CE RF TEST REPORT

X

MPE

Haier US Appliance Solutions, Inc. BLEC001 BT Module Ph2 with harness connection ZKJ-BLEC001 ZKJBLEC001 blec001

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 10 Pages, 433.37KB

Document DEVICE REPORTGetApplicationAttachment.html?id=3625711
REPORT No.SZ17090131S01

RF EXPOSURE EVALUATION REPORT

APPLICANT

: Haier US Appliance Solutions, Inc.

PRODUCT NAME : BT Module Ph2 with harness connection

MODEL NAME

: 191D9618G001

TRADE NAME

:

BRAND NAME FCC ID STANDARD(S) ISSUE DATE

: Haier
: ZKJ-BLEC001 47CFR 2.1093
: KDB 447498 D01 General RF Exposure Guidance v06
: 2017-10-10

SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.

NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for validation and information confirmed at our website.

MORLAB GROUP

FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.com

Fax: 86-755-36698525 E-mail: [email protected]

REPORT No.SZ17090131S01

DIRECTORY
TEST REPORT DECLARATION·····················································································································3
1. TECHNICAL INFORMATION ····················································································································4
1.1. IDENTIFICATION OF APPLICANT···················································································································4 1.2. IDENTIFICATION OF MANUFACTURER ·········································································································4 1.3. EQUIPMENT UNDER TEST (EUT) ·················································································································4 1.3.1. PHOTOGRAPHS OF THE EUT ························································································································5 1.3.2. IDENTIFICATION OF ALL USED EUT ·············································································································6 1.4. APPLIED REFERENCE DOCUMENTS ·············································································································6
2. DEVICE CATEGORY AND RF EXPOSURE LIMIT ················································································7
3.MEASUREMENT OF CONDUCTED PEAK OUTPUT POWER ·····························································8
4. RF EXPOSURE EVALUATION····················································································································9
ANNEX A GENERAL INFORMATION ········································································································10

Issue 1.0

Date 2017-10-10

Change History Reason for change First edition

MORLAB GROUP FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.com

Fax: 86-755-36698525 E-mail: [email protected]
Page 2 0f 10

REPORT No.SZ17090131S01

TEST REPORT DECLARATION

Applicant

Haier US Appliance Solutions, Inc.

Applicant Address

Appliance Park AP5-2N-67, Louisville, KY, United States (Zip Code : 40225)

Manufacturer

iTON Technology Corp.

7 Floor EastBuilding C, No. 1006 Shennan Road, Shenzhen Manufacturer Address International Innovation Certer, Shenzhen, China.

Product Name

BT Module Ph2 with harness connection

Model Name

191D9618G001

Brand Name

Haier

HW Version

Ver 1.1

SW Version Test Standards Issue Date

1.0 47CFR 2.1093; KDB 447498 D01 General RF Exposure Guidance v06
2017-10-10

SAR Evaluation

Not Required

Tested by

:

Approved by :

Peng Fuwei (Test engineer) Peng Huarui (Supervisor)

MORLAB GROUP FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.com

Fax: 86-755-36698525 E-mail: [email protected]
Page 3 0f 10

REPORT No.SZ17090131S01

1. TECHNICAL INFORMATION

Note: the following data is based on the information by the applicant.

1.1. Identification of Applicant

Company Name: Address:

Haier US Appliance Solutions, Inc. Appliance Park AP5-2N-67, Louisville, KY, United States (Zip Code : 40225)

1.2. Identification of Manufacturer

Company Name: Address:

iTON Technology Corp. 7 Floor EastBuilding C, No. 1006 Shennan Road, Shenzhen International Innovation Certer, Shenzhen, China.

1.3. Equipment Under Test (EUT)

Model Name:

191D9618G001

Trade Name:

Brand Name: Hardware Version: Software Version: Frequency Bands: Modulation Mode: Antenna Type: Antenna Gain:

Haier Ver 1.1 1.0 Bluetooth 4.2:2402-2480MHz; Bluetooth 4.2: GFSK; PCB Antenna 1.43 dBi

MORLAB GROUP FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.com

Fax: 86-755-36698525 E-mail: [email protected]
Page 4 0f 10

1.3.1. Photographs of the EUT 1. EUT front view

REPORT No.SZ17090131S01

2. EUT rear view

MORLAB GROUP FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.com

Fax: 86-755-36698525 E-mail: [email protected]
Page 5 0f 10

REPORT No.SZ17090131S01

1.3.2. Identification of all used EUT
The EUT identity consists of numerical and letter characters, the letter character indicates the test sample, and the following two numerical characters indicate the software version of the test sample.

EUT Identity
1#

Hardware Version Ver 1.1

Software Version 1.0

1.4. Applied Reference Documents

Leading reference documents for testing:

No. Identity

Document Title

1

47 CFR§2.1093

Radiofrequency Radiation Exposure Evaluation: portable

devices

2

KDB 447498 D01v06

General RF Exposure Guidance

MORLAB GROUP FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.com

Fax: 86-755-36698525 E-mail: [email protected]
Page 6 0f 10

REPORT No.SZ17090131S01

2. DEVICE CATEGORY AND RF EXPOSURE LIMIT

Per user manual, Based on 47CFR 2.1091, this device belongs to mobile device category with General Population/Uncontrolled exposure. Mobile Devices: 47CFR 2.1091(b) For purposes of this section, a mobile device is defined as a transmitting device designed to be used in other than fixed locations and to generally be used in such a way that a separation distance of at least 20 centimeters is normally maintained between the transmitter's radiating structure(s) and the body of the user or nearby persons. In this context, the term "fixed location" means that the device is physically secured at one location and is not able to be easily moved to another location. Transmitting devices designed to be used by consumers or workers that can be easily re-located, such as wireless devices associated with a personal computer, are considered to be mobile devices if they meet the 20 centimeter separation requirement. GENERAL POPULATION / UNCONTROLLED EXPOSURE The general population/uncontrolled exposure limits are applicable to situations in which the general public may be exposed or in which persons who are exposed as a consequence of their employment may not be made fully aware of the potential for exposure or cannot exercise control over their exposure. Members of the general public would come under this category when exposure is not employment-related; for example, in the case of a wireless transmitter that exposes persons in its vicinity. Warning labels placed on low-power consumer devices such as cellular telephones are not considered sufficient to allow the device to be considered under the occupational/controlled category, and the general population/uncontrolled exposure limits apply to these devices.
TABLE 1--LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)

Frequency range (MHz)

Electric field strength (V/m)

Magnetic field strength (A/m)

Power density (mW/cm2)

Averaging time
(minutes)

(B) Limits for General Population/Uncontrolled Exposure

0.3-1.34 1.34-30

614 824/f

1.63 2.19/f

*(100)

30

*(180/f2)

30

30-300

27.5

0.073

0.2

30

300-1500

-

-

f/1500

30

1500-100,000

-

f = frequency in MHz

-

1.0

30

* = Plane-wave equivalent power density

MORLAB GROUP FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.com

Fax: 86-755-36698525 E-mail: [email protected]
Page 7 0f 10

REPORT No.SZ17090131S01

3.MEASUREMENT OF CONDUCTED PEAK OUTPUT POWER
1. Bluetooth Peak output power

Band

Channel

0 BT
39 4.2+EDR
78

GFSK
8.19 7.68 6.98

Output Power(dBm)

/4-DQPSK
7.32 7.13 6.62

8-DPSK
7.71 7.49 6.95

Band BT4.2

Frequency Channel
(MHz)

0

2402

19

2440

39

2480

Output Power(dBm)
GFSK
5.79 5.87 5.52

MORLAB GROUP FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.com

Fax: 86-755-36698525 E-mail: [email protected]
Page 8 0f 10

REPORT No.SZ17090131S01

4. RF EXPOSURE EVALUATION
Standalone transmission MPE evaluation

Bands

Frequency (MHz)

Antenna Gain (dBi)

Conducted Time-averaging

Average Power

EIRP

(dBm)

(mW)

Power density (mW/cm²)

Bluetooth

2402

1.43

8.50

4.92

0.0010

1. MPE calculation method Power Density = EIRP/4R²
Where: EIRP = P·G P = Peak out power G = Antenna gain R = Separation distance (20cm)

Limit for MPE
(mW/cm²)
1.0

MORLAB GROUP FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.com

Fax: 86-755-36698525 E-mail: [email protected]
Page 9 0f 10

REPORT No.SZ17090131S01

ANNEX A GENERAL INFORMATION

1. Identification of the Responsible Testing Laboratory

Company Name:

Shenzhen Morlab Communications Technology Co., Ltd.

Department:

Morlab Laboratory

Address:

FL.3, Building A, FeiYang Science Park, No.8 LongChang

Road, Block 67, BaoAn District, ShenZhen, GuangDong

Province, P. R. China

Responsible Test Lab Manager: Mr. Su Feng

Telephone:

+86 755 36698555

Facsimile:

+86 755 36698525

2. Identification of the Responsible Testing Location

Name: Address:

Shenzhen Morlab Communications Technology Co., Ltd. Morlab Laboratory FL.3, Building A, FeiYang Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R. China

***** END OF REPORT *****

MORLAB GROUP FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road, Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China

Tel: 86-755-36698555 Http://www.morlab.com

Fax: 86-755-36698525 E-mail: [email protected]
Page 10 0f 10



Related FCC IDs: