EMC Test Report
David Schramm
SAR Exemption
Bright Uro Inc GUS1000 Sensor 2BHMUGUS1000 2BHMUGUS1000 gus1000
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 5 Pages, 539.11KB
Document DEVICE REPORTGetApplicationAttachment.html?id=8199446Test Report Number: 5079617EMC09 Rev.1 Bright Uro / GUS-M-1000/GUS-F-1000 Page: 1 of 5 RF Exposure Report Project Number: 5079617 Report Number: 5079617EMC09 Offer Number: SUW-202212003799 Revision Level: 1 Client: Bright Uro Equipment Under Test: Wireless, Catheter-Free, Urodynamic Monitoring System Model Name: Atusa Male Sensor Model Number: GUS-M-1000 Referenced Model: Atusa Female Sensor: GUS-F-1000 FCC ID: 2BHMUGUS1000 Module Model: nRF52811 Applicable Standards: 47 CFR §§ 2.1093 (Portable) FCC KDB 447498 D01 General RF Exposure Guidance v06 Report issued on: 30 March 2024 Report issued on: 07 April 2025 Result: Exempt from SAR evaluation FOR THE SCOPE OF ACCREDITATION UNDER CERTIFICATE NUMBER: 3212.01 This report must not be used by the client to claim product certification, approval, or endorsement by A2LA, NIST, or any agency of the Federal Government. Prepared by: Daniel Alvarez, RF/EMC Sr. Staff Engineer Reviewed by: Stephen Whalen, SAR/EMC Manager Remarks: This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com//en/Terms-and-Conditions.aspx. And for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/terms-e-document.aspx. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company's findings at the time of its intervention only and within the limits of Client's instructions, if any. The Company's sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for a maximum of 30 days only. Test Report Number: 5079617EMC09 Rev.1 Bright Uro / GUS-M-1000/GUS-F-1000 Page: 2 of 5 TABLE OF CONTENTS 1 GENERAL INFORMATION............................................................................................................................................. 3 1.1 CLIENT INFORMATION ................................................................................................................................................... 3 1.2 TEST LABORATORY ....................................................................................................................................................... 3 1.3 GENERAL INFORMATION OF EUT .................................................................................................................................. 3 1.4 SEPARATION DISTANCE................................................................................................................................................. 3 2 SAR EXCLUSION CALCULATIONS ............................................................................................................................. 4 3 REVISION HISTORY ........................................................................................................................................................ 5 SGS North America Inc. Connectivity & Products 620 Old Peachtree Road NW, Suite 100, Suwanee, GA 30024 t (770) 570-1800 www.sgs.com Member of the SGS Group (SGS SA) 1 General Information Test Report Number: 5079617EMC09 Rev.1 Bright Uro / GUS-M-1000/GUS-F-1000 Page: 3 of 5 1.1 Client Information Name: Bright Uro, Inc. Address: 3 Goddard City, State, Zip, Country: Irvine, CA 92618 USA 1.2 Test Laboratory Name: SGS North America, Inc. Address: 620 Old Peachtree Road NW, Suite 100 City, State, Zip, Country: Suwanee, GA 30024, USA Accrediting Body: Type of lab: Certificate Number: FCC Designation Number: A2LA Testing Laboratory 3212.01 US1126 1.3 General Information of EUT Type of Product: Model Name: Model Number: Referenced Model: Serial Number: Module Models: Wireless, Catheter-Free, Urodynamic Monitoring System Atusa Male Sensor GUS-M-1000 Atusa Female Sensor: GUS-F-1000 (For reference only - Not Tested) DV0013 (Conducted Sample) nRF52811 Frequency Range: Data Modes: Antenna: Max Conducted Output Power: 2402 2480 MHz Bluetooth Low Energy (BLE1M GFSK) Internal PCB Trace (0.5 dBi gain) * Bluetooth LE: -0.39dBm Sample Received Date: 13 November 2023, 15 March 2024 Dates of testing: 14 November 2023 to 15 March 2024 *Data was not measured by SGS laboratory and therefore not responsible for accuracy. Data obtained via customer, specification sheet, previous regulatory filing or other. 1.4 Separation Distance The closest exposure distance occurs when the sensor is inserted into the body. For this reason, the closest separation distance of 5mm was used to calculate the SAR exemption. SGS North America Inc. Connectivity & Products 620 Old Peachtree Road NW, Suite 100, Suwanee, GA 30024 t (770) 570-1800 www.sgs.com Member of the SGS Group (SGS SA) Test Report Number: 5079617EMC09 Rev.1 Bright Uro / GUS-M-1000/GUS-F-1000 Page: 4 of 5 2 SAR Exclusion Calculations The highest output power in conjunction with the Upper and Lower frequency boundaries have been used to demonstrate compliance for Bluetooth transmission mode. Simultaneous transmission is not possible. The EUT is considered a body application. Bluetooth LE (FCC ID: 2BHMUGUS1000) 447498 D01 General RF Exposure Guidance v06 SAR test exclusion calculations Section 4.3: General SAR test exclusion guidance / Section 4.3.1: Standalone SAR test exclusion considerations Max Power: Duty Cycle: Min separation distance: Frequency, f: Input -1.47 100.0% 5 2402 Select Units dBm mm MHz Unit correction 0.71285303 1 <== Source based time average duty cycle 5 2402 100 Value reference Number v1 v2 v3 Values used for Calculation 1.000 mW 5 mm 1.550 Reference number definition [max. power of channel, including tune-up tolerance, mW] 'Rounded to nearest mW [min. test separation distance, mm] 'Rounded to nearest mm [f(GHz)] a) For 100 MHz to 6 GHz and test separation distances 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [f(GHz)] 3.0 for 1-g SAR, and 7.5 for 10-g extremity SAR, Exclusion Calculation(1g): 0.3100 number <== [v2 / v3] must be less than 3 Exclusion Calculation(10g): 0.3100 number <== [v2 / v3] must be less than 7.5 Conclusions (Body): The EUT max power is BELOW the threshold. SAR Testing is NOT required for Body applications Conclusions (Extremity): The EUT max power is BELOW the threshold. SAR Testing is NOT required for Extremity applications 447498 D01 General RF Exposure Guidance v06 SAR test exclusion calculations Section 4.3: General SAR test exclusion guidance / Section 4.3.1: Standalone SAR test exclusion considerations Max Power: Duty Cycle: Min separation distance: Frequency, f: Input -0.39 100.0% 5 2480 Select Units dBm mm MHz Unit correction 0.914113241 1 <== Source based time average duty cycle 5 2480 100 Value reference Number v1 v2 v3 Values used for Calculation 1.000 mW 5 mm 1.575 Reference number definition [max. power of channel, including tune-up tolerance, mW] 'Rounded to nearest mW [min. test separation distance, mm] 'Rounded to nearest mm [f(GHz)] a) For 100 MHz to 6 GHz and test separation distances 50 mm, the 1-g and 10-g SAR test exclusion thresholds are determined by the following: [(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)] · [f(GHz)] 3.0 for 1-g SAR, and 7.5 for 10-g extremity SAR, Exclusion Calculation(1g): 0.3150 number <== [v2 / v3] must be less than 3 Exclusion Calculation(10g): 0.3150 number <== [v2 / v3] must be less than 7.5 Conclusions (Body): The EUT max power is BELOW the threshold. SAR Testing is NOT required for Body applications Conclusions (Extremity): The EUT max power is BELOW the threshold. SAR Testing is NOT required for Extremity applications SGS North America Inc. Connectivity & Products 620 Old Peachtree Road NW, Suite 100, Suwanee, GA 30024 t (770) 570-1800 www.sgs.com Member of the SGS Group (SGS SA) Test Report Number: 5079617EMC09 Rev.1 Bright Uro / GUS-M-1000/GUS-F-1000 Page: 5 of 5 3 Revision History Revision Level 0 1 Description of changes Initial Release Sections 1.4 and 2 were updated Revision Date 30 March 2024 07 April 2025 SGS North America Inc. Connectivity & Products 620 Old Peachtree Road NW, Suite 100, Suwanee, GA 30024 t (770) 570-1800 www.sgs.com Member of the SGS Group (SGS SA)
Related FCC IDs:
- 2BHMUGUS1000 - Bright Uro Inc Sensor [GUS1000] Microsoft Word for Microsoft 365; modified using SignServer