Identification
OpenWay® Riva Socket Based Router User Guide 18 April 2018 DRAFT
Copyright
© 2018 Itron, Inc. All rights reserved.
Confidentiality Notice
The information contained herein is proprietary and confidential and is being provided subject to the condition that (i) it be held in confidence except to the extent required otherwise by law and (ii) it will be used only for the purposes described herein. Any third party that is given access to this information shall be similarly bound in writing.
Trademark Notice
Itron is a registered trademark of Itron, Inc. All other product names and logos in this documentation are used for identification purposes only and may be trademarks or registered trademarks of their respective companies.
Suggestions
For more information about Itron or Itron products, see www.itron.com. If you have questions or comments about the software or hardware product, contact Itron Technical Support Services.
Contact
· Email: [email protected] · Internet: support.itron.com · Telephone Itron Technical Support North America: 1-877-487-6602 For technical support contact information by region, go to www.itron.com and select your country and language.

Contents

Chapter 1 Important Product and Compliance Information............................1
FCC Compliance...................................................................................................................................................1 Factory Repair of Meters...................................................................................................................................... 2 Battery...................................................................................................................................................................3 Standards..............................................................................................................................................................3

Chapter 2 General............................................................................................... 4
Overview............................................................................................................................................................... 4 Architecture...........................................................................................................................................................4 Packaging............................................................................................................................................................. 5

Chapter 3 Physical Description..........................................................................6
Router Box............................................................................................................................................................ 7 Base Meter............................................................................................................................................................8

Chapter 4 Specifications.................................................................................. 11
Operating Environment....................................................................................................................................... 11 Electrical............................................................................................................................................................. 11 Dimensions......................................................................................................................................................... 11 Shipping Weights................................................................................................................................................ 11

Chapter 5 Installation........................................................................................13
Base Meter..........................................................................................................................................................13 Safety....................................................................................................................................................... 13 Unpacking and Inspection....................................................................................................................... 13 Battery......................................................................................................................................................14 Selecting a Site........................................................................................................................................ 14
Router Box.......................................................................................................................................................... 14 Unpacking and Inspection....................................................................................................................... 14 Storage.....................................................................................................................................................14 Selecting a Site........................................................................................................................................ 15 Mounting the Router Box to the Base Meter........................................................................................... 15 Connecting the Router to the Base Meter............................................................................................... 16

Chapter 6 Configuration................................................................................... 18
Initial Setup......................................................................................................................................................... 18 Login........................................................................................................................................................ 18 SBR Configuration Script.........................................................................................................................18 Changing Hostname................................................................................................................................ 19 C1222 Relay.............................................................................................................................................19 LTE Connection Manager.........................................................................................................................20 System Configuration...............................................................................................................................20 Enabling Itron Service(s)...........................................................................................................................21
Configuration and Monitoring............................................................................................................................. 21

TDC-xxxx-xxx DRAFT

iii

Proprietary and Confidential

Installing Advanced REST Client Chrome Web App................................................................................ 22 ARC Setup............................................................................................................................................... 22 Using ARC................................................................................................................................................22
GET Request Using ARC.................................................................................................................. 22 PUT Request Using ARC.................................................................................................................. 23 Changing Master Relay Address...................................................................................................... 24 Changing APN.................................................................................................................................. 25
Chapter 7 Operation..........................................................................................27
LEDs....................................................................................................................................................................27 System LED..............................................................................................................................................28 Battery LED.............................................................................................................................................. 28
Events................................................................................................................................................................. 28 Alarms................................................................................................................................................................. 28 List of Alarms...................................................................................................................................................... 29

TDC-xxxx-xxx DRAFT

iv

Proprietary and Confidential

Chapter 1 Important Product and Compliance Information

FCC Compliance

Labeling
The following information appears on labels on the exterior of the SBR.
· FCC ID: SK9OW1
· FCC ID: SK9ITR9002
· FCC ID: SK9WF111
· FCC ID: N7NEM7455
The following information may also appear on an exterior label.
"This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation."
FCC Part 15, Class B
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
· Reorient or relocate the receiving antenna.
· Increase the separation between the equipment and receiver.
· Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
· Consult the dealer or an experienced radio/TV technician for help.
Note: Changes or modifications to this device not expressly approved by Itron, Inc. could void the user's authority to operate the equipment.

TDC-xxxx-xxx DRAFT

1

Proprietary and Confidential

Important Product and Compliance Information
RF Exposure
The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.
Professional Installation
These antennas are intended for professional installation by the integrator. The OEM integrator is still responsible for the FCC compliance requirement of the end product, which integrates this antenna.
Modification and Repairs
To ensure FCC compliance and system performance, this device, antenna, and/or coaxial assembly shall not be changed or modified without the express written approval of Itron. Any unauthorized modification will void the user's authority to operate the equipment.
This device contains no user serviceable parts. Attempts to repair this device by unauthorized personnel may subject the person to shock hazard if removal of protected covers is attempted. Unauthorized repair will void the warranty and/or maintenance contract with your company.
Factory Repair of Meters
Itron recommends that all repairs be performed at the factory. Certain repairs may be performed by the user; however, unauthorized repairs will cause any existing warranty to be void.
Repair of Meters Under Warranty If the meter is under warranty and has failed due to components or workmanship, then Itron, Inc. will repair the meter at no charge. A return authorization number must be obtained before the equipment can be sent back to the factory. Contact your Itron Sales Representative for assistance.
Repair of Meters Not Under Warranty The same procedure as above applies. Itron will charge for the necessary repairs based on the failure.
Service Return Address Itron, Inc. Customer Repair Department 313 North Highway 11 Dock C West Union, SC 29696

TDC-xxxx-xxx DRAFT

2

Proprietary and Confidential

Battery

Important Product and Compliance Information

The OpenWay Riva CENTRON meter contains a battery that powers the clock circuit during a power outage. The battery is permanently soldered to the module and is expected to last the life of the meter.
Caution: The product you have purchased contains a recyclable battery. At the end of its useful life, under various state and local laws, it may be illegal to dispose of this battery into the municipal waste stream. Check with your local area solid waste officials for details about recycling options or proper disposal.

Standards

Regulatory Compliance: · FCC Part 15.247 · FCC Part 15 Class B · FCC Part 2.1091 Standards Compliance: · ANSI C12.1 - 2008 · ANSI C12.20 (Class 0.5) ­ 2010 (socket based only) · ANSI 62.45 - 1992 · IEC 61000-4-4-2004-07 · IEC 61000-4-2-2001-04

TDC-xxxx-xxx DRAFT

3

Proprietary and Confidential

Chapter 2 General
Overview
The Socket Based Router (SBR) is an OpenWay networking device whose software and hardware are designed to route and forward information and to connect two or more logical subnets (which do not necessarily map one-to-one to the physical interfaces of the router). In other words, the SBR incorporates traditional router functionality in addition to relay characteristics.
The Socket Based Router combines the existing cell relay functionality with the capability to serve as an Internet Protocol (IP) network router. The SBR includes the capability to perform the wrapping and unwrapping of the different IP versions. The SBR is a high capacity OpenWay solution capable of simultaneous support of Wide Area Networks (WAN), Remote Area Networks (RAN), and Local Area Networks (LAN).
The SBR provides dual-mesh network support by supporting both RFLAN and OpenWay Riva mesh networks simultaneously while maintaining full cell relay functionality between RFLAN meters. The SBR also improves OpenWay Riva mesh network by serving as a gateway for distribution automation and adding new devices and applications such as OpenWay Riva gas and water metering, streetlights, and future active grid applications including Distributed Intelligence. Adaptive Communications Technology (ACT) for network communications and distributed intelligence applications enables the SBR to support various modulation rates with automatic selection of optimal data rates.
Using an independent base meter along with a specially designed router enclosure allows the utility more flexibility with inventory management and field support. The SBR can be serviced or replaced without disrupting meter service. The base meter remains in place during field activities. The base meter uses a standard 2S form meter socket (either ring or ringless).
Local access to the Socket Based Router is through secure Wifi. The Socket Based Router is also accessible using SSH/Telnet through Port 22. Base meter local access is through either zigbee or the optical port. Backhaul communications are with 4G/LTE cellular with backward compatibility to 3G.
The Socket Based Router is designed with two field-replaceable battery packs that provide up to 8 hours of hold-up time. In addition, these dual battery packs permit automated battery health checks.
Architecture

TDC-xxxx-xxx DRAFT

4

Proprietary and Confidential

General

Packaging
The SBR is designed to deliver high performance in a variety of outdoor environments. SBR packaging takes into consideration utility power meter attachment restrictions within the allowed communications space parameters.

TDC-xxxx-xxx DRAFT

5

Proprietary and Confidential

Chapter 3 Physical Description
The Socket Based Router product is comprised of two primary hardware components: the router with its housing and the base meter. When assembled the Socket Based Router becomes one unit as shown below.

TDC-xxxx-xxx DRAFT

6

Proprietary and Confidential

Table :
Callout 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Router Box

Physical Description
Description Monopod WiFi Antenna RFLAN Connector 4G/LTE Module RFLAN Module LTE1 RF Connector LTE2 RF Connector LTE1 Antenna RFLAN 900MHz Antenna Viewing Window LTE2 Antenna OW Riva 900MHz CAM Antenna Backup Battery Additional Backup Battery Slot Base Meter Base Meter to Router Box Connector OpenWay Riva Module

The Socket Based Router enclosure is a weathertight box specially designed to protect the router components and to attach a Base Meter. This Base Meter is a Form 2S meter that has special lugs and a connector built into the outer cover for mounting the Router Box and a connector to connect the Base Meter to the router.

TDC-xxxx-xxx DRAFT

7

Proprietary and Confidential

Physical Description

Base Meter
This Base Meter is a Form 2S meter that has special lugs built into the outer cover for mounting the Router Box and a connector to connect the Base Meter to the router. The Base meter is an ITRD device based on the HW3.5 OpenWay meter.

TDC-xxxx-xxx DRAFT

8

Proprietary and Confidential

Physical Description

TDC-xxxx-xxx DRAFT

9

Proprietary and Confidential

Physical Description
The Base Meter also includes a custom AC-DC primary power supply board with isolated 19V outputs. This provides serial port isolation and pass-through between the register and
the Socket Based Router.

TDC-xxxx-xxx DRAFT

10

Proprietary and Confidential

Chapter 4 Specifications

Operating Environment

Table :
Parameter Temperature, Base Meter Temperature, Modem Humidity
Electrical

Description -40°C to +85°C (-40°F to +185°F) -30°C to +65°C (-22°F to +149°F) 0% to 95% non-condensing

Table :
Parameter Voltage Input Frequency Burden (total burden for meter and router)
Dimensions

Description 240 VAC (+/- 20% at 60 Hz) (+/- 10% at 50 Hz) 60 Hz (50 Hz) 14.7 Watts

Table : Router Box

Parameter Height Width Depth Table : Base Meter

Description 10.8 inches (27.4cm) 11 inches (30.0cm) 7.5 inches (19.1cm)

Parameter Height Width Depth

Description 6.95 inches (17.66cm) 6.95 inches (17.66cm) 5.5 inches (13.97cm)

Shipping Weights

TDC-xxxx-xxx DRAFT

11

Proprietary and Confidential

Specifications
Table : Router Box
Parameter 15 lbs(6.8 kg) Table : Base Meter
Parameter 11 lbs (4.99kg)

Description 4 units with shipping carton
Description with battery and shipping box

TDC-xxxx-xxx DRAFT

12

Proprietary and Confidential

Chapter 5 Installation

The Base Meter used with the Socket Based Router may be installed and powered up prior to the installation of the Router Box. Base Meter installation must be compliant with the generally accepted technical rules for the installation of electrical and telecommunication equipment valid in your jurisdiction. This feature allows the Router Box to be installed, serviced or exchanged without disrupting power to the residence.
Base Meter

