Measurement Report

Kent

RF exposure report

Guangzhou Zhongxiao Maoyi Youxiangongsi CAR21 Science Kit 2A5C9-CAR21 2A5C9CAR21 car21

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 10 Pages, 380.54KB

Document DEVICE REPORTGetApplicationAttachment.html?id=6553488
FCC Test Report
Report No: FCS202305122H01 Issued for

Applicant: Address: Product Name:

Guangzhou Zhongxiao Maoyi Youxiangongsi
Nanshajie Chenghuijie 2hao 810fang Guangzhou Guangdong CN 510000
Science Kit

Brand Name:

CYOEST

Model Name:

CAR21

FCC ID:

2A5C9-CAR21

Test Standard:

FCC 47CFR §2.1093

Issued By: Flux Compliance Service Laboratory
Add: Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan
Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 2 of 10

Report No.: FCS202305122H01

TEST RESULT CERTIFICATION

Applicant's Name................... : Guangzhou Zhongxiao Maoyi Youxiangongsi

Address ................................. : Manufacture's Name.............. : Address ................................. :

Nanshajie Chenghuijie 2hao 810fang Guangzhou Guangdong CN 510000
Guangzhou Zhongxiao Trading Co.Ltd.
Room 810,No.2 Chenghui Street, Nansha Street, Nansha district, Guangzhou City,Guangdong Province, China

Product Description Product Name ....................... : Science Kit

Brand Name .......................... : CYOEST

Model Name .......................... : Series Model ......................... : Test Standards ...................... :

CAR21
XLCAR2,TANK02,TANK01,XLCAR3,NWCAR2,NWCAR3,NWCAR 4, NWCAR5,NWCAR6
FCC 47CFR §2.1093 447498 D04 Interim General RF Exposure Guidance v01

This device described above has been tested by Flux Compliance Service Laboratory, the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of Flux Compliance Service Laboratory, this document may be altered or revised by Flux Compliance Service Laboratory, personal only, and shall be noted in the revision of the document.
Date of Test...............................:

Date (s) of performance of tests.: May 12. 2023 ~ May 17. 2023

Date of Issue..............................: May 17. 2023

Test Result .................................: Pass

Tested by

:

Reviewed by

:

Approved by

:

(Scott Shen) (Duke Qian) (Jack Wang)

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 3 of 10

Report No.: FCS202305122H01

TABLE OF CONTENTS

1. GENERAL INFORMATION

5

1.1 GENERAL DESCRIPTION OF THE EUT

5

1.2 TEST FACTORY

6

2. FCC 47CFR §2.1093 REQUIREMENT

7

2.1 TEST STANDARDS

7

2.2 LIMIT

7

2.3 TEST RESULT

10

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Rev. 00

Page 4 of 10

Revision History

Issue Date May 17. 2023

Contents Initial Issue

Report No.: FCS202305122H01

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 5 of 10

Report No.: FCS202305122H01

1. GENERAL INFORMATION

1.1 GENERAL DESCRIPTION OF THE EUT

Product Name

Science Kit

Brand

CYOEST

Model Number

CAR21

Series Model(s)

XLCAR2,TANK02,TANK01,XLCAR3,NWCAR2,NWCAR3,NWCA R4, NWCAR5,NWCAR6

Model Difference Product Description Battery

Only different of model name.

The EUT is Science Kit

Operation Frequency:

433.92 MHz

Modulation Type: OOK

Antenna gain:
Antenna Designation:

0 dBi External Antenna

DC 3V from AAA battery

Hardware Version

V1.0

Software Version

V1.0

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 6 of 10

Report No.: FCS202305122H01

1.2 TEST FACTORY

Company Name: Address: Telephone:

Flux Compliance Service Laboratory
Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan
+86-769-27280901

Fax:

+86-769-27280901

FCC Test Firm Registration Number: 514908 Designation number: CN0127 A2LA accreditation number5545.01 ISED Number25801 CAB ID CN0097

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 7 of 10

Report No.: FCS202305122H01

2. FCC 47CFR §2.1093 REQUIREMENT
2.1 TEST STANDARDS Follow the maximum permissible exposure (MPE) limits specified in 447498 D04 Interim General Radio Frequency Exposure Guidelines v01. The gain of the antenna used in the product was extracted from the supplied antenna data sheet and the maximum total power input to the antenna was also measured. Calculate the distance from the product to the MPE limit by the formula. 2.2 LIMIT For single RF sources (i.e., any single fixed RF source, mobile device, or portable device, as defined in paragraph (b)(2) of this section): A single RF source is exempt if:
(A) The available maximum time-averaged power is no more than 1 mW, regardless of separation distance. This exemption may not be used in conjunction with other exemption criteria other than those in paragraph (b)(3)(ii)(A) of Part 1.1307. Medical implant devices may only use this exemption and that in paragraph (b)(3)(ii)(A);
(B) Or the available maximum time-averaged power or effective radiated power (ERP), whichever is greater, is less than or equal to the threshold Pth (mW) described in the following formula. This method shall only be used at separation distances (cm) from 0.5 centimeters to 40 centimeters and at frequencies from 0.3 GHz to 6 GHz (inclusive). Pth is given by:

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 8 of 10

Report No.: FCS202305122H01

(C) Or using below table and the minimum separation distance (R in meters) from the body of a nearby person for the frequency (f in MHz) at which the source operates, the ERP (watts) is no more than the calculated value prescribed for that frequency. For the exemption in Table 1 to apply, R must be at least /2, where  is the free-space operating wavelength in meters. If the ERP of a single RF source is not easily obtained, then the available maximum time-averaged power may be used in lieu of ERP if the physical dimensions of the radiating structure(s) do not exceed the electrical length of /4 or if the antenna gain is less than that of a half-wave dipole (1.64 linear value).

RF Source frequency (MHz)

Threshold ERP(watts)

0.3-1.34

1,920 R2.

1.34-30

3,450 R2/f2.

30-300

3.83 R2.

300-1,500

0.0128 R2f.

1,500-100,000

19.2R2.

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

Page 9 of 10

Report No.: FCS202305122H01

For multiple RF sources: Multiple RF sources are exempt if:
(A) The available maximum time-averaged power of each source is no more than 1 mW and there is a separation distance of two centimeters between any portion of a radiating structure operating and the nearest portion of any other radiating structure in the same device, except if the sum of multiple sources is less than 1 mW during the time-averaging period, in which case they may be treated as a single source (separation is not required). This exemption may not be used in conjunction with other exemption criteria other than those is paragraph (b)(3)(i)(A) of Part 1.1307. Medical implant devices may only use this exemption and that in paragraph (b)(3)(i)(A). (B) in the case of fixed RF sources operating in the same time-averaging period, or of multiple mobile or portable RF sources within a device operating in the same time averaging period, if the sum of the fractional contributions to the applicable thresholds is less than or equal to 1 as indicated in the following equation.

Where: a = number of fixed, mobile, or portable RF sources claiming exemption using paragraph (b)(3)(i)(B) of Part 1.1307 for Pth, including existing exempt transmitters and those being added. b = number of fixed, mobile, or portable RF sources claiming exemption using paragraph (b)(3)(i)(C) of Part 1.1307 for Threshold ERP, including existing exempt transmitters and those being added. c = number of existing fixed, mobile, or portable RF sources with known evaluation for the specified minimum distance including existing evaluated transmitters. Pi = the available maximum time-averaged power or the ERP, whichever is greater, for fixed, mobile, or portable RF source i at a distance between 0.5 cm and 40 cm (inclusive). Pth,i = the exemption threshold power (Pth) according to paragraph (b)(3)(i)(B) of this section for fixed, mobile, or portable RF source i. ERPj = the ERP of fixed, mobile, or portable RF source j. ERPth,j = exemption threshold ERP for fixed, mobile, or portable RF source j, at a distance of at least /2 according to the applicable formula of paragraph (b)(3)(i)(C) of Part 1.1307. Evaluatedk = the maximum reported SAR or MPE of fixed, mobile, or portable RF source k either in the device or at the transmitter site from an existing evaluation at the location of exposure. Exposure Limitk = either the general population/uncontrolled maximum permissible exposure (MPE) or specific absorption rate (SAR) limit for each fixed, mobile, or portable RF source k, as applicable from § 1.1310.
Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com

2.3 TEST RESULT Turn up Mode 433.92 MHz

Page 10 of 10
Field Strength 73.74 dBuV/m

Report No.: FCS202305122H01
EIRP -21.46dBm (+/- 1dBm)

Protocol 433.92 MHz

Fre. (GHz) 0.43392

Separation Max EIRP distance (cm) (dBm)

0.5

-18.31

Max EIRP (mW) 0.015

Limit Result
(mW) 23.17 Pass

Note: 1. EIRP(dBm)= E(dBuV/m)-95.2 2. ERP=EIRP-2.15 3. The Maxinum power is less than the limit, complies with the exemption requirements.
END OF THE REPORT

Flux Compliance Service Laboratory Room 105 Floor Bao hao Technology Building 1 NO.15 Gong ye West Road Hi-Tech Industrial, Song shan lake Dongguan Tel: 769-27280901 Fax:769-27280901 http://www.FCS-lab.com



Related FCC IDs:

Search Any Device: