Installation Instructions
"Kent Yu"
Installation Instructions - Beacon Lighting
LED T8 tube ... Thank you for purchasing this quality GE product. ... All wiring and installation of the light fitting must adhere to local and national ...
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 3 Pages, 578.02KB
Document DEVICE REPORT12038L-12046L IM ver1.1 2018-4-2 -LEDT8TUBE 002 121234Installation Instructions LED T8 tube SKU# 12038L,12039L,12040L,12041L,12042L,12043L,12044L,12045L,12046L Rated Voltage 220-240V~ 50Hz Thank you for purchasing this quality GE product. To ensure correct function and safety, please read and follow all instructions carefully before using the product. Please keep instructions for future reference. Warranty · This light fitting is covered by 3 years warranty. Please retain proof of purchase. · Warranty will be void if there is any damage due to improper usage or modification to the fitting. · This fitting is not suitable for use with dimmer switches. · Warranty will be void if the fitting is used on the same circuit which has a dimmer switch. · Failure to comply with the instructions in this manual may increase the risk of damage or injury and will void warranty. Installation requirements · Must be installed by a licensed electrician when retro fitting electronic ballasts. · All wiring and installation of the light fitting must adhere to local and national wiring rules. eg. AS/NZS 3000:2007/Amendment 2:2012 Electrical installations. If unsure, please contact a licensed electrician. · This lamp is not suitable for use in emergency luminairesdesigned for double capped fluorescent lamp/s. · This lamp is designed to fit standard IEC compliant G13 bi-pin lamp holders. · Check whether the fitting has been damaged during transport. Do not operate/install any product which appears damaged in any way. Return the complete product to the place of purchase for inspection, repair or replacement. · Ensure power to the circuit you are working on has been switched OFF before commencing any electrical work. Installation directions Packing list: 1. LED T8 tube 2. Replaced starter (Fuse for LED tube) 3. Starter holder 4. Warning sticker 5. User guide Use the tube with T8 bracket with electricballast WARNING: · A fuse shall be used to protect the lamp that is inadvertently installed against short circuit. The luminaire shall have a fuse replacement rating label (included). For fuse information please see the specification section. · The luminaire has been modified and cannot be operated with conventional fluorescent lamp any longer. Only the same type of LED tube can be replaced. · The manufacturer of the original luminaire will no longer be responsible for the compliance of the modified product. Any modifications made to the originalluminaire may alter the safety aspects of the original luminaire; hence compliance assessments of the original luminaire may no longer be applicable to themodified luminaire. 1 |Page v1.1 Installation Instructions · The supplied warning sticker MUST be placed on the luminaire and must be visible during lamp replacement. · The rating of the lamp must not exceed the maximum wattage of the lamp that it is intended to replace or the total wattage of the replacement lamps mustnot exceed the maximum wattage of the luminaire. INSTRUCTIONS: 1. Switch off power supply before re-wiring and installation. 2. Remove the conventional fluorescent tube. 3. Remove the electronic ballast. 4. Rewire the fixture as shown in the AFTER RETRO FIT circuit diagram below and connect theincludedstarter holder to a live wirein series. 5. Place the warning stickers provided in the visible locations. 6. Install the T8 LED tube, then fix thereplacementstarter into the starter holder. 7. Switch on the power supply. Using the Tube T8 bracket with iron coreballast WARNING: If the luminaire contains a compensating capacitor, please ensure it is removed from the circuit. INSTRUCTIONS: 1. Switch off power supply before installation. 2. Remove the conventional fluorescent tube. 3. Remove the starter. 4. Place the warning stickers provided in the visible locations. 5. Install the replacement starter supplied. 6. Install the T8 LED tube. 7. Switch on the power supply. 2 |Page v1.1 Installation Instructions Safety tips · Always ensure the power is OFF and the fitting has cooled down before performing any maintenance, cleaning, changing the globe or adjustment to the fitting. · To clean, wipe with a damp clean cloth. Never soak the fitting with water. Specifications SKU # 12038L 12039L 12040L 12041L 12042L 12043L 12044L 12045L 12046L Model # YKT8BFG2-FRF-23W YKT8BFG2-FRF-16W YKT8BFG2-FRF-9W Rated Voltage INPUT: 220-240V~ 50Hz Rated Wattage LED Fuse Information Weight 6500K, 2400 lm 23W 4000K, 2400 lm 3000K, 2200 lm 6500K, 1700 lm 16W 4000K, 1700 lm 3000K, 1550 lm 6500K, 920 lm 9W 4000K, 920 lm 3000K, 830 lm 250V HRC type, Max. 2A quick-acting type, only for protecting maximum two lamps 0.28kg 0.20kg 0.13kg Dimensions 27.8mm x 1513mm (D x C) 27.8mm x 1212.4mm (D x C) 27.8mm x 602.8mm (D x C) Nominal Wattage Cap Nominal Dimensions IP Rating The type of lamp it replaces 58W 36W G13 G13 26mm x 1500mm 26mm x 1200mm IP20 IP20 18W G13 26mm x 600mm IP20 GE is a trademark of General Electric Company and is under license by Light Source Solutions of 140 Fulton Drive Derrimut Vic 3030Australia 3 |Page v1.1Microsoft Word 2016