A4RGLU0G RFExp WPT

Google LLC GLU0G Phone A4RGLU0G A4RGLU0G glu0g

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 5 Pages, 290.45KB

Document DEVICE REPORTGetApplicationAttachment.html?id=5397972
FCC RF Exposure Report

Report No. : FA121931-05B

WPT Evaluation Report

FCC ID Equipment Model Name Applicant
Standard

: A4RGLU0G : Phone : GLU0G : Google LLC
1600 Amphitheatre Parkway, Mountain View, California, 94043 USA : FCC CFR 47 part 1, 1.1307(b) and 1.1310 KDB 680106 D01v03

We, SPORTON INTERNATIONAL INC., would like to declare that the tested sample provide by manufacturer and the test data has been evaluated in accordance with the test procedures given in 47 CFR part 1, 1.1307(b), 1.1310 and FCC KDB and has been pass the FCC requirement.
The test results in this report apply exclusively to the tested model / sample. Without written approval of SPORTON INTERNATIONAL INC., the test report shall not be reproduced except in full.

Approved by: Cona Huang / Deputy Manager
Sporton International Inc. EMC & Wireless Communications Laboratory
No. 52, Huaya 1st Rd., Guishan Dist., Taoyuan City, Taiwan

SPORTON INTERNATIONAL INC. TEL : 886-3-327-3456 FAX : 886-3-328-4978

Page Number

: 1 of 5

Report Issued Date : Aug. 17, 2021

Report Version

: Rev. 01

FCC RF Exposure Report
Table of Contents

Report No. : FA121931-05B

1. DESCRIPTION OF EQUIPMENT UNDER TEST (EUT) ............................................................................. 4 2. RF EXPOSURE LIMIT INTRODUCTION .................................................................................................... 4 3. TEST MODE ................................................................................................................................................ 5 4. MEASUREMENT EQUIPMENT...................................................................................................................5 5. RF EXPOSURE EVALUATION ................................................................................................................... 5 Appendix A. Test Setup Photo

SPORTON INTERNATIONAL INC. TEL : 886-3-327-3456 FAX : 886-3-328-4978

Page Number

: 2 of 5

Report Issued Date : Aug. 17, 2021

Report Version

: Rev. 01

FCC RF Exposure Report

Revision History

REPORT NO. VERSION

DESCRIPTION

FA121931-05B Rev. 01 Initial issue of report

Report No. : FA121931-05B
ISSUED DATE Aug. 17, 2021

SPORTON INTERNATIONAL INC. TEL : 886-3-327-3456 FAX : 886-3-328-4978

Page Number

: 3 of 5

Report Issued Date : Aug. 17, 2021

Report Version

: Rev. 01

FCC RF Exposure Report
1. Description of Equipment Under Test (EUT)

EUT Type Model Name FCC ID Frequency Range Moudlation Type Antenna Type Date of Test

Product Feature & Specification Phone GLU0G A4RGLU0G 110KHz ~ 148.5KHz ASK Loop Jul. 20, 2021

Report No. : FA121931-05B

2. RF Exposure Limit Introduction
§ 1.1310 The criteria listed in table 1 shall be used to evaluate the environmental impact of human exposure to radio frequency(RF) radiation as specified in § 1.1307(b), except in the case of portable devices which shall be evaluated according to the provisions of § 2.1093 of this chapter.

(1) Occupational/controlled exposure limits apply in situations in which persons are exposed as a consequence of their employment provided those persons are fully aware of the potential for exposure and can exercise control over their exposure. Limits for occupational/controlled exposure also apply in situations when a person is transient through a location where occupational/controlled limits apply provided he or she is made aware of the potential for exposure. The phrase fully aware in the context of applying these exposure limits means that an exposed person has received written and/or verbal information fully explaining the potential for RF exposure resulting from his or her employment. With the exception of transient persons, this phrase also means that an exposed person has received appropriate training regarding work practices relating to controlling or mitigating his or her exposure. Such training is not required for transient persons, but they must receive written and/or verbal information and notification (for example, using signs) concerning their exposure potential and appropriate means available to mitigate their exposure. The phrase exercise control means that an exposed person is allowed to and knows how to reduce or avoid exposure by administrative or engineering controls and work practices, such as use of personal protective equipment or time averaging of exposure.
(2) General population/uncontrolled exposure limits apply in situations in which the general public may be exposed, or in which persons who are exposed as a consequence of their employment may not be fully aware of the potential for exposure or cannot exercise control over their exposure.

SPORTON INTERNATIONAL INC. TEL : 886-3-327-3456 FAX : 886-3-328-4978

Page Number

: 4 of 5

Report Issued Date : Aug. 17, 2021

Report Version

: Rev. 01

FCC RF Exposure Report
3. Test Mode

This device has been tested in the following charging conditions as below:

Test Mode

Test Setup Configuration

TM1

Test w/ Client Device installed

TM2

Test w/ Client Device installed

TM3

Test w/ Client Device installed

Report No. : FA121931-05B
Charging Current Condition < 1% Battery status 50% Battery status
Near 100% Battery status

4. Measurement Equipment

Instrument
Electric and Magnetic field Probe-Analyzey

Manufacturer Narda S.T.S / PMM

Model No. EHP 200AC

Serial No.

Freq Rang

Last Cal.

Due Date

170WX80309 3KHz~30MHz Sep. 12, 2020 Sep. 11, 2021

5. RF Exposure Evaluation
1. The device support Wireless Power Consortium with a maximum power transfer to the phone of 5W. In addition, the device can be used in reverse, as a transmitter to another wireless charging receiver. In this case, up to 5W (Baseline Power Profile) can be transmitted to the external receiver.
2. According to 201910 TCBC workshop, for portable devices that do not physically attach to phone, desktop WPT testing guidance from FCC KDB 680106 D01v03r01.
3. There is no mechanical / magnetic connection mechanism between client and smart phone (this application) so charging is only supported for desktop/tabletop use.
4. The equipment under test was placed on a wooden desk inside of shield room. The isotropic field probe was used to measure the field strength for 6 EUT surfaces, the detail setup photo please refer to Appendix A.
5. Per KDB 680106 D01v03r01, RF exposure evaluation at 15 cm surrounding the device and 20cm above the top surface. Emissions between 50 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1 of Section 1.1310: 1.63 A/m and aggregate H-field strengths from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.

Position
TM1 TM2 TM3

A (20cm) 0.0624 0.0593 0.0599

B (20cm) 0.0518 0.0516 0.0503

H-Field Measurement (A/m)

C (15cm)

D (15cm)

E (15cm)

0.0584

0.0593

0.0548

0.0576

0.0584

0.0541

0.0568

0.0571

0.0533

F (15cm) 0.0549 0.0543 0.0541

50% of limit 0.815

Conclusion:
The field strength limit refers to Part 1.1310 and the test result of exposure evaluation is compliant with 50% of the MPE limit. (H-field: 0.815A/m).

SPORTON INTERNATIONAL INC. TEL : 886-3-327-3456 FAX : 886-3-328-4978

Page Number

: 5 of 5

Report Issued Date : Aug. 17, 2021

Report Version

: Rev. 01



Related FCC IDs: