Date/Time: 1/13/2011 12:26:38 AM, Date/Time: 1/13/2011 12:35:24 AM

John

14040868 App B SAR System Check Plots

Apple Inc. E8147A SMARTPHONE BCG-E8147A BCGE8147A e8147a

Apple Inc. E8139A SMARTPHONE BCG-E8139A BCGE8139A e8139a

Apple Inc. E8146A SMARTPHONE BCG-E8146A BCGE8146A e8146a

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 38 Pages, 741.93KB

Document DEVICE REPORTGetApplicationAttachment.html?id=6103029
Test Laboratory: UL Verification Services Inc. SAR Lab A

Date/Time: 7/10/2022 10:49:27 AM

20220710_SystemPerformanceCheck-D1900V2 SN 5d163

Frequency: 1900 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C Medium parameters used: f = 1900 MHz;  = 1.453 S/m; r = 39.319;  = 1000 kg/m3 DASY5 Configuration: - Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg - Electronics: DAE4 Sn1546; Calibrated: 3/22/2022 - Probe: EX3DV4 - SN7501; ConvF(8.31, 8.31, 8.31) @ 1900 MHz; Calibrated: 3/25/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V8.0 (20deg probe tilt); Type: QD 000 P41 AA; Serial: 1948
Head/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 4.64 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 56.22 V/m; Power Drift = -0.11 dB Peak SAR (extrapolated) = 6.59 W/kg SAR(1 g) = 3.7 W/kg; SAR(10 g) = 1.98 W/kg Smallest distance from peaks to all points 3 dB below = 11.4 mm Ratio of SAR at M2 to SAR at M1 = 56.9% Maximum value of SAR (measured) = 4.91 W/kg

0 dB = 4.91 W/kg = 6.91 dBW/kg

Plot No. 1

Test Laboratory: UL Verification Services Inc. SAR Lab B

Date/Time: 7/17/2022 7:03:38 AM

20220717_SystemPerformanceCheck-D1750V2 SN 1077

Frequency: 1750 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 1750 MHz;  = 1.409 S/m; r = 39.593;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1258; Calibrated: 3/18/2022 - Probe: EX3DV4 - SN7498; ConvF(8.73, 8.73, 8.73) @ 1750 MHz; Calibrated: 3/24/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V8.0 (20deg probe tilt); Type: QD 000 P41 AA; Serial: 1956
Head/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 4.91 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 59.71 V/m; Power Drift = 0.03 dB Peak SAR (extrapolated) = 7.36 W/kg SAR(1 g) = 3.91 W/kg; SAR(10 g) = 2.06 W/kg Smallest distance from peaks to all points 3 dB below = 11 mm Ratio of SAR at M2 to SAR at M1 = 53.9% Maximum value of SAR (measured) = 5.27 W/kg

0 dB = 5.27 W/kg = 7.22 dBW/kg

Plot No. 2

Test Laboratory: UL Verification Services Inc. SAR Lab C

Date/Time: 7/10/2022 8:30:59 AM

20220710_SystemPerformanceCheck-D1900V2 SN 5d163

Frequency: 1900 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 1900 MHz;  = 1.423 S/m; r = 41.562;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1545; Calibrated: 2/23/2022 - Probe: EX3DV4 - SN7500; ConvF(8.1, 8.1, 8.1) @ 1900 MHz; Calibrated: 3/25/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V8.0 (20deg probe tilt); Type: QD 000 P41 AA; Serial: 1948
Head/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 4.45 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 56.33 V/m; Power Drift = 0.14 dB Peak SAR (extrapolated) = 7.00 W/kg SAR(1 g) = 3.78 W/kg; SAR(10 g) = 1.99 W/kg Smallest distance from peaks to all points 3 dB below = 11 mm Ratio of SAR at M2 to SAR at M1 = 54.8% Maximum value of SAR (measured) = 5.08 W/kg

0 dB = 5.08 W/kg = 7.06 dBW/kg

Plot No. 3

Test Laboratory: UL Verification Services Inc. SAR Lab C

Date/Time: 7/17/2022 6:23:47 AM

20220717_SystemPerformanceCheck-D1750V2 SN 1050

Frequency: 1750 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 1750 MHz;  = 1.395 S/m; r = 38.488;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1545; Calibrated: 2/23/2022 - Probe: EX3DV4 - SN7500; ConvF(8.42, 8.42, 8.42) @ 1750 MHz; Calibrated: 3/25/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V8.0 (20deg probe tilt); Type: QD 000 P41 AA; Serial: 1948
Head/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 4.54 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 57.57 V/m; Power Drift = 0.10 dB Peak SAR (extrapolated) = 6.89 W/kg SAR(1 g) = 3.78 W/kg; SAR(10 g) = 2.01 W/kg Smallest distance from peaks to all points 3 dB below = 11 mm Ratio of SAR at M2 to SAR at M1 = 55.7% Maximum value of SAR (measured) = 5.06 W/kg

0 dB = 5.06 W/kg = 7.04 dBW/kg

Plot No. 4

Test Laboratory: UL Verification Services Inc. SAR Lab D

Date/Time: 7/14/2022 12:12:03 PM

20220714_SystemPerformanceCheck-D2300V2 SN 1058

Frequency: 2300 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 2300 MHz;  = 1.713 S/m; r = 37.637;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1239; Calibrated: 3/21/2022 - Probe: EX3DV4 - SN7587; ConvF(7.91, 7.91, 7.91) @ 2300 MHz; Calibrated: 4/27/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM (B); Type: QD000P40CD; Serial: 1632
Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 6.52 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 66.35 V/m; Power Drift = -0.14 dB Peak SAR (extrapolated) = 10.7 W/kg SAR(1 g) = 5.22 W/kg; SAR(10 g) = 2.49 W/kg Smallest distance from peaks to all points 3 dB below = 10 mm Ratio of SAR at M2 to SAR at M1 = 49.2% Maximum value of SAR (measured) = 7.36 W/kg

0 dB = 7.36 W/kg = 8.67 dBW/kg

Plot No. 5

Test Laboratory: UL Verification Services Inc. SAR Lab E

Date/Time: 6/30/2022 4:02:40 AM

20220630_SystemPerformanceCheck-D2450V2 SN 706

Frequency: 2450 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 2450 MHz;  = 1.75 S/m; r = 40.265;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1377; Calibrated: 9/20/2021 - Probe: EX3DV4 - SN3885; ConvF(7.39, 7.39, 7.39) @ 2450 MHz; Calibrated: 9/23/2021 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V5.0 (20deg probe tilt); Type: QD 000 P40 CD; Serial: xxxx
Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 6.40 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 69.15 V/m; Power Drift = -0.07 dB Peak SAR (extrapolated) = 12.1 W/kg SAR(1 g) = 5.78 W/kg; SAR(10 g) = 2.71 W/kg Smallest distance from peaks to all points 3 dB below = 10 mm Ratio of SAR at M2 to SAR at M1 = 48.6% Maximum value of SAR (measured) = 8.24 W/kg

0 dB = 8.24 W/kg = 9.16 dBW/kg

Plot No. 6

Test Laboratory: UL Verification Services Inc. SAR Lab F

Date/Time: 7/7/2022 4:13:39 PM

20220707_SystemPerformanceCheck-D5GHzV2 SN 1168

Frequency: 5250 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 5250 MHz;  = 4.729 S/m; r = 35.461;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1257; Calibrated: 9/15/2021 - Probe: EX3DV4 - SN3749; ConvF(4.66, 4.66, 4.66) @ 5250 MHz; Calibrated: 1/18/2022 - Sensor-Surface: 1.4mm (Mechanical Surface Detection) - Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: 1740
Head/5.25 GHz, Pin=100mW/Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 18.8 W/kg
Head/5.25 GHz, Pin=100mW/Zoom Scan (8x8x8)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=1.4mm Reference Value = 56.02 V/m; Power Drift = 0.19 dB Peak SAR (extrapolated) = 31.6 W/kg SAR(1 g) = 8.04 W/kg; SAR(10 g) = 2.31 W/kg Smallest distance from peaks to all points 3 dB below = 7.2 mm Ratio of SAR at M2 to SAR at M1 = 66.3% Maximum value of SAR (measured) = 18.8 W/kg

0 dB = 18.8 W/kg = 12.74 dBW/kg

Plot No. 7

Test Laboratory: UL Verification Services Inc. SAR Lab G

Date/Time: 6/30/2022 3:25:42 AM

20220630_SystemPerformanceCheck-D5GHzV2 SN 1003

Frequency: 5600 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 5600 MHz;  = 4.827 S/m; r = 36.649;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1472; Calibrated: 1/7/2022 - Probe: EX3DV4 - SN7585; ConvF(4.68, 4.68, 4.68) @ 5600 MHz; Calibrated: 4/27/2022 - Sensor-Surface: 1.4mm (Mechanical Surface Detection) - Phantom: Twin-SAM V5.0 (20deg probe tilt); Type: QD 000 P40 CD; Serial: xxxx
Body/5.6 GHz, Pin=100mW/Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 19.3 W/kg
Body/5.6 GHz, Pin=100mW/Zoom Scan (8x8x8)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=1.4mm Reference Value = 53.99 V/m; Power Drift = -0.05 dB Peak SAR (extrapolated) = 35.3 W/kg SAR(1 g) = 7.84 W/kg; SAR(10 g) = 2.3 W/kg Smallest distance from peaks to all points 3 dB below = 7.6 mm Ratio of SAR at M2 to SAR at M1 = 61.1% Maximum value of SAR (measured) = 18.7 W/kg

0 dB = 18.7 W/kg = 12.72 dBW/kg

Plot No. 8

Test Laboratory: UL Verification Services Inc. SAR Lab G

Date/Time: 7/17/2022 9:15:57 AM

20220717_SystemPerformanceCheck-D5GHzV2 SN 1168

Frequency: 5600 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 5600 MHz;  = 4.951 S/m; r = 35.115;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1472; Calibrated: 1/7/2022 - Probe: EX3DV4 - SN7585; ConvF(4.68, 4.68, 4.68) @ 5600 MHz; Calibrated: 4/27/2022 - Sensor-Surface: 1.4mm (Mechanical Surface Detection) - Phantom: Twin-SAM V5.0 (20deg probe tilt); Type: QD 000 P40 CD; Serial: xxxx
Head/5.6 GHz, Pin=100mW/Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 18.9 W/kg
Head/5.6 GHz, Pin=100mW/Zoom Scan (8x8x8)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=1.4mm Reference Value = 54.48 V/m; Power Drift = -0.17 dB Peak SAR (extrapolated) = 33.7 W/kg SAR(1 g) = 8.21 W/kg; SAR(10 g) = 2.4 W/kg Smallest distance from peaks to all points 3 dB below = 7.4 mm Ratio of SAR at M2 to SAR at M1 = 64% Maximum value of SAR (measured) = 19.0 W/kg

0 dB = 19.0 W/kg = 12.79 dBW/kg

Plot No. 9

Test Laboratory: UL Verification Services Inc. SAR Lab H

Date/Time: 7/3/2022 7:32:30 AM

20220703_SystemPerformanceCheck-D2300V2 SN 1058

Frequency: 2300 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 2300 MHz;  = 1.613 S/m; r = 38.426;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1544; Calibrated: 1/7/2022 - Probe: EX3DV4 - SN7448; ConvF(7.86, 7.86, 7.86) @ 2300 MHz; Calibrated: 2/25/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: 1831
Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 6.37 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 59.42 V/m; Power Drift = 0.02 dB Peak SAR (extrapolated) = 9.44 W/kg SAR(1 g) = 4.89 W/kg; SAR(10 g) = 2.42 W/kg Smallest distance from peaks to all points 3 dB below = 10 mm Ratio of SAR at M2 to SAR at M1 = 52.8% Maximum value of SAR (measured) = 6.80 W/kg

0 dB = 6.80 W/kg = 8.33 dBW/kg

Plot No. 10

Test Laboratory: UL Verification Services Inc. SAR Lab H

Date/Time: 7/17/2022 7:58:18 AM

20220717_SystemPerformanceCheck-D5GHzV2 SN 1168

Frequency: 5750 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 5750 MHz;  = 5.124 S/m; r = 35.38;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1544; Calibrated: 1/7/2022 - Probe: EX3DV4 - SN7448; ConvF(4.6, 4.6, 4.6) @ 5750 MHz; Calibrated: 2/25/2022 - Sensor-Surface: 1.4mm (Mechanical Surface Detection) - Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: 1831
Head/5.75 GHz, Pin=100mW/Area Scan (7x7x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 16.5 W/kg
Head/5.75 GHz, Pin=100mW/Zoom Scan (8x8x8)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=1.4mm Reference Value = 49.64 V/m; Power Drift = 0.09 dB Peak SAR (extrapolated) = 37.5 W/kg SAR(1 g) = 8.33 W/kg; SAR(10 g) = 2.41 W/kg Smallest distance from peaks to all points 3 dB below = 7.5 mm Ratio of SAR at M2 to SAR at M1 = 61.9% Maximum value of SAR (measured) = 20.1 W/kg

0 dB = 20.1 W/kg = 13.03 dBW/kg

Plot No. 11

Test Laboratory: UL Verification Services Inc. SAR Lab H

Date/Time: 7/18/2022 7:29:20 PM

20220718_SystemPerformanceCheck-D2450V2 SN 706

Frequency: 2450 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 2450 MHz;  = 1.74 S/m; r = 37.872;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1544; Calibrated: 1/7/2022 - Probe: EX3DV4 - SN7448; ConvF(7.63, 7.63, 7.63) @ 2450 MHz; Calibrated: 2/25/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: 1831
Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 6.33 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 64.71 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 10.4 W/kg SAR(1 g) = 5.34 W/kg; SAR(10 g) = 2.61 W/kg Smallest distance from peaks to all points 3 dB below = 10 mm Ratio of SAR at M2 to SAR at M1 = 52.2% Maximum value of SAR (measured) = 7.41 W/kg

0 dB = 7.41 W/kg = 8.70 dBW/kg

Plot No. 12

Test Laboratory: UL Verification Services Inc. SAR Lab 1

Date/Time: 7/17/2022 8:55:19 AM

20220717_SystemPerformanceCheck-D2600V2 SN 1006

Frequency: 2600 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 2600 MHz;  = 1.9 S/m; r = 37.9;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1359; Calibrated: 1/7/2022 - Probe: EX3DV4 - SN3991; ConvF(7.9, 7.9, 7.9) @ 2600 MHz; Calibrated: 8/20/2021 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V8.0 (20deg probe tilt); Type: QD 000 P41 AA; Serial: 1956
Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 7.18 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 68.02 V/m; Power Drift = -0.10 dB Peak SAR (extrapolated) = 13.0 W/kg SAR(1 g) = 5.96 W/kg; SAR(10 g) = 2.66 W/kg Smallest distance from peaks to all points 3 dB below = 9 mm Ratio of SAR at M2 to SAR at M1 = 46.7% Maximum value of SAR (measured) = 8.61 W/kg

0 dB = 8.61 W/kg = 9.35 dBW/kg

Plot No. 13

Test Laboratory: UL Verification Services Inc. SAR Lab 3

Date/Time: 7/10/2022 8:24:42 AM

20220710_SystemPerformanceCheck-D3500V2 SN 1060

Frequency: 3500 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 3500 MHz;  = 2.795 S/m; r = 39.74;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1540; Calibrated: 1/11/2022 - Probe: EX3DV4 - SN7356; ConvF(7.2, 7.2, 7.2) @ 3500 MHz; Calibrated: 3/24/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V5.0 (20deg probe tilt); Type: SAM;
Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 7.42 W/kg
Head/Pin=100 mW/Zoom Scan (8x8x8)/Cube 0: Measurement grid: dx=4.3mm, dy=4.3mm, dz=3mm
Reference Value = 58.83 V/m; Power Drift = 0.04 dB Peak SAR (extrapolated) = 15.7 W/kg SAR(1 g) = 6.12 W/kg; SAR(10 g) = 2.38 W/kg Smallest distance from peaks to all points 3 dB below = 9 mm Ratio of SAR at M2 to SAR at M1 = 56.8% Maximum value of SAR (measured) = 9.14 W/kg

0 dB = 9.14 W/kg = 9.61 dBW/kg

Plot No. 14

Test Laboratory: UL Verification Services Inc. SAR Lab 3

Date/Time: 7/10/2022 9:00:42 AM

20220710_SystemPerformanceCheck-D3700V2 SN 1039

Frequency: 3700 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 3700 MHz;  = 2.981 S/m; r = 39.396;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1540; Calibrated: 1/11/2022 - Probe: EX3DV4 - SN7356; ConvF(7.15, 7.15, 7.15) @ 3700 MHz; Calibrated: 3/24/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V5.0 (20deg probe tilt); Type: SAM;
Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 7.67 W/kg
Head/Pin=100 mW/Zoom Scan (8x8x8)/Cube 0: Measurement grid: dx=4.3mm, dy=4.3mm, dz=3mm
Reference Value = 63.81 V/m; Power Drift = -0.02 dB Peak SAR (extrapolated) = 19.6 W/kg SAR(1 g) = 7.39 W/kg; SAR(10 g) = 2.77 W/kg Smallest distance from peaks to all points 3 dB below = 8.6 mm Ratio of SAR at M2 to SAR at M1 = 54.6% Maximum value of SAR (measured) = 11.0 W/kg

0 dB = 11.0 W/kg = 10.41 dBW/kg

Plot No. 15

Test Laboratory: UL Verification Services Inc. SAR Lab 3

Date/Time: 7/14/2022 9:09:03 AM

20220714_SystemPerformanceCheck-D3900V2 SN 1052

Frequency: 3900 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 3900 MHz;  = 3.179 S/m; r = 39.053;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1540; Calibrated: 1/11/2022 - Probe: EX3DV4 - SN7356; ConvF(7.1, 7.1, 7.1) @ 3900 MHz; Calibrated: 3/24/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V5.0 (20deg probe tilt); Type: SAM;
Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 7.37 W/kg
Head/Pin=100 mW/Zoom Scan (8x8x8)/Cube 0: Measurement grid: dx=4.3mm, dy=4.3mm, dz=3mm
Reference Value = 61.17 V/m; Power Drift = -0.01 dB Peak SAR (extrapolated) = 17.6 W/kg SAR(1 g) = 6.74 W/kg; SAR(10 g) = 2.41 W/kg Smallest distance from peaks to all points 3 dB below = 8.6 mm Ratio of SAR at M2 to SAR at M1 = 55% Maximum value of SAR (measured) = 10.4 W/kg

0 dB = 10.4 W/kg = 10.17 dBW/kg

Plot No. 16

Test Laboratory: UL Verification Services Inc. SAR Lab 3

Date/Time: 7/18/2022 12:32:19 PM

20220718_SystemPerformanceCheck-D2300V2 SN 1058

Frequency: 2300 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 2300 MHz;  = 1.708 S/m; r = 38.215;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1540; Calibrated: 1/11/2022 - Probe: EX3DV4 - SN7356; ConvF(8.48, 8.48, 8.48) @ 2300 MHz; Calibrated: 3/24/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V5.0 (20deg probe tilt); Type: SAM;
Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 5.57 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 62.48 V/m; Power Drift = 0.06 dB Peak SAR (extrapolated) = 9.57 W/kg SAR(1 g) = 4.79 W/kg; SAR(10 g) = 2.29 W/kg Smallest distance from peaks to all points 3 dB below = 9.1 mm Ratio of SAR at M2 to SAR at M1 = 51.3% Maximum value of SAR (measured) = 6.75 W/kg

0 dB = 6.75 W/kg = 8.29 dBW/kg

Plot No. 17

Test Laboratory: UL Verification Services Inc. SAR Lab 4

Date/Time: 7/3/2022 10:00:58 AM

20220703_SystemPerformanceCheck-D3700V2 SN 1039

Frequency: 3700 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 3700 MHz;  = 2.961 S/m; r = 39.308;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1433; Calibrated: 2/23/2022 - Probe: EX3DV4 - SN3929; ConvF(6.4, 6.4, 6.4) @ 3700 MHz; Calibrated: 3/23/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V8.0 (20deg probe tilt); Type: QD 000 P41 AA; Serial: 1956
Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 7.79 W/kg
Head/Pin=100 mW/Zoom Scan (8x8x8)/Cube 0: Measurement grid: dx=4.3mm, dy=4.3mm, dz=3mm
Reference Value = 59.94 V/m; Power Drift = -0.01 dB Peak SAR (extrapolated) = 17.9 W/kg SAR(1 g) = 6.59 W/kg; SAR(10 g) = 2.45 W/kg Smallest distance from peaks to all points 3 dB below = 8.6 mm Ratio of SAR at M2 to SAR at M1 = 54.3% Maximum value of SAR (measured) = 9.82 W/kg

0 dB = 9.82 W/kg = 9.92 dBW/kg

Plot No. 18

Test Laboratory: UL Verification Services Inc. SAR Lab 4

Date/Time: 7/3/2022 11:18:11 AM

20220703_SystemPerformanceCheck-D3900V2 SN 1052

Frequency: 3900 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 3900 MHz;  = 3.164 S/m; r = 38.997;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1433; Calibrated: 2/23/2022 - Probe: EX3DV4 - SN3929; ConvF(6.34, 6.34, 6.34) @ 3900 MHz; Calibrated: 3/23/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V8.0 (20deg probe tilt); Type: QD 000 P41 AA; Serial: 1956
Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 7.14 W/kg
Head/Pin=100 mW/Zoom Scan (8x8x8)/Cube 0: Measurement grid: dx=4.3mm, dy=4.3mm, dz=3mm
Reference Value = 57.65 V/m; Power Drift = 0.09 dB Peak SAR (extrapolated) = 17.3 W/kg SAR(1 g) = 6.45 W/kg; SAR(10 g) = 2.3 W/kg Smallest distance from peaks to all points 3 dB below = 8.5 mm Ratio of SAR at M2 to SAR at M1 = 54% Maximum value of SAR (measured) = 9.73 W/kg

0 dB = 9.73 W/kg = 9.88 dBW/kg

Plot No. 19

Test Laboratory: UL Verification Services Inc. SAR Lab 4

Date/Time: 7/10/2022 6:52:27 AM

20220710_SystemPerformanceCheck-D3500V2 SN 1011

Frequency: 3500 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 3500 MHz;  = 2.777 S/m; r = 39.509;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1433; Calibrated: 2/23/2022 - Probe: EX3DV4 - SN3929; ConvF(6.5, 6.5, 6.5) @ 3500 MHz; Calibrated: 3/23/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V8.0 (20deg probe tilt); Type: QD 000 P41 Ax; Serial: xxxx
Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 6.55 W/kg
Head/Pin=100 mW/Zoom Scan (8x8x8)/Cube 0: Measurement grid: dx=4.3mm, dy=4.3mm, dz=3mm
Reference Value = 59.16 V/m; Power Drift = 0.08 dB Peak SAR (extrapolated) = 16.0 W/kg SAR(1 g) = 6.29 W/kg; SAR(10 g) = 2.46 W/kg Smallest distance from peaks to all points 3 dB below = 9 mm Ratio of SAR at M2 to SAR at M1 = 57.2% Maximum value of SAR (measured) = 9.39 W/kg

0 dB = 9.39 W/kg = 9.73 dBW/kg

Plot No. 20

Test Laboratory: UL Verification Services Inc. SAR Lab 4

Date/Time: 7/13/2022 1:14:50 AM

20220713_SystemPerformanceCheck-D2600V2 SN 1006

Frequency: 2600 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 2600 MHz;  = 1.897 S/m; r = 38.229;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1433; Calibrated: 2/23/2022 - Probe: EX3DV4 - SN3929; ConvF(6.98, 6.98, 6.98) @ 2600 MHz; Calibrated: 3/23/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V8.0 (20deg probe tilt); Type: QD 000 P41 Ax; Serial: xxxx
Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 6.08 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 64.18 V/m; Power Drift = 0.20 dB Peak SAR (extrapolated) = 12.0 W/kg SAR(1 g) = 5.62 W/kg; SAR(10 g) = 2.54 W/kg Smallest distance from peaks to all points 3 dB below = 9.5 mm Ratio of SAR at M2 to SAR at M1 = 47.4% Maximum value of SAR (measured) = 8.11 W/kg

0 dB = 8.11 W/kg = 9.09 dBW/kg

Plot No. 21

Test Laboratory: UL Verification Services Inc. SAR Lab 6

Date/Time: 7/11/2022 7:02:07 AM

20220711_SystemPerformanceCheck-D2600V2 SN 1006

Frequency: 2600 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 2600 MHz;  = 2.02 S/m; r = 39.617;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4ip Sn1621; Calibrated: 4/21/2022 - Probe: EX3DV4 - SN3990; ConvF(7.53, 7.53, 7.53) @ 2600 MHz; Calibrated: 2/25/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V8.0 (30deg probe tilt); Type: QD 000 P41 Ax; Serial: xxxx
Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 7.81 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 60.92 V/m; Power Drift = 0.17 dB Peak SAR (extrapolated) = 13.1 W/kg SAR(1 g) = 5.98 W/kg; SAR(10 g) = 2.66 W/kg Smallest distance from peaks to all points 3 dB below = 9 mm Ratio of SAR at M2 to SAR at M1 = 46.3% Maximum value of SAR (measured) = 8.66 W/kg

0 dB = 8.66 W/kg = 9.38 dBW/kg

Plot No. 22

Test Laboratory: UL Verification Services Inc. SAR Lab 6

Date/Time: 7/17/2022 8:24:34 AM

20220717_SystemPerformanceCheck-D3500V2 SN 1060

Frequency: 3500 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 3500 MHz;  = 2.779 S/m; r = 37.25;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4ip Sn1621; Calibrated: 4/21/2022 - Probe: EX3DV4 - SN3990; ConvF(6.92, 6.92, 6.92) @ 3500 MHz; Calibrated: 2/25/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V8.0 (30deg probe tilt); Type: QD 000 P41 Ax; Serial: xxxx
Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 6.54 W/kg
Head/Pin=100 mW/Zoom Scan (8x8x8)/Cube 0: Measurement grid: dx=4.3mm, dy=4.3mm, dz=3mm
Reference Value = 59.22 V/m; Power Drift = -0.04 dB Peak SAR (extrapolated) = 15.4 W/kg SAR(1 g) = 6.19 W/kg; SAR(10 g) = 2.37 W/kg Smallest distance from peaks to all points 3 dB below = 8.5 mm Ratio of SAR at M2 to SAR at M1 = 57.5% Maximum value of SAR (measured) = 9.17 W/kg

0 dB = 9.17 W/kg = 9.62 dBW/kg

Plot No. 23

Test Laboratory: UL Verification Services Inc. SAR Lab 6

Date/Time: 7/17/2022 8:48:17 AM

20220717_SystemPerformanceCheck-D3700V2 SN 1039

Frequency: 3700 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 3700 MHz;  = 2.993 S/m; r = 37.377;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4ip Sn1621; Calibrated: 4/21/2022 - Probe: EX3DV4 - SN3990; ConvF(6.9, 6.9, 6.9) @ 3700 MHz; Calibrated: 2/25/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V8.0 (30deg probe tilt); Type: QD 000 P41 Ax; Serial: xxxx
Head/Pin=100 mW 2/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 6.09 W/kg
Head/Pin=100 mW 2/Zoom Scan (8x8x8)/Cube 0: Measurement grid: dx=4.3mm, dy=4.3mm, dz=3mm
Reference Value = 59.50 V/m; Power Drift = -0.09 dB Peak SAR (extrapolated) = 16.6 W/kg SAR(1 g) = 6.32 W/kg; SAR(10 g) = 2.33 W/kg Smallest distance from peaks to all points 3 dB below = 8.5 mm Ratio of SAR at M2 to SAR at M1 = 55.6% Maximum value of SAR (measured) = 9.51 W/kg

0 dB = 9.51 W/kg = 9.78 dBW/kg

Plot No. 24

Test Laboratory: UL Verification Services Inc. SAR Lab 6

Date/Time: 7/17/2022 9:27:28 AM

20220717_SystemPerformanceCheck-D3900V2 SN 1052

Frequency: 3900 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 3900 MHz;  = 3.191 S/m; r = 37.041;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4ip Sn1621; Calibrated: 4/21/2022 - Probe: EX3DV4 - SN3990; ConvF(6.76, 6.76, 6.76) @ 3900 MHz; Calibrated: 2/25/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V8.0 (30deg probe tilt); Type: QD 000 P41 Ax; Serial: xxxx
Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 6.92 W/kg
Head/Pin=100 mW/Zoom Scan (8x8x8)/Cube 0: Measurement grid: dx=4.3mm, dy=4.3mm, dz=3mm
Reference Value = 57.93 V/m; Power Drift = 0.17 dB Peak SAR (extrapolated) = 17.1 W/kg SAR(1 g) = 6.44 W/kg; SAR(10 g) = 2.27 W/kg Smallest distance from peaks to all points 3 dB below = 8.5 mm Ratio of SAR at M2 to SAR at M1 = 54.5% Maximum value of SAR (measured) = 9.99 W/kg

0 dB = 9.99 W/kg = 10.00 dBW/kg

Plot No. 25

Test Laboratory: UL Verification Services Inc. SAR Lab 8

Date/Time: 7/14/2022 7:46:16 AM

20220714_SystemPerformanceCheck-D2450V2 SN 748

Frequency: 2450 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 2450 MHz;  = 1.875 S/m; r = 37.348;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1352; Calibrated: 11/9/2021 - Probe: EX3DV4 - SN3773; ConvF(7.17, 7.17, 7.17) @ 2450 MHz; Calibrated: 2/28/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: 1740
Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 7.33 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 62.39 V/m; Power Drift = 0.13 dB Peak SAR (extrapolated) = 12.1 W/kg SAR(1 g) = 5.66 W/kg; SAR(10 g) = 2.65 W/kg Smallest distance from peaks to all points 3 dB below = 10 mm Ratio of SAR at M2 to SAR at M1 = 47.7% Maximum value of SAR (measured) = 8.08 W/kg

0 dB = 7.33 W/kg = 8.65 dBW/kg

Plot No. 26

Test Laboratory: UL Verification Services Inc. SAR Lab 8

Date/Time: 7/17/2022 10:25:02 AM

20220717_SystemPerformanceCheck-D2600V2 SN 1006

Frequency: 2600 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 2600 MHz;  = 1.955 S/m; r = 37.429;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1352; Calibrated: 11/9/2021 - Probe: EX3DV4 - SN3773; ConvF(7.08, 7.08, 7.08) @ 2600 MHz; Calibrated: 2/28/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: 1740
Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 8.27 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 56.45 V/m; Power Drift = 0.07 dB Peak SAR (extrapolated) = 12.5 W/kg SAR(1 g) = 5.86 W/kg; SAR(10 g) = 2.69 W/kg Smallest distance from peaks to all points 3 dB below = 9.8 mm Ratio of SAR at M2 to SAR at M1 = 47.4% Maximum value of SAR (measured) = 8.39 W/kg

0 dB = 8.39 W/kg = 9.24 dBW/kg

Plot No. 27

Test Laboratory: UL Verification Services Inc. SAR Lab 10

Date/Time: 7/5/2022 9:03:13 AM

20220705_SystemPerformanceCheck-D750V3 SN 1019

Frequency: 750 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 750 MHz;  = 0.876 S/m; r = 40.923;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1547; Calibrated: 4/21/2022 - Probe: EX3DV4 - SN3989; ConvF(10.59, 10.59, 10.59) @ 750 MHz; Calibrated: 1/19/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM with CRP v5.0; Type: QD000P40CD; Serial: TP:xxxx
Head/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.992 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 33.20 V/m; Power Drift = 0.05 dB Peak SAR (extrapolated) = 1.35 W/kg SAR(1 g) = 0.812 W/kg; SAR(10 g) = 0.525 W/kg Maximum value of SAR (measured) = 1.02 W/kg

0 dB = 1.02 W/kg = 0.09 dBW/kg

Plot No. 28

Test Laboratory: UL Verification Services Inc. SAR Lab 10

Date/Time: 7/12/2022 1:45:20 AM

20220712_SystemPerformanceCheck-D2300V2 SN 1058

Frequency: 2300 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 2300 MHz;  = 1.615 S/m; r = 37.778;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1547; Calibrated: 4/21/2022 - Probe: EX3DV4 - SN3989; ConvF(8.37, 8.37, 8.37) @ 2300 MHz; Calibrated: 1/19/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection (Locations From Previous Scan Used)), Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM with CRP v5.0; Type: QD000P40CD; Serial: TP:xxxx
Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 5.58 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 65.14 V/m; Power Drift = 0.07 dB Peak SAR (extrapolated) = 9.88 W/kg SAR(1 g) = 4.91 W/kg; SAR(10 g) = 2.37 W/kg Maximum value of SAR (measured) = 6.84 W/kg

0 dB = 6.84 W/kg = 8.35 dBW/kg

Plot No. 29

Test Laboratory: UL Verification Services Inc. SAR Lab 10

Date/Time: 7/19/2022 12:05:20 AM

20220719_SystemPerformanceCheck-D3700V2 SN 1039

Frequency: 3700 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 3700 MHz;  = 3.001 S/m; r = 39.41;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1547; Calibrated: 4/21/2022 - Probe: EX3DV4 - SN3989; ConvF(7.05, 7.05, 7.05) @ 3700 MHz; Calibrated: 1/19/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM with CRP v5.0; Type: QD000P40CD; Serial: TP:xxxx
Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 8.63 W/kg
Head/Pin=100 mW/Zoom Scan (8x8x8)/Cube 0: Measurement grid: dx=4.3mm, dy=4.3mm, dz=3mm
Reference Value = 46.02 V/m; Power Drift = -0.14 dB Peak SAR (extrapolated) = 17.1 W/kg SAR(1 g) = 6.61 W/kg; SAR(10 g) = 2.52 W/kg Maximum value of SAR (measured) = 9.86 W/kg

0 dB = 9.86 W/kg = 9.94 dBW/kg

Plot No. 30

Test Laboratory: UL Verification Services Inc. SAR Lab 11

Date/Time: 7/11/2022 11:09:40 PM

20220711_SystemPerformanceCheck-D1900V2 SN 5d163

Frequency: 1900 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 1900 MHz;  = 1.444 S/m; r = 39.094;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1548; Calibrated: 2/23/2022 - Probe: EX3DV4 - SN7482; ConvF(8.12, 8.12, 8.12); Calibrated: 4/26/2022; - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM with CRP; Type: SAM; Serial: 2048
Head/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 5.63 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 63.33 V/m; Power Drift = 0.06 dB Peak SAR (extrapolated) = 8.21 W/kg SAR(1 g) = 4.34 W/kg; SAR(10 g) = 2.25 W/kg Maximum value of SAR (measured) = 5.93 W/kg

0 dB = 5.93 W/kg = 7.73 dBW/kg

Plot No. 31

Test Laboratory: UL Verification Services Inc. SAR Lab 11

Date/Time: 7/17/2022 6:42:58 PM

20220717_SystemPerformanceCheck-D900V2 SN 1d143

Frequency: 900 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 900 MHz;  = 0.932 S/m; r = 40.816;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1548; Calibrated: 2/23/2022 - Probe: EX3DV4 - SN7482; ConvF(9.01, 9.01, 9.01); Calibrated: 4/26/2022; - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: SAM with CRP; Type: SAM; Serial: 1751
Head/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 1.35 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 39.58 V/m; Power Drift = -0.17 dB Peak SAR (extrapolated) = 1.71 W/kg SAR(1 g) = 1.14 W/kg; SAR(10 g) = 0.741 W/kg Maximum value of SAR (measured) = 1.39 W/kg

0 dB = 1.39 W/kg = 1.43 dBW/kg

Plot No. 32

Test Laboratory: UL Verification Services Inc. SAR Lab 12

Date/Time: 7/1/2022 7:47:48 PM

20220701_SystemPerformanceCheck-D750V3 SN 1019

Frequency: 750 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 750 MHz;  = 0.902 S/m; r = 40.938;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1380; Calibrated: 8/11/2021 - Probe: EX3DV4 - SN3686; ConvF(9.75, 9.75, 9.75) @ 750 MHz; Calibrated: 1/18/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: xxxx
Head/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 1.01 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 32.14 V/m; Power Drift = 0.15 dB Peak SAR (extrapolated) = 1.53 W/kg SAR(1 g) = 0.916 W/kg; SAR(10 g) = 0.587 W/kg Smallest distance from peaks to all points 3 dB below: Larger than measurement grid (> 15 mm) Ratio of SAR at M2 to SAR at M1 = 62.3% Maximum value of SAR (measured) = 1.14 W/kg

0 dB = 1.14 W/kg = 0.57 dBW/kg

Plot No. 33

Test Laboratory: UL Verification Services Inc. SAR Lab 12

Date/Time: 7/11/2022 8:56:58 PM

20220711_SystemPerformanceCheck-D1640V2 SN 324

Frequency: 1640 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 1640 MHz;  = 1.287 S/m; r = 38.763;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1380; Calibrated: 8/11/2021 - Probe: EX3DV4 - SN3686; ConvF(7.68, 7.68, 7.68) @ 1640 MHz; Calibrated: 1/18/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: xxxx
Head/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 3.12 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 57.25 V/m; Power Drift = 0.18 dB Peak SAR (extrapolated) = 5.48 W/kg SAR(1 g) = 3.07 W/kg; SAR(10 g) = 1.69 W/kg Smallest distance from peaks to all points 3 dB below = 12 mm Ratio of SAR at M2 to SAR at M1 = 57% Maximum value of SAR (measured) = 4.06 W/kg

0 dB = 4.06 W/kg = 6.09 dBW/kg

Plot No. 34

Test Laboratory: UL Verification Services Inc. SAR Lab 12

Date/Time: 7/13/2022 12:15:25 PM

20220713_SystemPerformanceCheck-D1750V2 SN 1077

Frequency: 1750 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 1750 MHz;  = 1.318 S/m; r = 42.077;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1380; Calibrated: 8/11/2021 - Probe: EX3DV4 - SN3686; ConvF(7.67, 7.67, 7.67) @ 1750 MHz; Calibrated: 1/18/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V5.0 (30deg probe tilt); Type: QD 000 P40 CD; Serial: xxxx
Head/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 3.47 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 51.62 V/m; Power Drift = 0.10 dB Peak SAR (extrapolated) = 6.22 W/kg SAR(1 g) = 3.36 W/kg; SAR(10 g) = 1.79 W/kg Smallest distance from peaks to all points 3 dB below = 11 mm Ratio of SAR at M2 to SAR at M1 = 55.3% Maximum value of SAR (measured) = 4.50 W/kg

0 dB = 4.50 W/kg = 6.53 dBW/kg

Plot No. 35

Test Laboratory: UL Verification Services Inc. SAR Lab 13

Date/Time: 7/1/2022 8:49:51 PM

20220701_SystemPerformanceCheck-D835V2 SN 4d142

Frequency: 835 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 835 MHz;  = 0.914 S/m; r = 39.676;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1263; Calibrated: 10/12/2021 - Probe: EX3DV4 - SN7589; ConvF(10.09, 10.09, 10.09) @ 835 MHz; Calibrated: 4/28/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V8.0 (20deg probe tilt); Type: QD 000 P41 Ax; Serial: xxxx
Head/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 1.11 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 35.31 V/m; Power Drift = 0.14 dB Peak SAR (extrapolated) = 1.50 W/kg SAR(1 g) = 1.01 W/kg; SAR(10 g) = 0.665 W/kg Smallest distance from peaks to all points 3 dB below: Larger than measurement grid Ratio of SAR at M2 to SAR at M1 = 67.4% Maximum value of SAR (measured) = 1.23 W/kg

0 dB = 1.23 W/kg = 0.90 dBW/kg

Plot No. 36

Test Laboratory: UL Verification Services Inc. SAR Lab 13

Date/Time: 7/15/2022 1:42:31 PM

20220715_SystemPerformanceCheck-D1900V2 SN 5d163

Frequency: 1900 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 1900 MHz;  = 1.423 S/m; r = 38.237;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1263; Calibrated: 10/12/2021 - Probe: EX3DV4 - SN7589; ConvF(8.35, 8.35, 8.35) @ 1900 MHz; Calibrated: 4/28/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V8.0 (20deg probe tilt); Type: QD 000 P41 Ax; Serial: xxxx
Head/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 4.19 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 59.97 V/m; Power Drift = 0.19 dB Peak SAR (extrapolated) = 7.83 W/kg SAR(1 g) = 4.23 W/kg; SAR(10 g) = 2.24 W/kg Smallest distance from peaks to all points 3 dB below = 10.8 mm Ratio of SAR at M2 to SAR at M1 = 55.2% Maximum value of SAR (measured) = 5.69 W/kg

0 dB = 5.69 W/kg = 7.55 dBW/kg

Plot No. 37

Test Laboratory: UL Verification Services Inc. SAR Lab 13

Date/Time: 7/17/2022 7:59:19 PM

20220717_SystemPerformanceCheck-D900V2 SN 1d143

Frequency: 900 MHz; Duty Cycle: 1:1; Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C Medium parameters used: f = 900 MHz;  = 0.909 S/m; r = 42.731;  = 1000 kg/m3 Dasy Configuration: - Area Scan Setting: Find Secondary Maximum within 2.0 dB and with a peak SAR value greater than 0.0012 W/kg - Electronics: DAE4 Sn1263; Calibrated: 10/12/2021 - Probe: EX3DV4 - SN7589; ConvF(10.09, 10.09, 10.09) @ 900 MHz; Calibrated: 4/28/2022 - Sensor-Surface: 2.5mm (Mechanical Surface Detection) - Phantom: Twin-SAM V8.0 (20deg probe tilt); Type: QD 000 P41 Ax; Serial: xxxx
Head/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 1.19 W/kg
Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 36.78 V/m; Power Drift = 0.14 dB Peak SAR (extrapolated) = 1.72 W/kg SAR(1 g) = 1.09 W/kg; SAR(10 g) = 0.699 W/kg Smallest distance from peaks to all points 3 dB below: Larger than measurement grid Ratio of SAR at M2 to SAR at M1 = 64.2% Maximum value of SAR (measured) = 1.35 W/kg

0 dB = 1.35 W/kg = 1.30 dBW/kg

Plot No. 38



Related FCC IDs: