MPE ESTIMATION

FCC ID: 2BE89-NL15M 1, According to §1.1310, Limit for General Population/ Uncontrolled Exposures
Frequency Power density (mW/ cm2 ) Averaging time(minutes)

300MHz----1.5GHz

F/1500

30

1.5GHz---100GHz

1.0

30

Note: F= Frequency in MHz

2, Estimation Result
Frequency Max PK Output Tune Up Max Tune Up Antenna Antenna Gain MPE (MHz) power(dBm) Power(dBm) power(mW) Gain(dBi) (numerical) (mW/cm²)

BLE

2402

2.37

2±1(3)

1.995

0

1.0

0.00040

Note: Note: The estimation distance is 20cm Note:
PK Output power= conducted power in mW. G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna in cm Conducted power see the test report HK2503251428-E, antenna gain=0dBi
When the minimum test separation distance is >20 cm, a distance of 20 cm is applied to determine RF Exposure test exclusion. The test exclusion threshold is 0.00040mW/cm² which is< 1.0mW/cm², RF Exposure testing is not required.