TR3768 166 BTC FHSS

Adam Hauke

Test Report DSS

Ezurio LLC SONANX611M Wi-Fi 6/BT Transceiver radio SQG-SONANX611M SQGSONANX611M sonanx611m

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 36 Pages, 5.74MB

Document DEVICE REPORTGetApplicationAttachment.html?id=7712496
A

Test Report TR3768-166-BTC-FHSS

Equipment Under Test: Module, SONA NX 611 M.2 2230, 1 MHF

Requirement(s):

eCFR 47 Part 15.247 | RSS-247

Test Date(s):

01/22/2024-04/30/2024

Prepared for:

Ezurio Attn: Brian Petted W66 N220 Commerce Ct. Cedarburg, WI 53012

Report Issued by: Adam Hauke, EMC Engineer Signature:
Report Reviewed by: Adam Alger, Manager EMC Laboratory Signature:
Report Constructed by: Adam Hauke, EMC Engineer Signature:

Date: 08/08/2024 Date: 8/08/2024 Date: 08/07/2024

This test report may not be reproduced, except in full, without approval of Ezurio

Company: Ezurio Report: TR3768-166-BTC-FHSS Job: C-3768

Page 1 of 36

Name: Module, SONA NX611 M.2, 1 MHF Model: SONA NX611M Serial: 00047

CONTENTS
Contents........................................................................................................................................................ 2 Ezurio Test Services in Review .................................................................................................................. 3
1 Test Report Summary ........................................................................................................................... 4 2 Client Information................................................................................................................................. 5
2.1 Equipment Under Test (EUT) Information................................................................................... 5 2.2 Product Description..................................................................................................................... 5 2.3 Modifications Incorporated for Compliance ............................................................................... 5 2.4 Deviations and Exclusions from Test Specifications.................................................................... 5 2.5 EUT Information .......................................................................................................................... 5 2.6 Ancillary Equipment .................................................................................................................... 6 2.7 Antenna Information ................................................................................................................... 6 2.8 Test Channels............................................................................................................................... 6 2.9 Power Table and Reduced Video Bandwidth for Average Measurements ................................. 6 3 Worst Case Test Results Summary........................................................................................................ 7 4 References ............................................................................................................................................ 8 5 Uncertainty Summary ........................................................................................................................... 9 6 Test Data ............................................................................................................................................. 10 6.1 Antenna Port Conducted Emissions .......................................................................................... 10 6.2 Radiated Emissions .................................................................................................................... 27 6.3 AC Mains Conducted Emissions................................................................................................. 33 7 Revision History .................................................................................................................................. 36

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 2 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

Ezurio Test Services in Review The Ezurio laboratory located at W66 N220 Commerce Court Cedarburg, Wisconsin, 53012 USA is recognized through the following organizations:
A2LA ­ American Association for Laboratory Accreditation Accreditation based on ISO/IEC 17025:2017 with Electrical (EMC) Scope A2LA Certificate Number: 1255.01 Scope of accreditation includes all test methods listed herein unless otherwise noted

Federal Communications Commission (FCC) ­ USA Accredited Test Firm Registration Number: 953492 Recognition of two 3 meter Semi-Anechoic Chambers

Innovation, Science and Economic Development Canada Accredited U.S. Identification Number: US0218 Recognition of two 3 meter Semi-Anechoic Chambers

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 3 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

1 TEST REPORT SUMMARY
During 01/22/2024-04/30/2024 the Equipment Under Test (EUT), Module, SONA NX611 M.2 2230, 1 MHF, as provided by Ezurio was tested to the following requirements:

FCC 15.247 | RSS-247 ­ FHSS Bluetooth Classic

Requirements

Description

15.247(d) 15.209 RSS-247 Clause 5.5 RSS-GEN Clause 8.10
2.1049 RSS-247 Clause 6.6

Spurious Radiated Emissions in Restricted Bands 30-40000 MHz
Occupied Bandwidth and 20dB DTS BW

15.247(b)(1) RSS-247 Clause 5.4 (b)
15.247(d) RSS-247 Clause 5.5 RSS-GEN A1 Clause 8.9
15.247(a)(1) RSS-247 Clause 5.1
2.1055(d) RSS-GEN 6.11

RF Output Power
Out-of-band Emissions
Channel Separation, Number of Hopping Frequencies, and Time of Occupancy Frequency Stability

15.207 RSS-GEN 8.8

AC Conducted Emissions

Method ANSI C63.10
ANSI C63.10 ANSI C63.10 ANSI C63.10 ANSI C63.10 ANSI C63.10 ANSI C63.10

Compliant Yes
Yes Yes Yes Yes Reported Yes

Notice:
The results relate only to the item tested as configured and described in this report. Any additional configurations, modes of operation, or modifications made to the equipment under test after the specified test date(s) are at the decision of the client and may not apply to the data seen in this test report.
The decision rule for Pass / Fail assessment to the specification or standard listed in this test report has been agreed upon by the client and laboratory to be as follows:

Measurement Type Emissions ­ Amplitude Emissions ­ Frequency Immunity

Rule 0.1 dB below specified limit 1% less than the specification
Tested at specified level

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 4 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

2 CLIENT INFORMATION

Company Name

Ezurio

Contact Person

Brain Petted

Address

W66 N220 Commerce Ct. Cedarburg, WI 53012

2.1 Equipment Under Test (EUT) Information The following information has been supplied by the client

Product Name

Module, SONA NX611 M.2 2230, 1 MHF

Part Number

453-00166

Serial Number

00047

FCC ID

SQG-SONANX611M

IC ID

3147A-SONANX611M

2.2 Product Description
The NX611 is based upon NXP IW611 Wi-Fi 6 chipset. Feature-set includes 802.11 a/b/g/n/ac/ax Wi-Fi 6 and Dual-Mode Bluetooth v5.3 (BDR + EDR + BLE).

2.3 Modifications Incorporated for Compliance None noted at time of test

2.4 Deviations and Exclusions from Test Specifications None noted at time of test

2.5 EUT Information

Power Supply ­ INPUT:100-240VAC 50/60 Hz 0.3A OUTPUT: 5VDC 2A

Firmware -

sduart_nw61x_v1.bin.se

Sduart_nw61x_v1_mfg.bin.se

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 5 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

2.6 Ancillary Equipment

Equipment used for EUT programming (not part of the EUT)

Development Kit, SU60-SOMC 6.0

P/N:

463-00138-K1 Rev 1

Power Supply: INPUT:

100-240 VAC 50/60Hz 0.7A

HP Elitebook 840G1

OUTPUT:

12VDC 2A

Labtool

Version: 1.0.0.45.6

2.7 Antenna Information

Peak Gain (dBi)

Manufacturer Model Part Number Dimension

Type 2400-2500 4900-5925

MHz MHz

Laird Connectivity

FlexMIMO EFD2471A3S- 39.5mm X 39.5mm

6E

10MH4L

X 4.7mm

PIFA

2.2

3.8

Laird Connectivity

FlexPIFA 6E

EFB2471A3S10MH4L

16mm X 36mm X 2.5mm

PIFA

2.2

3.9

Mini

Laid Connectivity NanoBlade

EMF2471A3S10MH4L

36mm X 12mm X 0.3mm

PCB Dipole

2.4

4.4

Flex 6E

Joymax Electronics

N/A TWX-100BRS3B 137mm X 13mm Dipole

2.0

4.0

Laird Connectivity

FlexPIFA

EFB2455A3S- 38.5mm X 12.7 mm

16MHF1

X 2.5mm

PIFA

2.5

3.0

2.8 Test Channels
Channel 0 39 78

Frequency (MHz) 2402 2441 2480

Data Rates DH5, 2DH5, and 3DH5

2.9 Power Table and Reduced Video Bandwidth for Average Measurements

Data Rate
DH5 2DH5 3DH5

Minimum Average VBW (Hz) 360 360 360

Power Setting
6 6 6

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 6 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

3 WORST CASE TEST RESULTS SUMMARY

Requirement

Channel and Data Rate

2.1049

RSS-247 Clause 6.6

39 | DH5

20 dB DTS Bandwidth

15.247 (b)(1)

RSS-247 Clause 5.4 (b) 39 | DH5

Output Power

15.247 (d)

RSS-247 Clause 5.5

78 | DH5

Conducted

15.247(d)

RSS-247 Clause 5.5 19 | Basic Rate

RSS-GEN Clause 8.9 Single Channel

Radiated

15.207 RSS-GEN 8.8

37 | 1DH5

Frequency (MHz)
2487.5
64.8 0.512

Measurement
956 kHz 7.0 dBm 59.8 dBµV/m 34.8 dBµV/m 24.2 dBµV

Limit
at least 500 kHz
30.0 dBm
74.0 dBµV/m
40.0 dBµV/m
46.0 dBµV

Margin
23.0 dB 14.2 dB 5.2 dB 21.8 dB

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 7 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

4 REFERENCES
Publication FCC eCFR 47 Part 15 ANSI C63.10 RSS-247 RSS-GEN KDB 558074 D01

Edition 3 5 -

Date 2023 2020 2023 2018 2019

AMD 1 -
2019 -

AMD 2 -
2021 -

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 8 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

5 UNCERTAINTY SUMMARY
Using the guidance of the following publications the calculated measurement uncertainty represents an expanded uncertainty expressed at approximately the 95 % confidence level, using a coverage factor of k = 2.
References CISPR 16-4-1 CISPR 16-4-2 CISPR 32 ANSI C63.23 A2LA P103 A2LA P103c ETSI TR 100-028

Measurement Type Radiated Emissions Radiated Emissions Radiated Emissions AC Line Conducted Emissions Telecom Conducted Emissions Disturbance Power Emissions Radiated Immunity Conducted Immunity EFT Burst/Surge ESD Immunity

Configuration Biconical Antenna Log Periodic Antenna
Horn Antenna Artificial Mains Network Asymmetric Artificial Network
Absorbing Clamp 3 Volts/meter CDN/EM/BCI
Peak pulse voltage 15 kV level

Uncertainty ± 5.0 dB 5.3 dB 4.7 dB 3.4 dB 4.9 dB 4.1 dB 2.2 dB
2.4/3.5/3.4 dB 164 volts 1377 Volts

Parameter Radio Frequency, from F0 Occupied Channel Bandwidth RF conducted Power (Power Meter) RF conducted emissions (Spectrum Analyzer) All emissions, radiated Temperature Humidity Supply voltages

ETSI U.C. ± 1x10-7 5 % 1.5 dB 3.0 dB 6.0 dB 1° C 5 % 3 %

U.C. ± 0.55x10-7
2 % 1.2 dB 1.7 dB 5.3 dB 0.65° C 2.9 %
1 %

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 9 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

6 TEST DATA

6.1 Antenna Port Conducted Emissions

Description of Measurement

The direct measurement of emissions at the antenna port of the EUT is achieved by use of a RF connection to a spectrum analyzer or power meter.
The cable and attenuator factors are loaded into the analyzer or power meter allowing for direct measurement readings without the need for further corrections.

Example Calculations

Measurement (dBm) + Cable factor (dB) + External Attenuator (dB) = Corrected Reading (dBm)
Margin (dB) = Limit (dBm) ­ Corrected Reading (dBm)

Block Diagram EUT

RF Cable

Ext. Atten
.

Spectrum Analyzer/
Power Meter

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 10 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

6.1.1 20dB DTS and 99% Occupied Bandwidth

Operator

Dylan Rosenfeldt

Temperature 22.3°C

Test Date 03/15/2024

Requirement

2.1049 RSS-247 Clause 6.6

QA R.H. % Location Method

Adam Hauke 30.30% Conducted RF Bench ANSI C63.10 6.9

Limits: Frequency hopping systems shall have hopping channel carrier frequencies separated by a minimum of 25 kHz or the 20 dB bandwidth of the hopping channel, whichever is greater.

Test Parameters Frequency 2400-2483.5 MHz

RBW

30 kHz

Detector(s) Peak

Setup VBW Settings

Antenna Port 300 kHz Max Hold

Instrumentation

Asset # AA 960173 EE 960085

Description
Cable
Analyzer - EMI Receiver

Manufacturer A.H. Systems,
Inc.
Agilent

Model # SAC-26G-1
N9038A

Serial # 388
MY51210148

Date 6/13/2023 4/27/2023

Due Date 6/12/2024 4/27/2024

Status Active Verification Active Calibration

EUT Parameters Input Power 120 VAC @ 60 Hz Frequency 2400-2483.5 MHz

Mode Channel

BTC FHSS Tx See 2.9

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 11 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

Table

Rate DH5 2DH5 3DH5

Channel 0 39 78 0 39 78 0 39 78

20 dB BW (kHz) 957 956 957 1333 1332 1338 1301 1302 1302

99% BW (kHz) 858 862 858 1180 1180 1179 1181 1183 1185

Plots

Channel 39 | DH5

Channel 78 | 2DH5

Channel 0 | 3DH5

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 12 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

6.1.2 RF Output Power

Operator

Dylan Rosenfeldt

Temperature 21.8°C

Test Date 03/12/2024

Requirement

15.247 (b)(1) RSS-247 Clause 5.4 (b)

QA R.H. % Location Method

Adam Hauke 32.20% Conducted RF Bench ANSI C63.10 11.9.1

Limit: For frequency hopping systems operating in the 2400-2483.5 MHz band employing at least 75 non-overlapping hopping channels: 1 watt.

Test Parameters Frequency 2400-2483.5 MHz

RBW

3 MHz

Detector(s) Peak

Setup VBW Settings

Antenna Port
50 MHz Max Hold Span: 10 MHz

Instrumentation

Asset # AA 960173 EE 960088

Description
Cable
Analyzer - EMI Receiver

Manufacturer A.H. Systems,
Inc.
Agilent

Model # SAC-26G-1
N9038A

Serial # 388
MY51210138

Date 6/13/2023 4/10/2023

Due Date 6/12/2024 4/10/2024

Status Active Verification Active Calibration

EUT Parameters Input Power 120 VAC @ 60 Hz Frequency 2400-2483.5 MHz

Mode Channel

BTC FHSS Tx See 2.9

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 13 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

Tables

Rate DH5 2DH5 3DH5

Channel 0 39 78 0 39 78 0 39 78

Peak Output Power (dBm) 6.7 7.0 7.0 5.0 4.9 4.7 5.3 5.1 4.9

Limit (dBm) 30 30 30 30 30 30 30 30 30

Margin (dB) 23.3 23.0 23.0 25.0 25.1 25.3 24.7 24.9 25.1

Plots

Channel 39 | DH5

Channel 0 | 2DH5

Channel 0 | 3DH5

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 14 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

6.1.3 Out-of-band Emissions

Operator

Dylan Rosenfeldt

Temperature 22.3°C | 21.9°C

Test Date 03/11/2024 | 03/29/2024

Requirement

15.247(d) RSS-247 Clause 5.5

QA R.H. % Location Method

Adam Alger 27.30% | 24.50% Conducted RF Bench ANSI C63.10 11.12.2.5.2

Limits: In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power, based on either an RF conducted or a radiated measurement provided the transmitter demonstrates compliance with the peak conducted power limits.

Reference Level (Worst Case PSD) DH5 ­ 6.8 dBm/100 kHz 6.8 dBm-20 dB = -13.2 dBm Limit

Test Parameters Frequency 30-40000 MHz

Setup

Antenna Port

RBW

100 kHz

VBW

300 kHz

Detector(s) Peak and Average (RMS)

Notes
Example Calculations

Declared antenna gain for band edge ­ 2.5 dBi Correction Factor = 20 log (1/D), where D is the duty cycle

Instrumentation

Asset # AA 960172 EE 960085 EE 960087 AA 960173

Description
Cable
Analyzer ­ Spectrum Analyzer Spectrum
Cable

Manufacturer A.H. Systems,
Inc.
Agilent
Agilent
A.H. Systems, Inc.

Model # SAC-26G-1
N9010A N9010A SAC-26G-1

Serial # 387
MY53400296 MY53400296
388

Date 06/13/2023 04/11/2023 4/11/2023 6/13/2023

Due Date 06/12/2024 04/11/2024 4/11/2024 6/12/2024

Status Active Verification Active Calibration Active Calibration Active Verification

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 15 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

Input Power 120 VAC @ 60 Hz Frequency 2400-2483.5 MHz

Mode Channel

BTC FHSS Tx See 2.8

Measurements

Rate DH5 2DH5 3DH5

Channel 0 78
Hopping Hopping
0 78 Hopping Hopping 0 78 Hopping Hopping

Frequency (MHz) 2399.9 2493.0 2390.6 2489.0 2399.9 2483.6 2399.6 2490.0 2400.0 2484.4 2399.9 2483.8

Measurement (dBm) -51.2 -49.3 -49.9 -50.1 -52.3 -57.4 -55.8 -58.1 -50.2 -55.3 -51.9 -56.8

Limit (dBm) -13.2 -13.2 -13.2 -13.2 -13.2 -13.2 -13.2 -13.2 -13.2 -13.2 -13.2 -13.2

Margin (dB) 38.0 36.1 36.7 36.9 39.1 44.2 42.6 44.9 37.0 42.1 38.7 43.6

Worst Case Plots

Channel 0 |DH5 | Reference

Channel 78 | DH5 | 2390-2400 MHz

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 16 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

Channel 0 | DH5 | 30-2390 MHz

Channel 78 | DH5 | 2490-25000 MHz

Channel 39 | 3DH5 | 25000-40000 MHz

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 17 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

6.1.4 Spurious Emissions in The Restricted Bands

Operator

Dylan Rosenfeldt

Temperature 22.3°C | 21.9°C

Test Date 03/11/2024 | 03/29/2024

Requirement

15.247(d) RSS-247 Clause 5.5

QA R.H. % Location Method

Adam Alger 27.30% | 24.50% Conducted RF Bench ANSI C63.10 11.12.2.5.2

15.209 Limits:
Frequency (MHz)
30-88 88-216 216-960 960-1000 1000-40000

Quasi-Peak Limit (dBµV/m) 40.0 43.5 46.0 54.0 -

Average Limit (dBµV/m) 54.0

Peak Limit (dBµV/m)
74.0

Test Parameters Frequency 30-40000 MHz

Setup

Antenna Port

RBW

100 kHz

VBW

300 kHz

Detector(s) Peak and Average (RMS)

Notes
Example Calculations

Declared antenna gain for band edge ­ 2.5 dBi
Correction Factor = 20 log (1/D), where D is the duty cycle EIRP = Measurement + Antenna Gain + Correction Factor E-Field = EIRP ­ 20log3 + 104.8

Instrumentation

Asset # AA 960172 EE 960085 EE 960087 AA 960173

Description
Cable
Analyzer ­ Spectrum Analyzer Spectrum
Cable

Manufacturer A.H. Systems,
Inc.
Agilent
Agilent
A.H. Systems, Inc.

Model # SAC-26G-1
N9010A N9010A SAC-26G-1

Serial # 387
MY53400296 MY53400296
388

Date 06/13/2023 04/11/2023 4/11/2023 6/13/2023

Due Date 06/12/2024 04/11/2024 4/11/2024 6/12/2024

Status Active Verification Active Calibration Active Calibration Active Verification

Input Power 120 VAC @ 60 Hz Frequency 2400-2483.5 MHz
Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Mode Channel
Page 18 of 36

BTC FHSS Tx
See 2.8
Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M Serial: 00047

Measurements ­ Lower Band Edge

Rate DH5 2DH5 3DH5

Channel 0
Hopping 0
Hopping 0
Hopping

Measurement Type Peak
Average Peak
Average Peak
Average Peak
Average Peak
Average Peak
Average

Frequency (MHz)
2388.5 2385.2 2388.1 2385.1 2361.8 2362.5 2385.7 2383.4 2361.8 2362.5 2377.9 2383.5

Measurement (dBm)
-42.1 -62.7 -44.5 -62.9 -55.8 -68.4 -56.3 -68.4 -54.2 -68.3 -54.4 -68.5

EIRP (dBm)
-39.6 -60.2 -42.0 -60.4 -53.3 -65.9 -53.8 -65.9 -51.7 -65.8 -51.9 -66.0

E-Field (dBµV/m)
55.7 35.1 53.3 34.9 42.0 29.4 41.5 29.4 43.6 29.5 43.4 29.3

Limit (dBµV/m))
74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0

Margin (dB)
18.3 18.9 20.7 19.1 32.0 24.6 32.5 24.6 30.4 24.5 30.6 24.7

Measurements ­ Upper Band Edge

Rate DH5 2DH5 3DH5

Channel 78
Hopping 78
Hopping 78
Hopping

Measurement Type Peak
Average Peak
Average Peak
Average Peak
Average Peak
Average Peak
Average

Frequency (MHz)
2487.5 2483.5 2492.0 2483.7 2483.5 2483.5 2484.1 2483.5 2483.5 2483.5 2483.5 2483.5

Measurement (dBm)
-38.0 -61.2 -42.0 -62.6 -41.1 -63.8 -44.0 -64.4 -41.6 -63.4 -44.5 -63.7

EIRP (dBm)
-35.5 -58.7 -39.5 -60.1 -38.6 -61.3 -41.5 -61.9 -39.1 -60.9 -42.0 -61.2

E-Field (dBµV/m)
59.8 36.6 55.8 35.2 56.7 34.0 53.8 33.4 56.2 34.4 53.3 34.1

Limit (dBµV/m))
74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0

Margin (dB)
14.2 17.4 18.2 18.8 17.3 20.0 20.2 20.6 17.8 19.6 20.7 19.9

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 19 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

Worst Case Plots ­ Band Edge

Channel 0 | DH5 | 2310-2390 MHz | Peak

Channel 0 | DH5 | 2310-2390 MHz | Average

Channel 78 | DH5 | 2483.5-2500 MHz | Peak Channel 78 | DH5 | 2483.5-2500 MHz | Average

Hopping | 3DH5 | 2310-2390 MHz | Peak

Hopping | 3DH5 | 2310-2390 MHz | Average

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 20 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

Hopping | DH5 | 2483.5-2500 MHz | Peak

Hopping | DH5 | 2483.5-2500 MHz | Average

Measurements - Spurious

Rate DH5 2DH5 3DH5

Channel 0 39 78 0 78

Measurement Type Peak
Average Peak
Average Peak
Average Peak
Average Peak
Average

Frequency (MHz)
1217.7 1224.6 2281.1 2281.2 2801.0 2799.8 2725.0 2721.8 3DH5 3DH5

Measurement (dBm)
-59.6 -77.7 -53.5 -69.3 -50.5 -75.2 -51.8 -75.2 2802.1 2800.0

EIRP (dBm)
-57.1 -75.2 -51.0 -66.8 -48.0 -72.7 -49.3 -72.7 -50.7 -75.2

E-Field (dBµV/m)
38.2 20.1 44.3 28.5 47.3 22.6 46.0 22.6 -48.2 -72.7

Limit (dBµV/m))
74.0 54.0 74.0 54.0 74.0 54.0 74.0 54.0 47.1 22.6

Margin (dB)
35.8 33.9 29.7 25.5 26.7 31.4 28.0 31.4 74.0 54.0

Worst Case Plots - Spurious

Channel 0 | DH5 | 30-1000 MHz

Channel 0 | 2DH5 | 1000-2310 MHz

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 21 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

Channel 78 | 3DH5 | 2500-4000 MHz

Channel 0 | DH5 | 4000-40000 MHz

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 22 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

6.1.5 Frequency Stability | Channel Separation | Number of Hopping Frequencies | Time of Occupancy

Operator

Dylan Rosenfeldt

Temperature 21.6°C | 22.0°C

Test Date Requirement

04/24/2024-04/25/2024
15.247(a)(1) 2.1055 (d) RSS-247 Clause 5.1 RSS-GEN Clause 6.11

QA R.H. % Location
Method

Anthony Smith 30.00% | 29.10% Conducted RF Bench
ANSI C63.10

Test Parameters

Frequency Detector(s)

2402-2480 MHz Peak

Voltage Settings

4.3 VDC, 5 VDC, and 5.8 VDC Max Hold

Instrumentation

Asset # AA 960173 EE 960088

Description
Cable
Analyzer - EMI Receiver

Manufacturer A.H. Systems,
Inc.
Agilent

Model # SAC-26G-1
N9038A

Serial # 387
MY51210138

Date 06/13/2023 4/10/2023

Due Date 06/12/2024 4/10/2024

Status Active Verification Active Calibration

Frequency Stability Table

Channel 0 39 78

Voltage (VDC)
5 4.3 5.8 5 4.3 5.8 5 4.3 5.8

Center Frequency (Hz)
2401999913 2401999390 2402000063 2440999125 2440998913 2440999248 2480000066 2480000109 2480000138

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 23 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

Carrier Frequency Separation

1DH5 | 1.006 MHz

2DH5 | 1.001 MHz

3DH5 | 1.005 MHz

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 24 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

Dwell Time

Rate

Length of Transmission on Time (ms)

1DH5

2.892

1DH3

1.645

1DH1

0.388

Number of Transmissions in 31.6s (79 Hopping *0.4) 126.4 180.1 350

Result (s)
0.366 0.296 0.136

Limit (s)
0.400 0.400 0.400

Margin (s)
0.034 0.104 0.264

Plots

1DH5 | 2.892 ms

1DH5 | 40 hops / 10 seconds

1DH3 | 1.645 ms

1DH3 | 57 hops / 10 seconds

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 25 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

1DH1 | 388 µs

1DH1 | 35 hops / 3.16 seconds

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 26 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

6.2 Radiated Emissions

The frequency spectrum is investigated for intentional and / or unintentional signals emanating from the EUT by use of a standardized test site and measurement antenna.

Description of Measurement

The antenna, cable, pre-amp, and other necessary measurement system correction factors are loaded onto the EMI receiver / spectrum analyzer when the measurements are performed allowing the data to be gathered and reported as corrected values.

The maximum emissions from the EUT are determined by turn-table azimuth rotation (360°) and scanning of the measurement antenna. Maximized levels are noted at degree values of azimuth, measurement antenna height, and measurement antenna polarity.

Measurement (dBµV) + Cable factor (dB) + Other (dB) + Antenna Factor (dB/m) = Corrected Reading (dBµV/m)

Example Calculations

Margin (dB) = Limit (dBµV/m) - Corrected Reading (dBµV/m)
Example at 4000 MHz: Reading = 40 dBµV + 3.4 dB + 0.9 dB + 6.5 dB/m = 50.8 dBµV/m Average Limit = 20 log (500) = 54 dBµV/m Margin = 54 dBµV/m - 50.8 dBµV/m = 3.2 dB

Block Diagram

EMI

Receiver / Spectrum

Antenna

EUT

Analyzer

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 27 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

6.2.1 Spurious Radiated Emissions in the Restricted Bands

Operator

Mitchell Freund | Nicole Sedmak Jon Dilley | Zachary Brown

Temperature 23.4°C-24.0°C

QA R.H. %

Anthony Smith | Adam Alger Adam Hauke | Dylan Rosenfeldt
19.90%-32.40%

Test Date Requirement

03/14/2024-03/21/2024
15.247 (d) | 15.209 RSS-247 Clause 5.5 RSS-GEN Clause 8.9

Location Method

Chamber 3 | Chamber 5 ANSI C63.10

15.209 Limits:
Frequency (MHz)
30-88 88-216 216-960 960-1000 1000-40000

Quasi-Peak Limit (dBµV/m) 40.0 43.5 46.0 54.0 -

Average Limit (dBµV/m) 54.0

Peak Limit (dBµV/m)
74.0

Test Parameters

Frequency Detector(s) RBW

30-40000 MHz
Peak Trace Peak and Average Final <1000 MHz ­ 120 kHz >1000 ­ 1 MHz

Distance

3 m

Table height VBW

150 cm
<1000 ­ 1.2 MHz >1000 ­ See 2.9

Instrumentation

Asset # AA 960007
AA 960081 AA 960154 AA 960163 AA 960217 AA 960221 EE 960085

Description Antenna Double Ridge
Horn Antenna Double Ridge
Horn Filter - High Pass 2.4 GHz Antenna - Log
Periodic Antenna Biconical
Cable
Analyzer EMI Receiver

Manufacturer
EMCO
EMCO
KWM A.H. Systems,
Inc. A.H. Systems,
Inc. A.H. Systems,
Inc. Agilent

Model # 3115
3115 HPF-L-14186
SAS-512-2 SAS-540 SAC-26G-6 N9038A

Serial # 9311-4138
6907 7272-02
500 852 524 MY51210148

Date 8/10/2023
1/11/2024 4/11/2023 8/10/2023 7/17/2023 6/13/2023 4/27/2023

Due Date 8/10/2024
1/11/2025 4/11/2024 8/10/2024 7/17/2024 6/13/2024 4/27/2024

Status
Active Calibration
Active Calibration
Active Calibration
Active Calibration
Active Calibration
Active Verification
Active Calibration

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 28 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

EE 960203 LSC-300 LSC-500

Analyzer EMI Receiver
Cable
Cable

Keysight
Chamber 3 Emissions Chamber 5 Emissions

N9038A -

MY56400072 -

4/11/2023 1/5/2024 1/8/2024

4/11/2024 1/5/2025 1/8/2025

Active Calibration
Active Verification
Active Verification

EUT Parameters

Input Power EUT Notes

120 VAC @ 60 Hz

Mode

BTC FHSS Tx

X, Y, Z Plane Orientations Antenna ports terminated with AE 50  SMA terminators

HP Elitebook 840G1 Ezurio ­ SOM60 Development Kit

6000 MHz Emission from auxiliary equipment. Not a function of the EUT.

Radiated Spurious ­ 30-1000 MHz ­ Channel 19 ­ Basic Rate - Single

Frequency (MHz)
44.0 64.8 77.0 84.0 131.7 132.3

Antenna Polarity
Vertical Horizontal
Vertical Horizontal Horizontal
Vertical

Height (cm)
102 281 101 228 230 100

Azimuth (degree)
254 158 138 164 201 49

Quasi-Peak Reading (dBµV/m) 32.1 34.8 26.3 29.1 27.7 34.2

Quasi-Peak Limit
(dBµV/m) 40.0 40.0 40.0 40.0 43.5 43.5

Margin (dB)
7.9 5.2 13.7 10.9 15.8 9.3

*The spurious signals detected do not depend on either the operating channel or the modulation mode

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 29 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

1000-40000 MHz

Band Edge

Channel 0
39

EUT Orientation
Z Plane
Z Plane

Data Rate BR (Single) BR (Hopping) EDR2 (Single) EDR2 (Hopping) EDR# (Single) EDR (Hopping) BR (Single) BR (Hopping) EDR2 (Single) EDR2 (Hopping) EDR# (Single) EDR (Hopping)

Measurement Type Peak
Average Peak
Average Peak
Average Peak
Average Peak
Average Peak
Average Peak
Average Peak
Average Peak
Average Peak
Average Peak
Average Peak
Average

Frequency (MHz) 2345.2 2387.9 2349.9 2378.6 2388.5 2386.0 2341.3 2388.3 2370.8 2389.7 2334.9 2384.4 2489.4 2491.9 2493.1 2485.1 2497.0 2493.6 2495.9 2495.2 2486.0 2497.9 2496.5 2498.6

Antenna Polarity Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal

Measurement (dBµV/m) 47.1 34.9 46.8 34.9 47.3 34.9 46.9 35.0 46.8 34.9 46.4 34.8 47.6 35.0 47.6 35.0 47.2 35.0 47.0 35.0 47.0 35.0 46.8 35.0

Limit (dBµV/m)
68.2 54.0 68.2 54.0 68.2 54.0 68.2 54.0 68.2 54.0 68.2 54.0 68.2 54.0 68.2 54.0 68.2 54.0 68.2 54.0 68.2 54.0 68.2 54.0

Margin (dB) 21.1 19.1 21.4 19.1 20.9 19.1 21.3 19.0 21.4 19.1 21.8 19.2 20.6 19.0 20.6 19.0 21.0 19.0 21.2 19.0 21.2 19.0 21.4 19.1

Spurious No Emissions Present

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 30 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

Worst Case Plots

Channel 39 | Basic Rate | Single 30-200 MHz | Vertical

Channel 39 | Basic Rate | Single 200-1000 MHz | Horizontal

Channel 0 | Basic Rate | Single 1000-2310 MHz | Horizontal

Channel 78 | Basic Rate | Single 2500-4000 MHz | Horizontal

Channel 39 | Basic Rate | Single 4000-18000 MHz | Vertical

Channel 39 | Basic Rate | Single 18000-25000 MHz | Horizontal

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 31 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

Channel 39 | Basic Rate | Single 25000-40000 MHz | Horizontal

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 32 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

6.3 AC Mains Conducted Emissions

A line impedance stabilization network (LISN) or artificial mains network (AMN) allows the emissions of the power supply conductors to be measured while isolating the EUT from the supply mains.

The AMN, cable, and other necessary measurement system correction factors are

Description of Measurement

loaded onto the EMI receiver when the measurements are performed. The data is

gathered and reported as the corrected values.

Maximum emissions are determined with a peak max hold trace then measurements at a selection of the highest points are made with quasi-peak and average detectors. Results are recorded and compared to limit for each line. (e.g. line and neutral)

Example Calculations

Measurement (dBµV) + Cable factor (dB) + Other (dB) = Corrected Reading (dBµV) Margin (dB) = Limit (dBµV) - Corrected Reading (dBµV)

Block Diagram

EUT

AMN

Cable

EMI Receiver

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 33 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

6.3.1 AC Mains Conducted Emissions

Operator

Jon Dilley

Temperature 20.8°C

Test Date 1/22/2024

Requirement

15.207 RSS-GEN Clause 8.8

QA R.H. % Location Method

Adam Hauke 19.60% AC Conducted Bench ANSI C63.10

Limits:

Frequency (MHz)

Quasi-Peak Limit (dBµV)

0.15-0.5

66.0-56.0*

0.5-5

56.0

5-30

60.0

*Decreases with the logarithm of the frequency.

Average Limit (dBµV) 56.0-46.0* 46.0 50.0

Test Parameters

Frequency Detector(s) RBW Notes

0.15-30 MHz

Distance

Peak Trace Quasi-Peak, Average Final
9 kHz

Table height VBW

Channel has no effect on emission

40 cm from wall 80 cm from LISN 80 cm
62 kHz

Instrumentation

Asset # EE 960088 EE 960089

Description Analyzer - EMI
Receiver
LISN

Manufacturer Agilent
COM-POWER

Model # N9038A LI-215A

Serial # MY51210148
191943

EE 960162 LSC-212

LISN Cable

COM-POWER Micro-Coax

LI-215A
UFB311A-01440-70U70U

191969
64639 224071001

Date 4/27/2023 4/10/2023 4/10/2023 1/8/2024

Due Date 4/27/2024 4/10/2024 4/10/2024 1/8/2025

Status Active Calibration Active Calibration Active Calibration Active Verification

EUT Parameters Input Power 120 VAC @ 60 Hz

Mode

BTC Tx Channel 37 1DH5

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 34 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

Measurements

Line

Frequency (MHz)

1

0.155

1

0.512

1

11.760

2

0.150

2

0.517

2

11.860

Quasi Peak Reading (dBµV) 39.3 30.2 36.0 39.7 30.8 30.2

QuasiPeak Limit
(dBµV)
65.8 56.0 60.0 66.0 56.0 60.0

Quasi Peak Margin (dB) 26.5 25.8 24.0 26.3 25.2 29.8

Plots

Average Reading (dBµV)
29.6 24.2 25.1 30.2 23.6 18.1

Average Limit (dBµV)
55.8 46.0 50.0 56.0 46.0 50.0

Average Margin
(dB)
26.2 21.8 24.9 25.8 22.4 31.9

Line 1

Line 2

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 35 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047

7 REVISION HISTORY

Version 0.0 1.0

Date 08/05/2024 08/08/2024

Notes Initial Draft Final Draft

END OF REPORT

Person Adam Hauke Adam Hauke

Company: Ezurio
Report: TR3768-166-BTC-FHSS Job: C-3768

Page 36 of 36

Name: Module, SONA NX611 M.2 2230, 1 MHF Model: SONA NX611M
Serial: 00047



Related FCC IDs:

Search Any Device: