03 FCC Test Report DSC

Panasonic Corporation of North America 932IK3600F RKE TXE ACJ932IK3600F ACJ932IK3600F 932ik3600f

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 16 Pages, 402.37KB

Document DEVICE REPORTGetApplicationAttachment.html?id=4154791
Test report No. Page Issued date FCC ID

: 12541448H-R1 : 1 of 18 : January 31, 2019 : ACJ932IK3600F

RADIO TEST REPORT

Test Report No. : 12541448H-R1

Applicant

: Panasonic Corporation of North America

Type of Equipment

: RKE TXE

Model No.

: IK3600F

FCC ID

: ACJ932IK3600F

Test regulation

: FCC Part 15 Subpart C: 2018

Test Result

: Complied (Refer to SECTION 3.2)

1. This test report shall not be reproduced in full or partial, without the written approval of UL Japan, Inc. 2. The results in this report apply only to the sample tested. 3. This sample tested is in compliance with the above regulation. 4. The test results in this report are traceable to the national or international standards. 5. This test report covers Radio technical requirements. It does not cover administrative issues such as
Manual or non-Radio test related Requirements. (if applicable) 6. The all test items in this test report are conducted by UL Japan, Inc. Ise EMC Lab. 7. This test report must not be used by the customer to claim product certification, approval, or
endorsement by NVLAP, NIST, or any agency of the Federal Government. 8. The information provided from the customer for this report is identified in SECTION 1. 9. This report is a revised version of 12541448H. 12541448H is replaced with this report.

Date of test:

December 5, 2018

Representative test engineer:

Hiroyuki Furutaka Engineer
Consumer Technology Division

Approved by:

Shinichi Miyazono Engineer
Consumer Technology Division

This laboratory is accredited by the NVLAP LAB CODE 200572-0, U.S.A. The tests reported herein have been performed in accordance with its terms of accreditation. *As for the range of Accreditation in NVLAP, you may refer to the WEB address, http://japan.ul.com/resources/emc_accredited/

NVLAP LAB CODE: 200572-0
The testing in which "Non-accreditation" is displayed is outside the accreditation scopes in UL Japan. There is no testing item of "Non-accreditation".

UL Japan, Inc. Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124

13-EM-F0429

Test report No. Page Issued date FCC ID

: 12541448H-R1 : 2 of 18 : January 31, 2019 : ACJ932IK3600F

REVISION HISTORY

Original Test Report No.: 12541448H

Revision
(Original) 1
1

Test report No. 12541448H 12541448H-R1 12541448H-R1

Date January 28, 2019

Page revised
-

January 31, 2019 P.8

January 31, 2019 P.18

Contents
-
Deletion of "Duty Cycle" from Test Item in Clause 4.1 Correction of axis name in Worst case position

UL Japan, Inc. Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124

Test report No. Page Issued date FCC ID

: 12541448H-R1 : 3 of 18 : January 31, 2019 : ACJ932IK3600F

CONTENTS

PAGE

SECTION 1: Customer information.......................................................................................................4 SECTION 2: Equipment under test (E.U.T.).........................................................................................4 SECTION 3: Test specification, procedures & results..........................................................................5 SECTION 4: Operation of E.U.T. during testing ..................................................................................8 SECTION 5: Radiated emission (Electric Field Strength of Fundamental and Spurious Emission)9 SECTION 6: Automatically deactivate ................................................................................................11 SECTION 7: -20 dB and 99 % Occupied Bandwidth .........................................................................11 APPENDIX 1: Test data ........................................................................................................................12
Automatically deactivate...................................................................................................................12 Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission) .....................13 -20dB and 99% Occupied Bandwidth...............................................................................................15 APPENDIX 2: Test instruments ...........................................................................................................16 APPENDIX 3: Photographs of test setup .............................................................................................17 Radiated emission .............................................................................................................................17 Worst case position ...........................................................................................................................18

UL Japan, Inc. Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124

Test report No. Page Issued date FCC ID

: 12541448H-R1 : 4 of 18 : January 31, 2019 : ACJ932IK3600F

SECTION 1: Customer information

Company Name Address Telephone Number Facsimile Number Contact Person

: Panasonic Corporation of North America*1) : Two Riverfront Plaza, 9th Floor Newark, NJ 07102-5490 : +1-201-348-7760 : +1-201-348-7760 : Ben Botros

The information provided from the customer is as follows; - Applicant, Type of Equipment, Model No. on the cover and other relevant pages - SECTION 1: Customer information - SECTION 2: Equipment under test (E.U.T.) - SECTION 4: Operation of E.U.T. during testing * The laboratory is exempted from liability of any test results affected from the information in SECTION 2 and 4.

*1) Panasonic Corporation of North America designates Panasonic Automotive Systems Asia Pacific Co.,Ltd as manufacturer of the product (RKE TXE).

SECTION 2: Equipment under test (E.U.T.)

2.1

Identification of E.U.T.

Type of Equipment Model No. Serial No. Rating Receipt Date of Sample (Information from test lab.) Country of Mass-production Condition of EUT
Modification of EUT

: RKE TXE : IK3600F : Refer to Section 4, Clause 4.2 : DC 3.0 V : December 4, 2018
: Thailand : Production prototype
(Not for Sale: This sample is equivalent to mass-produced items.) : No Modification by the test lab

2.2

Product Description

Model: IK3600F (referred to as the EUT in this report) is a RKE TXE.

Radio Specification

Radio Type Frequency of Operation Modulation Antenna type Clock frequency (Maximum)

: Transmitter : 433.92 MHz : FSK : Copper printing monopole antenna : 27.6 MHz

UL Japan, Inc. Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124

Test report No. Page Issued date FCC ID

: 12541448H-R1 : 5 of 18 : January 31, 2019 : ACJ932IK3600F

SECTION 3: Test specification, procedures & results

3.1

Test Specification

Test Specification

: FCC Part 15 Subpart C FCC Part 15 final revised on March 12, 2018 and effective April 11, 2018

Title

: FCC 47CFR Part15 Radio Frequency Device Subpart C Intentional Radiators

Section 15.231 Periodic operation in the band 40.66-40.70 MHz and above 70 MHz.

3.2

Procedures and results

Item Conducted emission

Test Procedure

Specification

FCC: ANSI C63.10:2013 FCC: Section 15.207

6 Standard test methods

IC: RSS-Gen 8.8

IC: RSS-Gen 8.8

Worst margin Results

N/A *1)

N/A

Remarks -

Automatically Deactivate
Electric Field Strength of Fundamental Emission
Electric Field Strength of Spurious Emission
-20dB Bandwidth

FCC: ANSI C63.10:2013 FCC: Section 6 Standard test methods 15.231(a)(1)

IC: -

IC: RSS-210 A1.1

FCC: ANSI C63.10:2013 FCC: Section 15.231(b) 6 Standard test methods

IC: RSS-Gen 6.12

IC: RSS-210 A1.2

FCC: ANSI C63.10:2013 FCC: Section 15.205

6 Standard test methods

Section 15.209

Section 15.231(b)

IC: RSS-Gen 6.13

IC: RSS-210 A1.2, 4.4

RSS-Gen 8.9

FCC: ANSI C63.10:2013 FCC: Section 15.231(c)

6 Standard test methods

IC: -

IC: Reference data

N/A

Complied a)

1.0 dB 433.920 MHz Horizontal PK with Duty factor
1.3 dB 3905.280 MHz Vertical PK with Duty factor

Complied# b)
Complied# c)

N/A

Complied d)

Radiated Radiated Radiated Radiated

Note: UL Japan, Inc.'s EMI Work Procedures No. 13-EM-W0420 and 13-EM-W0422. *1) The test is not applicable since the EUT does not have AC Mains.

a) Refer to APPENDIX 1 (data of Automatically Deactivate)

b) Refer to APPENDIX 1 (data of Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission))

c) Refer to APPENDIX 1 (data of Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission))

d) Refer to APPENDIX 1 (data of -20dB and 99% Occupied Bandwidth)

Symbols:

Complied

The data of this test item has enough margin, more than the measurement uncertainty.

Complied#

The data of this test item meets the limits unless the measurement uncertainty is taken into consideration.

FCC 15.31 (e) This test was performed with the New Battery (DC 3.0 V) during the tests. Therefore, the EUT complies with the requirement.

FCC Part 15.203 Antenna requirement It is impossible for end users to replace the antenna, because the antenna is mounted inside of the EUT. Therefore, the equipment complies with the antenna requirement of Section 15.203.

UL Japan, Inc. Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124

3.3

Addition to standard

Test report No. Page Issued date FCC ID

: 12541448H-R1 : 6 of 18 : January 31, 2019 : ACJ932IK3600F

Item

Test Procedure

Specification

Worst margin Results

99 % Occupied Bandwidth

IC: RSS-Gen 6.7

IC: RSS-210 A1.3

N/A

Complied

Other than above, no addition, exclusion nor deviation has been made from the standard.

Remarks Radiated

3.4

Uncertainty

There is no applicable rule of uncertainty in this applied standard. Therefore, the following results are derived depending on whether or not laboratory uncertainty is applied.

The following uncertainties have been calculated to provide a confidence level of 95 % using a coverage factor k = 2.

Polarity
Horizontal Vertical

Radiated emission (Below 1 GHz)

(3 m*)(+/-)

(10 m*)(+/-)

30 MHz to 200 MHz 200 MHz to 1000 MHz 30 MHz to 200 MHz 200 MHz to 1000 MHz

4.8 dB

5.2 dB

4.8 dB

5.0 dB

5.0 dB

6.3 dB

4.9 dB

5.0 dB

Radiated emission (Above 1 GHz)

(3 m*)(+/-)

(1 m*)(+/-)

1 GHz to 6 GHz 6 GHz to 18 GHz 10 GHz to 26.5 GHz 26.5 GHz to 40 GHz

5.0 dB

5.3 dB

5.8 dB

5.8 dB

* Measurement distance

(10 m*)(+/-) 1 GHz to 18 GHz
5.2 dB

Automatically Deactivate 0.10 %

Bandwidth 0.96 %

UL Japan, Inc. Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124

Test report No. Page Issued date FCC ID

: 12541448H-R1 : 7 of 18 : January 31, 2019 : ACJ932IK3600F

3.5

Test Location

UL Japan, Inc. Ise EMC Lab.

4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN

Telephone: +81 596 24 8999, Facsimile: +81 596 24 8124

NVLAP Lab. code: 200572-0 / FCC Test Firm Registration Number: 199967

Test site

IC Registration Width x Depth x

Number

Height (m)

Size of reference ground plane (m) / horizontal conducting plane

Other rooms

Maximum measuremen t distance

No.1 semi-anechoic chamber

2973C-1

19.2 x 11.2 x 7.7 7.0 x 6.0

No.1 Power source room

10 m

No.2 semi-anechoic chamber

2973C-2

7.5 x 5.8 x 5.2

4.0 x 4.0

-

3 m

No.3 semi-anechoic chamber

2973C-3

12.0 x 8.5 x 5.9 6.8 x 5.75

No.3 Preparation room

3 m

No.3 shielded room -

4.0 x 6.0 x 2.7

N/A

-

-

No.4 semi-anechoic chamber

2973C-4

12.0 x 8.5 x 5.9 6.8 x 5.75

No.4 Preparation room

3 m

No.4 shielded room -

4.0 x 6.0 x 2.7

N/A

-

-

No.5 semi-anechoic chamber

-

6.0 x 6.0 x 3.9

6.0 x 6.0

-

-

No.6 shielded room -

4.0 x 4.5 x 2.7

4.0 x 4.5

-

-

No.6 measurement room

-

4.75 x 5.4 x 3.0 4.75 x 4.15

-

-

No.7 shielded room -

4.7 x 7.5 x 2.7

4.7 x 7.5

-

-

No.8 measurement room

-

3.1 x 5.0 x 2.7

3.1 x 5.0

-

-

No.9 measurement room

-

8.8 x 4.6 x 2.8

2.4 x 2.4

-

-

No.11 measurement room

-

6.2 x 4.7 x 3.0

4.8 x 4.6

-

-

* Size of vertical conducting plane (for Conducted Emission test) : 2.0 m x 2.0 m for No.1, No.2, No.3, and No.4 semi-anechoic chambers and No.3 and No.4 shielded rooms.

3.6

Test data, Test instruments, and Test set up

Refer to APPENDIX.

UL Japan, Inc. Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124

Test report No. Page Issued date FCC ID

: 12541448H-R1 : 8 of 18 : January 31, 2019 : ACJ932IK3600F

SECTION 4: Operation of E.U.T. during testing

4.1

Operating Mode(s)

Test Item*

Mode

Automatically Deactivate

Normal use mode

Electric Field Strength of Fundamental Emission

Transmitting mode (Tx) *1)

Electric Field Strength of Spurious Emission

-20 dB & 99 % Occupied Bandwidth

* The system was configured in typical fashion (as a user would normally use it) for testing.

*1) End users cannot change the settings of the output power of the product.

4.2

Configuration and peripherals

A

* Cabling and setup(s) were taken into consideration and test data was taken under worse case conditions.

Description of EUT No. Item
A RKE TXE

Model number IK3600F

*1) Used for Normal use mode *2) Used for Transmitting mode

Serial number Manufacturer

No.33 *1) No.18 *2)

Panasonic Automotive Systems Asia Pacific Co.,Ltd

Remarks EUT

UL Japan, Inc. Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124

Test report No. Page Issued date FCC ID

: 12541448H-R1 : 9 of 18 : January 31, 2019 : ACJ932IK3600F

SECTION 5: Radiated emission (Electric Field Strength of Fundamental and Spurious Emission)

Test Procedure and conditions
[For below 30 MHz] The noise level was checked by moving a search-coil (Loop Antenna) close to the EUT.
[For 30 MHz to 1 GHz] EUT was placed on a urethane platform of nominal size, 0.5 m by 1.0 m, raised 0.8 m above the conducting ground plane. The Radiated Electric Field Strength has been measured in a Semi Anechoic Chamber with a ground plane.

[For above 1 GHz] EUT was placed on a urethane platform of nominal size, 0.5 m by 0.5 m, raised 1.5 m above the conducting ground plane. The Radiated Electric Field Strength has been measured in a Semi Anechoic Chamber with absorbent materials lined on a ground plane.
The measuring antenna height was varied between 1 and 4 m and EUT was rotated a full revolution in order to obtain the maximum value of the electric field strength. The measurements were performed for both vertical and horizontal antenna polarization. The radiated emission measurements were made with the following detector function of the test receiver / spectrum analyzer.

Test Antennas are used as below;

Frequency

Below 30 MHz

Antenna Type

Loop

30 MHz to 200 MHz Biconical

200 MHz to 1 GHz Logperiodic

Above 1 GHz Horn

Detector Type
IF Bandwidth

From 9 kHz to 90 kHz and From 110 kHz
to 150 kHz Peak
200 Hz

From 90 kHz to 110 kHz
Peak
200 Hz

From 150 kHz to 490 kHz
Peak
9.0 kHz

From 490 kHz to 30 MHz
Peak
9.0 kHz

From 30 MHz to 1 GHz
Peak and Peak with Duty factor 120 kHz

Above 1 GHz
Peak and Peak with Duty factor PK: S/A: RBW 1 MHz,
VBW: 3 MHz

UL Japan, Inc. Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124

[Test Setup] Below 1 GHz

Test report No. Page Issued date FCC ID

: 12541448H-R1 : 10 of 18 : January 31, 2019 : ACJ932IK3600F

Test Distance: 3 m

1 GHz - 10 GHz

Distance Factor: 20 x log (4.0 m / 3.0 m) = 2.5 dB * Test Distance: (3 + Test Volume /2) - r = 4.0 m
Test Volume : 2.0 m (Test Volume has been calibrated based on CISPR 16-1-4.)
r = 0.0 m
* The test was performed with r = 0.0 m since EUT is small and it was the rather conservative condition.

- The carrier level (or, noise levels) was (or were) measured at each position of all three axes X, Y and Z, and the position that has the maximum noise was determined. Noise levels of all the frequencies were measured at the position.
*The result is rounded off to the second decimal place, so some differences might be observed.

Measurement range Test data Test result

: 9 kHz - 4.4 GHz : APPENDIX : Pass

UL Japan, Inc. Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124

Test report No. Page Issued date FCC ID

SECTION 6: Automatically deactivate

Test Procedure

The measurement was performed with Electric field strength using a spectrum analyzer.

Test data Test result

: APPENDIX : Pass

: 12541448H-R1 : 11 of 18 : January 31, 2019 : ACJ932IK3600F

SECTION 7: -20 dB and 99 % Occupied Bandwidth

Test Procedure

The test was measured with a spectrum analyzer using a test fixture.

Test

Span

RBW

20 dB Bandwidth
99 % Occupied Bandwidth

150 kHz
Enough width to display emission skirts

1.5 kHz
1 to 5 % of OBW

Peak hold was applied as Worst-case measurement.

VBW
5.1 kHz
Three times of RBW

Sweep
Auto Auto

Test data Test result

: APPENDIX : Pass

Detector Trace

Peak

Max Hold

Peak

Max Hold

Instrument used
Spectrum Analyzer Spectrum Analyzer

UL Japan, Inc. Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124

Test report No. Page Issued date FCC ID

: 12541448H-R1 : 12 of 18 : January 31, 2019 : ACJ932IK3600F

APPENDIX 1: Test data

Automatically deactivate

Report No. Test place Semi Anechoic Chamber Date Temperature / Humidity Engineer Mode

12541448H Ise EMC Lab. No.4 December 5, 2018 23 deg. C / 48 % RH Ryota Yamanaka Normal use mode

Time of Transmitting
[sec]
0.1583

Limit
[sec] 5.00

Result Pass

UL Japan, Inc. Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124

Test report No. Page Issued date FCC ID

: 12541448H-R1 : 13 of 18 : January 31, 2019 : ACJ932IK3600F

Radiated Emission (Electric Field Strength of Fundamental and Spurious Emission)

Report No. Test place Semi Anechoic Chamber Date Temperature / Humidity Engineer
Mode

12541448H Ise EMC Lab. No.4 December 5, 2018 (Day) 22 deg. C / 51 % RH Hiroyuki Furutaka (Above 1GHz) Tx 433.92 MHz

No.4 December 5, 2018 (Night) 23 deg. C / 53 % RH Ryota Yamanaka (Below 1GHz)

PK Frequency

Detector

[MHz] 433.920 PK 867.840 PK
1301.760 PK 1735.680 PK 2169.600 PK 2603.520 PK 3037.440 PK 3471.360 PK 3905.280 PK 4339.200 PK

Reading

[dBuV]

Hor

Ver

84.6 84.4

38.0 30.3

43.8 44.0

49.5 48.0

44.1 44.0

47.9 46.5

46.0 46.2

45.1 44.9

47.0 47.2

45.5 45.0

Ant Factor [dB/m]
16.4 22.0 25.4 25.3 27.5 28.2 28.5 29.0 29.7 30.4

Loss
[dB] 10.8 13.0 6.2 5.8 5.8 6.0 6.1 6.3 6.4 6.7

Gain
[dB] 32.0 31.4 33.1 32.0 31.4 31.2 31.1 30.9 30.7 30.7

Duty Factor [dB]
-

Result

Limit

[dBuV/m]

Hor

Ver [dBuV/m]

79.8 79.6 100.8

41.6 33.9 80.8

42.3 42.5 73.9

48.6 47.1 80.8

46.0 45.9 80.8

50.9 49.5 80.8

49.5 49.7 80.8

49.5 49.3 80.8

52.4 52.6 73.9

51.9 51.4 73.9

Margin

Remark

[dB]

Inside or Outside

Hor

Ver of Restricted Bands

21.0 21.2 Carrier

39.2 46.9 Outside

31.6 31.4 Inside

32.2 33.7 Outside

34.8 34.9 Outside

29.9 31.3 Outside

31.3 31.1 Outside

31.3 31.5 Outside

21.5 21.3 Inside

22.0 22.5 Inside

PK with Duty factor Frequency Detector
[MHz] 433.920 PK 867.840 PK
1301.760 PK 1735.680 PK 2169.600 PK 2603.520 PK 3037.440 PK 3471.360 PK 3905.280 PK 4339.200 PK

Reading

[dBuV]

Hor

Ver

84.6 84.4

38.0 30.3

43.8 44.0

49.5 48.0

44.1 44.0

47.9 46.5

46.0 46.2

45.1 44.9

47.0 47.2

45.5 45.0

Ant Factor [dB/m]
16.4 22.0 25.4 25.3 27.5 28.2 28.5 29.0 29.7 30.4

Loss
[dB] 10.8 13.0 6.2 5.8 5.8 6.0 6.1 6.3 6.4 6.7

Gain
[dB] 32.0 31.4 33.1 32.0 31.4 31.2 31.1 30.9 30.7 30.7

Duty Factor [dB]
0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

Result

Limit

[dBuV/m]

Hor

Ver [dBuV/m]

79.8 79.6 80.8

41.6 33.9 60.8

42.3 42.5 53.9

48.6 47.1 60.8

46.0 45.9 60.8

50.9 49.5 60.8

49.5 49.7 60.8

49.5 49.3 60.8

52.4 52.6 53.9

51.9 51.4 53.9

Margin

Remark

[dB]

Hor

Ver

1.0

1.2 Carrier

19.2 26.9 Outside

11.6 11.4 Inside

12.2 13.7 Outside

14.8 14.9 Outside

9.9 11.3 Outside

11.3 11.1 Outside

11.3 11.5 Outside

1.5

1.3 Inside

2.0

2.5 Inside

Sample calculation: Result of PK = Reading + Ant Factor + Loss {Cable + Attenuator + Filter (above 1GHz) +Distance factor (above 1 GHz)} - Gain (Amplifier) Result of PK with Duty factor = Reading + Ant Factor + Loss {Cable + Attenuator + Filter (above 1 GHz) +Distance factor (above 1 GHz)} - Gain (Amplifier) + Duty factor (Refer to Duty factor data sheet)
For above 1GHz : Distance Factor: 20 x log (4.0 m/3.0 m) = 2.50 dB *Other frequency noises omitted in this report were not seen or had enough margin (more than 20dB).
Since the peak emission result satisfied the average limit, duty factor was omitted. Although Duty of this product was 100% or less, the result of AV (PK with Duty factor) was calculated by applying Duty 100% as worst.

UL Japan, Inc. Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124

Test report No. Page Issued date FCC ID

: 12541448H-R1 : 14 of 18 : January 31, 2019 : ACJ932IK3600F

Radiated Spurious Emission (Plot data, Worst case)

Report No. Test place Semi Anechoic Chamber Date Temperature / Humidity Engineer
Mode

12541448H Ise EMC Lab. No.4 December 5, 2018 (Day) 22 deg. C / 51 % RH Hiroyuki Furutaka (Above 1GHz) Tx 433.92 MHz

No.4 December 5, 2018 (Night) 23 deg. C / 53 % RH Ryota Yamanaka (Below 1GHz)

Field strength [dBuV/m]

110 100 90 80 70 60 50 40 30 20 10
10

Horizontal

100 Peak

1000 Frequency [MHz]

Average

Average Limit

10000

Field strength [dBuV/m]

110 100 90 80 70 60 50 40 30 20 10
10

Vertical

100 Peak

1000 Frequency [MHz]

Average

Average Limit

10000

*These plots data contains sufficient number to show the trend of characteristic features for EUT.

UL Japan, Inc. Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124

Test report No. Page Issued date FCC ID

-20dB and 99% Occupied Bandwidth

Report No. Test place Semi Anechoic Chamber Date Temperature / Humidity Engineer Mode

12541448H Ise EMC Lab. No.4 December 5, 2018 22 deg. C / 51 % RH Hiroyuki Furutaka Tx 433.92 MHz

: 12541448H-R1 : 15 of 18 : January 31, 2019 : ACJ932IK3600F

Bandwidth Limit : Fundamental Frequency 433.92 MHz x 0.25% = 1084.80 kHz * The above limit was calculated from more stringent nominal frequency.

-20dB Bandwidth [kHz] 32.962

Bandwidth Limit [kHz]
1084.80

Result Pass

99% Occupied Bandwidth [kHz]
32.3656

Bandwidth Limit [kHz]
1084.80

Result Pass

UL Japan, Inc. Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124

Test report No. Page Issued date FCC ID

: 12541448H-R1 : 16 of 18 : January 31, 2019 : ACJ932IK3600F

APPENDIX 2: Test instruments

Test Instruments

Test LIMS Description

Manufacturer Model

Serial

Last

Calibration Cal

item ID

Calibration Due Date

Int

Date

RE 141545 DIGITAL

HIOKI

3805

51201148

1/9/2018

1/31/2019

12

HiTESTER

RE 141508 Horn Antenna

Schwarzbeck

BBHA9120D 9120D-557

6/8/2018

6/30/2019

12

1-18GHz

RE 141506 Horn Antenna

Schwarzbeck

BBHA9170

BBHA9170307

6/8/2018

6/30/2019

12

15-40GHz

RE 142227 Measure

KOMELON

KMC-36

-

-

-

-

RE 141581 MicroWave System AGILENT

83017A

650

10/4/2018

10/31/2019

12

Amplifier

RE 141412 Microwave Cable

Junkosha

MWX221

1305S002R(1m) / 6/14/2018

6/30/2019

12

1405S146(5m)

RE 142011 AC4_Semi Anechoic TDK

Semi Anechoic DA-10005

6/28/2018

6/30/2020

24

Chamber(NSA)

Chamber 3m

RE 141562 Thermo-Hygrometer CUSTOM

CTH-180

1501

1/24/2018

1/31/2019

12

RE 141901 Spectrum Analyzer AGILENT

E4440A

MY48250080

10/4/2018

10/31/2019

12

RE 141297 High Pass

TOKYO KEIKI TF219CD1

1001

1/18/2018

1/31/2019

12

Filter(1.1-10GHz)

RE 141152 EMI measurement

TSJ

TEPTO-DV

-

-

-

-

program

RE 142017 AC4_Semi Anechoic TDK

Semi Anechoic DA-10005

4/7/2018

4/30/2019

12

Chamber(SVSWR)

Chamber 3m

RE 141583 Pre Amplifier

SONOMA

310

260833

2/27/2018

2/28/2019

12

INSTRUMENT

RE 141267 Logperiodic

Schwarzbeck

VUSLP9111B 911B-192

6/1/2018

6/30/2019

12

Antenna(200-1000M

Hz)

RE 141951 EMI Test Receiver

Rohde &

ESR26

101408

1/30/2018

1/31/2019

12

Schwarz

RE 141397 Coaxial Cable

UL Japan

-

-

6/13/2018

6/30/2019

12

RE 148898 Attenuator

KEYSIGHT

8491A

MY52462282

10/3/2018

10/31/2019

12

RE 141425 Biconical Antenna

Schwarzbeck

BBA9106

1302

6/1/2018

6/30/2019

12

RE 142645 Loop Antenna

UL Japan

-

-

-

-

-

*Hyphens for Last Calibration Date, Calibration Due Date and Cal Int (month) are instruments that Calibration is not required (e.g. software), or instruments checked in advance before use.

The expiration date of the calibration is the end of the expired month. All equipment is calibrated with valid calibrations. Each measurement data is traceable to the national or international standards.

As for some calibrations performed after the tested dates, those test equipment have been controlled by means of an unbroken chains of calibrations.

Test item: RE: Radiated emission, 99 % Occupied Bandwidth, -20 dB bandwidth, and Automatically deactivate tests

UL Japan, Inc. Ise EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN Telephone : +81 596 24 8999 Facsimile : +81 596 24 8124

