Test Report 15.249 01

Snap One, LLC CORE5 2AJAC-CORE5 2AJACCORE5 core5

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 21 Pages, 1.44MB

Document DEVICE REPORTGetApplicationAttachment.html?id=5900029
Compliance Test Services
623 E. 100 S. Salt Lake City, UT 84102
Test Report
Certification

FCC ID IC ID Equipment Under Test Test Report Serial Number Date of Test(s) Report Issue Date

2AJAC-CORE5 7848A-CORE5 C4-CORE5 TR7030_01 January 6, 2022, and January 20, 2022 5 April 2022

Test Specification 47 CFR FCC Part 15, Subpart C ICES-003, Issue 7

Applicant Snap One LLC 1800 Continental Blvd., Suite 200-300 Charlotte NC 28273 U.S.A.

NVLAP LAB CODE 600293-0

Compliance Test Services

623 E. 100 S., Salt Lake City, UT 84102

Certification of Engineering Report
This report has been prepared by Compliance Test Services (CTS) to document compliance of the device described below with the requirement of Federal Communication Commissions (FCC) Part 15, Subpart C. This report may be reproduced in full. Partial reproduction of this report may only be made with the written consent of the laboratory. The results in this report apply only to the sample tested.

Applicant

Snap One LLC

Manufacturer Snap One LLC

Brand Name Control 4

Model Number C4-CORE5

FCC ID

2AJAC-CORE5

IC ID

7848A-CORE5

On this 5th day of April 2022, I individually and for Compliance Test Services certify that the statements made in this engineering report are true, complete, and correct to the best of my knowledge and are made in good faith.
Although NVLAP has accredited the Compliance Test Services testing facilities, this report must not be used to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the U.S. federal government.

Compliance Test Services

Written By: Clay Allred
Reviewed By: Joseph W. Jackson
TR7030_C4_C4-CORE5_FCC_15.249_01 PROPRIETARY

Page 2 of 21

Compliance Test Services
Revision 01

623 E. 100 S., Salt Lake City, UT 84102

Revision History Description
Original Report Release

Date 5 April 2022

TR7030_C4_C4-CORE5_FCC_15.249_01 PROPRIETARY

Page 3 of 21

Compliance Test Services

623 E. 100 S., Salt Lake City, UT 84102

Table of Contents
1 Client Information................................................................................................................................. 5 1.1 Applicant....................................................................................................................................... 5 1.2 Manufacturer................................................................................................................................. 5
2 Equipment Under Test (EUT)............................................................................................................... 6 2.1 Identification of EUT .................................................................................................................... 6 2.2 Description of EUT....................................................................................................................... 6 2.3 EUT and Support Equipment ........................................................................................................ 6 2.4 Interface Ports on EUT ................................................................................................................. 7 2.5 Operating Environment................................................................................................................. 8 2.6 Operating Modes........................................................................................................................... 8 2.7 EUT Exercise Software................................................................................................................. 8 2.8 Block Diagram of Test Configuration .......................................................................................... 8 2.9 Modification Incorporated/Special Accessories on EUT.............................................................. 8 2.10 Deviation, Opinions Additional Information or Interpretations from Test Standard.................... 8
3 Test Specification, Method and Procedures.......................................................................................... 9 3.1 Test Specification.......................................................................................................................... 9 3.2 Methods & Procedures.................................................................................................................. 9 3.3 FCC Part 15, Subpart C ................................................................................................................ 9 3.4 Results........................................................................................................................................... 9 3.5 Test Location .............................................................................................................................. 10
4 Test Equipment ................................................................................................................................... 10 4.1 Conducted Emissions at Mains Ports.......................................................................................... 10 4.2 Radiated Emissions ..................................................................................................................... 11 4.3 Equipment Calibration ................................................................................................................ 12 4.4 Measurement Uncertainty ........................................................................................................... 12
5 Test Results ......................................................................................................................................... 13 5.1 Conducted Emissions at Mains Ports Data ................................................................................. 13 5.2 Radiated Emissions: 908 MHz.................................................................................................... 15 5.3 Radiated Emissions: 916 MHz.................................................................................................... 15 5.4 Bandwidth ................................................................................................................................... 19 5.5 Fundamental Field Strength ........................................................................................................ 20

TR7030_C4_C4-CORE5_FCC_15.249_01 PROPRIETARY

Page 4 of 21

Compliance Test Services
1 Client Information
1.1 Applicant
Company
Contact Name Title
1.2 Manufacturer
Company
Contact Name Title

623 E. 100 S., Salt Lake City, UT 84102
Snap One LLC 1800 Continental Blvd., Suite 200-300 Charlotte NC 28273 U.S.A. Roger Midgley Principle Compliance Manager
Snap One LLC 1800 Continental Blvd., Suite 200-300 Charlotte NC 28273 U.S.A. Roger Midgley Principle Compliance Manager

TR7030_C4_C4-CORE5_FCC_15.249_01 PROPRIETARY

Page 5 of 21

Compliance Test Services

623 E. 100 S., Salt Lake City, UT 84102

2 Equipment Under Test (EUT)
2.1 Identification of EUT

Brand Name

Snap One LLC

Model Number

C4-CORE5

Hardware Version

Rev 4.0

Serial Number / MAC Address Rating/power supply RCB revision

ST21520017036F13, 000FFF0C3313
Input: AC 100V-240 VAC,50Hz/60Hz, Max 18W, Idle 9W, and PoE+
Rev 4.0

Schematic revision

Rev 4.0

Firmware/Software revision

3.3.0.618634

Dimensions (mm)

42

x 442 x 252

2.2 Description of EUT

The C4-CORE5 is a home entertainment controller, used to control home entertainment and home automation which features five independent audio outputs ­ three digital coaxial, three unbalanced stereo analog, one HDMI Out, wireless Zigbee and Z-wave communications, IR, serial, contacts and relays, and IP control. It also features a USB 3.0 connection for connection to external hard drives and a gigabit LAN port. It is powered via the AC mains and an internal 100-240Vac, 50/60Hz power supply.

The highest internal clocks or internal clock frequency on the EUT is the 2.4 GHz Zigbee wireless clock, and the internal system clock of 1.6 GHz.

This report covers the circuitry of the device subject to FCC Part 15, Subpart C. The circuitry of the device subject to FCC Part 15 Subpart B was found to be compliant and is covered under a separate Compliance Test Services test report.
2.3 EUT and Support Equipment

The EUT and support equipment used during the test are listed below.

Brand Name Model Number Serial Number

Description

BN: Snap One LLC MN: C4-CORE5 SN: ST21520017036F13

Home Entertainment Controller

TR7030_C4_C4-CORE5_FCC_15.249_01 PROPRIETARY

Name of Interface Ports / Interface Cables
EUT
Page 6 of 21

Compliance Test Services

623 E. 100 S., Salt Lake City, UT 84102

BN: Control4

MN: C4-EA3

Controller

Network/Cat 5e Cable

SN:

BN: Samsung

MN: UN43NU6900BXZA

4K TV

HDMI, Blue Jeans Cable

SN:09643CPMB13335K

BN: Unifi

MN: USW-Lite-8-PoE

Network switch + PoE Injector

Network/Cat 5e Cable

SN: 245A4C7BAD51

Notes: (1) EUT

(2) Interface port connected to EUT (See Section 2.4)

The support equipment listed above was not modified in order to achieve compliance with this standard.

2.4 Interface Ports on EUT

Name of No. of Ports Shielded Ferrite Core

Ports Fitted to EUT Cable

Installed

Cable Description/Length

Contact

1

No

No

Phoenix Contact connector w/12 unshielded conductors/1 meter

Relay

1

No

No

Phoenix Contact connector w/12 unshielded conductors/1 meter

Ethernet

1

No

No

Cat 5e/5 meters

HDMI Out

1

Yes

No

1 meter

USB (3.0)

1

Yes

No

USBA extension cable to USB flash drive/1 meter

Serial

2

No

No

Shielded cable with DB9 connectors/1 meter

IR Sensors

8

No

No

IR transmitters with unshielded cables with mono jacks/2 meters

Digital In

1

Yes

No

Cables with RCA connector/1 meter

Digital Out

3

Yes

No

Cables with RCA connector/1 meter

Analog

Audio In (Left and

2

Right)

Yes

No

Cables with RCA connector/1 meter

Analog

Audio Out (Left and

2

Right)

Yes

No

Cables with RCA connector/1 meter

802.15.4 Antenna

1

--

--

RP-SMA connectors direct to antenna

Z-Wave

1

Antenna

--

--

RP-SMA connectors direct to antenna

TR7030_C4_C4-CORE5_FCC_15.249_01

Page 7 of 21

PROPRIETARY

Compliance Test Services

623 E. 100 S., Salt Lake City, UT 84102

2.5 Operating Environment

Power Supply AC Mains Frequency Temperature Humidity Barometric Pressure

120V 60Hz 22 ­ 24 °C 20 ­ 27 % 1019 mBar

2.6 Operating Modes

The C4-CORE5 was set to constant transmit on low and high channels of the Z-wave radio. The Zigbee radio was also enabled to ensure emissions during simultaneous transmission were compliant. This configuration was determined to produce the worse-case emissions.
2.7 EUT Exercise Software

EUT firmware version 3.3.0.618634 was used to operate the transmitter using a constant transmit mode.
2.8 Block Diagram of Test Configuration

DUT

Ethernet

Cat 5E cable

Laptop

Diagram 1: Test Configuration Block Diagram
2.9 Modification Incorporated/Special Accessories on EUT
There were no modifications made to the EUT during testing to comply with the specification.
2.10 Deviation, Opinions Additional Information or Interpretations from Test Standard
There were no deviations, opinions, additional information or interpretations from the test specification.

TR7030_C4_C4-CORE5_FCC_15.249_01 PROPRIETARY

Page 8 of 21

Compliance Test Services

623 E. 100 S., Salt Lake City, UT 84102

3 Test Specification, Method and Procedures
3.1 Test Specification

Title Purpose of Test

47 CFR FCC Part 15, Subpart C 15.207, 15.215, and 15.249 Limits and methods of measurement of radio interference characteristics of radio frequency devices.
The tests were performed to demonstrate initial compliance

3.2 Methods & Procedures

3.2.1 47 CFR FCC Part 15 Section 15.207 See test standard for details. 3.2.2 47 CFR FCC Part 15 Section 15.215 See test standard for details. 3.2.3 47 CFR FCC Part 15 Section 15.249 See test standard for details.
3.3 FCC Part 15, Subpart C

3.3.1 Summary of Tests

FCC Section

ISED Section

15.207

RSS-Gen

15.215

RSS-Gen

Environmental Phenomena Conducted Disturbance at Mains Port
Bandwidth Requirement

Frequency Range (MHZ)

Result

0.15 to 30 Compliant

902 - 928 Compliant

15.249

RSS-Gen

Fundamental Field Strength 902 - 928 Compliant

15.249

RSS-Gen

Radiated Spurious Emissions

0.009 to 26000

Compliant

The testing was performed according to the procedures in ANSI C63.10-2013, KDB 558074 and 47 CFR Part 15. Where applicable, KDB 662911 was followed to sum required measurements.

3.4 Results

In the configuration tested, the EUT complied with the requirements of the specification.

TR7030_C4_C4-CORE5_FCC_15.249_01 PROPRIETARY

Page 9 of 21

Compliance Test Services

623 E. 100 S., Salt Lake City, UT 84102

3.5 Test Location
Testing was performed at the Compliance Test Services Draper location at 427 West 12800 South, Draper, UT 84020. Compliance Test Services is accredited by National Voluntary Laboratory Accreditation Program (NVLAP); NVLAP Code 600293-0 which is effective until December 31, 2022.

4 Test Equipment
4.1 Conducted Emissions at Mains Ports

Type of Equipment EMI Receiver
LISN
Cat6 ISN
ISN LISN AC Power Source Test Software

Manufacturer
AFJ AFJ
Teseq
Teseq Com-Power
Laplace Instruments
CTS

Model Number FFT3010 LS16C/10 ISN T8-
Cat6 ISN T800 LIN-120C
AC1000A
Revision 1

Asset Number CTS-2500 CTS-2512
CTS-2971
CTS-2974 CTS-2612
CTS-2857
CTS-3107

Date of Last Calibration CTS-6754 CTS-6749
CTS-2971
CTS-2974 CTS-2612
N/A
N/A

Due Date of Calibration 12/8/2021 12/6/2021
1/30/2022
6/4/2021 1/6/2022
N/A
N/A

Table 1: List of equipment used for Conducted Emissions Testing at Mains Port

Figure 1: Conducted Emissions Test

TR7030_C4_C4-CORE5_FCC_15.249_01 PROPRIETARY

Page 10 of 21

Compliance Test Services

623 E. 100 S., Salt Lake City, UT 84102

4.2 Radiated Emissions

Type of Equipment EMI Receiver Pre-Amplifier 9 kHz ­ 1 GHz Broadband
Antenna Broadband Antenna Double Ridge Horn Antenna Log Periodic 15 - 40 GHz Horn Antenna 1 ­ 18 GHz Amplifier Test Software

Manufacturer
Keysight Sonoma Instruments
Scwarzbeck

Model Number N9038A
310N

Asset Number CTS-2778
CTS-2889

VULB 9163 CTS-3062

Date of Last Calibration 6/21/2021
10/7/2021
8/28/2020

Scwarzbeck
Scwarzbeck Scwarzbeck Scwarzbeck

VULB 9163 CTS-3071

BBHA 9120D
STLP 9129

CTS-3065 CTS-3068

BBHA 9170 CTS-2487

5/19/2020
7/8/2021 11/16/2020 5/21/2020

Com-Power PAM 118A CTS-3833 10/7/2021

CTS

Revision 1 CTS-3108

N/A

Table 2: List of equipment used for Radiated Emissions

Due Date of Calibration 6/21/2022 10/7/2022
8/27/2022
5/19/2022
7/8/2022 11/16/2022 5/21/2022
10/7/2022 N/A

Figure 2: Radiated Emissions Test

TR7030_C4_C4-CORE5_FCC_15.249_01 PROPRIETARY

Page 11 of 21

Compliance Test Services

623 E. 100 S., Salt Lake City, UT 84102

4.3 Equipment Calibration

All applicable equipment is calibrated using either an independent calibration laboratory or Compliance Test Services personnel at intervals defined in ANSI C63.4:2014 following outlined calibration procedures. All measurement instrumentation is traceable to the National Institute of Standards and Technology (NIST). Supporting documentation relative to traceability is on file and is available for examination upon request.
4.4 Measurement Uncertainty

Test Conducted Emissions Asymmetric Mode Conducted Emissions Shielded CDN Conducted Emissions Radiated Emissions (30 MHz to 1 GHz) Radiated Emissions (1 GHz to 17 GHz)

Uncertainty (+ dB) 1.44 3.61 3.33 4.38 4.37

Confidence (%) 95 95 95 95 95

TR7030_C4_C4-CORE5_FCC_15.249_01 PROPRIETARY

Page 12 of 21

Compliance Test Services

623 E. 100 S., Salt Lake City, UT 84102

5 Test Results
5.1 Conducted Emissions at Mains Ports Data

Frequency (MHZ)

Detector

Receiver Measured
Level (dBµV)

Correction Factor (dB/m)

Corrected Receiver
Level (dBµV)

Limit Class B
Limit (dBµV)

Margin (dB)

13.56

Quasi-Peak (Note 2)

47.2

9.9

57.1

60

-2.9

10.61

Quasi-Peak (Note 2)

30.8

9.9

40.6

60

-19.4

0.150

Quasi-Peak (Note 2)

35.5

9.5

45

66

-21.0

15.23

Quasi-Peak (Note 2)

24.5

9.9

34.2

60

-25.7

0.261

Quasi-Peak (Note 2)

17.6

9.6

27.2

61.4

-34.2

Note 2: The reference detector used for the measurements was quasi-peak and average and the data was compared to the respective limits.

Sample Field Strength Calculation

Correction Factor = LISN Insertion Loss + Cable Insertion Loss + Transient Limiter Insertion Loss

Conducted Emissions Amplitude = Receiver Reading + Correction Factor

Result

The EUT complied with the specification limit by a margin of -2.9 dB.

Graph 1: Conducted Emissions Plot - Neutral
TR7030_C4_C4-CORE5_FCC_15.249_01 PROPRIETARY

Page 13 of 21

Compliance Test Services

623 E. 100 S., Salt Lake City, UT 84102

Frequency (MHZ)

Detector

Receiver Measured
Level (dBµV)

Correction Factor (dB/m)

Corrected Receiver
Level (dBµV)

Limit Class B
Limit (dBµV)

Margin (dB)

13.56

Quasi-Peak (Note 2)

47.1

9.9

57

60

-3.0

10.71

Quasi-Peak (Note 2)

30.1

9.9

40

60

-20.0

0.156

Quasi-Peak (Note 2)

30.9

9.5

40.5

65.7

-25.2

29.38

Quasi-Peak (Note 2)

17.4

10.2

27.6

60

-32.4

0.390

Quasi-Peak (Note 2)

14.6

9.6

24.2

58.1

-33.8

0.198

Average (Note 2)

17.1

9.5

26.6

53.7

-27.0

Note 2: The reference detector used for the measurements was quasi-peak and average and the data was compared to the respective limits.

Sample Field Strength Calculation

Correction Factor = LISN Insertion Loss + Cable Insertion Loss + Transient Limiter Insertion Loss

Conducted Emissions Amplitude = Receiver Reading + Correction Factor

Result

The EUT complied with the specification limit by a margin of -3.0 dB.

Graph 2: Conducted Emissions Plot ­ Line 1

TR7030_C4_C4-CORE5_FCC_15.249_01 PROPRIETARY

Page 14 of 21

Compliance Test Services

623 E. 100 S., Salt Lake City, UT 84102

5.2 Radiated Emissions: 908 MHz

Freq. (MHZ)

Level (dBµV/m)

Limit (dBµV/m)

Margin (dB)

Azimuth (°)

Height (m)

Pol.

Cor. (dB)

Det.

11638

55.111

74

-18.889

97

3.233 Hztl 13.942

Pk

15004

58.559

74

-15.441

107

3.097 Hztl 16.089

Pk

16805

59.336

74

-14.664

84

3.444 Hztl 17.628

Pk

11638

42.01

54

-11.99

97

3.233 Hztl 13.942 Avg

15004

45.275

54

-8.725

107

3.097 Hztl 16.089 Avg

16805

45.633

54

-8.367

84

3.444 Hztl 17.628 Avg

Sample Field Strength Calculation Level = Receiver Reading + Correction Factor Correction Factor = Antenna Factor + Cable Factor - Amplifier Margin = Level - Limit

Result The EUT complied with the specification limit by a margin of -8.367 dB. Emissions below 1 GHz were investigated but worst case was with 916 MHz transmitting

5.3 Radiated Emissions: 916 MHz

Freq. (MHz)

Level (dBµV/m)

Limit (dBµV/m)

Margin (dB)

Azimuth (°)

Height (m)

Pol.

Cor. (dB)

Det.

30.485

25.896

30

-4.104

298

2.352

Vrt -11.794

QP

40.864

25.187

30

-4.813

102

3.847

Vrt -11.183

QP

54.347

25.423

30

-4.577

102

3.42

Vrt -12.11

QP

178.41

24.79

33.5

-8.71

204

1.311

Vrt -15.747

QP

11068

55.212

74

-18.788

95

3.773 Hztl 14.103

Pk

14451

58.125

74

-15.875

354

1.862 Hztl 15.998

Pk

16904

60.06

74

-13.94

237

3.08

Hztl 18.354

Pk

11068

41.638

54

-12.362

95

3.773 Hztl 14.103 Avg

14451

45.144

54

-8.856

354

1.862 Hztl 15.998 Avg

16904

46.322

54

-7.678

237

Sample Field Strength Calculation Level = Receiver Reading + Correction Factor Correction Factor = Antenna Factor + Cable Factor - Amplifier Margin = Level - Limit

3.08

Hztl 18.354 Avg

TR7030_C4_C4-CORE5_FCC_15.249_01 PROPRIETARY

Page 15 of 21

Compliance Test Services

623 E. 100 S., Salt Lake City, UT 84102

Result The EUT complied with the specification limit by a margin of -4.104 dB.

30-1000MHz worst case with 916 MHz transmitting

TR7030_C4_C4-CORE5_FCC_15.249_01 PROPRIETARY

Page 16 of 21

Compliance Test Services

623 E. 100 S., Salt Lake City, UT 84102

1-17 GHz 908 MHz

1-17 GHz 916 MHz

TR7030_C4_C4-CORE5_FCC_15.249_01 PROPRIETARY

Page 17 of 21

Compliance Test Services

623 E. 100 S., Salt Lake City, UT 84102

1-17 GHz 908 MHz and 2440 MHz for reference only

1-17 Hz 916 MHz and 2440 MHz for reference only

TR7030_C4_C4-CORE5_FCC_15.249_01 PROPRIETARY

Page 18 of 21

Compliance Test Services
5.4 Bandwidth

623 E. 100 S., Salt Lake City, UT 84102

908 MHz OBW

916 MHz OBW
TR7030_C4_C4-CORE5_FCC_15.249_01 PROPRIETARY

Page 19 of 21

Compliance Test Services

623 E. 100 S., Salt Lake City, UT 84102

5.5 Fundamental Field Strength

Freq. (MHZ)
908.46

Level (dBµV/m)

Limit Margin (dBµV/m) (dB)

Azimuth (°)

Height (m)

Pol.

Cor. (dB)

Det.

94.06

114

-19.94

114

1.08 Hor¹ 32.185 Pk

908.46

90.79

94

-3.2

114

1.08 Hor¹ 32.185 Avg

915.96

95.88

114

-18.12

277

1.08 Hor¹ 32.221 Pk

915.96

93.41

¹: Worst case polarity

94

-0.59

277

1.08 Hor¹ 32.221 Avg

TR7030_C4_C4-CORE5_FCC_15.249_01 PROPRIETARY

Page 20 of 21

Compliance Test Services

623 E. 100 S., Salt Lake City, UT 84102

-- End of Test Report --