Part 15B Report
andy.yan
Test Report
Warner Bros. Home Entertainment Inc. 3000061481 ZEUS XBOX ONE PORTAL 2ADL5-3000061481 2ADL53000061481 3000061481
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 33 Pages, 323.80KB
Document DEVICE REPORTGetApplicationAttachment.html?id=2600556WARNER BROS. HOME ENTERTAINMENT INC. Application For Certification FCC ID: 2ADL5-3000061481 ZEUS XBOX ONE PORTAL Model: 3000061481 Class B Personal Computer Peripherals Report No.: SZHH00943010-002 Prepared and Checked by: Sign on file Jimmy Wen Senior Engineer Approved by: Digitally signed by Andy Yan Location: Intertek Testing Services Andy Yan Senior Project Engineer Date: April 24, 2015 · The test results reported in this test report shall refer only to the sample actually tested and shall not refer or be deemed to refer to bulk from which such a sample may be said to have been obtained. · This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results referenced from this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. · For Terms And Conditions of the services, it can be provided upon request. · The evaluation data of the report will be kept for 3 years from the date of issuance. TRF No.: FCC 15C_PC_b Intertek Testing Services Shenzhen Ltd. Kejiyuan Branch 6F, D Block, Huahan Building, Langshan Road, Nanshan District, Shenzhen, P. R. China Tel: (86 755) 8601 6288 Fax: (86 755) 8601 6751 Website: www.china.intertek-etlsemko.com INTERTEK TESTING SERVICES LIST OF EXHIBITS INTRODUCTION EXHIBIT 1: EXHIBIT 2: EXHIBIT 3: EXHIBIT 4: EXHIBIT 5: EXHIBIT 6: EXHIBIT 7: EXHIBIT 8: EXHIBIT 9: EXHIBIT 10: General Description System Test Configuration Emission Results Equipment Photographs Product Labeling Technical Specifications Instruction Manual Miscellaneous Information Confidentiality Request Test Equipment List TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 i INTERTEK TESTING SERVICES MEASUREMENT / TECHNICAL REPORT WARNER BROS. HOME ENTERTAINMENT INC. MODEL: 3000061481 FCC ID: 2ADL5-3000061481 This report concerns (check one:) Original Grant X Class II Change Equipment Type: JBP-Part 15 Class B Computing Device/Peripherals Deferred grant requested per 47 CFR 0.457(d)(1)(ii)? Yes No X If yes, defer until: date Company Name agrees to notify the Commission by: date of the intended date of announcement of the product so that the grant can be issued on that date. Transition Rules Request per 15.37? Yes No X If no, assumed Part 15, Subpart B for unintentional radiator - the new 47 CFR [10-01-13 Edition] provision. Report prepared by: Jimmy Wen Intertek Test Services Shenzhen Ltd. Kejiyuan Branch 6F, D Block, Huahan Building, Langshan Road Nanshan District, Shenzhen, P. R. China Phone: (86 755) 8614 0713 Fax: (86 755) 8614 6751 TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 ii INTERTEK TESTING SERVICES Table of Contents 1.0 General Description......................................................................................... 2 1.1 Product Description................................................................................... 2 1.2 Related Submittal(s) Grants ...................................................................... 2 1.3 Test Methodology...................................................................................... 2 1.4 Test Facility ............................................................................................... 2 2.0 System Test Configuration ............................................................................. 4 2.1 Justification ............................................................................................... 4 2.2 EUT Exercising Software .......................................................................... 4 2.3 Special Accessories .................................................................................. 4 2.4 Equipment Modification ............................................................................. 4 2.5 Measurement Uncertainty ......................................................................... 5 2.6 Support Equipment List and Description ................................................... 5 3.0 Emission Results.............................................................................................. 7 3.1 Field Strength Calculation ............................................................................. 8 3.2 Radiated Emission Configuration Photograph ............................................... 9 3.3 Radiated Emission Data ............................................................................... 9 3.4 Conducted Emission Configuration Photograph .......................................... 11 3.5 Conducted Emission Data..............................................................................11 4.0 Equipment Photographs................................................................................... 15 5.0 Product Labelling .............................................................................................. 17 6.0 Technical Specifications................................................................................... 19 7.0 Instruction Manual ............................................................................................ 21 8.0 Miscellaneous Information ............................................................................... 23 8.1 Emissions Test Procedures ....................................................................... 23 9.0 Confidentiality Request................................ .................................................26 10.0 Test Equipment List ..................................................................................... .. 28 TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 iii INTERTEK TESTING SERVICES Exhibit type Test Report Test Setup Photo Test Setup Photo External Photo Internal Photo Block Diagram ID Label/Location User Manual Cover Letter Cover Letter List of attached file File Description Test Report Radiated Emission Conducted Emission External Photo Internal Photo Block Diagram Label Artwork and Location User Manual Confidentiality Letter Letter of Agency Filename report.pdf radiated photos.pdf conducted photos.pdf external photos.pdf internal photos.pdf block.pdf label.pdf manual.pdf request.pdf agency.pdf TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 iv INTERTEK TESTING SERVICES EXHIBIT 1 GENERAL DESCRIPTION TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 1 INTERTEK TESTING SERVICES 1.0 General Description 1.1 Product Description The equipment under test (EUT) is a transceiver for a ZEUS XBOX ONE PORTAL model: 3000061481 operating at 13.56 MHz. The EUT is powered by DC 5.0V with power by USB host Unit. Data can be transferred through USB port between the personal computers and the EUT. For more detailed features description, please refer to the user's manual. 1.2 Related Submittal(s) Grants This is an application for certification of a computer peripherals. 1.3 Test Methodology Both AC mains line-conducted and radiated emission measurements were performed according to the procedures in ANSI C63.4 (2009). Radiated emission measurement was performed in Semi-anechoic chamber and conducted emission measurement was performed in shield room. For radiated emission measurement, preliminary scans were performed in the semianechoic chamber only to determine the worst case modes. All radiated tests were performed at an antenna to EUT distance of 3 meters, unless stated otherwise in the "Justification Section" of this Application. 1.4 Test Facility The Semi-anechoic chamber and shielding room used to collect the radiated data and conducted data are Intertek Test Services Shenzhen Ltd. Kejiyuan Branch and located at 6F, D Block, Huahan Building, Langshan Road, Nanshan District, Shenzhen, P. R. China. This test facility and site measurement data have been fully placed on file with the FCC (Registration Number: 242492). TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 2 INTERTEK TESTING SERVICES EXHIBIT 2 SYSTEM TEST CONFIGURATION TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 3 INTERTEK TESTING SERVICES 2.0 System Test Configuration 2.1 Justification The system was configured for Test in a typical fashion (as a customer would normally use it), and in the confines as outlined in ANSI C63.4 (2009). The EUT was powered by DC 5.0V USB Port through the notebook (the notebook was powered through AC 120V/60Hz) during test. For maximizing emissions, the EUT was rotated through 360°, the antenna height was varied from 1 meter to 4 meters above the ground plane, and the antenna polarization was changed. The step by step procedure for maximizing emissions led to the data reported in Exhibit 3.0. The rear of unit shall be flushed with the rear of the table. The equipment under test (EUT) was configured for Test in a typical fashion (as a customer would normally use it). The EUT was placed on turntable, which enabled the engineer to maximize emissions through its placement in the three orthogonal axes. The frequency range from 30MHz to 1GHz (EUT highest frequency is less than 1GHz, so according to 15.33, the test range is update to 1GHz) was searched for spurious emissions from the device. Only those emissions reported were detected. All other emissions were at least 20 dB below the applicable limits. 2.2 EUT Exercising Software The EUT exercise program (provided by client) used during radiated and conducted Test was designed to exercise the various system components in a manner similar to a typical use. The worst case configuration is used in all specified Test. 2.3 Special Accessories There are no special accessories necessary for compliance of this product. 2.4 Equipment Modification Any modifications installed previous to Test by WARNER BROS. HOME ENTERTAINMENT INC. Will be incorporated in each production model sold / leased in the United States. TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 4 INTERTEK TESTING SERVICES No modifications were installed by Intertek Test Services Shenzhen Ltd. Kejiyuan Branch. 2.5 Measurement Uncertainty When determining the test conclusion, the Measurement Uncertainty of test has been considered. 2.6 Support Equipment List and Description This product was tested in the following configuration: Refer List: Description Laptop Hard Disk 1394 Cable USB Cable Manufacturer Lenovo Smart.drive Smart.drive Smart.drive Model No. T420 HD-003 Unshielded, Length 180cm Unshielded, Length 120cm TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 5 INTERTEK TESTING SERVICES EXHIBIT 3 EMISSION RESULTS TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 6 INTERTEK TESTING SERVICES 3.0 Emission Results Data is included worst case configuration (the configuration which resulted in the highest emission levels). A sample calculation, configuration photographs and data tables of the emissions are included. TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 7 INTERTEK TESTING SERVICES 3.1 Field Strength Calculation The field strength is calculated by adding the reading on the Spectrum Analyzer to the factors associated with preamplifiers (if any), antennas, cables, pulse desensitization and average factors (when specified limit is in average and measurements are made with peak detectors). A sample calculation is included below. FS = RA + AF + CF - AG + PD + AV where FS = Field Strength in dBµV/m RA = Receiver Amplitude (including preamplifier) in dBµV CF = Cable Attenuation Factor in dB AF = Antenna Factor in dB AG = Amplifier Gain in dB PD = Pulse Desensitization in dB AV = Average Factor in -dB In the radiated emission table which follows, the reading shown on the data table may reflect the preamplifier gain. An example of the calculations, where the reading does not reflect the preamplifier gain, follows: FS = RA + AF + CF - AG + PD + AV Example Assume a receiver reading of 62.0dBµV is obtained. The antenna factor of 7.4dB and cable factor of 1.6dB is added. The amplifier gain of 29dB is subtracted. The pulse desensitization factor of the spectrum analyzer was 0dB, and the resultant average factor was -10dB. The net field strength for comparison to the appropriate emission limit is 32dBµV/m. This value in dBµV/m was converted to its corresponding level in µV/m. RA = 62.0dBµV AF = 7.4dB CF = 1.6dB AG = 29.0dB PD = 0dB AV = -10dB FS = 62 + 7.4 + 1.6 - 29 + 0 + (-10) = 32dBµV/m Level in µV/m = Common Antilogarithm [(32dBµV/m)/20] = 39.8µV/m TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 8 INTERTEK TESTING SERVICES 3.2 Radiated Emission Configuration Photograph Worst Case Radiated Emission At 40.67MHz (Data transfer Mode) For electronic filing, the worst case radiated emission configuration photograph is saved with