Document DEVICE REPORTGetApplicationAttachment.html?id=7711080Test Report Report No.: MTi240710002-08E1 Date of issue: 2024-08-31 Applicant: Shenzhen Huntkey Electric Co., Ltd. Product name: Q10 Magnetic Power Bank Model(s): HKCPB2710Q1 FCC ID: 2AVYR-HKCPB2710Q1 Shenzhen Microtest Co., Ltd. http://www.mtitest.cn The test report is only used for customer scientific research, teaching, internal quality control and other purposes, and is for internal reference only. Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 2 of 27 Report No.: MTi240710002-08E1 Instructions 1. This test report shall not be partially reproduced without the written consent of the laboratory. 2. The test results in this test report are only responsible for the samples submitted 3. This test report is invalid without the seal and signature of the laboratory. 4. This test report is invalid if transferred, altered, or tampered with in any form without authorization. 5. Any objection to this test report shall be submitted to the laboratory within 15 days from the date of receipt of the report. Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 3 of 27 Report No.: MTi240710002-08E1 Table of contents 1 General Description .........................................................................................................................5 1.1 Description of the EUT...............................................................................................................................5 1.2 Description of test modes ..........................................................................................................................5 1.3 Environmental Conditions..........................................................................................................................6 1.4 Description of support units .......................................................................................................................6 1.5 Measurement uncertainty ..........................................................................................................................6 2 Summary of Test Result ..................................................................................................................7 3 Test Facilities and accreditations ...................................................................................................8 3.1 Test laboratory ...........................................................................................................................................8 4 List of test equipment......................................................................................................................9 5 Evaluation Results (Evaluation)....................................................................................................10 5.1 Antenna requirement ...............................................................................................................................10 6 Radio Spectrum Matter Test Results (RF) .................................................................................... 11 6.1 Conducted Emission at AC power line .................................................................................................... 11 6.2 20dB Occupied Bandwidth ......................................................................................................................14 6.3 Emissions in frequency bands (below 30MHz)........................................................................................18 6.4 Emissions in frequency bands (30MHz - 1GHz)......................................................................................23 Photographs of the test setup .............................................................................................................26 Photographs of the EUT.......................................................................................................................27 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 4 of 27 Report No.: MTi240710002-08E1 Test Result Certification Applicant: Shenzhen Huntkey Electric Co., Ltd. Address: Huntkey Industrial Park, Xue-Xiang Village, Banxue Road, Bantian, Shenzhen, Guangdong, 518129, PEOPLE'S REPUBLIC OF CHINA Manufacturer: Shenzhen Huntkey Electric Co., Ltd. Address: Huntkey Industrial Park, Xue-Xiang Village, Banxue Road, Bantian, Shenzhen, Guangdong, 518129, PEOPLE'S REPUBLIC OF CHINA Product description Product name: Q10 Magnetic Power Bank Trademark: Huntkey Model name: HKCPB2710Q1 Series Model(s): N/A Standards: 47 CFR Part 15C Test Method: ANSI C63.10-2013 Date of Test Date of test: 2024-08-06 to 2024-08-30 Test result: Pass Test Engineer : Reviewed By : Approved By : (Letter Lan) (David Lee) (Leon Chen) Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 5 of 27 Report No.: MTi240710002-08E1 1 General Description 1.1 Description of the EUT Product name: Q10 Magnetic Power Bank Model name: HKCPB2710Q1 Series Model(s): N/A Model difference: N/A Electrical rating: Accessories: Input: DC 5V/3A, 9V/3A Wireless Output: 15W(MAX) USB-C output: DC 5V/3A, 9V/3A Total output: DC 5V/3A Battery: DC 7.2V 5000mAh 36Wh Cable: Type-C to Type-C cable (0.3m) *1 Hardware version: 1.0 Software version: 1.0 Test sample(s) number: MTi240710002-08S1001 RF specification Operating frequency range: Modulation type: 115-205KHz (5W, 7.5W, 10W, 15W) 360kHz (15W) ASK Antenna(s) type: Coil 1.2 Description of test modes No. Emission test modes Mode1 Wireless Output(5W) Mode2 Wireless Output(7.5W) Mode3 Wireless Output(10W) Mode4 Wireless Output(15W)EPP Mode5 Wireless Output(15W)MPP Mode6 Charging +Wireless Output(5W) Mode7 Charging +Wireless Output(7.5W) Mode8 Charging +Wireless Output(10W) Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 6 of 27 Report No.: MTi240710002-08E1 1.3 Environmental Conditions During the measurement the environmental conditions were within the listed ranges: Temperature: 15°C ~ 35°C Humidity: 20% RH ~ 75% RH Atmospheric pressure: 98 kPa ~ 101 kPa 1.4 Description of support units The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests. Support equipment list Description Model Serial No. Manufacturer Adapter EP-TA200 / SAMSUNG wireless charging load wireless charging load YBZ1.1 / / YBZ / Jingxin Wei Support cable list Description Length (m) From To / / / / 1.5 Measurement uncertainty Measurement Conducted emissions (AMN 150kHz~30MHz) Occupied channel bandwidth Radiated spurious emissions (9kHz~30MHz) Radiated spurious emissions (30MHz~1GHz) Temperature Humidity ±3.1dB ±3 % ±4.3dB ±4.7dB ±1 °C ± 5 % Uncertainty This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 7 of 27 2 Summary of Test Result No. Item Standard 1 Antenna requirement 47 CFR Part 15C 2 Conducted Emission at AC power line 47 CFR Part 15C 3 20dB Occupied Bandwidth 47 CFR Part 15C 4 Emissions in frequency bands (below 30MHz) 47 CFR Part 15C 5 Emissions in frequency bands (30MHz - 1GHz) 47 CFR Part 15C Report No.: MTi240710002-08E1 Requirement 47 CFR Part 15.203 Result Pass 47 CFR Part 15.207(a) Pass 47 CFR Part 15.215(c) Pass 47 CFR Part 15.209 Pass 47 CFR Part 15.209 Pass Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 8 of 27 Report No.: MTi240710002-08E1 3 Test Facilities and accreditations 3.1 Test laboratory Test laboratory: Test site location: Telephone: Shenzhen Microtest Co., Ltd. 101, No.7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China (86-755)88850135 Fax: (86-755)88850136 CNAS Registration No.: CNAS L5868 FCC Registration No.: 448573 IC Registration No.: 21760 CABID: CN0093 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 9 of 27 Report No.: MTi240710002-08E1 4 List of test equipment No. Equipment Manufacturer Model Serial No. Cal. date Cal. Due Conducted Emission at AC power line 1 EMI Test Receiver Rohde&schwarz ESCI3 101368 2024-03-20 2025-03-19 2 Artificial mains network Schwarzbeck NSLK 8127 183 2024-03-21 2025-03-20 3 Artificial Mains Network Rohde & Schwarz ESH2-Z5 100263 2024-03-20 2025-03-19 20dB Occupied Bandwidth 1 Wideband Radio Communication Tester Rohde&schwarz CMW500 149155 2024-03-20 2025-03-19 2 ESG Series Analog Ssignal Generator Agilent E4421B GB40051240 2024-03-21 2025-03-20 3 PXA Signal Analyzer Agilent N9030A MY51350296 2024-03-21 2025-03-20 4 Synthesized Sweeper Agilent 83752A 3610A01957 2024-03-21 2025-03-20 5 MXA Signal Analyzer Agilent N9020A MY50143483 2024-03-21 2025-03-20 6 RF Control Unit Tonscend JS0806-1 19D8060152 2024-03-21 2025-03-20 7 Band Reject Filter Group 8 ESG Vector Signal Generator 9 DC Power Supply Tonscend Agilent Agilent JS0806-F N5182A E3632A 19D8060160 2024-03-21 2025-03-20 MY50143762 2024-03-20 2025-03-19 MY40027695 2024-03-21 2025-03-20 Emissions in frequency bands (below 30MHz) 1 EMI Test Receiver Rohde&schwarz ESCI7 101166 2024-03-20 2025-03-19 2 Active Loop Antenna Schwarzbeck FMZB 1519 B 00066 2024-03-23 2025-03-22 3 Amplifier Hewlett-Packard 8447F 3113A06184 2024-03-20 2025-03-19 Emissions in frequency bands (30MHz - 1GHz) 1 EMI Test Receiver Rohde&schwarz ESCI7 101166 2024-03-20 2025-03-19 2 TRILOG Broadband Antenna schwarabeck VULB 9163 9163-1338 2023-06-11 2025-06-10 3 Active Loop Antenna Schwarzbeck FMZB 1519 B 00066 2024-03-23 2025-03-22 4 Amplifier Hewlett-Packard 8447F 3113A06184 2024-03-20 2025-03-19 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 10 of 27 Report No.: MTi240710002-08E1 5 Evaluation Results (Evaluation) 5.1 Antenna requirement Test Requirement: Refer to 47 CFR Part 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this section. 5.1.1 Conclusion: The antenna of the EUT is permanently attached. The EUT complies with the requirement of FCC PART 15.203. Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 11 of 27 Report No.: MTi240710002-08E1 6 Radio Spectrum Matter Test Results (RF) 6.1 Conducted Emission at AC power line Test Requirement: Test Limit: Test Method: Procedure: Except as shown in paragraphs (b)and (c)of this section, for an intentional radiator that is designed to be connected to the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any frequency or frequencies, within the band 150 kHz to 30 MHz, shall not exceed the limits in the following table, as measured using a 50 H/50 ohms line impedance stabilization network (LISN). Frequency of emission (MHz) 0.15-0.5 0.5-5 5-30 Conducted limit (dBV) Quasi-peak Average 66 to 56* 56 to 46* 56 46 60 50 *Decreases with the logarithm of the frequency. ANSI C63.10-2013 section 6.2 Refer to ANSI C63.10-2013 section 6.2, standard test method for ac powerline conducted emissions from unlicensed wireless devices 6.1.1 E.U.T. Operation: Operating Environment: Temperature: 33 °C Humidity: 74.2 % Atmospheric Pressure: 100 kPa Pre test mode: Final test mode: Mode6, Mode7, Mode8 All of the listed pre-test mode were tested, only the data of the worst mode (Mode8) is recorded in the report 6.1.2 Test Setup Diagram: Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] 6.1.3 Test Data: Mode8 / Line: Line / CH: L Page 12 of 27 Report No.: MTi240710002-08E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Mode8 / Line: Neutral / CH: L Page 13 of 27 Report No.: MTi240710002-08E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 14 of 27 Report No.: MTi240710002-08E1 6.2 20dB Occupied Bandwidth Test Requirement: Test Limit: 47 CFR Part 15.215(c) Refer to 47 CFR 15.215(c), intentional radiators operating under the alternative provisions to the general emission limits, as contained in §§ 15.217 through 15.257 and in subpart E of this part, must be designed to ensure that the 20 dB bandwidth of the emission, or whatever bandwidth may otherwise be specified in the specific rule section under which the equipment operates, is contained within the frequency band designated in the rule section under which the equipment is operated. Test Method: Procedure: ANSI C63.10-2013, section 6.9.2 a) The spectrum analyzer center frequency is set to the nominal EUT channel center frequency. The span range for the EMI receiver or spectrum analyzer shall be between two times and five times the OBW. b) The nominal IF filter bandwidth (3 dB RBW) shall be in the range of 1% to 5% of the OBW and video bandwidth (VBW) shall be approximately three times RBW, unless otherwise specified by the applicable requirement. c) Set the reference level of the instrument as required, keeping the signal from exceeding the maximum input mixer level for linear operation. In general, the peak of the spectral envelope shall be more than [10 log (OBW/RBW)] below the reference level. Specific guidance is given in 4.1.5.2. d) Steps a) through c) might require iteration to adjust within the specified tolerances. e) The dynamic range of the instrument at the selected RBW shall be more than 10 dB below the target "-xx dB down" requirement; that is, if the requirement calls for measuring the -20 dB OBW, the instrument noise floor at the selected RBW shall be at least 30 dB below the reference value. f) Set detection mode to peak and trace mode to max hold. g) Determine the reference value: Set the EUT to transmit an unmodulated carrier or modulated signal, as applicable. Allow the trace to stabilize. Set the spectrum analyzer marker to the highest level of the displayed trace (this is the reference value). h) Determine the "-xx dB down amplitude" using [(reference value) - xx]. Alternatively, this calculation may be made by using the marker-delta function of the instrument. i) If the reference value is determined by an unmodulated carrier, then turn the EUT modulation ON, and either clear the existing trace or start a new trace on the spectrum analyzer and allow the new trace to stabilize. Otherwise, the trace from step g) shall be used for step j). j) Place two markers, one at the lowest frequency and the other at the highest frequency of the envelope of the spectral display, such that each marker is at or slightly below the "-xx dB down amplitude" determined in step h). If a marker is below this "-xx dB down amplitude" value, then it shall be as close as possible to this value. The occupied bandwidth is the frequency difference between the two markers. Alternatively, set a marker at the lowest frequency of the envelope of the spectral display, such that the marker is at or slightly below the "-xx dB down amplitude" determined in step h). Reset the markerdelta function and move the marker to the other side of the emission until the delta marker amplitude is at the same level as the reference marker amplitude. The marker-delta frequency reading at this point is the specified emission bandwidth. k) The occupied bandwidth shall be reported by providing plot(s) of the measuring instrument display; the plot axes and the scale units per division shall be clearly labeled. Tabular data may be reported in addition to the plot(s). Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 15 of 27 Report No.: MTi240710002-08E1 6.2.1 E.U.T. Operation: Operating Environment: Temperature: 27.3 °C Humidity: 72.9 % Atmospheric Pressure: 100 kPa Pre test mode: Mode1, Mode2, Mode3, Mode4, Mode5, Mode6, Mode7, Mode8 Final test mode: All of the listed pre-test mode were tested, only the data of the worst mode (Mode4, Mode5, Mode6, Mode7, Mode8) is recorded in the report 6.2.2 Test Setup Diagram: Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 16 of 27 Report No.: MTi240710002-08E1 6.2.3 Test Data: Note: Because the measured signal is CW-like, adjusting the RBW per C63.10 would not be practical since measurement bandwidth will always follow the RBW. The RBW is set to 300 Hz to perform the occupied bandwidth test. Phone 15W (115kHz 205kHz) Frequency kHz 20 dB occupied bandwidth Hz 99% occupied bandwidth Hz 128.210 812 690 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 17 of 27 Report No.: MTi240710002-08E1 Note: Because the measured signal is CW-like, adjusting the RBW per C63.10 would not be practical since measurement bandwidth will always follow the RBW. The RBW is set to 300 Hz to perform the occupied bandwidth test. Phone 15W (360kHz) Frequency kHz 20 dB occupied bandwidth Hz 99% occupied bandwidth Hz 360.540 819 707 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 18 of 27 Report No.: MTi240710002-08E1 6.3 Emissions in frequency bands (below 30MHz) Test Requirement: Test Limit: Test Method: Procedure: 47 CFR Part 15.209 Frequency (MHz) 0.009-0.490 0.490-1.705 1.705-30.0 30-88 88-216 216-960 Above 960 Field strength (microvolts/meter) 2400/F(kHz) 24000/F(kHz) 30 100 ** 150 ** 200 ** 500 Measuremen t distance (meters) 300 30 30 3 3 3 3 ** Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz. However, operation within these frequency bands is permitted under other sections of this part, e.g., §§ 15.231 and 15.241. In the emission table above, the tighter limit applies at the band edges. The emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 990 kHz, 110490 kHz and above 1000 MHz. Radiated emission limits in these three bands are based on measurements employing an average detector. As shown in § 15.35(b), for frequencies above 1000 MHz, the field strength limits in paragraphs (a)and (b)of this section are based on average limits. However, the peak field strength of any emission shall not exceed the maximum permitted average limits specified above by more than 20 dB under any condition of modulation. For point-to-point operation under paragraph (b)of this section, the peak field strength shall not exceed 2500 millivolts/meter at 3 meters along the antenna azimuth. ANSI C63.10-2013 section 6.4 ANSI C63.10-2013 section 6.4 6.3.1 E.U.T. Operation: Operating Environment: Temperature: 22.5 °C Humidity: 43 % Atmospheric Pressure: 101 kPa Pre test mode: Mode1, Mode2, Mode3, Mode4, Mode5, Mode6, Mode7, Mode8 Final test mode: All of the listed pre-test mode were tested, only the data of the worst mode (Mode4, Mode5, Mode6, Mode7, Mode8) is recorded in the report 6.3.2 Test Setup Diagram: Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] 6.3.3 Test Data: Mode4 / Polarization: Coplanar Page 19 of 27 Report No.: MTi240710002-08E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Mode4 / Polarization: Coaxial Page 20 of 27 Report No.: MTi240710002-08E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Mode5 / Polarization: Coplanar Page 21 of 27 Report No.: MTi240710002-08E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Mode5 / Polarization: Coaxial Page 22 of 27 Report No.: MTi240710002-08E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Page 23 of 27 Report No.: MTi240710002-08E1 6.4 Emissions in frequency bands (30MHz - 1GHz) Test Requirement: Test Limit: Test Method: Procedure: 47 CFR Part 15.209 Frequency (MHz) 0.009-0.490 0.490-1.705 1.705-30.0 30-88 88-216 216-960 Above 960 Field strength (microvolts/meter) 2400/F(kHz) 24000/F(kHz) 30 100 ** 150 ** 200 ** 500 Measuremen t distance (meters) 300 30 30 3 3 3 3 ** Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz. However, operation within these frequency bands is permitted under other sections of this part, e.g., §§ 15.231 and 15.241. In the emission table above, the tighter limit applies at the band edges. The emission limits shown in the above table are based on measurements employing a CISPR quasi-peak detector except for the frequency bands 990 kHz, 110490 kHz and above 1000 MHz. Radiated emission limits in these three bands are based on measurements employing an average detector. As shown in § 15.35(b), for frequencies above 1000 MHz, the field strength limits in paragraphs (a)and (b)of this section are based on average limits. However, the peak field strength of any emission shall not exceed the maximum permitted average limits specified above by more than 20 dB under any condition of modulation. For point-to-point operation under paragraph (b)of this section, the peak field strength shall not exceed 2500 millivolts/meter at 3 meters along the antenna azimuth. ANSI C63.10-2013 section 6.5 ANSI C63.10-2013 section 6.5 6.4.1 E.U.T. Operation: Operating Environment: Temperature: 26 °C Humidity: 54 % Atmospheric Pressure: 98.3 kPa Pre test mode: Mode1, Mode2, Mode3, Mode4, Mode5, Mode6, Mode7, Mode8 Final test mode: All of the listed pre-test mode were tested, only the data of the worst mode (Mode5, Mode6, Mode7, Mode8) is recorded in the report 6.4.2 Test Setup Diagram: Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] 6.4.3 Test Data: Mode5 / Polarization: Horizontal / CH: L Page 24 of 27 Report No.: MTi240710002-08E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Mode5 / Polarization: Vertical / CH: L Page 25 of 27 Report No.: MTi240710002-08E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Photographs of the test setup Refer to Appendix - Test Setup Photos Page 26 of 27 Report No.: MTi240710002-08E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected] Photographs of the EUT Refer to Appendix - EUT Photos Page 27 of 27 ----End of Report---- Report No.: MTi240710002-08E1 Address: 101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China. Tel: 0755-88850135-1439 Mobile: 131-4343-1439 (Wechat same number) Web: http://www.mtitest.cn E-mail: [email protected]
Related FCC IDs:
- 2AVYR-HKCPB2710Q1 - Shenzhen Huntkey Electric Co., Ltd Q10 Magnetic Power Bank [-HKCPB2710Q1] Microsoft Word 2016