ANTENNA TEST REPORT
For
Antenna
Model Number: LJF02-21043010-R0A

Report Number : WT238000955

Test Laboratory : Shenzhen Academy of Metrology and Quality

Inspection

Site Location

: NETC Building, No.4 Tongfa Rd., Xili, Nanshan,

Shenzhen, China

Tel

: 0086-755-86928965

Fax

: 0086-755-86009898-31396

Web

: www.smq.com.cn

Report No.: WT238000955

Page 1/12

Applicant
Address
Manufacturer
Address EUT Description MODEL No

TEST REPORT DECLARATION

: Shenzhen Jiancheng Yunshi Technology Co., Ltd

:

A2101, Building 9, Zone 2, No. 3609 Baishi Road, N anshan District, Shenzhen

: Shenzhen Jiancheng Yunshi Technology Co., Ltd

:

A2101, Building 9, Zone 2, No. 3609 Baishi Road, N anshan District, Shenzhen

: Antenna

: LJF02-21043010-R0A

Test Standards: IEEE Std 149-1979

The EUT described above is tested by Shenzhen Academy of Metrology and Quality Inspection EMC Laboratory to determine the maximum emissions from the EUT and ensure the EUT to be compliance with the immunity requirements of the EUT. Shenzhen Academy of Metrology and Quality Inspection EMC Laboratory is assumed full responsibility for the accuracy of the test results.
The test report is valid for above tested sample only and shall not be reproduced in part without written approval of the laboratory.

Project Engineer: Checked by: Approved by:

(Zhou Li ) (Wan Xiao Jing )
(Lin Yi Xiang )

Date: Date: Date:

May. 16, 2023 May. 16, 2023 May. 16, 2023

Report No.: WT238000955

Page 2/12

TABLE OF CONTENTS
TEST REPORT DECLARATION ........................................................................................................2 1. TEST RESULTS SUMMARY ...................................................................................................4 2. GENERAL INFORMATION......................................................................................................5
2.1. Report information..........................................................................................................5 2.2. Laboratory Accreditation and Relationship to Customer .........................................5 3. GENERAL INFORMATION......................................................................................................6 4. TEST PROCEDURE ..................................................................................................................6 5. SUMMATION TEST REPORT .................................................................................................7 5.1. Equipment Under Test DescRiption ............................................................................7 5.2. Test Setup .......................................................................................................................7 6. TEST EQUIPMENT USED .......................................................................................................8 7. TEST DATA ................................................................................................................................8 7.1. TEST RESULTS.............................................................................................................8

Report No.: WT238000955

Page 3/12

1. TEST RESULTS SUMMARY
Table 1 Test Results Summary Frequency Band (MHz)
2402-2480 5175-5275 5725-5825 Remark: "N/A" means "Not applicable."

Gain -1.68 1.47 4.24

Report No.: WT238000955

Page 4/12

2. GENERAL INFORMATION

2.1. Report information
This report is not a certificate of quality; it only applies to the sample of the specific product/equipment given at the time of its testing. The results are not used to indicate or imply that they are application to the similar items. In addition, such results must not be used to indicate or imply that SMQ approves recommends or endorses the manufacture, supplier or use of such product/equipment, or that SMQ in any way guarantees the later performance of the product/equipment.
The sample/s mentioned in this report is/are supplied by Applicant, SMQ therefore assumes no responsibility for the accuracy of information on the brand name, model number, origin of manufacture or any information supplied.
Additional copies of the report are available to the Applicant at an additional fee. No third part can obtain a copy of this report through SMQ, unless the applicant has authorized SMQ in writing to do so.
The lab will not be liable for any loss or damage resulting for false, inaccurate, inappropriate or incomplete product information provided by the applicant/manufacturer.
2.2. Laboratory Accreditation and Relationship to Customer
The testing report were performed by the Shenzhen Academy of Metrology and quality Inspection EMC Laboratory (Guangdong EMC compliance testing center), in their facilities located at NETC Building, No.4 Tongfa Rd., Xili, Nanshan, Shenzhen, China. At the time of testing, Laboratory is accredited by the following organizations:

China National Accreditation Service for Conformity Assessment (CNAS) accredits the Laboratory for conformance to FCC standards, EMC international standards and EN standards. The Registration Number is CNAS L0579.

The Laboratory is Accredited Testing Laboratory of FCC with Designation number CN1165 and Site registration number 582918.

The Laboratory is registered to perform emission tests with Innovation, Science and Economic Development (ISED), and the registration number is 11177A.

The Laboratory is registered to perform emission tests with VCCI, and the registration number are C-20048, G20076, R-20077, R-20078 and T-20047.

The Laboratory is Accredited Testing Laboratory of American Association for Laboratory Accreditation (A2LA) and certificate number is 3292.01.

Report No.: WT238000955

Page 5/12

3. GENERAL INFORMATION
Over the Air Measurements (Active) are performed in a Satimo SG-24. The SG-24 has 23 probe antennas mounted with equal spacing on a circular arch. Electronic switching of the probe antennas provides outstanding measurement speed. The geometry of the setup, with only a Styrofoam column within 1.6 meters of the EUT, ensures minimum interference and low ripple on the measured radiation patterns.
Figure 1­ SG-24. The DUT is placed on top of the pedestal, in the center of the system.
4. TEST PROCEDURE
The gain of the antenna was measured in the anechoic chamber Satimo SG24. The chamber provides less than ­30 dB reflectivity from 400 MHz through 6 GHz. The chamber size is:8m*5m*5m. The measurement results are calibrated using a dipole antenna. The antenna gain and efficiency are measured with AUT placed in the chamber.

Report No.: WT238000955

Page 6/12

5. SUMMATION TEST REPORT
5.1. Equipment Under Test DescRiption Date of Measurements: Device Manufacturer: Antenna Type Temperature Relative Humidity
5.2. Test Setup

May. 12, 2023 Shenzhen Jiancheng Yunshi
Technology Co., Ltd LOOP
22~24  40~50 %

Report No.: WT238000955

Page 7/12

6. TEST EQUIPMENT USED
Table 2 Test Equipment

No. SB9011/01
--

Equipment Network analyzer
Passive Measurement

Manufacturer Agilent
SATIMO

Model No. E5071C
1.1.4

LAST CALIB 2023.04.24
--

Period 1 Year
--

7. TEST DATA
7.1. TEST RESULTS
Frequency 2402 2407 2412 2417 2422 2427 2432 2437 2442 2447 2452 2457 2462 2467 2472 2480 5180 5185 5190 5195 5200 5205 5210 5215 5220 5225 5230 5235 5240 5245 5250 5255 5260 5265
Report No.: WT238000955

Gain -1.83 -1.86 -2.14 -2.26 -2.14 -2.08 -1.86 -1.79 -1.79 -1.68 -1.88 -2.18 -2.65 -2.89 -2.56 -2.44 1.47 1.30 1.27 1.19 1.31 1.20 1.17 1.01 0.95 0.88 0.92 0.94 0.98 0.75 0.52 0.22 0.05 0.02

Page 8/12

5270

0.11

5275

0.12

5725

2.87

5730

2.97

5735

3.03

5740

3.08

5745

3.18

5750

3.25

5755

3.27

5760

3.35

5765

3.35

5770

3.37

5775

3.45

5780

3.46

5785

3.49

5790

3.64

5795

3.65

5800

3.73

5805

3.84

5810

3.99

5815

4.08

5820

4.17

5825

4.24

Peak Gain

Report No.: WT238000955

Page 9/12

X-Z Plane

Y-Z Plane

Report No.: WT238000955

X-Y Plane

Page 10/12

2402 MHz

5180 MHz
Report No.: WT238000955

Page 11/12

5800 MHz ----------------------END----------------------

Report No.: WT238000955

Page 12/12

