Qingdao Machenike Technology Co., Ltd. GX60-2 2.4G USB Type-C Dongle 2BBT5-GX60-2 2BBT5GX602 gx60 2
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 1 Pages, 94.65KB
Document DEVICE REPORTGetApplicationAttachment.html?id=7861364FCC ID: 2BBT5-GX60-2 RF Exposure Evaluation According to KDB 447498 D01 V06 and part 2.1093Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement or numerical simulation, is not required when the corresponding SAR Test Exclusion Threshold condition(s), listed below, is (are) satisfied. For 100 MHz to 6 GHz and test separation distances 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [f(GHz)] 3.0 for 1-g SAR, and 7.5 for 10-g extremity SAR, where f(GHz) is the RF channel transmit frequency in GHz Power and distance are rounded to the nearest mW and mm before calculation The result is rounded to one decimal place for comparison EIRP=EMeas+20log(dMeas)-104.7 EIRP is the equivalent isotropically radiated power, in dBm EMeas is the field strength of the emission at the measurement distance, in dBV/m dMeas is the measurement distance, in m Here, For 2.4G Field strength (dBuV/m) 84.41 EIRP (dBm) -10.75 Max tune-up (mW) 0.08 Frequency (MHz) 2480 Min. distance(mm) 5 Calc. limit thresholds 0.03 3.0 So a SAR test is not required