VER SYSTEM ASSEMBLY - Jackson WWS

1-4-23-22-E 4 of 4 8. Tidy hoses by sliding them under clamps. 9. Locate wire connectors at top of VER system (near fans) and connect black wire and white wire …

1-4-23-22-E 4 of 4 8. Tidy hoses by sliding them under clamps. 9. Locate wire connectors at top of VER system (near fans) and connect black wire and white wire from machine control box (located in black cord routed from

VER SYSTEM ASSEMBLY

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 4 Pages, 792.79KB

Document DEVICE REPORTTempstar-HH-Heat-Recovery-Mounting-Installation-Instructions
VER SYSTEM ASSEMBLY
TEMPSTAR VER TEMPSTAR HH-E-VER

PURPOSE
The Ventless and Energy Recovery (VER) system is shipped in separate packaging and must be installed before proceeding with machine installation.

TOOLS REQUIRED
· 7/16 Wrench · 9/16 Wrench · Adjustable Wrench · Thread Tape

PREPARATION
1. Remove machine and VER system from packaging. 2. Ensure hoses are connected to VER system.
Long Red Hose

Short Red Hose

Blue Hose

Gauge Hose

PROCEDURE

1. Remove and keep four 1/4-20 bolts using 7/16 wrench. These are located at topleft and top-right on back of machine.

7/16 wrench used in this step. Keep hardware!
07610-004-23-22-E

1 of 4

VER SYSTEM ASSEMBLY

TEMPSTAR VER TEMPSTAR HH-E-VER

PROCEDURE

2. Lift VER system up and over lower air inlet, then align and slide into lower air inlet. VER system slides inside lower air inlet at the seam.

!
WARNING
WARNING! Use proper lifting techiques or use a lifting aid.

Lower Air Inlet
Seam

3. Re-install four 1/4-20 bolts removed in Step 1 with 7/16 wrench.

7/16 wrench used in this step.
Hardware kept used in this step.

4. Use 9/16 wrench to connect gauge hose to side of tee on plumbing from booster.

9/16 wrench used in this step.
Apply thread tape to threads of hose before connecting.
Hose is cut-to-length and will only reach intended
connection point.
07610-004-23-22-E

2 of 4

VER SYSTEM ASSEMBLY

TEMPSTAR VER TEMPSTAR HH-E-VER

PROCEDURE

5. Use adustable wrench to connect long red hose to top of tee on plumbing from booster.

Adjustable wrench used in this step.
Apply thread tape to threads of hose before connecting.
Hose is cut-to-length and will only reach intended
connection point.

6. Use adustable wrench to connect short red hose to rinse injector.
Adjustable wrench used in this step.
Apply thread tape to threads of hose before connecting.
Hose is cut-to-length and will only reach intended
connection point.
7. Use adustable wrench to connect blue hose to coupling on plumbing going to booster.

Adjustable wrench used in this step.
Apply thread tape to threads of hose before connecting.
Hose is cut-to-length and will only reach intended
connection point.
07610-004-23-22-E

3 of 4

VER SYSTEM ASSEMBLY

PROCEDURE

8. Tidy hoses by sliding them under clamps.

TEMPSTAR VER TEMPSTAR HH-E-VER

Black wire and white wire are shipped disconnected on end shown, but are already connected inside control box.

9. Locate wire connectors at top of VER system (near fans) and connect black wire and white wire from machine control box (located in black cord routed from control box), black in one connector and white in the other.

!
CAUTION
CAUTION! Fan wires must be connected to black wire and white wire before proceeding
with machine installation!

10. Tidy wires and lock them in place with p-clamp on top of VER system.

11. VER system is now assembled. Proceed with Step 2 of install guide that came with machine.

07610-004-23-22-E

4 of 4


Adobe PDF Library 15.0 Adobe InDesign 14.0 (Windows)

Search Any Device: