File Info : application/pdf, 29 Pages, 1.65MB
Document DEVICE REPORTGetApplicationAttachment.html?id=8202209FCC TEST REPORT FCC ID: 2AH4J-LOCK420 On Behalf of Consumer 2.0 Rently Smart Bolt Elite Model No.: LOCK420-8Z, LOCK420-4Z Prepared for : Consumer 2.0 Address : 6300 Wilshire Blvd Suite 620, Los Angeles, CA 90048, United States Prepared By Address : Shenzhen PSI Testing Co., Ltd. 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, : Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Report Number Date of Receipt Date of Test Date of Report Version Number : psi2503155-C01-R03 : Dec. 24, 2024 : Dec. 24, 2024-Apr. 14, 2025 : Apr. 14, 2025 : V0 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Page 1 of 29 Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 2 of 29 Report No.: psi2503155-C01-R03 TABLE OF CONTENTS Description Page 1. General Information ..........................................................................................................5 1.1. Description of Device (EUT) ......................................................................................5 1.2. Accessories of Device (EUT) .................................................................................... 6 1.3. Ancillary Equipment Details ...................................................................................... 6 1.4. Test Lab Information ..................................................................................................6 2. Summary of test ................................................................................................................7 2.1. Summary of test result .............................................................................................. 7 2.2. Block Diagram ........................................................................................................... 7 2.3. Test mode .................................................................................................................. 7 2.4. Test Conditions ..........................................................................................................7 2.5. Measurement Uncertainty (95% confidence levels, k=2) ......................................... 8 2.6. Test Equipment ..........................................................................................................9 3. Occupied bandwidth and 20dB Bandwidth ................................................................. 10 3.1. Limit ......................................................................................................................... 10 3.2. Test Procedure ........................................................................................................ 10 3.3. Test Setup ............................................................................................................... 10 3.4. Test Result ...............................................................................................................10 4. Radiated emissions ........................................................................................................ 11 4.1. Limit ......................................................................................................................... 11 4.2. Block Diagram of Test setup ....................................................................................11 4.3. Test Procedure ........................................................................................................ 12 4.4. Test Result ...............................................................................................................13 5. Frequency stability ......................................................................................................... 20 5.1. Test limit .................................................................................................................. 20 5.2. Test Procedure ........................................................................................................ 20 5.3. Test Setup ............................................................................................................... 20 5.4. Test Results .............................................................................................................21 6. Power Line Conducted Emissions ................................................................................22 6.1. Block Diagram of Test Setup ...................................................................................22 6.2. Limit ......................................................................................................................... 22 6.3. Test Procedure ........................................................................................................ 22 6.4. Test Result ...............................................................................................................23 7. Antenna Requirements .................................................................................................. 28 7.1. Limit ......................................................................................................................... 28 7.2. Antenna Connected Construction ........................................................................... 28 7.3. Results .....................................................................................................................28 8. Photos of test setup ....................................................................................................... 29 9. Photos of EUT ................................................................................................................. 29 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 3 of 29 Report No.: psi2503155-C01-R03 Applicant Address Manufacturer Address EUT Description TEST REPORT DECLARATION : Consumer 2.0 : 6300 Wilshire Blvd Suite 620, Los Angeles, CA 90048, United States : Consumer 2.0 : 6300 Wilshire Blvd Suite 620, Los Angeles, CA 90048, United States : Rently Smart Bolt Elite (A) Model No. : LOCK420-8Z, LOCK420-4Z (B) Trademark : N/A Measurement Standard Used: FCC Rules and Regulations Part 15 Subpart C Section 15.225 ANSI C63.10:2013 Test Result: PASS The device described above is tested by Shenzhen PSI Testing Co., Ltd. to determine the maximum emission levels emanating from the device and the severe levels of the device can endure and its performance criterion. The test results are contained in this test report and Shenzhen PSI Testing Co., Ltd. is assumed full responsibility for the accuracy and completeness of test. Also, this report shows that the EUT is technically compliant with the FCC Part 15C requirements. This report applies to above tested sample only. This report shall not be reproduced in parts without written approval of Shenzhen PSI Testing Co., Ltd. Tested by (name + signature).............: Felix Pang Test Engineer Approved by (name + signature).......: Simple Guan Project Manager Date of issue................................: Apr. 14, 2025 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Revision V0 Issue Date Apr. 14, 2025 Page 4 of 29 Report No.: psi2503155-C01-R03 Revision History Revisions Initial released Issue Revised By Felix Pang Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 5 of 29 Report No.: psi2503155-C01-R03 1. General Information 1.1. Description of Device (EUT) Product Name : Rently Smart Bolt Elite Model No. Diff Power supply : LOCK420-8Z, LOCK420-4Z LOCK420-8Z is tested model, other models are derivative models . : The models are identical in circuit, only different on the model names and battery capacity and size : Input: DC 5V via adapter, DC 6V powered by battery Radio Technology Operation frequency Channel No. Modulation Antenna Type : NFC : 13.56MHz : 1 Channel : ASK : PCB antenna, Antenna gain 0dBi. Antenna information is provided by applicant. Software version Hardware Version/ FVIN : N/A : N/A Note: In this report, the main test model is LOCK420-8Z, and the main test model serial number is LOCK420-4Z. Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 6 of 29 Report No.: psi2503155-C01-R03 1.2. Accessories of Device (EUT) Accessories 1 : N/A Manufacturer : N/A Model : N/A Rating : N/A 1.3. Ancillary Equipment Details No. Description Manufacturer 1 AC/DC ADAPTER HUAWEI 2 N/A N/A Model HW-050450C00 N/A Serial Number AE N/A 1.4. Test Lab Information Shenzhen PSI Testing Co., Ltd. 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China September 13, 2023 File on Federal Communication Commission Registration Number: 916281 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 7 of 29 Report No.: psi2503155-C01-R03 2. Summary of test 2.1. Summary of test result Description of Test Item Conducted Emission Radiated emissions Fundamental field strength limit Frequency stability 20Db Emission Bandwidth Antenna Requirement Standard FCC IC 15.207 RSS-GEN 8.8 15.209 RSS-Gen 8.9 15.225 RSS 210 B.6 15.225 RSS 210 B.6 15.225 15.203 RSS 210 B.6 RSS-GEN(6.8) Results PASS PASS PASS PASS PASS PASS 2.2. Block Diagram EUT 2.3. Test mode Tested mode, channel, and data rate information Mode Channel Frequency(MHz) 1 CH1 13.56 Note: According exploratory test, EUT will have maximum output power in those data rate. So those data rate were used for all test. 2.4. Test Conditions Temperature range Humidity range Pressure range 21-25 40-75% 86-106kPa Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 8 of 29 Report No.: psi2503155-C01-R03 2.5. Measurement Uncertainty (95% confidence levels, k=2) Item Uncertainty Uncertainty for Power point Conducted Emissions Test Uncertainty for Radiation Emission test in 3m chamber (below 30MHz) Uncertainty for Radiation Emission test in 3m chamber (30MHz to 1GHz) Uncertainty for Radiation Emission test in 3m chamber (1GHz to 18GHz) Uncertainty for Radiation Emission test in 3m chamber (18GHz to 40GHz) Uncertainty for radio frequency Uncertainty for conducted RF Power Uncertainty for Power Spectral Density 2.17dB 3.5dB 2.74dB(Polarize: V) 2.76dB(Polarize: H) 4.29dB(Polarize: V) 4.82dB(Polarize: H) 4.31dB(Polarize: V) 4.30dB(Polarize: H) 48.24KHz 0.41dB 0.39 dB Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 9 of 29 Report No.: psi2503155-C01-R03 2.6. Test Equipment Item 1. 2. Equipment 9*6*6 anechoic chamber Test Receiver Manufacturer SKET Rohde&Schwarz Model No. 9*6*6 ESCI 7 Serial No. N/A 101032/003 Firmware Version Last Cal. Cal. Interval / 2022.12.20 3 Year 4.42 SP3 2024.12.18 1 Year 3. L.I.S.N.#1 Rohde&Schwarz ENV216 102282 / 2024.12.18 1 Year 4. L.I.S.N.#2 RFT NNB111 13835240 / 2024.12.18 1 Year 5. Loop Antenna Schwarz beck FMZB 1519B 00128 / 2025.01.02 2 Year 6. Bilog Antenna Schwarz beck VULB 9168 01448 / 2025.01.02 2 Year 7. Spectrum Analyzer Rohde&Schwarz FSV-40N 101648 3.70 2024.12.18 1 Year 8. Horn Antenna Schwarz beck BBHA 9120 D 02706 / 2025.01.02 2 Year 9. Amplifier SKET LAPA_01G1 SK20220329 8G-45dB 01 / 2024.12.18 1 Year 10. Horn Antenna Schwarz beck BBHA 9170 00946 / 2024.12.31 2 Year 11. Amplifier SKET LNPA_0118 SK20200108 G-45 01 / 2024.12.18 1 Year 12 RF Power Probe Rohde&Schwarz NRP-Z11 1138.3004.0 2-1111533-Fz / 2024.12.18 1 Year 13 RF Sensor Unit Tachoy TR1029-2 20220428P0 08 / 2024.12.18 1 Year 14 Spectrum Analyzer Agilent N9020A MY51281067 A.14.03 2024.12.18 1 Year 15 Temp. & Humid Chamber Auchno 9606 / / 2024.12.18 1 Year 16 Regulated DC Power Supply Xinouhua ADC120V10 20221125163 A 8 2024.12.18 1 Year 17 Cable SKET Cable-RE-1 #02/#03 / 2024.12.18 1 Year 18 Cable SKET Cable-RE-2 #01 / 2024.12.18 1 Year 19 Cable SKET Cable-RE-3 #04 / 2024.12.18 1 Year 20 Cable SKET Cable-CE-1 A-E-24 21 6dB Attenuator Schwarzbeck DGA 9552N 6dB CK4186 / 2024.12.18 1 Year / 2024.12.18 1 Year For Test Software Information Item Software Name RE EZ_EMC CE EZ_EMC RF RTS Manufacturer Farad Farad TACHOY Version PSI-3A1 PSI-3A1 V1.0.0 Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 10 of 29 Report No.: psi2503155-C01-R03 3. Occupied bandwidth and 20dB Bandwidth 3.1. Limit Intentional radiators operating under the alternative provisions to the general emission limits, as contained in FCC part 15.217 through 15.257 and in Subpart E of this part, must be designed to ensure that the 20 dB bandwidth of the emission, or whatever bandwidth may otherwise be specified in the specific rule section under which the equipment operates, is contained within the frequency band designated in the rule section under which the equipment is operated. 3.2. Test Procedure 1. The transmitter output was directly connected to a spectrum analyzer with a 50 cable. The bandwidth of the fundamental frequency was measured by spectrum analyzer with 3KHz RBW and 10kHz VBW. The 20dB bandwidth is defined as the total spectrum the power of which is higher than peak power minus 20dB. 2. The test receiver set RBW =1-5%BW, VBW3*RBW, Sweep time set auto, detail see the test plot for 99% Bandwidth. 3.3. Test Setup EUT Spectrum Analyzer 3.4. Test Result Modulation ASK Frequency (MHz) 13.56 20dB bandwidth (kHz) 9.673 Result Pass Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 11 of 29 Report No.: psi2503155-C01-R03 4. Radiated emissions 4.1. Limit 4.2. Block Diagram of Test setup In 3m Anechoic Chamber Test Setup Diagram for below 30MHz Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 12 of 29 Report No.: psi2503155-C01-R03 In 3m Anechoic Chamber Test Setup Diagram for frequency 30MHz-1GHz 4.3. Test Procedure Procedure of Preliminary Test The EUT and Support equipment, if needed, were put placed on a non-metallic table, 80cm above the ground plane. Configuration EUT to simulate typical usage as described in clause 2.4 and test equipment as described in clause 4.2 of this report. All I/O cables were positioned to simulate typical actual usage as per ANSI C63.10:2013. Mains cables, telephone lines or other connections to auxiliary equipment located outside the test are shall drape to the floor, be fitted with ferrite clamps or ferrite tubes placed on the floor at the point where the cable reaches the floor and then routed to the place where they leave the turntable. No extension cords shall be used to mains receptacle. The antenna was placed at 3 meter away from the EUT as stated in ANSI C63.10:2013. The antenna connected to the Spectrum Analyzer via a cable and at times a pre-amplifier would be used. The Receiver quickly scanned from 9KHz to 30MHz and 30MHz to 1GHz The EUT test program was started. Emissions were scanned and measured rotating the EUT to 360 degrees and positioning the antenna 1 to 4 meters above the ground plane, in both the vertical and the horizontal polarization, to maximize the emission reading level. The test mode(s) described in clause 2.4 were scanned during the preliminary test: After the preliminary scan, we found the test mode producing the highest emission level. The EUT and cable configuration, antenna position, polarization and turntable position of the above highest emission level were recorded for the final test. Procedure of Final Test EUT and support equipment were set up on the turntable as per the configuration with highest emission level in the preliminary test. The Receiver scanned from9KHz to 30MHz and 30MHz to 1GHz. Emissions were scanned and measured rotating the EUT to 360 degrees, varying cable placement and positioning the antenna 1 to 4 meters above the ground plane, in both the vertical and the horizontal polarization, to maximize the emission reading level. Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 13 of 29 Report No.: psi2503155-C01-R03 Recorded at least the six highest emissions. Emission frequency, amplitude, antenna position, polarization and turntable position were recorded into a computer in which correction factors were used to calculate the emission level and compare reading to the applicable limit and only Q.P. reading is presented. The test data of the worst-case condition(s) was recorded. The bandwidth of test receiver is set at 200Hz for 9 KHz to 150 KHz measure, 10 KHz for 150 KHz to 30MHz measure and 120 KHz for 30 MHz to 1GHz measure. 4.4. Test Result From 9KHz to 30MHz: Test Date : 2025.3.17 Temperature : 26 Test Engineer : Felix Pang Humidity : 54% Test Mode : NFC Test Results : PASS Note: 1. The test results are listed in next pages. 2. This mode is worst case mode, so this report only reflected the worst mode. 3. If the limits for the measurement with the average detector are met when using a receiver with a peak detector, the test unit shall be deemed to meet both limits and the measurement with the quasi-peak detector need not be carried out. Test Frequency: 9KHz-30MHz Frequency Reading Result Factor Emission Level Limits Margin Detector (MHz) (dBV) (dB) (dBV/m) (dBV/m) (dB) Type 0.635 21.66 20.62 42.28 71.55 -29.27 QP 1.438 15.78 20.74 36.52 64.33 -27.81 QP 1.618 16.15 20.17 36.32 63.42 -27.1 QP 3.235 16.14 20.41 36.55 69.54 -32.99 QP 6.637 17.64 20.61 38.25 69.54 -31.29 QP 19.143 18.14 19.18 37.32 69.54 -32.22 QP Remark: Factor = Antenna Factor + Cable Loss Pre-amplifier. Margin = Absolute Level Limit Note: Distance extrapolation factor =40log(Specific distance/ test distance)( dB); Limit line=Specific limits(dBuV) + distance extrapolation factor. Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 14 of 29 Report No.: psi2503155-C01-R03 From 30MHz to 1000MHz: Test Date : 2025.3.17 Temperature : 26 Test Engineer : Felix Pang Humidity : 54% Test Mode : NFC Test Results : PASS 1. The test results are listed in next pages. 2. If the limits for the measurement with the average detector are met when using a Note: receiver with a peak detector, the test unit shall be deemed to meet both limits and the measurement with the average detector and quasi-peak detector need not be carried out. Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Model: LOCK420-8Z Page 15 of 29 Report No.: psi2503155-C01-R03 Polarization: Vertical Note: Level = Reading + Factor Margin = Level - Limit Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 16 of 29 Report No.: psi2503155-C01-R03 Polarization: Horizontal Note: Level = Reading + Factor Margin = Level - Limit Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Model: LOCK420-4Z Page 17 of 29 Report No.: psi2503155-C01-R03 Polarization: Vertical Note: Level = Reading + Factor Margin = Level - Limit Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 18 of 29 Report No.: psi2503155-C01-R03 Polarization: Horizontal Note: Level = Reading + Factor Margin = Level - Limit Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 19 of 29 Report No.: psi2503155-C01-R03 Field Strength Emissions Result Temperature 24oC Relative Humidity 56% Test Mode NFC Note: 1: 30m to 3m correction factor calculation: 40*Log(30m/3m)=40 2: --Means other frequency and mode comply with standard requirements and at least have 20dB margin. 3: Correct Factor=Cable Loss+ Antenna Factor- Amplifier Gain Measurement Result=Reading + Correct Factor Margin=Measurement Result-Limit Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 20 of 29 Report No.: psi2503155-C01-R03 5. Frequency stability 5.1. Test limit Please refer section RSS 210 B.6 & 15.225e. Regulation 15.225(e) The frequency tolerance of the carrier signal shall be maintained within +/-0.01%(±100 ppm) of the operating frequency over a temperature variation of 20 degrees to +50 degrees C at normal supply voltage, and for a variation in the primary supply voltage from 85% to 115% of the rated supply voltage at a temperature of 20 degrees C. For battery operated equipment, the equipment tests shall be performed using a new battery. 5.2. Test Procedure The following equipment are installed on the emission measurement to meet the commission requirements and operating regulations in a manner which tends to maximize its emission characteristics in normal application. 5.3. Test Setup EUT Spectrum Analyzer Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 21 of 29 Report No.: psi2503155-C01-R03 5.4. Test Results Voltage (V) Low DC 10.8V Assigned Frequency(MHz): 13.56MHz Temperature Measured Frequency (MHz) Frequency stability (MHz) +20 13.560162 0.000162 -10 13.560167 0.000167 -5 13.560166 0.000166 0 13.560180 0.000180 Normal DC 12V +10 +20 +30 13.560154 13.560180 13.560154 0.000154 0.000180 0.000154 +40 13.560158 0.000158 +50 13.560171 0.000171 High DC 13.2V Results: Pass +60 +20 13.560171 13.560165 0.000171 0.000165 Limit ±100 ppm ±0.001356MHz Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 22 of 29 Report No.: psi2503155-C01-R03 6. Power Line Conducted Emissions 6.1. Block Diagram of Test Setup PC System Receiver 80cm EUT :50 Terminator LISN 0.8m LISN 6.2. Limit Maximum RF Line Voltage Frequency Quasi-Peak Level dB(V) Average Level dB(V) 150kHz ~ 500kHz 66 ~ 56* 56 ~ 46* 500kHz ~ 5MHz 56 46 5MHz ~ 30MHz 60 50 Notes: 1. * Decreasing linearly with logarithm of frequency. 2. The lower limit shall apply at the transition frequencies. 6.3. Test Procedure (1) The EUT was placed on a non-metallic table, 80cm above the ground plane. (2) Setup the EUT and simulator as shown in 10.1 (3) The EUT Power connected to the power mains through a power adapter and a line impedance stabilization network (L.I.S.N1). The other peripheral devices power cord connected to the power mains through a line impedance stabilization network (L.I.S.N1), this provided a 50-ohm coupling impedance for the EUT (Please refer to the block diagram of the test setup and photographs). Both sides of power line were checked for maximum conducted interference. In order to find the maximum emission, the relative positions of equipments and all of the interface cables were changed according to ANSI C64.10:2013 on conducted Emission test. (4) The bandwidth of test receiver is set at 10KHz. (5) The frequency range from 150 KHz to 30MHz is checked. Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 23 of 29 Report No.: psi2503155-C01-R03 6.4. Test Result Test Date : 2025.3.17 Temperature : 26 Test Engineer : Felix Pang Humidity : 54% Test Mode : NFC Test Results : PASS 1. The test results are listed in next pages. 2. If the limits for the measurement with the average detector are met when using a receiver with a peak detector, the test unit shall be deemed to meet both limits and the Note: measurement with the average detector and quasi-peak detector need not be carried out. 3. If the limits for the measurement with the average detector are met when using a receiver with a quasi-peak detector, the test unit shall be deemed to meet both limits and the measurement with the average detector need not be carried out. Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Model: LOCK420-8Z Page 24 of 29 Report No.: psi2503155-C01-R03 Polarization: L Note: Level = Reading + Factor Margin = Level - Limit Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 25 of 29 Report No.: psi2503155-C01-R03 Polarization: N Note: Level = Reading + Factor Margin = Level - Limit Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Model: LOCK420-4Z Page 26 of 29 Report No.: psi2503155-C01-R03 Polarization: L Note: Level = Reading + Factor Margin = Level - Limit Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 27 of 29 Report No.: psi2503155-C01-R03 Polarization: N Note: Level = Reading + Factor Margin = Level - Limit Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 28 of 29 Report No.: psi2503155-C01-R03 7. Antenna Requirements 7.1. Limit For intentional device, according to RSS-Gen Section 6.8 and FCC 47 CFR Section 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. And according to FCC 47 CFR Section 15.209, if transmitting antennas of directional gain greater than 6dBi are used, the power shall be reduced by the amount in dB that the directional gain of the antenna exceeds 6dBi. 7.2. Antenna Connected Construction The antenna is internal antenna and no consideration of replacement. Please see EUT photo for details. 7.3. Results The EUT antenna is PCB Antenna. It complies with the standard requirement. Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China Page 29 of 29 Report No.: psi2503155-C01-R03 8. Photos of test setup Reference to the appendix I Test Setup Photo for details. 9. Photos of EUT Reference to the appendix II external photos and appendix III internal photos for details. ------ END OF REPORT------ Shenzhen PSI Testing Co., Ltd. Tel: 0755-23011775 | E-mail: [email protected] | http://www.psi-lab.com Add: 1-2/F., Building 5, Yudafu Industrial Park, No.10, Xingye West Road, Shajing Subdistrict, Bao'an District, Shenzhen, Guangdong, China
Related FCC IDs:
- 2AH4J-LOCK420 - Consumer 2.0 Rently Smart Bolt Elite [-LOCK420] WPS 文字