filename: radiated photos.pdf. 3.3 Radiated Emission Data The data on the following page lists the significant emission frequencies, the limit and the margin of compliance. Numbers with a minus sign are below the limit. Judgement: Passed by 0.5 dB margin (Data transfer Mode) TEST PERSONNEL: Sign on file Jimmy Wen Engineer Typed/Printed Name April 11, 2015 Date TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 9 INTERTEK TESTING SERVICES Applicant: WARNER BROS. HOME ENTERTAINMENT INC. Model: 3000061481 Worst case operating Mode: Data transfer and transmitting Radiated Emissions (30MHz~1GHz) Polarization Horizontal Horizontal Horizontal Vertical Vertical Vertical Frequency Reading (MHz) (dBµV) 54.240 28.5 121.665 29.6 242.430 29.8 40.670 42.7 94.990 24.5 110.025 25.2 PreAmp Gain (dB) 20.0 20.0 20.0 20.0 20.0 20.0 Antenna Net Limit Factor at 3m at 3m (dB) (dBµV/m) (dBµV/m) 16.8 25.3 40.0 20.8 30.4 43.5 22.7 32.5 46.0 16.8 39.5 40.0 20.8 25.3 43.5 22.7 27.9 43.5 Margin (dB) -14.7 -13.1 -13.5 -0.5 -18.2 -15.6 NOTES: 1. Quasi-Peak detector is used for frequency up to 1GHz. 2. All measurements were made at 3 meters. Harmonic emissions not detected at the 3 meter distances were measured at 0.3- meter and an inverse proportional extrapolation was performed to compare the signal level to the 3 meter limit. No other harmonic emissions than those reported were detected at a test distance of 0.3-meter. 3. Negative value in the margin column shows emission below limit. TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 10 INTERTEK TESTING SERVICES 3.4 Conducted Emission Configuration Photograph Worst Case Conducted Configuration at 13.562 MHz (Data transfer Mode) For electronic filing, the worst case conducted emission configuration photograph is saved with filename: conducted photos.pdf. 3.5 Conducted Emission Data Judgement: Passed by 7.1 dB margin (Data transfer Mode) TEST PERSONNEL: Sign on file Jimmy Wen Engineer Typed/Printed Name April 11, 2015 Date TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 11 INTERTEK TESTING SERVICES Applicant: WARNER BROS. HOME ENTERTAINMENT INC. Model: 3000061481 Worst case operating Mode: Data transfer and transmitting Line: Live Conducted Emission Test FCC Pursuant to 15.107 Emissions Requirement Level in dBµ 80 70 60 50 40 30 20 10 0 150k FCC Part 15 Class B Voltage on Mains QP FCC Part 15 Class B Voltage on Mains AV 300 400 500 800 1M 2M 3M 4M 5M 6 8 10M Frequency in Hz 20M 30M Result Table QP Frequency (MHz) 0.166000 0.222000 QuasiPeak (dBV) 38.1 39.7 Line L1 L1 0.381000 0.650000 40.1 L1 42.1 L1 0.782000 13.562000 35.9 L1 43.6 L1 Margin (dB) 27.1 24.0 18.1 13.9 20.1 16.4 Limit (dBV) 65.2 62.7 58.2 56.0 56.0 60.0 Result Table AV Frequency Average Line (MHz) (dBV) 0.166000 32.0 L1 0.222000 32.4 L1 0.381000 34.7 L1 0.650000 28.8 L1 0.782000 24.3 L1 13.562000 42.1 L1 Margin (dB) 23.2 20.3 13.5 17.2 21.7 7.9 Limit (dBV) 55.2 52.7 48.2 46.0 46.0 50.0 TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 12 INTERTEK TESTING SERVICES Applicant: WARNER BROS. HOME ENTERTAINMENT INC. Model: 3000061481 Worst case operating Mode: Data transfer and transmitting Line: Neutral Conducted Emission Test FCC Pursuant to 15.107 Emissions Requirement Level in dBµ 80 70 60 50 40 30 20 10 0 150k FCC Part 15 Class B Voltage on Mains QP FCC Part 15 Class B Voltage on Mains AV 300 400 500 800 1M 2M 3M 4M 5M 6 8 10M Frequency in Hz 20M 30M Result Table QP Frequency (MHz) 0.154000 0.270000 QuasiPeak (dBV) 39.8 40.0 Line N N 0.382000 0.650000 40.7 N 43.9 N 0.778000 13.562000 38.8 N 44.4 N Margin (dB) 26.0 21.1 17.5 12.1 17.2 15.6 Limit (dBV) 65.8 61.1 58.2 56.0 56.0 60.0 Result Table AV Frequency (MHz) 0.154000 Average Line (dBV) 33.6 N 0.270000 33.1 N 0.382000 35.1 N 0.650000 30.4 N 0.778000 27.9 N 13.562000 42.9 N Margin (dB) 22.2 18.0 13.1 15.6 18.1 7.1 Limit (dBV) 55.8 51.1 48.2 46.0 46.0 50.0 TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 13 INTERTEK TESTING SERVICES EXHIBIT 4 EQUIPMENT PHOTOGRAPHS TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 14 INTERTEK TESTING SERVICES 4.0 Equipment Photographs For electronic filing, photographs of the tested EUT are saved with filename: external photos.pdf and internal photos.pdf. TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 15 INTERTEK TESTING SERVICES EXHIBIT 5 PRODUCT LABELLING TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 16 INTERTEK TESTING SERVICES 5.0 Product Labelling For electronics filing, the FCC ID label artwork and the label location are saved with filename: label.pdf. TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 17 INTERTEK TESTING SERVICES EXHIBIT 6 TECHNICAL SPECIFICATIONS TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 18 INTERTEK TESTING SERVICES 6.0 Technical Specifications For electronic filing, the block diagram of the tested EUT is saved with filename: block.pdf. TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 19 INTERTEK TESTING SERVICES EXHIBIT 7 INSTRUCTION MANUAL TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 20 INTERTEK TESTING SERVICES 7.0 Instruction Manual For electronic filing, a preliminary copy of the Instruction Manual is saved with filename: manual.pdf. This manual will be provided to the end-user with each unit sold / leased in the United States. TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 21 INTERTEK TESTING SERVICES EXHIBIT 8 MISCELLANEOUS INFORMATION TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 22 INTERTEK TESTING SERVICES 8.0 Miscellaneous Information This miscellaneous information includes emission measuring procedure. 8.1 Emissions Test Procedures The following is a description of the test procedure used by Intertek Test Services in the measurements of computer peripheral operating under Part 15, Subpart B rules. The test set-up and procedures described below are designed to meet the requirements of ANSI C63.4 - 2009. The computer equipment under test (EUT) is placed on a wooden turntable which is four feet in diameter and approximately one meter in height above the ground plane. During the radiated emissions test, the turntable is rotated and any cables leaving the EUT are manipulated to find the configuration resulting in maximum emissions. The antenna height and polarization are varied during the Test to search for maximum signal levels. The height of the antenna is varied from one to four meters. Detector function for radiated emissions are in QP mode from the frequency band 30MHz to 1GHz with RBW setting 120kHz. Detector function for conducted emissions are in QP & AV mode and IFBW setting is 9kHz from the frequency band 150kHz to 30MHz. For radiated emission, the frequency range scanned is 30MHz to 1GHz. For line-conducted emissions, the range scanned is 150kHz to 30MHz. TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 23 INTERTEK TESTING SERVICES 8.1 Emissions Test Procedures (cont'd) The EUT is warmed up for 15 minutes prior to the test. Conducted measurements are made as described in ANSI C63.4 - 2009. TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 24 INTERTEK TESTING SERVICES EXHIBIT 9 CONFIDENTIALITY REQUEST TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 25 INTERTEK TESTING SERVICES 9.0 Confidentiality Request For electronic filing, the confidentiality request of the tested EUT is saved with filename: request.pdf. TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 26 INTERTEK TESTING SERVICES EXHIBIT 10 TEST EQUIPMENT LIST TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 27 INTERTEK TESTING SERVICES 10.0 Test Equipment List Equipment No. SZ061-03 SZ185-01 SZ188-01 SZ062-02 SZ062-05 SZ062-12 SZ185-02 SZ187-01 SZ187-02 SZ188-03 Equipment BiConiLog Antenna EMI Receiver Anechoic Chamber RF Cable RF Cable RF Cable EMI Test Receiver Two-Line VNetwork Two-Line VNetwork Shielding Room Manufacturer ETS R&S ETS RADIALL RADIALL RADIALL R&S R&S R&S ETS Model No. 3142C ESCI RFD-F/A- 100 RG 213U 0.0426.5GHz 0.0426.5GHz ESCI ENV216 ENV216 RFD-100 Serial No. 00066460 100547 4102 ---- 100692 100072 100073 4100 Cal. Date 28-Jun-2014 10-May-2014 29-Apr-2014 03-Jan-2015 29-Oct-2014 29-Oct-2014 01-Nov-2014 01-Nov-2014 16-Jun-2014 23-Aug-2014 Due Date 28-Jun-2015 10-May-2015 29-Apr-2015 03-Jan-2016 29-Apr-2015 29-Apr-2015 01-Nov-2015 01-Nov-2015 16-Jun-2015 23-Aug-2015 TRF No.: FCC 15C_PC_b FCC ID: 2ADL5-3000061481 Report No.: SZHH00943010-002 28
Related FCC IDs:
- 2ADL5-3000061481 - Warner Bros. Home Entertainment Inc. ZEUS XBOX ONE PORTAL [-3000061481] GPL Ghostscript 9.05