HD 271 S1

LAB02

Test report

NLU Products, LLC dba BGZ brands BLDCTT20 Lantern 2ALQR-BLDCTT20 2ALQRBLDCTT20 bldctt20

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 18 Pages, 2.29MB

Document DEVICE REPORTGetApplicationAttachment.html?id=5066247
JianYan Testing Group Shenzhen Co., Ltd.
Report No: JYTSZE201102603V01
1 Cover Page
FCC REPORT

Applicant: Address of Applicant:

NLU Products, L.L.C. 2801 N Thanksgiving Way #300, Lehi, UT 84043 USA

Equipment Under Test (EUT)

Product Name:

Lantern

Model No.:

Boulder

Trade mark:

Lander

FCC ID:

2ALQR-BLDCTT20

Applicable standards: FCC CFR Title 47 Part 15 Subpart B

Date of sample receipt: 30 Nov., 2020

Date of Test:

01 Dec., to 09 Dec., 2020

Date of report issued: 30 Dec., 2020

Test Result:

PASS *

* In the configuration tested, the EUT complied with the standards specified above.

Authorized Signature:

Bruce Zhang Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other samples of the same product and does not permit the use of the JYT product certification mark. The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report.
This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards.
This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only.

2 Version
Version No. 00 01

Report No: JYTSZE201102603V01

Date 10 Dec., 2020 30 Dec., 2020

Description Original
Update section 5.2

Tested by:

Test Engineer

Date:

30 Dec., 2020

Reviewed by:

Project Engineer

Date:

30 Dec., 2020

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 2 of 18

Report No: JYTSZE201102603V01
3 Contents
Page
1 COVER PAGE.......................................................................................................................................................1
2 VERSION ...............................................................................................................................................................2
3 CONTENTS ...........................................................................................................................................................3
4 TEST SUMMARY..................................................................................................................................................4
5 GENERAL INFORMATION..................................................................................................................................5
5.1 CLIENT INFORMATION ......................................................................................................................................................5 5.2 GENERAL DESCRIPTION OF E.U.T. ......................................................................................................................................5 5.3 TEST MODE AND TEST SAMPLES PLANS ................................................................................................................................5 5.4 MEASUREMENT UNCERTAINTY...........................................................................................................................................6 5.5 DESCRIPTION OF SUPPORT UNITS .......................................................................................................................................6 5.6 RELATED SUBMITTAL(S) / GRANT (S)...................................................................................................................................6 5.7 DESCRIPTION OF CABLE USED ............................................................................................................................................6 5.8 ADDITIONS TO, DEVIATIONS, OR EXCLUSIONS FROM THE METHOD .............................................................................................6 5.9 LABORATORY FACILITY......................................................................................................................................................6 5.10 LABORATORY LOCATION...............................................................................................................................................6 5.11 TEST INSTRUMENTS LIST...............................................................................................................................................7
6 TEST RESULTS AND MEASUREMENT DATA ................................................................................................8
6.1 CONDUCTED EMISSION.....................................................................................................................................................8 6.2 RADIATED EMISSION ......................................................................................................................................................11
7 TEST SETUP PHOTO ........................................................................................................................................ 17
8 EUT CONSTRUCTIONAL DETAILS ................................................................................................................18

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 3 of 18

Report No: JYTSZE201102603V01

4 Test Summary

Test Item

Section in CFR 47

Conducted Emission

Part 15.107

Radiated Emission

Part 15.109

Remark: 1. Pass: The EUT complies with the essential requirements in the standard. 2. N/A: The EUT not applicable of the test item. Test Method: ANSI C63.4:2014

Result Pass Pass

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 4 of 18

Report No: JYTSZE201102603V01

5 General Information

5.1 Client Information

Applicant: Address: Manufacturer: Address: Factory: Address:

NLU Products, L.L.C. 2801 N Thanksgiving Way #300, Lehi, UT 84043 USA NLU Products, L.L.C. 2801 N Thanksgiving Way #300, Lehi, UT 84043 USA CTT Co., Ltd Building 2 of Industrial park, No. 197, Xinhua Blvd, Tongqiao town, Zhongkai High-tech zone, Huizhou, Guangdong, China 516032.

5.2 General Description of E.U.T.

Product Name: Model No.: Type-C:
Type-A:
Power supply: (Wireless charging) Power supply: Test Sample Condition:

Lantern Boulder Charge-In : DC5 V, 3.0 A; DC9 V, 2.0 A; DC12 V, 1.5 A Charge-Out: DC5 V, 3.0 A; DC9 V, 2.0 A; DC12 V, 1.5 A Charge-Out: DC 5V, 2.4 A
DC 5V, 1 A Input: 5V, 3A / 9V, 2A /12V, 1.5A Output: 5W, 7.5W Lithium-ion rechargeable battery DC3.63V, each 3350mAh * 4 total 13400mAh The test samples were provided in good working order with no visible defects.

5.3 Test Mode and test samples plans

Operating mode

Detail description

Discharging + Working mode Discharging + Working mode

Keep the EUT in Discharging + Wireless charging work + Turn on the light mode(Port A) Keep the EUT in Discharging + Wireless charging work + Turn on the light mode(Port C)

Charging + Working mode Charging + Working mode

Keep the EUT in Charging + Wireless charging work + Turn on the light mode(Port A) Keep the EUT in Charging + Wireless charging work +Turn on the light mode(Port C)

The sample was placed 0.8m above the ground plane of 3m chamber. Measurements in both horizontal and vertical polarities were performed. During the test, each emission was maximized by: having the EUT continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable, varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case are shown in Test Results of the following pages.

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 5 of 18

Report No: JYTSZE201102603V01

5.4 Measurement Uncertainty
Parameters Conducted Emission (9kHz ~ 30MHz) Radiated Emission (9kHz ~ 30MHz) Radiated Emission (30MHz ~ 1000MHz) Radiated Emission (1GHz ~ 18GHz) Radiated Emission (18GHz ~ 40GHz)

Expanded Uncertainty ±1.60 dB (k=2) ±3.12 dB (k=2) ±4.32 dB (k=2) ±5.16 dB (k=2) ±3.20 dB (k=2)

5.5 Description of Support Units

Manufacturer Skytek Apple

Description
Wireless charging match load
Adapter

Model /
A1695

Serial Number FCC ID/DoC

/

/

N/A

N/A

5.6 Related Submittal(s) / Grant (s)

This is an original grant, no related submittals and grants.

5.7 Description of Cable Used

Cable Type Detached USB Cable

Description Shielding

Length 0.3m

From EUT

To Adapter

5.8 Additions to, deviations, or exclusions from the method
No

5.9 Laboratory Facility
The test facility is recognized, certified, or accredited by the following organizations:
 FCC - Designation No.: CN1211 JianYan Testing Group Shenzhen Co., Ltd. has been accredited as a testing laboratory by FCC(Federal Communications Commission). The test firm Registration No. is 727551.
 ISED ­ CAB identifier.: CN0021 The 3m Semi-anechoic chamber of JianYan Testing Group Shenzhen Co., Ltd. has been Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration No.: 10106A-1.
 A2LA - Registration No.: 4346.01 This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. The test scope can be found as below link: https://portal.a2la.org/scopepdf/4346-01.pdf

5.10 Laboratory Location
JianYan Testing Group Shenzhen Co., Ltd. Address: No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Tel: +86-755-23118282, Fax: +86-755-23116366 Email: [email protected], Website: http://www.ccis-cb.com

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 6 of 18

Report No: JYTSZE201102603V01

5.11 Test Instruments list

Radiated Emission:

Test Equipment

Manufacturer

3m SAC Loop Antenna BiConiLog Antenna Horn Antenna Horn Antenna Horn Antenna
EMI Test Software Pre-amplifier Pre-amplifier
Spectrum analyzer Spectrum analyzer
EMI Test Receiver Cable Cable Cable

SAEMC SCHWARZBECK SCHWARZBECK SCHWARZBECK SCHWARZBECK SCHWARZBECK
AUDIX HP CD
Rohde & Schwarz Rohde & Schwarz
Rohde & Schwarz ZDECL
MICRO-COAX SUHNER

Model No.
9m*6m*6m FMZB1519B VULB9163 BBHA9120D BBHA9120D BBHA 9170
E3 8447D PAP-1G18 FSP30 FSP40
ESRP7 Z108-NJ-NJ-81
MFR64639 SUCOFLEX100

Serial No.

Cal. Date (mm-dd-yy)

Cal. Due date (mm-dd-yy)

966

07-22-2020

07-21-2021

00044

03-07-2020

03-06-2021

497

03-07-2020

03-06-2021

916

03-07-2020

03-06-2021

1805

06-22-2020

06-21-2021

BBHA9170582 11-18-2020

11-17-2021

Version: 6.110919b

2944A09358 03-07-2020

03-06-2021

11804

03-07-2020

03-06-2021

101454

03-05-2020

03-04-2021

100363

11-18-2020

11-17-2021

101070

03-05-2020

03-04-2021

1608458

03-07-2020

03-06-2021

K10742-5

03-07-2020

03-06-2021

58193/4PE

03-07-2020

03-06-2021

Conducted Emission:
Test Equipment
EMI Test Receiver Pulse Limiter LISN LISN Cable
EMI Test Software

Manufacturer
Rohde & Schwarz SCHWARZBECK
CHASE Rohde & Schwarz
HP AUDIX

Model No.
ESCI OSRAM 2306
MN2050D ESH3-Z5 10503A
E3

Serial No.

Cal. Date (mm-dd-yy)

Cal. Due date (mm-dd-yy)

101189

03-05-2020

03-04-2021

9731

03-05-2020

03-04-2021

1447

03-05-2020

03-04-2021

8438621/010 06-18-2020

06-17-2021

N/A

03-05-2020

03-04-2021

Version: 6.110919b

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 7 of 18

Report No: JYTSZE201102603V01

6 Test results and Measurement Data

6.1 Conducted Emission

Test Requirement: Test Frequency Range: Class / Severity: Receiver setup: Limit:
Test setup:

FCC Part 15 B Section 15.107

150kHz to 30MHz

Class B

Class B

RBW=9kHz, VBW=30kHz

Frequency range (MHz)

Limit (dBµV)

Quasi-peak

Average

0.15-0.5

66 to 56*

56 to 46*

0.5-5

56

46

0.5-30

60

50

* Decreases with the logarithm of the frequency.

Test procedure
Test Instruments: Test mode: Test results:

1. The E.U.T and simulators are connected to the main power through a line impedance stabilization network(L.I.S.N.). The provide a 50ohm/50uH coupling impedance for the measuring equipment.
2. The peripheral devices are also connected to the main power through a LISN that provides a 50ohm/50uH coupling impedance with 50ohm termination. (Please refers to the block diagram of the test setup and photographs).
3. Both sides of A.C. line are checked for maximum conducted interference. In order to find the maximum emission, the relative positions of equipment and all of the interface cables must be changed according to ANSI C63.4(latest version) on conducted measurement.
Refer to section 5.11 for details
Refer to section 5.3 for details
Pass

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 8 of 18

Measurement data:

Product name:

Lantern

Test by:

YT

Test frequency:

150 kHz ~ 30 MHz

Test voltage:

AC 120 V/60 Hz

Report No: JYTSZE201102603V01

Product model: Test mode: Phase: Environment:

Boulder Working mode Line Temp: 22.5 Huni: 55%

Notes: 1. An initial pre-scan was performed on the line and neutral lines with peak detector. 2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission. 3. Final Level =Receiver Read level + LISN Factor + Cable Loss.

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 9 of 18

Product name: Test by: Test frequency: Test voltage:

Lantern YT 150 kHz ~ 30 MHz AC 120 V/60 Hz

Report No: JYTSZE201102603V01

Product model: Test mode: Phase: Environment:

Boulder Working mode Neutral Temp: 22.5

Huni: 55%

Notes: 1. An initial pre-scan was performed on the line and neutral lines with peak detector. 2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission. 3. Final Level =Receiver Read level + LISN Factor + Cable Loss.

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 10 of 18

Report No: JYTSZE201102603V01

6.2 Radiated Emission

Test Requirement: Test Frequency Range: Test site: Receiver setup:
Limit:
Test setup:

FCC Part 15 B Section 15.109

30MHz to 6000MHz

Measurement Distance: 3m (Semi-Anechoic Chamber)

Frequency 30MHz-1GHz

Detector Quasi-peak

RBW

VBW

Remark

120kHz 300kHz Quasi-peak Value

Above 1GHz

Peak RMS

Frequency

30MHz-88MHz

88MHz-216MHz

216MHz-960MHz

960MHz-1GHz

Above 1GHz

1MHz

3MHz

1MHz

3MHz

Limit (dBuV/m @3m)

40.0

43.5

46.0

54.0

54.0

74.0

Peak Value Average Value
Remark Quasi-peak Value Quasi-peak Value Quasi-peak Value Quasi-peak Value
Average Value Peak Value

Below 1GHz

Above 1GHz

Test Procedure:

1. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter semi-anechoic camber. The table was rotated 360 degrees to determine the position of the highest radiation.
2. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower.
3. The antenna height is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement.

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 11 of 18

Test Instruments: Test mode: Test results: Remark:

Report No: JYTSZE201102603V01
4. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to find the maximum reading.
5. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode.
6. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that did not have 10dB margin would be re-tested one by one using peak, quasi-peak or average method as specified and then reported in a data sheet.
Refer to section 5.11 for details
Refer to section 5.3 for details
Passed
All of the observed value above 6GHz ware the niose floor , which were no recorded

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 12 of 18

Measurement Data: Below 1GHz:

Product Name:

Lantern

Test By:

YT

Test Frequency:

30 MHz ~ 1 GHz

Test Voltage:

AC 120/60Hz

Report No: JYTSZE201102603V01

Product Model: Test mode: Polarization: Environment:

Boulder Boulder Working mode Vertical Temp: 24 Huni: 57%

Remark: 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss ­ Preamplifier Factor. 2. The emission levels of other frequencies are very lower than the limit and not show in test report. 3. The Aux Factor is a notch filter switch box loss, this item is not used.

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 13 of 18

Product Name: Test By: Test Frequency: Test Voltage:

Lantern YT 30 MHz ~ 1 GHz AC 120/60Hz

Report No: JYTSZE201102603V01

Product Model: Test mode: Polarization: Environment:

Boulder

Working mode

Horizontal Temp: 24

Huni: 57%

Remark: 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss ­ Preamplifier Factor. 2. The emission levels of other frequencies are very lower than the limit and not show in test report. 3. The Aux Factor is a notch filter switch box loss, this item is not used.

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 14 of 18

Above 1GHz: Product Name: Test By: Test Frequency: Test Voltage:

Lantern YT 1 GHz ~ 6 GHz AC 120/60Hz

Report No: JYTSZE201102603V01

Product Model: Test mode: Polarization: Environment:

Boulder Working mode Vertical Temp: 24 Huni: 57%

Remark: 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss ­ Preamplifier Factor. 2. The emission levels of other frequencies are very lower than the limit and not show in test report.

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 15 of 18

Product Name: Test By: Test Frequency: Test Voltage:

Lantern YT 1 GHz ~ 6 GHz AC 120/60Hz

Report No: JYTSZE201102603V01

Product Model: Test mode: Polarization: Environment:

Boulder

Working mode

Horizontal Temp: 24

Huni: 57%

Remark: 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss ­ Preamplifier Factor. 2. The emission levels of other frequencies are very lower than the limit and not show in test report.

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 16 of 18

7 Test Setup Photo

Report No: JYTSZE201102603V01
Radiated Emission Below 1GHz

Above 1GHz

JianYan Testing Group Shenzhen Co., Ltd. No.110~116, Building B, Jinyuan Business Building, Xixiang Road, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366

Project No.: JYTSZE2011026 Page 17 of 18

Report No: JYTSZE201102603V01
Conducted Emission

8 EUT Constructional Details
Reference to the test report No.: JYTSZE201102601.
------End of report------