Bekijk de CE-markering

Braytron ADVANCE- Led Bulb Lichtbron - LED Lamp - E27 Fitting - 12W - A60-4000K Wit licht | bol.com

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 14 Pages, 196.68KB

Document DEVICE REPORToriginal
BST Testing(Shenzhen)Co., Ltd.

Report No.: BSTXD211221069003SR

BRAYTRON S.R.L

Prepared For : Product Name:

LVD REPORT
BRAYTRON S.R.L
B.DUL IULIU MANIU, NR.616, CORP B, ETAJ 1 SECTOR 6, 061129,BUCHAREST,ROMANIA
LED BULB

Trade Name:

BRAYTRON

Main Test Model: BA13-25023

Additional Model: See Annex B

Prepared By : Test Date:

BST Testing (Shenzhen)Co., Ltd
No.7, New Era Industrial Zone, Guantian, Bao'an District, Shenzhen, Guangdong, China
Dec.23, 2021­Dec.30, 2021

Date of Report:

Dec.30, 2021

Report No.:

BSTXD211221069003SR

Add: Add: No.7,New Era Industrial Zone, Guantian, Bao'an District, Shenzhen, Guangdong, China Certificate Search: http://www.bst-lab.com, Tel: 400-962-6168, E-mail:[email protected]

Page 1 of 14

BST Testing(Shenzhen)Co., Ltd.

Report No.: BSTXD211221069001SR

TEST REPORT

EN 62560

Self-ballasted LED-lamps for general lighting services by voltage > 50 V ­ Safety specifications

Testing Laboratory Name ..................:BST Testing(Shenzhen)Co., Ltd

Address ................................................ :GNou.a7n,gNdeowngE, rCahInindaustrial Zone, Guantian, Bao'an District, Shenzhen,

Testing location............................:

BST Testing(Shenzhen)Co., Ltd

Applicant's Name ................................ :BRAYTRON S.R.L

Address ................................................ :B06.D1U12L9I,UBLUICUHMAARNEISUT, ,NRRO.6M1A6N, ICAORP B, ETAJ 1 SECTOR 6,

Manufacturer ............ ...............: DEMGRUP INTERNATIONAL LIGHTING LIMITED

Address .................. ...............:

UNIT D 16/F, ONE CAPITAL PLACE, 18 LUARD ROAD, WAN CHAI, HONG KONG

Test specification

N/A

Standard................................................:EN 62560:2012/A11:2019

Procedure deviation ........................... :N/A

Non-standard test method .................:N/A

Test item description .......................... :See page 1 Trade Name..........................................:See page 1 Model and/or type reference .............:See page 1 Rating(s)................................................:See label Test case verdicts: Test case does not apply to the test object ... : N(/A) Test item does meet the requirement ............. : P(ass) Test item does not meet the requirement ...... : F(ail)

Add: Add: No.7,New Era Industrial Zone, Guantian, Bao'an District, Shenzhen, Guangdong, China Certificate Search: http://www.bst-lab.com, Tel: 400-962-6168, E-mail:[email protected]

Page 2 of 14

BST Testing(Shenzhen)Co., Ltd.

Report No.: BSTXD211221069003SR

General remarks: This report shall not be reproduced except in full without the written approval of the testing laboratory. The test results presented in this report relate only to the item(s) tested. "(see remark #)" refers to a remark appended to the report. "(see Annex #)" refers to an annex appended to the report.
General product information: The series products have the same LED modules. The differences are the Luminaires model name and power, so, we select BA13-25023 to test. Artwork of Marking Label:

Prepared by : Reviewer : Approved & Authorized Signer :

Engineer Supervisor Manager

Add: Add: No.7,New Era Industrial Zone, Guantian, Bao'an District, Shenzhen, Guangdong, China Certificate Search: http://www.bst-lab.com, Tel: 400-962-6168, E-mail:[email protected]

Page 3 of 14

Clause 4 4.1 4.2
4.3 4.4 5 5.1
5.2
5.3

BST Testing(Shenzhen)Co., Ltd.

Report No.: BSTXD211221069003SR

Requirement + Test

EN 62560

Result - Remark

Verdict

General requirements and general test requirements

P

The lamps shall be so designed and constructed

P

that in normal use they function reliably and cause

no danger to the user or surroundings.

Self-ballasted LED-lamps are non-repairable,

P

factory-sealed units. They shall normally not be

opened for any tests. In the case of doubt based on

the inspection of the lamp and the examination of

the circuit diagram, and in agreement with the

manufacturer or responsible vendor, either the

output terminals shall be short-circuited or, in

agreement with the manufacturer, lamps specially

prepared so that a fault condition can be simulated

shall be submitted for testing (see Clause 13).

all tests are carried out on each type of lamp or,

P

where a range of similar lamps is involved, for each

wattage in the range or on a representative

selection from the range, as agreed with the

manufacturer.

When the lamp fails safely during one of the tests, it

P

is replaced, provided that no fire, smoke or

flammable gas is produced. Further requirements

on failing safe are given in Clause 12.

Marking

P

Lamps shall be clearly and durably marked with the

P

following mandatory markings:

a) mark of origin (this may take the form of a

see page 3

P

trademark, the manufacturer's name or the name of

the responsible vendor);

b) rated voltage or voltage range (marked "V" or

220-240V~

P

"volts");

c) rated wattage (marked "W" or "watts");

P

d) rated frequency (marked in "Hz").

50/60Hz

P

Addition marking

P

- rated current (A).......................................................... :

P

- weight significantly higher

N

- special conditions or restrictions

P

Not suitable for dimming;

symbol

P

used

- not suitable for water contact

N

Marking durable and legible

P

Add: Add: No.7,New Era Industrial Zone, Guantian, Bao'an District, Shenzhen, Guangdong, China Certificate Search: http://www.bst-lab.com, Tel: 400-962-6168, E-mail:[email protected]

Page 4 of 14

BST Testing(Shenzhen)Co., Ltd.

Report No.: BSTXD211221069001SR

rubbing 15 s water, 15 s petroleum; marking legible

P

6

INTERCHANGEABILITY

P

6.1

Cap interchangeability in accordance with IEC 60061-1

P

Gauge in accordance with IEC 60061-3

P

6.2

Bending moment and mass imparted by the lamp at the lampholder

P

Bending moment imparted by the lamp at the

2Nm

P

lampholder (Nm).......................................................... :

Mass not exceeding value table 2 or as specified in

P

IEC 60061-1 (kg)...........................................................:

7
8 8.1 8.2 8.3 9 9.1 9.2 9.2.1
9.3 9.4

Protection against accidental contact with live parts

P

Internal, basic insulated or live metal parts not

P

accessible

Tested with a test finger with a force of 10 N

P

Compliance checked with appropriate gauges

P

Insulation resistance and electric strength after humidity treatment

P

General

P

Insulation resistance

P

Electric strength

P

Mechanical strength

P

Lamps shall be able to withstand the relevant mechanical strength tests as given in

P

9.2.

Torsion resistance of unused lamps

P

Torque test

P

B15d or E14 Cap............................................ 1,15 Nm

N

B22d, E26, E26d or GX53 Cap.......................3,0 Nm

P

E11 or E12 Cap.................................................0,8 Nm

N

E17 Cap.............................................................1,5 Nm

N

E39 or E40 Cap.................................................5,0 Nm

N

GX53 Cap..........................................................3,0 Nm

N

Compliance criteria

P

Clause 8 shall comply after the mechanical

P

strength test.

Axial strength of Edison caps

P

After full insertion into the gauge an axial force of 120N

P

Table 4 is applied to the central contact (N)............:

Add: Add: No.7,New Era Industrial Zone, Guantian, Bao'an District, Shenzhen, Guangdong, China Certificate Search: http://www.bst-lab.com, Tel: 400-962-6168, E-mail:[email protected]

Page 5 of 14

BST Testing(Shenzhen)Co., Ltd.

Report No.: BSTXD211221069001SR

The insulation around the central contact shall

P

remain intact

10

Cap temperature rise

P

The cap temperature rise ts of the lamp shall not 60.5K, limit 120K

P

exceed 120 K.

11

Resistance to heat.

P

Parts of insulating material providing protection

P

against electric shock, retaining live parts in

position, ball-pressure test:

12

Resistance to flame and ignition

P

External parts of insulating material preventing

P

electric shock glow-wire test 650 C

13

Fault conditions

P

13.2

Fault conditions: where diagram indicates fault

P

condition impairs safety, electronic components

have been short-circuited or disconnected

13.3

When operated under fault conditions the lamp

P

- does not emit flames or molten material

P

- does not produce flammable gases or smoke

P

- live parts not accessible

P

After the tests the insulation resistance with d.c.

P

1000 V complies with requirements of Cl. 8.1 :

14

Creepage distances and clearances

P

Creepage distances and clearances according to Cr.>5.0mm, Cl. >5.0mm

P

IEC 61347-1

Conductive accessible parts according to IEC

P

60598-1

15

Abnormal operation

P

Non-dimmable self-ballasted lamps are tested on a

P

dimmer or an electronic switch according the test

circuit shown in Figure 8

Operate the lamp for 8 h at most onerous dimming

P

level

When operated under abnormal operation the lamp

P

- does not catch fire

P

- does not produce flammable gases

P

- live parts not accessible

P

Add: Add: No.7,New Era Industrial Zone, Guantian, Bao'an District, Shenzhen, Guangdong, China Certificate Search: http://www.bst-lab.com, Tel: 400-962-6168, E-mail:[email protected]

Page 6 of 14

16
17 17.1 17.2
17.3
18 18.1 18.2

BST Testing(Shenzhen)Co., Ltd.

Report No.: BSTXD211221069001SR

Test conditions for dimmable lamps

N

Test are carried out at maximum power setting for

N

Clause 10 and Clause 17

Photobiological safety

P

UV radiation

P

The ultraviolet hazard efficacy of luminous radiation

P

of an LED lamp shall not exceed 2 mW/klm.

Blue light hazard

P

The blue light hazard shall be assessed according RG0

P

to IEC TR 62778, which shall be regarded as

normative when testing LED lamps to this standard.

LED lamps shall be classified as risk group 0

unlimited or risk group 1 unlimited.

Infrared radiation

P

LED lamps are not expected to reach a level of

P

infrared radiation where marking or other safety

measurements are required.

INGRESS PROTECTION

N

Lamps shall be suitable for water contact unless

N

marked with Figure 6

The lamp is subjected to an IPX4 test according to

N

IEC 60598-1

The lamp complies with the compliance provisions

N

of 9.2 of IEC 60598-1

Lamps constructed so that it is sealed to exclude

N

water need not to be tested

Add: Add: No.7,New Era Industrial Zone, Guantian, Bao'an District, Shenzhen, Guangdong, China Certificate Search: http://www.bst-lab.com, Tel: 400-962-6168, E-mail:[email protected]

Page 7 of 14

BST Testing(Shenzhen)Co., Ltd.

Report No.: BSTXD211221069001SR

ANNEX 1

Components

Object / part Manufacture

No.

r/trademark

Type / model Technical data

Internal wiring (input) Internal wiring (input)
Connector
Connector
Connector

TONGXIANG CITY LI'AO CABLE CO LTD
TONGXIAN G ZHOUQUA NHONGKE ELECTRIC FACTORY
XIAMEN GHGM INDUSTRIAL TRADE CO LTD
PUTIAN HANJIAN G FUCON ELECTRONIC S CO LTD
WENZHOU JKUN CONNECTO RCO LTD

1007

80;300V

1007

80;300V

GL2C002SFR 130;V-0

CM-20281-02P CM-2028-202P
CM-2027

130;V-0

A2002AWR- 130;V-0 02

Connector

DONGGUAN SOLEPIN ELECTRONIC SCO LTD

100802MSN01

130;V-0

Fuse resister

SHENZHEN GREAT ELECTRONIC SCO LTD

RXF-1W Series

2W/10R

Fuse resister Fuse resister

HUAIAN LINGJIE TECHNOLOG Y DEVELOPIN G CO LTD
CHANGZHO U WUJIN HUAYU ELECTRONIC SCO LTD

Type RF10 Series
RXF1WS

2W/10R 2W/10R

Standard
IEC 62560:2011 , AMD1:2015
IEC 62560:2011 , AMD1:2015
IEC 62560:2011 , AMD1:2015
IEC 62560:2011, AMD1:2015
IEC 62560:2011 , AMD1:2015
IEC 62560:2011 , AMD1:2015
IEC 62560:2011 , AMD1:2015
IEC 62560:2011 , AMD1:2015
IEC 62560:2011 , AMD1:2015

P Mark(s) of conformity1) Tested with appliance UL/ E479070
Tested with appliance UL/ E365749
Tested with appliance UL/ E360430
Tested with appliance UL/ E467583
Tested with appliance UL/ E473017
Tested with appliance UL/ E506639
Tested with appliance UL/ E301541
Tested with appliance UL/ E249662
Tested with appliance UL/ E479825

Add: Add: No.7,New Era Industrial Zone, Guantian, Bao'an District, Shenzhen, Guangdong, China Certificate Search: http://www.bst-lab.com, Tel: 400-962-6168, E-mail:[email protected]

Page 8 of 14

BST Testing(Shenzhen)Co., Ltd.

Report No.: BSTXD211221069001SR

Heat shrinkable sleeve Heat shrinkable sleeve Heat shrinkable sleeve Varistor
Varistor
Enclosure
Enclosure
LED
LED
PCB of LED module

SHENZHEN WOER HEATSHRINKABL E MATERIAL COLTD

RSFR-H

600V;VW-1;125 

DONGGUAN SALIPT CO LTD
SHENZHEN WOLIDA TRADING COLTD

SALIPT S901-600
RSFR-H

600V;VW-1;125 
600V;VW-1;125 

Hongzhi Enterprises

HEL10D511K RMS300V

Ltd.

Shantou High-

New

Technology 10D511K

RMS300V

Dev. Zone

Songtian

Enterprise Co.,

Ltd.

NANTONG ORIENT PLASTICS COLTD

3080 G(zz) V-0;130

JINYOUNG (XIAMEN) ADVANCED MATERIALS TECHNOLOG YCO LTD

TG30WX

V-0;130

Bridgelux COLTD

2835

9V 100mA

Seoul Semiconduct orCo LTD

2835

JIANGXI TIANYI CIRCUITS SCIENCE AND TECHNOLOG Y CO LTD

TY-003

9V 100mA
0,21mm;130 V-0

IEC 62560:2011 , AMD1:2015

Tested with appliance UL/ E203950

IEC 62560:2011 , AMD1:2015

Tested with appliance UL/ E209436

IEC 62560:2011 , AMD1:2015

Tested with appliance UL/ E329530

IEC/EN 61051- VDE 40037512 1

IEC/EN 61051- VDE 40023049 1

IEC 62560:2011 , AMD1:2015

Tested with appliance UL/ E332375

IEC 62560:2011 , AMD1:2015
IEC 62560:2011 , AMD1:2015
IEC 62560:2011 , AMD1:2015
IEC 62560:2011 , AMD1:2015

Tested with appliance UL/ E475922
Tested withappliance
Tested withappliance
Tested with appliance UL/ E496359

Add: Add: No.7,New Era Industrial Zone, Guantian, Bao'an District, Shenzhen, Guangdong, China Certificate Search: http://www.bst-lab.com, Tel: 400-962-6168, E-mail:[email protected]

Page 9 of 14

BST Testing(Shenzhen)Co., Ltd.

Report No.: BSTXD211221069001SR

PCB of LED module

JINGDEZHE N HONGYI ELECTRONIC SCO LTD

PCB of LED module
PCB of LED module

Hubei ZhongPei Electronics Technology Co.,Ltd
QUZHOU TIANYING ELECTRONIC SCO LTD

PCB of LED module

LONGXING ELECTRONIC MATERIALS COLTD

LED cover

MITSUBISHI ENGINEERIN G-PLASTICS CORP

LED cover

NANTONG ORIENT PLASTICS COLTD

Plastic on the KINGFA SCI Lamp cap &TECH CO
LTD

HY-1 ZP-2

0,18mm;130 V-0
0,28mm;130 V-0

TY-F02 LX-L

0,2mm;130 V0
V-0130

S-2000+(f1) V-2;80

HYB-PCR-G1 GWFI 650

PBTRG301(r1 )

V-0;125

IEC 62560:2011 , AMD1:2015
IEC 62560:2011 , AMD1:2015
IEC 62560:2011 , AMD1:2015
IEC 62560:2011 , AMD1:2015
IEC 62560:2011 , AMD1:2015
IEC 62560:2011 , AMD1:2015
IEC 62560:2011 , AMD1:2015

Tested with appliance UL/ E348413
Tested with appliance UL/ E481795
Tested with appliance UL/ E482814
Tested with appliance UL/ E500854
Tested withappliance UL/ E41179
Tested withappliance
Tested withappliance

Annex 2

(normative) Lamps with operating position limitations (see 5.2)

N

Add: Add: No.7,New Era Industrial Zone, Guantian, Bao'an District, Shenzhen, Guangdong, China Certificate Search: http://www.bst-lab.com, Tel: 400-962-6168, E-mail:[email protected]

Page 10 of 14

BST Testing(Shenzhen)Co., Ltd.

Report No.: BSTXD211221069001SR

Table 8.2 Test comments

Title: Insulating resistance

Location

Between

And

L

N

Live parts

Enclosure

P Insulation resistance (M)
>100M >100M

Table 8.3 Test comments

Title: Electric strength

Location

Between

And

Live parts Live parts

Enclosure Mounting surface

Test voltage
3000V 3000V

Table 11
Test comments

Parts Enclosure

Title: Ball pressure

Test temp. () 75

Impression diameter (mm) 0.92

P
Breakdown
No No
Results P
Limits (mm) 2

Table 12 Test comments

Parts Shade Enclosure

Title: Glow wire test Test temp. () 650 650

P
Results
Any flame or glowing extinguish within 30s
Any flame or glowing extinguish within 30s

Table 13 Part C1 Output

Simulated fault Short-circuit Short-circuit

TABLE: tests of fault conditions Test voltage 242V 242V

P Hazard No No

Add: Add: No.7,New Era Industrial Zone, Guantian, Bao'an District, Shenzhen, Guangdong, China Certificate Search: http://www.bst-lab.com, Tel: 400-962-6168, E-mail:[email protected]

Page 11 of 14

BST Testing(Shenzhen)Co., Ltd.

Report No.: BSTXD211221069001SR

ANNEX A:
Photo-documentation

Add: Add: No.7,New Era Industrial Zone, Guantian, Bao'an District, Shenzhen, Guangdong, China Certificate Search: http://www.bst-lab.com, Tel: 400-962-6168, E-mail:[email protected]

Page 12 of 14

BST Testing(Shenzhen)Co., Ltd.

Report No.: BSTXD211221069001SR

EUT

EUT

Add: Add: No.7,New Era Industrial Zone, Guantian, Bao'an District, Shenzhen, Guangdong, China Certificate Search: http://www.bst-lab.com, Tel: 400-962-6168, E-mail:[email protected]

Page 13 of 14

BST Testing(Shenzhen)Co., Ltd.

Report No.: BSTXD211221069001SR

Annex B
Additional Model : BA05-X03XX, BA05-X04XX, BA05-X05XX, BA05-X06XX, BA05-X07XX, BA05-X08XX, BA06-X03XX, BA06-X04XX, BA06-X05XX, BA06-X06XX, BA06-X07XX, BA06-X08XX, BA07-X03XX, BA07-X04XX, BA07-X05XX, BA07-X06XX, BA07-X07XX, BA07-X08XX, BA08-X03XX, BA08-X04XX, BA08-X05XX, BA08-X06XX, BA08-X07XX, BA08-X08XX, BA09-X03XX, BA09-X04XX, BA09-X05XX, BA09-X06XX, BA09-X07XX, BA09-X08XX, BA10-X03XX, BA10-X04XX, BA10-X05XX, BA10-X06XX, BA10-X07XX, BA10-X08XX, BA11-X03XX, BA11-X04XX, BA11-X05XX, BA11-X06XX, BA11-X07XX, BA11-X08XX, BA12-X05XX, BA12-X06XX, BA12-X07XX, BA12-X08XX, BA12-X09XX, BA12-X10XX, BA12-X11XX, BA12-X12XX, BA12-X13XX, BA12-X14XX, BA12-X15XX, BA12-X16XX, BA12-X17XX, BA12-X18XX, BA13-X05XX, BA13-X06XX, BA13-X07XX, BA13-X08XX, BA13-X09XX, BA13-X10XX, BA13-X11XX, BA13-X12XX, BA13-X13XX, BA13-X14XX, BA13-X15XX, BA13-X16XX, BA13-X17XX, BA13-X18XX, BA13-X20XX, BA13-X24XX, BA13-X25XX, BA13-X28XX, BA13-X30XX, BA13-X35XX, BA13-X38XX, BA13-X40XX, BA13-X45XX, BA13-X48XX, BA13-X50XX, BA13-X60XX, BA14-X05XX, BA14-X06XX, BA14-X07XX, BA14-X08XX, BA14-X09XX, BA14-X10XX, BA14-X11XX, BA14-X12XX, BA14-X13XX, BA14-X14XX, BA14-X15XX, BA14-X16XX, BA14-X17XX, BA14-X18XX, BA14-X20XX, BA14-X24XX, BA14-X25XX, BA14-X28XX, BA14-X30XX, BA14-X35XX, BA14-X38XX, BA14-X40XX, BA14-X45XX, BA14-X48XX, BA14-X50XX, BA14-X60XX, BA15-X05XX, BA15-X06XX, BA15-X07XX, BA15-X08XX, BA15-X09XX, BA15-X10XX, BA15-X11XX, BA15-X12XX, BA15-X13XX, BA15-X14XX, BA15-X15XX, BA15-X16XX, BA15-X17XX, BA15-X18XX, BA15-X20XX, BA15-X24XX, BA15-X25XX, BA15-X28XX, BA15-X30XX, BA15-X35XX, BA15-X38XX, BA15-X40XX, BA15-X45XX, BA15-X48XX, BA15-X50XX, BA15-X60XX, BA16-X05XX, BA16-X06XX, BA16-X07XX, BA16-X08XX, BA16-X09XX, BA16-X10XX, BA16-X11XX, BA16-X12XX, BA16-X13XX, BA16-X14XX, BA16-X15XX, BA16-X16XX, BA16-X17XX, BA16-X18XX, BA16-X20XX, BA16-X24XX, BA16-X25XX, BA16-X28XX, BA16-X30XX, BA16-X35XX, BA16-X38XX, BA16-X40XX, BA16-X45XX, BA16-X48XX, BA16-X50XX, BA16-X60XX, BA17-X03XX, BA17-X04XX, BA17-X05XX, BA17-X06XX, BA17-X07XX, BA17-X08XX, BA17-X09XX, BA17-X10XX, BA17-X11XX, BA17-X12XX, BA17-X13XX, BA17-X14XX, BA17-X15XX, BA17-X16XX, BA17-X17XX, BA17-X18XX, BA22-X03XX, BA22-X04XX, BA22-X05XX, BA22-X06XX, BA22-X07XX, BA22-X08XX, BA23-X03XX, BA23-X04XX, BA23-X05XX, BA23-X06XX, BA23-X07XX, BA23-X08XX, BA24-X03XX, BA24-X04XX, BA24-X05XX, BA24-X06XX, BA24-X07XX, BA24-X08XX, BA25-X03XX, BA25-X04XX, BA25-X05XX, BA25-X06XX, BA25-X07XX, BA25-X08XX, BA26-X03XX, BA26-X04XX, BA26-X05XX, BA26-X06XX, BA26-X07XX, BA26-X08XX, BA27-X03XX, BA27-X04XX, BA27-X05XX, BA27-X06XX, BA27-X07XX, BA27-X08XX, BA28-X03XX, BA28-X04XX, BA28-X05XX, BA28-X06XX, BA28-X07XX, BA28-X08XX, BA29-X02XX, BA29-X03XX, BA29-X04XX, BA29-X05XX, BA29-X06XX, BA29-X07XX, BA29-X08XX, BA30-X02XX, BA30-X03XX, BA30-X04XX, BA30-X05XX, BA30-X06XX, BA30-X07XX, BA30-X08XX, BA30-X09XX, BA30-X10XX, BA30-X11XX, BA30-X12XX, BA33-X10XX, BA33-X11XX, BA33-X12XX, BA33-X13XX, BA33-X14XX, BA33-X15XX, BA34-X05XX, BA34-X06XX, BA34-X07XX, BA34-X08XX, BA34-X09XX, BA34-X10XX, BA34-X11XX, BA34-X12XX, BA34-X13XX, BA34-X14XX, LC-0505, LC-0607 (X=0,1,2,3,4,5,6,7,8,9)

Add: Add: No.7,New Era Industrial Zone, Guantian, Bao'an District, Shenzhen, Guangdong, China Certificate Search: http://www.bst-lab.com, Tel: 400-962-6168, E-mail:[email protected]

Page 14 of 14



References

GPL Ghostscript 9.26

Search Any Device: