SZ22100161W16 Tengfei NX729J WiFi5G DFS NII

Morlab

Test Report DFS

Shenzhen Tengfei Technology Management Ltd. NX729J 2A9QD-NX729J 2A9QDNX729J nx729j

download (pdf)

NX729J 5 G Mobile Phone by Shenzhen Tengfei Management

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 23 Pages, 594.51KB

Document DEVICE REPORTNX729J-Test-Report-Shenzhen-Tengfei-Management-2a9qd-nx729j-ex-6-30
REPORT No.SZ22100161W16
TEST REPORT

APPLICANT PRODUCT NAME

:

Shenzhen Tengfei Technology Management Ltd.

: 5G Mobile Phone

MODEL NAME

: NX729J

BRAND NAME

: REDMAGIC

FCC ID

: 2A9QD-NX729J

STANDARD(S)

: 47 CFR Part 15 Subpart E

RECEIPT DATE

: 2022-11-01

TEST DATE

: 2022-11-07 to 2022-11-30

ISSUE DATE

: 2022-12-16

Edited by:

Zeng Xiaoying (Rapporteur)

Approved by: Shen Junsheng (Supervisor)

NOTE: This document is issued by Shenzhen Morlab Communications Technology Co., Ltd., the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 1 of 23

REPORT No.SZ22100161W16
DIRECTORY
1. Technical Information 3 1.1. Applicant and Manufacturer Information  3 1.2. Equipment Under Test (EUT) Description  3 1.3. Companion Equipment(Master) Description  5 1.4. The Channel Number and Frequency  6 1.5. Test Standards and Results  7 1.6. Environmental Conditions 7 2. 47 CFR Part 15E Requirements 8 2.1. Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS)  8 Annex A Test Uncertainty 21 Annex B Testing Laboratory Information  22

Version 1.0

Change History Date 2022-12-16

Reason for change First edition

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 2 of 23

1. Technical Information

REPORT No.SZ22100161W16

Note: Provide by applicant.
1.1. Applicant and Manufacturer Information

Applicant: Applicant Address: Manufacturer: Manufacturer Address:

Shenzhen Tengfei Technology Management Ltd. Room 3101, Building D1, Chuangzhi Yuncheng, Liuxian Avenue, Xili Street, Nanshan, Shenzhen, China Shenzhen Tengfei Technology Management Ltd. Room 3101, Building D1, Chuangzhi Yuncheng, Liuxian Avenue, Xili Street, Nanshan, Shenzhen, China

1.2. Equipment Under Test (EUT) Description

Product Name: Serial No.: Hardware Version: Software Version: Modulation Type:
Modulation Mode:
Operating Frequency Range:
Channel Number: Antenna Type: Antenna Gain: Directional Gain:

5G Mobile Phone 1# NX729J_V1AMB NX729J_UNCommon_V3.03 OFDM 802.11a, 802.11n (HT20), 802.11n (HT40) 802.11ac (VHT20), 802.11ac (VHT40), 802.11ac (VHT80) 802.11ax (HEW20), 802.11ax (HEW40), 802.11ax (HEW80) 5180MHz­5240MHz; 5260MHz­5320MHz; 5500MHz­5720MHz; 5745MHz-5825MHz Refer to 1.4 PIFA Antenna ANT 0: -0.2dBi; ANT 1: -0.8dBi 2.51dBiNote 2

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 3 of 23

REPORT No.SZ22100161W16

Battery

Brand Name:

ATL

Model No.:

Li3928T89P8h603285

Accessory Information:

Serial No.: Capacity:

N/A 2860mAh

Rated Voltage: 7.78V

Charge Limit:

8.9V

Manufacturer:

Dongguan Amperex Technology Limited

AC Adapter

Brand Name:

N/A

Model No.:

STC-A59152050AC-Z

Serial No.:

N/A

Accessory Information:

Rated Output: Rated Input:

5V 3A, 9V 3A, 15V 3A, 20V 3.25A, PPS: 5.0V-11.0V 5.0A, 5.0V-20.0V 3.25A
100-240V 50/60Hz, 1.5A

Manufacturer:

ShenZhen KunXing Technology Co.,Ltd.

USB Cable

Model No.:

N52111200016D

Note 1: The EUT supports a MIMO function. Physically, the EUT provides two completed transmitters and two receivers for 802.11n, 802.11ac and 802.11ax modulation mode.

Modulation Mode:

TX Function

802.11n

2TX

802.11ac

2TX

802.11ax

2TX

Note 2: According to KDB 662911 D01, the directional gain = GANT + 10log(NANT) dBi, where GANT is the maximum antenna gain in dBi, NANT is the number of outputs. Note 3: For conducted test item of each modulation mode, we recorded the test result of two antennas separately, for other conducted test items both of the two antennas were tested

separately, we only recorded the worst test result (ANT0) in this report.

Note 4: For a more detailed description, please refer to Specification or User's Manual supplied by the applicant and/or manufacturer.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 4 of 23

REPORT No.SZ22100161W16
1.3. Companion Equipment(Master) Description

Product Name: Manufacturer: FCC ID: Serial No: Antenna Gain:

Router Cisco LDK102091 FGL1848X9S5 2.1dBi

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 5 of 23

REPORT No.SZ22100161W16
1.4. The Channel Number and Frequency

(U-NII-1) 5180MHz-5240MHz

Bandwidth

Channel

Frequency (MHz)

20MHz

36 44

40MHz

38

5180 5220 5190

80MHz

42

(U-NII-2A) 5260MHz-5320MHz

Bandwidth

Channel

5210 Frequency (MHz)

20MHz

52 60

5260 5300

40MHz

54

80MHz

58

(U-NII-2C) 5500MHz-5720MHz

Bandwidth

Channel

100

108

20MHz

116 124

132

140

5270 5290
Frequency (MHz) 5500 5540 5580 5620 5660 5700

102

40MHz

118

134

5510 5590 5670

80MHz

106 138

5530 5690

(U-NII-3) 5745MHz-5825MHz

Bandwidth

Channel

149

20MHz

157

165

Frequency (MHz) 5745 5785 5825

40MHz

151

5775

80MHz

155

5775

Note 1: The black bold channels were selected for test.

Channel 40 48 46
Channel 56 64 62
Channel 105 112 120 128 136 144 110 126 142 122
Channel 153 161
159

Frequency (MHz) 5200 5240 5230
Frequency (MHz) 5280 5320 5310
Frequency (MHz) 5520 5560 5600 5640 5680 5720 5550 5630 5710 5610
Frequency (MHz) 5765 5805
5795

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 6 of 23

1.5. Test Standards and Results

REPORT No.SZ22100161W16

The objective of the report is to perform testing according to 47 CFR Part 15 Subpart E (U-NII band)

for the EUT FCC ID Certification:

No. Identity

Document Title

1 47 CFR Part 15 (5-1-14 Edition)

Radio Frequency Devices

Test detailed items/section required by FCC rules and results are as below:

No. Section Description

Test Date

Test Engineer

Result

Method Determination
/Remark

1

15.407(h) TPC and DFS Nov. 30, 2022

Zhong Yanshan

PASS No deviation

Note 1: The DFS section for U-NII band is applicable to this report; the other test items are

documented in a separate report.

Note 2: These RF tests were performed according to the method of measurements prescribed

in KDB 905462 D02 UNII DFS Compliance Procedures New Rules v02.

Note 3: Additions to, deviation, or exclusions from the method shall be judged in the "method

determination" column of add, deviate or exclude from the specific method shall be explained in

the "Remark" of the above table.

Note 4: When the test result is a critical value, we will use the measurement uncertainty give the

judgment result based on the 95% confidence intervals.

1.6. Environmental Conditions

During the measurement, the environmental conditions were within the listed ranges:

Temperature (°C): Relative Humidity (%): Atmospheric Pressure (kPa):

15-35 30-60 86-106

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 7 of 23

REPORT No.SZ22100161W16
2. 47 CFR Part 15E Requirements

2.1. Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS)

2.1.1. Requirement

According to FCC section 15.407(h), (1) Transmit power control (TPC). U-NII devices operating in

the 5.25-5.35 GHz band and the 5.47-5.725 GHz band shall employ a TPC mechanism. The U-NII

device is required to have the capability to operate at least 6 dB below the mean EIRP value of 30

dBm. A TPC mechanism is not required for systems with an e.i.r.p. of less than 500 mW. (2) Radar

Detection Function of Dynamic Frequency Selection (DFS). U-NII devices operating with any part

of its 26 dB emission bandwidth in the 5.25-5.35 GHz and 5.47-5.725 GHz bands shall employ a

DFS radar detection mechanism to detect the presence of radar systems and to avoid co-channel

operation with radar systems. Operators shall only use equipment with a DFS mechanism that is

turned on when operating in these bands. The device must sense for radar signals at 100 percent

of its emission bandwidth. The minimum DFS detection threshold for devices with a maximum

e.i.r.p. of 200 mW to 1 W is -64 dBm. For devices that operate with less than 200 mW e.i.r.p. and a

power spectral density of less than 10 dBm in a 1 MHz band, the minimum detection threshold is

-62 dBm. The detection threshold is the received power averaged over 1 microsecond referenced

to a 0 dBi antenna. For the initial channel setting, the manufacturers shall be permitted to provide

for either random channel selection or manual channel selection.

A U-NII network will employ a DFS function to detect signals from radar systems and to avoid

co-channel operation with these systems. This applies to the 5250-5350 MHz and/or 5470-5725

MHz bands.1

Within the context of the operation of the DFS function, a U-NII device will operate in either Master

Mode or Client Mode. U-NII devices operating in Client Mode can only operate in a network

controlled by a U-NII device operating in Master Mode.2

Tables 1 and 2 shown below summarize the information contained in sections 5.1.1 and 5.1.2.

Table 1: Applicability of DFS Requirements Prior to Use of a Channel

Operational Mode

Requirement

Master

Client Without Radar Client With Radar

Detection

Detection

Non-Occupancy Period

Yes

Not required

Yes

DFS Detection Threshold

Yes

Not required

Yes

Channel Availability Check Time

Yes

Not required

Not required

U-NII Detection Bandwidth

Yes

Not required

Yes

Table 2: Applicability of DFS requirements during normal operation

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 8 of 23

REPORT No.SZ22100161W16

Requirement
DFS Detection Threshold Channel Closing Transmission Time
Channel Move Time U-NII Detection Bandwidth

Master Yes Yes Yes Yes

Operational Mode Client Without Radar Detection
Not required Yes Yes
Not required

Additional requirements for devices with multiple bandwidth modes

Master Device or Client with Radar Detection

Client Without Radar Detection

U-NII Detection Bandwidth and Statistical Performance Check

All BW modes must be tested

Not required

Channel Move Time and Channel Test using widest BW mode Test using the widest BW

Closing Transmission Time

available

mode available for the link

All other tests

Any single BW mode

Not required

Note: Frequencies selected for statistical performance check (Section 7.8.4) should include

several frequencies within the radar detection bandwidth and frequencies near the edge of the

radar detection bandwidth. For 802.11 devices it is suggested to select frequencies in each of

the bonded 20 MHz channels and the channel center frequency.

The operational behavior and individual DFS requirements that are associated with these modes

are as follows:

Master Devices

a) The Master Device will use DFS in order to detect Radar Waveforms with received signal

strength above the DFS Detection Threshold in the 5250 - 5350 MHz and 5470 - 5725 MHz bands.

DFS is not required in the 5150 - 5250 MHz or 5725 - 5825 MHz bands.

b) Before initiating a network on a Channel, the Master Device will perform a Channel Availability Check for specified time duration (Channel Availability Check Time) to ensure that there is no radar system operating on the Channel, using DFS described under subsection a) above.

c) The Master Device initiates a U-NII network by transmitting control signals that will enable other U-NII devices to Associate with the Master Device.

d) During normal operation, the Master Device will monitor the Channel (In-Service Monitoring) to ensure that there is no radar system operating on the Channel, using DFS described under a).

e) If the Master Device has detected a Radar Waveform during In-Service Monitoring as described under d), the Operating Channel of the U-NII network is no longer an Available Channel. The Master Device will instruct all associated Client Device(s) to stop transmitting on this Channel within the Channel Move Time. The transmissions during the Channel Move Time will be limited to the Channel Closing Transmission Time.

f) Once the Master Device has detected a Radar Waveform it will not utilize the Channel for the

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 9 of 23

REPORT No.SZ22100161W16

duration of the Non-Occupancy Period. 3.

g) If the Master Device delegates the In-Service Monitoring to a Client Device, then the combination will be tested to the requirements described under d) through f) above.

Client Devices a) A Client Device will not transmit before having received appropriate control signals from a Master Device.

b) A Client Device will stop all its transmissions whenever instructed by a Master Device to which it is associated and will meet the Channel Move Time and Channel Closing Transmission Time requirements. The Client Device will not resume any transmissions until it has again received control signals from a Master Device.

c) If a Client Device is performing In-Service Monitoring and detects a Radar Waveform above the DFS Detection Threshold, it will inform the Master Device. This is equivalent to the Master Device

detecting the Radar Waveform and d) through f) of section 5.1.1 apply.

d) Irrespective of Client Device or Master Device detection the Channel Move Time and Channel Closing Transmission Time requirements remain the same.

e) The client test frequency must be monitored to ensure no transmission of any type has occurred

for 30 minutes. Note: If the client moves with the master, the device is considered compliant if

nothing appears in the client non-occupancy period test. For devices that shut down (rather than

moving channels), no beacons should appear.

DFS Detection Thresholds

Table 3 below provides the DFS Detection Thresholds for Master Devices as well as Client

Devices incorporating In-Service Monitoring.

Table 3: DFS Detection Thresholds for Master Devices and Client Devices with Radar

Detection

Maximum Transmit Power

Value (See Notes 1, 2, and 3)

EIRP  200 mill watt

-64 dBm

EIRP < 200 mill watt and power spectral density < 10 dBm/MHz

-62 dBm

EIRP < 200 mill watt that do not meet the power spectral density requirement

-64 dBm

Note 1: This is the level at the input of the receiver assuming a 0 dBi receive antenna. Note 2: Throughout these test procedures an additional 1 dB has been added to the amplitude of

the test transmission waveforms to account for variations in measurement equipment. This will ensure that the test signal is at or above the detection threshold level to trigger a DFS response. Note3: EIRP is based on the highest antenna gain. For MIMO devices refer to KDB Publication

662911 D01.

Response Requirements

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 10 of 23

REPORT No.SZ22100161W16

Table 4 provides the response requirements for Master and Client Devices incorporating DFS.

Table 4: DFS Response Requirement Values

Parameter

Value

Non-occupancy period

Minimum 30 minutes

Channel Availability Check Time

60 seconds

Channel Move Time

10 seconds See Note 1.

Channel Closing Transmission Time

200 milliseconds + an aggregate of 60 milliseconds over remaining 10 second period. See Notes 1 and 2.

U-NII Detection Bandwidth

Minimum 100% of the U-NII 99% transmission power bandwidth. See Note 3.

Note 1: Channel Move Time and the Channel Closing Transmission Time should be performed

with Radar Type 0. The measurement timing begins at the end of the Radar Type 0 burst.

Note 2: The Channel Closing Transmission Time is comprised of 200 milliseconds starting at

the beginning of the Channel Move Time plus any additional intermittent control signals required

to facilitate a Channel move (an aggregate of 60 milliseconds) during the remainder of the 10

second period. The aggregate duration of control signals will not count quiet periods in between

transmissions.

Note 3: During the U-NII Detection Bandwidth detection test, radar type 0 should be used. For

each frequency step the minimum percentage of detection is 90 percent. Measurements are

performed with no data traffic.

2.1.2. Test Description

According to Section 7.2 of KDB 905462 D02 V01R01 1. Setup for Master with injection at the Master

(Example Conducted Setup where UUT is a Master and Radar Test Waveforms are injected into the Master) 2. Setup for Client with injection at the Master

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 11 of 23

REPORT No.SZ22100161W16
(Example Conducted Setup where UUT is a Client and Radar Test Waveforms are injected into the Master) 3. Setup for Client with injection at the Client
(Example Conducted Setup where UUT is a Client and Radar Test Waveforms are injected into the Client)

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 12 of 23

REPORT No.SZ22100161W16

2.1.3. Test Result

a.Channel loading between Master and Client

Test Mode

Channel

11AC20SISO

5320 5500

11AC80SISO

5290 5530

Test Plot

11AC20SISO_5320

Result 48.06 43.51 36.08 35.81

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 13 of 23

REPORT No.SZ22100161W16
11AC20SISO_5500
11AC80SISO_5290

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 14 of 23

REPORT No.SZ22100161W16
11AC80SISO_5530

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 15 of 23

REPORT No.SZ22100161W16

b.DFS Detection Threshold:

Test Mode

Channel

11AC20SISO

5320 5500

11AC80SISO

5290 5530

Radar Type Reference Reference Reference Reference

Result -62.51 -61.53 -62.51 -62.36

Limit[dbm] -59.20 -59.20 -59.20 -59.20

Verdict PASS PASS PASS PASS

11AC20SISO_5320_Reference

11AC20SISO_5500_Reference

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 16 of 23

REPORT No.SZ22100161W16
11AC80SISO_5290_Reference
11AC80SISO_5530_Reference

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 17 of 23

REPORT No.SZ22100161W16

c.Channel Closing Transmission Time and Channel Move Time:

Test Mode Channel CCT[ms] Limit[ms]

CMT[ms]

11AC20SISO

5320 5500

66.42 113.4

260 260

785.6 858.7

11AC80SISO

5290 5530

64.8 110.16

260 260

98.2 169.7

Limit[ms] 10000 10000 10000 10000

Verdict PASS PASS PASS PASS

11AC20SISO_5320

11AC20SISO_5500

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 18 of 23

REPORT No.SZ22100161W16
11AC80SISO_5290
11AC80SISO_5530

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 19 of 23

d.Non-Occupancy Period

Test Mode Channel

11AC20SISO

5320 5500

REPORT No.SZ22100161W16

Result see test graph see test graph
11AC20SISO_5320

Limit[s] 1800 1800

Verdict PASS PASS

11AC20SISO_5500

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 20 of 23

Annex A Test Uncertainty

REPORT No.SZ22100161W16

Where relevant, the following measurement uncertainty levels have been estimated for test

performed on the EUT as specified in CISPR 16-1-2:

Test Items

Uncertainty

Bandwidth

±5%

Conducted Emission

±2.44dB

This uncertainty represent an expanded uncertainty expressed at approximately the 95%

confidence level using a coverage factor of k=2.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 21 of 23

REPORT No.SZ22100161W16
Annex B Testing Laboratory Information

1. Identification of the Responsible Testing Laboratory

Laboratory Name:
Laboratory Address:
Telephone: Facsimile:

Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China +86 755 36698555 +86 755 36698525

2. Identification of the Responsible Testing Location

Name: Address:

Shenzhen Morlab Communications Technology Co., Ltd. FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

3. Facilities and Accreditations

All measurement facilities used to collect the measurement data are located at FL.3, Building A, FeiYang Science Park, Block 67, BaoAn District, Shenzhen, 518101 P. R. China. The test site is constructed in conformance with the requirements of ANSI C63.10-2013 and CISPR Publication 22; the FCC designation number is CN1192, the test firm registration number is 226174.

MORLAB

Shenzhen Morlab Communications Technology Co., Ltd. FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.cn

Fax: 86-755-36698525 E-mail: [email protected]
Page 22 of 23

REPORT No.SZ22100161W16

4. Test Equipments Utilized

4.1 Conducted Test Equipments

Equipment Name Serial No.

Power Splitter

N/A

Attenuator 1

N/A

Attenuator 2

N/A

EXA Signal Analzyer

MY53470836

MXG Vector Signal Generator

MY53050961

RF Cable (30MHz-26GHz)

CB01

Coaxial Cable

CB02

SMA Connector

CN01

Type N/A N/A N/A N9010A
N5182B
RF01 RF02 RF03

Manufacturer N/A N/A N/A

Cal. Date N/A N/A N/A

Due Date N/A N/A N/A

Agilent

2022.03.01 2023.02.28

Angilent

2022.03.01 2023.02.28

Morlab

N/A

N/A

Morlab

N/A

N/A

HUBERSUHNER

N/A

N/A

END OF REPORT