( - HKA00605010-2E-\216d\227l\217\221)

TABLE OF CONTENTS/目录清单

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 11 Pages, 463.09KB

Document DEVICE REPORT0000000040
SHENZHEN HUNTKEY ELECTRIC CO., LTD

Specification For 5 Watts/

Switching Mode Power Supply

Product No./:

Model No./:HKA00605010-2E

Customer/:

File No./:

Revision/: 1

Date/: 2010-10-11

TABLE OF CONTENTS/

1. Table of Contents/ ............................. 2. Approval Sheet Cover/ .............. 3. E.C. List/ ....................................... 4. Electrical Specification/ ..................... 5. Environment Requirements/ ............... 6. Reliability Requirements/ ................. 7. EMI/EMS Standards/ ................. 8. Safety Standards/ .............................. 9. Mach. Outline Drawing/ .......................... 10. Label Drawing/ ......................................... 11. Package Drawing/ ........................... 12. Samples Test Report/ .................... 13. DC/AC Cord Drawing/DC/AC  ................. 14. Circuit Schematic Drawing/ ................... 15. Other Mach. Drawing/ .................. 16. Bill Of Material (BOM)/ .................

Prepared By :  



Checked By :  



Approved By :  



Page 0


SHENZHEN HUNTKEY ELECTRIC CO., LTD

SPECIFICATION FOR APPROVAL

CUSTOMER/



ZOOM

CUSTOMER P.N./

MODEL NO./

 HKA00605010-2E

APPROVAL NO./  WI-F-20101015

PREPARED DATE/

2010-10-11

CUSTOMER AUTHORIZED SIGNATURE/

Please return to us one copy of "SPECIFICATION FOR APPROVAL"with you
approved signature./ /.

ADD: Huntkey Park,Banxue Road,Bantian,Shenzhen,

Guangdong, P. R. China

TEL: 0755-89606666

P.C.: 518129

FAX: 0755-89606333

http://www.huntkey.com

 

 

 

Page 1


SHENZHEN HUNTKEY ELECTRIC CO., LTD

E. C. LIST/

Rev.

Description of Change/



Before/

After/

1 Original Release

---

Changed Date/

ECN No.

2010-10-11 ---

Page 2


SHENZHEN HUNTKEY ELECTRIC CO., LTD
Contents/
1. SCOPE/.....................................................................................................................................4 2. Input Characteristics/ ........................................................................................................ 4 3. Output Characteristics/ ..................................................................................................... 4 4. Protection Requirements/ ................................................................................................. 5 5. Environment Requirements/ ............................................................................................. 6 6. Reliability Requirements/ ............................................................................................. 6 7. EMI/EMS Standards/EMI/EMS  ..............................................................................................7 8. Safety Standards/ .............................................................................................................. 7 9. Mach. Outline Drawing/ ....................................................................................................... 8 10. Label Drawing/ ..................................................................................................................... 9 11. Package Drawing/ ....................................................................................................... 10
Page 3


SHENZHEN HUNTKEY ELECTRIC CO., LTD

1. SCOPE/

The document details the electrical, mechanical and environmental specifications of a SMPS,

the power supply provides 5 W continuous output power.

 5 W(),.

The power supply shall meet the RoHS requirements.

 RoHS . Description/

SMPS Adaptor(Wall mount)/

SMPS Adaptor(Desk-top)/

Open Frame/

SMPS Unit (With Case)/

Others/

2. Input Characteristics/

2.1. Input Voltage & Frequency/

The range of input voltage is from 90Vac to 264Vac with a single phase.

 90Vac  264Vac, .

Minimum/ Rating/ Maximum/

Input Voltage/ 90Vac60HZ 100Vac~240Vac

264Vac

Input Frequency/

47Hz

60Hz/50Hz

63Hz

2.2. Input AC Current/ 0.25Amax. @ 90Vac input & Full load/ 90Vac  0.25A
2.3. Inrush Current (cold start)/()

30Amax. @ 132Vac input/ 132Vac  30A

40Amax. @ 264Vac input/ 264Vac  40A 2.4. Average Efficiency /

While input 115Vac and 230Vac,the average efficiency is more than 68.3%.The test point

is at 25%,50%,75% and 100% of max load respectively.

 115Vac  230Vac  68.3% 25%,50%,75% 100%
2.5. No-Load Input Power Dissipation/

While input 115Vac or 230Vac and the output is no load, the input power loss must be

less than 0.30W.

 115Vac/230Vac 0.30W.

3. Output Characteristics/

3.1. Static Output Characteristics <Vo & R+N>/<&+>

Output Rated Load/ Peak Output Range

R+N Remark

Rating Min. Load Max. Load Load    

+5.0V

0A

1.0A

/

4.75V ~ 5.25V 120mVp-p

Page 4



SHENZHEN HUNTKEY ELECTRIC CO., LTD

Ripple & Noise: Tested by a oscilloscope using 20MHz bandwidth and the output is paralleled a 0.1uF ceramic capacitor and a 10uF electrolysis capacitor. (Under the input

Voltage 100~240Vac)
:  20MHz , 0.1uF  10uF  ( 100~240Vac)
3.2. Line/ Load Regulation//

Output Rating

Load Condition/ Line Regulation Load Regulation Remark

Min. Load Max. Load 



 

+5.0V

0A

1.0A

± 2%

± 5%

3.3. Turn - on Delay Time/

2S max. @ 90Vac input & Full load/ 90Vac  2S

3.4. Hold-up Time/

10mS min. @ Full load &115Vac/60Hz input turn off at worst case
 115Vac , 10mS
10mS min. @ Full load &230Vac/50Hz input turn off at worst case
 230Vac , 10mS
3.5. Rise Time/ 30mS max. @ Full load/ 30mS
3.6. Fall Time/ 20mS max. @ Full load/ 20mS
3.7. Output Overshoot / Undershoot// 10% max. When the power on or off/ 10%
3.8. Output Load Transient Response/

Output voltage is within 4.5~5.5V while the load step is from 20% to 80% of max load, R/S: 0.5A/uS, frequency: 100Hz, and 8mS duration at 80% of max load.
 4.5~5.5V ,:  20% 80%,: 0.5A/uS,: 100Hz, 80%  8mS.

4. Protection Requirements/

4.1. Over Current Protection/ OCP Point Range: <200% of Max. Load/:  200% The output shall hiccup when the over current applied to the output, and shall be self-recovery when the fault condition is removed
,,,
4.2. Short Circuit Protection/ The input power shall decrease when the output is short to GND, the power supply shall not damage, and shall be self-recovery when the fault condition is removed
,,,
4.3. Over Voltage Protection/ The power supply shall be protected when the output is over voltage, and the power

Page 5


SHENZHEN HUNTKEY ELECTRIC CO., LTD supply shall not be damaged.
,
5. Environment Requirements/
5.1. Operating Temperature and Relative Humidity/ 0 to +40 10%RH to 90%RH
5.2. Storage Temperature and Relative Humidity/ -40 to +70 5%RH to 95%RH non-condensing @ Sea level shall below 10,000 feet
 10,000 -40  +70 , 10%RH to 90%RH
5.3. Vibration/ 10 to 300Hz sweep at a constant acceleration of 1.0G(Breadth: 3.5mm) for 1Hour for each of the perpendicular axes X, Y, Z : 10 to 300Hz, : 1.0G(: 3.5mm), X, Y, Z  1 
5.4. Drop in/ 1 Corner, 3 Edges, 6 Surfaces each once. Drop on the cement plane, Height: 100cm,
1 , 3 , 6  1 : 100 
6. Reliability Requirements/
6.1. MTBF Qualification/ 6.2.1 The MTBF Prediction shall be at least 300,000hours at 40, Full load and normal input
conditionStandardsTelecordia SR-332, Issue 2
 300,000 ,40Telecordia SR-332, Issue 2
6.2.2 The MTBF Demonstration shall be at least 30,000hours at 40, Full load and normal input conditionStandardsMIL-STD-781C
 30,000 ,40 MIL-STD-781C
Page 6


SHENZHEN HUNTKEY ELECTRIC CO., LTD
7. EMI/EMS Standards/EMI/EMS 
7.1. EMI Standards/EMI  EN 55022:1998, +A1:2000 +A2:2003, Class B CISPR 22:2003, Class B AS/NZS CISPR 22: 2004, Class B

7.2. EMS Standards/EMS  EN 61000-3-2 Harmonic current emissions EN 61000-3-3 Voltage fluctuations & flicker EN 61000-4-2 Electrostatic Discharge(ESD): 8kV air discharge, 6kV contact discharge EN 61000-4-3 Radio-Frequency Electromagnetic Field Susceptibility Test-RS EN 61000-4-4 Electrical Fast Transient/Burst-EFT EN 61000-4-5 Surge Immunity Test: AC Power Line: line to line 2.5kV, line to earth 4kV EN 61000-4-6 Conducted Radio Frequency Disturbances Test-CS EN 61000-4-8 Power Frequency Magnetic Field Test EN 61000-4-11 Voltage Dips

8. Safety Standards/

8.1. Dielectric Strength(Hi-pot)/()

Primary to Secondary: 3000Vac / 3.5mA / 60 seconds(3 seconds for production)

or 4242Vdc / 3.5mA / 60 seconds(3 seconds for production)

: 3000Vac / 3.5mA / 60 (: 3 )

 4242Vdc / 3.5mA / 60 (: 3 ) 8.2. Leakage Current/
0.25mAmax. at 264Vac / 50Hz input/ 264Vac/50Hz  0.25mA 8.3. Insulation Resistance/

20M min. @ primary to secondary add a 500Vdc test voltage

 500Vdc , 20M
8.4. Regulatory Standards/

Type  UL/CUL  TUV  CCC  CE

Country USA Europe China Europe

Standard UL60950-1 EN60950-1 GB4943 EN60950-1

Type  PSB  PSE  NOM  GOST

Country Standard Singapore IEC60950-1 Japan J60950 Mexico NOM-001 Russia MEK60950

Page 7


SHENZHEN HUNTKEY ELECTRIC CO., LTD
9. Mach. Outline Drawing/
Page 8

10. Label Drawing/


SHENZHEN HUNTKEY ELECTRIC CO., LTD

Page 9

11. Package Drawing/


SHENZHEN HUNTKEY ELECTRIC CO., LTD

Page 10


PrimoPDF PrimoPDF http://www.primopdf.com/

Search Any Device: