Document DEVICE REPORTGetApplicationAttachment.html?id=6130461Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 Report No.:DDT-R22072825-2E01 Issued Date: Aug. 31, 2022 FCC AND ISED CERTIFICATION TEST REPORT FOR Applicant Address Equipment under Test : Harman International Industries, Inc. : 8500 Balboa Boulevard, Northridge, CA 91329, UNITED STATES : Bluetooth Headset Model No. : TOUR ONE M2 Trade Mark : JBL FCC ID : APITOURONEM2 IC : 6132A-TOURONEM2 Manufacturer Address : Harman International Industries, Inc. : 8500 Balboa Boulevard, Northridge, CA 91329, UNITED STATES Issued By: Dongguan Dongdian Testing Service Co., Ltd. Add.: No. 17, Zongbu Road 2, Songshan Lake Sci&Tech, Industry Park, Dongguan City, Guangdong Province, China, 523808 Tel.: +86-0769-38826678, E-mail: [email protected], http://www.dgddt.com Page 1 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 Table of Contents Test report declares.......................................................................................................4 1. Summary of Test Results............................................................................................... 6 2. General Test Information ............................................................................................... 7 2.1. Description of EUT ......................................................................................................... 7 2.2. Accessories of EUT........................................................................................................ 8 2.3. Assistant equipment used for test .................................................................................. 8 2.4. Block diagram of EUT configuration for test .................................................................. 8 2.5. Deviations of test standard............................................................................................. 8 2.6. Test environment conditions .......................................................................................... 9 2.7. Test laboratory ............................................................................................................... 9 2.8. Measurement uncertainty............................................................................................... 9 3. Equipment Used During Test ....................................................................................... 10 4. Maximum Peak Output Power ..................................................................................... 11 4.1. Block diagram of test setup.......................................................................................... 11 4.2. Limits ............................................................................................................................ 11 4.3. Test procedure ............................................................................................................. 11 4.4. Test result..................................................................................................................... 12 4.5. Original test data .......................................................................................................... 13 5. 20 dB Bandwidth and 99% Bandwidth......................................................................... 16 5.1. Block diagram of test setup.......................................................................................... 16 5.2. Limits ............................................................................................................................ 16 5.3. Test procedure ............................................................................................................. 16 5.4. Test result..................................................................................................................... 16 5.5. Original test data .......................................................................................................... 17 6. Carrier Frequency Separation...................................................................................... 23 6.1. Block diagram of test setup.......................................................................................... 23 6.2. Limits ............................................................................................................................ 23 6.3. Test procedure ............................................................................................................. 23 6.4. Test result..................................................................................................................... 23 6.5. Original test data .......................................................................................................... 24 7. Number of Hopping Channel ....................................................................................... 25 7.1. Block diagram of test setup.......................................................................................... 25 7.2. Limits ............................................................................................................................ 25 7.3. Test procedure ............................................................................................................. 25 7.4. Test result..................................................................................................................... 25 7.5. Original test data .......................................................................................................... 26 8. Dwell Time.................................................................................................................... 27 Page 2 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 8.1. 8.2. 8.3. 8.4. 8.5. 9. 9.1. 9.2. 9.3. 9.4. 9.5. 10. 10.1. 10.2. 10.3. 10.4. 11. 11.1. 11.2. 11.3. 11.4. 11.5. 12. 12.1. 12.2. 12.3. 12.4. 13. 13.1. 13.2. 13.3. 13.4. 14. 14.1. 14.2. Block diagram of test setup.......................................................................................... 27 Limits ............................................................................................................................ 27 Test procedure ............................................................................................................. 27 Test result..................................................................................................................... 27 Original test data .......................................................................................................... 28 Band Edge Compliance (Conducted Method) ............................................................. 34 Block diagram of test setup.......................................................................................... 34 Limit .............................................................................................................................. 34 Test procedure ............................................................................................................. 34 Test result..................................................................................................................... 34 Original test data .......................................................................................................... 35 Radiated Emission ....................................................................................................... 39 Block diagram of test setup.......................................................................................... 39 Limit .............................................................................................................................. 40 Test Procedure............................................................................................................. 42 Test result..................................................................................................................... 43 RF Conducted Spurious Emissions ............................................................................. 58 Block diagram of test setup.......................................................................................... 58 Limits ............................................................................................................................ 58 Test procedure ............................................................................................................. 58 Test result..................................................................................................................... 59 Original test data .......................................................................................................... 59 Band Edge Compliance (Radiated Method) ................................................................ 69 Block diagram of test setup.......................................................................................... 69 Limit .............................................................................................................................. 69 Test Procedure............................................................................................................. 69 Test result..................................................................................................................... 69 Power Line Conducted Emission ................................................................................. 82 Block diagram of test setup.......................................................................................... 82 Power line conducted emission limits .......................................................................... 82 Test procedure ............................................................................................................. 82 Test result..................................................................................................................... 83 Antenna Requirements ................................................................................................ 86 Limit .............................................................................................................................. 86 Result ........................................................................................................................... 86 Page 3 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 Test Report Declare Applicant Address Equipment under Test Model No. Trade Mark Manufacturer Address : Harman International Industries, Inc. : 8500 Balboa Boulevard, Northridge, CA 91329, UNITED STATES : Bluetooth Headset : TOUR ONE M2 : JBL : Harman International Industries, Inc. : 8500 Balboa Boulevard, Northridge, CA 91329, UNITED STATES Test Standard Used: FCC Rules and Regulations Part 15 Subpart C, RSS-247 Issue 2 February 2017. Test Procedure Used: ANSI C63.10:2013, RSS-Gen Issue 5, Apr. 2018, Amendment 2 (February 2021) We Declare: The equipment described above is tested by Dongguan Dongdian Testing Service Co., Ltd. and in the configuration tested the equipment complied with the standards specified above. The test results are contained in this test report and Dongguan Dongdian Testing Service Co., Ltd. is assumed of full responsibility for the accuracy and completeness of these tests. After test and evaluation, our opinion is that the equipment provided for test compliance with the requirement of the above FCC&ISED standards. Report No.: DDT-R22072825-2E01 Date of Receipt: Aug. 02, 2022 Date of Test: Aug. 02, 2022 ~ Aug. 31, 2022 Prepared By: Approv*'e,$d1 By: 7(67,1* 6 '21**8$1 '21 (59,&( &2 /7' ____________________ Bobo Chen/Engineer ______________________ Damon Hu/EMC Manager Note: This report applies to above tested sample only. This report shall not be reproduced in parts without written approval of Dongguan Dongdian Testing Service Co., Ltd. Page 4 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 Rev. Revisions --- Initial issue Revision History Issue Date Revised By Aug. 31, 2022 Page 5 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 1. Summary of Test Results Description of Test Item Maximum Peak Output Power 20 dB Bandwidth and 99% Bandwidth Carrier Frequency Separation Number of Hopping Channel Dwell Time Radiated Emission Band Edge Compliance Power Line Conducted Emissions Antenna Requirement Standard FCC Part 15: 15.247(b)(1) ANSI C63.10:2013 RSS-247 Issue 2 FCC Part 15: 15.215 ANSI C63.10:2013 RSS-247 Issue 2 FCC Part 15: 15.247(a)(1) ANSI C63.10:2013 RSS-247 Issue 2 FCC Part 15: 15.247(a)(1)(iii) ANSI C63.10:2013 RSS-247 Issue 2 FCC Part 15: 15.247(a)(1)(iii) ANSI C63.10:2013 RSS-247 Issue 2 FCC Part 15: 15.209 FCC Part 15: 15.247(d) ANSI C63.10:2013 RSS-247 Issue 2 RSS-Gen Issue 5 FCC Part 15: 15.247(d) ANSI C63.10:2013 RSS-247 Issue 2 RSS-Gen Issue 5 FCC Part 15: 15.207 ANSI C63.10:2013 RSS-Gen Issue 5 FCC Part 15: 15.203 RSS-Gen Issue 5 Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Page 6 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 2. General Test Information 2.1. Description of EUT EUT* Name : Bluetooth Headset Model Number : TOUR ONE M2 EUT Function Description Power Supply Radio Specification : Please reference user manual of this device : DC DC 5V from external USB cable 3.7V Polymer Li-ion built-in battery : Bluetooth V5.3 Operation Frequency : 2402MHz-2480MHz Modulation : GFSK, S/4-DQPSK, 8DPSK Data Rate : 1Mbps, 2Mbps, 3Mbps Antenna Gain : 1.37 dBi Sample Type : Series production Sample Number : S22072825-01 S22072825-02 for for conductive radiation Note: EUT is the ab. of equipment under test. Channel information Channel Frequency (MHz) 0 2402 1 2403 2 2404 3 2405 4 2406 5 2407 6 2408 7 2409 8 2410 9 2411 10 2412 11 2413 12 2414 13 2415 14 2416 15 2417 16 2418 17 2419 18 2420 19 2421 20 2422 21 2423 22 2424 23 2425 24 2426 25 2427 Channel 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 Frequency (MHz) 2429 2430 2431 2432 2433 2434 2435 2436 2437 2438 2439 2440 2441 2442 2443 2444 2445 2446 2447 2448 2449 2450 2451 2452 2453 2454 Channel 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 Frequency (MHz) 2456 2457 2458 2459 2460 2461 2462 2463 2464 2465 2466 2467 2468 2469 2470 2471 2472 2473 2474 2475 2476 2477 2478 2479 2480 Page 7 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 26 2428 53 2455 2.2. Accessories of EUT Description of Accessories USB Cable Manufacturer Harman Aux in cable Dongle Harman Harman Model number N/A N/A N/A Description Length: 1.0m unshielded Length: 1.22m unshielded N/A Remark N/A N/A N/A 2.3. Assistant equipment used for test Assistant equipment Adapter Manufacturer SUMSUNG Model number EMC Compliance SN Input: 100-240~, 50/60Hz, EP-TA200 0.5A; Output: 9V/1.67A or N/A 5V/2A 2.4. Block diagram of EUT configuration for test AC Mains AC Adapter EUT Test software: BQB.exe The test software was used to control EUT work in Continuous Tx mode, and select test channel, wireless mode as below table. The pathloss of external cable: 0.5dB (According to the manufacturer's claims) Tested mode, channel, information Mode Setting Tx Power Channel Frequency (MHz) GFSK hopping on Tx mode / CH0 to CH78 2402 to 2480 S/4-DQPSK hopping on Tx mode / CH0 to CH78 2402 to 2480 8DPSK hopping on Tx mode / CH0 to CH78 2402 to 2480 / CH0 2402 GFSK hopping off Tx mode / CH39 2441 / CH78 2480 / CH0 2402 S/4-DQPSK hopping off Tx mode / CH39 2441 / CH78 2480 / CH0 2402 8DPSK hopping off Tx mode / CH39 2441 / CH78 2480 2.5. Deviations of test standard No deviation. Page 8 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 2.6. Test environment conditions During the measurement the environmental conditions were within the listed ranges: Temperature range: Humidity range: Pressure range: 21-25 40-75% 86-106 kPa 2.7. Test laboratory Dongguan Dongdian Testing Service Co., Ltd. Add.: No. 17, Zongbu Road 2, Songshan Lake Sci&Tech, Industry Park, Dongguan City, Guangdong Province, China, 523808. Tel.: +86-0769-38826678, http://www.dgddt.com, Email: [email protected]. CNAS Accreditation No. L6451; A2LA Accreditation Number: 3870.01 FCC Designation Number: CN1182, Test Firm Registration Number: 540522 Innovation, Science and Economic Development Canada Site Registration Number: 10288A Conformity Assessment Body identifier: CN0048 VCCI facility registration number: C-20087, T-20088, R-20123, G-20118 2.8. Measurement uncertainty Test Item Uncertainty Bandwidth 1.1% Peak Output Power (Conducted) (Spectrum analyzer) 0.86 dB (10 MHz f < 3.6 GHz); 1.38 dB (3.6 GHz f < 8 GHz) Peak Output Power (Conducted) (Power Sensor) 0.74 dB Power Spectral Density 0.74 dB (10 MHz f < 3.6 GHz); 1.38 dB (3.6 GHz f < 8 GHz) Frequencies Stability 6.7 x 10-8 (Antenna couple method) 5.5 x 10-8 (Conducted method) 0.86 dB (10 MHz f < 3.6 GHz); Conducted spurious emissions 1.40 dB (3.6 GHz f < 8 GHz) 1.66 dB (8 GHz f < 22 GHz) Uncertainty for radio frequency (RBW < 20 kHz) 3×10-8 Temperature 0.4 Humidity 2 % Uncertainty for Radiation Emission test (30 MHz - 1 GHz) 4.70 dB (Antenna Polarize: V) 4.84 dB (Antenna Polarize: H) 4.10 dB (1 - 6 GHz) Uncertainty for Radiation Emission test (1 GHz - 40 GHz) 4.40 dB (6 GHz - 18 GHz) 3.54 dB (18 GHz - 26 GHz) 4.30 dB (26 GHz - 40 GHz) Uncertainty for Power line conduction emission test 3.72 dB (9 kHz-150 kHz) 3.32 dB (150 kHz - 30 MHz) Note: This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. Page 9 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 3. Equipment Used During Test Equipment Manufacturer Model No. Serial No. RF Connected Test (Tonscend RF Measurement System 4#) Signal &Spectrum analyzer Wideband Radio Communication tester MXG Vector Signal Generator Vector Signal Generator R&S R&S Agilent Agilent FSV3044 CMW500 N5182B E8267D 101173 120259 MY59100192 US49060192 RF Control Unit Tonsend JS0806-2 21I8060485 Temp&Humi Programmable ZHIXIANG ZXGDJS-150 L ZX170110-A Test Software JS Tonscend JS1120-3 Ver.2.6.88.0346 Radiation 3#chamber EMI Test Receiver R&S ESU 100472 Spectrum analyzer Agilent E4447A MY50180031 Active Loop antenna Schwarzbeck FMZB-1519 1519-038 Trilog Broadband Antenna Double Ridged Horn Antenna Broad Band Horn Antenna Pre-amplifier Pre-amplifier Schwarzbeck VULB 9163 01429 Schwarzbeck BBHA 9120 D 02468 Schwarzbeck BBHA 9170 790 COM-POWE R COM-POWE R PAM-118A PAM-840A 18040084 461369 Test software Audix E3 V 6.1.1.1 Power Line Conducted Emissions Test 1# Test Receiver R&S ESCI 100551 LISN 1 R&S ENV216 101109 LISN 2 R&S ESH2-Z5 100309 Pulse Limiter R&S ESH3-Z2 101242 CE Cable 1 HUBSER N/A W10.01 LISN 3 SCHWARZBE CK NSLK 8163 00017 Test software Audix E3 V 6.11111b Last Cal. Cal. Interval Apr. 13, 2022 1 Year May 18, 2022 1 Year May 18, 2022 1 Year Oct. 15, 2021 1 Year Oct. 18, 2021 1 Year May 16, 2022 1 Year N/A N/A May 18, 2022 1 Year May 18, 2022 1 Year Sep. 19, 2021 1 Year Jul. 22, 2022 1 Year Nov. 29, 2021 1 Year May 06, 2022 1 Year Sep. 02, 2021 1 Year Apr. 11, 2022 1 Year N/A N/A Sep. 02, 2021 1 Year Sep. 02, 2021 1 Year Sep. 02, 2021 1 Year Sep. 02, 2021 1 Year Sep. 02, 2021 1 Year Sep. 02, 2021 1 Year N/A N/A Page 10 of 86 Dongguan Dongdian Testing Service Co., Ltd. 4. Maximum Peak Output Power 4.1. Block diagram of test setup Report No.:DDT-R22072825-2E01 4.2. Limits For frequency hopping systems operating in the 2400-2483.5 MHz band employing at least 75 non-overlapping hopping channels, and all frequency hopping systems in the 5725-5850 MHz band: 1 watt. For all other frequency hopping systems in the 2400-2483.5 MHz band: 0.125 watts, the e.i.r.p shall not exceed 4W. 4.3. Test procedure (1) Connect EUT's antenna output to spectrum analyzer by RF cable. (2) Measure the maximum conducted output power of EUT by spectrum analyzer with PK detector and RBW=3 MHz (above 20 dB bandwidth of measured signal), VBW=10 MHz Note: The attenuator loss was inputted into spectrum analyzer as amplitude offset. Page 11 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 4.4. Test result Mode GFSK S/4-DQPSK 8DPSK Antenna ANT1 ANT1 ANT1 ANT1 ANT1 ANT1 ANT1 ANT1 ANT1 Freq. (MHz) 2402 2441 2480 2402 2441 2480 2402 2441 2480 Conducted Output Power (dBm) 2.10 1.86 1.24 2.06 1.75 1.13 0.68 0.79 -0.01 Limit (dBm) 21 21 21 21 21 21 21 21 21 Mode Antenna Freq. (MHz) EIRP (dBm) Limit (dBm) ANT1 2402 3.47 36 GFSK ANT1 2441 3.23 36 ANT1 2480 2.61 36 ANT1 2402 3.43 36 S/4-DQPSK ANT1 2441 3.12 36 ANT1 2480 2.50 36 ANT1 2402 2.05 36 8DPSK ANT1 2441 2.16 36 ANT1 2480 1.36 36 Note: EIRP (dBm)=Conducted Output Power (dBm)+ Antenna Gain (dBi) Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Page 12 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 4.5. Original test data DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 2DH5_Ant1_2402 Page 13 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 2DH5_Ant1_2441 2DH5_Ant1_2480 3DH5_Ant1_2402 Page 14 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 3DH5_Ant1_2441 3DH5_Ant1_2480 Page 15 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 5. 20 dB Bandwidth and 99% Bandwidth 5.1. Block diagram of test setup Same as section 4.1 5.2. Limits Intentional radiators operating under the alternative provisions to the general emission limits, as contained in § 15.217 through 15.257 and in Subpart E of this part, must be designed to ensure that the 20dB bandwidth of the emission, or whatever bandwidth may otherwise be specified in the specific rule section under which the equipment operates, is contained within the frequency band designated in the rule section under which the equipment is operated. 5.3. Test procedure (1) Connect EUT's antenna output to spectrum analyzer by RF cable. (2) The bandwidth of the fundamental frequency was measured by spectrum analyzer with 30 kHz RBW and 100 kHz VBW. The 20 dB bandwidth is defined as the total spectrum the power of which is higher than peak power minus 20 dB. 5.4. Test result Mode GFSK S/4-DQPSK 8DPSK Freq. (MHz) 2402 2441 2480 2402 2441 2480 2402 2441 2480 20 dB bandwidth Result (MHz) 1.032 1.026 0.975 1.275 1.269 1.311 1.251 1.158 1.257 99% bandwidth Result (MHz) 0.893 0.924 0.947 1.176 1.146 1.181 1.146 1.153 1.147 Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Page 16 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 5.5. Original test data 20dB bandwidth DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 Page 17 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 2DH5_Ant1_2402 2DH5_Ant1_2441 2DH5_Ant1_2480 Page 18 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 3DH5_Ant1_2402 3DH5_Ant1_2441 3DH5_Ant1_2480 Page 19 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 99% bandwidth: DH5_Ant1_2402 DH5_Ant1_2441 DH5_Ant1_2480 2DH5_Ant1_2402 Page 20 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 2DH5_Ant1_2441 2DH5_Ant1_2480 3DH5_Ant1_2402 Page 21 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 3DH5_Ant1_2441 3DH5_Ant1_2480 Page 22 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 6. Carrier Frequency Separation 6.1. Block diagram of test setup Same as section 4.1 6.2. Limits Frequency hopping systems shall have hopping channel carrier frequencies separated by a minimum of 25 kHz or the 20dB bandwidth of the hopping channel, whichever is greater. Alternatively, frequency hopping systems operating in the 2400-2483.5 MHz band may have hopping channel carrier frequencies that are separated by 25 kHz or two-thirds of the 20 dB bandwidth of the hopping channel, whichever is greater, provided the systems operate with an output power no greater than 125 mW. 6.3. Test procedure (1) Connect EUT's antenna output to spectrum analyzer by RF cable. (2) The carrier frequency was measured by spectrum analyzer with 100 kHz RBW and 300 kHz VBW. 6.4. Test result Mode GFSK S/4-DQPSK 8DPSK Channel separation (MHz) 1.164 1.000 1.002 20dB bandwidth (MHz) (worse case) 1.032 1.311 1.257 Limit (MHz) 2/3 of 20dB bandwidth 0.688 0.874 0.838 Verdict Pass Pass Pass Page 23 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 6.5. Original test data DH5_Ant1_Hop 2DH5_Ant1_Hop 3DH5_Ant1_Hop Page 24 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 7. Number of Hopping Channel 7.1. Block diagram of test setup Same as section 4.1 7.2. Limits Frequency hopping systems in the 2400-2483.5 MHz band shall use at least 15 channels. 7.3. Test procedure (1) Connect EUT's antenna output to spectrum analyzer by RF cable. (2) The number of hopping channels was measured by spectrum analyzer with 100 kHz RBW and 300 kHz VBW. 7.4. Test result Mode GFSK S/4-DQPSK 8DPSK Number of hopping channels 79 79 79 Limit >15 >15 >15 Verdict Pass Pass Pass Page 25 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 7.5. Original test data DH5_Ant1_Hop 2DH5_Ant1_Hop 3DH5_Ant1_Hop Page 26 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 8. Dwell Time 8.1. Block diagram of test setup Same as section 4.1 8.2. Limits The average time of occupancy on any channel shall not be greater than 0.4 seconds within a period of 0.4 seconds multiplied by the number of hopping channels employed. 8.3. Test procedure (1) Connect EUT's antenna output to spectrum analyzer by RF cable. (2) The test period: T= 0.4 Second/Channel x 79 Channel = 31.6 s (3) Measure the hopping number and on time of each pulse with spectrum analyzer in zero span set, and calculate dwell time with formula Dwell time = total hops *pulse's on time. 8.4. Test result Mode Dwell time (s) Pulse's on time (ms) DH1 0.060 0.40 DH3 0.165 1.65 DH5 0.212 2.90 2DH1 0.069 0.41 2DH3 0.164 1.66 2DH5 0.204 2.91 3DH1 0.069 0.41 3DH3 0.181 1.66 3DH5 0.201 2.91 Note: Dwell time = total hops *pulse's on time. Total hops 151 100 73 169 99 70 169 109 69 Limit <400ms <400ms <400ms <400ms <400ms <400ms <400ms <400ms <400ms Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Page 27 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 8.5. Original test data DH1_Ant1_Hop DH3_Ant1_Hop Page 28 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 DH5_Ant1_Hop 2DH1_Ant1_Hop Page 29 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 2DH3_Ant1_Hop Page 30 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 2DH5_Ant1_Hop 3DH1_Ant1_Hop Page 31 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 3DH3_Ant1_Hop Page 32 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 3DH5_Ant1_Hop Page 33 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 9. Band Edge Compliance (Conducted Method) 9.1. Block diagram of test setup Same as section 4.1 9.2. Limit All restriction band should comply with 15.209, other emission should be at least 20dB below the fundamental. 9.3. Test procedure (1) Connect EUT's antenna output to spectrum analyzer by RF cable. (2) Establish a reference level by using the following procedure: RBW: 100 kHz VBW: 300 kHz Span Encompass frequency range to be measured Detector Mode: Peak Sweep time: auto Trace mode Max hold (3) Allow the trace to stabilize, use the peak marker function to determine the maximum peak power level to establish the reference level. 9.4. Test result Mode GFSK S/4-DQPSK 8DPSK Freq. (MHz) Hopping off 2402 Hopping off 2480 Hopping on Hopping off 2402 Hopping off 2480 Hopping on Hopping off 2402 Hopping off 2480 Hopping on Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass Page 34 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 9.5. Original test data DH5_Ant1_Low_2402 DH5_Ant1_High_2480 DH5_Ant1_Low_Hop_2402 DH5_Ant1_High_Hop_2480 Page 35 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 2DH5_Ant1_Low_2402 2DH5_Ant1_High_2480 2DH5_Ant1_Low_Hop_2402 Page 36 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 2DH5_Ant1_High_Hop_2480 3DH5_Ant1_Low_2402 3DH5_Ant1_High_2480 Page 37 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 3DH5_Ant1_Low_Hop_2402 3DH5_Ant1_High_Hop_2480 Page 38 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 10. Radiated Emission 10.1. Block diagram of test setup In 3m Anechoic Chamber, test setup diagram for 9kHz-30MHz: Semi-anechoic Chamber 3m EUT and Support System 1m 1.5m(L)*1.0m(W)*0.8m(H) Turntable EMI Test Receiver PC System In 3m Anechoic Chamber, test setup diagram for 30 MHz - 1 GHz: Semi-anechoic Chamber ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS 3m EUT and Support System 1.5m(L)*1.0m(W)*0.8m(H) Turntable EMI Test Receiver PC System Page 39 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 In 3m Anechoic Chamber, test setup diagram for frequency above 1GHz: Semi-anechoic Chamber ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS 3m 1.5m(L)*1.0m(W)*1.5m(H) EUT and Support System Turntable Pre-Amplifier EMI Test Receiver PC System Note: For harmonic emissions test an appropriate high pass filter was inserted in the input port of AMP. 10.2. Limit (1) FCC 15.205 Restricted frequency band MHz MHz MHz 0.090-0.110 16.42-16.423 10.495-0.505 16.69475-16.69525 2.1735-2.1905 16.80425-16.80475 4.125-4.128 25.5-25.67 4.1772&4.17775 37.5-38.25 4.2072&4.20775 73-74.6 6.215-6.218 74.8-75.2 6.26775-6.26825 108-121.94 6.31175-6.31225 123-138 8.291-8.294 149.9-150.05 8.362-8.366 156.52475-156.52525 8.37625-8.38675 156.7-156.9 8.41425-8.41475 162.0125-167.17 12.29-12.293 167.72-173.2 12.51975-12.52025 240-285 12.57675-12.57725 322-335.4 13.36-13.41 GHz 399.9-410 608-614 960-1240 1300-1427 1435-1626.5 1645.5-1646.5 1660-1710 1718.8-1722.2 2200-2300 2310-2390 2483.5-2500 2690-2900 3260-3267 3332-3339 3345.8-3358 3600-4400 4.5-5.15 5.35-5.46 7.25-7.75 8.025-8.5 9.0-9.2 9.3-9.5 10.6-12.7 13.25-13.4 14.47-14.5 15.35-16.2 17.7-21.4 22.01-23.12 23.6-24.0 31.2-31.8 36.43-36.5 (2) 1Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz. 2Above 38.6 Page 40 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 RSS-Gen section 8.10 Restricted frequency bands* MHz MHz MHz 0.090-0.110 12.51975-12.52025 0.495-0.505 12.57675-12.57725 2.1735-2.1905 13.36-13.41 3.020-3.026 16.42-16.423 4.125-4.128 16.69475-16.69525 4.1772&4.17775 16.80425-16.80475 4.2072&4.20775 25.5-25.67 5.677-5.683 37.5-38.25 6.215-6.218 73-74.6 6.26775-6.26825 74.8-75.2 6.31175-6.31225 108-138 8.291-8.294 149.9-150.05 8.362-8.366 156.52475-156.52525 8.37625-8.38675 156.7-156.9 8.41425-8.41475 162.0125-167.17 12.29-12.293 167.72-173.2 240-285 322-335.4 399.9-410 608-614 960-1427 1435-1626.5 1645.5-1646.5 1660-1710 1718.8-1722.2 2200-2300 2310-2390 2483.5-2500 2655-2900 3260-3267 3332-3339 3345.8-3358 GHz 3.5-4.4 4.5-5.15 5.35-5.46 7.25-7.75 8.025-8.5 9.0-9.2 9.3-9.5 10.6-12.7 13.25-13.4 14.47-14.5 15.35-16.2 17.7-21.4 22.01-23.12 23.6-24.0 31.2-31.8 36.43-36.5 Above 38.6 * Certain frequency bands listed in table and in bands above 38.6 GHz are designated for licence-exempt applications. These frequency bands and the requirements that apply to related devices are set out in the 200 and 300 series of RSSs. (2) FCC 15.209 Limit & RSS-Gen section 8.9 Limit FREQUENCY MHz DISTANCE Meters 0.009 ~ 0.490 300 0.490 ~ 1.705 30 1.705 ~ 30.0 30 30 ~ 88 3 88 ~ 216 3 216 ~ 960 3 960 ~ 1000 3 Above 1000 3 FIELD STRENGTHS LIMIT PV/m dB(PV)/m 2400/F(kHz) 67.6-20log(F) 24000/F(kHz) 87.6-20log(F) 30 29.54 100 40.0 150 43.5 200 46.0 500 54.0 74.0 dB(PV)/m (Peak) 54.0 dB(PV)/m (Average) Note: (1) The emission limits shown in the above table are based on measurements employing a CISPR QP detector except for the frequency bands 9 - 90 kHz, 110 - 490 kHz and above 1000 MHz, radiated emissions limits in these three bands are based on measurements employing an average detector. (2) At frequencies below 30 MHz, measurement may be performed at a distance closer than that specified, and the limit at closer measurement distance can be extrapolated by below formula: Limit3m(dBuV/m)= Limit30m(dBuV/m) + 40Log(30m/3m) (3) Limit for this EUT The emissions appearing within 15.205 restricted frequency bands shall not exceed the limits Page 41 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 shown in 15.209, and the emissions appearing within RSS-Gen section 8.10 Restricted frequency bands shall not exceed the limits shown in RSS-Gen section 8.9, all the other emissions shall be at least 20 dB below the fundamental emissions or comply with 15.209 limits and RSS-Gen section 8.9 limits. 10.3. Test Procedure (1) EUT was placed on a non-metallic table, 80 cm above the ground plane inside a semi-anechoic chamber for below 1G and 150 cm above the ground plane inside a fully-anechoic chamber for above 1G. (2) Test antenna was located 3 m from the EUT on an adjustable mast, and the antenna used as below table. Test frequency range 9kHz-30MHz 30MHz-1GHz 1GHz-18GHz 18GHz-40GHz Test antenna used Active Loop antenna Trilog Broadband Antenna Double Ridged Horn Antenna (1GHz-18GHz) Horn Antenna (18GHz-40GHz) Test antenna distance 3 m 3 m 3 m 1 m According ANSI C63.10:2013 clause 6.4.6 and 6.5.3, for measurements below 30 MHz, Antenna was located 3 m from EUT, the loop antenna was positioned in three antenna orientations (parallel, perpendicular, and round-parallel), for each measurement antenna alignment, the EUT shall be rotated through 0° to 360° on a turntable, and the lowest height of the magnetic antenna shall be 1 m above the ground. For measurement above 30 MHz, the trilog Broadband Antenna or Horn Antenna was located 3 m from EUT, Measurements were made with the antenna positioned in both the horizontal and vertical planes of Polarization, and the measurement antenna was varied from 1 m to 4 m. in height above the reference ground plane to obtain the maximum signal strength. (3) Below pre-scan procedure was first performed in order to find prominent frequency spectrum radiated emissions from 9 kHz to 25 GHz: (a) Scanning the peak frequency spectrum with the antenna specified in step (3), and the EUT was rotated 360 degree, the antenna height was varied from 1 m to 4 m (Except loop antenna, it's fixed 1 m above ground.) (b) Change work frequency or channel of device if practicable. (c) Change modulation type of device if practicable. (d) Change power supply range from 85% to 115% of the rated supply voltage (e) Rotated EUT though three orthogonal axes to determine the attitude of EUT arrangement produces highest emissions. Spectrum frequency from 9 kHz to 25 GHz (tenth harmonic of fundamental frequency) was investigated, and no any obvious emission were detected from 18 GHz to 25 GHz, so below Page 42 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 final test was performed with frequency range from 9 kHz to 18 GHz. (4) For final emissions measurements at each frequency of interest, the EUT was rotated and the antenna height was varied between 1m and 4m in order to maximize the emission. Measurements in both horizontal and vertical polarities were made and the data was recorded. In order to find the maximum emission, the relative positions of equipment and all of the interface cables were changed according to ANSI C63.10:2013 on Radiated Emission test. (5) The emissions from 9 kHz to 1 GHz were measured based on CISPR QP detector except for the frequency bands 9 - 90 kHz, 110 - 490 kHz, for emissions from 9 kHz - 90 kHz,110 kHz - 490 kHz and above 1 GHz were measured based on average detector, for emissions above 1 GHz, peak emissions also be measured and need comply with Peak limit. (6) The emissions from 9 kHz to 1 GHz, QP or average values were measured with EMI receiver with below RBW. Frequency band RBW 9 kHz-150 kHz 200 Hz 150 kHz-30 MHz 9 kHz 30 MHz-1 GHz 120 kHz (7) For emissions above 1GHz, both Peak and Average level were measured with Spectrum Analyzer, and the RBW is set at 1 MHz, VBW is set at 3 MHz for Peak measure; According ANSI C63.10:2013 clause 4.1.4.2.2 procedure for average measure. (8) X axis, Y axis, Z axis are tested, and worse setup X axis is reported. 10.4. Test result Pass. (See below detailed test result) All the emissions except fundamental emission from 9 kHz to 25 GHz were comply with 15.209 limits and RSS-Gen section 8.9 limits. Note1: According exploratory test, the emission levels are 20 dB below the limit detected from 9 kHz to 30 MHz and 18 GHz to 25 GHz, so the final test was performed with frequency range from 30 MHz to 18 GHz and recorded in below. Note2: 30 MHz ~ 25 GHz: (Scan with GFSK, S/4-DQPSK and 8DPSK, the worst case is GFSK Mode) Note3: For emissions below 1 GHz, according exploratory explorer test, when change Tx mode and channel, have no distinct influence on emissions level, so for emissions below 1 GHz, the final test was only performed with EUT working in GFSK, Tx 2402 MHz mode. Note4: For emissions above 1 GHz. If peak results comply with AV limit, AV Result is deemed to comply with AV limit. Page 43 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 Radiated Emission test (below 1 GHz) TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-16 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC BELOW 1G.EM6 Tested By : James Gan EUT : Bluetooth Headset Model Number : TOUR ONE M2 Power Supply : Battery Test Mode : Tx mode Condition : Temp:24.7°C,Humi:55.5%,Press:100.3kPa Antenna/Distance : 2022 9161 #3/3m/HORIZONTAL Memo : Data: 1 Item (Mark) 1 2 3 4 5 6 Freq. (MHz) 33.21 61.78 111.74 317.70 790.62 955.44 Read Level (dBV) 43.66 41.98 42.38 37.73 26.91 25.03 Antenna Factor (dB/m) 11.34 11.67 12.55 13.31 21.61 23.50 Cable Loss dB 3.57 3.76 4.06 4.89 6.20 6.60 Result Level (dBV/m) 26.28 25.14 26.77 23.60 21.93 23.56 Limit Line (dBV/m) 40.00 40.00 43.50 46.00 46.00 46.00 Over Limit (dB) -13.72 -14.86 -16.73 -22.40 -24.07 -22.44 Detector QP QP QP QP QP QP Polarization HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss. 2. If Peak Result complies with QP limit, QP Result is deemed to comply with QP limit. 3. Test setup: RBW: 120 kHz, VBW: 300 kHz, Sweep time: auto. Page 44 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-16 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC BELOW 1G.EM6 Tested By : James Gan EUT : Bluetooth Headset Model Number : TOUR ONE M2 Power Supply : Battery Test Mode : Tx mode Condition : Temp:24.7°C,Humi:55.5%,Press:100.3kPa Antenna/Distance : 2022 9161 #3/3m/VERTICAL Memo : Data: 2 Item (Mark) 1 2 3 4 5 6 Freq. (MHz) 34.04 61.56 148.96 332.52 616.37 982.62 Read Level (dBV) 43.26 41.03 40.17 33.12 25.31 24.69 Antenna Factor (dB/m) 11.50 11.73 16.79 13.75 19.40 23.80 Cable Loss dB 3.58 3.76 4.25 4.94 5.78 6.75 Result Level (dBV/m) 26.05 24.25 29.03 19.46 17.75 23.99 Limit Line (dBV/m) 40.00 40.00 43.50 46.00 46.00 54.00 Over Limit (dB) -13.95 -15.75 -14.47 -26.54 -28.25 -30.01 Detector QP QP QP QP QP QP Note: 1. Result Level = Read Level + Antenna Factor + Cable loss. 2. If Peak Result complies with QP limit, QP Result is deemed to comply with QP limit. 3. Test setup: RBW: 120 kHz, VBW: 300 kHz, Sweep time: auto. Polarization VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL Page 45 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 Radiated Emission test (above 1 GHz) TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-11 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Model Number : TOUR ONE M2 Power Supply : Battery Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Test Mode : Tx mode Antenna/Distance : 2021 BBHA 9120D 3#/3m/HORIZONTAL Memo : DH5 2402 Data: 1 Item (Mark) 1 2 3 4 5 6 Freq. (MHz) 1082.00 1340.00 1596.00 1954.00 2744.00 2966.00 Read Level (dBV) 50.36 50.60 51.67 50.42 50.94 50.74 Antenna Factor (dB/m) 25.48 25.43 25.65 26.58 28.53 29.37 PRM Factor dB 38.02 38.41 38.79 39.33 39.77 39.88 Cable Loss dB 1.15 1.29 1.42 1.58 1.80 1.86 Filter Factor dB 0.51 0.56 0.61 0.67 0.76 0.79 Result Level (dBV/m) 39.48 39.47 40.56 39.92 42.26 42.88 Limit Line (dBV/m) 74.00 74.00 74.00 74.00 74.00 74.00 Over Limit (dB) -34.52 -34.53 -33.44 -34.08 -31.74 -31.12 Detector Polarization Peak Peak Peak Peak Peak Peak HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 46 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-10 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Power Supply : Battery Model Number Test Mode : TOUR ONE M2 : Tx mode Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL Memo : DH5 2402 Data: 2 Item (Mark) 1 2 3 4 5 6 Freq. (MHz) 1096.00 1344.00 1596.00 1970.00 2198.00 2992.00 Read Level (dBV) 50.69 50.54 54.96 51.14 52.05 50.30 Antenna Factor (dB/m) 25.48 25.43 25.65 26.62 27.06 29.47 PRM Factor dB 38.04 38.42 38.79 39.36 39.50 39.90 Cable Loss dB 1.15 1.29 1.42 1.59 1.66 1.87 Filter Factor dB 0.52 0.56 0.61 0.67 0.70 0.79 Result Level (dBV/m) 39.80 39.40 43.85 40.66 41.97 42.53 Limit Line (dBV/m) 74.00 74.00 74.00 74.00 74.00 74.00 Over Limit (dB) -34.20 -34.60 -30.15 -33.34 -32.03 -31.47 Detector Peak Peak Peak Peak Peak Peak Polarization VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 47 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-10 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Model Number : TOUR ONE M2 Power Supply : Battery Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Test Mode : Tx mode Antenna/Distance : 2021 BBHA 9120D 3#/3m/HORIZONTAL Memo : DH5 2441 Data: 3 Item (Mark) 1 2 3 4 5 6 Freq. (MHz) 1084.00 1442.00 1902.00 2392.00 2670.00 2890.00 Read Level (dBV) 50.85 50.54 51.02 52.33 50.02 50.89 Antenna Factor (dB/m) 25.48 25.41 26.45 27.41 28.25 29.08 PRM Factor dB 38.03 38.56 39.25 39.60 39.74 39.85 Cable Loss dB 1.15 1.35 1.56 1.71 1.78 1.84 Filter Factor dB 0.52 0.58 0.66 0.72 0.75 0.78 Result Level (dBV/m) 39.97 39.32 40.44 42.57 41.06 42.74 Limit Line (dBV/m) 74.00 74.00 74.00 74.00 74.00 74.00 Over Limit (dB) -34.03 -34.68 -33.56 -31.43 -32.94 -31.26 Detector Polarization Peak Peak Peak Peak Peak Peak HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 48 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-10 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Power Supply : Battery Model Number Test Mode : TOUR ONE M2 : Tx mode Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL Memo : DH5 2441 Data: 4 Item (Mark) 1 2 3 4 5 6 Freq. (MHz) 1216.00 1594.00 1914.00 2398.00 2652.00 2974.00 Read Level (dBV) 50.80 54.91 50.73 53.40 50.73 50.46 Antenna Factor (dB/m) 25.46 25.64 26.48 27.42 28.18 29.40 PRM Factor dB 38.22 38.79 39.27 39.60 39.73 39.89 Cable Loss dB 1.22 1.42 1.56 1.71 1.78 1.86 Filter Factor dB 0.54 0.61 0.66 0.72 0.75 0.79 Result Level (dBV/m) 39.80 43.79 40.16 43.65 41.71 42.62 Limit Line (dBV/m) 74.00 74.00 74.00 74.00 74.00 74.00 Over Limit (dB) -34.20 -30.21 -33.84 -30.35 -32.29 -31.38 Detector Peak Peak Peak Peak Peak Peak Polarization VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 49 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-11 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Model Number : TOUR ONE M2 Power Supply : Battery Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Test Mode : Tx mode Antenna/Distance : 2021 BBHA 9120D 3#/3m/HORIZONTAL Memo : DH5 2480 Data: 5 Item (Mark) 1 2 3 4 5 6 Freq. (MHz) 1152.00 1594.00 1838.00 2410.00 2636.00 2976.00 Read Level (dBV) 55.48 51.31 50.86 52.37 53.42 50.73 Antenna Factor (dB/m) 25.47 25.64 26.28 27.44 28.12 29.41 PRM Factor dB 38.13 38.79 39.16 39.61 39.72 39.89 Cable Loss dB 1.19 1.42 1.53 1.71 1.78 1.86 Filter Factor dB 0.53 0.61 0.65 0.73 0.75 0.79 Result Level (dBV/m) 44.54 40.19 40.16 42.64 44.35 42.90 Limit Line (dBV/m) 74.00 74.00 74.00 74.00 74.00 74.00 Over Limit (dB) -29.46 -33.81 -33.84 -31.36 -29.65 -31.10 Detector Polarization Peak Peak Peak Peak Peak Peak HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 50 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-11 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Power Supply : Battery Model Number Test Mode : TOUR ONE M2 : Tx mode Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL Memo : DH5 2480 Data: 6 Item (Mark) 1 2 3 4 5 6 Freq. (MHz) 1334.00 1592.00 2050.00 2390.00 2738.00 2952.00 Read Level (dBV) 51.26 54.22 50.81 57.04 50.35 50.49 Antenna Factor (dB/m) 25.43 25.64 26.79 27.40 28.50 29.32 PRM Factor dB 38.40 38.79 39.43 39.60 39.77 39.88 Cable Loss dB 1.29 1.42 1.61 1.71 1.80 1.86 Filter Factor dB 0.56 0.61 0.69 0.72 0.76 0.78 Result Level (dBV/m) 40.14 43.10 40.47 47.27 41.64 42.57 Limit Line (dBV/m) 74.00 74.00 74.00 74.00 74.00 74.00 Over Limit (dB) -33.86 -30.90 -33.53 -26.73 -32.36 -31.43 Detector Peak Peak Peak Peak Peak Peak Polarization VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 51 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-11 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Model Number : TOUR ONE M2 Power Supply : Battery Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Test Mode : Tx mode Antenna/Distance : 2021 BBHA 9120D 3#/3m/HORIZONTAL Memo : DH5 2402 Data: 7 Item (Mark) 1 2 3 4 5 6 7 Freq. (MHz) 4845.00 7830.00 9660.00 13095.00 13095.00 14310.00 17970.00 Read Level (dBV) 49.65 47.70 47.84 46.28 39.11 44.61 42.03 Antenna Factor (dB/m) 32.60 36.80 38.60 39.68 39.68 39.90 42.31 PRM Factor dB 40.37 39.78 40.36 40.33 40.33 39.67 40.68 Cable Loss dB 2.48 3.17 3.64 4.32 4.32 4.42 4.95 Filter Factor dB 2.17 2.28 2.38 2.95 2.95 2.81 3.78 Result Level (dBV/m) 46.53 50.17 52.10 52.90 45.73 52.07 52.39 Limit Line (dBV/m) 74.00 74.00 74.00 74.00 54.00 74.00 74.00 Over Limit (dB) -27.47 -23.83 -21.90 -21.10 -8.27 -21.93 -21.61 Detector Polarization Peak Peak Peak Peak Average Peak Peak HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 52 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-10 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Power Supply : Battery Model Number Test Mode : TOUR ONE M2 : Tx mode Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL Memo : DH5 2402 Data: 8 Item (Mark) 1 2 3 4 5 6 Freq. (MHz) 4050.00 8700.00 12375.00 13440.00 15270.00 17955.00 Read Level (dBV) 49.87 46.91 46.25 45.00 43.81 41.24 Antenna Factor (dB/m) 31.14 38.00 39.05 39.95 39.12 42.22 PRM Factor dB 40.21 39.87 40.21 40.09 39.68 40.67 Cable Loss dB 2.13 3.26 3.80 4.04 4.52 4.95 Filter Factor dB 2.05 2.21 2.61 2.93 2.75 3.78 Result Level (dBV/m) 44.98 50.51 51.50 51.83 50.52 51.52 Limit Line (dBV/m) 74.00 74.00 74.00 74.00 74.00 74.00 Over Limit (dB) -29.02 -23.49 -22.50 -22.17 -23.48 -22.48 Detector Peak Peak Peak Peak Peak Peak Polarization VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 53 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-11 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Model Number : TOUR ONE M2 Power Supply : Battery Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Test Mode : Tx mode Antenna/Distance : 2021 BBHA 9120D 3#/3m/HORIZONTAL Memo : DH5 2441 Data: 9 Item (Mark) 1 2 3 4 5 6 7 Freq. (MHz) 5910.00 8835.00 11625.00 13920.00 13920.00 16965.00 17955.00 Read Level (dBV) 47.83 46.76 46.28 44.96 37.69 43.25 41.24 Antenna Factor (dB/m) 33.78 38.13 39.05 39.92 39.92 38.46 42.22 PRM Factor dB 40.49 39.88 40.14 39.76 39.76 40.09 40.67 Cable Loss dB 2.95 3.29 3.99 4.44 4.44 4.71 4.95 Filter Factor dB 2.75 2.20 2.39 2.90 2.90 3.50 3.78 Result Level (dBV/m) 46.82 50.50 51.57 52.46 45.19 49.83 51.52 Limit Line (dBV/m) 74.00 74.00 74.00 74.00 54.00 74.00 74.00 Over Limit (dB) -27.18 -23.50 -22.43 -21.54 -8.81 -24.17 -22.48 Detector Polarization Peak Peak Peak Peak Average Peak Peak HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 54 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-11 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Power Supply : Battery Model Number Test Mode : TOUR ONE M2 : Tx mode Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL Memo : DH5 2441 Data: 10 Item (Mark) 1 2 3 4 5 6 7 Freq. (MHz) 4995.00 7935.00 10950.00 13605.00 13605.00 15030.00 17970.00 Read Level (dBV) 48.11 47.68 46.24 45.53 38.53 43.78 42.19 Antenna Factor (dB/m) 33.08 36.92 39.27 39.98 39.98 39.46 42.31 PRM Factor dB 40.40 39.79 40.22 39.98 39.98 39.61 40.68 Cable Loss dB 2.54 3.18 3.79 4.10 4.10 4.48 4.95 Filter Factor dB 2.19 2.28 2.39 2.92 2.92 2.63 3.78 Result Level (dBV/m) 45.52 50.27 51.47 52.55 45.55 50.74 52.55 Limit Line (dBV/m) 74.00 74.00 74.00 74.00 54.00 74.00 74.00 Over Limit (dB) -28.48 -23.73 -22.53 -21.45 -8.45 -23.26 -21.45 Detector Peak Peak Peak Peak Average Peak Peak Polarization VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 55 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-11 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Model Number : TOUR ONE M2 Power Supply : Battery Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Test Mode : Tx mode Antenna/Distance : 2021 BBHA 9120D 3#/3m/HORIZONTAL Memo : DH5 2480 Data: 11 Item (Mark) 1 2 3 4 5 6 7 Freq. (MHz) 5100.00 7545.00 9885.00 11760.00 14595.00 14595.00 17955.00 Read Level (dBV) 49.22 47.62 47.42 46.71 45.25 38.64 41.88 Antenna Factor (dB/m) 33.04 36.45 38.47 39.10 39.82 39.82 42.22 PRM Factor dB 40.41 39.75 40.52 40.12 39.64 39.64 40.67 Cable Loss dB 2.55 3.14 3.66 4.01 4.37 4.37 4.95 Filter Factor dB 2.25 2.27 2.45 2.40 2.73 2.73 3.78 Result Level (dBV/m) 46.65 49.73 51.48 52.10 52.53 45.92 52.16 Limit Line (dBV/m) 74.00 74.00 74.00 74.00 74.00 54.00 74.00 Over Limit (dB) -27.35 -24.27 -22.52 -21.90 -21.47 -8.08 -21.84 Detector Polarization Peak Peak Peak Peak Peak Average Peak HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL HORIZONTAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 56 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-11 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Power Supply : Battery Model Number Test Mode : TOUR ONE M2 : Tx mode Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL Memo : DH5 2480 Data: 12 Item (Mark) 1 2 3 4 5 6 7 Freq. (MHz) 4920.00 7830.00 10950.00 13485.00 13485.00 15705.00 17970.00 Read Level (dBV) 48.42 47.00 46.16 45.23 38.89 44.84 40.72 Antenna Factor (dB/m) 32.84 36.80 39.27 39.99 39.99 38.43 42.31 PRM Factor dB 40.38 39.78 40.22 40.06 40.06 39.81 40.68 Cable Loss dB 2.51 3.17 3.79 4.00 4.00 4.58 4.95 Filter Factor dB 2.18 2.28 2.39 2.93 2.93 2.97 3.78 Result Level (dBV/m) 45.57 49.47 51.39 52.09 45.75 51.01 51.08 Limit Line (dBV/m) 74.00 74.00 74.00 74.00 54.00 74.00 74.00 Over Limit (dB) -28.43 -24.53 -22.61 -21.91 -8.25 -22.99 -22.92 Detector Peak Peak Peak Peak Average Peak Peak Polarization VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL VERTICAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 57 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 11. RF Conducted Spurious Emissions 11.1. Block diagram of test setup Same as section 4.1 11.2. Limits In any 100 kHz bandwidth outside the frequency bands in which the spread spectrum intentional radiator in operating, the radio frequency power that is produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the desired power. 11.3. Test procedure (1) Connect EUT's antenna output to spectrum analyzer by RF cable. (2) Establish a reference level by using the following procedure: Center frequency Test frequency RBW: 100 kHz VBW: 300 kHz Span Wide enough to capture the peak level of the in-band emission Detector Mode: Peak Sweep time: auto Trace mode Max hold (3) Allow the trace to stabilize, use the peak marker function to determine the maximum peak power level to establish the reference level. (4) Set the spectrum analyzer as follows: RBW: 100 kHz VBW: 300 kHz Span Encompass frequency range to be measured Number of measurement points span/RBW Detector Mode: Peak Sweep time: auto Trace mode Max hold (5) Allow the trace to stabilize, use the peak marker function to determine the maximum amplitude of all unwanted emissions outside of the authorized frequency band Page 58 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 11.4. Test result Mode GFSK S/4-DQPSK 8DPSK Freq. (MHz) Hopping off 2402 Hopping off 2441 Hopping off 2480 Hopping off 2402 Hopping off 2441 Hopping off 2480 Hopping off 2402 Hopping off 2441 Hopping off 2480 11.5. Original test data DH5_Ant1_2402_0~Reference Verdict Pass Pass Pass Pass Pass Pass Pass Pass Pass DH5_Ant1_2402_30~1000 DH5_Ant1_2402_1000~26500 Page 59 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 DH5_Ant1_2441_0~Reference DH5_Ant1_2441_30~1000 DH5_Ant1_2441_1000~26500 Page 60 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 DH5_Ant1_2480_0~Reference DH5_Ant1_2480_30~1000 DH5_Ant1_2480_1000~26500 Page 61 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 2DH5_Ant1_2402_0~Reference 2DH5_Ant1_2402_30~1000 2DH5_Ant1_2402_1000~26500 Page 62 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 2DH5_Ant1_2441_0~Reference 2DH5_Ant1_2441_30~1000 2DH5_Ant1_2441_1000~26500 Page 63 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 2DH5_Ant1_2480_0~Reference 2DH5_Ant1_2480_30~1000 2DH5_Ant1_2480_1000~26500 Page 64 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 3DH5_Ant1_2402_0~Reference 3DH5_Ant1_2402_30~1000 3DH5_Ant1_2402_1000~26500 Page 65 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 3DH5_Ant1_2441_0~Reference 3DH5_Ant1_2441_30~1000 3DH5_Ant1_2441_1000~26500 Page 66 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 3DH5_Ant1_2480_0~Reference 3DH5_Ant1_2480_30~1000 3DH5_Ant1_2480_1000~26500 Page 67 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 Page 68 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 12. Band Edge Compliance (Radiated Method) 12.1. Block diagram of test setup In 3m Anechoic Chamber, test setup diagram for frequency above 1GHz: Semi-anechoic Chamber ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS 3m 1.5m(L)*1.0m(W)*1.5m(H) EUT and Support System Turntable Pre-Amplifier EMI Test Receiver PC System 12.2. Limit All restriction band should comply with 15.209 and RSS-Gen section 8.9 limits, other emission should be at least 20dB below the fundamental. 12.3. Test Procedure Same with clause 10.3 except change investigated frequency range from 2310 MHz to 2410 MHz and 2475 MHz to 2500 MHz. Remark: All restriction band have been tested, and only the worst case is shown in report. 12.4. Test result Pass. (See below detailed test result) Remark: hopping on and hopping off mode all have been test, hopping off mode is worse and reported only. Scan with all mode, the worst case is recorded in this report. The final test was only performed with EUT working in Left side Tx mode. Page 69 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-11 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Model Number : TOUR ONE M2 Power Supply : Battery Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Test Mode : Tx Mode Antenna/Distance : 2021 BBHA 9120D 3#/3m/HORIZONTAL Memo : DH5 2402 Data: 37 Item (Mark) 1 2 Freq. (MHz) 2334.90 2390.00 Read Level (dBV) 50.60 48.29 Antenna Factor (dB/m) 27.30 27.40 PRM Factor dB 39.57 39.60 Cable Loss dB 1.69 1.71 Filter Factor dB 0.72 0.72 Result Level (dBV/m) 40.74 38.52 Limit Line (dBV/m) 74.00 74.00 Over Limit (dB) -33.26 -35.48 Detector Polarization Peak Peak HORIZONTAL HORIZONTAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 70 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-11 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Power Supply : Battery Model Number Test Mode : TOUR ONE M2 : Tx mode Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL Memo : DH5 2402 Data: 38 Item (Mark) 1 2 Freq. (MHz) 2362.80 2390.00 Read Level (dBV) 53.97 51.08 Antenna Factor (dB/m) 27.35 27.40 PRM Factor dB 39.58 39.60 Cable Loss dB 1.70 1.71 Filter Factor dB 0.72 0.72 Result Level (dBV/m) 44.16 41.31 Limit Line (dBV/m) 74.00 74.00 Over Limit (dB) -29.84 -32.69 Detector Peak Peak Polarization VERTICAL VERTICAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 71 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-11 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Model Number : TOUR ONE M2 Power Supply : Battery Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Test Mode : Tx mode Antenna/Distance : 2021 BBHA 9120D 3#/3m/HORIZONTAL Memo : DH5 2480 Data: 43 Item (Mark) 1 2 Freq. (MHz) 2483.50 2495.25 Read Level (dBV) 46.26 48.68 Antenna Factor (dB/m) 27.57 27.59 PRM Factor dB 39.64 39.65 Cable Loss dB 1.74 1.74 Filter Factor dB 0.73 0.73 Result Level (dBV/m) 36.66 39.09 Limit Line (dBV/m) 74.00 74.00 Over Limit (dB) -37.34 -34.91 Detector Polarization Peak Peak HORIZONTAL HORIZONTAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 72 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-11 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Power Supply : Battery Model Number Test Mode : TOUR ONE M2 : Tx mode Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL Memo : DH5 2480 Data: 44 Item (Mark) 1 2 Freq. (MHz) 2483.50 2492.58 Read Level (dBV) 48.15 50.14 Antenna Factor (dB/m) 27.57 27.59 PRM Factor dB 39.64 39.65 Cable Loss dB 1.74 1.74 Filter Factor dB 0.73 0.73 Result Level (dBV/m) 38.55 40.55 Limit Line (dBV/m) 74.00 74.00 Over Limit (dB) -35.45 -33.45 Detector Peak Peak Polarization VERTICAL VERTICAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 73 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-11 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Model Number : TOUR ONE M2 Power Supply : Battery Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Test Mode : Tx mode Antenna/Distance : 2021 BBHA 9120D 3#/3m/HORIZONTAL Memo : 2DH5 2402 Data: 39 Item (Mark) 1 2 Freq. (MHz) 2321.20 2390.00 Read Level (dBV) 50.39 49.05 Antenna Factor (dB/m) 27.28 27.40 PRM Factor dB 39.56 39.60 Cable Loss dB 1.69 1.71 Filter Factor dB 0.72 0.72 Result Level (dBV/m) 40.52 39.28 Limit Line (dBV/m) 74.00 74.00 Over Limit (dB) -33.48 -34.72 Detector Polarization Peak Peak HORIZONTAL HORIZONTAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 74 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-11 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Power Supply : Battery Model Number Test Mode : TOUR ONE M2 : Tx mode Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL Memo : 2DH5 2402 Data: 40 Item (Mark) 1 2 Freq. (MHz) 2351.40 2390.00 Read Level (dBV) 53.68 50.03 Antenna Factor (dB/m) 27.33 27.40 PRM Factor dB 39.58 39.60 Cable Loss dB 1.70 1.71 Filter Factor dB 0.72 0.72 Result Level (dBV/m) 43.85 40.26 Limit Line (dBV/m) 74.00 74.00 Over Limit (dB) -30.15 -33.74 Detector Peak Peak Polarization VERTICAL VERTICAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 75 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-11 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Model Number : TOUR ONE M2 Power Supply : Battery Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Test Mode : Tx mode Antenna/Distance : 2021 BBHA 9120D 3#/3m/HORIZONTAL Memo : 2DH5 2480 Data: 45 Item (Mark) 1 2 Freq. (MHz) 2483.50 2492.13 Read Level (dBV) 46.58 48.78 Antenna Factor (dB/m) 27.57 27.59 PRM Factor dB 39.64 39.65 Cable Loss dB 1.74 1.74 Filter Factor dB 0.73 0.73 Result Level (dBV/m) 36.98 39.19 Limit Line (dBV/m) 74.00 74.00 Over Limit (dB) -37.02 -34.81 Detector Polarization Peak Peak HORIZONTAL HORIZONTAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 76 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-11 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Power Supply : Battery Model Number Test Mode : TOUR ONE M2 : Tx mode Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL Memo : 2DH5 2480 Data: 46 Item (Mark) 1 2 Freq. (MHz) 2483.50 2495.08 Read Level (dBV) 47.39 48.84 Antenna Factor (dB/m) 27.57 27.59 PRM Factor dB 39.64 39.65 Cable Loss dB 1.74 1.74 Filter Factor dB 0.73 0.73 Result Level (dBV/m) 37.79 39.25 Limit Line (dBV/m) 74.00 74.00 Over Limit (dB) -36.21 -34.75 Detector Peak Peak Polarization VERTICAL VERTICAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 77 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-11 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Model Number : TOUR ONE M2 Power Supply : Battery Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Test Mode : Tx mode Antenna/Distance : 2021 BBHA 9120D 3#/3m/HORIZONTAL Memo : 3DH5 2402 Data: 41 Item (Mark) 1 2 Freq. (MHz) 2325.10 2390.00 Read Level (dBV) 50.75 49.67 Antenna Factor (dB/m) 27.29 27.40 PRM Factor dB 39.56 39.60 Cable Loss dB 1.69 1.71 Filter Factor dB 0.72 0.72 Result Level (dBV/m) 40.89 39.90 Limit Line (dBV/m) 74.00 74.00 Over Limit (dB) -33.11 -34.10 Detector Polarization Peak Peak HORIZONTAL HORIZONTAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 78 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-11 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Power Supply : Battery Model Number Test Mode : TOUR ONE M2 : Tx mode Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL Memo : 3DH5 2402 Data: 42 Item (Mark) 1 2 Freq. (MHz) 2380.00 2390.00 Read Level (dBV) 54.27 49.56 Antenna Factor (dB/m) 27.38 27.40 PRM Factor dB 39.59 39.60 Cable Loss dB 1.71 1.71 Filter Factor dB 0.72 0.72 Result Level (dBV/m) 44.49 39.79 Limit Line (dBV/m) 74.00 74.00 Over Limit (dB) -29.51 -34.21 Detector Peak Peak Polarization VERTICAL VERTICAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 79 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-11 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Model Number : TOUR ONE M2 Power Supply : Battery Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Test Mode : Tx mode Antenna/Distance : 2021 BBHA 9120D 3#/3m/HORIZONTAL Memo : 3DH5 2480 Data: 47 Item (Mark) 1 2 Freq. (MHz) 2483.50 2488.33 Read Level (dBV) 47.77 48.91 Antenna Factor (dB/m) 27.57 27.58 PRM Factor dB 39.64 39.64 Cable Loss dB 1.74 1.74 Filter Factor dB 0.73 0.73 Result Level (dBV/m) 38.17 39.32 Limit Line (dBV/m) 74.00 74.00 Over Limit (dB) -35.83 -34.68 Detector Polarization Peak Peak HORIZONTAL HORIZONTAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 80 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-009 Radiated Emission Test Result Test Site Test Date : DDT 3m Chamber 3# : 2022-08-11 D:\E3 6.111\2022 Report Data\Q22072825-2E TOUR\TOURONE M2\ALL\FCC ABOVE 1G .EM6 Tested By : James Gan EUT : Bluetooth Headset Power Supply : Battery Model Number Test Mode : TOUR ONE M2 : Tx mode Condition : Temp:23.3°C,Humi:57.7%,Press:100.3kPa Antenna/Distance : 2021 BBHA 9120D 3#/3m/VERTICAL Memo : 3DH5 2480 Data: 48 Item (Mark) 1 2 Freq. (MHz) 2483.50 2487.85 Read Level (dBV) 47.73 49.01 Antenna Factor (dB/m) 27.57 27.58 PRM Factor dB 39.64 39.64 Cable Loss dB 1.74 1.74 Filter Factor dB 0.73 0.73 Result Level (dBV/m) 38.13 39.42 Limit Line (dBV/m) 74.00 74.00 Over Limit (dB) -35.87 -34.58 Detector Polarization Peak Peak HORIZONTAL HORIZONTAL Note: 1. Result Level = Read Level + Antenna Factor + Cable loss + Filter Factor - PRM Factor. 2. If Peak Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 1 MHz, VBW: 3 MHz, Sweep time: auto. Page 81 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 13. Power Line Conducted Emission 13.1. Block diagram of test setup Shield Room PC System 10cm EUT AE 80cm i Receiver LISN 1 80cm 50 impedance LISN 2 13.2. Power line conducted emission limits Frequency 150 kHz ~ 500 kHz 500 kHz ~ 5 MHz 5 MHz ~ 30 MHz Quasi-Peak Level dB(PV) 66 ~ 56* 56 60 Average Level dB(PV) 56 ~ 46* 46 50 Note 1: * Decreasing linearly with logarithm of frequency. Note 2: The lower limit shall apply at the transition frequencies. 13.3. Test procedure The EUT and Support equipment, if needed, were put placed on a non-metallic table, 80cm above the ground plane. Configuration EUT to simulate typical usage as described in clause 2.4 and test equipment as described in clause 10.2 of this report. All I/O cables were positioned to simulate typical actual usage as per ANSI C63.10. All support equipment power received from a second LISN. Emissions were measured on each current carrying line of the EUT using an EMI Test Receiver connected to the LISN powering the EUT. The Receiver scanned from 150 kHz to 30MHz for emissions in each of the test modes. During the above scans, the emissions were maximized by cable manipulation. The test mode(s) described in clause 2.4 were scanned during the preliminary test. After the preliminary scan, we found the test mode producing the highest emission level. The EUT configuration and worse cable configuration of the above highest emission levels were recorded for reference of the final test. EUT and support equipment were set up on the test bench as per the configuration with highest Page 82 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 emission level in the preliminary test. A scan was taken on both power lines, Neutral and Line, recording at least the six highest emissions. Emission frequency and amplitude were recorded into a computer in which correction factors were used to calculate the emission level and compare reading to the applicable limit. The test data of the worst-case condition(s) was recorded. The bandwidth of test receiver is set at 9 kHz. 13.4. Test result Pass. (See below detailed test result) Note1: All emissions not reported below are too low against the prescribed limits. Note2: "-----" means Peak detection; "-----" means Average detection. Note3: Pre-test AC conducted emission at both voltage AC 120V/60Hz and AC 240V/50Hz, recorded worse case. Page 83 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-010 Conducted Emission Test Result Test Site Test Date EUT Power Supply Condition Memo : DDT 1# Shield Room : 2022-08-16 : Bluetooth Headset : AC 120V/60Hz D:\2022 CE report date\Q22072825-2E JBL TOUR ONE2\FCC.EM6 Tested By : Bairong Model Number : TOUR ONE M2 Test Mode : Tx mode : TEMP:23.8°C, RH:62.0%, BP:101.2kPa LISN : : 2021 1# ENV216/NEUTRAL Data: 2 Item (Mark) 1 2 3 4 5 6 7 8 9 10 11 12 Freq. (MHz) 0.16 0.16 0.20 0.20 0.68 0.68 1.85 1.85 2.66 2.66 11.38 11.38 Read Level (dBV) 18.39 -0.24 16.64 -0.14 13.63 5.59 6.35 -3.14 5.75 -3.16 11.94 3.34 LISN Factor (dB) 9.80 9.80 9.80 9.80 9.78 9.78 9.61 9.61 9.68 9.68 9.74 9.74 Cable Loss (dB) 0.01 0.01 0.01 0.01 0.02 0.02 0.04 0.04 0.05 0.05 0.12 0.12 Pulse Limiter Factor (dB) 9.92 9.92 9.92 9.92 9.91 9.91 9.89 9.89 9.90 9.90 9.94 9.94 Result Level (dBV) 38.12 19.49 36.37 19.59 33.34 25.30 25.89 16.40 25.38 16.47 31.74 23.14 Limit Line (dBV) 65.56 55.56 63.76 53.76 56.00 46.00 56.00 46.00 56.00 46.00 60.00 50.00 Over Limit (dB) -27.44 -36.07 -27.39 -34.17 -22.66 -20.70 -30.11 -29.60 -30.62 -29.53 -28.26 -26.86 Detector QP Average QP Average QP Average QP Average QP Average QP Average Note: 1. Result Level = Read Level +LISN Factor + Pulse Limiter Factor + Cable loss. 2. If QP Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 200 Hz (9 kHz--150 kHz), 9 kHz (150 kHz--30 MHz). 4. Step size: 80Hz (0.009MHz-0.15MHz), 4 kHz (0.15MHz-30MHz), Scan time: auto. Phase NEUTRAL NEUTRAL NEUTRAL NEUTRAL NEUTRAL NEUTRAL NEUTRAL NEUTRAL NEUTRAL NEUTRAL NEUTRAL NEUTRAL Page 84 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 TR-4-E-010 Conducted Emission Test Result Test Site Test Date EUT Power Supply Condition Memo : DDT 1# Shield Room : 2022-08-16 : Bluetooth Headset : AC 120V/60Hz D:\2022 CE report date\Q22072825-2E JBL TOUR ONE2\FCC.EM6 Tested By : Bairong Model Number : TOUR ONE M2 Test Mode : Tx mode : TEMP:23.8°C, RH:62.0%, BP:101.2kPa LISN : : 2021 1# ENV216/LINE Data: 8 Item (Mark) 1 2 3 4 5 6 7 8 9 10 11 12 Freq. (MHz) 0.16 0.16 0.66 0.66 1.11 1.11 1.83 1.83 5.56 5.56 11.20 11.20 Read Level (dBV) 17.39 3.09 17.90 10.02 12.76 2.94 12.67 4.27 14.17 4.56 15.00 4.88 LISN Factor (dB) 9.66 9.66 9.52 9.52 9.59 9.59 9.51 9.51 9.54 9.54 9.58 9.58 Cable Loss (dB) 0.01 0.01 0.02 0.02 0.03 0.03 0.04 0.04 0.07 0.07 0.12 0.12 Pulse Limiter Factor (dB) 9.92 9.92 9.91 9.91 9.89 9.89 9.89 9.89 9.93 9.93 9.94 9.94 Result Level (dBV) 36.98 22.68 37.35 29.47 32.27 22.45 32.11 23.71 33.71 24.10 34.64 24.52 Limit Line (dBV) 65.30 55.30 56.00 46.00 56.00 46.00 56.00 46.00 60.00 50.00 60.00 50.00 Over Limit (dB) -28.32 -32.62 -18.65 -16.53 -23.73 -23.55 -23.89 -22.29 -26.29 -25.90 -25.36 -25.48 Detector QP Average QP Average QP Average QP Average QP Average QP Average Note: 1. Result Level = Read Level +LISN Factor + Pulse Limiter Factor + Cable loss. 2. If QP Result complies with AV limit, AV Result is deemed to comply with AV limit. 3. Test setup: RBW: 200 Hz (9 kHz--150 kHz), 9 kHz (150 kHz--30 MHz). 4. Step size: 80Hz (0.009MHz-0.15MHz), 4 kHz (0.15MHz-30MHz), Scan time: auto. Phase LINE LINE LINE LINE LINE LINE LINE LINE LINE LINE LINE LINE Page 85 of 86 Dongguan Dongdian Testing Service Co., Ltd. Report No.:DDT-R22072825-2E01 14. Antenna Requirements 14.1. Limit For intentional device, according to FCC 47 CFR Section 15.203, an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device. And according to FCC 47 CFR Section 15.247 (b), if transmitting antennas of directional gain greater than 6dBi are used, the power shall be reduced by the amount in dB that the directional gain of the antenna exceeds 6dBi. For intentional device, according to RSS-Gen issue 5 section 6.8. The applicant for equipment certification shall provide a list of all antenna types that may be used with the transmitter, where applicable (i.e. for transmitters with detachable antenna), indicating the maximum permissible antenna gain (in dBi) and the required impedance for each antenna. The test report shall demonstrate the compliance of the transmitter with the limit for maximum equivalent isotropically radiated power (e.i.r.p.) specified in the applicable RSS, when the transmitter is equipped with any antenna type, selected from this list. 14.2. Result The product is FPC antenna and that no antenna other than that furnished by the responsible party shall be used with the device, the maximum peak gain is 1.37 dBi. END OF REPORT Page 86 of 86
Related FCC IDs:
- APITOURONEM2 - Harman International Industries, Inc Bluetooth Headset [TOURONEM2] Acrobat Distiller 9.0.0 (Windows)