CommerCial PaCkaged rooftoPs

easier to sell Designed with streamlined installation in mind, KeepRite commercial packaged rooftops have everything you need from handled access doors to certified and pre-engineered factory-installed options as well as field

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 4 Pages, 2.43MB

Document DEVICE REPORT12keepri9136-1 M2reb Commercial Roof web
Commercial Packaged Rooftops
3­25 Tons
EFRIGERANT

ENTALLY SOUND R

ENVIRONM

Commercial Packaged Rooftops

Easier To Sell
Designed with streamlined installation in mind, KeepRite® commercial packaged rooftops have everything you need from handled access doors to certified and pre-engineered factory-installed options as well as fieldinstalled accessories.
KeepRite rooftop units are available in gas heating/ electric cooling, electric heat/electric cooling or packaged heat pumps and deliver SEER ratings as high as 13.4 and EER ratings up to 11.3 on standard efficiency units (RGS/RAS/RHS) and SEER ratings as high as 15.8 and EER ratings up to 12.4 on high efficiency models (RGH/RAH/ RHH). KeepRite rooftops have the capability for vertical or horizontal airflow for fast and easy installation. Highefficiency gas heating (up to 82% efficiency) with induced draft design facilitates long life and safe operation. KeepRite rooftops can easily satisfy nearly any light commercial application need.
S EER stands for Seasonal Energy Efficiency Ratio and EER stands for Energy Efficiency Ratio.
Easier To Service
Scroll Compressor
KeepRite rooftop units utilize fully hermetic scroll compressors. Compressors are designed with internal isolation and have internal thermal line break, current overload, and high-pressure differential protection.
Central Terminal Board
Standard on every unit, the integrated terminal simplifies the installation of pre-engineered and certified field-installed accessories, including economizers, by providing clearly labeled connection points for easy plug-in connection.
Easy-Access Handles
Handles located on all major access panels provide quick, convenient and safe access to components for easy maintenance and service.

No-Strip Screw Collars
To prevent misalignment and stripped metal panels, screws are guided into collars. This increased screw engagement also makes panels easier to remove and replace.

Unit Safety Protection
For increased reliability, heat pump models come standard with a refrigerant suction line accumulator in each refrigerant circuit. This preventive measure stops the natural tendency of liquid refrigerant from entering the compressor in heat pumps as they switch in and out of defrost, and between heating and cooling modes. In addition, heat pump models come with high pressure and temperature protection as well as low pressure or loss of charge protection.

Easier To Install
· KeepRite rooftops were designed with streamlined installation in mind--whether it's for replacement or new construction.
· The light and compact design has full-perimeter base rails that help in moving, transporting and rigging.
· KeepRite models up to 12.5 tons are specifically designed to fit on many similar roof curbs dating back over 20 years, which makes replacement easy and eliminates the need for curb adapters or changing utility connections.
· KeepRite rooftops are capable of either vertical or horizontal airflow to meet nearly every application need.
· KeepRite rooftops can be ordered with a wide range of factory pre-engineered and certified options like stainless steel heat exchangers, smoke detectors and economizers. Other factory-installed options include convenience outlets, non-fused disconnects, motorized two-position dampers, and medium and high static motor drive.

ENTALLY SOUND R

EFRIGERANT

R410A is an EPA-approved,

environmentally sound refrigerant.

ENVIRONM

Gas Heating/Electric Cooling Models ­ RGS

Nominal Cooling Ton Size

Cooling Stages

AHRI Efficiency (SEER) EER

Dimensions (in.) L x W x H

3

1

(13.0)

74 x 47 x 33

4

1

(13.0)

74 x 47 x 33

5

1

(13.0)

74 x 47 x 33

6

1

11.0

74 x 47 x 41

7.5

1

11.0

88 x 59 x 41

7.5

2

11.0

88 x 59 x 41

8.5

1

11.0

88 x 59 x 49

8.5

2

11.0

88 x 59 x 49

10

1

11.0

88 x 59 x 49

10

2

11.1

88 x 59 x 49

12.5

2

10.8

88 x 59 x 49

15

2

10.8

116 x 63 x 57

17.5

2

10.8

128 x 87 x 49

20

2

9.8

141 x 87 x 49

25

2

9.8

141 x 87 x 57

* 27.5

2

10.2

158 x 87 x 57

Gas Heat--Heating Input (MBTUH)

Low

Medium

High

72

115

­

72

115

150

72

115

150

72

115

150

125

180

224

125

180

224

125

180

224

125

180

224

180

224

250

180

224

250

180

224

250

180

240

350

220

310

400

220

310

400

220

310

400

220

310

400

Approx. Unit Weight (lbs.)
483 537 569 652 780 835 920 930 930 940 1167 1380 2286 2436 2561 2640

Standard Efficiency Commercial Packaged Rooftops

Electric Heat/Electric Cooling & Cooling Only Models ­ RAS

Nominal Cooling Ton Size

Cooling Stages

AHRI Efficiency (SEER) EER

Dimensions (in.) L x W x H

3

1

(13.0)

74 x 47 x 33

4

1

(13.0)

74 x 47 x 33

5

1

(13.0)

74 x 47 x 33

6

1

11.2

74 x 47 x 41

7.5

1

11.2

88 x 59 x 41

7.5

2

11.2

88 x 59 x 41

8.5

1

11.2

88 x 59 x 49

8.5

2

11.2

88 x 59 x 49

10

1

11.2

88 x 59 x 49

10

2

11.3

88 x 59 x 49

12.5

2

11.0

88 x 59 x 49

15

2

11.0

116 x 63 x 57

17.5

2

11.0

128 x 87 x 49

20

2

10.0

141 x 87 x 49

25

2

10.0

141 x 87 x 57

* 27.5

2

10.4

158 x 87 x 57

Electrical Heat Nominal KW Range 4.0 to 16.0 4.4 to 23.0 6.5 to 26.5 6.0 to 26.5
10.4 to 42.4 10.4 to 42.4 10.4 to 42.4 10.4 to 42.4 10.4 to 51.0 10.4 to 51.0 10.4 to 51.0 16.5 to 67.0 25.0 to 75.0 25.0 to 75.0 25.0 to 75.0 25.0 to 75.0

Approx. Unit Weight (lbs.)
438 494 524 607 705 760 845 855 855 865 1075 1305 2159 2197 2434 2513

Packaged Heat Pump Models ­ RHS

Nominal Cooling Ton Size

Cooling Stages

AHRI Efficiency (SEER) EER

Dimensions (in.) L x W x H

3

1

(13.4)

74 x 47 x 33

4

1

(13.1)

74 x 47 x 33

5

1

(13.2)

74 x 47 x 41

6

1

11.1

74 x 47 x 41

7.5

2

11.2

88 x 59 x 49

8.5

2

11.2

88 x 59 x 49

10

2

11.0

88 x 59 x 49

12.5

2

10.6

116 x 63 x 57

15

2

10.8

128 x 86 x 49

20

2

10.5

141 x 86 x 49

@ 47° F

Heating Capacity

(HSPF) COP

35,600

(7.70)

45,500

(7.70)

58,000

(7.70)

67,000

3.30

86,000

3.40

96,000

3.30

116,000

3.40

142,000

3.20

166,000

3.30

220,000

3.30

*Coming Soon

@ 17° F

Heating Capacity

(HSPF) COP

18,200

(N/A)

23,600

(N/A)

31,200

(N/A)

34,800

2.25

48,000

2.25

54,500

2.25

62,300

2.25

76,000

2.05

103,000

2.40

134,000

2.30

Approx. Unit Weight (lbs.)
505 510 590 630 885 910 1050 1370 1775 2100

High Efficiency Commercial Packaged Rooftops

Gas Heating/Electric Cooling Models ­ RGH

Nominal Cooling Ton Size
3 4 5 6 7.5 8.5 10 12.5 15 17.5 20 25

Cooling Stages
1 1 1 1 2 2 2 2 2 2 2 2

AHRI Efficiency (SEER) EER
(15.0) (15.6) (15.2) 12.0 12.0 12.0 11.5 12.2 12.0 12.0 12.0 11.2

Dimensions (in.) L x W x H
74 x 47 x 33 74 x 47 x 41 74 x 47 x 41 88 x 59 x 41 88 x 59 x 49 88 x 59 x 49 88 x 59 x 49 116 x 63 x 57 128 x 87 x 49 141 x 87 x 49 141 x 87 x 57 158 x 87 x 57

Gas Heat--Heating Input (MBTUH)

Low

Medium

High

72

115

­

72

115

150

72

115

150

72

125

150

125

180

224

125

180

224

180

224

250

150

180

240

220

310

400

220

310

400

220

310

400

220

310

400

Approx. Unit Weight (lbs.)
505 590 600 765 925 925 1099 1430 1892 2102 2247 2292

Electric Heat/Electric Cooling & Cooling Only Models ­ RAH

Nominal Cooling Ton Size

Cooling Stages

AHRI Efficiency (SEER) EER

Dimensions (in.) L x W x H

3

1

(15.0)

74 x 47 x 33

4

1

(15.6)

74 x 47 x 41

5

1

(15.2)

74 x 47 x 41

6

1

12.2

88 x 59 x 41

7.5

2

12.2

88 x 59 x 49

8.5

2

12.2

88 x 59 x 49

10

2

11.7

88 x 59 x 49

12.5 15 17.5

2

12.4

116 x 63 x 57

2

12.2

128 x 87 x 49

2

12.2

141 x 87 x 49

20

2

12.2

141 x 87 x 57

25

2

11.4

158 x 87 x 57

Electrical Heat Nominal KW Range
4.4 to 16.0 4.4 to 23.0 6.5 to 26.5 6.0 to 26.5 10.4 to 42.4 10.4 to 42.4 10.4 to 51.0 16.5 to 50.0 25.0 to 75.0 25.0 to 75.0 25.0 to 75.0 25.0 to 75.0

Approx. Unit Weight (lbs.)
458 545 550 715 860 860 1025 1360 1793 2003 2148 2193

Packaged Heat Pump Models ­ RHH

Nominal Cooling Ton Size

Cooling Stages

AHRI Efficiency (SEER) EER

Dimensions (in.) L x W x H

3

1

(15.6)

74 x 47 x 33

4

1

(15.8)

74 x 47 x 41

5

1

(15.0)

74 x 47 x 41

6

1

12.0

88 x 59 x 41

7.5

2

12.1

88 x 59 x 49

8.5

2

12.0

88 x 59 x 49

10

2

12.3

116 x 63 x 57

@ 47° F

Heating Capacity

(HSPF) COP

34,000

(8.00)

46,000

(8.10)

55,000

(8.20)

70,000

3.40

84,000

3.50

100,000

3.40

116,000

3.50

@ 17° F

Heating Capacity

(HSPF) COP

18,400

(N/A)

23,800

(N/A)

28,600

(N/A)

39,000

2.40

47,000

2.40

56,000

2.26

65,000

2.40

Approx. Unit Weight (lbs.)
495 580 610 710 875 1020 1390

®
THE PROS KNOW
PO Box 128 Lewisburg, TN 37091
KeepRite.com
RGS/RAS/RHS/RGH/RAH/RHH Series © 2012 International Comfort Products, LLC

All systems tested and listed by the appropriate agencies.
As part of its commitment to quality, International Comfort Products, LLC, reserves the right to change specifications on its products without notice. Illustrations and photographs in this brochure are only representative. Some product models may vary.
Part No. 401-39-1320-00 Printed 09/12


Adobe PDF Library 9.9 Adobe InDesign CS5.5 (7.5.3)

Search Any Device: