MadgeTech LynxPro-VAX-60 Bluetooth Vaccine Data Logger with LCD and 60 mL glycol bottle, -4 to 140°F, 0.18°F
MadgeTech LynxPro Bluetooth Temperature Data Logger with LCD, -4 to 140°F, 0.18°F
MadgeTech LynxPro-RTD Bluetooth RTD Temperature Data Logger with LCD and RTD probe, -148 to 392°F, 0.18°F
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 16 Pages, 5.98MB
Document DEVICE REPORT902375-00-manualLynxPro User Guide Find Quality Products Online at: www.GlobalTestSupply.com [email protected] TABLE OF CONTENTS LynxPro Overview 03 App Overview 04 Home/Devices Page Add Devices Page Reports Page Top Navigation Bar Settings Device Main Page Device Settings Quick Start 12 With MadgeTech App Quick Start 13 With MadgeTech 4 Data Logger Software Battery Change Procedure Support 14-15 15 Tips & Troubleshooting 16 Find Quality Products Online at: www.GlobalTestSupply.com [email protected] LynxPro Overview Bluetooth Alarm Running USB Connect Battery Play Button LCD Screen Current Reading Bluetooth Button Battery Door Play Button: When device is in Manual Mode this button can be used to start the device or mark specific readings Bluetooth Button: Used to enable/disable Bluetooth broadcasting LCD Screen: Displays current status and readings Battery Door: User replaceable CR2450 battery Alarm: Alarm is activated Bluetooth: Visible when Bluetooth is turned on. Additional blinking arrows when connected to app. When connected to external power, Bluetooth will remain on Running: Will flash when actively running. Solid when waiting to start (manual mode) USB Connect: Connected via USB to power source Battery: Health monitor of the device battery Current Reading: The last reading the LynxPro has taken Find Quality Products Online at: www.GlobalTestSupply.com [email protected] App Overview Home/Devices Page Devices that you have previously claimed appear here. A quick overview of each device is provided. Serial Number: The non-editable serial number for the device. Device ID: The customizable name each device is given. This can be changed in the Device Settings page. Connection Level: The Bluetooth connection level to the device. In order to improve this, move your phone or tablet closer to the device. Current Status: The Current Status is color coded as: Gray: The device is out of range or the Bluetooth is not enabled Solid Yellow: The device is in range, but idle Blinking Green: The device is in range and set to Manual Start which requires starting either via the Play button on the device. To remove a device from your list, slide to the left. Green: The device is actively logging Red: The device has detected alarm conditions Find Quality Products Online at: www.GlobalTestSupply.com [email protected] Add Devices Page Devices that have Bluetooth enabled that have not previously been claimed by the current phone will appear here. If you do not see your device, move the phone closer to it. Click on a device to add it to your Home/Devices page. Reports Page Displays all previously created reports. Reports can be sorted based on date or utilize filtering as outlined below: Show All: Will display all currently available reports. Show Alarms: Will display only reports with data that has triggered alarms. Show PDF: Will display only reports saved as PDFs. Show .csv: Will display only reports saved as .csv files. Show SN: Filter by serial number/device ID Show Anomalies: Show only problem reports Show Not Shared: Show only files that have not been shared Reports highlighted in red contain an alarm condition. Reports with blue title are a .pdf, while green titles signify .csv files. Click on the report icon to see a report summary and graph. The green check mark on report indicates that the report has been shared. To share a report, click on the desired report. Determine whether to use defaults to send to contacts set in App Settings or Select App to share to other contact(s). To delete a report, slide left. Find Quality Products Online at: www.GlobalTestSupply.com [email protected] Top Navigation Bar Main Menu Clicking the main menu in the top left corner will launch the Main Menu. Help Launches a series of resources including User Guide, Online Support, FAQs, Licence Agreement, Privacy Policy, and a Contact Us link. Watch Launches the Devices (Watch) page. Add Launches the Add Devices page. Reports Launches the Reports page. Settings Launches general settings for the app. About Provides information regarding the current version of the app you are running. Quick Access Buttons Help Button Initiate in-app, on-page guided assistance. Help Button Quick Connect Button Enable or Disable Quick Connect. When Quick Connect is on and Bluetooth is enabled, the device will automatically connect and download readings when within range. If Automatic Report Generation and Automatic Report Sharing are also enabled, Quick Connect will automatically connect, download data, generate a report and share the report to the default contact. Quick Connect Button Find Quality Products Online at: www.GlobalTestSupply.com [email protected] Settings The App Settings screen allows preferences to be set for the app. General Settings Producer ID: A user-defined label on each report used to identify the associated person, device, or location Units: Select whether to display readings in Celsius or Fahrenheit. Time Format: Select whether to use a 12- or 24-hour clock. Date Format: Select between the Day-Month (DM) or Month-Day (MD) date format. Quick Connect: When Quick Connect is on and Bluetooth is enabled, the device will automatically connect and download readings when within range. If Automatic Report Generation and Automatic Report Sharing are also enabled, Quick Connect will automatically connect, download data, generate a report and share the report to the default contact. Quick Connect can also be toggled on or off using the `Q' button located in the top navigation. Audible Alerts: Enable or disable audible alarms. Pop-Up Hint Control: Tap Restore to restore all pop-up hints. Tap Hide to hide all pop-up hints. Report Settings Automatic Generation: Select whether a report is automatically created when a device is connected, either through Quick Connect or manual connection. Enabling this will automatically clear the device's readings and restart the device once the report has been generated. Automatic Report File Format: Select the desired format for automatically generated reports. Retention Period: Specify the number of days to retain a report before automatic deletion. Will only generate a warning. Will not do automatic deletion but will prompt the operator to do so. Share by SMS: Specify the number to receive reports. For nonautomatic report sharing, alternate numbers may be used. Share by Email: Specify the address to receive reports. For nonautomatic report sharing, alternate numbers may be used. Automatic Sharing: Automatically share report upon creation to the number and/or email above. Note that only successfully downloaded reports are shared automatically. Find Quality Products Online at: www.GlobalTestSupply.com [email protected] Notifications Settings Logger Checks Schedule: Select how frequently daily checks should be performed for VFC requirements Report Alert Time: Select the time checks should be completed at. For 12 hour checks, the Report Alert Time will be every 12 hours Prior Warning: Specify how long before the Report Alert Time a notification should be sent Repeat Warning: Specify how long after the initial warning all subsequent notification should be sent Calibration Period: Specify your calibration interval, as stated in your Standard Operating Procedure (SOP) Prior Warning: Specify how many days in advance you would like to receive a calibration reminder. Find Quality Products Online at: www.GlobalTestSupply.com [email protected] Device Main Page The device summary page gives an overview of the current status of the selected device. Device ID: The user set name of the device. Tap on the device to see the device specifications Reading Interval: The current reading rate of the device. Additionally, ETTF (estimated time to full) estimates the approximate amount of time the device can run with the current reading rate before the device memory is full. Number of Readings: The total number of readings currently stored on the device. Additionally, the percentage of how full the device's memory is provided. Status/Alarms: Provides the current status of the device as either Nominal (no alarm) or Alarmed (active alarm). Tap on an individual alarm to get details. Refresh Button: Used to update the data without having to exit and reenter the device main page. Graph: The Graph shows all data currently on the device. Tap the graph to expand view. Dotted lines represent times that have been Marked by pressing the Play button on the device. Minimum, Average and Maximum statistics are also provided for the current dataset. Device Control Buttons: Quick Start: Start the device with the current settings. Clear Alarm: Clear an active alarm on the device. Release: Will exit the page and remove the device from your Devices/Home Page. Report: Generate a report from the current data set. You will then be prompted to specify the report format, file name and the number and/or email address to automatically share to. Reports can also be shared from the Reports page after they are created. Find Quality Products Online at: www.GlobalTestSupply.com [email protected] Device Settings The Device Settings page includes all device-specific preferences. General Settings Serial Number: Displays the non-editable serial number assigned to the device. Firmware Revision: Displays the current firmware revision on the device. Device ID: Specify the desired name to be used on the device. Model: Displays the model of the current device. Last Start Date: Displays the last time the device was started. Readings: Displays the number of readings currently on the device. Maximum Readings: Displays the total number of readings the device can store. LCD Units: Specify whether the LCD should display readings in Celsius or Fahrenheit. Note this will only change the display on the LCD. To change the display in the app and reports, adjust in General App Settings. Battery Level: Displays the current battery level of the device. Last Calibration: Date the unit was last calibrated Load Profile: Access library of previously saved profiles. Alarm Settings Enable Alarm: Alarms must be enabled in order to edit alarm settings. Status: Display whether an alarm is currently active and allow you to Clear Alarm. High: Set the high threshold for triggering alarm. Low: Set the low threshold for triggering alarm. Delay: Specify the length of time the temperature and/or humidity must remain outside of the specified range before triggering an alarm. Cumulative Alarm Delay: Count the cumulative time from the start of record that the temperature and/or humidity is outside of the specified range to trigger an alarm. Find Quality Products Online at: www.GlobalTestSupply.com [email protected] Trigger Settings Trigger settings can be configured to allow a device to automatically begin and stop recording data when certain reading thresholds are reached. Triggers can be set in two modes: Window: Recording will begin when a reading is below the low setpoint, or above the high setpoint. Select Fill Memory on first trigger to continuously record until device memory is full. Alternately, specify the desired number of readings in the Trigger Sample Count field. Recording will stop after that number of readings until the setpoint is reached again. Two-Point: Set both high and low start/stop setpoints. To begin recording, a reading must be above the high setpoint or below the low setpoint. To stop recording, a reading must be below the high setpoint or above the low setpoint. Start/Stop Settings When starting a device to record data, several options and start methods are available. Start settings can be specified before deploying the device. Start Method: Now: Starts the device immediately. Delay: Specifies the exact time and day the device should start. Manual: Requires the Play button on the device to be pressed to start recording. Stop Method: Manual: Requires that the Stop Device button be pressed on the Device Summary Page. Automatic: Specifies the exact time and day the device should stop recording. Reading Interval: Specifies how often a reading should be taken and can be set from one reading every one second to one reading every 24-hours. Once you have configured settings, choose to either start your device, or save the settings to be applied to additional devices. Custom Start: Applies the settings to the currently connected device. Create Profile: Creates a saved profile of the current Trigger Settings and Start/Stop Settings so that they can be applied to additional devices. Once pressed, you will be prompted to name your profile. Find Quality Products Online at: www.GlobalTestSupply.com [email protected] Quick Start with MadgeTech App Install the MadgeTech Mobile App using one of the QR Codes below. A list of nearby devices will be presented. From this list, locate the LynxPro of interest and tap the desired device to add to your Devices/Home Page. Once installed, open the MT Mobile App. By default, you're presented with the Home Screen. This screen will typically show devices which have previously been established or connected to the phone. To find your device, navigate to the Add Device page. To connect to the device, click on it from the Devices/Home Page. Once on the Device Summary Page loads, click on the Gear icon to launch the Device Settings. Follow the navigation to set Alarms, Triggers and Start/Stop modes. To learn more about device settings, visit page 8. Ensure that Bluetooth is enabled on your smartphone, then press and hold the Bluetooth button on the LynxPro for 3-seconds until the Bluetooth logo appears in the upper left corner. When plugged into external power, Bluetooth will remain on. Bluetooth Logo Once devices settings have been configured, press the Custom Start button to save settings to the device. If Manual Start was selected, press and hold the Play Button on the device for 3 seconds to begin recording. Play Button Bluetooth Button Find Quality Products Online at: www.GlobalTestSupply.com [email protected] Quick Start with MadgeTech 4 Data Logger Software Download the MadgeTech 4 data Logger Software from the MadgTech Website. Once installed, open the application and connect the LynxPro device with a Micro USB cable, ensuring Bluetooth is disabled. Once connected, the LynxPro should be listed in the Connected Devices panel. Once you see the device, select it and click Custom Start to launch the Start Device window. Select start method, stop method and reading interval. Once preferences are set, click Start to start the device. If Manual Start was selected, the Play Button must be held for 3 seconds on the device to start recording. Find Quality Products Online at: www.GlobalTestSupply.com [email protected] Battery Change Procedure The LynxPro family of data loggers run on a CR2450 coin-cell battery, which is easy to find. These batteries are initially installed at the factory, but you can replace them yourself. The battery's status is shown on the LCD display. When you see four bars, it's a new or fully charged battery. As the battery's life decreases, you'll see fewer bars, and if there are no bars, you need to change the battery immediately. If the battery completely runs out (discharges fully), the logger will stop recording data. However, any data collected just before the battery failed will be saved. Even with an empty battery, you can still download data if you connect the logger to a PC. In this mode, the PC powers the logger, enabling communication. It's important to note that the LynxPro's battery can't be recharged. Once the device loses power, it will turn off. Servicing the battery is easy with the battery access port located on the back of the LynxPro. Battery Door Either by pinching the finger impressions, or through using a coin, rotate the battery plug counter clockwise by 45 degrees. Remove the plug, and the battery becomes exposed. Find Quality Products Online at: www.GlobalTestSupply.com [email protected] Remove the old battery and discard to an appropriate recycling system. With a new, fresh, CR2450 battery, position the battery with the "+" symbol up towards you. Deposit the battery into the LynxPro. You may find some reluctance due to a tight fit. The battery should be snug but not require significant force. Once inserted/centered, apply the battery plug and rotate 45 degrees to lock the plug into place. Find Quality Products Online at: www.GlobalTestSupply.com [email protected] Tips and Troubleshooting Unable to Find the Logger · Check for the Bluetooth indicator on the logger. If that is not present, hold down the Bluetooth button on the device until the indicator appears (about 2 seconds). · Make sure the logger is not connected to another app (phone). · Move the phone closer to the device. The maximum distance between the phone and the logger should be no more than 20 feet (6 meters). · It is recommended that the phone should have 4 to 5 bars for signal level indicator (blue signal level indicator) for reliable downloads. · If the device has already been added to the watch list (Devices Home Page) it should appear there and the signal level bars will turn blue if the logger is detected. Otherwise... · Check the add devices page and tap on the device to add it to the watch list. Then tap on the logger in the watch list to connect. Unable to Connect to the Logger · Check the add devices list to see if the device is appearing there and tap on the device to move it to the watch list on the devices (home) page. Then tap on the device in the watch list in order to connect to the logger. · If a device is removed from the watch list, either through sliding left on the watch list or removing the device directly on the Device main page, it will appear thereafter in the add devices list. This will reset the downloading indicator such that all of the data on the device will be downloaded by the app instead of resuming where it left off reading previously when the app reconnects. Anomalies Alarms, Alerts and Warnings · In the device main the Status/Alarms is nominally green indicating no reported issues. Otherwise the problems are color coded: Orange: Warning Red: Errors (Alarms and/or Alerts) · Tap on the entry to show a list of what was discovered. Within the list tap on a color-coded entry for specific details and explanations. Manual Start · If the app is connected to the logger when manually starting the logger then tap on the refresh button on the main page, after starting the logger, to see the logger's updated status. Power Issues · A warning will be generated when a low battery is detected. It is recommended that the battery be replaced before attempting to download data. USB/Bluetooth · MT4 will not connect to the logger via the USB until the Bluetooth is turned off. Press and hold the Bluetooth button on the logger until the Bluetooth icon disappears (about 2 seconds). · Refer to the MT4 user's guide for instructions on how to update the unit firmware. Problem Downloading the Data · If there is no new data available a notice is generated indicating that there is no new data to be downloaded. · Periodically due to interference or marginal proximity to the logger, a download may not complete fully. Cancel the download and attempt to download again. The app will resume the download where it left off. DOC-1435036-00 | REV 4 | 2023.12.8 Find Quality Products Online at: www.GlobalTestSupply.com [email protected]Adobe PDF library 9.00