TestRpt Part 96.47

Fibocom Wireless Inc. FM350GL 5G Module ZMOFM350GL ZMOFM350GL fm350gl

FM350GL Rpt CBSD

LC Future Center TP00128B Notebook Computer 2AJN7-TP00128B 2AJN7TP00128B tp00128b

LC Future Center TP00129B Notebook Computer 2AJN7-TP00129B 2AJN7TP00129B tp00129b

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 10 Pages, 496.49KB

Document DEVICE REPORTGetApplicationAttachment.html?id=5660769
FCC RADIO TEST REPORT

Report No. : FG0D1540

FCC Part 96.47 TEST REPORT

FCC ID Equipment Brand Name Model Name Applicant
Manufacturer
Standard

: ZMOFM350GL
: 5G Module : Fibocom
: FM350-GL
: Fibocom Wireless Inc. 1101, Tower A, Building 6, Shenzhen International Innovation Valley, Dashi 1st Rd, Nanshan, Shenzhen, China.
: Fibocom Wireless Inc. 1101, Tower A, Building 6, Shenzhen International Innovation Valley, Dashi 1st Rd, Nanshan, Shenzhen, China.
: FCC Part 96.47

The product was received on Feb. 19, 2021 and testing was started from Feb. 23, 2021 and completed on Feb. 23, 2021. We, SPORTON INTERNATIONAL INC. EMC & Wireless Communications Laboratory, would like to declare that the tested sample has been evaluated in accordance with the test procedures and has been in compliance with the applicable technical standards.
The test results in this report apply exclusively to the tested model / sample. Without written approval of SPORTON INTERTIONAL INC. EMC & Wireless Communications Laboratory, the test report shall not be reproduced except in full.

Approved by: Sam Chen

SPORTON INTERTIONAL INC. EMC & Wireless Communications Laboratory
No. 52, Huaya 1st Rd., Guishan Dist., Taoyuan City, Taiwan (R.O.C.)

TEL : 886-3-327-3456 FAX : 886-3-328-4978 Report Template No.: BU5-FGLTE96.47 Version 2.0

Page Number Issued Date Report Version

: 1 of 10 : Mar. 02, 2021 : 01

FCC RADIO TEST REPORT

Report No. : FG0D1540

Table of Contents
History of this test report.................................................................................................................................3 Summary of Test Result...................................................................................................................................4 1 General Description ................................................................................................................................... 5
1.1 Product Feature of Equipment Under Test........................................................................................5 1.2 Modification of EUT ........................................................................................................................... 5 1.3 Testing Location ................................................................................................................................ 5 1.4 Applicable Standards.........................................................................................................................5 2 Test Configuration of Equipment Under Test ......................................................................................... 6 2.1 Connection Diagram of Test System ................................................................................................. 6 3 End User Device additional requirement ................................................................................................. 7 3.1 Test Requirement .............................................................................................................................. 7 3.2 Test Procedure .................................................................................................................................. 7 3.3 Test Result.........................................................................................................................................8 4 List of Measuring Equipment..................................................................................................................10 Appendix A Test Setup Photographs

TEL : 886-3-327-3456 FAX : 886-3-328-4978 Report Template No.: BU5-FGLTE96.47 Version 2.0

Page Number Issued Date Report Version

: 2 of 10 : Mar. 02, 2021 : 01

FCC RADIO TEST REPORT

Report No. : FG0D1540

History of this test report

Report No. FG0D1540

Version 01

Description Initial issue of report

Issued Date Mar. 02, 2021

TEL : 886-3-327-3456 FAX : 886-3-328-4978 Report Template No.: BU5-FGLTE96.47 Version 2.0

Page Number Issued Date Report Version

: 3 of 10 : Mar. 02, 2021 : 01

FCC RADIO TEST REPORT

Report No. : FG0D1540

Summary of Test Result

Report Clause

Ref Std. Clause

3

96.47

Test Items

Result (PASS/FAIL)

End User Device additional requirement

Pass

Remark -

Declaration of Conformity: The test results with all measurement uncertainty excluded are presented in accordance with the regulation limits or requirements declared by manufacturers. Comments and Explanations: The declared of product specification for EUT presented in the report are provided by the manufacturer, and the manufacturer takes all the responsibilities for the accuracy of product specification.
Reviewed by: Louis Wu Report Producer: Dara Chiu

TEL : 886-3-327-3456 FAX : 886-3-328-4978 Report Template No.: BU5-FGLTE96.47 Version 2.0

Page Number Issued Date Report Version

: 4 of 10 : Mar. 02, 2021 : 01

FCC RADIO TEST REPORT

Report No. : FG0D1540

1 General Description
1.1 Product Feature of Equipment Under Test

WCDMA/LTE/5G NR and GNSS

Product Specification subjective to this standard

Antenna Type

WWAN: PIFA Antenna BDS/Galileo/GLONASS/GPS: Ceramics Antenna

Remark: The above EUT's information was declared by manufacturer. Please refer to Comments and

Explanations in report summary.

1.2 Modification of EUT
No modifications are made to the EUT during all test items.

1.3 Testing Location

Test Site Test Site Location
Test Site No. Test Engineer Temperature

SPORTON INTERNATIONAL INC. EMC & Wireless Communications Laboratory No.52, Huaya 1st Rd., Guishan Dist., Taoyuan City, Taiwan (R.O.C.) TEL: +886-3-327-3456 FAX: +886-3-328-4978
Sporton Site No. DFS02-HY
Thomas Chen 21 ~ 25 

Relative Humidity

50 ~ 56 %

Note: The test site complies with ANSI C63.4 2014 requirement.

FCC Designation No.: TW1190

1.4 Applicable Standards
 FCC Part 96.47  FCC KDB 940660 D01 Part 96 CBRS Eqpt v03  WINNF-TS-0122-V1.0.2 CBRS CBSD Test Specification
Remark: All test items were verified and recorded according to the standards and without any deviation during the test.

TEL : 886-3-327-3456 FAX : 886-3-328-4978 Report Template No.: BU5-FGLTE96.47 Version 2.0

Page Number Issued Date Report Version

: 5 of 10 : Mar. 02, 2021 : 01

FCC RADIO TEST REPORT

Report No. : FG0D1540

2 Test Configuration of Equipment Under Test
2.1 Connection Diagram of Test System

The companion device is certified CBRS (FCC ID: S9GQ710US02)

TEL : 886-3-327-3456 FAX : 886-3-328-4978 Report Template No.: BU5-FGLTE96.47 Version 2.0

Page Number Issued Date Report Version

: 6 of 10 : Mar. 02, 2021 : 01

FCC RADIO TEST REPORT

Report No. : FG0D1540

3 End User Device additional requirement
3.1 Test Requirement

FCC Part 96.47 (a) End User Devices may operate only if they can positively receive and decode an authorization signal transmitted by a CBSD, including the frequencies and power limits for their operation. (1) An End User Device must discontinue operations, change frequencies, or change its operational power level within 10 seconds of receiving instructions from its associated CBSD.

3.2 Test Procedure
Following procedure can be done by applying WINNF-TS-0122-V1.0.2 CBRS CBSD Test Specification, use the certified Ruckus CBSD (FCC ID: S9GQ710US02) as companion device to show compliance with Part 96.47 requirement for End User Device (EUD):
1. Setup with frequency 3600-3620MHz and power level 7dBm/MHz 2. Enable AP service from Ruckus Cloud management 3. Check EUD Tx Frequency and power 4. Disable AP service from Ruckus Cloud management
a. Check EUD stops transmission within 10seconds.
5. Setup with 3670-3690MHz & power level 17dBm/MHz 6. Enable AP service from Ruckus Cloud management 7. Check EUD Tx Frequency and power 8. Disable AP service from Ruckus Cloud management
a. Check EUD stops transmission within 10seconds.

TEL : 886-3-327-3456 FAX : 886-3-328-4978 Report Template No.: BU5-FGLTE96.47 Version 2.0

Page Number Issued Date Report Version

: 7 of 10 : Mar. 02, 2021 : 01

FCC RADIO TEST REPORT

Report No. : FG0D1540

3.3 Test Result
[Step 1] Setup with frequency 3600-3620MHz and power level 7dBm/MHz [Step 3] Check EUD Tx Frequency and power

[Step 4.a.] EUD stops transmission within 10 seconds of receiving instructions from its associated CBSD.

TEL : 886-3-327-3456 FAX : 886-3-328-4978 Report Template No.: BU5-FGLTE96.47 Version 2.0

Page Number Issued Date Report Version

: 8 of 10 : Mar. 02, 2021 : 01

FCC RADIO TEST REPORT

Report No. : FG0D1540

[Step 5] Setup with 3670-3690MHz & power level 17dBm/MHz [Step 7] Check EUD Tx Frequency and power

[Step 8.a.] After changing the frequency and power level, The module (EUT) discontinues operations, change frequencies, or change its operational power level within
10 seconds of receiving instructions from its associated CBSD. Test result is PASS.

TEL : 886-3-327-3456 FAX : 886-3-328-4978 Report Template No.: BU5-FGLTE96.47 Version 2.0

Page Number Issued Date Report Version

: 9 of 10 : Mar. 02, 2021 : 01

FCC RADIO TEST REPORT

Report No. : FG0D1540

4 List of Measuring Equipment

Instrument Manufacturer Model No.

Spectrum Analyzer

Rohde & Schwarz

FSV3044

Calibration Serial No. Characteristics
Date

Test Date

Due Date

Remark

101048 10Hz~44GHz Apr. 29, 2020 Feb. 23, 2021 Apr. 28, 2021 DFS02-HY

TEL : 886-3-327-3456 FAX : 886-3-328-4978 Report Template No.: BU5-FGLTE96.47 Version 2.0

Page Number Issued Date Report Version

: 10 of 10 : Mar. 02, 2021 : 01



Related FCC IDs:

Search Any Device: