ET-22092019E03-FCC 15.407E 5G WIFI
Admin
Test Report
EP-TEC Solutions Pte Ltd XSERIES InfinityPro Interactive Flat Panel 2A8WI-XSERIES 2A8WIXSERIES xseries
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 61 Pages, 3.76MB
Document DEVICE REPORTGetApplicationAttachment.html?id=6180882Report No.: ET-22092019E03 TEST REPORT Applicant: Address of Applicant: Manufacturer/Factory: Address of Manufacturer Product Name: Model No.: Trade Mark: FCC ID: Applicable standards: Date of Test: Date of report issued: Test Result : EP-TEC Solutions Pte Ltd 2 Sims Close #05-07 Gemini @ Sims Singapore 387298 EP-TEC Solutions Pte Ltd 2 Sims Close #05-07 Gemini @ Sims Singapore 387298 InfinityPro Interactive Flat Panel X Series, V Series, E Series InfinityPro 2A8WI-XSERIES FCC CFR Title 47 Part 15 Subpart E Section 15.407 Sep.23, 2022- Oct.14, 2022 Oct.18, 2022 PASS * Remark: * In the configuration tested, the EUT complied with the standards specified above. The results shown in this test report refer only to the sample(s) tested , this test report cannot be reproduced, except in full without prior written permission of the company. The report would be invalid without specific stamp of test institute and the signatures of compiler and approver Prepared By Shenzhen ETR Standard Technology Co., Ltd. Address: No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Compiled by: Reviewed by: Approved by: Project Engineer Project Manager Authorized Signature This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen ETR Standard Technology Co., Ltd. - Page 2 of 61 - Report No.: ET-22092019E03 Report No. ET-22092019E03 Report Revision History Description Original Issue Date Oct.18, 2022 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 3 of 61 - Contents Report No.: ET-22092019E03 Page 1 TEST SUMMARY ..................................................................................................................................... 4 1.1 MEASUREMENT UNCERTAINTY ............................................................................................................ 4 2 GENERAL INFORMATION ...................................................................................................................... 5 2.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 5 2.2 TEST MODE ........................................................................................................................................ 7 2.3 DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 8 2.4 DEVIATION FROM STANDARDS ............................................................................................................. 8 2.5 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................... 8 2.6 TEST FACILITY.................................................................................................................................... 8 2.7 TEST LOCATION ................................................................................................................................. 8 2.8 ADDITIONAL INSTRUCTIONS................................................................................................................. 8 3 TEST INSTRUMENTS LIST ..................................................................................................................... 9 4 TEST RESULTS AND MEASUREMENT DATA.................................................................................... 10 4.1 ANTENNA REQUIREMENT ................................................................................................................... 10 4.2 CONDUCTED EMISSIONS ................................................................................................................... 11 4.3 CONDUCTED PEAK OUTPUT POWER .................................................................................................. 14 4.4 CHANNEL BANDWIDTH ...................................................................................................................... 16 4.5 POWER SPECTRAL DENSITY ............................................................................................................. 24 4.6 BAND EDGE ...................................................................................................................................... 32 4.6.1 Conducted test Method.............................................................................................................. 32 4.7 SPURIOUS EMISSION......................................................................................................................... 39 4.7.1 Radiated Emission Method ........................................................................................................ 39 4.7.2 Conducted Emission Method ..................................................................................................... 48 4.8 FREQUENCY STABILITY ..................................................................................................................... 55 5 TEST SETUP PHOTO ............................................................................................................................ 61 6 EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 61 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 4 of 61 - Report No.: ET-22092019E03 1 Test Summary Test Item Section in CFR 47 Antenna requirement 15.203 AC Power Line Conducted Emission 15.207 Conducted Output Power 15.407 (a)(1)/(a)(3) 26dB Bandwidth and 99% Occupied Bandwidth 15.407 (a)(12) 6dB Bandwidth 15.407 (e) Power Spectral Density 15.407(a)(1)/(a)(3) Band Edge 15.407(b)(1)/(b)(4) Spurious Emission 15.205/15.209 15.407(b)(1)/(b)(4)/(b)(8) Frequency Stability 15.407(g) Remarks 1. Pass: The EUT complies with the essential requirements in the standard. 2. Test according to ANSI C63.10:2013. Result Pass Pass Pass Pass Pass Pass Pass Pass Pass Test by / Carr Kang Yvan Fan Yvan Fan Yvan Fan Yvan Fan Yvan Fan Qiao Li Yvan Fan 1.1 Measurement Uncertainty Test Item Measurement Uncertainty Notes Occupied Channel Bandwidth ±0.55% (1) RF output power, conducted ±0.99dB (1) Power Spectral Density, conducted ±0.61dB (1) Unwanted Emissions, conducted ±0.64dB (1) AC Power Line Conducted Emission ± 3.02dB (1) Radiated emissions 9K-30MHz ±3.98dB (1) Radiated emissions 30M- 1GHz ±4.30dB (1) Radiated emissions 1GHz-18GHz ±4.35dB (1) Radiated emissions 18GHz-40GHz ±4.59 dB (1) Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%. Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 5 of 61 - Report No.: ET-22092019E03 2 General Information 2.1 General Description of EUT Product Name: Model No.: InfinityPro Interactive Flat Panel X Series, V Series, E Series Difference of model(s) All the models are the same circuit and RF module, except the appearance color. Test Model: Hardware Version: Software Version: Sample(s) Status: Operation Frequency: Channel numbers: Channel bandwidth: Data Rate Modulation technology: Antenna Type: X Series N/A N/A Engineer sample 5180-5240MHz for 802.11a/n(HT20)/ac20; 5190-5230MHz for 802.11n(HT40)/ac40; 5210MHz for 802.11 ac80; 5745-5825 MHz for 802.11a/n(HT20)/ac20; 5755-5795 MHz for 802.11n(HT40)/ac40; 5775MHz for 802.11 ac80; 4 channels for 802.11a/n20/ac20 in the 5180-5240MHz band; 2 channels for 802.11 n40/ac40 in the 5190-5230MHz band ; 1 channels for 802.11 ac80 in the 5210MHz band ; 5 channels for 802.11a/n20/ac20 in the 5745-5825MHz band ; 2 channels for 802.11 n40/ac40 in the 5755-5795MHz band ; 1 channels for 802.11 ac80 in the 5775MHz band 802.11a/802.11n(HT20)/ 802.11ac(HT20): 20MHz 802.11n(HT40)/ 802.11ac(HT40) : 40MHz 802.11ac(HT80) : 80MHz 802.11a: 6,9,12,18,24,36,48,54Mbps; 802.11n(HT20/HT40):MCS0-MCS15; 802.11ac(VHT/20/40/80):NSS1, MCS0-MCS9 Orthogonal Frequency Division Multiplexing (OFDM) with BPSK/QPSK/16QAM/64QAM/256QAM External antenna Antenna gain: 2.76dBi(Declare by applicant) Power supply: AC 100-240V 50/60Hz Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 6 of 61 - Report No.: ET-22092019E03 Channel 36 44 Channel 149 157 165 Frequency 5180MHz 5220MHz Frequency 5745MHz 5785MHz 5825MHz Operation Frequency each of channel Channel Frequency Channel Frequency 38 5190MHz 40 5200MHz 46 5230MHz 48 5240MHz Channel Frequency Channel Frequency 151 5755MHz 153 5765MHz 159 5795MHz 161 5805MHz / Channel 42 / Channel 155 / Frequency 5210MHz / Frequency 5775MHz / Note: In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the middle frequency, and the highest frequency of channel were selected to perform the test, and the selected channel see below: Test channel Lowest channel 802.11 a /n(HT20)/ac(HT20) 5180 Frequency (MHz) 802.11 n(HT40)/ac(HT40) 5190 802.11ac(HT80) 5210 Middle channel 5200 Highest channel 5240 5230 Test channel Lowest channel Middle channel Highest channel 802.11 a /n(HT20)/ac(HT20) 5745 5785 5825 Frequency (MHz) 802.11 n(HT40)/ac(HT40) 5755 5795 802.11ac(HT80) 5775 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 7 of 61 - Report No.: ET-22092019E03 2.2 Test mode Transmitting mode Keep the EUT in continuously transmitting mode(or with a duty cycle 98%) Remark: During the test, the test voltage was tuned from 85% to 115% of the nominal rated supply voltage, and found that the worst case was under the nominal rated supply condition. So the report just shows that condition's data. We have verified the construction and function in typical operation. All the test modes were carried out with the EUT in transmitting operation, which was shown in this test report and defined as follows: Pretest Mode Mode 1 Mode 2 Mode 3 Mode 4 Mode 5 Description 802.11a / n 20 CH36/ CH40/ CH 48 802.11a /n 20 CH149/ CH157/ CH 165 802.11n 40 CH38/ CH 46 802.11n 40 CH 151 / CH 159 802.11 ac80 CH 42/CH 155 802.11a / n 20 CH36/ CH40/ CH 48 802.11a /n 20 CH149/ CH157/ CH 165 Link Mode Final Test Mode Mode 5 Conducted Emission Description Link Mode Final Test Mode Mode 1 Mode 2 Mode 3 Mode 4 Note: For Radiated Emission Description 802.11a / n 20 CH36/ CH40/ CH 48 802.11a /n 20 CH149/ CH157/ CH 165 802.11n 40 CH38/ CH 46 802.11n 40 CH 151 / CH 159 802.11 ac80 CH 42/CH 155 802.11a / n 20 CH36/ CH40/ CH 48 802.11a /n 20 CH149/ CH157/ CH 165 (1) The measurements are performed at all Bit Rate of Transmitter, the worst data was reported. Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 8 of 61 - Report No.: ET-22092019E03 2.3 Description of Support Units No. Description Manufacturer Model / / / / 2.4 Deviation from Standards None. 2.5 Abnormalities from Standard Conditions None. 2.6 Test Facility Test laboratory: Shenzhen ETR Standard Technology Co., Ltd. CNAS Registration Number: L11864 A2LA Certificate Number: 6640.01 FCC Designation Number: FCC Test Firm Registration: CN1326 183064 Serial Number / 2.7 Test Location All tests were performed at: Laboratory location: No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Telephone: +86 755 85259392 2.8 Additional Instructions Test Software RFTestTool.apk Power level setup Default Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 9 of 61 - Report No.: ET-22092019E03 3 Test Instruments list Conducted Emission Item Equipment name 1 EMI Test Receiver 2 amplifier 3 Artificial power network 4 Artificial power network 5 10dB attenuator 6 Cable 4 7 Absorbing Clamp Manufacturer Rohde&schwarz EMtrace schwarabeck ETS HUBER+SUHNER HUBER SUNNER schwarabeck Model ESCI3 RP01A NSLK8127 3186/2NM 10dB 3M MDS21 Serial No. 100605 50117 8127483 1132 / / D69250 Calibration date 2022.3.09 2022.3.09 2022.3.09 2022.3.09 2022.3.09 2022.3.09 2022.3.11 Due date 2023.3.08 2023.3.08 2023.3.08 2023.3.08 2023.3.08 2022.3.08 2023.3.10 Radiated Emission &RF Conducted test: Item Equipment name Manufacturer 1 EMI Test Receiver 2 Broadband antenna 3 Horn antenna 4 amplifier 5 amplifier 6 Spectrum analyzer 7 Power detector box 8 Signal generator 9 Spectrum analyzer 10 amplifier 11 Horn antenna 12 Loop antenna 13 Cable 6 14 Cable7 15 Cable8 Rohde&schwarz schwarabeck schwarabeck EMtrace Space-Dtronics KEYSIGHT MWRFtest Agilent Rohde&schwarz Aeroflex Com-Power schwarabeck HUBER SUNNER HUBER SUNNER HUBER SUNNER Model ESPI7 VULB9168 BBHA9120D RP01A EWLAN0118G-P40 N9020A MW100-PSB N5182A FSV40 DLE-161 SAS-574 FMZB 1519 B 0.5M 2.0M 6.0M Serial No. 100605 1064 9120D-1145 50117 19113001 MY55370280 MW201020JYT MY49060455 100363 097 588 1519 / / / Calibration date 2022.3.09 2022.3.11 2022.3.11 2022.3.09 2022.3.09 2022.3.09 2021.11.19 2021.11.19 2022.3.09 2022.3.09 2022.3.11 2022.3.11 2022.3.09 2022.3.09 2022.3.09 Due date 2023.3.08 2024.3.10 2024.3.10 2023.3.08 2023.3.08 2023.3.08 2022.11.18 2022.11.18 2023.3.08 2023.3.08 2024.3.10 2024.3.10 2023.3.08 2023.3.08 2023.3.08 Note: the calibration interval of the above test instruments is 12 or 24 months and the calibrations are traceable to international system unit (SI). Software Name RF test software Conducted test software Radiated test software Manufacturer MWRFtest EZ-EMC EZ-EMC Model MTS 8310 Farad Farad Version V2.0.0.0 Ver.EMC-CON 3A1.1 Ver.FA-03A2 RE Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 10 of 61 Report No.: ET-22092019E03 - 4 Test results and Measurement Data 4.1 Antenna requirement Standard requirement: FCC Part15 C Section 15.203 15.203 requirement: An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited. E.U.T Antenna: The antennas are External antenna, the best case gain of the antennas are 2.76dBi, reference to the appendix II for details Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 11 of 61 Report No.: ET-22092019E03 - 4.2 Conducted Emissions Test Requirement: Test Method: Test Frequency Range: Class / Severity: Receiver setup: Limit: Test setup: FCC Part15 C Section 15.207 ANSI C63.10:2013 150KHz to 30MHz Class B RBW=9KHz, VBW=30KHz, Sweep time=auto Frequency range (MHz) Limit (dBuV) Quasi-peak Average 0.15-0.5 66 to 56* 56 to 46* 0.5-5 56 46 5-30 60 50 * Decreases with the logarithm of the frequency. Test procedure: Test Instruments: Test mode: Test environment: Test voltage: Test results: 1. The E.U.T and simulators are connected to the main power through a line impedance stabilization network (L.I.S.N.). This provides a 50ohm/50uH coupling impedance for the measuring equipment. 2. The peripheral devices are also connected to the main power through a LISN that provides a 50ohm/50uH coupling impedance with 50ohm termination. (Please refer to the block diagram of the test setup and photographs). 3. Both sides of A.C. line are checked for maximum conducted interference. In order to find the maximum emission, the relative positions of equipment and all of the interface cables must be changed according to ANSI C63.10:2013 on conducted measurement. Refer to section 3.0 for details Refer to section 2.2 for details Temp.: 24.7C Humid.: 50% Press.: 1012mbar AC 120V, 60Hz Pass Remark: Both high voltage and low voltage have been tested, and the report only shows the worst case data with AC 120V/60Hz. Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Measurement data Line: - Page 12 of 61 Report No.: ET-22092019E03 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Neutral: - Page 13 of 61 Report No.: ET-22092019E03 Notes: 1. An initial pre-scan was performed on the line and neutral lines with peak detector. 2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission. 3. Final Level =Receiver Read level + LISN Factor + Cable Loss 4. If the average limit is met when using a quasi-peak detector receiver, the EUT shall be deemed to meet both limits and measurement with the average detector receiver is unnecessary. Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 14 of 61 Report No.: ET-22092019E03 - 4.3 Conducted Peak Output Power Test Requirement: Test Method: Limit: Test setup: FCC Part15 E Section 15.407 (a)(1)/(a)(3) ANSI C63.10:2013 and KDB 789033 D02 General U-NII Test Procedures New Rules v02r01 5150-5250MHz : 250mW 5725~5850MHz : 1W Test Instruments: Test mode: Test results: Measurement Data Test Channel Frequency (MHz) CH36 CH40 CH48 CH36 CH40 CH48 CH36 CH40 CH48 CH38 CH46 CH38 CH46 CH42 5180 5200 5240 5180 5200 5240 5180 5200 5240 5190 5230 5190 5230 5210 Refer to section 3.0 for details Refer to section 2.2 for details Pass Maximum output power (dBm) TX 802.11a Mode 13.93 13.56 13.73 TX 802.11 n20 Mode 13.77 13.57 13.68 TX 802.11 ac20 Mode 13.12 12.76 13.03 TX 802.11 n40 Mode 12.58 12.47 TX 802.11 ac40 Mode 12.66 12.47 TX 802.11 ac80 Mode 11.77 LIMIT dBm 23.98 23.98 23.98 23.98 23.98 23.98 23.98 23.98 23.98 23.98 23.98 23.98 23.98 23.98 Result Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 15 of 61 Report No.: ET-22092019E03 - Test Channel Frequency (MHz) CH149 CH157 CH165 CH149 CH157 CH165 CH149 CH157 CH165 CH151 CH159 CH151 CH159 CH155 5745 5785 5825 5745 5785 5825 5745 5785 5825 5755 5795 5755 5795 5775 Maximum output power. (dBm) TX 802.11a Mode 12.30 12.58 12.84 TX 802.11 n20 Mode 11.73 11.96 12.10 TX 802.11 ac20 Mode 11.58 11.89 12.16 TX 802.11 n40 Mode 11.59 11.80 TX 802.11 ac40 Mode 11.63 11.78 TX 802.11 ac80 Mode 12.34 LIMIT dBm 30 30 30 30 30 30 30 30 30 30 30 30 30 30 Result Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 16 of 61 Report No.: ET-22092019E03 - 4.4 Channel Bandwidth Test Requirement: Test Method: Limit: Test setup: FCC Part15 E Section 15.407(a)(12)&15.407(e) ANSI C63.10:2013 and KDB 789033 D02 General U-NII Test Procedures New Rules v02r01 Measurements in the 5.725-5.85 GHz band, the minimum bandwidth 6 dB bandwidth of U-NII devices shall be at least 500KHz. Measurements in the 5.15-5.25 GHz, 5.25-5.35 GHz, and the 5.47-5.725 GHz bands are made over a bandwidth of 1 MHz or the 26 dB emission bandwidth of the device, whichever is less. A narrower resolution bandwidth can be used, provided that the measured power is integrated over the full reference bandwidth. Test Instruments: Test mode: Test results: Measurement Data 5180-5240MHz Test CH Lowest Middle Highest 802.11a 23.51 24.26 22.98 Refer to section 3.0 for details Refer to section 2.2 for details Pass -26dB Channel Bandwidth (MHz) 802.11n (HT20) 802.11ac (HT20) 802.11n (HT40) 802.11ac (HT40) 24.58 23.81 44.20 43.38 24.12 24.64 -- -- 24.33 24.82 44.13 44.56 802.11ac (HT80) -82.41 -- Result Pass Test CH Lowest Middle Highest 802.11a 16.843 16.886 16.850 99% Occupy Bandwidth (MHz) 802.11n (HT20) 802.11ac (HT20) 802.11n (HT40) 802.11ac (HT40) 17.978 17.951 36.245 36.279 17.979 17.968 -- -- 17.934 17.928 36.264 36.266 802.11ac (HT80) -75.193 -- Result Pass Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 17 of 61 Report No.: ET-22092019E03 - (802.11a) plot on channel 36 Test plot (802.11 n20) plot on channel 36 (802.11a) plot on channel 40 (802.11 n20) plot on channel 40 (802.11a) plot on channel 48 (802.11 n20) plot on channel 48 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 18 of 61 Report No.: ET-22092019E03 - (802.11ac20) plot on channel 36 Test plot (802.11 n40) plot on channel 38 (802.11ac20) plot on channel 40 (802.11 n40) plot on channel 46 (802.11ac20) plot on channel 48 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 19 of 61 Report No.: ET-22092019E03 - (802.11ac40) plot on channel 38 Test plot (802.11ac80) plot on channel 42 (802.11ac40) plot on channel 46 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 20 of 61 Report No.: ET-22092019E03 - 5745-5825MHz -6dB Channel Bandwidth (MHz) Test CH 802.11a 802.11n (HT20) 802.11ac (HT20) 802.11n (HT40) 802.11ac (HT40) Lowest 16.32 17.56 17.57 36.02 36.29 Middle 16.32 17.58 17.58 -- -- Highest 16.31 17.57 17.56 36.33 36.30 Remark: "---"is not applicable 802.11ac (HT80) -75.11 -- Limit (KHz) >500 Result Pass Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 21 of 61 Report No.: ET-22092019E03 - (802.11a) plot on channel 149 Test plot (802.11 n20) plot on channel 149 (802.11a) plot on channel 157 (802.11 n20) plot on channel 157 (802.11a) plot on channel 165 (802.11 n20) plot on channel 165 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 22 of 61 Report No.: ET-22092019E03 - (802.11ac20) plot on channel 149 Test plot (802.11 n40) plot on channel 151 (802.11ac20) plot on channel 157 (802.11 n40) plot on channel 159 (802.11ac20) plot on channel 165 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 23 of 61 Report No.: ET-22092019E03 - (802.11 ac40) plot on channel 151 Test plot (802.11 ac80) plot on channel 155 (802.11 ac40) plot on channel 159 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 24 of 61 Report No.: ET-22092019E03 - 4.5 Power Spectral Density Test Requirement: Test Method: Limit: Test setup: FCC Part15 E Section 15.407(a)(1)/ (a)(3) ANSI C63.10:2013 and KDB 789033 D02 General U-NII Test Procedures New Rules v02r01 Frequency band (MHz) 5150-5250 5250-5350 5470-5725 725-5850 Limit 17dBm/1MHz for master device 11dBm/1MHz for client device 11dBm/1MHz for client device 11dBm/1MHz for client device 30dBm/500kHz Test Instruments: Test mode: Test results: Measurement Data 5180-5240MHz Mode 802.11 a 802.11 n20 802.11 ac20 802.11 n40 802.11 ac40 802.11 ac80 Refer to section 3.0 for details Refer to section 2.2 for details Pass Frequency 5180 MHz 5200 MHz 5240 MHz 5180 MHz 5200 MHz 5240 MHz 5180 MHz 5200 MHz 5240 MHz 5190 MHz 5230 MHz 5190 MHz 5230 MHz 5210 MHz Measured Power Density (dBm/MHz) 5.938 5.404 5.686 5.195 5.098 5.106 4.56 4.413 4.526 1.877 1.112 1.537 1.288 -1.624 Limit (dBm/MHz) 11 11 11 11 11 11 11 11 11 11 11 11 11 11 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 25 of 61 Report No.: ET-22092019E03 - (802.11a) PSD plot on channel 36 (802.11n20) PSD plot on channel 36 (802.11a) PSD plot on channel 40 (802.11n20) PSD plot on channel 40 (802.11a) PSD plot on channel 48 (802.11n20) PSD plot on channel 48 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 26 of 61 Report No.: ET-22092019E03 - (802.11ac20) PSD plot on channel 36 (802.11n40) PSD plot on channel 38 (802.11ac20) PSD plot on channel 40 (802.11n40) PSD plot on channel 46 (802.11ac20) PSD plot on channel 48 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 27 of 61 Report No.: ET-22092019E03 - (802.11ac40) PSD plot on channel 38 (802.11ac80) PSD plot on channel 42 (802.11ac40) PSD plot on channel 46 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 28 of 61 Report No.: ET-22092019E03 - Mode 802.11 a 802.11 n20 802.11 ac20 802.11 n40 802.11 ac40 802.11 ac80 Frequency 5745 MHz 5785 MHz 5825 MHz 5745 MHz 5785 MHz 5825 MHz 5745 MHz 5785 MHz 5825 MHz 5755 MHz 5795 MHz 5755 MHz 5795 MHz 5775 MHz Measured Power Density (dBm/510KHz) 1.271 0.829 0.473 -0.266 -0.084 -0.027 -0.499 -0.282 0.0250 -2.509 -2.910 -2.812 -3.244 -5.405 Measured Power Density (dBm/500KHz) 1.185 0.743 0.387 -0.352 -0.170 -0.113 -0.585 -0.368 -0.061 -2.595 -2.996 -2.898 -3.330 -5.491 Limit (dBm/MHz) 30 30 30 30 30 30 30 30 30 30 30 30 30 30 Note: If the measurement is X dBm/510kHz, thus X dBm/510kHz = (10X/10)*(500 / 510) dBm/500kHz Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 29 of 61 Report No.: ET-22092019E03 - (802.11a) PSD plot on channel 149 (802.11n20) PSD plot on channel 149 (802.11a) PSD plot on channel 157 (802.11n20) PSD plot on channel 157 (802.11a) PSD plot on channel 165 (802.11n20) PSD plot on channel 165 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 30 of 61 Report No.: ET-22092019E03 - (802.11ac20) PSD plot on channel 149 (802.11n40) PSD plot on channel 151 (802.11ac20) PSD plot on channel 157 (802.11n40) PSD plot on channel 159 (802.11ac20) PSD plot on channel 165 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 31 of 61 Report No.: ET-22092019E03 - (802.11ac40) PSD plot on channel 151 (802.11ac80) PSD plot on channel 155 (802.11ac40) PSD plot on channel 159 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 32 of 61 Report No.: ET-22092019E03 - 4.6 Band edge 4.6.1 Conducted test Method Test Requirement: Test Method: Limit: Test setup: FCC Part15 C Section 15.209 and 15.205 ANSI C63.10: 2013 All emissions shall be limited to a level of -27 dBm/MHz at 75 MHz or more above or below the band edge increasing linearly to 10 dBm/MHz at 25 MHz above or below the band edge, and from 25 MHz above or below the band edge increasing linearly to a level of 15.6 dBm/MHz at 5 MHz above or below the band edge, and from 5 MHz above or below the band edge increasing linearly to a level of 27 dBm/MHz at the band edge. Test Procedure: Test Instruments: Test mode: Test results: Remarks:/ 1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal from an external generator. 2. Position the EUT without connection to measurement instrument. Turn on the EUT and connect its antenna terminal to measurement instrument via a low loss cable. Then set it to any one measured frequency within its operating range, and make sure the instrument is operated in its linear range. 3. Set RBW of spectrum analyzer to 1 MHz with a convenient frequency span. 4. Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the graph with marking the highest point and edge frequency. 5. Repeat above procedures until all measured frequencies were complete.. Refer to section 3.0 for details Refer to section 2.2 for details Pass Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 33 of 61 Report No.: ET-22092019E03 - 5.180~5.240 GHz (802.11a) Band Edge, Left Side (802.11n20) Band Edge, Left Side (802.11a) Band Edge, Right Side (802.11n20) Band Edge, Right Side Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 34 of 61 Report No.: ET-22092019E03 - 5.180~5.240 GHz (802.11ac20) Band Edge, Left Side (802.11n40) Band Edge, Left Side (802.11ac20) Band Edge, Right Side (802.11n40) Band Edge, Right Side Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 35 of 61 Report No.: ET-22092019E03 - 5.180~5.240 GHz (802.11ac40) Band Edge, Left Side (802.11ac80) Band Edge (802.11ac40) Band Edge, Right Side Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 36 of 61 Report No.: ET-22092019E03 - 5.745~5.825 GHz (802.11a) Band Edge, Left Side (802.11n20) Band Edge, Left Side (802.11a) Band Edge, Right Side (802.11n20) Band Edge, Right Side Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 37 of 61 Report No.: ET-22092019E03 - 5.745~5.825 GHz (802.11ac20) Band Edge, Left Side (802.11n40) Band Edge, Left Side (802.11ac20) Band Edge, Right Side (802.11n40) Band Edge, Right Side Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 38 of 61 Report No.: ET-22092019E03 - 5.745~5.825 GHz (802.11ac40) Band Edge, Left Side (802.11ac80) Band Edge (802.11ac40) Band Edge, Right Side Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 39 of 61 Report No.: ET-22092019E03 - 4.7 Spurious Emission 4.7.1 Radiated Emission Method Test Requirement: FCC Part15 C Section 15.209, Part 15E Section 15.407(b)(4) Test Method: ANSI C63.10:2013 Test Frequency Range: 9kHz to 40GHz Test site: Measurement Distance: 3m Receiver setup: Limit: Frequency 9kHz-150KHz 150kHz-30MHz 30MHz-1GHz Above 1GHz Detector Quasi-peak Quasi-peak Quasi-peak Peak AV RBW 200Hz 9kHz 120KHz 1MHz 1MHz Frequency Limit (uV/m) VBW 1kHz 30kHz 300KHz 3MHz 3MHz Value Value Quasi-peak Value Quasi-peak Value Quasi-peak Value Peak Value Average Value Measurement Distance 0.009MHz-0.490MHz 2400/F(KHz) QP 0.490MHz-1.705MHz 24000/F(KHz) QP 1.705MHz-30MHz 30 QP 30MHz-88MHz 100 QP 88MHz-216MHz 150 QP 216MHz-960MHz 200 QP 960MHz-1GHz 500 QP 300m 300m 30m 3m Test setup: Frequency Above 1GHz Limit (dBm/MHz) -27.0 For radiated emissions from 9kHz to 30MHz Remark Peak Value For radiated emissions from 30MHz to1GHz Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 40 of 61 Report No.: ET-22092019E03 - For radiated emissions above 1GHz Test Procedure: 1. The EUT was placed on the top of a rotating table (0.8m for below 1GHz and 1.5 meters for above 1GHz) above the ground at a 3 meter camber. The table was rotated 360 degrees to determine the position of the highest radiation. 2. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower. 3. The antenna height is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement. 4. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters and the rota table was turned from 0 degrees to 360 degrees to find the maximum reading. 5. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode. 6. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that did not have 10dB margin would be re-tested one by one using peak, quasi-peak or average Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 41 of 61 Report No.: ET-22092019E03 - method as specified and then reported in a data sheet. 7. The radiation measurements are performed in X, Y, Z axis positioning. And found the X axis positioning which it is worse case, only the test worst case mode is recorded in the report. Test Instruments: Refer to section 3.0 for details Test mode: Refer to section 2.2 for details Test environment: Test voltage: Temp.: 24.9 C DC 5V from adapter Humid.: 51% Press.: 1012mbar Test results: Pass Remarks: 1. All antennas was tested, only show the worst case 802.11n20 mode test data. 2. Pre-scan all kind of the place mode (X-axis, Y-axis, Z-axis), and found the Y-axis which it is worse case. 3. According to KDB 789033 D02v02r01 section G) 1) d),for measurements above 1000 MHz @3m distance, the limit of field strength is computed as follows: E[dBuV/m] = EIRP[dBm] + 95.2; For example, if EIRP = -27dBm E[dBuV/m] = -27 + 95.2 = 68.2dBuV/m. Measurement Data: 9 kHz ~ 30 MHz The emission from 9 kHz to 30MHz was pre-tested and found the result was 20dB lower than the limit, and according to 15.31(o) & RSS-Gen 6.13, the test result no need to reported. Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 42 of 61 Report No.: ET-22092019E03 - Below 1GHz Temperature Pressure Test Mode 25.4 1010 hPa 5.2G TX- 802.11n20 Horizontal: Relative Humidity 47% Test Voltage AC 120V Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China Vertical: - Page 43 of 61 Report No.: ET-22092019E03 Remarks: 1. Final Level =Receiver Read level + Antenna Factor + Cable Loss Preamplifier Factor 2. The emission levels of other frequencies are very lower than the limit and not show in test report. 3. The test data shows only the worst case 802.11n20 mode Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 44 of 61 Report No.: ET-22092019E03 - Above 1GHz: Temperature Pressure Test Mode 25.4 1010 hPa 5.2G TX- 802.11n20 Relative Humidity 47% Test Voltage AC 120V Polar (H/V) Frequency (MHz) Meter Read n g (dBuV) V 10360.00 46.11 V 10360.00 36.79 V 15540.00 43.41 V 15540.00 34.04 V 20720.00 51.92 V 20720.00 42.54 V 25900.00 49.72 V 25900.00 39.96 H 10360.00 46.04 H 10360.00 35.51 H 15540.00 42.49 H 15540.00 31.75 H 20720.00 54.00 H 20720.00 43.38 H 25900.00 50.67 H 25900.00 40.00 Preamplifie r 802.11n20 Cable Antenna Loss Factor Emission Level (dB) (dB) (dB) (dBuV/m) 46.20 46.20 46.30 46.30 57.40 57.40 56.50 56.50 46.20 46.20 46.30 46.30 57.40 57.40 56.50 56.50 Low Channel:5180MHz 8.27 38.50 46.68 8.27 38.50 37.36 10.35 38.70 46.16 10.35 38.70 36.79 11.93 37.80 44.25 11.93 37.80 34.87 13.45 39.70 46.37 13.45 39.70 36.61 8.27 38.50 46.61 8.27 38.50 36.08 10.35 38.70 45.24 10.35 38.70 34.50 11.93 37.80 46.33 11.93 37.80 35.71 13.45 39.70 47.32 13.45 39.70 36.65 Limits (dBuV/m) 68.20 54.00 74.00 54.00 68.20 54.00 68.20 54.00 68.20 54.00 74.00 54.00 68.20 54.00 68.20 54.00 Margin (dB) -21.52 -16.64 -27.84 -17.21 -23.95 -19.13 -21.83 -17.39 -21.59 -17.92 -28.76 -19.50 -21.87 -18.29 -20.88 -17.35 Detect or Type PK AV PK AV PK AV PK AV PK AV PK AV PK AV PK AV Polar (H/V) Frequency (MHz) Meter Reading (dBuV) V 10400.00 50.14 V 10400.00 41.15 V 15600.00 49.60 V 15600.00 39.84 V 20800.00 60.63 V 20800.00 49.90 V 26000.00 55.25 V 26000.00 46.55 H 10400.00 52.07 H 10400.00 41.45 H 15600.00 49.58 H 15600.00 39.84 H 20800.00 59.46 H 20800.00 47.58 H 26000.00 54.93 H 26000.00 45.66 Pre- Cable Antenna Emission amplifier Loss Factor Level (dB) (dB) (dB) (dBuV/m) Middle Channel:5200MHz 46.2 8.27 38.5 50.71 46.20 8.27 38.50 41.72 46.30 10.35 38.40 52.05 46.30 10.35 38.40 42.29 57.40 11.93 37.80 52.96 57.40 11.93 37.80 42.23 56.50 13.45 39.80 52.00 56.50 13.45 39.80 43.30 46.20 8.27 38.50 52.64 46.20 8.27 38.50 42.02 46.30 10.35 38.40 52.03 46.30 10.35 38.40 42.29 57.40 11.93 37.80 51.79 57.40 11.93 37.80 39.91 56.50 13.45 39.80 51.68 56.50 13.45 39.80 42.41 Limits (dBuV/m) 68.20 54.00 74.00 54.00 68.20 54.00 68.20 54.00 68.20 54.00 74.00 54.00 68.20 54.00 68.20 54.00 Margin Detect or (dB) Type -17.49 PK -12.28 AV -21.95 PK -11.71 AV -15.24 PK -11.77 AV -16.20 PK -10.70 AV -15.56 PK -11.98 AV -21.97 PK -11.71 AV -16.41 PK -14.09 AV -16.52 PK -11.59 AV Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 45 of 61 Report No.: ET-22092019E03 - Polar (H/V) V V V V V V V V H H H H H H H H Frequency (MHz) 10480.00 10480.00 15720.00 15720.00 20960.00 20960.00 26200.00 26200.00 10480.00 10480.00 15720.00 15720.00 20960.00 20960.00 26200.00 26200.00 Meter Reading (dBuV) 47.45 36.75 44.85 34.32 55.66 46.49 51.37 41.28 47.71 36.75 45.20 34.43 55.85 46.38 51.05 40.62 Pre- Cable Antenna Emission amplifier Loss Factor Level (dB) 46.20 46.20 46.30 46.30 57.40 57.40 56.50 56.50 46.20 46.20 46.30 46.30 57.40 57.40 56.50 56.50 (dB) (dB) (dBuV/m) High Channel:5240MHz 8.27 38.60 48.12 8.27 38.60 37.42 10.35 38.40 47.30 10.35 38.40 36.77 11.93 37.50 47.69 11.93 37.50 38.52 13.45 40.10 48.42 13.45 40.10 38.33 8.27 38.60 48.38 8.27 38.60 37.42 10.35 38.40 47.65 10.35 38.40 36.88 11.93 37.50 47.88 11.93 37.50 38.41 13.45 40.10 48.10 13.45 40.10 37.67 Limits (dBuV/m) 68.20 54.00 74.00 54.00 68.20 54.00 68.20 54.00 68.20 54.00 74.00 54.00 68.20 54.00 68.20 54.00 Margin (dB) -20.08 -16.58 -26.70 -17.23 -20.51 -15.48 -19.78 -15.67 -19.82 -16.58 -26.35 -17.12 -20.32 -15.59 -20.10 -16.33 Detect or Type PK AV PK AV PK AV PK AV PK AV PK AV PK AV PK AV Remark: 1. Emission Level = Meter Reading + Antenna Factor + Cable Loss Pre-amplifier, Margin= Emission Level - Limit 2. If peak below the average limit, the average emission was no test. 3. The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible value has no need to be reported. 4. The worst mode is 802.11n20, only the worst data is recorded. Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 46 of 61 Report No.: ET-22092019E03 - Temperature Pressure Test Mode 25.4 1010 hPa 5.8G TX- 802.11n20 Relative Humidity 47% Test Voltage AC 120V Polar Frequency (H/V) (MHz) V 11490.00 V 11490.00 V 17235.00 V 17235.00 V 22980.00 V 22980.00 V 28725.00 V 28725.00 H 11490.00 H 11490.00 H 17235.00 H 17235.00 H 22980.00 H 22980.00 H 28725.00 H 28725.00 Meter Readi g (dBuV) 49.44 40.37 46.74 38.63 56.44 47.55 52.89 43.45 49.96 40.17 47.87 39.10 58.89 47.30 55.08 44.15 Preamplifier 802.11n20 Cable Antenn Loss Factor Emission Level (dB) (dB) (dB) (dBuV/m) Low Channel:5745MHz 46.10 8.77 39.10 46.10 8.77 39.10 47.60 11.10 38.70 47.60 11.10 38.70 56.90 12.73 37.70 56.90 12.73 37.70 55.60 14.25 40.30 55.60 14.25 40.30 46.10 8.77 39.10 46.10 8.77 39.10 47.60 11.10 38.70 47.60 11.10 38.70 56.90 12.73 37.70 56.90 12.73 37.70 55.60 14.25 40.30 55.60 14.25 40.30 51.21 42.14 48.94 40.83 49.97 41.08 51.84 42.40 51.73 41.94 50.07 41.30 52.42 40.83 54.03 43.10 Limits (dBuV/m) 74.00 54.00 68.20 54.00 74.00 54.00 68.20 54.00 74.00 54.00 68.20 54.00 74.00 54.00 68.20 54.00 Margin (dB) -22.79 -11.86 -19.26 -13.17 -24.03 -12.92 -16.36 -11.60 -22.27 -12.06 -18.13 -12.70 -21.58 -13.17 -14.17 -10.90 Detect or Typ PK AV PK AV PK AV PK AV PK AV PK AV PK AV PK AV Polar (H/V) Frequency (MHz) Meter Reading (dBuV) V 11570.00 39.15 V 11570.00 30.95 V 17355.00 38.23 V 17355.00 30.87 V 23140.00 45.76 V 23140.00 37.70 V 28925.00 42.14 V 28925.00 34.78 H 11570.00 40.73 H 11570.00 32.02 H 17355.00 37.92 H 17355.00 30.39 H 23140.00 46.57 H 23140.00 38.87 H 28925.00 43.53 H 28925.00 35.51 Pre- Cable Antenna Emission amplifier Loss Factor Level (dB) (dB) (dB) (dBuV/m) Middle Channel:5785MHz 46.10 8.77 39.10 40.92 46.10 8.77 39.10 32.72 47.70 11.10 38.40 40.03 47.70 11.10 38.40 32.67 56.90 12.73 37.80 39.39 56.90 12.73 37.80 31.33 55.60 14.25 40.50 41.29 55.60 14.25 40.50 33.93 46.10 8.77 39.10 42.50 46.10 8.77 39.10 33.79 47.70 11.10 38.40 39.72 47.70 11.10 38.40 32.19 56.90 12.73 37.80 40.20 56.90 12.73 37.80 32.50 55.60 14.25 40.50 42.68 55.60 14.25 40.50 34.66 Limits (dBuV/m) 74.00 54.00 68.20 54.00 74.00 54.00 68.20 54.00 74.00 54.00 68.20 54.00 74.00 54.00 68.20 54.00 Margin (dB) -33.08 -21.28 -28.17 -21.33 -34.61 -22.67 -26.91 -20.07 -31.50 -20.21 -28.48 -21.81 -33.80 -21.50 -25.52 -19.34 Detect or Type PK AV PK AV PK AV PK AV PK AV PK AV PK AV PK AV Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 47 of 61 Report No.: ET-22092019E03 - Polar (H/V) V V V V V V V V H H H H H H H H Frequency (MHz) 11650.00 11650.00 17475.00 17475.00 23300.00 23300.00 29125.00 29125.00 11650.00 11650.00 17475.00 17475.00 23300.00 23300.00 29125.00 29125.00 Meter Reading (dBuV) 44.73 35.83 42.64 35.13 52.12 42.92 48.92 40.21 46.69 38.18 43.83 36.38 53.50 44.33 49.95 40.94 Pre- Cable Antenna Emission amplifier Loss Factor Level (dB) (dB) (dB) (dBuV/m) High Channel:5825MHz 46.10 8.77 39.10 46.10 8.77 39.10 47.90 11.23 38.90 47.90 11.23 38.90 57.10 12.73 37.80 57.10 12.73 37.80 55.80 14.25 40.50 55.80 14.25 40.50 46.10 8.77 39.10 46.10 8.77 39.10 47.90 11.23 38.90 47.90 11.23 38.90 57.10 12.73 37.80 57.10 12.73 37.80 55.80 14.25 40.50 55.80 14.25 40.50 46.50 37.60 44.87 37.36 45.55 36.35 47.87 39.16 48.46 39.95 46.06 38.61 46.93 37.76 48.90 39.89 Limits (dBuV/m) 74.00 54.00 68.20 54.00 68.20 54.00 68.20 54.00 74.00 54.00 68.20 54.00 68.20 54.00 68.20 54.00 Margin Detect or (dB) Type -27.50 PK -16.40 AV -23.33 PK -16.64 AV -22.65 PK -17.65 AV -20.33 PK -14.84 AV -25.54 PK -14.05 AV -22.14 PK -15.39 AV -21.27 PK -16.24 AV -19.30 PK -14.11 AV Remark: 1. Emission Level = Meter Reading + Antenna Factor + Cable Loss Pre-amplifier, Margin= Emission Level - Limit 2. If peak below the average limit, the average emission was no test. 3. The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible value has no need to be reported. 4. The worst mode is 802.11n20, only the worst data is recorded. Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 48 of 61 Report No.: ET-22092019E03 - 4.7.2 Conducted Emission Method Test Requirement: Test Method: Limit: Test setup: FCC Part15 C Section 15.209, Part 15E Section 15.407(b)(4) ANSI C63.10:2013 -27dBm/MHz Test Instruments: Test mode: Test results: Refer to section 3.0 for details Refer to section 2.2 for details Pass Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 49 of 61 - 5180-5240MHz 802.11a on channel 36 Test Plot Report No.: ET-22092019E03 802.11a on channel 40 802.11a on channel 48 802.11n20 on channel 36 802.11n20 on channel 40 802.11n20 on channel 48 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 50 of 61 Report No.: ET-22092019E03 - 802.11ac20 on channel 36 Test Plot 802.11ac20 on channel 40 802.11ac20 on channel 48 802.11n40 on channel 38 802.11n40 on channel 46 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 51 of 61 Report No.: ET-22092019E03 - 802.11ac40 on channel 38 Test Plot 802.11ac40 on channel 46 802.11ac80 on channel 42 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 52 of 61 - 5745-5825MHz 802.11a on channel 149 Test Plot Report No.: ET-22092019E03 802.11a on channel 157 802.11a on channel 165 802.11n20 on channel 149 802.11n20 on channel 157 802.11n20 on channel 165 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 53 of 61 Report No.: ET-22092019E03 - 802.11ac20 on channel 149 Test Plot 802.11ac20 on channel 157 802.11ac20 on channel 165 802.11n40 on channel 151 802.11n40 on channel 159 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 54 of 61 Report No.: ET-22092019E03 - 802.11ac40 on channel 151 Test Plot 802.11ac40 on channel 159 802.11ac80 on channel 155 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 55 of 61 Report No.: ET-22092019E03 - 4.8 Frequency stability Test Requirement: Test Method: Limit: Test Procedure: Test setup: FCC Part15 C Section 15.407(g) ANSI C63.10:2013, FCC Part 2.1055 Manufactures of U-NII devices are responsible for ensuring frequency stability such that an emission is maintained within the band of operation under all conditions of normal operation as specified a. The EUT was placed inside the environmental test chamber and powered by nominal DC voltage. b. Turn the EUT on and couple its output to a spectrum analyzer. c. Turn the EUT off and set the chamber to the highest temperature specified. d. Allow sufficient time (approximately 30 min) for the temperature of the chamber to stabilize, turn the EUT on and measure the operating frequency after 2, 5, and 10 Minutes. e. Repeat step 2 and 3 with the temperature chamber set to the lowest temperature. f. The test chamber was allowed to stabilize at +20 degree C for a minimum of 30 Minute s. The supply voltage was then adjusted on the EUT from 85% to 115% and the frequency record. Test Instruments: Test mode: Test results: Refer to section 3.0 for details Refer to section 2.2 for details Pass Remark: Set the EUT transmits at un-modulation mode to test frequency stability. Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 56 of 61 Report No.: ET-22092019E03 - Measurement data: Temp. (°C) -30 -20 -10 0 10 Operating Frequency (MHz) 5180 5190 5200 5210 5220 5230 5240 5180 5190 5200 5210 5220 5230 5240 5180 5190 5200 5210 5220 5230 5240 5180 5190 5200 5210 5220 5230 5240 5180 5190 5200 5210 5220 5230 5240 Frequency stability versus Temp. Power Supply: AC120V 0 minute 2 minute Measured Frequency (MHz) Measured Frequency (MHz) 5179.998 5180.076 5189.994 5199.950 5199.989 5199.975 5209.995 5209.953 5219.990 5219.968 5229.988 5229.961 5239.961 5239.969 5179.989 5179.952 5189.980 5189.942 5199.988 5199.950 5209.980 5209.942 5220.001 5219.963 5229.979 5229.941 5239.997 5239.959 5179.998 5179.961 5189.994 5189.956 5199.989 5199.951 5209.995 5209.957 5219.990 5219.952 5229.988 5229.950 5239.961 5239.923 5179.775 5179.940 5199.947 5189.950 5199.945 5199.941 5210.000 5209.942 5219.989 5219.949 5229.976 5229.967 5239.993 5239.939 5179.977 5179.952 5189.988 5189.942 5199.979 5199.950 5209.980 5209.942 5219.987 5219.963 5230.005 5229.941 5239.990 5239.959 5 minute Measured Frequency (MHz) 5179.798 5199.672 5199.697 5209.674 5219.689 5229.681 5239.689 5179.683 5189.682 5199.675 5209.664 5219.674 5299.667 5239.675 5179.662 5189.673 5199.663 5209.663 5219.670 5229.687 5239.659 5179.674 5189.665 5199.672 5209.663 5219.684 5229.661 5239.679 5179.683 5189.679 5199.673 5209.678 5219.673 5229.670 5239.643 10 minute Measured Frequency (MHz) 5179.927 5189.938 5199.929 5209.930 5219.936 5229.954 5239.939 5179.948 5189.944 5199.939 5209.945 5219.939 5229.937 5239.910 5179.927 5189.938 5199.929 5209.930 5219.936 5229.954 5239.926 5179.938 5189.939 5199.930 5299.937 5219.929 5229.950 5239.928 5179.939 5189.930 5199.938 5209.930 5219.950 5229.928 5239.946 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China 20 30 40 50 - Page 57 of 61 Report No.: ET-22092019E03 5180 5190 5200 5210 5220 5230 5240 5180 5190 5200 5210 5220 5230 5240 5180 5190 5200 5210 5220 5230 5240 5180 5190 5200 5210 5220 5230 5240 5180.002 5189.998 5199.993 5209.999 5219.994 5229.992 5239.965 5179.981 5189.992 5199.983 5209.984 5219.991 5230.009 5239.981 5179.993 5189.984 5199.992 5209.984 5220.005 5229.983 5240.001 5179.993 5189.984 5199.992 5209.984 5220.005 5229.983 5240.001 5179.992 5189.993 5199.984 5299.992 5219.984 5230.005 5239.983 5179.993 5189.984 5199.992 5209.984 5220.005 5229.983 5240.001 5179.992 5189.993 5199.984 5299.992 5219.984 5230.005 5239.983 5179.993 5189.984 5199.992 5209.984 5220.005 5229.983 5240.001 5179.985 5189.976 5199.984 5209.976 5219.997 5229.975 5239.993 5179.985 5189.976 5199.984 5209.976 5219.997 5229.975 5239.993 5179.771 5199.943 5199.941 5209.996 5219.985 5229.972 5239.989 5179.985 5189.976 5199.984 5209.976 5219.997 5229.975 5239.993 5179.936 5189.966 5199.991 5209.975 5219.966 5229.994 5239.982 5179.984 5179.984 5189.980 5199.975 5209.981 5219.976 5229.974 5179.963 5189.974 5199.965 5209.966 5219.973 5229.991 5239.963 5179.936 5189.966 5199.991 5209.975 5219.966 5229.994 5239.982 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 58 of 61 Report No.: ET-22092019E03 - Power Supply (VAC) 102 120 138 Operating Frequency (MHz) 5180 5190 5200 5210 5220 5230 5240 5180 5190 5200 5210 5220 5230 5240 5180 5190 5200 5210 5220 5230 5240 Frequency stability versus Voltage Temperature: 25°C 0 minute 2 minute Measured Frequency (MHz) Measured Frequency (MHz) 5180.002 5180.116 5189.998 5199.989 5199.993 5200.017 5209.999 5209.995 5219.994 5220.010 5229.992 5230.003 5239.965 5240.011 5179.988 5180.011 5189.984 5180.117 5199.992 5199.992 5209.985 5210.017 5220.005 5219.995 5229.983 5230.010 5240.001 5240.003 5180.002 5180.002 5189.998 5189.998 5199.993 5199.993 5209.999 5209.999 5219.994 5219.994 5229.992 5239.965 5229.992 5239.965 5 minute Measured Frequency (MHz) 5179.985 5189.976 5199.984 5209.976 5219.997 5229.975 5239.989 5179.984 5189.985 5199.976 5299.984 5219.976 5229.996 5239.975 5179.973 5189.984 5199.975 5209.976 5219.983 5230.001 5239.973 10 minute Measured Frequency (MHz) 5180.099 5199.974 5199.999 5209.977 5219.992 5229.985 5239.993 5179.984 5189.983 5199.977 5209.967 5219.977 5299.975 5239.979 5179.963 5189.974 5199.964 5209.966 5219.973 5229.996 5239.963 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 59 of 61 Report No.: ET-22092019E03 - Temp. (°C) -30 -20 -10 0 10 20 30 40 Operating Frequency (MHz) 5745 5755 5775 5785 5795 5825 5745 5755 5775 5785 5795 5825 5745 5755 5775 5785 5795 5825 5745 5755 5775 5785 5795 5825 5745 5755 5775 5785 5795 5825 5745 5755 5775 5785 5795 5825 5745 5755 5775 5785 5795 5825 5745 5755 5775 5785 Frequency stability versus Temp. Power Supply: AC 120V 0 minute 2 minute 5 minute Measured Measured Measured Frequency (MHz) Frequency (MHz) Frequency (MHz) 5744.979 5744.985 5744.977 5754.989 5754.992 5754.984 5775.010 5774.984 5775.001 5784.986 5784.976 5784.977 5794.982 5794.983 5794.973 5824.980 5824.912 5824.976 5744.976 5744.996 5744.971 5754.991 5754.998 5754.996 5774.990 5775.001 5774.977 5784.993 5784.993 5784.986 5795.003 5794.984 5794.984 5824.985 5824.993 5824.994 5744.986 5744.986 5744.987 5755.012 5754.993 5754.989 5775.008 5775.010 5774.992 5784.992 5784.986 5784.984 5794.981 5794.982 5794.975 5824.916 5824.984 5824.984 5744.980 5744.975 5744.987 5755.005 5754.991 5754.989 5774.986 5774.990 5774.992 5784.995 5784.993 5784.984 5794.993 5795.006 5794.975 5825.003 5824.985 5824.984 5744.980 5744.985 5744.976 5755.005 5755.002 5754.983 5774.986 5775.003 5774.975 5784.995 5784.985 5784.967 5794.993 5795.002 5794.974 5825.003 5825.000 5824.903 5744.996 5745.010 5744.985 5755.010 5754.982 5755.001 5774.995 5775.005 5774.986 5784.982 5785.005 5784.973 5794.976 5794.996 5794.967 5825.010 5825.011 5825.001 5744.986 5744.996 5744.970 5754.993 5754.998 5754.993 5775.010 5775.001 5774.994 5784.986 5784.993 5784.976 5794.982 5794.984 5794.993 5824.985 5824.993 5824.991 5744.996 5744.980 5744.987 5755.010 5755.005 5754.989 5774.995 5774.986 5774.992 5784.982 5784.995 5784.984 10 minute Measured Frequency (MHz) 5744.966 5754.955 5774.966 5784.973 5794.991 5824.983 5744.977 5754.991 5774.976 5784.963 5794.957 5824.991 5744.596 5754.980 5774.981 5784.984 5794.967 5824.963 5744.967 5754.993 5774.989 5784.973 5794.962 5824.897 5744.962 5754.974 5774.991 5784.967 5794.963 5824.966 5744.966 5754.985 5774.965 5784.992 5794.984 5824.993 5744.991 5754.963 5774.986 5784.986 5794.977 5824.992 5744.960 5754.993 5774.989 5784.973 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 60 of 61 Report No.: ET-22092019E03 - 5795 5825 5745 5755 50 5775 5785 5795 5825 5794.976 5825.010 5744.996 5754.990 5774.995 5784.982 5794.976 5825.010 5794.993 5825.003 5745.010 5754.982 5775.005 5785.005 5794.995 5825.015 5794.975 5824.984 5744.987 5755.000 5774.986 5784.973 5794.967 5825.001 5794.962 5824.897 5744.966 5754.985 5774.965 5784.993 5794.984 5824.993 Power Supply (VAC) 102 120 138 Operating Frequency (MHz) 5745 5755 5775 5785 5795 5825 5745 5755 5775 5785 5795 5825 5745 5755 5775 5785 5795 5825 Frequency stability versus Voltage Temperature: 25°C 0 minute 2 minute 5 minute Measured Measured Measured Frequency (MHz) Frequency (MHz) Frequency (MHz) 5744.975 5744.985 5744.976 5754.991 5754.992 5754.993 5774.990 5774.984 5774.994 5784.993 5784.976 5784.976 5795.004 5794.983 5794.994 5824.985 5824.912 5824.991 5744.975 5744.996 5744.971 5754.991 5754.998 5754.996 5774.990 5775.001 5774.977 5784.993 5784.993 5784.986 5795.000 5794.984 5794.984 5824.985 5824.993 5824.994 5744.996 5745.009 5744.987 5755.010 5754.982 5755.001 5774.995 5775.005 5774.986 5784.982 5785.005 5784.973 5794.976 5794.996 5794.967 5825.010 5825.011 5825.001 10 minute Measured Frequency (MHz) 5744.961 5754.986 5774.967 5784.976 5794.974 5824.984 5744.977 5754.991 5774.976 5784.963 5794.957 5824.991 5744.966 5754.985 5774.965 5784.992 5794.984 5824.993 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China - Page 61 of 61 - 5 Test Setup Photo Reference to the appendix I for details. 6 EUT Constructional Details Reference to the appendix II for details. ------END------ Report No.: ET-22092019E03 Tel:(86-755) 85259392 Email:[email protected] Web: www.etrlab.cn No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China
Related FCC IDs:
- 2A8WI-XSERIES - EP-TEC Solutions Pte Ltd InfinityPro Interactive Flat Panel [-XSERIES] Acrobat Distiller 10.1.16 (Windows)