OM-KSACN0901-01

cbs1525

Owner’s Manual

Owner’s Manual Fig. 1 — Wired Controller NOTE: Images are for illustration purposes only. Actual models may differ slightly. Wired Remote Controller 7 Day Programmable Thermostat Ductless Systems KSACN0901AAA (High Wall) 2 Specifications subject to change without notice. OM-KSACN0901-01 TABLE OF CONTENTS ...

Owners Manual

Midea Wired Thermostats Programmable KSACN0601AAA KSACN0701AAA KSACN0901AAA

Owner's Manual for Carrier models including: KSACN0901AAA, Wired Remote Controller 7 Day Programmable Thermostat, 7 Day Programmable Thermostat, Thermostat

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 38 Pages, 3.97MB

Document DEVICE REPORT901 owners manual 1629801376222
Wired Remote Controller 7 Day Programmable Thermostat Ductless Systems KSACN0901AAA (High Wall)
Owner's Manual

Fig. 1 -- Wired Controller NOTE: Images are for illustration purposes only. Actual models may differ slightly.

Specifications subject to change without notice.

OM-KSACN0901-01

TABLE OF CONTENTS
PAGE
SAFETY CONSIDERATIONS...........................................................................................3 WIRED CONTROLLER FEATURES AND FUNCTIONS...............................................5 WIRED CONTROLLER DISPLAY ...................................................................................6 WIRED CONTROLLER FUNCTIONS .............................................................................7 INITIAL SETUP..................................................................................................................8 WEEKLY TIMER OPERATION .....................................................................................17 WEEK AND DAY SETTINGS FOR WEEK 2 ................................................................22 WIRED CONTROLLER ERROR CODES ......................................................................31 QUERIES AND SETTINGS .............................................................................................32 TECHNICAL INDICATION AND REQUIREMENT .....................................................38
NOTE: In order to properly service the wired controller, read this manual carefully prior to operating the unit. Keep this manual after reading for future reference.

2

Specifications subject to change without notice.

OM-KSACN0901-01

SAFETY CONSIDERATIONS
Installing, starting up, and servicing air-conditioning equipment can be hazardous due to system pressures, electrical components, and equipment location (roofs, elevated structures, etc.). Only trained, qualified installers and service mechanics should install, start-up, and service this equipment. Untrained personnel can perform basic maintenance functions such as cleaning coils.
When working on the equipment, observe precautions in the literature and on tags, stickers, and labels attached to the equipment.
Follow all safety codes. Wear safety glasses and work gloves. Keep a quenching cloth and fire extinguisher nearby when brazing. Use care in handling, rigging, and setting bulky equipment.
Read these instructions thoroughly and follow all warnings or cautions included in the literature and attached to the unit. Consult the local building codes and National Electrical Code (NEC) for special requirements. Recognize safety information.
This is the safety-alert symbol . When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand these signal words: DANGER, WARNING, and CAUTION. These words are used with the safety-alert symbol.
DANGER identifies the most serious hazards which will result in severe personal injury or death.
WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage.
NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.

OM-KSACN0901-01

Specifications subject to change without notice.

3

CAUTION
ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death. Before beginning any modification or installation of this kit, ensure the main electrical disconnect is in the OFF position. Ensure power is disconnected to the fan coil unit. On some systems both the fan coil and the outdoor unit may be on the same disconnect. Tag the disconnect switch with a suitable warning label. There may be more than one to disconnect.
CAUTION
EQUIPMENT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. Do not install the wired controller in an area subjected to excessive steam, oil or sulfide gas. Doing so may damage the controller and/or cause it to fail.

4

Specifications subject to change without notice.

OM-KSACN0901-01

WIRED CONTROLLER FEATURES AND FUNCTIONS

Features: · Display · Error code display · Room temperature display · Weekly Timer

Fig. 2 -- Wired Controller
Functions: · Modes: Auto - Cool - Dry - Heat - Fan · Fan speed: Auto/Low/Med/High speed · Swing (on some models) · Timer ON/OFF · Temp setting · Weekly timer · Follow Me · Child Lock · Display · Clock

OM-KSACN0901-01

Specifications subject to change without notice.

5

WIRED CONTROLLER DISPLAY

1

2

3

4 56 7

8
9 10

11

13

12

Fig. 3 -- Wired Controller Display

1. Operation Mode 2. Fan Speed 3. Temperature Display 4. Lock 5. F/C 6. Main and secondary units (not available) 7. Turbo 8. Room temperature 9. Follow ME

10. Left-Right Swing 11. Clock Display 12. On/Off Timer 13. Timer Display

6

Specifications subject to change without notice.

OM-KSACN0901-01

WIRED CONTROLLER FUNCTIONS
12

4 1 5 2
3
6
1. Power 2. Mode 3. Day Off/Del 4. Adjust 5. Confirm 6. Timer

7
8 9
10
11 Fig. 4 -- Wired Controller Functions
7. Fan Speed 8. Back 9. Swing 10. Function 11. Copy 12. IR (Infrared) Signal Receiver

OM-KSACN0901-01

Specifications subject to change without notice.

7

INITIAL SETUP
Set the current day and time
NOTE: The Wired Controller can be powered ON or OFF during this step.
1. Press TIMER for 2 seconds or more to set the current date and time. The TIMER display flashes (see Fig 5).

4. Press the UP or DOWN arrows (Fig. 6) to set the current time. Press repeatedly to adjust the current time in 1-minute increments. Press and hold to adjust the current time continuously. Press TIMER to confirm. If there is no button pressed within 10 seconds the displayed time is saved.

Fig. 5 --Timer
2. Press the UP or DOWN arrow (Fig. 6) to set the week day; the selected week day will flash (Fig. 7).

ex. Monday 11:20
Fig. 8 -- Week Day and Time
5. Time scale selection: Press TIMER (see Fig. 5) and DAY OFF (Fig. 9) for 2 seconds to alternate the clock time display between the 12 hour and 24 hour formats.

Fig. 6 --Up or Down Arrows

Fig. 7 -- Days of the Week
3. Press TIMER to confirm. If there is no button pressed within 10 seconds, the displayed week day will be saved.

Fig. 9 -- Timer

8

Specifications subject to change without notice.

OM-KSACN0901-01

Start and Stop Operation
· Press POWER (Fig. 10) to power on the controller.

Room Temperature Setting
1. Press the UP or DOWN arrow (Lower or Raise (see Fig.13)) to set the room temperature.
NOTE: This function in unavailable in FAN mode.

Raise

Fig. 10 -- Power
To Set the Operation Mode
· Press MODE (see Fig. 11) to set the OPERATION MODE (see Fig. 12) (HEAT function is invalid for a COOL only type unit).
Fig. 11 -- Mode

Lower
Fig. 13 -- Up or Down Arrows (Lower and Raise)
Indoor Setting Temperature Range: 62°F~86°F (17°C~30°C)
2. °F and °C Scale Selection - Press and hold the UP or DOWN arrow for 3 seconds to alternate the temperature display between the °F and °C scale.

Fig. 12 -- Operation Modes

OM-KSACN0901-01

Specifications subject to change without notice.

9

Fan Speed
· Press FAN SPEED to set the fan speed.
NOTE: This function is unavailable when the unit is in AUTO or DRY mode.

AUTO

LOW

MED

HIGH

Fig. 14 -- Fan Speed
Keypad Tone
Enable Keypad Tone · Press SWING and FUNC. together (Fig. 15)
for 3 seconds to enable the keypad tone.
Disable Keypad Tone · Press SWING and FUNC. together (Fig. 15)
for 3 seconds to disable the keypad tone.

Use the Child Lock Function
Activate the Child Lock · Press TIMER and COPY (Fig. 16) together
for 3 seconds to activate the CHILD LOCK function and lock all the buttons on the wired controller. When the CHILD LOCK function is activated, the LOCK icon appears (Fig. 17). De-activate the Child Lock · Press TIMER and COPY (Fig. 16) together for 3 seconds to deactivate the CHILD LOCK function.
Fig. 16 -- Timer and Copy
Fig. 17 -- Child Lock

Fig. 15 -- Keypad Tone Set

10

Specifications subject to change without notice.

OM-KSACN0901-01

Use the Swing (UP-DOWN) Function
(for some models only)
1. Press SWING (Fig. 18) for 2 seconds to start the UP-DOWN LOUVER SWING function. When the function is activated, the UP DOWN SWING icon appears (Fig. 19).
NOTE: For the KSACN0601AAA model, press SWING to start the UP-DOWN LOUVER SWING function. For the KSACN0701AAA model, press SWING for 2 seconds to start the UP-DOWN LOUVER SWING function.
2. Press SWING again to stop.

Turbo (on some models)
Under the COOL or HEAT mode, TURBO and FOLLOW ME can be activated.
1. Press FUNC. to set the TURBO or FOLLOW ME function. The select function icon flashes.
Fig. 21 -- FUNC.
2. Press CONFIRM to confirm the setting (see Fig. 22).

Fig. 18 -- Swing Fig. 19 -- Up-Down Swing
Use the Swing (LEFT-RIGHT) Function
(for some models only)
1. Press SWING (Fig. 18) for 2 seconds to start the LEFT-RIGHT SWING louver function.
2. Press SWING again for 2 seconds to stop.
When the LEFT-RIGHT SWING function is activated, the LEFT-RIGHT SWING icon appears (Fig. 20).

Fig. 22 -- Confirm the Setting
When TURBO is activated, the TURBO icon appears (see Fig. 23).
Fig. 23 -- Turbo

Fig. 20 -- Left-Right Swing

OM-KSACN0901-01

Specifications subject to change without notice.

11

FOLLOW ME

Activate FOLLOW ME

Deactivate FOLLOW ME

1. Press FUNC. to select the FOLLOW ME icon. 1. Press FUNC. to select the FOLLOW ME icon. 2. Press CONFIRM to activate FOLLOW ME. 2. Press CONFIRM to deactivate.

When the FOLLOW ME function indication appears, the room temperature is detected by the sensor in the wired controller.
Fig. 24 -- FOLLOW Me

Indoor Unit

12

Specifications subject to change without notice.

OM-KSACN0901-01

Timer Functions
For more information, see "To Set the ON or OFF TIMER" on page 14. · Weekly: Use the WEEKLY function to set operating times for each day of the week.
Fig. 25 -- WEEK
· On: Day: Use the ON:DAY function to start air conditioner operation.
Fig. 26 -- ON:DAY
· Off: Day: Use the OFF:DAY function to stop air conditioner operation.
Fig. 27 -- OFF:DAY
· On and Off: Day: Use the On and Off: Day function to start and stop air conditioner operation.
Fig. 28 -- ON and OFF:DAY

OM-KSACN0901-01

Specifications subject to change without notice.

13

To Set the ON or OFF TIMER
1. Press TIMER to select the ON:DAY or OFF:DAY.

No display

Fig. 29 -- Select the ON:DAY or OFF:DAY
2. Press CONFIRM and the TIMER display flashes.

Fig. 30 -- Confirm
3. Press the UP or DOWN arrow to set the time. After the time is set, the timer starts or stops.

4. Press CONFIRM.

ex. Off timer set at 18:00
Fig. 31 -- Up or Down arrow to set time

Fig. 32 -- Confirm

14

Specifications subject to change without notice.

OM-KSACN0901-01

Week and Day Settings for WEEK 1
WEEK 1 Timer Setting 1. Press TIMER (several times if needed) to select WEEK 1. 2. Press CONFIRM.
Fig. 33 -- Press Timer then Confirm
Day of the WEEK Setting 1. Press the UP or DOWN arrow to select the day of the week. 2. Press CONFIRM.
Fig. 34 -- Press Up and Down Arrows - Select Day - Confirm

OM-KSACN0901-01

Specifications subject to change without notice.

15

SET the ON Timer for Timer Setting 1
1. Press the UP or DOWN arrow to set the time of the ON timer. 2. Press CONFIRM.
Fig. 35 -- Up or Down Arrow - Confirm
ex.Tuesday time scale 1
Up to 4 timer settings can be saved for each day of the week.
Fig. 36 -- Select Timer Setting(s)
Set the OFF Timer Setting for Timer Setting 1
1. Press the UP or DOWN arrow to set the OFF timer. 2. Press CONFIRM.

ex. Tuesday time scale 1
Fig. 37 -- UP or DOWN Arrow - Confirm
NOTE: Users can revert to the previous step by pressing BACK. The time of the timer setting can be deleted by pressing DAY OFF. The current setting is restored and the weekly timer setting is withdrawn when there is no operation selected in 30 seconds.

16

Specifications subject to change without notice.

OM-KSACN0901-01

WEEKLY TIMER OPERATION
To activate the WEEKLY TIMER operation 1. Press and release TIMER until WEEK 1 appears on the display.

ex. Fig. 38 -- Press Timer
To deactivate the WEEKLY TIMER operation 1. Press and release TIMER until WEEK 1 no longer appears on the display.

ex. Fig. 39 -- Press Timer

OM-KSACN0901-01

Specifications subject to change without notice.

17

To Turn Off the Air Conditioner with the Week Timer
1. Press POWER and the air conditioner turns OFF temporarily. The air conditioner turns back on automatically when the ON timer's set time is reached. For example, press POWER once at 10:00 AM, the air conditioner turns back on at the timer setting 2:00 PM (Fig. 40).

ON

OFF

ON

OFF

8:00AM 10:00AM 12:00PM 2:00PM
Fig. 40 --Weekly Timer Display

5:00PM

2. Press POWER for 2 seconds, the air conditioner turns off completely and cancels the timing function.

18

Specifications subject to change without notice.

OM-KSACN0901-01

Set the DAY OFF For WEEK 1
1. Select WEEK 1 then press CONFIRM. For more information, see "WEEKLY TIMER OPERATION" on page 17.
Fig. 41 -- Confirm
2. Press the UP or DOWN arrow to select the day of the week.
Fig. 42 -- Up or Down Arrows
3. Press DAY OFF to select day(s) off.
The mark is hidden
ex. The DAY OFF is set for Wednesday
Fig. 43 -- Select Day(s) off
A DAY OFF can be set for other days by repeating steps 2 through 3. 4. Press BACK to revert to the weekly timer.

Fig. 44 -- Back
The DAY OFF setting is canceled at the end of the set day.

OM-KSACN0901-01

Specifications subject to change without notice.

19

Copy the Setting from One Day to Another
A scheduled event, made once, can be copied to another day of the week. The scheduled events of the selected day will also be copied to the new day.
1. During the weekly timer, press CONFIRM.

Fig. 45 -- Confirm
2. Press the UP or DOWN arrow to select the day to copy from.

Fig. 46 -- Up or Down Arrows
3. Press COPY, "CY" appears on the display.

Fig. 47 -- Copy
4. Press the UP or DOWN arrow to select the day to copy to.

Fig. 48 -- Up or Down Arrow

20

Specifications subject to change without notice.

OM-KSACN0901-01

5. Press COPY to confirm.
The mark ashes quickly ex. Copy the setting of Monday to Wednesday
Fig. 49 -- Copy
Other days can be copied by repeating steps 4 through 5. 6. Press CONFIRM.
Fig. 50 -- Confirm
7. Press BACK to revert to the weekly timer.

Fig. 51 -- Back

OM-KSACN0901-01

Specifications subject to change without notice.

21

WEEK AND DAY SETTINGS FOR WEEK 2
WEEK 2 Timer Setting 1. Press TIMER (repeatedly if need be) to select WEEK 2 2. Press CONFIRM.
Fig. 52 -- Timer and Confirm
Day of the WEEK 2 Setting 1. Press the UP or DOWN arrow to select the day of the week. 2. Press CONFIRM.
Fig. 53 -- Up or Down Arrows - Select Day - Confirm

22

Specifications subject to change without notice.

OM-KSACN0901-01

SET the ON Timer for Timer Setting 1
1. Press the UP or DOWN arrow to select the timer setting number of the day (1-8). 2. Press CONFIRM.
Fig. 54 -- Up or Down Arrows - Confirm
ex.Tuesday time scale 1
Up to 8 timer settings can be saved for each day of the week.
Fig. 55 -- Timer Settings

OM-KSACN0901-01

Specifications subject to change without notice.

23

SET the ON Timer for Timer Setting 1
1. Press the UP or DOWN arrow to select the setting time. The setting time, mode, temperature and fan speed appear on the display.
2. Press CONFIRM to enter the setting time process.

Fig. 56 -- Up or Down Arrows - Confirm

IMPORTANT: Up to 8 scheduled events can be set on a single day. Each event can be scheduled with either MODE, TEMPERATURE or FAN speed.

ex. Tuesday time scale 1

Fig. 57 -- Select Events

Operation Mode Setting
1. Press the UP or DOWN arrow to set the OPERATION mode. 2. Press CONFIRM.

Fig. 58 -- Press UP or DOWN Arrows - Select Mode - Confirm

24

Specifications subject to change without notice.

OM-KSACN0901-01

Room Temperature Setting
1. Press the UP or DOWN arrow to set the room temperature. 2. Press CONFIRM.
Fig. 59 -- Press UP or DOWN Arrow - Confirm
NOTE: This setting is unavailable in the FAN or OFF modes.
Fan Speed Setting
1. Press the UP or DOWN arrow to set the fan speed. 2. Press CONFIRM.

Fig. 60 -- UP or DOWN Arrows - Fan Speed - Confirm
NOTE: This setting is unavailable in the AUTO, DRY or OFF modes.
NOTE: Different scheduled events can be set by repeating all the steps from the "SET the ON Timer for Timer Setting 1" on page 24 through the Fan Speed Setting steps found on this page.
The weekly timer setting can be returned to the previous step by pressing BACK. The current setting is restored. The controller will not save the weekly timer settings if there is no operation within 30 seconds.

OM-KSACN0901-01

Specifications subject to change without notice.

25

Weekly Timer Operation
To start the Weekly Timer Operation 1. Press TIMER to select WEEK 2, and the timer starts automatically.

Fig. 61 -- Select Timer
To cancel the Weekly Timer Operation 1. Press POWER for 2 seconds. The wired controller must be ON to perform the function.

Fig. 62 -- Power
The TIMER mode can also be canceled by changing the timer mode using TIMER.

Fig. 63 -- Press Timer

26

Specifications subject to change without notice.

OM-KSACN0901-01

Set the DAY OFF (for WEEK 2)
1. Select WEEK 2 then press CONFIRM. See "Weekly Timer Operation" on page 26.

Fig. 64 -- Confirm
2. Press the UP or DOWN arrow to select the day of the week.

Fig. 65 -- Up or Down Arrows
3. Press DAY OFF to select day(s) off.
The mark is hidden

ex. The DAY OFF is set for Wednesday Fig. 66 -- Select DAY OFF A DAY OFF can be set for other days by repeating steps 2 through 3. 4. Press BACK to revert to the weekly timer.
NOTE: To cancel, follow the same procedures used for setup. The DAY OFF setting is canceled at the end of the set day.

OM-KSACN0901-01

Specifications subject to change without notice.

27

Copy the Setting From One Day to Another
A scheduled event, made once, can be copied to another day of the week. The scheduled events of the selected day of the week will be copied. Using the COPY mode simplifies scheduling.
1. In the weekly timer, press CONFIRM.
Fig. 67 -- Confirm
2. Press the UP or DOWN arrow to select the day to copy from.
Fig. 68 -- Up or Down Arrows
3. Press COPY; the letters CY appear on the display.

Fig. 69 -- Press Copy
4. Press the UP or DOWN arrow to select the day to copy to.

28

Specifications subject to change without notice.

OM-KSACN0901-01

5. Press COPY to confirm.
The mark flashes quickly
ex. Copy the setting of Monday to Wednesday
Fig. 70 -- Press Copy
Other days can be copied by repeating steps 4 through 5. 6. Press CONFIRM to confirm the settings.
Fig. 71 -- Confirm
7. Press BACK to revert to the weekly timer.

Fig. 72 -- Back

OM-KSACN0901-01

Specifications subject to change without notice.

29

Delete the Time Scale in One Day
1. During the weekly timer setting, press CONFIRM.
Fig. 73 -- Confirm
2. Press the UP or DOWN arrow to select the setting time you want to delete. The setting time, mode, temperature and fan speed appear on the display. The setting time, mode, temperature and fan speed can be deleted by pressing the DAY OFF.

ex. Delete the time scale 1 in Saturday
Fig. 74 -- Select Day

30

Specifications subject to change without notice.

OM-KSACN0901-01

WIRED CONTROLLER ERROR CODES

Table 1 -- Error Codes

DISPLAY ON IDU AND WIRED CONTROLLER

ERROR INFORMATION

EH 00/EH 0A EL 01 EH 02 EH 03 EC 51 EC 52 EC 53 EC 54 EC 56 EH 60 EH 61 EC 07 EH 0b EL 0C PC 00 PC 01 PC 02 PC 04 PC 08 PC 40 PC 03 EH b1 FH 0d

Indoor unit EEPROM parameter error Indoor/outdoor unit communication error Zero-crossing signal detection error Indoor fan operating outside of the normal range Outdoor unit EEPROM parameter error T3 is in open circuit or has short circuited T4 is in open circuit or has short circuited TP is in open circuit or has short circuited T2B is in open circuit or has short circuited T1 is in open circuit or has short circuited T2 is in open circuit or has short circuited Outdoor fan operating outside of the normal range Indoor PCB/Display board communication error Refrigerant leakage detection IPM malfunction or IGBT OSCP Over voltage or over low voltage protection Compressor or IPM high temp/pressure protection Inverter compressor drive error Current overload protection Comm. error between outdoor chip and compressor chip Low pressure protection Indoor board and Multi-function communication error Ionizer malfunction

*Check the indoor unit's error display and review the owner's manual if other error codes appear.

NOTE: The error displayed on the wire controller will differ from the error displayed on the unit. If the error code appears, check the Owner's and Installation Manual and Service Manual for the model number of the unit or wired controller the error is displayed on.

OM-KSACN0901-01

Specifications subject to change without notice.

31

QUERIES AND SETTINGS
CAUTION: All changes should be performed ONLY by authorized professionals.
Indoor Unit Tx Temperature Query Function
1. When the air conditioning unit is OFF, press COPY for 3 seconds to enter query mode on the wired controller.
Fig. 75 -- Copy
2. Press the UP or DOWN arrows to select.
Fig. 76 -- Up or Down Arrows
3. When the air conditioning unit is OFF and in query mode, press the UP or DOWN arrows to select SP (For Ducted Models Only).

Fig. 77 -- Up or Down Arrows
4. Press CONFIRM to adjust the static pressure value. 5. Press the UP or DOWN arrow to select the static pressure value (0~4). 6. Press CONFIRM to select the value.

32

Specifications subject to change without notice.

OM-KSACN0901-01

Auto Airflow Adjustment
1. When the air conditioning unit is OFF and in QUERY mode, press the UP or DOWN arrow to select AF (For Ducted Models Only).

Fig. 78 -- Up or Down Arrows - Select AF
2. Press CONFIRM to activate AF mode
3. The AF mode requires 3~6 minutes to complete an airflow adjustment. The unit automatically exits the mode when the adjustment completes.
4. To interrupt or exit the AF mode at anytime, press BACK or press ON/OFF or press CONFIRM. If there is no response for 30 seconds, the wired controller exits the query mode.

Fig. 79 -- Back - Confirm

OM-KSACN0901-01

Specifications subject to change without notice.

33

FOLLOW ME Mode Temperature Compensation
1. When the air conditioning unit is OFF and in QUERY mode, press the UP or DOWN arrow to select tF. The compensation temperature Range: 23°F ~ 41°F (-5°C~5°C).
Fig. 80 -- Up or Down Arrows - Select Confirm
2. Press CONFIRM to enter the temperature compensation value. 3. Press the UP or DOWN arrow to select the temperature compensation value. 4. Press CONFIRM to set compensation temperature.
Mode Customization
This setting allows the configuration of the wired controller customizing the modes available for the user as CH Heat Pump, CC Cooling Only, HH Heating Only or NA No AUTO Mode.
1. When the air conditioning unit is OFF and in query mode, press UP or DOWN arrow to select TYPE.

Fig. 81 -- Up or Down Arrows - Select Type
2. Press CONFIRM to enter TYPE, press UP or DOWN arrow to select the type (see Fig. 82).

CH: HEAT PUMP

HH: HEATING ONLY

CC: COOLING ONLY

NA: No AUTO MODE

3. Press CONFIRM.

Fig. 82 -- Press CONFIRM

34

Specifications subject to change without notice.

OM-KSACN0901-01

Set the Minimum and Maximum Temperature Values
1. When the air conditioning unit is OFF and in QUERY mode, press the UP or DOWN arrow to select tHI or tLo.

Fig. 83 -- UP or DOWN Arrows - Select or

2. Press CONFIRM to enter the setting. 3. Press the UP or DOWN arrow to select the temperature value. 4. Press CONFIRM to complete. The maximum setting temperature range is 77°F~86°F
(25°C~30°C). The minimum setting temperature range is 62.6°F~75.2°F (17°C ~24°C).

NOTE: Factory default setting on and · Maximum value setting function · Minimum value setting function

is "- -".

OM-KSACN0901-01

Specifications subject to change without notice.

35

Remote Control Mode Setting for the Wired Controller
1. When the air conditioning unit is OFF and in QUERY mode, press the UP or DOWN arrow to select rEC.
Fig. 84 -- UP or DOWN Arrow - Select rEC
2. Press CONFIRM to enter the mode setting. 3. Press UP or DOWN arrow to select the remote control mode ON or OFF (OF). 4. Press CONFIRM. NOTE: ON or OFF (OF) appears in the temperature area to indicate the remote control mode. When the selection is OFF (OF), the wire controller does not process any remote control signals.

36

Specifications subject to change without notice.

OM-KSACN0901-01

Restore Factory Settings
1. When the air conditioning unit is OFF and in QUERY mode, press the UP or DOWN arrow to select , the temperature zone appears --.
Fig. 85 -- UP or DOWN Arrows - Select
2. Press CONFIRM to enter the setting. 3. Press the UP or DOWN arrow to select ON. 4. Press CONFIRM. NOTE: All the Wired Controller's settings are restored to the factory default settings.

OM-KSACN0901-01

Specifications subject to change without notice.

37

TECHNICAL INDICATION AND REQUIREMENT
EMC and EMI comply with the CE certification requirements.

Copyright 2021 CAC/BDP D 3300 Riverwood Parkway Atlanta GA, 30339 Edition Date: 02/21

Catalog No. OM-KSACN0901-01

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Replaces: NEW


Acrobat Distiller 20.0 (Windows)

Search Any Device: