Exhibit 06 WinnForum FCCPart96 Test Report
twyna-to
Part 96 test report
Ericsson AB BKRY901537-1 Remote Radio Unit which supports LTE and NR TA8BKRY901537-1 TA8BKRY9015371 bkry901537 1
Ericsson AB BKRY901537-2 Remote Radio Unit which supports WCDMA, LTE , NBIoT, and NR TA8BKRY901537-2 TA8BKRY9015372 bkry901537 2
Ericsson AB BKRY901537-2 Remote Radio Unit which supports LTE and NR TA8BKRY901537-2 TA8BKRY9015372 bkry901537 2
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 76 Pages, 4.40MB
Document DEVICE REPORTGetApplicationAttachment.html?id=6583548Test Report As per FCC Part 96 SAS requirements (CBRS Test Plan) on the Ericsson Remote Radio Unit KRY 901 537/1 DOT 2256 B48B41B25B66 (3550-3700MHz) KRY 901 537/2 DOT 2266 B48B41B25B66 (35503700MHz) Issued by: TÜV SÜD Canada Inc. 1280 Teron Rd, Ottawa, ON K2K 2C1 Canada Steve McFarlane Test Personnel Scott Drysdale Report Reviewer Testing produced for Ericcson Canada See Appendix A for full client & EUT details. Testing Laboratory Certificate #2955.02 Page 1 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-002 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) Table of Contents Table of Contents ............................................................................................................................ 2 Report Scope ................................................................................................................................... 3 Summary ......................................................................................................................................... 4 Test Results Summary ................................................................................................................ 5 Notes, Justifications, or Deviations .......................................................................................... 14 Applicable Standards, Specifications and Methods...................................................................... 15 Document Revision Status............................................................................................................ 16 Definitions and Acronyms ............................................................................................................ 17 Testing Facility ............................................................................................................................. 18 Calibrations and Accreditations................................................................................................ 18 Testing Environmental Conditions and Dates .......................................................................... 19 Detailed Test Results Section ....................................................................................................... 20 Authorization transmit after it receives authorization from a SAS........................................... 21 Check the device registration and authorization with the SAS................................................. 29 Confirm that the device changes its operating power and/or channel in response to a command from the SAS and Confirm that the device correctly configures based on the different license classes. ...................................................................................................................................... 29 Confirm that the device transmits at a power level less than or equal to the maximum power level approved by the SAS........................................................................................................ 45 WINNF.FT.C.SCS.1 ..................................................................................................................... 55 WINNF.FT.C.SCS.2 ..................................................................................................................... 58 WINNF.FT.C.SCS.3 ..................................................................................................................... 61 WINNF.FT.C.SCS.4 ..................................................................................................................... 64 WINNF.FT.C.SCS.5 ..................................................................................................................... 66 Appendix A EUT & Client Provided Details ............................................................................ 72 Technical Description ............................................................................................................... 74 Appendix B EUT, Peripherals, and Test Setup Photos.............................................................. 75 Page 2 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) Report Scope This report addresses the EMC verification testing and test results of the KRY 901 537/2 DOT 2266 B48 (3550-3700MHz) herein referred to as EUT (Equipment Under Test). The EUT was tested for compliance against the following standards: FCC Part 96 SAS requirements (CBRS Test Plan) . Test procedures, results, justifications, and engineering considerations, if any, follow later in this report. For a more detailed list of the standards and the revision used, see the "Applicable Standards, Specifications and Methods" section of this report. This report does not imply product endorsement by any government, accreditation agency, or TÜV SÜD Canada Inc. Opinions or interpretations expressed in this report, if any, are outside the scope of TÜV SÜD Canada Inc accreditations. Any opinions expressed do not necessarily reflect the opinions of TÜV SÜD Canada Inc, unless otherwise stated. Page 3 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) Summary The results contained in this report relate only to the item(s) tested. Equipment Under Test (EUT) EUT passed all tests performed Tests conducted by KRY 901 537/2 DOT 2266 B48B41B25B666 (3550-3700MHz) Note: Non-Tested Variant Dot 2256 B48B41B25B666 KRY 901 537/1 (See Appendix A Technical Description for similarity description) Yes Steve McFarlane For testing dates, see 'Testing Environmental Conditions and Dates'. Page 4 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) Test Results Summary Section as per Working Document WINNF-TS-0122 Section CBS D Test Case ID Test Case Title D P 6.1.4.1. X -- WINNF.FT.C.R Multi-Step 1 EG.1 registration 6.1.4.1. -2 X WINNF.FT.D.R EG.2 Domain Proxy Multi-Step registration 6.1.4.1. X 3 -- WINNF.FT.C.R EG.3 Single-Step registration for Category A CBSD 6.1.4.1. -4 X WINNF.FT.D.R EG.4 Domain Proxy Single-Step registration for Cat A CBSD (Note: Mandatory for without CPI, if EUT will always have signed CPI asked for email waiver) RF Measurement Requirement Monitor for 60 seconds after REG message sent. No transmission during test. Monitor for 60 seconds after REG message sent. No transmission during test. Monitor for 60 seconds after REG message sent. No transmission during test. Monitor for 60 seconds after REG message sent. No transmission during test. Pass / Fail N/A P N/A N/A 6.1.4.1. X -- WINNF.FT.C.R Single-Step Monitor for 60 5 EG.5 registration for seconds after REG N/A CBSD with CPI message sent. No signed data transmission during test. 6.1.4.1. -- X WINNF.FT.D.R Domain Proxy Monitor for 60 6 EG.6 Single-Step seconds after REG P registration for message sent. No CBSD with CPI signed data transmission during test. 6.1.4.1. X X WINNF.FT.C.R Registration due to Test waits until 7 EG.7 change of an transmission starts, N/A then trigger an Page 5 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) installation installationParam parameter change. · Record time at which transmission stops. Time must be within 60 seconds of the installationPa ram change taking effect. 6.1.4.2. X -- WINNF.FT.C.R Missing Required Monitor for 60 1 EG.8 parameters seconds after REG N/A (responseCode 102) message sent. No transmission during test. 6.1.4.2. -- X WINNF.FT.D.R Domain Proxy Monitor for 60 2 EG.9 Missing Required seconds after REG P parameters message sent. No (responseCode 102) transmission during test. 6.1.4.2. X -- WINNF.FT.C.R Pending registration Monitor for 60 3 EG.10 (responseCode 200) seconds after REG N/A message sent. No transmission during test. 6.1.4.2. -- X WINNF.FT.D.R Domain Proxy Monitor for 60 4 EG.11 Pending registration seconds after REG P (responseCode 200) message sent. No transmission during test. 6.1.4.2. X -- WINNF.FT.C.R Invalid parameter Monitor for 60 5 EG.12 (responseCode 103) seconds after REG N/A message sent. No transmission during test. 6.1.4.2. -- X WINNF.FT.D.R Domain Proxy Monitor for 60 6 EG.13 Invalid parameters seconds after REG P (responseCode 103) message sent. No transmission during test. 6.1.4.2. X -- WINNF.FT.C.R Blacklisted CBSD Monitor for 60 7 EG.14 (responseCode 101) seconds after REG N/A message sent. No Page 6 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) transmission during test. 6.1.4.2. -- X WINNF.FT.D.R Domain Proxy Monitor for 60 8 EG.15 Blacklisted CBSD seconds after REG P (responseCode 101) message sent. No transmission during test. 6.1.4.2. X -- WINNF.FT.C.R Unsupported SAS Monitor for 60 9 EG.16 protocol version seconds after REG N/A (responseCode 100) message sent. No transmission during test. 6.1.4.2. -- X WINNF.FT.D.R Domain Proxy Monitor for 60 10 EG.17 Unsupported SAS seconds after REG P protocol version message sent. No responseCode 100) transmission during test. 6.1.4.2. X -- WINNF.FT.C.R Group Error Monitor for 60 11 EG.18 (responseCode 201) seconds after REG N/A message sent. No transmission during test. 6.1.4.2. -- X WINNF.FT.D.R Domain Proxy Monitor for 60 12 EG.19 Group Error seconds after REG P (responseCode 201) message sent. No transmission during test. 6.1.4.3. X X WINNF.FT.C.R Category A CBSD 1 EG.20 location update N/A 6.3.4.2. X X WINNF.FT.C.G Unsuccessful Grant Monitor for 60 1 RA.1 responseCode=400 seconds after REG P (TYPO FIXED (INTERFERENCE) message sent. No D TO C) transmission during test. 6.3.4.2. X X WINNF.FT.C.G Unsuccessful Grant Monitor for 60 2 RA.2 responseCode=401 seconds after REG P (GRANT_CONFLIC message sent. No T) transmission during test. 6.4.4.1. X -- WINNF.FT.C.H Heartbeat Success Monitor RF from 1 BT.1 Case (first Heartbeat start of test. Ensure N/A Response) that: · Transmission does not start until time of first Page 7 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) heartbeat response or after. · After transmission starts, meas ure that transmission is within the granted channel (frequencyLo w, freque ncyHigh) 6.4.4.1. -- X WINNF.FT.D.H Domain Proxy Monitor RF from 2 BT.2 Heartbeat Success start of test. Ensure P Case (first Heartbeat that: Response) · Transmission does not start until time of first heartbeat response or after. · After transmission starts, meas ure that transmission is within the granted channel (frequencyLo w, freque ncyHigh) 6.4.4.2. X X WINNF.FT.C.H Heartbeat Monitor RF 1 BT.3 responseCode=105 transmission. Ensur P (DEREGISTER) e that: · CBSD stops transmission within 60 seconds of the heartbeatRe sponse which contains Page 8 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) responseCod e = 105 6.4.4.2. X -- WINNF.FT.C.H Heartbeat 2 BT.4 responseCode=500 N/A (TERMINATED_G RANT) 6.4.4.2. X X WINNF.FT.C.H Heartbeat Monitor RF 3 BT.5 responseCode=501 transmission from P (SUSPENDED_GR start of test. Ensure ANT) in First there is no Heartbeat Response transmission during the test 6.4.4.2. X X WINNF.FT.C.H Heartbeat Monitor RF 4 BT.6 responseCode=501 transmission. Ensur P (SUSPENDED_GR e: ANT) in Subsequent · CBSD stops Heartbeat Response transmission within 60 seconds of heartbeatRe sponse which contains responseCod e=501 6.4.4.2. X X WINNF.FT.C.H Heartbeat Monitor RF 5 BT.7 responseCode=502 transmission. Ensur (UNSYNC_OP_PA e: P RAM) · CBSD stops transmission within 60 seconds of heartbeatRe sponse which contains responseCod e=502 6.4.4.2. -- X WINNF.FT.D.H Domain Proxy Monitor RF 6 BT.8 Heartbeat transmission. CBSD P responseCode=500 s will have different (TEMINATED_GR behavior: ANT) · CBSD1: will continue to transmit to Page 9 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 6.4.4.3. X 1 6.4.4.3. X 2 6.5.4.2. X 1 6.5.4.2. -2 end of test (this is not a pass/fail criteria, but check) · CBSD2: must stop transmission within 60 seconds of being sent heartbeatRe sponse with responseCod e = 500 X WINNF.FT.C.H Heartbeat Response Monitor RF from BT.9 Absent (First Heartbeat) start of test to 60 P seconds after last heartbeatResponse message was sent. CBSD should not transmit at any time during test X WINNF.FT.C.H Heartbeat Response Monitor RF BT.10 Absent (Subsequent transmission. Verify: P Heartbeat) · CBSD must stop transmission within transmitExpir eTime+60 seconds, where transmitExpir eTime is from last successful heartbeatRe sponse message -- WINNF.FT.C.M Registration No RF monitoring ES.1 Response contains N/A measReportConfig X WINNF.FT.D.M Domain Proxy ES.2 Registration No RF monitoring P Page 10 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) Response contains measReportConfig 6.5.4.2. X X WINNF.FT.C.M Grant Response No RF monitoring 3 ES.3 contains P measReportConfig 6.5.4.2. X -- WINNF.FT.C.M Heartbeat Response 4 ES.4 contains No RF monitoring N/A measReportConfig 6.5.4.2. -- X WINNF.FT.D.M Domain Proxy No RF monitoring 5 ES.5 Heartbeat Response P contains measReportConfig 6.6.4.1. X 1 -- WINNF.FT.C.R Successful LQ.1 Relinquishment Monitor RF transmission. Ensur N/A e: · CBSD stops transmission at any time prior to sending the relinquishme ntRequest message. 6.6.4.1. -- X WINNF.FT.D.R Domain Proxy Monitor RF 2 LQ.2 Successful transmission. Ensure P Relinquishment : · CBSD stops transmission at any time prior to sending the relinquishmentReque st message. 6.7.4.1. X 1 -- WINNF.FT.C.D Successful RG.1 Deregistration Monitor RF transmission. Ensur N/A e: · CBSD stops transmission at any time prior to sending the relinquishme ntRequest message or deregistrat ionRequest Page 11 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) message (whichever is sent first) 6.7.4.1. -- X WINNF.FT.D.D Domain Proxy Monitor RF 2 RG.2 Successful transmission. Ensure P Deregistration : · CBSD stops transmission at any time prior to sending the relinquishmentReque st message or deregistrationReques t message (whichever is sent first) 6.8.4.1. X X WINNF.FT.C.SC Successful TLS No RF transmission 1 S.1 connection between during test P UUT and SAS Test Check the tcpdump Harness for the TLS information 6.8.4.2. X X WINNF.FT.C.SC TLS failure due to No RF transmission 1 S.2 revoked certificate during test P Check the tcpdump for the TLS information 6.8.4.2. X X WINNF.FT.C.SC TLS failure due to No RF transmission 2 S.3 expired server during test P certificate Check the tcpdump for the TLS information 6.8.4.2. X X WINNF.FT.C.SC TLS failure when No RF transmission 3 S.4 SAS Test Harness during test P certificate is issue by Check the tcpdump unknown CA for the TLS information 6.8.4.2. X X WINNF.FT.C.SC TLS failure when No RF transmission 4 S.5 certificate at the SAS during test P Test Harness is Check the tcpdump corrupted for the TLS information 7.1.4.1. X X WINNF.PT.C.H UUT RF Transmit Power Spectral 1 BT Power Measurement Density test case. P Page 12 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) Assume we use 1 carrier bandwidth (say, 5 or 10 MHz), one frequency (say middle channel in band) for test. Measure at max transmit power, and reduce in steps of 3 dB to minimum declared transmit power. If the product as tested complies with the specification, the EUT is deemed to comply with the standard and is deemed a 'PASS' or `P' grade. If not 'FAIL' grade is issued. Where `N/A' is stated this means the test case is not applicable, and see Notes, Justifications or Deviations Section for details. Page 13 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) Notes, Justifications, or Deviations The following notes, justifications for tests not performed or deviations from the above listed specifications apply: Testing was performed at the client site, as per customer request A later revision of the standard may have been substituted in place of the previous dated referenced revision. The year of the specification used is listed under applicable standards. Using the later revision accomplishes the goal of ensuring compliance to the intent of the previous specification, while allowing the laboratory to incorporate the extensions and clarifications made available by a later revision. For the N/A test cases, the following justifications apply: a. EUT is a CBSD with Domain Proxy b. EUT supports the following Conditional functionality from WINNF-TS-0122V1.0.2 i. C1 Multi-step registration (WINNF.FT.D.REG.2) ii. C3 Single step registration containing CPI-signed data in the registration message (WINNF.FT.D.REG.6) iii. C4 RECEIVED_POWER_WITHOUT_GRANT measurement report (WINNF.FT.D.MES.2) iv. C5 RECEIVED_POWER_WITH_GRANT measurement report (WINNF.FT.D.MES.3, WINNF.FT.D.MES.5) c. Optional test cases were not performed The device does not use single-step registration (as defined in condition C2 in WINNF-TS-0122V1.0.2, Table 6-2), therefore test cases 6.1.4.1.4, and 6.1.4.3.1 are not applicable as per WINNFTS-0122-V1.0.2, Table 6-3 and therefore not required or performed. Note, where graph sweeps are incomplete, this was used to set the time stamp of when the events occurred. This can be accomplished by determining the time at which the graph was captured and subtracting the remaining time. For example if there was a 30 second sweep, and 9 out of 10 is complete, that means the end occurred at the 27 second market. If the time on the graph was 12:03:35, this means the graph started at 12:03:08. This allows us to co-ordinate graph with UTC in the logs. Logs are kept on file. Page 14 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) Applicable Standards, Specifications and Methods ANSI C63.4:2014 Methods of Measurement of Radio-Noise Emissions from LowVoltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz CFR47 FCC Part 96 Code of Federal Regulations Citizens Broadband Radio Service WINNF-TS-0122 Conformance and Performance Test Technical Specification; Version V1.0.2 CBSD/DP as Unit Under Test (UUT) 25 November 2020 Working Document ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories Page 15 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) Document Revision Status Revision 001: Revision 002: Revision 003: April 24, 2023 May 01, 2023 May 03, 2023 First Draft Second Draft Third Draft Page 16 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) Definitions and Acronyms The following definitions and acronyms are applicable in this report. See also ANSI C63.14. AE Auxiliary Equipment. A digital accessory that feeds data into or receives data from another device (host) that in turn, controls its operation. AM Amplitude Modulation Class A device A device that is marketed for use in a commercial, industrial or business environment. A 'Class A' device should not be marketed for use by the general public and the instructions for use accompanying the product shall contain the following text: Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. Class B device A device that is marketed for use in a residential environment and may also be used in a commercial, business or industrial environments. EMC Electro-Magnetic Compatibility. The ability of an equipment or system to function satisfactorily in its electromagnetic environment without introducing intolerable electromagnetic disturbances to anything in that environment. EMI Electro-Magnetic Immunity. The ability to maintain a specified performance when the equipment is subjected to disturbance (unwanted) signals of specified levels. Enclosure Port Physical boundary of equipment through which electromagnetic fields may radiate or impinge. EUT Equipment Under Test. A device or system being evaluated for compliance that is representative of a product to be marketed. LISN Line Impedance Stabilization Network NCR No Calibration Required NSA Normalized Site Attenuation RF Radio Frequency EMC Test Plan An EMC test plan established prior to testing. See 'Appendix A EUT & Client Provided Details'. Page 17 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) Testing Facility Testing for EMC on the EUT was performed at the client site, as per customer request. Calibrations and Accreditations TÜV SÜD Canada Inc is accredited to ISO/IEC 17025 by A2LA with Testing Certificate #2955.19. The laboratory's current scope of accreditation listing can be found as listed on the A2LA website. All measuring equipment is calibrated on an annual or bi-annual basis as listed for each respective test. Page 18 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) Testing Environmental Conditions and Dates Following environmental conditions were recorded in the facility during time of testing Date April 18-19, 2023 Test All Initials SM Temperature (ºC) 20-23 Humidity (%) 40-55 Pressure (kPa) 99.58 Page 19 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) Detailed Test Results Section Page 20 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) Authorization transmit after it receives authorization from a SAS. Section 6.1.4.1.2 DP Test Case ID X WINNF.FT.D.REG.2 Test Case Title Domain Proxy Multi-Step registration Pass / Fail P Page 21 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 6.1.4.1.6 X WINNF.FT.D.REG.6 Domain Proxy Single-Step registration for CBSD with CPI P signed data Page 22 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 6.1.4.2.2 X WINNF.FT.D.REG.9 Domain Proxy Missing Required parameters P (responseCode 102) Page 23 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 6.1.4.2.4 X WINNF.FT.D.REG.11 Domain Proxy Pending registration (responseCode P 200) Page 24 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 6.1.4.2.6 X WINNF.FT.D.REG.13 Domain Proxy Invalid parameters (responseCode 103) P Page 25 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 6.1.4.2.8 X WINNF.FT.D.REG.15 Domain Proxy Blacklisted CBSD (responseCode 101) P Page 26 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 6.1.4.2.10 X WINNF.FT.D.REG.17 Domain Proxy Unsupported SAS protocol version P responseCode 100) Page 27 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 6.1.4.2.12 X WINNF.FT.D.REG.19 Domain Proxy Group Error (responseCode 201) P Page 28 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) Check the device registration and authorization with the SAS, Confirm that the device changes its operating power and/or channel in response to a command from the SAS and Confirm that the device correctly configures based on the different license classes. 6.3.4.2.1 WINNF.FT.C.GRA.1 Unsuccessful Grant responseCode=400 (INTERFERENCE) Monitor for 60 seconds after REG message sent. No transmission P during test. Page 29 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 6.3.4.2.2 WINNF.FT.C.GRA.2 Unsuccessful Grant Monitor for 60 seconds after REG responseCode=401 message sent. No transmission P (GRANT_CONFLICT) during test. Page 30 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 6.4.4.1.2 WINNF.FT.D.HBT.2 Domain Proxy Heartbeat Monitor RF from start of Success Case (first test. Ensure that: P Heartbeat Response) · Transmission does not start until time of first heartbeat response or after. · After transmission starts, measure that transmission is within the granted channel (frequencyLow, frequenc yHigh) Page 31 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 6.4.4.2.1 WINNF.FT.C.HBT.3 Heartbeat responseCode=105 (DEREGISTER) Monitor RF transmission. Ensure that: P · CBSD stops transmission within 60 seconds of the heartbeatResponse which contains responseCode = 105 Page 32 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 6.4.4.2.3 WINNF.FT.C.HBT.5 Heartbeat Monitor RF transmission from start responseCode=501 of test. Ensure there is no p (SUSPENDED_GRANT) transmission during the test in First Heartbeat Response Page 33 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 6.4.4.2.4 WINNF.FT.C.HBT.6 Heartbeat Monitor RF transmission. Ensure: responseCode=501 · CBSD stops transmission p (SUSPENDED_GRANT) within 60 seconds of in Subsequent Heartbeat heartbeatResponse which Response contains responseCode=501 Page 34 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 6.4.4.2.5 WINNF.FT.C.HBT.7 Heartbeat Monitor RF transmission. Ensure: responseCode=502 (UNSYNC_OP_PARAM · CBSD stops transmission p ) within 60 seconds of heartbeatResponse which contains responseCode=502 Page 35 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 6.4.4.2. -- X WINNF.FT.D.H Domain Proxy Monitor RF 6 BT.8 Heartbeat transmission. CBSD P responseCode=500 s will have different (TEMINATED_GR behavior: ANT) · CBSD1: will continue to transmit to end of test (this is not a pass/fail criteria, but check) · CBSD2: must stop transmission within 60 seconds of being sent heartbeatRe sponse with responseCod e = 500 Page 36 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) Page 37 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 6.4.4.3.1 WINNF.FT.C.HBT.9 Heartbeat Response Monitor RF from start of test to 60 Absent (First Heartbeat) seconds after last P heartbeatResponse message was sent. CBSD should not transmit at any time during test Page 38 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 6.4.4.3.2 WINNF.FT.C.HBT.10 Heartbeat Response Absent (Subsequent Heartbeat) Monitor RF transmission. Verify: · CBSD must stop P transmission within transmitExpireTime+60 seconds, where transmitExpireTime is from last successful heartbeatResponse message Page 39 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 6.5.4.2.2 WINNF.FT.D.MES.2 Domain Proxy Registration Response No RF monitoring P contains measReportConfig Pass saw "measreportconfig" in logs Page 40 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 6.5.4.2.3 WINNF.FT.C.MES.3 Grant Response contains No RF monitoring measReportConfig P Pass saw "measreportconfig" in logs Page 41 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 6.5.4.2.5 WINNF.FT.D.MES.5 Domain Proxy Heartbeat No RF monitoring Response contains P measReportConfig Pass saw "measreportconfig" in logs Page 42 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 6.6.4.1.2 WINNF.FT.D.RLQ.2 Domain Proxy Successful Monitor RF transmission. Ensure: Relinquishment · CBSD stops transmission at P any time prior to sending the relinquishmentRequest message. Page 43 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 6.7.4.1.2 WINNF.FT.D.DRG.2 Domain Proxy Successful Monitor RF transmission. Ensure: Deregistration · CBSD stops transmission at P any time prior to sending the relinquishment Request message or deregistration Request message (whichever is sent first) Page 44 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) Confirm that the device transmits at a power level less than or equal to the maximum power level approved by the SAS. 7.1.4.1. X X WINNF.PT.C.H UUT RF Transmit Power Spectral 1 BT Power Measurement Density test case. P Assume we use 1 carrier bandwidth (say, 5 or 10 MHz), one frequency (say middle channel in band) for test. Measure at max transmit power, and reduce in steps of 3 dB to minimum declared transmit power. Page 45 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 3555 MHz Low power Page 46 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) PSD 3555 MHz High power Page 47 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) PSD 3635 MHz High power Page 48 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) PSD 3560 MHz Low power Page 49 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) PSD 3560 MHz High power Page 50 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) PSD 3640 MHz Low power Page 51 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) PSD 3640 MHz High power Page 52 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) PSD 3690 MHz Low power PSD Measurements Table LTE Raw Raw Freq 1MHz EIRP limit (target) dBm 3555 20 10 MHz 6.21 1 MHz -2.28 3555 17 3.29 -5.3 External Losses (dB) 14.3 14.3 Conducted dBm/MHz 12.02 9 Antenna gain dBi 4.9 4.9 3635 20 5.05 -3.5 14.3 10.8 4.9 3635 17 2.03 -6.5 14.3 7.8 4.9 3695 20 5.32 -3.3 14.3 11 4.9 3695 17 2.29 -6.4 14.3 7.9 4.9 Ports 2 2 2 2 2 2 Port gain (dB) 3.01 3.01 EIRP 1 MHz dBm/MHz 19.93 16.91 EIRP 10 MHz dBm 28.42 25.50 3.01 18.71 27.26 3.01 15.71 24.24 3.01 18.91 27.53 3.01 15.81 24.50 Margin dB 0.07 0.09 1.29 1.29 1.09 1.19 Page 53 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) PSD Measurements Table NR Raw Raw 1MHz EIRP limit Freq (target) dBm 3560 20 20 MHz 9.37 1 MHz -2.5 3560 17 6.3 -5.4 3640 20 3640 17 8.1 -3.8 5 -6.9 3690 20 3690 17 8.5 -3.2 5.4 -6.1 External Losses (dB) 14.3 14.3 Conducted dBm/MHz 11.8 8.9 Antenna gain dBi 4.9 4.9 14.3 10.5 4.9 14.3 7.4 4.9 14.3 11.1 4.9 14.3 8.2 4.9 Ports 2 2 2 2 2 2 Port gain (dB) 3.01 3.01 EIRP 1 MHz dBm/MHz 19.71 16.81 EIRP 20 MHz dBm 31.58 28.51 3.01 18.41 30.31 3.01 15.31 27.21 3.01 19.01 30.71 3.01 16.11 27.61 Margin dB 0.29 0.19 1.59 1.69 0.99 0.89 Page 54 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) WINNF.FT.C.SCS.1 Packet Capture Sequence WINNF Security Test Case Analysis WINNF test requirements: WINNF test requirements from WINNF-TS-0122-V1.0.2 CBRS CBSD Test Specification: Analysis of WINNF Test Requirements 1. From Client Hello: TLS version = TLS 1.2 Page 55 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 2. Cipher suite list from Client Hello is from WINNF approved list: Cipher Suites (43 suites) Cipher Suite: TLS_ECDHE_ECDSA_WITH_AES_256_GCM_SHA384 (0xc02c) Cipher Suite: TLS_ECDHE_ECDSA_WITH_AES_128_GCM_SHA256 (0xc02b) Cipher Suite: TLS_ECDHE_RSA_WITH_AES_256_GCM_SHA384 (0xc030) Cipher Suite: TLS_ECDHE_RSA_WITH_AES_128_GCM_SHA256 (0xc02f) Cipher Suite: TLS_DHE_RSA_WITH_AES_256_GCM_SHA384 (0x009f) Cipher Suite: TLS_DHE_DSS_WITH_AES_256_GCM_SHA384 (0x00a3) Cipher Suite: TLS_DHE_RSA_WITH_AES_128_GCM_SHA256 (0x009e) Cipher Suite: TLS_DHE_DSS_WITH_AES_128_GCM_SHA256 (0x00a2) Cipher Suite: TLS_ECDHE_ECDSA_WITH_AES_256_CBC_SHA384 (0xc024) Cipher Suite: TLS_ECDHE_RSA_WITH_AES_256_CBC_SHA384 (0xc028) Cipher Suite: TLS_ECDHE_ECDSA_WITH_AES_128_CBC_SHA256 (0xc023) Cipher Suite: TLS_ECDHE_RSA_WITH_AES_128_CBC_SHA256 (0xc027) Cipher Suite: TLS_DHE_RSA_WITH_AES_256_CBC_SHA256 (0x006b) Cipher Suite: TLS_DHE_DSS_WITH_AES_256_CBC_SHA256 (0x006a) Cipher Suite: TLS_DHE_RSA_WITH_AES_128_CBC_SHA256 (0x0067) Cipher Suite: TLS_DHE_DSS_WITH_AES_128_CBC_SHA256 (0x0040) Cipher Suite: TLS_ECDH_ECDSA_WITH_AES_256_GCM_SHA384 (0xc02e) Cipher Suite: TLS_ECDH_RSA_WITH_AES_256_GCM_SHA384 (0xc032) Cipher Suite: TLS_ECDH_ECDSA_WITH_AES_128_GCM_SHA256 (0xc02d) Cipher Suite: TLS_ECDH_RSA_WITH_AES_128_GCM_SHA256 (0xc031) Cipher Suite: TLS_ECDH_ECDSA_WITH_AES_256_CBC_SHA384 (0xc026) Cipher Suite: TLS_ECDH_RSA_WITH_AES_256_CBC_SHA384 (0xc02a) Cipher Suite: TLS_ECDH_ECDSA_WITH_AES_128_CBC_SHA256 (0xc025) Cipher Suite: TLS_ECDH_RSA_WITH_AES_128_CBC_SHA256 (0xc029) Cipher Suite: TLS_ECDHE_ECDSA_WITH_AES_256_CBC_SHA (0xc00a) Cipher Suite: TLS_ECDHE_RSA_WITH_AES_256_CBC_SHA (0xc014) Cipher Suite: TLS_ECDHE_ECDSA_WITH_AES_128_CBC_SHA (0xc009) Cipher Suite: TLS_ECDHE_RSA_WITH_AES_128_CBC_SHA (0xc013) Cipher Suite: TLS_DHE_RSA_WITH_AES_256_CBC_SHA (0x0039) Cipher Suite: TLS_DHE_DSS_WITH_AES_256_CBC_SHA (0x0038) Cipher Suite: TLS_DHE_RSA_WITH_AES_128_CBC_SHA (0x0033) Cipher Suite: TLS_DHE_DSS_WITH_AES_128_CBC_SHA (0x0032) Cipher Suite: TLS_ECDH_ECDSA_WITH_AES_256_CBC_SHA (0xc005) Cipher Suite: TLS_ECDH_RSA_WITH_AES_256_CBC_SHA (0xc00f) Cipher Suite: TLS_ECDH_ECDSA_WITH_AES_128_CBC_SHA (0xc004) Cipher Suite: TLS_ECDH_RSA_WITH_AES_128_CBC_SHA (0xc00e) Cipher Suite: TLS_RSA_WITH_AES_256_GCM_SHA384 (0x009d) Cipher Suite: TLS_RSA_WITH_AES_128_GCM_SHA256 (0x009c) Page 56 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) Cipher Suite: TLS_RSA_WITH_AES_256_CBC_SHA256 (0x003d) Cipher Suite: TLS_RSA_WITH_AES_128_CBC_SHA256 (0x003c) Cipher Suite: TLS_RSA_WITH_AES_256_CBC_SHA (0x0035) Cipher Suite: TLS_RSA_WITH_AES_128_CBC_SHA (0x002f) Cipher Suite: TLS_EMPTY_RENEGOTIATION_INFO_SCSV (0x00ff) 3. Cipher suite chosen (from Server Hello): TLS_RSA_WITH_AES_256_GCM_SHA384 (0x009d) 4. The Registration request message arrived at the Test Harness, authentication was completed. Page 57 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) WINNF.FT.C.SCS.2 Packet Capture Sequence Requirements: WINNF test requirements from WINNF-TS-0122-V1.0.2 CBRS CBSD Test Specification: Analysis of WINNF Test Requirements 1. From Client Hello can read: TLS version = TLS 1.2 Page 58 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 2. From Client Hello, cipher suite list is from WINNF approved list: TLS_RSA_WITH_AES_128_GCM_SHA25 TLS_ECDHE_ECDSA_WITH_AES_128_GCM_SHA256 TLS_ECDHE_RSA_WITH_AES_128_GCM_SHA256 3. From Server Hello, cipher suite chosen: TLS_RSA_WITH_AES_128_GCM_SHA256 4. Read OSCP Request/Response to/from server: 5. Authentication exchange ends with TLS Alert message (i.e. Authentication fails): Page 59 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 6. Registration request message is not received at Test Harness (authentication fails) Page 60 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) WINNF.FT.C.SCS.3 Packet Capture Sequence WINNF Test Requirements: WINNF test requirements from WINNF-TS-0122-V1.0.2 CBRS CBSD Test Specification: Analysis of WINNF Test Requirements 1. From Client Hello can read: TLS version = TLS 1.2 2. From Client Hello, cipher suite list is from WINNF approved list: Cipher Suites Page 61 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 3. From Server Hello, cipher suite chosen: TLS_RSA_WITH_AES_256_GCM_SHA384 (0x009d) Page 62 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 4. Authentication exchange ends with TLS Alert message (i.e. authentication fails): 5. Registration request message is not received at Test Harness (Authentication fails) Page 63 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) WINNF.FT.C.SCS.4 Packet Capture Sequence WINNF Test Requirements: WINNF test requirements from WINNF-TS-0122-V1.0.2 CBRS CBSD Test Specification: Analysis of WINNF Test Requirements 1. From Client Hello can read: TLS version = TLS 1.2 2. From Client Hello, cipher suite list is from WINNF approved list: Page 64 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 3. From Server Hello, cipher suite chosen: TLS_RSA_WITH_AES_256_GCM_SHA384 (0x009d) Page 65 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 4. Authentication exchange ends with TLS Alert message (i.e. authentication fails): 5. Registration request message is not received at Test Harness (authentication fails) WINNF.FT.C.SCS.5 Packet Capture Sequence Page 66 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) WINNF Test Requirements: WINNF test requirements from WINNF-TS-0122-V1.0.2 CBRS CBSD Test Specification: Analysis of WINNF Test Requirements 1. From Client Hello can read: TLS version = TLS 1.2 2. From Client Hello, cipher suite list is from WINNF approved list: Page 67 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 3. From Server Hello, cipher suite chosen: TLS_RSA_WITH_AES_256_GCM_SHA384 (0x009d) Page 68 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 4. Authentication exchange ends with TLS Alert message (i.e. authentication fails): 5. Registration request message is not received at Test Harness (Authentication fails) Page 69 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) 1. Registration request message is not received at Test Harness (authentication fails) Page 70 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) Test Equipment Instrument Manufacturer Power Supply Signal Analyzer Attenuator Switching Control Unit RF Switch Unit Power Supply Xantrex Agilent Pasternack Hewlett Packard Burnsco Leader Type No. XKW 60-50 MXA PE7004-10 11713A RARFSW 4x1 730-3D Serial No E00109863 SSG013930 N/S 3748A060876 001 9801135 Calibration Period (months) Calibration Due O/P Mon - 12 months 2024-04-26 O/P Mon O/P Mon O/P Mon O/P Mon - Page 71 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) Appendix A EUT & Client Provided Details Page 72 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) General EUT Description Manufacturer Address Product Name Product Number Serial Number(s) RAN Software Version Domain Proxy Software Version Hardware Version Test Specification/Issue/Date Ericsson Torshamnsgatan 23 Kista SE-16480 Stockholm Sweden Dot 2266 B48B41B25B66 Dot 2256 B48B41B25B66 (Non-Tested Variant. See Technical Description for the similarity description) KRY 901 537/2 KRY 901 537/1 (Non-Tested Variant. See Technical Description for the similarity description) TD3W388604 CXP9024418/15-R73B05 ERICdomainproxyservice_CXP9035414 2.63.4 R1B FCC CFR 47 Part 96: 2017 Page 73 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) Technical Description The Equipment Under Test (EUT) Dot 2266 B48B41B25B66 (KRY 901 537/2) are Remote Radio Units forming part of the Ericsson Radio Base Station (RBS) equipment.The Dot provides radio access for mobile and fixed devices and is intended for the indoor environment.The radio operates over 8 Transmit ports in MRO (NR+LTE); Single,Multi-Carrier,and MIMO transmission with a maximum rated RF output up to 0.4W per port over an operational temperature of 5deg C to +40 deg C. The unit is designed to be ceiling or wall mounted. The 2256 and 2266 radios are identical except that Dot 2256 has internal antennas and Dot 2266 has external RF ports. The Equipment Under Test (EUT) is shown in the photograph below. A full technical description can be found in the Manufacturer's documentation. EUT Configuration Please see Appendix B for close up pictures of the unit as configured during testing · Cables and earthing when applicable were connected as per manufacturer's specification. Domain Proxy Software Version: ERICdomainproxyservice_CXP9035414 2.63.4 Page 74 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) Appendix B EUT, Peripherals, and Test Setup Photos Page 75 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc. Client Product Standard(s) Ericsson KRY 901 537/1 DOT 2256 B48B41B25B66 (35503700MHz) & KRY 901 537/2 DOT 2266 B48B41B25B66 (3550-3700MHz) FCC Part 96 SAS requirements (CBRS Test Plan) Test setup Page 76 of 76 Report Issued: 5/3/2023 Report File #: 7169012176A-CBRS-003 © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc.
Related FCC IDs:
- TA8BKRY901537-1 - Ericsson AB Remote Radio Unit which supports WCDMA, LTE , NBIoT, and NR [BKRY901537-1]
- TA8BKRY901537-2 - Ericsson AB Remote Radio Unit which supports WCDMA, LTE , NBIoT, and NR [BKRY901537-2] PDFCreator 3.2.0.11758