CommerCial PaCkaged rooftoPs
easier to sell Designed with streamlined installation in mind, KeepRite commercial packaged rooftops have everything you need from handled access doors to certified and pre-engineered factory-installed options as well as field
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 4 Pages, 2.43MB
Document DEVICE REPORT12keepri9136-1 M2reb Commercial Roof webCommercial Packaged Rooftops 325 Tons EFRIGERANT ENTALLY SOUND R ENVIRONM Commercial Packaged Rooftops Easier To Sell Designed with streamlined installation in mind, KeepRite® commercial packaged rooftops have everything you need from handled access doors to certified and pre-engineered factory-installed options as well as fieldinstalled accessories. KeepRite rooftop units are available in gas heating/ electric cooling, electric heat/electric cooling or packaged heat pumps and deliver SEER ratings as high as 13.4 and EER ratings up to 11.3 on standard efficiency units (RGS/RAS/RHS) and SEER ratings as high as 15.8 and EER ratings up to 12.4 on high efficiency models (RGH/RAH/ RHH). KeepRite rooftops have the capability for vertical or horizontal airflow for fast and easy installation. Highefficiency gas heating (up to 82% efficiency) with induced draft design facilitates long life and safe operation. KeepRite rooftops can easily satisfy nearly any light commercial application need. S EER stands for Seasonal Energy Efficiency Ratio and EER stands for Energy Efficiency Ratio. Easier To Service Scroll Compressor KeepRite rooftop units utilize fully hermetic scroll compressors. Compressors are designed with internal isolation and have internal thermal line break, current overload, and high-pressure differential protection. Central Terminal Board Standard on every unit, the integrated terminal simplifies the installation of pre-engineered and certified field-installed accessories, including economizers, by providing clearly labeled connection points for easy plug-in connection. Easy-Access Handles Handles located on all major access panels provide quick, convenient and safe access to components for easy maintenance and service. No-Strip Screw Collars To prevent misalignment and stripped metal panels, screws are guided into collars. This increased screw engagement also makes panels easier to remove and replace. Unit Safety Protection For increased reliability, heat pump models come standard with a refrigerant suction line accumulator in each refrigerant circuit. This preventive measure stops the natural tendency of liquid refrigerant from entering the compressor in heat pumps as they switch in and out of defrost, and between heating and cooling modes. In addition, heat pump models come with high pressure and temperature protection as well as low pressure or loss of charge protection. Easier To Install · KeepRite rooftops were designed with streamlined installation in mind--whether it's for replacement or new construction. · The light and compact design has full-perimeter base rails that help in moving, transporting and rigging. · KeepRite models up to 12.5 tons are specifically designed to fit on many similar roof curbs dating back over 20 years, which makes replacement easy and eliminates the need for curb adapters or changing utility connections. · KeepRite rooftops are capable of either vertical or horizontal airflow to meet nearly every application need. · KeepRite rooftops can be ordered with a wide range of factory pre-engineered and certified options like stainless steel heat exchangers, smoke detectors and economizers. Other factory-installed options include convenience outlets, non-fused disconnects, motorized two-position dampers, and medium and high static motor drive. ENTALLY SOUND R EFRIGERANT R410A is an EPA-approved, environmentally sound refrigerant. ENVIRONM Gas Heating/Electric Cooling Models RGS Nominal Cooling Ton Size Cooling Stages AHRI Efficiency (SEER) EER Dimensions (in.) L x W x H 3 1 (13.0) 74 x 47 x 33 4 1 (13.0) 74 x 47 x 33 5 1 (13.0) 74 x 47 x 33 6 1 11.0 74 x 47 x 41 7.5 1 11.0 88 x 59 x 41 7.5 2 11.0 88 x 59 x 41 8.5 1 11.0 88 x 59 x 49 8.5 2 11.0 88 x 59 x 49 10 1 11.0 88 x 59 x 49 10 2 11.1 88 x 59 x 49 12.5 2 10.8 88 x 59 x 49 15 2 10.8 116 x 63 x 57 17.5 2 10.8 128 x 87 x 49 20 2 9.8 141 x 87 x 49 25 2 9.8 141 x 87 x 57 * 27.5 2 10.2 158 x 87 x 57 Gas Heat--Heating Input (MBTUH) Low Medium High 72 115 72 115 150 72 115 150 72 115 150 125 180 224 125 180 224 125 180 224 125 180 224 180 224 250 180 224 250 180 224 250 180 240 350 220 310 400 220 310 400 220 310 400 220 310 400 Approx. Unit Weight (lbs.) 483 537 569 652 780 835 920 930 930 940 1167 1380 2286 2436 2561 2640 Standard Efficiency Commercial Packaged Rooftops Electric Heat/Electric Cooling & Cooling Only Models RAS Nominal Cooling Ton Size Cooling Stages AHRI Efficiency (SEER) EER Dimensions (in.) L x W x H 3 1 (13.0) 74 x 47 x 33 4 1 (13.0) 74 x 47 x 33 5 1 (13.0) 74 x 47 x 33 6 1 11.2 74 x 47 x 41 7.5 1 11.2 88 x 59 x 41 7.5 2 11.2 88 x 59 x 41 8.5 1 11.2 88 x 59 x 49 8.5 2 11.2 88 x 59 x 49 10 1 11.2 88 x 59 x 49 10 2 11.3 88 x 59 x 49 12.5 2 11.0 88 x 59 x 49 15 2 11.0 116 x 63 x 57 17.5 2 11.0 128 x 87 x 49 20 2 10.0 141 x 87 x 49 25 2 10.0 141 x 87 x 57 * 27.5 2 10.4 158 x 87 x 57 Electrical Heat Nominal KW Range 4.0 to 16.0 4.4 to 23.0 6.5 to 26.5 6.0 to 26.5 10.4 to 42.4 10.4 to 42.4 10.4 to 42.4 10.4 to 42.4 10.4 to 51.0 10.4 to 51.0 10.4 to 51.0 16.5 to 67.0 25.0 to 75.0 25.0 to 75.0 25.0 to 75.0 25.0 to 75.0 Approx. Unit Weight (lbs.) 438 494 524 607 705 760 845 855 855 865 1075 1305 2159 2197 2434 2513 Packaged Heat Pump Models RHS Nominal Cooling Ton Size Cooling Stages AHRI Efficiency (SEER) EER Dimensions (in.) L x W x H 3 1 (13.4) 74 x 47 x 33 4 1 (13.1) 74 x 47 x 33 5 1 (13.2) 74 x 47 x 41 6 1 11.1 74 x 47 x 41 7.5 2 11.2 88 x 59 x 49 8.5 2 11.2 88 x 59 x 49 10 2 11.0 88 x 59 x 49 12.5 2 10.6 116 x 63 x 57 15 2 10.8 128 x 86 x 49 20 2 10.5 141 x 86 x 49 @ 47° F Heating Capacity (HSPF) COP 35,600 (7.70) 45,500 (7.70) 58,000 (7.70) 67,000 3.30 86,000 3.40 96,000 3.30 116,000 3.40 142,000 3.20 166,000 3.30 220,000 3.30 *Coming Soon @ 17° F Heating Capacity (HSPF) COP 18,200 (N/A) 23,600 (N/A) 31,200 (N/A) 34,800 2.25 48,000 2.25 54,500 2.25 62,300 2.25 76,000 2.05 103,000 2.40 134,000 2.30 Approx. Unit Weight (lbs.) 505 510 590 630 885 910 1050 1370 1775 2100 High Efficiency Commercial Packaged Rooftops Gas Heating/Electric Cooling Models RGH Nominal Cooling Ton Size 3 4 5 6 7.5 8.5 10 12.5 15 17.5 20 25 Cooling Stages 1 1 1 1 2 2 2 2 2 2 2 2 AHRI Efficiency (SEER) EER (15.0) (15.6) (15.2) 12.0 12.0 12.0 11.5 12.2 12.0 12.0 12.0 11.2 Dimensions (in.) L x W x H 74 x 47 x 33 74 x 47 x 41 74 x 47 x 41 88 x 59 x 41 88 x 59 x 49 88 x 59 x 49 88 x 59 x 49 116 x 63 x 57 128 x 87 x 49 141 x 87 x 49 141 x 87 x 57 158 x 87 x 57 Gas Heat--Heating Input (MBTUH) Low Medium High 72 115 72 115 150 72 115 150 72 125 150 125 180 224 125 180 224 180 224 250 150 180 240 220 310 400 220 310 400 220 310 400 220 310 400 Approx. Unit Weight (lbs.) 505 590 600 765 925 925 1099 1430 1892 2102 2247 2292 Electric Heat/Electric Cooling & Cooling Only Models RAH Nominal Cooling Ton Size Cooling Stages AHRI Efficiency (SEER) EER Dimensions (in.) L x W x H 3 1 (15.0) 74 x 47 x 33 4 1 (15.6) 74 x 47 x 41 5 1 (15.2) 74 x 47 x 41 6 1 12.2 88 x 59 x 41 7.5 2 12.2 88 x 59 x 49 8.5 2 12.2 88 x 59 x 49 10 2 11.7 88 x 59 x 49 12.5 15 17.5 2 12.4 116 x 63 x 57 2 12.2 128 x 87 x 49 2 12.2 141 x 87 x 49 20 2 12.2 141 x 87 x 57 25 2 11.4 158 x 87 x 57 Electrical Heat Nominal KW Range 4.4 to 16.0 4.4 to 23.0 6.5 to 26.5 6.0 to 26.5 10.4 to 42.4 10.4 to 42.4 10.4 to 51.0 16.5 to 50.0 25.0 to 75.0 25.0 to 75.0 25.0 to 75.0 25.0 to 75.0 Approx. Unit Weight (lbs.) 458 545 550 715 860 860 1025 1360 1793 2003 2148 2193 Packaged Heat Pump Models RHH Nominal Cooling Ton Size Cooling Stages AHRI Efficiency (SEER) EER Dimensions (in.) L x W x H 3 1 (15.6) 74 x 47 x 33 4 1 (15.8) 74 x 47 x 41 5 1 (15.0) 74 x 47 x 41 6 1 12.0 88 x 59 x 41 7.5 2 12.1 88 x 59 x 49 8.5 2 12.0 88 x 59 x 49 10 2 12.3 116 x 63 x 57 @ 47° F Heating Capacity (HSPF) COP 34,000 (8.00) 46,000 (8.10) 55,000 (8.20) 70,000 3.40 84,000 3.50 100,000 3.40 116,000 3.50 @ 17° F Heating Capacity (HSPF) COP 18,400 (N/A) 23,800 (N/A) 28,600 (N/A) 39,000 2.40 47,000 2.40 56,000 2.26 65,000 2.40 Approx. Unit Weight (lbs.) 495 580 610 710 875 1020 1390 ® THE PROS KNOW PO Box 128 Lewisburg, TN 37091 KeepRite.com RGS/RAS/RHS/RGH/RAH/RHH Series © 2012 International Comfort Products, LLC All systems tested and listed by the appropriate agencies. As part of its commitment to quality, International Comfort Products, LLC, reserves the right to change specifications on its products without notice. Illustrations and photographs in this brochure are only representative. Some product models may vary. Part No. 401-39-1320-00 Printed 09/12Adobe PDF Library 9.9 Adobe InDesign CS5.5 (7.5.3)