Safety
Meter installation must be compliant with the generally accepted technical rules for the installation of electrical and telecommunication equipment valid in your jurisdiction.
The electrical utility dictates the safety procedures for meter installations. Please check with the local electrical utility for these safety procedures.
Install the meter in accordance with the voltage and current specifications printed on the front panel and the wire and environmental specifications given in the installation information.
Do not install the meter if it is damaged.
Do not install the meter if it has been dropped or otherwise subjected to significant impact even if no damage can be seen.
Do not use the meter for primary protection purposes.
Unpacking and Inspection
Be sure you are working in a static-free environment; electrostatic discharge (ESD) can damage meter components.
Upon receipt:
· Check the condition of the packaging to ensure there was no damage during shipment. · Verify that the packaging label matches the order. · Inspect for obvious damage to the cover, base, and meter assembly. · Compare the meter and register nameplates to the record card and invoice. Verify the
type, class, voltage, form number, and other pertinent data. · Verify that the Itron meter seals are in place.
As with all precision electronic instruments, the meter should be handled with care. Follow these precautions when handling the meter:

TDC-xxxx-xxx DRAFT

13

Proprietary and Confidential

Installation
· Avoid damaging the meter base, cover, reset mechanism (if supplied), and optical connector (if supplied).
· When handling modules, grip the circuit board by its edges. Do not touch the liquid crystal display.
· Save the original packing materials.
Battery
The OpenWay Riva CENTRON meter contains a battery that powers the clock circuit during a power outage. The battery is permanently soldered to the module and is expected to last the life of the meter.
Caution: The product you have purchased contains a recyclable battery. At the end of its useful life, under various state and local laws, it may be illegal to dispose of this battery into the municipal waste stream. Check with your local area solid waste officials for details about recycling options or proper disposal.
Selecting a Site
The meter is designed and manufactured to be installed in an environment with an operating temperature range between -40°C and +85°C (-40°F to +185°F).
Router Box

Unpacking and Inspection

Upon receipt: · Check the condition of the packaging to ensure there was no damage during shipment. · Verify that the packaging label matches your order. · Inspect for obvious damage to the device. · Compare the nameplates to the record card and invoice. Verify the pertinent data. · Verify that the unit seals are in place. · Save the original packing materials.
Storage

Store the Socket Based Router in a clean, dry environment which meets the specifications detailed in the Specifications chapter of this document. Avoid prolonged storage (more than

TDC-xxxx-xxx DRAFT

14

Proprietary and Confidential

Installation
one year) at temperatures above +70°C (+158°F). Store the unit in the original packing material.
Selecting a Site
The Socket Based Router is intended for outdoor installation with an operating temperature range between -40°C and +85°C (-40°F to +185°F). Operation in moderate temperatures increases reliability and product life.
Mounting the Router Box to the Base Meter
The base meter is fitted with three threaded lugs on the outer cover to receive the three screws that are captive to the router box. The outer cover also contains one electrical connector for the router box cable.

Callout 1 2

Description Electrical connector Screw mounting lugs

TDC-xxxx-xxx DRAFT

15

Proprietary and Confidential

Installation

Callout 1 2

Description Router box connector cable Captive mounting screws

Connecting the Router to the Base Meter

Insert the cable from the router into plug on the face of the base meter to make the electrical connection between the router box and base meter.

TDC-xxxx-xxx DRAFT

16

Proprietary and Confidential

Installation

TDC-xxxx-xxx DRAFT

17

Proprietary and Confidential

Chapter 6 Configuration
Initial Setup
This section assumes that the SBR Customer configuration is not loaded by the factory. This is meant for initial SBR Evaluation samples setup, only. For changes following initial setup, use the HTTP interface with Advanced REST Client (ARC) tool in the Configuration and Monitoring section.
Login
An SSH server is available for the user to connect to the SBR. To connect to the SBR using WiFi setup a hotspot using the configured SSID/Password given with customer shipment information. After which you can SSH into the SBR with the provision IP from the hotspot. ior login via serial console. A serial console (UART0) is also enabled. Table : Example
Ubuntu 16.04.3 LTS sbr-0-3-8 ttyS0 sbr-0-3-8 login:_ On both interfaces, the username isitron and the password is provided on customer shipment information. Table : Example
Last login: Fri Nov 10 13:18:33 EST 2017 from 172.17.212.30 on pts/1 Welcome to Ubuntu 16.04.3 LTS (GNU/Linux 4.10.0-37-generic x86_64) * Documentation: https://help.ubuntu.com * Management: https://landscape.canonical.com * Support: https://ubuntu.com/advantage 48 packages can be updated. 23 updates are security updates.
itron@sbr-0-3-8:~$ _
SBR Configuration Script
The SBR includes a configuration script which allows the user the edit various configuration variables. By default, it is in /home/itron/sbrconfig.sh and can only be run as root or with sudo.

TDC-xxxx-xxx DRAFT

18

Proprietary and Confidential

Changing Hostname

Configuration

To change the hostname, run sbrconfig script: sudo ./sbrconfig.sh hostname <your hostname>
Table : Example
itron@sbr-0-3-8:~$ sudo ./sbrconfig.sh hostname sbr-test123-0-3-8 Parameter Count 2 Set the hostname of the SBR to sbr-test123-0-3-8 Parameter Count 1 hostname is set to sbr-test123-0-3-8
Reboot the SBR for the changes to be applied. sudo reboot
C1222 Relay

The following c1222relayConfigure variables can be changed using the sbrconfig script. i) SBR ESN
sudo ./sbrconfig.sh esn <your esn here> Table : Example
itron@sbr-test123-0-3-8:~$ sudo ./sbrconfig.sh esn your.esn.here Parameter Count 2
Set the Electronic Serial Number your.esn.here Setting ESN to your.esn.here ii) Collection Engine IP address
sudo ./sbrconfig.sh master_relay_address <CE IP address> Table : Example
itron@sbr-test123-0-3-8:~$ sudo ./sbrconfig.sh master_relay_address your.master.relay.address your.master.relay.address Parameter Count 2 Set Master Relay Address your.master.relay.address Setting master relay to your.master.relay.address iii) Base Meter ESN
sudo ./sbrconfig.sh vcm_mac <BM ESN>

TDC-xxxx-xxx DRAFT

19

Proprietary and Confidential

Configuration
Table : Example
itron@sbr-test123-0-3-8:~$ sudo ./sbrconfig.sh vcm_mac 123456789 Parameter Count 2 Set the virtural comm MAC address to 123456789 VCM MAC to 123456789 RFLAN UID
sudo ./sbrconfig.sh utility_id <Utility ID> Table : Example
itron@sbr-test123-0-3-8:~$ sudo ./sbrconfig.sh utility_id ff Parameter Count 2 Set the Utility ID to ff RFLAN COM UID set to ff C1222 Relay Daemon PID 1611 SetUtilityID: OK Modem Reset Scheduled comm module reset. Takes about 1 minute to complete.
LTE Connection Manager
The following Connection Manager Configure variables can be changed using the sbrconfig script. i) APN
sudo ./sbrconfig.sh apn <cellular provider Access Point Name> Table : Example
itron@sbr-test123-0-3-8:~$ sudo ./sbrconfig.sh apn your.apn.here Parameter Count 2 Set the APN to your.apn.here apn your.apn.here
System Configuration
The following System Configure variables can be changed using the sbrconfig script. i) NTP Server
sudo ./sbrconfig.sh ntp_config <NTP Server IP address>

TDC-xxxx-xxx DRAFT

20

Proprietary and Confidential

Table : Example

Configuration

itron@sbr-test123-0-3-8:~$ sudo ./sbrconfig.sh ntp_config your.ntp.server Parameter Count 2 NTP Configuration your.ntp.server Setting NTP Server to your.ntp.server
ii) External Syslog Server
sudo ./sbrconfig.sh syslog_server <Syslog server IP address>
Table : Example

itron@sbr-test123-0-3-8:~$sudo ./sbrconfig.sh syslog_server your.syslog.server Parameter Count 2 syslog Server Address your.syslog.server Setting Syslog Server to your.syslog.server

Enabling Itron Service(s)

Enable mctrld
sudo systemctl enable mctrld
Start mctrld
sudo systemctl start mctrld
Table : Example
itron@sbr-test123-0-3-8:~$ sudo systemctl enable mctrld mctrld.service is not a native service, redirecting to systemd-sysv-install Executing /lib/systemd/systemd-sysv-install enable mctrld itron@sbr-test123-0-3-8:~$ sudo systemctl start mctrld
The SBR will then connect to the LTE network and register to the CE. After this point, you can use the HTTP interface with ARC for monitoring and to make any additional configuration changes which are listed in the Configuration and Monitoring section.
Note: For certain configuration item(s) like SBR ESN, Base Meter ESN, APN, a system reboot is required for the changes to take effect. This may be required after changing Test Environments, if not handled by runtime configuration changes in the Configuration and Monitoring section.
Configuration and Monitoring
The RESTful Web Services client, i.e. ARC, should only be used after Itron services have been enabled and started as described in the SBR Configuration Script section.

TDC-xxxx-xxx DRAFT

21

Proprietary and Confidential

Configuration
Installing Advanced REST Client Chrome Web App
a) https://advancedrestclient.com/

b) Hit the GET IT NOW or GET THE APP button the website and once redirected to the chrome web store add it to chrome.

ARC Setup
Please, ensure HTTP "Content-Type" header is set to "application/json", as shown below before continuing.
Using ARC
GET Request Using ARC
i) Enter the URL for the information you would like (green box) and hit the send button to the right (orange box). The information (black box) will then be displayed.

TDC-xxxx-xxx DRAFT

22

Proprietary and Confidential

Configuration

PUT Request Using ARC
ii) Generally, you do a PUT request after a GET request this follows that logic.
iii) Enter IP address (green box).
iv) Select the Body tab (blue box) then ensure that Body content type is "application/json" and Editor view is "Text input".
v) Insert the option you wish to change (red box) using the same format as the output from the GET request (black box). Ensuring that the text in the body is in the format: {"option":"option"}
vi) Once the change is formatted correctly you can hit send (orange box).

TDC-xxxx-xxx DRAFT

23

Proprietary and Confidential

Configuration

vii) After which point the output (black) will change to "Success!" if the put request was successfully executed.

Changing Master Relay Address

i) Run a get request on http://your.ip.address/itron/c1222 to get current information on C1222 Relay.
ii) To change the Master Relay Address, follow the same procedure as the used in the PUT request example in the previous paragraph.
iii) Enter the information (red box) in the same layout as received by the GET request (black box).

TDC-xxxx-xxx DRAFT

24

Proprietary and Confidential

Configuration
iv) After submitting the PUT request, you should see the "Success!" message if put request was successfully executed.

Changing APN
You must use the Wifi interface to change the APN using ARC, as the cellular connection drops when the APN is changed.
i) Run a GET request on http://your.wifi.ip.address/itron/modem to get current information about the modem interface.

TDC-xxxx-xxx DRAFT

25

Proprietary and Confidential

Configuration
ii) To change APN, follow the same procedure as the used in the PUT request example.
iii) Enter the information (red box) in the same layout as received by the GET request (black box).
iv) Submit Put request on the APN (orange box).
v) After submitting the PUT request, you should see the "Success!" message if put request was successfully executed.

Reboot the SBR for the changes to be applied, doing so by SSHing into the SBR using the wifi interface.
i) sudo reboot

TDC-xxxx-xxx DRAFT

26

Proprietary and Confidential

Chapter 7 Operation
LEDs
The socket based router provides several LEDs to indicate the status of key elements in the router.

Table : Router LED
Callout 1 2 3 4 5

Description Battery 1 Battery 2 DC In System LED Key E1

TDC-xxxx-xxx DRAFT

27

Proprietary and Confidential

Operation
Callout 6 7 8 9 10 11 12 13
System LED

Description Key E2 LTE WiFi Vcc USB ACT Ready HDD Vcc 3.3V Vcc 5V

The Socket Based Router contains two System LEDs: one internal to the router and one located externally on the bottom left corner of the router box. The external LED provides a view of the router status without the need to open the router box. The states of the external LED mirror the states of the internal LED. The possible SYSLED states are
· Blink Red: C12.22 relay started, trying to establish a TCP connection to the CE
· Blink Green: TCP communication OK, registration with CE in progress
· Green: Registered with CE · Red: Error (No CE communication, no backhaul, no RFLAN module...
Battery LED

The Socket Based Router contains two battery LEDs; one for each battery. If the Socket Based Router is configured with either one or two batteries, the LED states are:
· Green: OK · Alternate Green/Red (blink): Battery below warning capacity threshold · Red: Battery below critical capacity threshold
If the Socket Based Router is configured with: · only one battery the LED for the second battery LED will be in the off state. · two batteries and one is missing, the corresponding LED will be in the red state

Events

All generated events are managed by the local syslog. This behavior cannot be changed. A configuration item allows the events to duplicated and sent to a remote server: syslog_server
Alarms

TDC-xxxx-xxx DRAFT

28

Proprietary and Confidential

Operation
Alarms are generated by Itron services. Itron Services monitor several parameters to ensure the proper operation of the SBR. When an alarm is asserted, the services call a shell script: sbr-alarm with an "alarm_on" parameter to signal the alarm. When an alarm is turned off, the alarm script is also called with "alarm_off". Every minute, if an alarm is still present, the alarm script is called as a redundancy measure. Discrimination of new alarms and redundancies is performed using an alarm counter that is only incremented when an alarm is new. There is one alarm counter per alarm type. Counters can be reset through the HTTPS API. The default behavior of the alarm script is the following. 1. Log a generic message in the local syslog. 2. Perform one or several action(s) related to the specific alarm, if necessary. Furthermore, a configuration item allows the generic events to be duplicated and sent to a remote syslog server: alarm_server. This default behavior can be changed by modifying the sbr-alarm script, without the need to rebuild the Itron binaries. The alarm script syntax is the following:
sbr-alarm <alarm_name> <alarm_on|alarm_off> <value_or_state> <counter>  The generated events have the following characteristics: · Priority: o Alarm ON: daemon.warning o Alarm OFF: daemon.notice · Tag: sbr-alarm · Value: Alarm: ON/OFF - Condition: <alarm_name> - Value: <value_or_state> - Count: <counter> Examples: · sbr-alarm: Alarm: ON - Condition: battery_removed - Value: 2 - Count: 12 · sbr-alarm: Alarm: ON - Condition: door - Value: opened - Count: 25 · sbr-alarm: Alarm: OFF - Condition: door - Value: opened - Count: 25
List of Alarms
The following is a list of the alarms provided by the Socket Based Router. · CPU Temp High · CPU Temp Low · Board Temp High

TDC-xxxx-xxx DRAFT

29

Proprietary and Confidential

Operation
· Board Temp Low · Battery1 Capacity Critical (Charge %) · Battery1 Capacity Warning (Charge %) · Battery2 Capacity Critical (Charge %) · Battery2 Capacity Warning (Charge %) · Battery1 Temp High · Battery1 Temp Low · Battery2 Temp High · Battery2 Temp Low · AC Power (Present/ Absent) · Door Status (Open/ Closed) · Fan Speed Low · Battery1 Removed (Inserted/ Removed) · Battery2 Removed (Inserted/ Removed) · LTE Connection (Lost/ Connected) · LTE Signal Low · Time Sync error

TDC-xxxx-xxx DRAFT

30

Proprietary and Confidential



Related FCC IDs:

Search Any Device: