Report No.: 220730738EMC-1

TEST REPORT

Product Name: Trade Mark:
Model No. / HVIN: Report Number: Test Standards:
FCC ID: IC:
Test Result: Date of Issue:

Module CINTERION PLS63-W-B 220730738EMC-1 FCC 47 CFR Part 15 Subpart B ICES-003 Issue 7 QIPPLS63-W-B 7830A-PLS63WB PASS November 10, 2022

Prepared for:

Thales DIS AIS Deutschland GmbH Siemensdamm 50, 13629 Berlin, Germany

Prepared by:
Shenzhen UnionTrust Quality and Technology Co., Ltd. Unit D/E of 9/F and 16/F, Block A, Building 6, Baoneng science and
technology park, Longhua district, Shenzhen, China TEL: +86-755-2823 0888 FAX: +86-755-2823 0886

Prepared by:

Kieron Luo Project Engineer

Reviewed by:

Henry Lu Team Leader

Approved by:

Kevin Liang Assistant Manager

Date:

November 10, 2022

Shenzhen UnionTrust Quality and Technology Co., Ltd.

Address: Unit D/E of 9/F and 16/F, Block A, Building 6, Baoneng science and technology park, Longhua district, Shenzhen, China

Tel: +86-755-28230888

Fax: +86-755-28230886

E-mail: [email protected]

http://www.uttlab.com

UTTR-EMC-ICES003-V1.2

Version
Version No. V1.0

Page 2 of 20
Date November 10, 2022

Report No.: 220730738EMC-1
Description Original

Shenzhen UnionTrust Quality and Technology Co., Ltd.

Address: Unit D/E of 9/F and 16/F, Block A, Building 6, Baoneng science and technology park, Longhua district, Shenzhen, China

Tel: +86-755-28230888

Fax: +86-755-28230886

E-mail: [email protected]

http://www.uttlab.com

UTTR-EMC-ICES003-V1.2

Page 3 of 20

Report No.: 220730738EMC-1

CONTENTS
1. GENERAL INFORMATION .......................................................................................................................................4
1.1 CLIENT INFORMATION ........................................................................................................................................4 1.2 EUT INFORMATION ............................................................................................................................................4
1.2.1 GENERAL DESCRIPTION OF EUT ............................................................................................................4 1.2.2 DESCRIPTION OF ACCESSORIES..............................................................................................................4 1.3 DESCRIPTION OF SUPPORT UNITS ......................................................................................................................4 1.4 TEST LOCATION.................................................................................................................................................5 1.5 TEST FACILITY...................................................................................................................................................5 1.6 DEVIATION FROM STANDARDS ............................................................................................................................5 1.7 ABNORMALITIES FROM STANDARD CONDITIONS..................................................................................................5 1.8 OTHER INFORMATION REQUESTED BY THE CUSTOMER ........................................................................................5 1.9 MEASUREMENT UNCERTAINTY ...........................................................................................................................6
2. TEST SUMMARY ......................................................................................................................................................7 3. EQUIPMENT LIST ....................................................................................................................................................8 4. TEST CONFIGURATION ..........................................................................................................................................9
4.1 ENVIRONMENTAL CONDITIONS FOR TESTING........................................................................................................9 4.1.1 NORMAL OR EXTREME TEST CONDITIONS ...............................................................................................9 4.1.2 RECORD OF NORMAL ENVIRONMENT.......................................................................................................9
4.2 TEST MODES.....................................................................................................................................................9 4.3 TEST SETUP ......................................................................................................................................................9
4.3.1 FOR RADIATED EMISSIONS TEST SETUP ..................................................................................................9 4.3.2 FOR CONDUCTED EMISSIONS TEST SETUP ............................................................................................10 4.4 SYSTEM TEST CONFIGURATION ........................................................................................................................10
5. REFERENCE DOCUMENTS FOR TESTING......................................................................................................... 11 6. EMC REQUIREMENTS SPECIFICATION .............................................................................................................. 11
6.1 RADIATED EMISSION........................................................................................................................................ 11 6.2 CONDUCTED EMISSION ....................................................................................................................................17
APPENDIX 1 PHOTOS OF TEST SETUP .....................................................................................................................20 APPENDIX 2 PHOTOS OF EUT CONSTRUCTIONAL DETAILS .................................................................................20

Shenzhen UnionTrust Quality and Technology Co., Ltd.

Address: Unit D/E of 9/F and 16/F, Block A, Building 6, Baoneng science and technology park, Longhua district, Shenzhen, China

Tel: +86-755-28230888

Fax: +86-755-28230886

E-mail: [email protected]

http://www.uttlab.com

UTTR-EMC-ICES003-V1.2

Page 4 of 20

Report No.: 220730738EMC-1

1. GENERAL INFORMATION

1.1 CLIENT INFORMATION

Applicant:

Thales DIS AIS Deutschland GmbH

Address of Applicant:

Siemensdamm 50, 13629 Berlin, Germany

Manufacturer:

Thales DIS AIS Deutschland GmbH

Address of Manufacturer: Werinherstr.81, 81541 Munich, Germany

1.2 EUT INFORMATION
1.2.1 General Description of EUT

Product Name:

Module

Model No.:

PLS63-W-B

Trade Mark: DUT Stage:

CINTERION Production Unit

Rated Voltage:

 DC3.8V provide from adaptor 120V~60Hz

Classification of digital devices: Highest Internal Frequency: Original Sample Received Date: Original Sample Tested Date:
Sample Received Date:

Class B 2.6 GHz July 24, 2020 August 10, 2020 to August 20, 2020 December 3, 2020

Sample Tested Date:

December 18, 2020 to December 18, 2020

EUT identification

200722014-A01/2

Note:

This product PLS63-W-B include two SIM types: SIM and ESIM

1.2.2 Description of Accessories
None.

1.3 DESCRIPTION OF SUPPORT UNITS

The EUT has been tested with associated equipment below. 1) Support Equipment

Description

Manufacturer

Model No.

Adaptor

N/A

CD139

PCB board

N/A

DSB75

PCB board

N/A

AH8

50 ohm terminal

N/A

N/A

Serial Number 20359 --N/A

Supplied by Applicant Applicant Applicant UnionTrust

2) Support Cable Cable No. --

Description --

Connector --

Length --

Supplied by --

Shenzhen UnionTrust Quality and Technology Co., Ltd.

Address: Unit D/E of 9/F and 16/F, Block A, Building 6, Baoneng science and technology park, Longhua district, Shenzhen, China

Tel: +86-755-28230888

Fax: +86-755-28230886

E-mail: [email protected]

http://www.uttlab.com

UTTR-EMC-ICES003-V1.2

1.4 TEST LOCATION

Page 5 of 20

Report No.: 220730738EMC-1

Shenzhen UnionTrust Quality and Technology Co., Ltd.
Address: Unit D/E of 9/F and 16/F, Block A, Building 6, Baoneng science and technology park, Longhua district, Shenzhen, China 518109 Telephone: +86 (0) 755 2823 0888 Fax: +86 (0) 755 2823 0886

1.5 TEST FACILITY

The test facility is recognized, certified, or accredited by the following organizations:
CNAS-Lab Code: L9069 The measuring equipment utilized to perform the tests documented in this report has been calibrated once a year or in accordance with the manufacturer's recommendations, and is traceable under the ISO/IEC 17025 to international or national standards. Equipment has been calibrated by accredited calibration laboratories.
A2LA-Lab Certificate No.: 4312.01 Shenzhen UnionTrust Quality and Technology Co., Ltd. has been accredited by A2LA for technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025 General Requirements for the Competence of Testing and Calibration Laboratories and any additional program requirements in the identified field of testing.
ISED Wireless Device Testing Laboratories CAB identifier: CN0032
FCC Accredited Lab. Designation Number: CN1194 Test Firm Registration Number: 259480

1.6 DEVIATION FROM STANDARDS
None.
1.7 ABNORMALITIES FROM STANDARD CONDITIONS
None.
1.8 OTHER INFORMATION REQUESTED BY THE CUSTOMER
None.

Shenzhen UnionTrust Quality and Technology Co., Ltd.

Address: Unit D/E of 9/F and 16/F, Block A, Building 6, Baoneng science and technology park, Longhua district, Shenzhen, China

Tel: +86-755-28230888

Fax: +86-755-28230886

E-mail: [email protected]

http://www.uttlab.com

UTTR-EMC-ICES003-V1.2

Page 6 of 20

Report No.: 220730738EMC-1

1.9 MEASUREMENT UNCERTAINTY

Where relevant, the following measurement uncertainty levels have been estimated for tests performed on the Product as specified in CISPR 16-4-2. This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.

No.

Item

Measurement Uncertainty

1

Conducted emission 9KHz-150KHz

±3.2 dB

2

Conducted emission 150KHz-30MHz

±2.7 dB

3

Radiated emission 9KHz-30MHz

± 4.7 dB

4

Radiated emission 30MHz-1GHz

± 4.6 dB

5

Radiated emission 1GHz-18GHz

± 4.4 dB

6

Radiated emission 18GHz-26GHz

± 4.6 dB

7

Radiated emission 26GHz-40GHz

± 4.6 dB

Shenzhen UnionTrust Quality and Technology Co., Ltd.

Address: Unit D/E of 9/F and 16/F, Block A, Building 6, Baoneng science and technology park, Longhua district, Shenzhen, China

Tel: +86-755-28230888

Fax: +86-755-28230886

E-mail: [email protected]

http://www.uttlab.com

UTTR-EMC-ICES003-V1.2

Page 7 of 20

Report No.: 220730738EMC-1

2. TEST SUMMARY

FCC 47 CFR Part 15 Subpart B Test Cases

Test Item

Test Requirement

Test Method

Result

Conducted Emission
Radiated Emission Note:

FCC 47 CFR Part 15.107 ICES-003 Issue 7 Section
3.2.1
FCC 47 CFR Part 15.109 ICES-003 Issue 7 Section
3.2.2

ANSI C63.4-2014 ANSI C63.4-2014

Pass
(SEE NOTE 1)
Pass
(SEE NOTE 1)

1) This report is based on the previous report that changed the software version and ICES-003 standard version. The main change is that the module only supports data services. Please refer to declaration of difference for more details. After the evaluation, all technical data is referred to previous report no. 200722016EMC-1 dated February 3, 2021.

Test Plan: 1) According to the difference description, PLS63-W-B shares the same data from the PLS63-W original report
(Report No.: 200722016EMC-1). 2) The difference is defined by the applicant and the referenced data complies with FCC/ISED regulationsand
the applicant assumes full responsibility. 3) The data of PLS63-W-B was used for PLS63-W as bellow

Test Item Conducted Emission Radiated Emission

Description Reuse Reuse

Shenzhen UnionTrust Quality and Technology Co., Ltd.

Address: Unit D/E of 9/F and 16/F, Block A, Building 6, Baoneng science and technology park, Longhua district, Shenzhen, China

Tel: +86-755-28230888

Fax: +86-755-28230886

E-mail: [email protected]

http://www.uttlab.com

UTTR-EMC-ICES003-V1.2

Page 8 of 20

Report No.: 220730738EMC-1

3. EQUIPMENT LIST

Used 

Equipment
3M Chamber & Accessory Equipment



Receiver



Broadband Antenna



6dB Attenuator



Preamplifier



Horn Antenna (Pre-amplifier)



Multi device Controller



Test Software

Radiated Emission Test Equipment List

Manufacturer Model No.

Serial Number

Cal. date (mm dd, yyyy)

Cal. Due date (mm dd, yyyy)

ETS-LINDGREN

3M

N/A

Dec. 03, 2018 Dec. 03, 2021

R&S

ESIB26

100114

ETS-LINDGREN 3142E

00201566

Talent

RA6A5-N18

18103001

HP

8447F

2805A02960

ETS-LINDGREN 3117-PA

00201874

Nov. 24, 2019 Nov. 18, 2020 Nov. 16, 2019 Nov. 14, 2020 Nov. 16, 2019 Nov. 14, 2020 Nov. 16, 2019 Nov. 10, 2020 Nov. 16, 2019 May 30, 2020

Nov. 23, 2020 Nov. 17, 2021 Nov. 15, 2020 Nov. 13, 2021 Nov. 15, 2020 Nov. 13, 2021 Nov. 15, 2020 Nov. 9, 2021 Nov. 15, 2020 May 29, 2021

ETS-LINDGREN 7006-001

00160105

N/A

N/A

Audix

e3

Software Version: 9.160323

Used
    

Equipment
Receiver Pulse Limiter
LISN LISN Test Software

Conducted Emission Test Equipment List

Manufacturer R&S

Model No. ESR7

Serial Number
1316.3003K07 -101181-K3

R&S

ESH3-Z2 0357.8810.54

Cal. date (mm dd, yyyy) Nov. 24, 2019
Nov. 24, 2019

Cal. Due date (mm dd, yyyy) Nov. 23, 2020
Nov. 23, 2020

R&S

ESH2-Z5 860014/024 Nov. 24, 2019 Nov. 23, 2020

ETS-Lindgren 3816/2SH

00201088

Nov. 24, 2019 Nov. 23, 2020

Audix

e3

Software Version: 9.160323

Shenzhen UnionTrust Quality and Technology Co., Ltd.

Address: Unit D/E of 9/F and 16/F, Block A, Building 6, Baoneng science and technology park, Longhua district, Shenzhen, China

Tel: +86-755-28230888

Fax: +86-755-28230886

E-mail: [email protected]

http://www.uttlab.com

UTTR-EMC-ICES003-V1.2

Page 9 of 20

Report No.: 220730738EMC-1

4. TEST CONFIGURATION

4.1 ENVIRONMENTAL CONDITIONS FOR TESTING

4.1.1 Normal or Extreme Test Conditions

Environment Parameter

Selected Values During Tests

Test Condition

Temperature (°C)

Ambient Voltage (V)

Relative Humidity (%)

NT/NV

+15 to +35

3.8

20 to 75

Remark: 1) NV: Normal Voltage; NT: Normal Temperature

4.1.2 Record of Normal Environment

Test Item

Temperature (°C)

Conducted Emission

24.8

Radiated Emission

25.3

Relative Humidity (%) 70
56

Pressure (kPa) 99.40
100.92

Tested by
Tripp Jiang Andy Lin

4.2 TEST MODES

Test Item

EMI Test Modes

Radiated Emission Conducted Emission

Mode 1: Charging from adapter + GSM850+ GPS on Mode 2: Charging from adapter + WCDMA II+ GPS on Mode 3: Charging from adapter + LTE B7+ GPS on Mode 4: ESIM select worst mode from mode1~3
Mode 1: Charging from adapter + GSM850+ GPS on Mode 2: Charging from adapter + WCDMA II+ GPS on Mode 3: Charging from adapter + LTE B7+ GPS on Mode 4: ESIM select worst mode from mode1~3

Remark: The above test modes in boldface were the worst cases, only the test data of these modes were reported.

4.3 TEST SETUP
4.3.1 For Radiated Emissions test setup
Figure 1. 30MHz to 1GHz

Shenzhen UnionTrust Quality and Technology Co., Ltd.

Address: Unit D/E of 9/F and 16/F, Block A, Building 6, Baoneng science and technology park, Longhua district, Shenzhen, China

Tel: +86-755-28230888

Fax: +86-755-28230886

E-mail: [email protected]

http://www.uttlab.com

UTTR-EMC-ICES003-V1.2

Page 10 of 20
Figure 2. Above 1GHz

Report No.: 220730738EMC-1

4.3.2 For Conducted Emissions test setup
Figure 3. Conducted Emissions setup

4.4 SYSTEM TEST CONFIGURATION
All readings are extrapolated back to the equivalent three meter reading using inverse scaling with distance. Analyzer resolution is 100 kHz or greater for frequencies below 1000MHz. The resolution is 1 MHz or greater for frequencies above 1000MHz. The spurious emissions more than 20 dB below the permissible value are not reported. Radiated emission measurement were performed from the lowest radio frequency signal generated in the device which is greater than 9 kHz to the tenth harmonic (according to KDB 896810 D02 SDoC FAQ v01r01) of the highest fundamental frequency or to 40 GHz, whichever is lower.

Shenzhen UnionTrust Quality and Technology Co., Ltd.

Address: Unit D/E of 9/F and 16/F, Block A, Building 6, Baoneng science and technology park, Longhua district, Shenzhen, China

Tel: +86-755-28230888

Fax: +86-755-28230886

E-mail: [email protected]

http://www.uttlab.com

UTTR-EMC-ICES003-V1.2

Page 11 of 20

Report No.: 220730738EMC-1

5. REFERENCE DOCUMENTS FOR TESTING

No.

Identity

Document Title

1 FCC 47 CFR Part15 Subpart B Unintentional Radiators

American National Standard for Methods of Measurement of

2

ANSI C63.4-2014

Radio-Noise Emissions from Low-Voltage Electrical and Electronic

Equipment in the Range of 9 kHz to 40 GHz

3

KDB 174176 D01 Line Conducted FAQ v01r01

AC power-line conducted emission frequency asked questions

4

KDB 896810 D02 SDoC FAQ v01r02

Supplier's Declaration of Conformity frequency asked questions

5

ICES-003 Issue 7

Information Technology Equipment (Including Digital Apparatus)

6. EMC REQUIREMENTS SPECIFICATION

6.1 RADIATED EMISSION

Test Requirement: FCC 47 CFR Part 15.109, ICES-003 Issue 7 Clause 3.2.2

Test Method:

ANSI C63.4-2014

Receiver Setup:

Frequency: (f) (MHz)

Detector type

Measurement receiver bandwidth

RBW

VBW

30  f  1 000

Quasi Peak

120 kHz

300 kHz

f 1000

Peak Average

1 MHz 1 MHz

3 MHz 3 MHz

Measured frequency range

Highest frequency generated or used in the device or on which the device operates or tunes
(MHz)

Upper frequency of measurement range (MHz)

Below 1.705

30.

1.705-108

1000.

108-500

2000.

500-1000

5000.

Above 1000

5th harmonic of the highest frequency or 40 GHz, whichever is lower.

Limits:
Limits for Class B devices FCC 47 CFR Part 15 Subpart B

Frequency (MHz)

QP Detector

limits at 3m (dBV/m) PK Detector

AV Detector

30 ­ 88

40.0

--

--

88 ­ 216

43.5

--

--

216 ­ 960

46.0

960 ­ 1000

54.0

--

--

Above 1000

--

74.0

54.0

ICES-003 Issue 7

Frequency (MHz)

QP Detector

limits at 3m (dBV/m) PK Detector

AV Detector

30 ­ 88

40.0

--

--

88 ­ 216

43.5

--

--

216 ­ 230

46.0

230 ­ 960

47.0

--

--

Shenzhen UnionTrust Quality and Technology Co., Ltd.

Address: Unit D/E of 9/F and 16/F, Block A, Building 6, Baoneng science and technology park, Longhua district, Shenzhen, China

Tel: +86-755-28230888

Fax: +86-755-28230886

E-mail: [email protected]

http://www.uttlab.com

UTTR-EMC-ICES003-V1.2

Page 12 of 20

Report No.: 220730738EMC-1

960 ­ 1000 Above 1000

54.0

--

--

--

74.0

54.0

Remark:

1. The lower limit shall apply at the transition frequencies.

2. Emission level (dBV/m) = 20 log Emission level (V/m).

3. For frequencies above 1000 MHz, the field strength limits are based on average detector, however, the

peak field strength of any emission shall not exceed the maximum permitted average limits, specified above

by more than 20 dB under any condition of modulation.

Test Setup:

Refer to section 4.3.1 for details.

Test Procedures:

1. From 30 MHz to 1GHz test procedure as below:

1) The Product was placed on the non-conductive turntable 0.8 m above the ground at a chamber. 2) Set the spectrum analyzer/receiver in Peak detector, Max Hold mode, and 120 kHz RBW. Record the
maximum field strength of all the pre-scan process in the full band when the antenna is varied between 1~4 m in both horizontal and vertical, and the turntable is rotated from 0 to 360 degrees. 3) For each frequency whose maximum record was higher or close to limit, measure its QP value: vary the antenna's height and rotate the turntable from 0 to 360 degrees to find the height and degree where Product radiated the maximum emission, then set the test frequency analyzer/receiver to QP Detector and specified bandwidth with Maximum Hold Mode, and record the maximum value.

2. Above 1GHz test procedure as below:

1) The Product was placed on the non-conductive turntable 0.8 m above the ground at a chamber. 2) Set the spectrum analyzer/receiver in Peak detector, Max Hold mode, and 1MHz RBW. Record the
maximum field strength of all the pre-scan process in the full band when the antenna is varied in both horizontal and vertical, and the turntable is rotated from 0 to 360 degrees. 3) For each frequency whose maximum record was higher or close to limit, measure its AV value: rotate the turntable from 0 to 360 degrees to find the degree where Product radiated the maximum emission, then set the test frequency analyzer/receiver to AV value and specified bandwidth with Maximum Hold Mode, and record the maximum value.

Equipment Used: Refer to section 3 for details.

Test Result:

Pass

The measurement data as follows:

Shenzhen UnionTrust Quality and Technology Co., Ltd.

Address: Unit D/E of 9/F and 16/F, Block A, Building 6, Baoneng science and technology park, Longhua district, Shenzhen, China

Tel: +86-755-28230888

Fax: +86-755-28230886

E-mail: [email protected]

http://www.uttlab.com

UTTR-EMC-ICES003-V1.2

Below 1GHz(Quasi Peak): Mode2 Horizontal

Page 13 of 20

Report No.: 220730738EMC-1

No.

Frequency (MHz)

Reading (dBV)

Correction factor (dB/m )

Result (dBV/m)

Limit (dBV/m)

Margin (dB)

Detector

1

34.045

23.70

-4.80

18.90

40.00

-21.10

QP

2

47.703

32.40

-13.14

19.26

40.00

-20.74

QP

3

101.893

29.93

-15.88

14.05

43.50

-29.45

QP

4

176.275

24.86

-10.45

14.41

43.50

-29.09

QP

5

728.897

24.36

1.63

25.99

46.00

-20.01

QP

6

881.184

25.13

3.92

29.05

46.00

-16.95

QP

Shenzhen UnionTrust Quality and Technology Co., Ltd.

Address: Unit D/E of 9/F and 16/F, Block A, Building 6, Baoneng science and technology park, Longhua district, Shenzhen, China

Tel: +86-755-28230888

Fax: +86-755-28230886

E-mail: [email protected]

http://www.uttlab.com

UTTR-EMC-ICES003-V1.2

Vertical

Page 14 of 20

Report No.: 220730738EMC-1

No.

Frequency (MHz)

Reading (dBV)

Correction factor (dB/m )

Result (dBV/m)

Limit (dBV/m)

Margin (dB)

Detector

1

32.411

29.93

-4.85

25.08

40.00

-14.92

QP

2

41.448

34.96

-8.88

26.08

40.00

-13.92

QP

3

55.288

46.72

-17.14

29.58

40.00

-10.42

QP

4

125.806

35.19

-15.80

19.39

43.50

-24.11

QP

5

177.518

29.45

-10.22

19.23

43.50

-24.27

QP

6

893.656

24.29

4.23

28.52

46.00

-17.48

QP

Shenzhen UnionTrust Quality and Technology Co., Ltd.

Address: Unit D/E of 9/F and 16/F, Block A, Building 6, Baoneng science and technology park, Longhua district, Shenzhen, China

Tel: +86-755-28230888

Fax: +86-755-28230886

E-mail: [email protected]

http://www.uttlab.com

UTTR-EMC-ICES003-V1.2

Above 1GHz(Peak & Average) Mode2 Horizontal

Page 15 of 20

Report No.: 220730738EMC-1

No.

Frequency (MHz)

Reading (dBV)

Correction factor (dB/m )

Result (dBV/m)

Limit (dBV/m)

Margin (dB)

Detector

1

1246.212

48.75

-11.27

37.48

74.00

-36.52

Peak

2

3702.714

44.57

-4.60

39.97

74.00

-34.03

Peak

3

5521.982

43.58

-0.57

43.01

74.00

-30.99

Peak

4

7207.945

44.28

1.24

45.52

74.00

-28.48

Peak

5

11065.320

42.02

6.58

48.60

74.00

-25.40

Peak

6

16031.010 39.97

11.36

51.33

74.00

-22.67

Peak

Shenzhen UnionTrust Quality and Technology Co., Ltd.

Address: Unit D/E of 9/F and 16/F, Block A, Building 6, Baoneng science and technology park, Longhua district, Shenzhen, China

Tel: +86-755-28230888

Fax: +86-755-28230886

E-mail: [email protected]

http://www.uttlab.com

UTTR-EMC-ICES003-V1.2

Vertical

Page 16 of 20

Report No.: 220730738EMC-1

No.

Frequency (MHz)

Reading (dBV)

Correction factor (dB/m )

Result (dBV/m)

Limit (dBV/m)

Margin (dB)

Detector

1

1109.891

49.06

-11.03

38.03

74.00

-35.97

Peak

2

2954.015

47.46

-7.69

39.77

74.00

-34.23

Peak

3

5521.982

44.29

-0.08

44.21

74.00

-29.79

Peak

4

7291.932

45.29

1.35

46.64

74.00

-27.36

Peak

5

11930.720 42.19

7.39

49.58

74.00

-24.42

Peak

6

17587.750 39.19

13.22

52.41

74.00

-21.59

Peak

Remark:
1. Correct Factor = Antenna Factor + Cable Loss - Amplifier Gain, the value was added to Original Receiver Reading by the software automatically.
2. Result = Reading + Correct Factor. 3. Margin = Result ­ Limit 4. As shown in this section, for frequencies above 1GHz, the field strength limits are based on average limits.
However, the peak field strength of any emission shall not exceed the maximum permitted average limits specified above by more than 20 dB under any condition of modulation. So, only the peak measurements were shown in the report. 5. The limit of ICES-003 in the 230MHz to 960MHz band is higher than that of FCC Part 15B, so the radiation emission test data conform to the limit of ICES-003.

Shenzhen UnionTrust Quality and Technology Co., Ltd.

Address: Unit D/E of 9/F and 16/F, Block A, Building 6, Baoneng science and technology park, Longhua district, Shenzhen, China

Tel: +86-755-28230888

Fax: +86-755-28230886

E-mail: [email protected]

http://www.uttlab.com

UTTR-EMC-ICES003-V1.2

Page 17 of 20

Report No.: 220730738EMC-1

6.2 CONDUCTED EMISSION

Test Requirement: FCC 47 CFR Part 15.107, ICES-003 Issue 7 Section 3.2.1

Test Method:

ANSI C63.4-2014

Limits:

Limits for Class B devices

Frequency range (MHz)

Quasi-peak

Limits (dB(V)

Average

0,15 to 0,50

66 to 56

56 to 46

0,50 to 5

56

46

5 to 30

60

50

Remark:

1. The lower limit shall apply at the transition frequencies.

2. The limit decreases linearly with the logarithm of the frequency in the range 0.15 to 0.50 MHz.

Test Setup:

Refer to section 4.3.2 for details.

Test Procedures:

1) The Product was placed on a nonconductive table 0.8 m above the horizontal ground reference plane, and 0.4 m from the vertical ground reference plane, and connected to the main through Line Impedance Stability Network (L.I.S.N).
2) The RBW of the receiver was set at 9 kHz in 150 kHz ~ 30MHz with Peak and AVG detector in Max Hold mode. Run the receiver's pre-scan to record the maximum disturbance generated from Product in all power lines in the full band.
3) For each frequency whose maximum record was higher or close to limit, measure its QP and AVG values and record.

Equipment Used: Refer to section 3 for details.

Test Result:

Pass

Shenzhen UnionTrust Quality and Technology Co., Ltd.

Address: Unit D/E of 9/F and 16/F, Block A, Building 6, Baoneng science and technology park, Longhua district, Shenzhen, China

Tel: +86-755-28230888

Fax: +86-755-28230886

E-mail: [email protected]

http://www.uttlab.com

UTTR-EMC-ICES003-V1.2

The measurement data as follows: Quasi Peak and Average: Mode 3
Live Line

Page 18 of 20

Report No.: 220730738EMC-1

No.

Frequency (MHz)

1

0.430

2

0.430

3

0.634

4

0.634

5

5.910

6

5.910

Reading (dBV)
23.98 40.37 15.15 30.41 8.78 24.70

Correction factor (dB ) 9.22 9.22 9.34 9.34 9.64 9.64

Result (dBV)
33.20 49.59 24.49 39.75 18.42 34.34

Limit (dBV)
47.25 57.25 46.00 56.00 50.00 60.00

Margin (dB)
-14.05 -7.66 -21.51 -16.25 -31.58 -25.66

Detector
Average QP
Average QP
Average QP

Shenzhen UnionTrust Quality and Technology Co., Ltd.

Address: Unit D/E of 9/F and 16/F, Block A, Building 6, Baoneng science and technology park, Longhua district, Shenzhen, China

Tel: +86-755-28230888

Fax: +86-755-28230886

E-mail: [email protected]

http://www.uttlab.com

UTTR-EMC-ICES003-V1.2

Neutral Line

Page 19 of 20

Report No.: 220730738EMC-1

No.

Frequency (MHz)

1

0.430

2

0.430

3

0.670

4

0.670

5

13.557

6

13.557

Reading (dBV)
18.02 34.97 6.64 24.69 5.51 24.21

Correction factor (dB ) 9.22 9.22 9.38 9.38 9.81 9.81

Result (dBV)
27.24 44.19 16.02 34.07 15.32 34.02

Limit (dBV)
47.25 57.25 46.00 56.00 50.00 60.00

Margin (dB)
-20.01 -13.06 -29.98 -21.93 -34.68 -25.98

Detector
Average QP
Average QP
Average QP

Remark:
1. Correct Factor = LISN Factor + Cable Loss + Pulse Limiter Factor, the value was added to Original Receiver Reading by the software automatically.
2. Result = Reading + Correct Factor. 3. Margin = Result - Limit 4. An initial pre-scan was performed on the Phase and neutral lines with peak detector. Quasi-Peak and
Average measurement were performed at the frequencies with maximized peak emission were detected.

Shenzhen UnionTrust Quality and Technology Co., Ltd.

Address: Unit D/E of 9/F and 16/F, Block A, Building 6, Baoneng science and technology park, Longhua district, Shenzhen, China

Tel: +86-755-28230888

Fax: +86-755-28230886

E-mail: [email protected]

http://www.uttlab.com

UTTR-EMC-ICES003-V1.2

Page 20 of 20
APPENDIX 1 PHOTOS OF TEST SETUP

Report No.: 220730738EMC-1

See test photos attached in Appendix 1 for the actual connections between Product and support equipment.

APPENDIX 2 PHOTOS OF EUT CONSTRUCTIONAL DETAILS

Refer to Appendix 2 for EUT external and internal photos.

********************* End of Report *********************
The test report is effective only with both signature and specialized stamp. The result(s) shown in this report refer only to the sample(s) tested. Without written approval of UnionTrust, this report can't be reproduced except in full.

Shenzhen UnionTrust Quality and Technology Co., Ltd.

Address: Unit D/E of 9/F and 16/F, Block A, Building 6, Baoneng science and technology park, Longhua district, Shenzhen, China

Tel: +86-755-28230888

Fax: +86-755-28230886

E-mail: [email protected]

http://www.uttlab.com

UTTR-EMC-ICES003-V1.2



Related FCC IDs:

Search Any Device: