0 to 1,000 V 6 ranges from 0 to 20 A (CX1651) 6 ranges from 0 to 30 A (CX1652) 6 ranges from 0 to 20 A (CX1651) 6 ranges from 0 to 30 A (CX1652) 10 ranges from 0 to 50 M (CX1651) 16 ranges from 0 to 1G (CX1652) 9 ranges from 0.9 nF to 50 F (CX1651) 10 ranges from 0.7 nF to 100 F (CX1652) 0.1 Hz to 20 MHz 0.0004 to 2.4 kVA (CX1651) 0.0004 to 4.8 kVA (CX1652) K, N, R, S, B, J, T, E from -250 to +1,820 °C Pt100, Pt200, Pt1000, Ni100 from -200 °C to 850 °C * Depending on measurement range. Please refer to the user's manual for further details. MULTIMETER Function Vd c (DC voltage) mVd c (DC voltage) mAd c (DC current) FREQ (Frequency) R4W (Resistance) TRTD (RTD sensors) TTC (TC sensors) SGS (Deformation) * Measurement current 1 mA. CX1651 Range 0 - ±12 V Accuracy 0.01 % + 300 V 0 - ±2,000 mV 0.2 % + 7 V 0 - ±25 mA 0.02 % + 1 A 1 Hz 15 kHz 0.005 % 0 - 2 k 0.02 % + 100 m -150 °C +600 °C 0.1 °C -250 °C +1,820 °C 0.4 to 2.5 °C Depending on sensor 0.01 % + 10 V + sensor accuracy CX1651 CX1652 Best accuracy* 0.003 %R + 16 V 0.0015 %R + 8 V 0.025 %R + 100 V 0.018 %R + 100 V 0.01 %R + 60 A 0.01 %R + 0.6 A 0.05 %R + 100 A 0.05 %R + 1 A 0.015 %R 0.01 %R 0.5 %R 0.5 %R 0.005 %R 0.005 %R Depends on the voltage, current and time values The best uncertainty is 0.016 % for DC and 0.07 % for AC 0,4 °C 0,4 °C 0,1 °C 0,1 °C CX1652 Range 0 to ±20 V Accuracy 0.01 % + 500 V 0 to ±2 V 0.02 % + 7 V 0 to ±25 mA 0.015 % + 300 nA 1 Hz to 15 kHz 0.005 % 0 to 2.5 k 0.02 % + 10 m -200 to +850 °C* 0.1 °C -250 to +1,820 °C 0.4 to 2.5 °C "STANDARD" CONTENTS CX1651 : 1 multifunction calibrator delivered with 1,000 V / 20 A test cables (x 2), 1 Option 40 cable adapter (Canon 25/2 x banana cable adapter, 1 m), 1 Option 60 cable adapter (Canon 25/4 x banana cable adapter, 1 m), 1 Option 70 cable adapter (adapter for resistances on four terminals), 1 RS 232 cable, 1 power cable, 2 spare fuses, 1 test report and 1 user's manual. CX1652 : 1 multifunction calibrator delivered with 1 mains power cable, 1 user's manual (CD), 2 x red/black 1,000 V / 20 A test cables 1 m long, 1 SUB-D25 / 2 x banana adapter cable 1 m long (DC voltage/current), 1 SUB-D25 / 4 x banana adapter cable 1 m long (4-wire resistance), 1 SUB-D25 / 4 x banana adapter cable 1 m long (4-wire resistance simulation), SUB-D25 / 2 x banana adapter cable 1 m long (mVdc and TC), spare fuse(s), 1 RS232 cable 1 m long, 1 test report. ACCESSORIES See page 217 TO ORDER CX 1651 multifunction calibrator CX 1652 multifunction calibrator TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com CX1651 CX1652 3209 TEST & MEASUREMENT > TRAINING EQUIPMENT, BOXES & SHUNTS > TRAINING BOXES AND SHUNTS TRAINING BOXES AND SHUNTS Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · IEC61010-1 -150V CAT II, 50V CAT III · Selection by rotary switch Simple resistance boxes P03197521A P03197522A P03197523A P03197524A P03197525A P03197526A P03197527A P03197528A 4, 5 and 7-decade resistance boxes P01197401 P01197402 P01197404 Coupling jumpers P01101892A 0,1 to 1 1 to 10 10 to 100 100 to 1,000 1 to 10k 10 to 100k 100 to 1,000k 1 to 10M BR 04: 4 decades, 1 to 10 k BR 05: 5 decades, 1 to10 k BR 07: 7 decades, 1 to10 k 19 mm spacing - Ø 4 mm - 36 A Inductance box P01197451 BL 07: 7 decades, 1 H to 10 H Measurement shunts HA030-1 (class 0.5 as per IEC 61010-1 600 V CAT III) Max. current 30 A Voltage drop 300mV 2102 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com TEST & MEASUREMENT > ACCESSORIES FOR OSCILLOSCOPES > CHOOSE YOUR PROBE CHOOSE YOUR VOLTAGE PROBE There are multiple criteria for choosing a probe. The approach below helps to specify your requirements and guide you naturally towards the most suitable model for your application. To choose the probe to adapt to your oscilloscope, we advise you to follow the logic below: Measurement input · Max. AC voltage measurement and choice of installation category: CAT II or III? Attenuating probe or differential probe? · Choice of attenuation: 1/10, 1/100 or 1/1,000 or 1/20, 1/200? Bandwidth according to the oscilloscope? · Measurement input impedance Output Connections · BNC or PROBIX? Specific features · What are your other criteria? Capacitance, rise time, safety, power supply, etc.? SPECIFICATIONS CAT II voltage probes High-voltage probe CAT II 300V voltage probes PROBIX probes for SCOPIX Differential probes Pages Voltage probes · · · · · 212 213 213 192 214 CHOOSE YOUR ISOLATED CURRENT PROBE Measurement with AC/DC clamp Measurement with AC clamp Measurement with flexible AC clamp Pages Current probes · · · 216 215 215 BNC Protection and transport Fuses Pages Connection and protection accessories · · · 217 218 219 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3211 TEST & MEASUREMENT > ACCESSORIES FOR OSCILLOSCOPES > ELECTRONIC VOLTAGE PROBES HX0003, HX0004, HX0005, HX0006 & HX0108 STRENGTHS · A family of 5 products to cover all types of requirements · Attenuation ratio of 10 or 100 (depending on the model) · Bandwidth from 150 MHz to 300 MHz · EN61010 safety from 400 V CAT II to 1,000 V CAT III (depending on the model) · Compensation range from 12 to 22 pF or from 12 to 25 pF (depending on the model) · Connection accessories are available for the probes: - HX0007: hook-type wire-grip termination - HX0008: crocodile-type wire-grip termination · Additional accessories are delivered with the HANDSCOPE HX0108 kit · ISOPROBE III probe compliant with 600 V CAT III with 1/10 attenuation on a 500 MHz bandwidth + HX0107 BNC /BAN adapter SPECIFICATIONS Attenuation Bandwidth Input impedance (M) Capacitance (pF) Rise time (ns) EN61010-2-031 safety Compensation range (pF) Retractable safety sleeve HX0003 1:10 150 10 ±1 % 14 1,2 400 V CAT II 12 to 25 Grey HX0004 1:10 250 10 ±1 % 14 1,2 1000 V CAT II 12 to 25 Blue HX0005 1:10 450 10 ±1 % < 14 1 1000 V CAT II 12 to 25 Violet HX0006 1:100 300 100 ±1 % 6 < 1 1000 V CAT II 12 to 22 Red HX0108 1:10 500 10 ±1 % 12 0,9 600 V CAT III 10 to 22 Grey HX0108 kit "STANDARD" CONTENTS HXxxxx: 1 probe, 1 reference cable, 1 user's manual ACCESSORIES (FOR HX000X) Hook-type wire-grip termination Crocodile wire-grip termination HX0007 HX0008 TO ORDER Compact probe, 10:1, 150 MHz HX0003 Compact probe, 10:1, 250 MHz HX0004 Compact probe, 10:1, 450 MHz HX0005 Compact probe, 100:1, 300 MHz HX0006 Measurement kit comprising one compact 10:1 probe, 500 MHz 600 V CAT III, and one BNC/Banana ø 4 mm adapter (HX0107) HX0108 212 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com TEST & MEASUREMENT > ACCESSORIES FOR OSCILLOSCOPES > GENERAL-PURPOSE HIGH-VOLTAGE / HIGH-FREQUENCY PROBES HX0027 STRENGTHS · Design mounted on a patented ceramic support, with the elements adjusted by laser · Interchangeable spring-mounted tip · 1/1,000 probe with 30 MHz bandwidth · This 14kV high-voltage probe can be used in various Category II sectors HX0206, HX0210 & HX0220 Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology STRENGTHS · A family of 3 products to meet the various requirements · A switchable attenuation of 1: 1 or 10: 1 · Bandwidth from 60 MHz, 100 MHz or 200 MHz depending on the model SPECIFICATIONS Attenuation Bandwidth Input impedance (M) Capacitance (pF) Rise time (ns) EN61010-2-031 safety Compensation range (pF) HX0027 1 :1000 30 100+-1 % < 2.5 < 12 14 kV max 40 kVpeak 10 to 50 HX0206 1 :1 1 :10 15 60 1 10 45 15 23 6 300 V CAT II 300 V CAT II - 10 to 50 HX0210 1 :1 1 :10 15 100 1 10 46 15 23 3.5 300 V CAT II 300 V CAT II - 10 to 50 HX0220 1 :1 1 :10 15 200 1 10 45 11 35 1.7 300 V CAT II 300 V CAT II - 10 to 35 "STANDARD" CONTENTS HX0027: 1 probe, 1 "hook" measurement termination, 1 crocodile clip, 1 screwdriver for adjustment, 1 user's manual, 1 hard case HX0206-HX0210-HX0220: 1 probe, 1 "hook" measurement termination, 1 crocodile measurement earth, 1 screwdriver for adjustment, 1 user's manual TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3213 TEST & MEASUREMENT > ACCESSORIES FOR OSCILLOSCOPES > DIFFERENTIAL VOLTAGE PROBES MX9030, MTX1032-B & MTX1032-C Diagnostic & control Education Energy efficiency Transport Tertiary & residential Industries Generation, transmission & distribution Laboratory & metrology Ideal accessories for analogue or digital oscilloscopes for viewing signals not referenced to the earth, the MTX 1032-B and MTX 1032-C are equipped with 2 differential channels. Powered by the mains supply, these probes can be used separately or hooked up to MTX Compact oscilloscopes. The MX 9030 probe is supplied in a stand-alone handheld casing powered by a battery. SPECIFICATIONS Differential input voltage Max. common-mode voltage Attenuation / accuracy Bandwidth Rise time Output impedance Coaxial output voltage (max.) Noise level General specifications Power supply Safety Dimensions / weight MX 9030-Z ±60V or ±600V 1/20 and 1/200 / ±3 % 30 MHz 11.7 ns ±3 V with 1 M load 9 V battery IEC 61010-1 600V CAT IV 163 x 62 x 40 mm / 195 g (with battery) STRENGTHS · A family of 3 products to meet the various requirements · 1 or 2 input channels, 30 MHz or 50 MHz bandwidth · Extra-long banana or coaxial/banana measurement leads · Supplied in a laboratory casing or handheld casing with wrist-strap MX 1032-B ±600 V 30MHz 11.7ns 50 < 10 mVpp ±40V or ±400V 1/10 and 1/100 / ±3 % ±4 V with 1 M load HX0210 50MHz 7ns Mains: 230 Vac ±10 % 50/60 Hz IEC 61010-1 600V CAT III IEC 61010-1 600V CAT II 270 x 250 x 63mm / 1.2kg "STANDARD" CONTENTS MX9030-Z: 1 single-channel probe with output on BNC cable, 1 standard battery installed, 1 set of PVC banana leads 1.10 m long, 1 set of 2 industrial-grade crocodile clips, 1 user's manual MTX1032-B: 1 x 2-channel probe in "MTX Pack" casing, 2 BNC cables 20 cm long, 2 sets of PVC banana leads 1.10 m long, 1 European mains power cable, 1 set of accessories for mounting the probe on the oscilloscope, 1 user's manual MTX1032-C: 1 x 2-channel probe in "MTX Pack" casing, 2 BNC cables 20 cm long, 1 set of 2 BNC-banana cables 2 m long, 2 crocodile wire-grips for probes, 1 European mains power cable, 1 set of accessories for mounting the probe on the oscilloscope, 1 user's manual ACCESSORIES See page 217 TO ORDER 1 x 30 MHz stand-alone differential probe x 30 MHz differential probe with banana inputs 2 x 50 MHz differential probe with coaxial inputs 2142 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com MX9030-Z MTX1032-B MTX1032-C TEST & MEASUREMENT > ACCESSORIES FOR OSCILLOSCOPES > ISOLATED CURRENT PROBES AC CURRENT PROBES SPECIFICATIONS Measurement range Transformation ratio Bandwidth Accuracy Clamping diameter Output connector Cable length Dimensions Weight IEC 61010-2-32 safety Accessories supplied To order MN 60 0.1 to 60 Apeak AC and 0.5 to 600 Apeak AC 100 mV - 10 mV/A 40 Hz to 40 kHz 2 % and 1.5 % 20 mm BNC 2 m 135 x 51 x 30 mm 180 g P01120409 FLEXIBLE CURRENT PROBES Y7N 1 A to 1,200 Apeak 1 mV / A C160 D38N 0.1 to 2,000 Apeak 1 A to 5,000 Apeak 100 mV/A 10 mV/A 1 mV/A 10 mV/A 1 mV/A -0.1 mV/A 5 Hz to 10 kHz 10 Hz to 100 kHz 2 % 3 %, 2 %, 1 % 30 mm 52 mm BNC BNC 2 m 2 m 195 x 66 x 34 mm 216 x 111 x 45 mm 420 g 550 g 300 V CAT IV / 600 V CAT III 1 user's manual P01120075 P01120308 30 Hz to 50 kHz 2 % 64 mm BNC 2 m 305 x 120 x 48 mm 1 200 g P01120057A SPECIFICATIONS Measurement range Transformation ratio Bandwidth Accuracy Clamping diameter Output connector Cable length Dimensions Weight Power supply IEC 61010-2-32 safety Accessories supplied To order Câble Ø = 30 mm maxi Barre 63 x 5 mm max. 2 câbles Ø = 25 mm maxi I 195 mm Y7N clamp 66 mm 34 mm MA200 30-300/3 - (17 CM) 0.5 to 45 Apeak 0.5 to 450 Apeak 100 mV/A - 10 mV/A 5 Hz to 1 MHz 1 % + 0.3 A 45 mm BNC 2 m + 40 cm 140 x 64 x 28 mm 200 g 1 x 9 V 600 V CAT IV 1000 V CAT III P01120570 MA200 30-300/3 - (25 CM) 0.5 to 45 Apeak 0.5 to 450 Apeak 100 mV/A - 10 mV/A 5 Hz to 1 MHz 1 % + 0.3 A 70 mm BNC 2 m + 40 cm 140 x 64 x 28 mm 200 g 1 x 9 V 600 V CAT IV 1000 V CAT III 9 V battery and user's manual P01120571 ACCESSORIES Mains adapter for MA200 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com MA200 3000/3 - (35 CM) 5 A to 4500 Apeak 1 mV/A 2 Hz to 1 MHz 1 % + 0.3 A 100 mm BNC 2 m + 40 cm 140 x 64 x 28 mm 200 g 1 x 9 V 600 V CAT IV 1000 V CAT III P01120572 P01102087 3215 TEST & MEASUREMENT > ACCESSORIES FOR OSCILLOSCOPES > AC/DC CURRENT PROBES AC/DC CURRENT PROBES SPECIFICATIONS Measurement range Transformation ratio Bandwidth Accuracy RMS analogue output Clamping diameter Output connector Cable length Dimensions Weight Power supply IEC 61010-2-32 safety Accessories supplied To order HX0102 3 mA to 20 Aac/dc 100 mV/A DC to 60 kHz < 1.5 % 30 mA to 20 Aac/dc 100 mVdc/A 11.8 mm BNC 2 m 231 x 67 x 36 mm 330 g 1 x 9 V HX0102 HX0102-K* E27 100 mA to 100 Aac/dc 100 mV/A - 10 mV/A DC to 100 kHz 3 % - 4% PAC17 500 mA to 40 Aac/60 Adc 500 mA to 400 Aac /600 Adc 1 A / 10 mV - 1 A / 1 mV DC to 30 kHz 1.5 % - 2 % PAC27 500 mA to 100 Aac/140Adc 500 mA to 1,000 Aac/1,400 Adc 1 A / 10 mV - 1 A / 1 mV DC to 30 kHz 1.5 % - 4 % - - - 11.8 mm BNC 2 m 1 cable Ø 30 mm 2 cables Ø 24 mm BNC 2 m 1 cable Ø 39 mm 2 cables Ø 25 mm 2 busbars 50 x5 mm BNC 2 m 231 x 67 x 36 mm 224 x 97 x 44 mm 236,5 x 97 x 44 mm 330 g 440 g 1 x 9 V 1 x 9 V IEC 61010-2-032 - 300 V CAT IV / 600 V CAT III 9 V battery and user's manual 520 g 1 x 9 V P01120027 P01120117 P01120127 SPECIFICATIONS Measurement range* Transformation ratio Bandwidth Switchable low-pass filters 10 to 90% rise time Clamping diameter Output connector Cable length Dimensions Weight Power supply Safety Accessories supplied *Frequency derating from 60 kHz MH60 10 mA to 100 Arms or DC (140 Apeak) 10 mV/A 1 MHz None / 30 kHz / 3 kHz 350 ns 1 cable Ø 26 mm BNC 2 m 138 x 49 x 28 mm Approx. 200 g (with cable and rechargeable battery) Internal NiMh rechargeable battery (approx. battery life 8 hrs) or external 5 Vdc power supply via USB type B female connection IEC 61010-1, IEC 61010-2-032, 300 V CAT III / 600 V CAT II P01120612 "STANDARD" CONTENTS MH60 isolated AC and DC current probe for oscilloscopes, delivered with 1 100V240 V 50/60 Hz mains adapter, 1 USB / USB power cable, 1 user's manual in 5 languages ACCESSORIES Mains adapter for E27, MH60, PAC17, PAC27 P01651023 1 x 110/240V 50/60 Hz mains power pack with female USB type A 5V 1A + 1 charging/connection cable 1.80m long, USB type A male/USB type Micro-B male NiMh rechargeable battery for MH60 P01296049Z 2162 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com TEST & MEASUREMENT > ACCESSORIES FOR OSCILLOSCOPES > ACCESSORIES COAXIAL ACCESSORIES Safety leads with 50 impedance, length 1 m IEC61010-2-031 - 600 V CAT III, black > HX0106 (2 p) Earth safety leads, length 2 m, O 4 mm banana connection IEC 61010-2-031 Cat. III 1,000 V: female banana plug / female, yellow/green (earth) > P01295073A (5 p) Set of 2 adapters Insulated male BNC plug - insulated female plugs (R/B) Ø 4 mm with 19 mm spacing 600 V CAT III > HX0107 Set of 2 adapters Insulated female BNC - Insulated plugs (RIN) ø 4 mm with 19 mm spacing - 600 V CAT III > P01102101Z Set of 2 adapters Male BNC -insulated female sockets (R/B) Ø 4 mm with 19 mm spacing 500 V CAT I, 150 V CAT III > P01101846 Set of 2 adapters Male BNC -insulated male sockets (R/B) Ø 4 mm with 19 mm spacing 500 V CAT I, 150 V CAT III > P01101847 Load adapter 50 BNC additional load > PA4119-50 (1 p) Safety coupling jumper with 19 mm spacing - Ø 4 mm - 36 A IEC 61010-2-031: Set of 10 black coupling jumpers > P01101892A Demonstration board for practical exercises, valid for all our oscilloscopes > HX0074 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3217 TEST & MEASUREMENT > ACCESSORIES FOR OSCILLOSCOPES PROTECTION AND TRANSPORT ACCESSORIES, MECHANICAL ADAPTATIONS MTX-family bag for MTX 3240, MTX 3250, MTX 3252, MTX 3352 and MTX 3354 models. The mouse can be stored in the side pocket. HX0024 Empty hard case for Scopix equipped with precut foam inserts for stowing documents and accessories (power supply, Probix accessories, communication cables, etc.). HX0038 Protective hands-free bag for HANDSCOPE portable oscilloscopes (OX5022B and OX5042B) HX0105 Battery for SCOPIX IV: 5.8AH LI-ION battery pack External charger for LI-ION battery SCOPIX IV bag comprising an all-terrain bag with waterproof bottom and shoulder strap (380x280x200 mm) and an internal compartmented bag for stowing the SCOPIX and its accessories P01296047 P01102130 HX0120 Charger unit for 12 Vdc vehicle cigarette lighter HX0061 2182 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com TEST & MEASUREMENT > ACCESSORIES > FUSE SELECTION TABLE FUSE SELECTION TABLE Product concerned MX0044HD MX0044HDL MX0056C MX0058HD MX0059HD MX0059HDL AX 501 AX 502 AX 503 MTX 3250 MTX 3281 MTX 3282 MTX 3283 MTX203-Z MTX203-Z MTX204-Z MTX204-Z MTX3290 MTX3291 MTX3292B MTX3293B MX 1 MX 1 MX 20 MX 20 MX 20HD MX 20HD MX 22 MX 22 MX 23 MX 24B MX 24B MX 26 MX 26 MX 409 MX 44 MX 44 MX 44HD MX 44HD MX 51 MX 51 MX 52 MX 52 MX 53 MX 53 MX 54C MX 54C MX 553 MX 556 MX 55C MX 55C MX 56C MX 56C MX 57Ex MX 57Ex MX 58HD MX 58HD MX 59HD MX 59HD MX407 MX5006 MX5060 Standardized dimensions 5 x 20 5 x 20 5 x 20 5 x 20 5 x 20 5 x 20 5 x 20 5 x 20 5 x 20 6 x 32 10 x 38 10 x 38 10 x 38 10X38 6.3x32 10X38 6.3x32 6.3X32 10x38 10X38 10X38 6 x 32 6 x 32 5 x 20 8 x 32 5 x 20 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 6 x 32 5 x 20 6 x 32 5 x 20 6 x 32 5 x 20 8 x 32 5 x 20 8 x 32 5 x 20 6 x 32 5 x 20 6 x 32 6 x 32 6 x 32 5 x 20 6 x 32 5 x 20 6 x 32 5 x 20 6 x 32 10 x 38 5 x 20 10 x 38 5 x 20 6 x 32 6X32 6X32 Amperage 0.630 A 0.630 A 0.630 A 0.630 A 0.630 A 0.630 A 6.3 A 6.3 A 6.3 A 10 A 11 A 11 A 11 A 11A 0.63A 10A 0.63A 10A 11A 11A 11A 10 A 1.6 A 0.63 A 10 A 0.63 A 10 A 10 A 0.63 A 10 A 10 A 0.63 A 10 A 0.63 A 0.200 A 0.63 A 10 A 0.63 A 10 A 0.63 A 10 A 0.63 A 10 A 0.63 A 10 A 0.63 A 10 A 10 A 10 A 0.63 A 10 A 0.63 A 10 A 0.5 A 1 A 11 A 0.63 A 11 A 0.63 A 0.5 A 10A 10A TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com Sales reference AT0096 AT0096 AT0096 AT0096 AT0096 AT0096 AT0087 AT0087 AT0087 AT0095 P01297092 P01297092 P01297092 P01297096 P01297098 P01297096 P01297098 P01297038 P01297092 P01297092 P01297092 AT0070 AT0071 AT0094 AT0055 AT0094 AT0095 AT0095 AT0519 AT0095 AT0095 AT0519 AT0095 AT0519 P01297104 AT0518 AT0095 AT0518 AT0095 AT0094 AT0055 AT0094 AT0055 AT0518 AT0095 AT0518 AT0095 AT0095 AT0095 AT0518 AT0095 AT0518 AT0095 AT0057 AT0064 P01297092 AT0518 P01297092 AT0518 P01297097 AT0095 AT0095 3219 INDEX > BY FUNCTIONS BY FUNCTIONS # 100 mV shunts................................................................ 145 2P/3P earth................................................40 - 42 - 57 to 60 4P earth....................................................................58 to 60 A AC current clamp....................................................139 - 140 AC/DC current clamp....................................................... 141 AC/DC current sensors..................................................... 215 Accessories for oscilloscopes........................................... 192 Air flow rate..................................................................... 123 Air speed.......................................................123 - 126 - 127 Ambient air...................................................................... 128 Ammeter with flexible sensor.............................................. 28 AmpFlex® flexible AC current sensors.............................. 142 Analogue multimeter.......................................................... 22 Audible continuity......................................................17 to 22 B Bag........................................................................154 - 218 Battery charge tester.......................................................... 72 Benchtop digital multimeter.............................................. 170 Benchtop digital oscilloscope...................................182 - 184 Body temperature............................................................ 111 Bus analyser.................................................................... 190 C Cable.............................................................................. 150 Cable and metal conductor locator...................................... 73 Cable detection.................................................................. 73 Capacitance...................................................................... 17 Capacitance boxes........................................................... 145 Clamp multimeter.......................................................30 - 31 CO detector..................................................................... 127 CO2.......................................................................127 - 128 CO2 , temperature & humidity logger................................ 128 Conductivity meter........................................................... 133 Contact thermometer.............................................119 to 121 Continuity of protective earth conductors............................. 43 Continuity tester................................................................. 43 Current.............................................................................. 17 D Data processing software.................................74 - 102 - 130 Db.................................................................................... 22 DDS function generator..........................................202 to 204 Decibel............................................................................ 124 Dew point...............................................................113 - 122 Differential current probe.................................................. 214 Digital insulation tester...............................................51 to 54 Digital multimeter................................. 24 to 26 - 164 to 169 Diode................................................................................ 17 E Earth coupling........................................................... 59 - 60 Earth measurement............................................................ 36 Earth tester................................................................57 to 62 Electric field tester........................................................... 162 Electrical equipment tester......................................... 64 - 65 Electrical installation testing................................ 34 - 40 to 43 Electrical measurement logger.....................................95 - 97 Electrical testing & safety accessories.........................76 to 82 Electronic voltage sensor.................................................. 212 Energy......................................................................88 to 97 Environmental measurement accessories.......................... 136 EV charging station analyser............................................... 44 F Field meter...................................................................... 129 Flexible current sensor..................................................... 215 Flicker.......................................................................88 to 92 Frequency......................................................................... 22 Fuse.......................................................................156 -219 G General-purpose probe.................................................... 213 Graphical digital multimeter................................................ 26 H Hand-cranked installation tester.......................................... 46 Hand-cranked installation tester.......................................... 46 Harmonics................ 27 - 30 - 31 - 40 - 84 to 97 - 147 - 187 High Voltage / High Frequency probe................................. 213 I Inductance boxes............................................................. 145 Installation tester.......................................................40 to 42 Insulation.......................................................... 35 - 46 to 49 Isolated AC current sensors.............................................. 215 L Laboratory power supply.................................................. 206 Laser tight..............................................................117 - 118 Leakage current..........................................48 - 49 - 52 to 55 Leakage current clamp....................................................... 55 LED voltage tester............................................................ 161 Lighting........................................................................... 125 Loop impedance.........................................................40 - 42 Loop resistance..........................................................40 - 42 Luxmeter......................................................................... 125 M Manometer...................................................................... 123 Measurement adapter for 2P+E socket............................... 19 Micro-ohmmeter.........................................................69 - 70 Microwave....................................................................... 148 Microwave training benches............................................. 148 Motor rotation speed........................................87 - 124 - 126 Multifunction calibrator..................................................... 208 N No-contact thermometer.........................................117 - 118 No-contact voltage detection.............................................. 24 O On-site analogue multimeter............................................. 161 On-site electrical safety tester...................................178 -179 On-site insulation tester.............................................51 to 54 Oscilloscope transport...................................................... 218 P pH/Temperature tester..................................................... 131 Phase detection............................................................16-17 Phase rotation...........................................................19 to 20 Phase rotation and/or motor tester...................................... 72 pH-meter......................................................................... 132 Pocket clamp multimeter........................................175 to 177 Portable oscilloscope............................27 - 180 - 187 to 191 Power........ 27 - 30 - 31 - 40 - 64 - 86 to 92 - 95 to 97 - 147 Power & Harmonics training case...................................... 147 Power analyser.................................................................. 87 Power and energy accessories................................103 to 105 Power and harmonics clamp............................................... 87 Process data logger......................................................... 101 Process signal calibrator.................................................. 110 Programmable power supply............................................ 207 Protection...............................................................154 - 218 Pt100............................................................................. 135 Pylon................................................................................. 60 R Radiofrequency & microwave measurements..................... 129 Ratiometer......................................................................... 71 RCD ( tests )...............................................................40 - 42 Resistance.................................................................17 to 26 Resistance boxes............................................................. 145 Resistive probe.......................................................109 - 135 Resistivity..................................................................58 to 62 S Safety of machines............................................................ 37 Safety of portable electrical equipment................................ 37 Safety of switchboards....................................................... 37 SMD tester...................................................................... 162 Soft case......................................................................... 154 Software for multimeters.................................................. 171 Software for oscilloscopes.......................................194 - 195 Solar power....................................................................... 93 Solar power analyser.......................................................... 93 Sound level meter............................................................ 124 Spectrum analyser connected to a PC............................... 198 Stray voltage detection....................................................... 20 Stroboscope.................................................................... 127 T Tachometer..................................................................... 126 Temperature..........................................................109 to 123 Temperature calibrator..................................................... 109 Test adapter for electric vehicle AC charging stations........... 44 Test probe....................................................................... 151 Tester........................................................................ 15 - 17 Thermal camera.............................................................. 111 Thermo-anemometer....................................................... 123 Thermocouple................................................109 - 119 - 134 Thermography................................................................. 146 Thermography training bench........................................... 146 Thermo-hygrometer......................................................... 122 Three-phase network and power analyser....................88 - 91 Total dissolved solids (TDS)............................................... 133 Training case................................................................... 146 Transients..................................................................88 to 92 TRMS current logger..........................................98 - 99 - 101 TRMS voltage logger........................................................ 100 TrueInrush......................................................................... 87 V VD / VAT.....................................................................19 - 20 Voltage Absence Tester (VAT).....................................18 to 20 Voltage detector (VD)..................................................18 to 20 Voltage quality analyser...................................................... 92 2202 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com INDEX > BY PRODUCT BY PRODUCT A A110..................................................... 142 A130..................................................... 142 AX1360-P.............................................. 207 AX501................................................... 220 AX502................................................... 220 AX503................................................... 220 AX503-F................................................ 220 B B102..................................................... 140 BDH R100.............................................. 222 C C100..................................................... 140 C102..................................................... 140 C103..................................................... 140 C106..................................................... 140 C107..................................................... 140 C112..................................................... 140 C113..................................................... 140 C116..................................................... 140 C117..................................................... 140 C122..................................................... 140 C148..................................................... 140 C160..................................................... 140 C173..................................................... 140 CA 10001.............................................. 131 CA 10002.............................................. 131 CA 10101.............................................. 132 CA 10141.............................................. 133 CA 1110................................................ 125 CA 1227................................................ 123 CA 1246................................................ 122 CA 1310................................................ 124 CA 1510................................................ 128 CA 1550................................................ 123 CA 1621................................................ 109 CA 1623................................................ 109 CA 1631................................................ 110 CA 1725................................................ 126 CA 1727................................................ 126 CA 1821................................................ 120 CA 1822................................................ 120 CA 1823................................................ 121 CA 1860................................................ 117 CA 1862................................................ 117 CA 1864................................................ 117 CA 1866................................................ 117 CA 1871................................................ 118 CA 1875................................................ 146 CA 1900................................................ 111 CA 1950................................................ 112 CA 1954................................................ 113 CA 40..................................................... 129 CA 5001.................................................. 22 CA 5003.................................................. 22 CA 5005.................................................. 22 CA 5011.................................................. 22 CA 5231.................................................. 24 CA 5233.................................................. 24 CA 5273.................................................. 25 CA 5275.................................................. 25 CA 5277.................................................. 25 CA 5292.................................................. 26 CA 5292BT.............................................. 26 CA 5293.................................................. 26 CA 5293BT.............................................. 26 CA 6011.................................................. 43 CA 6011 KIT............................................. 43 CA 6113.................................................. 40 CA 6116N................................................ 40 CA 6117.................................................. 40 CA 6131.................................................. 42 CA 6133.................................................. 42 CA 6161.................................................. 64 CA 6163.................................................. 64 CA 6165.................................................. 65 CA 6240.................................................. 69 CA 6255.................................................. 69 CA 6292.................................................. 70 CA 6416.................................................. 62 CA 6417.................................................. 62 CA 6418.................................................. 62 CA 6422.................................................. 57 CA 6424.................................................. 57 CA 6460.................................................. 58 CA 6462.................................................. 58 CA 6470N................................................ 59 CA 6471.................................................. 59 CA 6472.................................................. 60 CA 6474.................................................. 61 CA 6501.................................................. 46 CA 6503.................................................. 46 CA 6505.................................................. 52 CA 6511.................................................. 46 CA 6513.................................................. 46 CA 6522.................................................. 48 CA 6524.................................................. 48 CA 6526.................................................. 48 CA 6528.................................................. 47 CA 6532.................................................. 49 CA 6534.................................................. 49 CA 6536.................................................. 49 CA 6541.................................................. 51 CA 6543.................................................. 51 CA 6545.................................................. 52 CA 6547.................................................. 53 CA 6549.................................................. 53 CA 6550.................................................. 54 CA 6555.................................................. 54 CA 6608.................................................. 72 CA 6609.................................................. 72 CA 6630.................................................. 72 CA 6651.................................................. 44 CA 6681.................................................. 73 CA 6710................................................ 223 CA 702.................................................... 24 CA 7028................................................ 129 CA 703.................................................... 24 CA 732.................................................. 220 CA 742.................................................. 222 CA 742 IP2X........................................... 222 CA 745N.................................................. 17 CA 751.................................................. 152 CA 753 ................................................. 153 CA 755.................................................... 17 CA 757.................................................... 17 CA 762.................................................. 222 CA 762 IP2X........................................... 222 CA 771.................................................. 223 CA 771 IP2X........................................... 223 CA 773.................................................. 223 CA 773 IP2X........................................... 223 CA 8220.................................................. 87 CA 832.................................................. 124 CA 8331.................................................. 88 CA 8333.................................................. 89 CA 8336.................................................. 90 CA 8345.................................................. 92 CA 8436.................................................. 91 CA 847.................................................. 122 CA 850.................................................. 123 CA 876.................................................. 118 CA 895.................................................. 127 CA 922.................................................... 27 CA 942.................................................... 27 CDA 9452.............................................. 127 CX 1651................................................ 208 CX 1652................................................ 222 D D30CN................................................... 140 D30N..................................................... 140 D31N..................................................... 140 D32N..................................................... 140 D33N..................................................... 140 D34N..................................................... 140 D35N..................................................... 140 D36N..................................................... 140 D37N..................................................... 140 D38N..................................................... 140 DATAVIEW®.............................. 74, 102, 130 DL913................................................... 101 DL914................................................... 101 DOX 2025B............................................ 223 DOX 2070B............................................ 223 DOX 2100B............................................ 223 DOX 3104.............................................. 184 DOX 3304.............................................. 184 DTR 8510................................................ 71 E E25........................................................ 141 E27........................................................ 141 F F201........................................................ 30 F203........................................................ 30 F205........................................................ 30 F401........................................................ 31 F403........................................................ 31 F405........................................................ 31 F407...................................................... 220 F603........................................................ 31 F605........................................................ 31 F607...................................................... 220 F65.......................................................... 55 FTV500.................................................... 93 G GX 1025................................................ 204 GX 1050................................................ 204 GX 305.................................................. 202 GX 310.................................................. 202 GX 320.................................................. 202 H HX0003................................................. 212 HX0004................................................. 212 HX0005................................................. 212 HX0006................................................. 212 HX0027................................................. 213 HX0108................................................. 212 HX0206................................................. 213 HX0210................................................. 213 HX0220................................................. 213 K K1......................................................... 141 K2......................................................... 141 L L411........................................................ 98 L412........................................................ 99 L452...................................................... 101 L461...................................................... 100 M MA110................................................... 142 MA130................................................... 142 MA200................................................... 142 MA4000D-350......................................... 28 MA400D-170........................................... 28 MA400D-250........................................... 28 MH60.................................................... 141 MINI 01.................................................. 139 MINI 02.................................................. 139 MINI 03.................................................. 139 MINI 05.................................................. 139 MINI 09.................................................. 139 MINI102................................................. 139 MINI103................................................. 139 MN08.................................................... 139 MN09.................................................... 139 MN10.................................................... 139 MN11.................................................... 139 MN12.................................................... 139 MN13.................................................... 139 MN14.................................................... 139 MN15.................................................... 139 MN21.................................................... 139 MN23.................................................... 139 MN38.................................................... 139 MN39.................................................... 139 MN60.................................................... 139 MN71.................................................... 139 MN73.................................................... 139 MN88.................................................... 139 MN89.................................................... 139 MTX 1032-B.......................................... 214 MTX 1032-C.......................................... 214 MTX 1050.............................................. 198 MTX 3290.............................................. 168 MTX 3291.............................................. 168 MTX202.................................................. 166 MTX203................................................. 166 MTX204................................................. 166 MX 350.................................................. 175 MX 355.................................................. 175 MX 406B................................................ 179 MX 5006................................................ 170 MX 5060................................................ 170 MX 531.................................................. 178 MX 604.................................................. 179 MX 650.................................................. 176 MX 655.................................................. 176 MX 670.................................................. 177 MX 675.................................................. 177 MX 9030................................................ 214 MX1....................................................... 161 O OX 9302-BUS......................................... 190 OX 9062................................................ 188 OX 9102................................................ 188 OX 9104................................................. 188 OX 9304................................................ 188 P PAC15................................................... 141 PAC16................................................... 141 PAC17................................................... 141 PAC25.................................................... 141 PAC26................................................... 141 PAC27................................................... 141 PEL 106................................................... 97 PEL102.................................................... 96 PEL103.................................................... 96 PEL104.................................................... 96 PEL51...................................................... 95 PEL52...................................................... 95 PROBIX.................................................. 192 PUISS-HARM.......................................... 147 S ScopeNet IV............................................ 194 SX METRO.............................................. 195 SX-DMM................................................ 171 T TCX 01................................................... 162 TK 2000................................................. 119 TK 2002................................................. 119 TX01...................................................... 161 V VX0003.................................................. 162 VX0100.................................................. 162 Y Y1N....................................................... 139 Y2N....................................................... 139 Y3N....................................................... 139 Y4N....................................................... 139 Y7N....................................................... 139 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3221 INDEX > BY REFERENCE BY REFERENCE AG1066-Z................................................155 AT0094......................................................81 AX1360-P................................................207 CX1651...................................................209 CX1652...................................................209 DOX-MSO3LA...........................................185 DOX2025B...............................................183 DOX2070B...............................................183 DOX2100B...............................................183 DOX3104.................................................185 DOX3304.................................................185 GX1025...................................................205 GX1050...................................................205 GX305.....................................................203 GX310.....................................................203 GX310-P..................................................203 GX320.....................................................203 GX320-E..................................................203 HA030-1..................................................210 HX0003...................................................212 HX0004...................................................212 HX0005...................................................212 HX0006...................................................212 HX0027...................................................213 HX0029B........................................... 26-172 HX0030C.................................................192 HX0031...................................................192 HX0032...................................................192 HX0033...................................................192 HX0034B.................................................192 HX0035B.................................................192 HX0036...................................................192 HX0051B...................................................26 HX0051B...................................................81 HX0051B.................................................155 HX0053...................................................138 HX0053...................................................155 HX0055B.................................................107 HX0056-Z..................................................81 HX0056-Z..................................................82 HX0056Z.................................................107 HX0059B........................................... 26-172 HX0061.....................................................76 HX0061...................................................107 HX0064...................................................155 HX0072...................................................192 HX0073...................................................192 HX0074...................................................192 HX0080...................................................192 HX0082...................................................199 HX0083...................................................199 HX0091.....................................................83 HX0091...................................................107 HX0091...................................................155 HX0093...................................................192 HX0094...................................................192 HX0099.....................................................27 HX0106...................................................155 HX0106...................................................203 HX0107...................................................155 HX0107...................................................203 HX0108...................................................212 HX0122.....................................................94 HX0130 ..................................................192 HX0179...................................................192 HX0206...................................................213 HX0210...................................................213 HX0220...................................................213 HX0300.....................................................76 HX0300.....................................................81 HX0302.....................................................76 HX0302.....................................................81 HX0302...................................................157 MTX 1032-B............................................214 MTX 1032-C............................................214 MTX1050-PC...........................................199 MTX202-Z................................................166 MTX203-Z................................................166 MTX204-Z................................................166 MTX3290.................................................168 MTX3291.................................................168 MX 9030..................................................214 MX0001-T...............................................161 MX0350Z.................................................175 MX0355Z.................................................175 MX0406B.................................................179 MX0531...................................................178 MX0604...................................................179 MX0650-Z...............................................176 MX0655-Z...............................................176 MX0670-Z...............................................177 MX0675-Z...............................................177 MX1.........................................................161 OX9062...................................................191 OX9102...................................................191 OX9104...................................................191 OX9302-BUS............................................190 OX9304...................................................191 P01101141...............................................82 P01101783...............................................80 P01101783...............................................82 P01101784...............................................80 P01101785.............................................138 P01101794...............................................82 P01101797.............................................138 P01101841...............................................79 P01101841...............................................82 P01101842...............................................82 P01101846.............................................155 P01101847.............................................155 P01101892A...........................................147 P01101892A...........................................210 P01101905...............................................81 P01101906A.............................................81 P01101915...............................................79 P01101915...............................................82 P01101916...............................................79 P01101916...............................................82 P01101917...............................................79 P01101917...............................................82 P01101918...............................................82 P01102182...............................................79 P01101919...............................................79 P01101919...............................................82 P01101921...............................................76 P01101922...............................................76 P01101935...............................................51 P01101935...............................................81 P01101941...............................................81 P01101943...............................................76 P01101959...............................................98 P01101959.............................................106 P01101959.............................................107 P01101959.............................................107 P01101967.............................................107 P01101967.............................................107 P01101981.............................................148 P01101994.............................................131 P01101995.............................................131 P01101996...............................................79 P01101997Z..............................................19 P01101997Z............................................154 P01102008Z............................................154 P01102009Z............................................154 P01102013...............................................80 P01102013...............................................82 P01102014...............................................82 P01102017...............................................76 P01102017...............................................78 P01102017...............................................81 P01102018...............................................76 P01102018...............................................78 P01102019...............................................81 P01102020...............................................78 P01102020...............................................81 P01102021...............................................76 P01102021...............................................78 P01102021...............................................81 P01102022...............................................76 P01102022...............................................78 P01102023...............................................78 P01102024...............................................78 P01102025...............................................78 P01102026...............................................78 P01102026...............................................81 P01102026...............................................82 P01102028...............................................78 P01102028...............................................82 P01102029...............................................78 P01102030...............................................78 P01102031...............................................78 P01102031...............................................81 P01102035...............................................81 P01102036B.............................................81 P01102037...............................................78 P01102040...............................................78 P01102045...............................................82 P01102046...............................................78 P01102046...............................................78 P01102046...............................................82 P01102047...............................................78 P01102052Z............................................107 P01102053Z............................................155 P01102055Z............................................155 P01102056...............................................80 P01102056...............................................82 P01102057...............................................76 P01102057.............................................107 P01102057Z............................................107 P01102059.............................................107 P01102080...............................................98 P01102080.............................................106 P01102080.............................................107 P01102081...............................................98 P01102081.............................................107 P01102082...............................................83 P01102082.............................................107 P01102083.............................................138 P01102084A.............................................43 P01102084A.............................................76 P01102084A.............................................81 P01102092...............................................81 P01102092A.............................................76 P01102094...............................................76 P01102095...............................................74 P01102095...............................................76 P01102095...............................................81 P01102095.............................................104 P01102095.............................................106 P01102095.............................................107 P01102095.............................................107 P01102095.............................................111 P01102095.............................................132 P01102095.............................................138 P01102097.............................................155 P01102099.............................................107 P01102100Z..............................................17 P01102100Z............................................138 P01102100Z............................................156 P01102100Z............................................157 P01102101Z............................................155 P01102103...............................................80 P01102103...............................................82 P01102106Z............................................155 P01102107Z............................................155 P01102112...............................................81 P01102112.............................................138 P01102113...............................................17 P01102114Z..............................................80 P01102114Z..............................................82 P01102114Z............................................155 P01102115...............................................95 P01102117.............................................107 P01102121Z............................................154 P01102123Z............................................154 P01102124Z............................................154 P01102125Z............................................154 P01102126Z............................................154 P01102127Z............................................154 P01102128Z............................................154 P01102129...............................................76 P01102130...............................................76 P01102130...............................................94 P01102131.............................................106 P01102131.............................................107 P01102135...............................................79 P01102136...............................................79 P01102136...............................................82 P01102137...............................................79 P01102137...............................................82 P01102138...............................................79 P01102138...............................................82 P01102139...............................................79 P01102139...............................................82 P01102140...............................................79 P01102140...............................................82 P01102141...............................................79 P01102142...............................................79 P01102142...............................................82 P01102143...............................................79 P01102143...............................................82 P01102144...............................................79 P01102144...............................................82 P01102145...............................................79 P01102145...............................................82 P01102146.............................................107 P01102147.............................................107 P01102148.............................................103 P01102148.............................................107 P01102149.............................................106 P01102149.............................................107 P01102149.............................................156 P01102150.............................................107 P01102152Z..............................................17 P01102152Z..............................................17 P01102152Z............................................154 P01102153Z..............................................17 P01102153Z............................................154 P01102154Z..............................................17 P01102154Z............................................154 P01102155...............................................94 P01102155.............................................107 P01102157...............................................42 P01102157...............................................76 P01102157...............................................81 P01102171...............................................81 P01102172...............................................81 P01102173...............................................81 P01102174...............................................98 P01102174.............................................107 P01102177...............................................79 P01102177...............................................82 P01102178...............................................79 P01102178...............................................82 P01102179...............................................79 P01102179...............................................82 P01102180...............................................79 P01102180...............................................82 P01102182...............................................82 P01102184...............................................95 P01102186...............................................76 P01102186...............................................81 P01102188...............................................27 P01102190.............................................138 P01102191...............................................79 P01102192...............................................79 P01102193...............................................79 P01102195...............................................79 P01102199...............................................80 P01102200...............................................80 P01102201...............................................80 P01102202...............................................80 P01102903...............................................81 P01102903...............................................82 P01103057.............................................138 P01103058Z............................................107 P01103058Z............................................155 P01103059Z............................................154 P01103060Z............................................154 P01103061Z............................................154 P01103062...............................................81 P01103063...............................................80 P01103063...............................................82 P01103065...............................................80 P01103065...............................................82 P01103071...............................................82 P01103072...............................................82 P01103073...............................................82 P01103076...............................................94 P01103076.............................................107 P01103077...............................................94 P01103077.............................................107 P01103078...............................................94 P01103078.............................................107 P01103079...............................................94 P01103079.............................................107 P01103080...............................................27 P01105101Z............................................141 P01105102Z............................................141 P01105102Z ...........................................173 P01105103Z............................................141 P01105103Z ...........................................173 P01105105Z............................................141 P01105105Z............................................173 P01105109Z............................................141 P01105109Z............................................173 P01106102.............................................141 P01106103.............................................141 P01120001A...........................................141 P01120005A...........................................141 P01120025.............................................143 P01120025.............................................173 P01120027.............................................106 P01120027.............................................107 P01120027.............................................143 P01120028A...........................................141 P01120029A...........................................141 P01120043A.............................................98 P01120049A...........................................142 P01120050A...........................................142 P01120051A...........................................142 P01120052A...........................................142 P01120053A...........................................142 P01120054A...........................................142 P01120055A...........................................142 P01120056A...........................................142 P01120057A...........................................142 P01120064.............................................142 P01120067A...........................................143 P01120074A...........................................143 P01120074A ..........................................173 P01120075 ..........................................141 P01120079B.............................................98 P01120079B...........................................106 P01120080...............................................95 P01120083.............................................142 P01120110...............................................98 P01120110.............................................106 P01120115.............................................143 P01120116.............................................143 P01120116 ............................................173 P01120117.............................................143 P01120125.............................................143 P01120125.............................................173 P01120126.............................................143 P01120127.............................................143 P01120301.............................................142 P01120302.............................................142 P01120303.............................................142 P01120304.............................................142 P01120304.............................................173 P01120305.............................................142 P01120305.............................................173 P01120306.............................................142 P01120307.............................................142 P01120308.............................................142 P01120309.............................................142 P01120310...............................................78 P01120310...............................................78 P01120310...............................................81 P01120314.............................................142 P01120315.............................................142 P01120316.............................................142 P01120317.............................................142 P01120323B.............................................98 P01120323B...........................................106 P01120330...............................................81 P01120333...............................................78 P01120333...............................................81 P01120335...............................................76 P01120335...............................................78 P01120336...............................................76 P01120336...............................................78 P01120401.............................................173 P01120401 .........................................141 P01120402.............................................173 P01120402 ..........................................141 P01120403.............................................141 P01120404.............................................141 P01120405.............................................141 P01120406.............................................141 P01120407.............................................141 P01120408.............................................141 P01120409.............................................141 P01120410.............................................141 P01120415.............................................141 P01120415.............................................173 P01120416.............................................141 P01120417.............................................141 P01120418.............................................141 P01120419.............................................141 P01120420.............................................141 P01120420.............................................173 P01120421...............................................76 P01120421...............................................81 P01120421.............................................141 P01120421 ............................................173 P01120425B.............................................98 P01120425B...........................................106 P01120434B.............................................98 P01120434B...........................................106 P01120439...............................................42 P01120439...............................................76 P01120439...............................................81 P01120440...............................................81 P01120452...............................................81 P01120460...............................................76 P01120470...............................................80 P01120470...............................................82 P01120526B ..........................................106 P01120531B.............................................98 P01120531B...........................................106 P01120550...............................................78 P01120550...............................................82 P01120551...............................................78 P01120551...............................................82 P01120552...............................................98 P01120552...............................................99 P01120554.............................................106 P01120556B.............................................98 P01120568...............................................98 P01120568...............................................99 P01120568.............................................106 P01120570.............................................144 P01120571.............................................144 P01120572.............................................144 P01120575Z..............................................28 P01120576Z..............................................28 P01120577Z..............................................28 P01120592...............................................98 P01120592 ............................................106 P01120593...............................................98 P01120593.............................................106 P01120594...............................................98 P01120594.............................................106 P01120600...............................................95 P01120612.............................................143 P01120630.............................................144 P01120630.............................................173 P01120631.............................................144 P01120632.............................................144 P01120633.............................................144 P01120660.............................................144 P01120660 ............................................173 P01120661.............................................144 P01120661 ............................................173 P01120662.............................................144 P01120663.............................................144 P01120761...............................................55 P01120872...............................................80 P01120872...............................................81 P01120921...............................................30 P01120923...............................................30 P01120925...............................................30 P01120941...............................................31 P01120943...............................................31 P01120945...............................................31 P01120947...............................................89 P01120963...............................................31 P01120965...............................................31 P01120967...............................................89 P01122015...............................................62 P01122016...............................................62 P01122018...............................................62 P01122301...............................................81 P01126501...............................................58 P01126502...............................................58 P01126504...............................................60 P01126505...............................................59 P01126506...............................................59 P01126510...............................................61 P01127012...............................................57 P01127014...............................................57 P01129501.............................................131 P01129600...............................................95 P01132503...............................................46 P01132504...............................................46 P01138901...............................................51 P01138902...............................................51 P01139711...............................................52 P01139712...............................................53 P01139713...............................................53 P01139714...............................................52 P01139715...............................................54 P01139716...............................................54 P01140201...............................................46 P01140301...............................................46 P01140822...............................................48 P01140824...............................................48 P01140826...............................................48 P01140832...............................................49 P01140834...............................................49 P01140836...............................................49 P01140838...............................................47 P01141626...............................................73 P01143200...............................................69 P01143221...............................................69 P01143300...............................................70 P01145445...............................................40 P01145455...............................................40 P01145460...............................................40 P01145811...............................................64 P01145831...............................................64 P01145851...............................................65 P01145901.............................................148 222 TESTCA&TMAELOAGSUREETMESETNT& CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrinno-aurxn.cooumx.com INDEX > BY REFERENCE BY REFERENCE P01146011...............................................42 P01146013...............................................42 P01156302Z............................................124 P01156401.............................................138 P01156401.............................................138 P01156402.............................................138 P01157152...............................................98 P01157153...............................................98 P01157154...............................................98 P01157165...............................................99 P01157166...............................................97 P01157167...............................................97 P01157170.............................................103 P01157171.............................................103 P01157180.............................................100 P01157181.............................................101 P01157182.............................................102 P01157201.............................................103 P01157702...............................................71 P01160511...............................................90 P01160541...............................................91 P01160591...............................................92 P01160595...............................................93 P01160620...............................................89 P01160640.............................................107 P01160657...............................................94 P01165221.............................................147 P01165222.............................................147 P01165223.............................................147 P01165224.............................................147 P01165225.............................................147 P01167501.............................................131 P01174810.............................................128 P01174830.............................................128 P01174835.............................................138 P01174902.............................................128 P01174902.............................................138 P01174903.............................................128 P01174903.............................................138 P01184101.............................................125 P01184102.............................................125 P01185301.............................................138 P01185501Z............................................126 P01191303...............................................72 P01191304...............................................72 P01191305...............................................72 P01191306...............................................44 P01191611...............................................43 P01191739Z..............................................24 P01191740Z..............................................24 P01191742D.............................................19 P01191742Z..............................................19 P01191745Z..............................................16 P01191748Z..............................................17 P01191748Z..............................................20 P01191748Z............................................155 P01191755...............................................17 P01191757...............................................17 P01191762D.............................................19 P01191762Z..............................................19 P01191771...............................................20 P01191771A.............................................20 P01191773...............................................20 P01191773A.............................................20 P01192200...............................................27 P01194200...............................................27 P01196311E..............................................22 P01196521E..............................................22 P01196522E..............................................22 P01196523E..............................................22 P01196731...............................................24 P01196733...............................................24 P01196734...............................................24 P01196773.................................................5 P01196775...............................................25 P01196777...............................................25 P01196802...............................................26 P01196803...............................................26 P01196812...............................................26 P01196813...............................................26 P01197201...............................................81 P01197401.............................................147 P01197401.............................................210 P01197402.............................................147 P01197402.............................................210 P01197403.............................................147 P01197404.............................................147 P01197404.............................................210 P01197451.............................................147 P01197451.............................................210 P01275101.............................................150 P01275301.............................................151 P01275302.............................................151 P01275304.............................................150 P01275304.............................................151 P01275305.............................................151 P01275306.............................................151 P01275307.............................................151 P01275308.............................................151 P01275309.............................................151 P01275310.............................................151 P01275311.............................................151 P01275312.............................................151 P01275313.............................................151 P01275314.............................................151 P01275315.............................................151 P01275316.............................................151 P01275318.............................................151 P01275325.............................................150 P01275326.............................................150 P01275327.............................................150 P01275328.............................................150 P01275329.............................................150 P01275330.............................................150 P01275331.............................................150 P01275332.............................................150 P01275333.............................................150 P01275334.............................................150 P01275335.............................................150 P01275339.............................................151 P01275340.............................................151 P01275341.............................................151 P01275343.............................................151 P01275344.............................................151 P01275345.............................................151 P01275346.............................................151 P01275347.............................................151 P01275348.............................................151 P01275349.............................................151 P01275350.............................................151 P01275351.............................................151 P01275352.............................................151 P01275353.............................................151 P01275357.............................................151 P01275358.............................................151 P01275359.............................................151 P01275360.............................................151 P01275361.............................................151 P01275362.............................................151 P01295056.............................................147 P01295056.............................................147 P01295094...............................................76 P01295097...............................................79 P01295097...............................................82 P01295137...............................................79 P01295137...............................................82 P01295140...............................................79 P01295140...............................................82 P01295141...............................................79 P01295141...............................................82 P01295143A.............................................80 P01295143A.............................................82 P01295145...............................................82 P01295171...............................................81 P01295172...............................................79 P01295172...............................................81 P01295172...............................................82 P01295173...............................................79 P01295173...............................................81 P01295174................................76 - 81 - 98 P01295174.............................................107 P01295212.............................................148 P01295231...............................................77 P01295232...............................................77 P01295234...............................................79 P01295236...............................................79 P01295236...............................................82 P01295252...............................................81 P01295252...............................................81 P01295253...............................................81 P01295253...............................................82 P01295260...............................................78 P01295261...............................................78 P01295262...............................................78 P01295263...............................................78 P01295264...............................................78 P01295265...............................................78 P01295266...............................................78 P01295266...............................................81 P01295267...............................................78 P01295268...............................................78 P01295268...............................................81 P01295268...............................................82 P01295270...............................................78 P01295271...............................................61 P01295271...............................................82 P01295272...............................................82 P01295285Z............................................154 P01295288Z............................................107 P01295288Z............................................152 P01295289Z..............................................81 P01295289Z............................................152 P01295290Z............................................152 P01295291...............................................78 P01295291...............................................82 P01295292...............................................78 P01295292...............................................82 P01295293...............................................76 P01295293...............................................82 P01295293.............................................106 P01295293.............................................107 P01295293.............................................138 P01295294...............................................82 P01295393...............................................40 P01295393...............................................76 P01295398...............................................40 P01295398...............................................76 P01295450Z..............................................81 P01295450Z............................................152 P01295451Z............................................138 P01295451Z............................................152 P01295452Z............................................152 P01295453Z..............................................81 P01295453Z............................................152 P01295454Z..............................................81 P01295454Z............................................107 P01295454Z............................................153 P01295455Z............................................152 P01295456Z..............................................81 P01295456Z............................................152 P01295457Z..............................................81 P01295457Z..............................................82 P01295457Z............................................138 P01295457Z............................................155 P01295458Z..............................................81 P01295458Z..............................................82 P01295458Z............................................138 P01295458Z............................................153 P01295459Z..............................................22 P01295459Z............................................155 P01295460Z............................................153 P01295461Z............................................152 P01295462Z............................................154 P01295463Z............................................154 P01295464Z............................................154 P01295465...............................................77 P01295474Z............................................153 P01295475Z............................................153 P01295476...............................................98 P01295476.............................................106 P01295476.............................................107 P01295477.............................................107 P01295479...............................................98 P01295479...............................................99 P01295479.............................................107 P01295483.............................................106 P01295483.............................................107 P01295486...............................................80 P01295486...............................................82 P01295487...............................................80 P01295487...............................................82 P01295488...............................................80 P01295488...............................................82 P01295489.............................................103 P01295491Z............................................153 P01295492...............................................43 P01295492...............................................81 P01295493...............................................81 P01295494...............................................80 P01295494...............................................82 P01295495...............................................80 P01295495...............................................82 P01295496.............................................107 P01295501.............................................138 P01295502.............................................138 P01295506...............................................77 P01295507...............................................77 P01295508...............................................77 P01295510...............................................77 P01295511...............................................77 P01295512...............................................77 P01295513...............................................77 P01295514...............................................77 P01295515...............................................77 P01295516...............................................77 P01295517...............................................77 P01295518...............................................77 P01295519...............................................77 P01295520...............................................77 P01295521...............................................77 P01295522...............................................77 P01295523...............................................77 P01295524...............................................77 P01295525...............................................77 P01295526...............................................77 P01296021...............................................81 P01296024...............................................76 P01296024.............................................107 P01296032...............................................16 P01296032...............................................17 P01296032...............................................17 P01296033...............................................81 P01296034...............................................81 P01296037.............................................107 P01296047...............................................76 P01296047...............................................94 P01297012...............................................81 P01297022...............................................81 P01297071...............................................81 P01297072...............................................81 P01297086...............................................79 P01297086...............................................82 P01297089...............................................82 P01297090...............................................82 P01297095...............................................81 P01297101...............................................82 P01297102...............................................79 P01297102...............................................82 P01297103...............................................79 P01297103...............................................82 P01298004.............................................156 P01298004.............................................157 P01298005...............................................81 P01298005.............................................157 P01298006...............................................81 P01298006.............................................156 P01298006.............................................157 P01298007.............................................156 P01298007.............................................157 P01298009B...........................................157 P01298011.............................................156 P01298011.............................................157 P01298012.............................................156 P01298012.............................................157 P01298012Z............................................157 P01298015.............................................157 P01298016...............................................81 P01298016.............................................157 P01298031.............................................156 P01298031.............................................157 P01298032.............................................156 P01298032.............................................157 P01298033.............................................156 P01298033.............................................157 P01298036.............................................156 P01298036.............................................157 P01298037.............................................156 P01298037.............................................157 P01298037A...........................................156 P01298037A...........................................157 P01298040.............................................157 P01298043Z............................................156 P01298043Z............................................157 P01298046.............................................157 P01298049...............................................81 P01298049.............................................107 P01298049.............................................156 P01298049.............................................157 P01298051...............................................81 P01298051.............................................156 P01298051.............................................157 P01298055.............................................107 P01298055.............................................156 P01298055.............................................157 P01298056...............................................76 P01298056.............................................106 P01298056.............................................156 P01298056.............................................157 P01298057...............................................76 P01298057.............................................157 P01298061A...........................................156 P01298065Z..............................................24 P01298065Z..............................................81 P01298065Z............................................156 P01298065Z............................................157 P01298066...............................................81 P01298066...............................................82 P01298066...............................................82 P01298066.............................................107 P01298066.............................................156 P01298066.............................................157 P01298067...............................................82 P01298067.............................................107 P01298067.............................................156 P01298067.............................................157 P01298068.............................................156 P01298069.............................................156 P01298071...............................................97 P01298071.............................................138 P01298071.............................................156 P01298072.............................................156 P01298072.............................................157 P01298074...............................................17 P01298074.............................................156 P01298074.............................................157 P01298075.............................................138 P01298075.............................................156 P01298075.............................................157 P01298076.............................................101 P01298076.............................................107 P01298076.............................................156 P01298076.............................................157 P01298078...............................................98 P01298078.............................................107 P01298078.............................................156 P01298078.............................................157 P01298080...............................................81 P01298080.............................................157 P01298081...............................................76 P01298082...............................................76 P01298083...............................................94 P01298083.............................................107 P01299926...............................................43 P01637301.............................................107 P01651001Z............................................129 P01651011.............................................130 P01651020.............................................138 P01651021.............................................138 P01651022.............................................138 P01651023.............................................107 P01651023.............................................138 P01651023.............................................155 P01651030.............................................126 P01651101.............................................129 P01651101.............................................138 P01651403Z............................................120 P01651610Z............................................120 P01651620.............................................148 P01651813.............................................119 P01651814.............................................119 P01651815.............................................119 P01651816.............................................119 P01651901.............................................114 P01651902.............................................113 P01651904.............................................115 P01653100.............................................121 P01653110.............................................121 P01654110.............................................127 P01654227.............................................125 P01654246...............................................81 P01654246...............................................82 P01654246.............................................124 P01654250.............................................138 P01654251.............................................138 P01654252.............................................101 P01654252.............................................138 P01654253.............................................138 P01654402.............................................112 P01654621.............................................111 P01654623.............................................111 P01654821.............................................122 P01654822.............................................122 P01654823.............................................123 P01655010.............................................136 P01655020.............................................137 P01700105.............................................138 P01700106.............................................133 P01700106.............................................138 P01700107.............................................133 P01700107.............................................138 P01700108.............................................138 P01700109.............................................133 P01700109.............................................138 P01700114.............................................138 P01700115.............................................138 P01700116.............................................138 P01700117.............................................135 P01700117.............................................138 P01700118.............................................135 P01700118.............................................138 P01700119.............................................138 P01710010.............................................134 P01710015.............................................133 P01710016.............................................133 P01710020.............................................135 P01710050.............................................138 P01710050.............................................138 P01710051.............................................134 P01710051.............................................138 P01710052.............................................134 P01710052.............................................138 P01710053.............................................138 P01710054.............................................138 P01710055.............................................138 P01710056.............................................133 P01710056.............................................138 P01NC5003.............................................149 P03197521A...........................................147 P03197521A ..........................................210 P03197522A...........................................147 P03197522A ..........................................210 P03197523A...........................................147 P03197523A...........................................210 P03197524A...........................................147 P03197524A...........................................210 P03197525A...........................................147 P03197525A...........................................210 P03197526A...........................................147 P03197526A...........................................210 P03197527A...........................................147 P03197527A...........................................210 P03197528A...........................................147 P03197528A...........................................210 P03197704.............................................129 P03199611A...........................................147 P03199612A...........................................147 P03199613A...........................................147 P03295509...............................................22 P03295509...............................................81 P03295509.............................................107 P03295509.............................................155 P03297514...............................................81 P03298504.............................................157 P03652712.............................................137 P03652713.............................................137 P03652714.............................................137 P03652715.............................................137 P03652901.............................................136 P03652902.............................................136 P03652903.............................................136 P03652904.............................................136 P03652905.............................................136 P03652906.............................................136 P03652907.............................................136 P03652908.............................................136 P03652909.............................................137 P03652910.............................................137 P03652912.............................................137 P03652913.............................................137 P03652914.............................................137 P03652917.............................................136 P03652918.............................................136 P03652919.............................................136 P03652920.............................................136 P03652921.............................................136 P03652922.............................................136 P03652925.............................................137 P06239307.............................................155 P06239502...............................................81 P06239502.............................................156 P06239502.............................................157 SX-METRO/P..............................................27 SX-METRO/P............................................195 TCX001-Z................................................162 TX0001-Z................................................161 VX0003....................................................162 VX0100....................................................162 TESTCA&TMAELOAGSUREETMEESNT T&CMAETSAULROEGU20E221022 wwww.cwhwau.cvhinau-avrino-aurxn.cooumx.com 3223 906131153 - Ed. 1 - 02/2022 - Non-contractual document. Specifications subject to modification due to technological developments. 10 SUBSIDIARIES WORLDWIDE AUSTRIA CHAUVIN ARNOUX GES.M.B.H Slamastrasse 29/2/4 par Gastgegasse 27 Tel.: +43 1 61 61 9 61 Fax: +43 1 61 61 9 61-61 [email protected] www.chauvin-arnoux.at CHINA SHANGHAI PU-JIANG ENERDIS INSTRUMENTS CO., LTD. 3 Floor, 23 Building Gemdale Viseen Minhang Technology & Industrial Park Project 1288 lane, Zhongchun Road Minhang District, SHANGHAI City. Tel.: +86 21 65 21 51 96 Fax: +86 21 65 21 61 07 [email protected] GERMANY CHAUVIN ARNOUX GMBH Ohmstraße 1 77694 KEHL / RHEIN Tel.: +49 07851 99 26-0 Fax: +49 07851 99 26-60 [email protected] www.chauvin-arnoux.de ITALY AMRA SPA Via Sant'Ambrogio, 23 20846 MACHERIO (MB) Tel.: +39 039 245 75 45 Fax: +39 039 481 561 [email protected] www.chauvin-arnoux.it MIDDLE EAST CHAUVIN ARNOUX MIDDLE EAST PO Box 60-154 1241 2020 JAL EL DIB (Beirut) - LEBANON Tel.: +961 1 890 425 Fax: +961 1 890 424 [email protected] www.chauvin-arnoux.com SCANDINAVIA CA MÄTSYSTEM AB Sjöflygvägen 35 SE-183 62 TABY Tel.: +46 8 50 52 68 00 Fax: +46 8 50 52 68 10 [email protected] www.camatsystem.com SPAIN CHAUVIN ARNOUX IBÉRICA SA C/ Roger de Flor N°293 1a Planta 08025 BARCELONA Tel.: +34 902 20 22 26 Fax: +34 934 59 14 43 [email protected] www.chauvin-arnoux.es SWITZERLAND CHAUVIN ARNOUX AG Moosacherstrasse 15 8804 AU / ZH Tel.: +41 44 727 75 55 Fax: +41 44 727 75 56 [email protected] www.chauvin-arnoux.ch USA CHAUVIN ARNOUX INC d.b.a AEMC Instruments 15 Faraday Drive Dover - NH 03820 Tel. : +1 (800) 945-2362 Fax : +1 (603) 742-2346 [email protected] www.aemc.com INTERNATIONAL CHAUVIN ARNOUX 12-16 Rue Sarah Bernhardt 92600 Asnières-Sur-Seine Tel.: +33 1 44 85 44 38 Fax: +33 1 46 27 95 59 [email protected] www.chauvin-arnoux.fr UNITED KINGDOM CHAUVIN ARNOUX LTD Unit 1 Nelson Ct, Flagship Sq Shaw Cross Business Pk, Dewsbury West Yorkshire - WF12 7TH Tel.: 019240460494 Fax: 01924 455 328 [email protected] www.chauvin-arnoux.com MIDDLE EAST CHAUVIN ARNOUX MIDDLE EAST PO Box 60-154 1241 2020 JAL EL DIB (Beirut) - LEBANON Tel.: +961 1 890 425 Fax: +961 1 890 424 [email protected] www.chauvin-arnoux.com USA CHAUVIN ARNOUX d.b.a AEMC Instruments 15 Faraday Drive Dover - NH 03820 Tel. : +1 (800) 945-2362 Fax : +1 (603) 742-2346 [email protected] www.aemc.comAdobe InDesign 17.0 (Macintosh) Adobe PDF Library 16.0.3