ET-22092019E03-FCC 15.407E 5G WIFI

Admin

Test Report

EP-TEC Solutions Pte Ltd XSERIES InfinityPro Interactive Flat Panel 2A8WI-XSERIES 2A8WIXSERIES xseries

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 61 Pages, 3.76MB

Document DEVICE REPORTGetApplicationAttachment.html?id=6180882
Report No.: ET-22092019E03

TEST REPORT

Applicant:
Address of Applicant:
Manufacturer/Factory:
Address of Manufacturer
Product Name:
Model No.: Trade Mark: FCC ID: Applicable standards: Date of Test: Date of report issued: Test Result :

EP-TEC Solutions Pte Ltd
2 Sims Close #05-07 Gemini @ Sims Singapore 387298
EP-TEC Solutions Pte Ltd
2 Sims Close #05-07 Gemini @ Sims Singapore 387298
InfinityPro Interactive Flat Panel
X Series, V Series, E Series InfinityPro 2A8WI-XSERIES FCC CFR Title 47 Part 15 Subpart E Section 15.407 Sep.23, 2022- Oct.14, 2022 Oct.18, 2022 PASS *

Remark: * In the configuration tested, the EUT complied with the standards specified above.
The results shown in this test report refer only to the sample(s) tested , this test report cannot be reproduced, except in full without prior written permission of the company.
The report would be invalid without specific stamp of test institute and the signatures of compiler and approver

Prepared By
Shenzhen ETR Standard Technology Co., Ltd.
Address: No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

Compiled by:

Reviewed by:

Approved by:

Project Engineer

Project Manager

Authorized Signature

This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen ETR Standard Technology Co., Ltd.

- Page 2 of 61 -

Report No.: ET-22092019E03

Report No. ET-22092019E03

Report Revision History
Description Original

Issue Date Oct.18, 2022

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 3 of 61 -
Contents

Report No.: ET-22092019E03 Page

1 TEST SUMMARY ..................................................................................................................................... 4
1.1 MEASUREMENT UNCERTAINTY ............................................................................................................ 4
2 GENERAL INFORMATION ...................................................................................................................... 5
2.1 GENERAL DESCRIPTION OF EUT ......................................................................................................... 5 2.2 TEST MODE ........................................................................................................................................ 7 2.3 DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 8 2.4 DEVIATION FROM STANDARDS ............................................................................................................. 8 2.5 ABNORMALITIES FROM STANDARD CONDITIONS ................................................................................... 8 2.6 TEST FACILITY.................................................................................................................................... 8 2.7 TEST LOCATION ................................................................................................................................. 8 2.8 ADDITIONAL INSTRUCTIONS................................................................................................................. 8
3 TEST INSTRUMENTS LIST ..................................................................................................................... 9
4 TEST RESULTS AND MEASUREMENT DATA.................................................................................... 10
4.1 ANTENNA REQUIREMENT ................................................................................................................... 10 4.2 CONDUCTED EMISSIONS ................................................................................................................... 11 4.3 CONDUCTED PEAK OUTPUT POWER .................................................................................................. 14 4.4 CHANNEL BANDWIDTH ...................................................................................................................... 16 4.5 POWER SPECTRAL DENSITY ............................................................................................................. 24 4.6 BAND EDGE ...................................................................................................................................... 32
4.6.1 Conducted test Method.............................................................................................................. 32 4.7 SPURIOUS EMISSION......................................................................................................................... 39
4.7.1 Radiated Emission Method ........................................................................................................ 39 4.7.2 Conducted Emission Method ..................................................................................................... 48 4.8 FREQUENCY STABILITY ..................................................................................................................... 55
5 TEST SETUP PHOTO ............................................................................................................................ 61
6 EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 61

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 4 of 61 -

Report No.: ET-22092019E03

1 Test Summary

Test Item

Section in CFR 47

Antenna requirement

15.203

AC Power Line Conducted Emission

15.207

Conducted Output Power

15.407 (a)(1)/(a)(3)

26dB Bandwidth and 99% Occupied Bandwidth

15.407 (a)(12)

6dB Bandwidth

15.407 (e)

Power Spectral Density

15.407(a)(1)/(a)(3)

Band Edge

15.407(b)(1)/(b)(4)

Spurious Emission

15.205/15.209 15.407(b)(1)/(b)(4)/(b)(8)

Frequency Stability

15.407(g)

Remarks

1. Pass: The EUT complies with the essential requirements in the standard.

2. Test according to ANSI C63.10:2013.

Result Pass Pass Pass
Pass
Pass Pass Pass
Pass
Pass

Test by /
Carr Kang Yvan Fan
Yvan Fan
Yvan Fan Yvan Fan Yvan Fan
Qiao Li
Yvan Fan

1.1 Measurement Uncertainty

Test Item

Measurement Uncertainty

Notes

Occupied Channel Bandwidth

±0.55%

(1)

RF output power, conducted

±0.99dB

(1)

Power Spectral Density, conducted

±0.61dB

(1)

Unwanted Emissions, conducted

±0.64dB

(1)

AC Power Line Conducted Emission

± 3.02dB

(1)

Radiated emissions 9K-30MHz

±3.98dB

(1)

Radiated emissions 30M- 1GHz

±4.30dB

(1)

Radiated emissions 1GHz-18GHz

±4.35dB

(1)

Radiated emissions 18GHz-40GHz

±4.59 dB

(1)

Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%.

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 5 of 61 -

Report No.: ET-22092019E03

2 General Information

2.1 General Description of EUT

Product Name: Model No.:

InfinityPro Interactive Flat Panel X Series, V Series, E Series

Difference of model(s) All the models are the same circuit and RF module, except the appearance color.

Test Model: Hardware Version: Software Version: Sample(s) Status: Operation Frequency:
Channel numbers:
Channel bandwidth:
Data Rate Modulation technology: Antenna Type:

X Series
N/A N/A
Engineer sample
5180-5240MHz for 802.11a/n(HT20)/ac20; 5190-5230MHz for 802.11n(HT40)/ac40; 5210MHz for 802.11 ac80; 5745-5825 MHz for 802.11a/n(HT20)/ac20; 5755-5795 MHz for 802.11n(HT40)/ac40; 5775MHz for 802.11 ac80; 4 channels for 802.11a/n20/ac20 in the 5180-5240MHz band; 2 channels for 802.11 n40/ac40 in the 5190-5230MHz band ; 1 channels for 802.11 ac80 in the 5210MHz band ; 5 channels for 802.11a/n20/ac20 in the 5745-5825MHz band ; 2 channels for 802.11 n40/ac40 in the 5755-5795MHz band ; 1 channels for 802.11 ac80 in the 5775MHz band 802.11a/802.11n(HT20)/ 802.11ac(HT20): 20MHz 802.11n(HT40)/ 802.11ac(HT40) : 40MHz 802.11ac(HT80) : 80MHz 802.11a: 6,9,12,18,24,36,48,54Mbps; 802.11n(HT20/HT40):MCS0-MCS15; 802.11ac(VHT/20/40/80):NSS1, MCS0-MCS9 Orthogonal Frequency Division Multiplexing (OFDM)
with BPSK/QPSK/16QAM/64QAM/256QAM
External antenna

Antenna gain:

2.76dBi(Declare by applicant)

Power supply:

AC 100-240V 50/60Hz

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 6 of 61 -

Report No.: ET-22092019E03

Channel 36 44
Channel 149 157 165

Frequency 5180MHz 5220MHz Frequency 5745MHz 5785MHz 5825MHz

Operation Frequency each of channel

Channel Frequency Channel Frequency

38

5190MHz

40

5200MHz

46

5230MHz

48

5240MHz

Channel Frequency Channel Frequency

151

5755MHz

153

5765MHz

159

5795MHz

161

5805MHz

/

Channel 42 /
Channel 155 /

Frequency 5210MHz
/ Frequency 5775MHz
/

Note:

In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the middle frequency, and the highest frequency of channel were selected to perform the test, and the selected channel see below:

Test channel Lowest channel

802.11 a /n(HT20)/ac(HT20) 5180

Frequency (MHz) 802.11 n(HT40)/ac(HT40)
5190

802.11ac(HT80) 5210

Middle channel

5200

Highest channel

5240

5230

Test channel
Lowest channel Middle channel Highest channel

802.11 a /n(HT20)/ac(HT20) 5745 5785 5825

Frequency (MHz) 802.11 n(HT40)/ac(HT40)
5755
5795

802.11ac(HT80) 5775

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 7 of 61 -

Report No.: ET-22092019E03

2.2 Test mode

Transmitting mode

Keep the EUT in continuously transmitting mode(or with a duty cycle  98%)

Remark: During the test, the test voltage was tuned from 85% to 115% of the nominal rated supply voltage, and found that the worst case was under the nominal rated supply condition. So the report just shows that condition's data.

We have verified the construction and function in typical operation. All the test modes were carried out with the EUT in transmitting operation, which was shown in this test report and defined as follows:

Pretest Mode Mode 1
Mode 2 Mode 3 Mode 4 Mode 5

Description 802.11a / n 20 CH36/ CH40/ CH 48 802.11a /n 20 CH149/ CH157/ CH 165
802.11n 40 CH38/ CH 46 802.11n 40 CH 151 / CH 159 802.11 ac80 CH 42/CH 155 802.11a / n 20 CH36/ CH40/ CH 48 802.11a /n 20 CH149/ CH157/ CH 165
Link Mode

Final Test Mode Mode 5

Conducted Emission Description Link Mode

Final Test Mode Mode 1
Mode 2 Mode 3 Mode 4 Note:

For Radiated Emission Description
802.11a / n 20 CH36/ CH40/ CH 48 802.11a /n 20 CH149/ CH157/ CH 165
802.11n 40 CH38/ CH 46 802.11n 40 CH 151 / CH 159 802.11 ac80 CH 42/CH 155 802.11a / n 20 CH36/ CH40/ CH 48 802.11a /n 20 CH149/ CH157/ CH 165

(1) The measurements are performed at all Bit Rate of Transmitter, the worst data was reported.

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 8 of 61 -

Report No.: ET-22092019E03

2.3 Description of Support Units

No.

Description

Manufacturer

Model

/

/

/

/

2.4 Deviation from Standards None.

2.5 Abnormalities from Standard Conditions

None.
2.6 Test Facility

Test laboratory:

Shenzhen ETR Standard Technology Co., Ltd.

CNAS Registration Number: L11864

A2LA Certificate Number:

6640.01

FCC Designation Number: FCC Test Firm Registration:

CN1326 183064

Serial Number /

2.7 Test Location

All tests were performed at:

Laboratory location:

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

Telephone:

+86 755 85259392

2.8 Additional Instructions

Test Software

RFTestTool.apk

Power level setup

Default

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 9 of 61 -

Report No.: ET-22092019E03

3 Test Instruments list

Conducted Emission

Item

Equipment name

1

EMI Test Receiver

2

amplifier

3

Artificial power network

4

Artificial power network

5

10dB attenuator

6

Cable 4

7

Absorbing Clamp

Manufacturer Rohde&schwarz
EMtrace schwarabeck
ETS HUBER+SUHNER HUBER SUNNER
schwarabeck

Model ESCI3 RP01A NSLK8127
3186/2NM 10dB 3M
MDS21

Serial No. 100605 50117 8127483
1132 / /
D69250

Calibration date
2022.3.09 2022.3.09
2022.3.09
2022.3.09
2022.3.09 2022.3.09 2022.3.11

Due date 2023.3.08 2023.3.08 2023.3.08
2023.3.08 2023.3.08 2022.3.08 2023.3.10

Radiated Emission &RF Conducted test:

Item Equipment name

Manufacturer

1 EMI Test Receiver 2 Broadband antenna

3

Horn antenna

4

amplifier

5

amplifier

6

Spectrum analyzer

7

Power detector box

8

Signal generator

9

Spectrum analyzer

10

amplifier

11

Horn antenna

12

Loop antenna

13

Cable 6

14

Cable7

15

Cable8

Rohde&schwarz schwarabeck schwarabeck EMtrace Space-Dtronics KEYSIGHT MWRFtest Agilent
Rohde&schwarz Aeroflex
Com-Power schwarabeck HUBER SUNNER HUBER SUNNER HUBER SUNNER

Model
ESPI7 VULB9168 BBHA9120D
RP01A EWLAN0118G-P40
N9020A MW100-PSB
N5182A FSV40 DLE-161 SAS-574 FMZB 1519 B 0.5M 2.0M 6.0M

Serial No.
100605 1064
9120D-1145 50117
19113001 MY55370280 MW201020JYT MY49060455
100363 097 588 1519 / / /

Calibration date
2022.3.09 2022.3.11 2022.3.11
2022.3.09
2022.3.09
2022.3.09 2021.11.19
2021.11.19 2022.3.09 2022.3.09 2022.3.11 2022.3.11
2022.3.09 2022.3.09 2022.3.09

Due date
2023.3.08 2024.3.10 2024.3.10 2023.3.08 2023.3.08 2023.3.08 2022.11.18 2022.11.18 2023.3.08 2023.3.08 2024.3.10 2024.3.10 2023.3.08 2023.3.08 2023.3.08

Note: the calibration interval of the above test instruments is 12 or 24 months and the calibrations are traceable to international system unit (SI).

Software Name RF test software Conducted test software Radiated test software

Manufacturer MWRFtest EZ-EMC EZ-EMC

Model MTS 8310
Farad Farad

Version V2.0.0.0 Ver.EMC-CON 3A1.1 Ver.FA-03A2 RE

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 10 of 61

Report No.: ET-22092019E03

-

4 Test results and Measurement Data

4.1 Antenna requirement

Standard requirement:

FCC Part15 C Section 15.203

15.203 requirement:

An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. The use of a permanently attached antenna or of an

antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited.
E.U.T Antenna:

The antennas are External antenna, the best case gain of the antennas are 2.76dBi, reference to the appendix II for details

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 11 of 61

Report No.: ET-22092019E03

-

4.2 Conducted Emissions

Test Requirement: Test Method: Test Frequency Range: Class / Severity: Receiver setup: Limit:
Test setup:

FCC Part15 C Section 15.207

ANSI C63.10:2013

150KHz to 30MHz

Class B RBW=9KHz, VBW=30KHz, Sweep time=auto

Frequency range (MHz)

Limit (dBuV)

Quasi-peak

Average

0.15-0.5

66 to 56*

56 to 46*

0.5-5

56

46

5-30

60

50

* Decreases with the logarithm of the frequency.

Test procedure:
Test Instruments: Test mode: Test environment: Test voltage: Test results:

1. The E.U.T and simulators are connected to the main power through a line impedance stabilization network (L.I.S.N.). This provides a 50ohm/50uH coupling impedance for the measuring equipment.

2. The peripheral devices are also connected to the main power through a LISN that provides a 50ohm/50uH coupling impedance with 50ohm termination. (Please refer to the block diagram of the test setup and photographs).

3. Both sides of A.C. line are checked for maximum conducted interference. In order to find the maximum emission, the relative positions of equipment and all of the interface cables must be changed according to ANSI C63.10:2013 on conducted measurement.

Refer to section 3.0 for details

Refer to section 2.2 for details

Temp.:

24.7C

Humid.: 50%

Press.:

1012mbar

AC 120V, 60Hz

Pass

Remark: Both high voltage and low voltage have been tested, and the report only shows the worst case data with AC 120V/60Hz.

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

-
Measurement data Line:

- Page 12 of 61

Report No.: ET-22092019E03

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

Neutral:

- Page 13 of 61

Report No.: ET-22092019E03

Notes: 1. An initial pre-scan was performed on the line and neutral lines with peak detector. 2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak
emission. 3. Final Level =Receiver Read level + LISN Factor + Cable Loss 4. If the average limit is met when using a quasi-peak detector receiver, the EUT shall be deemed to meet both limits and measurement with the average detector receiver is unnecessary.

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 14 of 61

Report No.: ET-22092019E03

-

4.3 Conducted Peak Output Power

Test Requirement: Test Method: Limit:
Test setup:

FCC Part15 E Section 15.407 (a)(1)/(a)(3)
ANSI C63.10:2013 and KDB 789033 D02 General U-NII Test Procedures New Rules v02r01
5150-5250MHz : 250mW 5725~5850MHz : 1W

Test Instruments: Test mode: Test results:

Measurement Data Test Channel Frequency (MHz)

CH36 CH40 CH48
CH36 CH40 CH48
CH36 CH40 CH48
CH38 CH46
CH38 CH46
CH42

5180 5200 5240
5180 5200 5240
5180 5200 5240
5190 5230
5190 5230
5210

Refer to section 3.0 for details
Refer to section 2.2 for details Pass
Maximum output power
(dBm)
TX 802.11a Mode 13.93 13.56 13.73
TX 802.11 n20 Mode 13.77 13.57 13.68
TX 802.11 ac20 Mode 13.12 12.76 13.03
TX 802.11 n40 Mode 12.58 12.47
TX 802.11 ac40 Mode 12.66 12.47
TX 802.11 ac80 Mode 11.77

LIMIT dBm
23.98 23.98 23.98
23.98 23.98 23.98
23.98 23.98 23.98
23.98 23.98
23.98 23.98
23.98

Result
Pass Pass Pass
Pass Pass Pass
Pass Pass Pass
Pass Pass
Pass Pass
Pass

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 15 of 61

Report No.: ET-22092019E03

-

Test Channel Frequency (MHz)

CH149 CH157 CH165
CH149 CH157 CH165
CH149 CH157 CH165
CH151 CH159
CH151 CH159
CH155

5745 5785 5825
5745 5785 5825
5745 5785 5825
5755 5795
5755 5795
5775

Maximum output power.
(dBm)
TX 802.11a Mode 12.30 12.58 12.84
TX 802.11 n20 Mode 11.73 11.96 12.10
TX 802.11 ac20 Mode 11.58 11.89 12.16
TX 802.11 n40 Mode 11.59 11.80
TX 802.11 ac40 Mode 11.63 11.78
TX 802.11 ac80 Mode 12.34

LIMIT dBm
30 30 30
30 30 30
30 30 30
30 30
30 30
30

Result
Pass Pass Pass
Pass Pass Pass
Pass Pass Pass
Pass Pass
Pass Pass
Pass

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 16 of 61

Report No.: ET-22092019E03

-

4.4 Channel Bandwidth
Test Requirement: Test Method: Limit:
Test setup:

FCC Part15 E Section 15.407(a)(12)&15.407(e)
ANSI C63.10:2013 and KDB 789033 D02 General U-NII Test Procedures New Rules v02r01
Measurements in the 5.725-5.85 GHz band, the minimum bandwidth 6 dB bandwidth of U-NII devices shall be at least 500KHz. Measurements in the 5.15-5.25 GHz, 5.25-5.35 GHz, and the 5.47-5.725 GHz bands are made over a bandwidth of 1 MHz or the 26 dB emission bandwidth of the device, whichever is less. A narrower resolution bandwidth can be used, provided that the measured power is integrated over the full reference bandwidth.

Test Instruments: Test mode: Test results: Measurement Data 5180-5240MHz

Test CH
Lowest Middle Highest

802.11a
23.51 24.26 22.98

Refer to section 3.0 for details Refer to section 2.2 for details Pass

-26dB Channel Bandwidth (MHz)

802.11n (HT20)

802.11ac (HT20)

802.11n (HT40)

802.11ac (HT40)

24.58

23.81

44.20

43.38

24.12

24.64

--

--

24.33

24.82

44.13

44.56

802.11ac (HT80) -82.41 --

Result Pass

Test CH
Lowest Middle Highest

802.11a
16.843 16.886 16.850

99% Occupy Bandwidth (MHz)

802.11n (HT20)

802.11ac (HT20)

802.11n (HT40)

802.11ac (HT40)

17.978

17.951

36.245

36.279

17.979

17.968

--

--

17.934

17.928

36.264

36.266

802.11ac (HT80) -75.193 --

Result Pass

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 17 of 61

Report No.: ET-22092019E03

-

(802.11a) plot on channel 36

Test plot

(802.11 n20) plot on channel 36

(802.11a) plot on channel 40

(802.11 n20) plot on channel 40

(802.11a) plot on channel 48

(802.11 n20) plot on channel 48

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 18 of 61

Report No.: ET-22092019E03

-

(802.11ac20) plot on channel 36

Test plot

(802.11 n40) plot on channel 38

(802.11ac20) plot on channel 40

(802.11 n40) plot on channel 46

(802.11ac20) plot on channel 48

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 19 of 61

Report No.: ET-22092019E03

-

(802.11ac40) plot on channel 38

Test plot

(802.11ac80) plot on channel 42

(802.11ac40) plot on channel 46

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 20 of 61

Report No.: ET-22092019E03

-

5745-5825MHz

-6dB Channel Bandwidth (MHz)

Test CH

802.11a

802.11n (HT20)

802.11ac (HT20)

802.11n (HT40)

802.11ac (HT40)

Lowest

16.32

17.56

17.57

36.02

36.29

Middle

16.32

17.58

17.58

--

--

Highest

16.31

17.57

17.56

36.33

36.30

Remark: "---"is not applicable

802.11ac (HT80) -75.11 --

Limit (KHz)
>500

Result Pass

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 21 of 61

Report No.: ET-22092019E03

-

(802.11a) plot on channel 149

Test plot

(802.11 n20) plot on channel 149

(802.11a) plot on channel 157

(802.11 n20) plot on channel 157

(802.11a) plot on channel 165

(802.11 n20) plot on channel 165

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 22 of 61

Report No.: ET-22092019E03

-

(802.11ac20) plot on channel 149

Test plot

(802.11 n40) plot on channel 151

(802.11ac20) plot on channel 157

(802.11 n40) plot on channel 159

(802.11ac20) plot on channel 165

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 23 of 61

Report No.: ET-22092019E03

-

(802.11 ac40) plot on channel 151

Test plot

(802.11 ac80) plot on channel 155

(802.11 ac40) plot on channel 159

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 24 of 61

Report No.: ET-22092019E03

-

4.5 Power Spectral Density

Test Requirement: Test Method: Limit:
Test setup:

FCC Part15 E Section 15.407(a)(1)/ (a)(3)

ANSI C63.10:2013 and KDB 789033 D02 General U-NII Test Procedures New Rules v02r01

Frequency band (MHz)
5150-5250
5250-5350 5470-5725
725-5850

Limit
17dBm/1MHz for master device 11dBm/1MHz for client device 11dBm/1MHz for client device 11dBm/1MHz for client device 30dBm/500kHz

Test Instruments: Test mode: Test results: Measurement Data 5180-5240MHz
Mode
802.11 a
802.11 n20
802.11 ac20
802.11 n40
802.11 ac40 802.11 ac80

Refer to section 3.0 for details Refer to section 2.2 for details Pass

Frequency
5180 MHz 5200 MHz 5240 MHz 5180 MHz 5200 MHz 5240 MHz 5180 MHz 5200 MHz 5240 MHz 5190 MHz 5230 MHz 5190 MHz 5230 MHz 5210 MHz

Measured Power Density (dBm/MHz)
5.938 5.404 5.686 5.195 5.098 5.106 4.56 4.413 4.526 1.877 1.112 1.537 1.288 -1.624

Limit (dBm/MHz)
11 11 11 11 11 11 11 11 11 11 11 11 11 11

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 25 of 61

Report No.: ET-22092019E03

-

(802.11a) PSD plot on channel 36

(802.11n20) PSD plot on channel 36

(802.11a) PSD plot on channel 40

(802.11n20) PSD plot on channel 40

(802.11a) PSD plot on channel 48

(802.11n20) PSD plot on channel 48

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 26 of 61

Report No.: ET-22092019E03

-

(802.11ac20) PSD plot on channel 36

(802.11n40) PSD plot on channel 38

(802.11ac20) PSD plot on channel 40

(802.11n40) PSD plot on channel 46

(802.11ac20) PSD plot on channel 48

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 27 of 61

Report No.: ET-22092019E03

-

(802.11ac40) PSD plot on channel 38

(802.11ac80) PSD plot on channel 42

(802.11ac40) PSD plot on channel 46

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 28 of 61

Report No.: ET-22092019E03

-

Mode
802.11 a
802.11 n20
802.11 ac20 802.11 n40 802.11 ac40 802.11 ac80

Frequency
5745 MHz 5785 MHz 5825 MHz 5745 MHz 5785 MHz 5825 MHz 5745 MHz 5785 MHz 5825 MHz 5755 MHz 5795 MHz 5755 MHz 5795 MHz 5775 MHz

Measured Power
Density
(dBm/510KHz) 1.271 0.829 0.473 -0.266 -0.084 -0.027 -0.499 -0.282 0.0250 -2.509 -2.910 -2.812 -3.244 -5.405

Measured Power
Density
(dBm/500KHz) 1.185 0.743 0.387 -0.352 -0.170 -0.113 -0.585 -0.368 -0.061 -2.595 -2.996 -2.898 -3.330 -5.491

Limit
(dBm/MHz)
30 30 30 30 30 30 30 30 30 30 30 30 30 30

Note: If the measurement is X dBm/510kHz, thus X dBm/510kHz = (10X/10)*(500 / 510) dBm/500kHz

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 29 of 61

Report No.: ET-22092019E03

-

(802.11a) PSD plot on channel 149

(802.11n20) PSD plot on channel 149

(802.11a) PSD plot on channel 157

(802.11n20) PSD plot on channel 157

(802.11a) PSD plot on channel 165

(802.11n20) PSD plot on channel 165

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 30 of 61

Report No.: ET-22092019E03

-

(802.11ac20) PSD plot on channel 149

(802.11n40) PSD plot on channel 151

(802.11ac20) PSD plot on channel 157

(802.11n40) PSD plot on channel 159

(802.11ac20) PSD plot on channel 165

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 31 of 61

Report No.: ET-22092019E03

-

(802.11ac40) PSD plot on channel 151

(802.11ac80) PSD plot on channel 155

(802.11ac40) PSD plot on channel 159

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 32 of 61

Report No.: ET-22092019E03

-

4.6 Band edge

4.6.1 Conducted test Method

Test Requirement: Test Method: Limit:
Test setup:

FCC Part15 C Section 15.209 and 15.205
ANSI C63.10: 2013
All emissions shall be limited to a level of -27 dBm/MHz at 75 MHz or more above or below the band edge increasing linearly to 10 dBm/MHz at 25 MHz above or below the band edge, and from 25 MHz above or below the band edge increasing linearly to a level of 15.6 dBm/MHz at 5 MHz above or below the band edge, and from 5 MHz above or below the band edge increasing linearly to a level of 27 dBm/MHz at the band edge.

Test Procedure:
Test Instruments: Test mode: Test results: Remarks:/

1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal from an external generator.
2. Position the EUT without connection to measurement instrument. Turn on the EUT and connect its antenna terminal to measurement instrument via a low loss cable. Then set it to any one measured frequency within its operating range, and make sure the instrument is operated in its linear range.
3. Set RBW of spectrum analyzer to 1 MHz with a convenient frequency span.
4. Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the graph with marking the highest point and edge frequency.
5. Repeat above procedures until all measured frequencies were complete..
Refer to section 3.0 for details
Refer to section 2.2 for details
Pass

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 33 of 61

Report No.: ET-22092019E03

-

5.180~5.240 GHz

(802.11a) Band Edge, Left Side

(802.11n20) Band Edge, Left Side

(802.11a) Band Edge, Right Side

(802.11n20) Band Edge, Right Side

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 34 of 61

Report No.: ET-22092019E03

-

5.180~5.240 GHz

(802.11ac20) Band Edge, Left Side

(802.11n40) Band Edge, Left Side

(802.11ac20) Band Edge, Right Side

(802.11n40) Band Edge, Right Side

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 35 of 61

Report No.: ET-22092019E03

-

5.180~5.240 GHz (802.11ac40) Band Edge, Left Side

(802.11ac80) Band Edge

(802.11ac40) Band Edge, Right Side

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 36 of 61

Report No.: ET-22092019E03

-

5.745~5.825 GHz

(802.11a) Band Edge, Left Side

(802.11n20) Band Edge, Left Side

(802.11a) Band Edge, Right Side

(802.11n20) Band Edge, Right Side

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 37 of 61

Report No.: ET-22092019E03

-

5.745~5.825 GHz

(802.11ac20) Band Edge, Left Side

(802.11n40) Band Edge, Left Side

(802.11ac20) Band Edge, Right Side

(802.11n40) Band Edge, Right Side

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 38 of 61

Report No.: ET-22092019E03

-

5.745~5.825 GHz (802.11ac40) Band Edge, Left Side

(802.11ac80) Band Edge

(802.11ac40) Band Edge, Right Side

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 39 of 61

Report No.: ET-22092019E03

-

4.7 Spurious Emission

4.7.1 Radiated Emission Method

Test Requirement:

FCC Part15 C Section 15.209, Part 15E Section 15.407(b)(4)

Test Method:

ANSI C63.10:2013

Test Frequency Range: 9kHz to 40GHz

Test site:

Measurement Distance: 3m

Receiver setup: Limit:

Frequency 9kHz-150KHz 150kHz-30MHz 30MHz-1GHz
Above 1GHz

Detector Quasi-peak Quasi-peak Quasi-peak
Peak AV

RBW 200Hz 9kHz 120KHz 1MHz 1MHz

Frequency

Limit (uV/m)

VBW 1kHz 30kHz 300KHz 3MHz 3MHz
Value

Value Quasi-peak Value Quasi-peak Value Quasi-peak Value
Peak Value Average Value
Measurement Distance

0.009MHz-0.490MHz 2400/F(KHz)

QP

0.490MHz-1.705MHz 24000/F(KHz)

QP

1.705MHz-30MHz

30

QP

30MHz-88MHz

100

QP

88MHz-216MHz

150

QP

216MHz-960MHz

200

QP

960MHz-1GHz

500

QP

300m 300m 30m
3m

Test setup:

Frequency Above 1GHz

Limit (dBm/MHz) -27.0

For radiated emissions from 9kHz to 30MHz

Remark Peak Value

For radiated emissions from 30MHz to1GHz

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 40 of 61

Report No.: ET-22092019E03

-

For radiated emissions above 1GHz

Test Procedure:

1. The EUT was placed on the top of a rotating table (0.8m for below 1GHz and 1.5 meters for above 1GHz) above the ground at a 3 meter camber. The table was rotated 360 degrees to determine the position of the highest radiation.
2. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top of a variable-height antenna tower.
3. The antenna height is varied from one meter to four meters above the ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to make the measurement.
4. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to heights from 1 meter to 4 meters and the rota table was turned from 0 degrees to 360 degrees to find the maximum reading.
5. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum Hold Mode.
6. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that did not have 10dB margin would be re-tested one by one using peak, quasi-peak or average

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 41 of 61

Report No.: ET-22092019E03

-

method as specified and then reported in a data sheet.

7. The radiation measurements are performed in X, Y, Z axis positioning. And found the X axis positioning which it is worse case, only the test worst case mode is recorded in the report.

Test Instruments:

Refer to section 3.0 for details

Test mode:

Refer to section 2.2 for details

Test environment: Test voltage:

Temp.:

24.9 C

DC 5V from adapter

Humid.:

51%

Press.: 1012mbar

Test results:

Pass

Remarks:

1. All antennas was tested, only show the worst case 802.11n20 mode test data. 2. Pre-scan all kind of the place mode (X-axis, Y-axis, Z-axis), and found the Y-axis which it is worse case.

3. According to KDB 789033 D02v02r01 section G) 1) d),for measurements above 1000 MHz @3m distance, the limit of field strength is computed as follows: E[dBuV/m] = EIRP[dBm] + 95.2; For example, if EIRP = -27dBm E[dBuV/m] = -27 + 95.2 = 68.2dBuV/m.

Measurement Data:

9 kHz ~ 30 MHz The emission from 9 kHz to 30MHz was pre-tested and found the result was 20dB lower than the limit, and according to 15.31(o) & RSS-Gen 6.13, the test result no need to reported.

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 42 of 61

Report No.: ET-22092019E03

-

Below 1GHz Temperature Pressure Test Mode 

25.4 1010 hPa 5.2G TX- 802.11n20

Horizontal:

Relative Humidity 47%

Test Voltage 

AC 120V

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

Vertical:

- Page 43 of 61

Report No.: ET-22092019E03

Remarks: 1. Final Level =Receiver Read level + Antenna Factor + Cable Loss ­ Preamplifier Factor 2. The emission levels of other frequencies are very lower than the limit and not show in test report. 3. The test data shows only the worst case 802.11n20 mode

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 44 of 61

Report No.: ET-22092019E03

-

Above 1GHz:

Temperature Pressure Test Mode 

25.4 1010 hPa 5.2G TX- 802.11n20

Relative Humidity 47%

Test Voltage 

AC 120V

Polar (H/V)

Frequency (MHz)

Meter Read n
g
(dBuV)

V 10360.00 46.11 V 10360.00 36.79 V 15540.00 43.41 V 15540.00 34.04 V 20720.00 51.92 V 20720.00 42.54 V 25900.00 49.72 V 25900.00 39.96 H 10360.00 46.04 H 10360.00 35.51 H 15540.00 42.49 H 15540.00 31.75 H 20720.00 54.00 H 20720.00 43.38 H 25900.00 50.67 H 25900.00 40.00

Preamplifie
r

802.11n20
Cable Antenna Loss Factor

Emission Level

(dB)

(dB)

(dB) (dBuV/m)

46.20 46.20 46.30 46.30 57.40 57.40 56.50 56.50 46.20 46.20 46.30 46.30 57.40 57.40 56.50 56.50

Low Channel:5180MHz

8.27 38.50

46.68

8.27 38.50

37.36

10.35 38.70

46.16

10.35 38.70

36.79

11.93 37.80

44.25

11.93 37.80

34.87

13.45 39.70

46.37

13.45 39.70

36.61

8.27 38.50

46.61

8.27 38.50

36.08

10.35 38.70

45.24

10.35 38.70

34.50

11.93 37.80

46.33

11.93 37.80

35.71

13.45 39.70

47.32

13.45 39.70

36.65

Limits
(dBuV/m)
68.20 54.00 74.00 54.00 68.20 54.00 68.20 54.00 68.20 54.00 74.00 54.00 68.20 54.00 68.20 54.00

Margin
(dB)
-21.52 -16.64 -27.84 -17.21 -23.95 -19.13 -21.83 -17.39 -21.59 -17.92 -28.76 -19.50 -21.87 -18.29 -20.88 -17.35

Detect or
Type
PK AV PK AV PK AV PK AV PK AV PK AV PK AV PK AV

Polar (H/V)

Frequency (MHz)

Meter Reading
(dBuV)

V 10400.00 50.14 V 10400.00 41.15 V 15600.00 49.60 V 15600.00 39.84 V 20800.00 60.63 V 20800.00 49.90 V 26000.00 55.25 V 26000.00 46.55 H 10400.00 52.07 H 10400.00 41.45 H 15600.00 49.58 H 15600.00 39.84 H 20800.00 59.46 H 20800.00 47.58 H 26000.00 54.93 H 26000.00 45.66

Pre-

Cable Antenna Emission

amplifier Loss Factor

Level

(dB)

(dB)

(dB) (dBuV/m)

Middle Channel:5200MHz

46.2

8.27

38.5

50.71

46.20

8.27 38.50

41.72

46.30 10.35 38.40

52.05

46.30 10.35 38.40

42.29

57.40 11.93 37.80

52.96

57.40 11.93 37.80

42.23

56.50 13.45 39.80

52.00

56.50 13.45 39.80

43.30

46.20

8.27 38.50

52.64

46.20

8.27 38.50

42.02

46.30 10.35 38.40

52.03

46.30 10.35 38.40

42.29

57.40 11.93 37.80

51.79

57.40 11.93 37.80

39.91

56.50 13.45 39.80

51.68

56.50 13.45 39.80

42.41

Limits
(dBuV/m)
68.20 54.00 74.00 54.00 68.20 54.00 68.20 54.00 68.20 54.00 74.00 54.00 68.20 54.00 68.20 54.00

Margin Detect or
(dB) Type
-17.49 PK -12.28 AV -21.95 PK -11.71 AV -15.24 PK -11.77 AV -16.20 PK -10.70 AV -15.56 PK -11.98 AV -21.97 PK -11.71 AV -16.41 PK -14.09 AV -16.52 PK -11.59 AV

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 45 of 61

Report No.: ET-22092019E03

-

Polar (H/V)
V V V V V V V V H H H H H H H H

Frequency
(MHz)
10480.00 10480.00 15720.00 15720.00 20960.00 20960.00 26200.00 26200.00 10480.00 10480.00 15720.00 15720.00 20960.00 20960.00 26200.00 26200.00

Meter Reading
(dBuV)
47.45 36.75 44.85 34.32 55.66 46.49 51.37 41.28 47.71 36.75 45.20 34.43 55.85 46.38 51.05 40.62

Pre- Cable Antenna Emission

amplifier Loss Factor

Level

(dB)
46.20 46.20 46.30 46.30 57.40 57.40 56.50 56.50 46.20 46.20 46.30 46.30 57.40 57.40 56.50 56.50

(dB)

(dB) (dBuV/m)

High Channel:5240MHz

8.27 38.60

48.12

8.27 38.60

37.42

10.35 38.40

47.30

10.35 38.40

36.77

11.93 37.50

47.69

11.93 37.50

38.52

13.45 40.10

48.42

13.45 40.10

38.33

8.27 38.60

48.38

8.27 38.60

37.42

10.35 38.40

47.65

10.35 38.40

36.88

11.93 37.50

47.88

11.93 37.50

38.41

13.45 40.10

48.10

13.45 40.10

37.67

Limits
(dBuV/m)
68.20 54.00 74.00 54.00 68.20 54.00 68.20 54.00 68.20 54.00 74.00 54.00 68.20 54.00 68.20 54.00

Margin
(dB)
-20.08 -16.58 -26.70 -17.23 -20.51 -15.48 -19.78 -15.67 -19.82 -16.58 -26.35 -17.12 -20.32 -15.59 -20.10 -16.33

Detect or
Type
PK AV PK AV PK AV PK AV PK AV PK AV PK AV PK AV

Remark: 1. Emission Level = Meter Reading + Antenna Factor + Cable Loss ­ Pre-amplifier, Margin= Emission Level - Limit 2. If peak below the average limit, the average emission was no test. 3. The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible value has no need to be reported. 4. The worst mode is 802.11n20, only the worst data is recorded.

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 46 of 61

Report No.: ET-22092019E03

-

Temperature Pressure Test Mode 

25.4 1010 hPa 5.8G TX- 802.11n20

Relative Humidity 47%

Test Voltage 

AC 120V

Polar Frequency (H/V)
(MHz)
V 11490.00 V 11490.00 V 17235.00 V 17235.00 V 22980.00 V 22980.00 V 28725.00 V 28725.00 H 11490.00 H 11490.00 H 17235.00 H 17235.00 H 22980.00 H 22980.00 H 28725.00 H 28725.00

Meter Readi g
(dBuV)
49.44 40.37 46.74 38.63 56.44 47.55 52.89 43.45 49.96 40.17 47.87 39.10 58.89 47.30 55.08 44.15

Preamplifier

802.11n20
Cable Antenn Loss Factor

Emission Level

(dB)

(dB)

(dB) (dBuV/m)

Low Channel:5745MHz 46.10 8.77 39.10 46.10 8.77 39.10 47.60 11.10 38.70 47.60 11.10 38.70 56.90 12.73 37.70 56.90 12.73 37.70 55.60 14.25 40.30 55.60 14.25 40.30 46.10 8.77 39.10 46.10 8.77 39.10 47.60 11.10 38.70 47.60 11.10 38.70 56.90 12.73 37.70 56.90 12.73 37.70 55.60 14.25 40.30 55.60 14.25 40.30

51.21 42.14 48.94 40.83 49.97 41.08 51.84 42.40 51.73 41.94 50.07 41.30 52.42 40.83 54.03 43.10

Limits
(dBuV/m)
74.00 54.00 68.20 54.00 74.00 54.00 68.20 54.00 74.00 54.00 68.20 54.00 74.00 54.00 68.20 54.00

Margin
(dB)
-22.79 -11.86 -19.26 -13.17 -24.03 -12.92 -16.36 -11.60 -22.27 -12.06 -18.13 -12.70 -21.58 -13.17 -14.17 -10.90

Detect or
Typ
PK AV PK AV PK AV PK AV PK AV PK AV PK AV PK AV

Polar (H/V)

Frequency (MHz)

Meter Reading
(dBuV)

V 11570.00 39.15 V 11570.00 30.95 V 17355.00 38.23 V 17355.00 30.87 V 23140.00 45.76 V 23140.00 37.70 V 28925.00 42.14 V 28925.00 34.78 H 11570.00 40.73 H 11570.00 32.02 H 17355.00 37.92 H 17355.00 30.39 H 23140.00 46.57 H 23140.00 38.87 H 28925.00 43.53 H 28925.00 35.51

Pre- Cable Antenna Emission

amplifier Loss Factor

Level

(dB)

(dB)

(dB) (dBuV/m)

Middle Channel:5785MHz

46.10

8.77

39.10

40.92

46.10

8.77

39.10

32.72

47.70 11.10 38.40

40.03

47.70 11.10 38.40

32.67

56.90 12.73 37.80

39.39

56.90 12.73 37.80

31.33

55.60 14.25 40.50

41.29

55.60 14.25 40.50

33.93

46.10

8.77

39.10

42.50

46.10

8.77

39.10

33.79

47.70 11.10 38.40

39.72

47.70 11.10 38.40

32.19

56.90 12.73 37.80

40.20

56.90 12.73 37.80

32.50

55.60 14.25 40.50

42.68

55.60 14.25 40.50

34.66

Limits
(dBuV/m)
74.00 54.00 68.20 54.00 74.00 54.00 68.20 54.00 74.00 54.00 68.20 54.00 74.00 54.00 68.20 54.00

Margin
(dB)
-33.08 -21.28 -28.17 -21.33 -34.61 -22.67 -26.91 -20.07 -31.50 -20.21 -28.48 -21.81 -33.80 -21.50 -25.52 -19.34

Detect or
Type
PK AV PK AV PK AV PK AV PK AV PK AV PK AV PK AV

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 47 of 61

Report No.: ET-22092019E03

-

Polar (H/V)
V V V V V V V V H H H H H H H H

Frequency
(MHz)
11650.00 11650.00 17475.00 17475.00 23300.00 23300.00 29125.00 29125.00 11650.00 11650.00 17475.00 17475.00 23300.00 23300.00 29125.00 29125.00

Meter Reading
(dBuV)
44.73 35.83 42.64 35.13 52.12 42.92 48.92 40.21 46.69 38.18 43.83 36.38 53.50 44.33 49.95 40.94

Pre- Cable Antenna Emission

amplifier Loss Factor

Level

(dB)

(dB)

(dB) (dBuV/m)

High Channel:5825MHz 46.10 8.77 39.10 46.10 8.77 39.10 47.90 11.23 38.90 47.90 11.23 38.90 57.10 12.73 37.80 57.10 12.73 37.80 55.80 14.25 40.50 55.80 14.25 40.50 46.10 8.77 39.10 46.10 8.77 39.10 47.90 11.23 38.90 47.90 11.23 38.90 57.10 12.73 37.80 57.10 12.73 37.80 55.80 14.25 40.50 55.80 14.25 40.50

46.50 37.60 44.87 37.36 45.55 36.35 47.87 39.16 48.46 39.95 46.06 38.61 46.93 37.76 48.90 39.89

Limits
(dBuV/m)
74.00 54.00 68.20 54.00 68.20 54.00 68.20 54.00 74.00 54.00 68.20 54.00 68.20 54.00 68.20 54.00

Margin Detect or
(dB) Type
-27.50 PK -16.40 AV -23.33 PK -16.64 AV -22.65 PK -17.65 AV -20.33 PK -14.84 AV -25.54 PK -14.05 AV -22.14 PK -15.39 AV -21.27 PK -16.24 AV -19.30 PK -14.11 AV

Remark: 1. Emission Level = Meter Reading + Antenna Factor + Cable Loss ­ Pre-amplifier, Margin= Emission Level - Limit 2. If peak below the average limit, the average emission was no test. 3. The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible value has no need to be reported. 4. The worst mode is 802.11n20, only the worst data is recorded.

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 48 of 61

Report No.: ET-22092019E03

-

4.7.2 Conducted Emission Method

Test Requirement: Test Method: Limit: Test setup:

FCC Part15 C Section 15.209, Part 15E Section 15.407(b)(4) ANSI C63.10:2013 -27dBm/MHz

Test Instruments: Test mode: Test results:

Refer to section 3.0 for details Refer to section 2.2 for details Pass

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 49 of 61 -

5180-5240MHz 802.11a on channel 36

Test Plot

Report No.: ET-22092019E03 802.11a on channel 40

802.11a on channel 48

802.11n20 on channel 36

802.11n20 on channel 40

802.11n20 on channel 48

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 50 of 61

Report No.: ET-22092019E03

-

802.11ac20 on channel 36

Test Plot

802.11ac20 on channel 40

802.11ac20 on channel 48

802.11n40 on channel 38

802.11n40 on channel 46

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 51 of 61

Report No.: ET-22092019E03

-

802.11ac40 on channel 38

Test Plot

802.11ac40 on channel 46

802.11ac80 on channel 42

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 52 of 61 -

5745-5825MHz 802.11a on channel 149

Test Plot

Report No.: ET-22092019E03 802.11a on channel 157

802.11a on channel 165

802.11n20 on channel 149

802.11n20 on channel 157

802.11n20 on channel 165

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 53 of 61

Report No.: ET-22092019E03

-

802.11ac20 on channel 149

Test Plot

802.11ac20 on channel 157

802.11ac20 on channel 165

802.11n40 on channel 151

802.11n40 on channel 159

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 54 of 61

Report No.: ET-22092019E03

-

802.11ac40 on channel 151

Test Plot

802.11ac40 on channel 159

802.11ac80 on channel 155

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 55 of 61

Report No.: ET-22092019E03

-

4.8 Frequency stability
Test Requirement: Test Method: Limit: Test Procedure:
Test setup:

FCC Part15 C Section 15.407(g)
ANSI C63.10:2013, FCC Part 2.1055
Manufactures of U-NII devices are responsible for ensuring frequency stability such that an emission is maintained within the band of operation under all conditions of normal operation as specified
a. The EUT was placed inside the environmental test chamber and powered by nominal DC voltage.
b. Turn the EUT on and couple its output to a spectrum analyzer. c. Turn the EUT off and set the chamber to the highest temperature
specified. d. Allow sufficient time (approximately 30 min) for the temperature of the
chamber to stabilize, turn the EUT on and measure the operating frequency after 2, 5, and 10 Minutes. e. Repeat step 2 and 3 with the temperature chamber set to the lowest temperature. f. The test chamber was allowed to stabilize at +20 degree C for a minimum of 30 Minute s. The supply voltage was then adjusted on the EUT from 85% to
115% and the frequency record.

Test Instruments: Test mode: Test results:

Refer to section 3.0 for details Refer to section 2.2 for details Pass

Remark: Set the EUT transmits at un-modulation mode to test frequency stability.

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 56 of 61

Report No.: ET-22092019E03

-

Measurement data:

Temp. (°C) -30 -20 -10 0 10

Operating Frequency
(MHz)
5180 5190 5200 5210 5220 5230 5240 5180 5190 5200 5210 5220 5230 5240 5180 5190 5200 5210 5220 5230 5240 5180 5190 5200 5210 5220 5230 5240 5180 5190 5200 5210 5220 5230 5240

Frequency stability versus Temp.

Power Supply: AC120V

0 minute

2 minute

Measured Frequency
(MHz)

Measured Frequency
(MHz)

5179.998

5180.076

5189.994

5199.950

5199.989

5199.975

5209.995

5209.953

5219.990

5219.968

5229.988

5229.961

5239.961

5239.969

5179.989

5179.952

5189.980

5189.942

5199.988

5199.950

5209.980

5209.942

5220.001

5219.963

5229.979

5229.941

5239.997

5239.959

5179.998

5179.961

5189.994

5189.956

5199.989

5199.951

5209.995

5209.957

5219.990

5219.952

5229.988

5229.950

5239.961

5239.923

5179.775

5179.940

5199.947

5189.950

5199.945

5199.941

5210.000

5209.942

5219.989

5219.949

5229.976

5229.967

5239.993

5239.939

5179.977

5179.952

5189.988

5189.942

5199.979

5199.950

5209.980

5209.942

5219.987

5219.963

5230.005

5229.941

5239.990

5239.959

5 minute Measured Frequency
(MHz)
5179.798 5199.672 5199.697 5209.674 5219.689 5229.681 5239.689 5179.683 5189.682 5199.675 5209.664 5219.674 5299.667 5239.675 5179.662 5189.673 5199.663 5209.663 5219.670 5229.687 5239.659 5179.674 5189.665 5199.672 5209.663 5219.684 5229.661 5239.679 5179.683 5189.679 5199.673 5209.678 5219.673 5229.670 5239.643

10 minute Measured Frequency
(MHz)
5179.927 5189.938 5199.929 5209.930 5219.936 5229.954 5239.939 5179.948 5189.944 5199.939 5209.945 5219.939 5229.937 5239.910 5179.927 5189.938 5199.929 5209.930 5219.936 5229.954 5239.926 5179.938 5189.939 5199.930 5299.937 5219.929 5229.950 5239.928 5179.939 5189.930 5199.938 5209.930 5219.950 5229.928 5239.946

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

20 30 40 50

- Page 57 of 61

Report No.: ET-22092019E03

5180 5190 5200 5210 5220 5230 5240 5180 5190 5200 5210 5220 5230 5240 5180 5190 5200 5210 5220 5230 5240 5180 5190 5200 5210 5220 5230 5240

5180.002 5189.998 5199.993 5209.999 5219.994 5229.992 5239.965 5179.981 5189.992 5199.983 5209.984 5219.991 5230.009 5239.981 5179.993 5189.984 5199.992 5209.984 5220.005 5229.983 5240.001 5179.993 5189.984 5199.992 5209.984 5220.005 5229.983 5240.001

5179.992 5189.993 5199.984 5299.992 5219.984 5230.005 5239.983 5179.993 5189.984 5199.992 5209.984 5220.005 5229.983 5240.001 5179.992 5189.993 5199.984 5299.992 5219.984 5230.005 5239.983 5179.993 5189.984 5199.992 5209.984 5220.005 5229.983 5240.001

5179.985 5189.976 5199.984 5209.976 5219.997 5229.975 5239.993 5179.985 5189.976 5199.984 5209.976 5219.997 5229.975 5239.993 5179.771 5199.943 5199.941 5209.996 5219.985 5229.972 5239.989 5179.985 5189.976 5199.984 5209.976 5219.997 5229.975 5239.993

5179.936 5189.966 5199.991 5209.975 5219.966 5229.994 5239.982 5179.984 5179.984 5189.980 5199.975 5209.981 5219.976 5229.974 5179.963 5189.974 5199.965 5209.966 5219.973 5229.991 5239.963 5179.936 5189.966 5199.991 5209.975 5219.966 5229.994 5239.982

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 58 of 61

Report No.: ET-22092019E03

-

Power Supply (VAC) 102
120
138

Operating Frequency
(MHz)
5180 5190 5200 5210 5220 5230 5240 5180 5190 5200 5210 5220 5230 5240 5180 5190 5200 5210 5220 5230 5240

Frequency stability versus Voltage

Temperature: 25°C

0 minute

2 minute

Measured Frequency
(MHz)

Measured Frequency
(MHz)

5180.002

5180.116

5189.998

5199.989

5199.993

5200.017

5209.999

5209.995

5219.994

5220.010

5229.992

5230.003

5239.965

5240.011

5179.988

5180.011

5189.984

5180.117

5199.992

5199.992

5209.985

5210.017

5220.005

5219.995

5229.983

5230.010

5240.001

5240.003

5180.002

5180.002

5189.998

5189.998

5199.993

5199.993

5209.999

5209.999

5219.994

5219.994

5229.992 5239.965

5229.992 5239.965

5 minute Measured Frequency
(MHz)
5179.985 5189.976 5199.984 5209.976 5219.997 5229.975 5239.989 5179.984 5189.985 5199.976 5299.984 5219.976 5229.996 5239.975 5179.973 5189.984 5199.975 5209.976 5219.983 5230.001 5239.973

10 minute Measured Frequency
(MHz)
5180.099 5199.974 5199.999 5209.977 5219.992 5229.985 5239.993 5179.984 5189.983 5199.977 5209.967 5219.977 5299.975 5239.979 5179.963 5189.974 5199.964 5209.966 5219.973 5229.996 5239.963

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 59 of 61

Report No.: ET-22092019E03

-

Temp. (°C) -30 -20 -10 0 10 20 30 40

Operating Frequency
(MHz) 5745 5755 5775 5785 5795 5825 5745 5755 5775 5785 5795 5825 5745 5755 5775 5785 5795 5825 5745 5755 5775 5785 5795 5825 5745 5755 5775 5785 5795 5825 5745 5755 5775 5785 5795 5825 5745 5755 5775 5785 5795 5825 5745 5755 5775 5785

Frequency stability versus Temp.

Power Supply: AC 120V

0 minute

2 minute

5 minute

Measured

Measured

Measured

Frequency (MHz) Frequency (MHz) Frequency (MHz)

5744.979

5744.985

5744.977

5754.989

5754.992

5754.984

5775.010

5774.984

5775.001

5784.986

5784.976

5784.977

5794.982

5794.983

5794.973

5824.980

5824.912

5824.976

5744.976

5744.996

5744.971

5754.991

5754.998

5754.996

5774.990

5775.001

5774.977

5784.993

5784.993

5784.986

5795.003

5794.984

5794.984

5824.985

5824.993

5824.994

5744.986

5744.986

5744.987

5755.012

5754.993

5754.989

5775.008

5775.010

5774.992

5784.992

5784.986

5784.984

5794.981

5794.982

5794.975

5824.916

5824.984

5824.984

5744.980

5744.975

5744.987

5755.005

5754.991

5754.989

5774.986

5774.990

5774.992

5784.995

5784.993

5784.984

5794.993

5795.006

5794.975

5825.003

5824.985

5824.984

5744.980

5744.985

5744.976

5755.005

5755.002

5754.983

5774.986

5775.003

5774.975

5784.995

5784.985

5784.967

5794.993

5795.002

5794.974

5825.003

5825.000

5824.903

5744.996

5745.010

5744.985

5755.010

5754.982

5755.001

5774.995

5775.005

5774.986

5784.982

5785.005

5784.973

5794.976

5794.996

5794.967

5825.010

5825.011

5825.001

5744.986

5744.996

5744.970

5754.993

5754.998

5754.993

5775.010

5775.001

5774.994

5784.986

5784.993

5784.976

5794.982

5794.984

5794.993

5824.985

5824.993

5824.991

5744.996

5744.980

5744.987

5755.010

5755.005

5754.989

5774.995

5774.986

5774.992

5784.982

5784.995

5784.984

10 minute Measured Frequency (MHz) 5744.966 5754.955 5774.966 5784.973 5794.991 5824.983 5744.977 5754.991 5774.976 5784.963 5794.957 5824.991 5744.596 5754.980 5774.981 5784.984 5794.967 5824.963 5744.967 5754.993 5774.989 5784.973 5794.962 5824.897 5744.962 5754.974 5774.991 5784.967 5794.963 5824.966 5744.966 5754.985 5774.965 5784.992 5794.984 5824.993 5744.991 5754.963 5774.986 5784.986 5794.977 5824.992 5744.960 5754.993 5774.989 5784.973

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 60 of 61

Report No.: ET-22092019E03

-

5795

5825

5745

5755

50

5775 5785

5795

5825

5794.976 5825.010 5744.996 5754.990 5774.995 5784.982 5794.976 5825.010

5794.993 5825.003 5745.010 5754.982 5775.005 5785.005 5794.995 5825.015

5794.975 5824.984 5744.987 5755.000 5774.986 5784.973 5794.967 5825.001

5794.962 5824.897 5744.966 5754.985 5774.965 5784.993 5794.984 5824.993

Power Supply (VAC)
102
120
138

Operating Frequency
(MHz) 5745 5755 5775 5785 5795 5825 5745 5755 5775 5785 5795 5825 5745 5755 5775 5785 5795 5825

Frequency stability versus Voltage

Temperature: 25°C

0 minute

2 minute

5 minute

Measured

Measured

Measured

Frequency (MHz) Frequency (MHz) Frequency (MHz)

5744.975

5744.985

5744.976

5754.991

5754.992

5754.993

5774.990

5774.984

5774.994

5784.993

5784.976

5784.976

5795.004

5794.983

5794.994

5824.985

5824.912

5824.991

5744.975

5744.996

5744.971

5754.991

5754.998

5754.996

5774.990

5775.001

5774.977

5784.993

5784.993

5784.986

5795.000

5794.984

5794.984

5824.985

5824.993

5824.994

5744.996

5745.009

5744.987

5755.010

5754.982

5755.001

5774.995

5775.005

5774.986

5784.982

5785.005

5784.973

5794.976

5794.996

5794.967

5825.010

5825.011

5825.001

10 minute Measured Frequency (MHz) 5744.961 5754.986 5774.967 5784.976 5794.974 5824.984 5744.977 5754.991 5774.976 5784.963 5794.957 5824.991 5744.966 5754.985 5774.965 5784.992 5794.984 5824.993

Tel:(86-755) 85259392

Email:[email protected]

Web: www.etrlab.cn

No.103, No.10, Phase I, Zone 3, Xinxing Industrial Park, Xinhe, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

- Page 61 of 61 -
5 Test Setup Photo
Reference to the appendix I for details.
6 EUT Constructional Details
Reference to the appendix II for details.
------END------