RF EXPOSURE EVALUATION
zhaowen
18 Regular RFExp
ShenZhen YuYuanTong Technology Co.,Ltd REGULAR 2A863-REGULAR 2A863REGULAR regular
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 1 Pages, 142.84KB
Document DEVICE REPORTGetApplicationAttachment.html?id=6241563RF EXPOSURE EVALUATION FCC ID: 2A863-REGULAR According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency(RF) Radiation as specified in §1.1307(b): Routine SAR evaluation refers to that specifically required by §2.1093, using measurements or computer simulation. When routine SAR evaluation is not required, portable transmitters with output power greater than the applicable low threshold require SAR evaluation to qualify for TCB approval. Channel (MHz) 2402 2441 2480 2402 2441 2480 Maximum output power (dBm) -0.68 -0.72 -1.06 0.17 -0.08 -0.40 Tune up tolerance (dBm) Max Tune Up Distance Calculation Power (dBm) (mm) results -0.68 ±1 -0.72 ±1 -1.06 ±1 0.17 ±1 -0.08 ±1 -0.40 ±1 0.32 0.28 -0.06 1.17 0.92 0.60 5 0.334 5 0.333 5 0.311 5 0.406 5 0.386 5 0.362 Limit 3 3 3 3 3 3 Operating Mode GFSK /4-DQPSK Result: No Standalone SAR test is required.