Installation Instructions

"Kent Yu"

Installation Instructions - Beacon Lighting

LED T8 tube ... Thank you for purchasing this quality GE product. ... All wiring and installation of the light fitting must adhere to local and national ...

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 3 Pages, 578.02KB

Document DEVICE REPORT12038L-12046L IM ver1.1 2018-4-2 -LEDT8TUBE 002 121234
Installation Instructions
LED T8 tube
SKU# 12038L,12039L,12040L,12041L,12042L,12043L,12044L,12045L,12046L Rated Voltage 220-240V~ 50Hz
Thank you for purchasing this quality GE product. To ensure correct function and safety, please read and follow all instructions carefully before using the product. Please keep instructions for future reference.
Warranty
· This light fitting is covered by 3 years warranty. Please retain proof of purchase. · Warranty will be void if there is any damage due to improper usage or modification to the fitting. · This fitting is not suitable for use with dimmer switches. · Warranty will be void if the fitting is used on the same circuit which has a dimmer switch. · Failure to comply with the instructions in this manual may increase the risk of damage or injury and will void
warranty.
Installation requirements
· Must be installed by a licensed electrician when retro fitting electronic ballasts. · All wiring and installation of the light fitting must adhere to local and national wiring rules. eg. AS/NZS
3000:2007/Amendment 2:2012 Electrical installations. If unsure, please contact a licensed electrician. · This lamp is not suitable for use in emergency luminairesdesigned for double capped fluorescent lamp/s. · This lamp is designed to fit standard IEC compliant G13 bi-pin lamp holders. · Check whether the fitting has been damaged during transport. Do not operate/install any product which appears
damaged in any way. Return the complete product to the place of purchase for inspection, repair or replacement. · Ensure power to the circuit you are working on has been switched OFF before commencing any electrical work.
Installation directions
Packing list: 1. LED T8 tube 2. Replaced starter (Fuse for LED tube) 3. Starter holder 4. Warning sticker 5. User guide

Use the tube with T8 bracket with electricballast

WARNING: · A fuse shall be used to protect the lamp that is inadvertently installed against short circuit. The luminaire
shall have a fuse replacement rating label (included). For fuse information please see the specification section. · The luminaire has been modified and cannot be operated with conventional fluorescent lamp any longer. Only the same type of LED tube can be replaced. · The manufacturer of the original luminaire will no longer be responsible for the compliance of the modified product. Any modifications made to the originalluminaire may alter the safety aspects of the original luminaire; hence compliance assessments of the original luminaire may no longer be applicable to themodified luminaire.

1 |Page

v1.1

Installation Instructions
· The supplied warning sticker MUST be placed on the luminaire and must be visible during lamp replacement. · The rating of the lamp must not exceed the maximum wattage of the lamp that it is intended to replace or
the total wattage of the replacement lamps mustnot exceed the maximum wattage of the luminaire.
INSTRUCTIONS: 1. Switch off power supply before re-wiring and installation. 2. Remove the conventional fluorescent tube. 3. Remove the electronic ballast. 4. Rewire the fixture as shown in the AFTER RETRO FIT circuit diagram below and connect theincludedstarter holder to a live wirein series. 5. Place the warning stickers provided in the visible locations. 6. Install the T8 LED tube, then fix thereplacementstarter into the starter holder. 7. Switch on the power supply.

Using the Tube T8 bracket with iron coreballast
WARNING: If the luminaire contains a compensating capacitor, please ensure it is removed from the circuit.
INSTRUCTIONS: 1. Switch off power supply before installation. 2. Remove the conventional fluorescent tube. 3. Remove the starter. 4. Place the warning stickers provided in the visible locations. 5. Install the replacement starter supplied. 6. Install the T8 LED tube. 7. Switch on the power supply.

2 |Page

v1.1

Installation Instructions

Safety tips
· Always ensure the power is OFF and the fitting has cooled down before performing any maintenance, cleaning, changing the globe or adjustment to the fitting.
· To clean, wipe with a damp clean cloth. Never soak the fitting with water.

Specifications

SKU #

12038L 12039L 12040L 12041L 12042L 12043L 12044L 12045L 12046L

Model #

YKT8BFG2-FRF-23W

YKT8BFG2-FRF-16W

YKT8BFG2-FRF-9W

Rated Voltage

INPUT: 220-240V~ 50Hz

Rated Wattage
LED
Fuse Information
Weight

6500K, 2400 lm

23W 4000K, 2400 lm

3000K, 2200 lm

6500K, 1700 lm

16W 4000K, 1700 lm

3000K, 1550 lm

6500K, 920 lm

9W 4000K, 920 lm

3000K, 830 lm

250V HRC type, Max. 2A quick-acting type, only for protecting maximum two lamps

0.28kg

0.20kg

0.13kg

Dimensions

27.8mm x 1513mm (D x C)

27.8mm x 1212.4mm (D x C)

27.8mm x 602.8mm (D x C)

Nominal Wattage
Cap Nominal Dimensions IP Rating

The type of lamp it replaces

58W

36W

G13

G13

26mm x 1500mm

26mm x 1200mm

IP20

IP20

18W G13 26mm x 600mm IP20

GE is a trademark of General Electric Company and is under license by Light Source Solutions of 140 Fulton Drive Derrimut Vic 3030Australia