CUSTOMIZE EVERY INSTALL TO SATISFY
EVERY HOMEOWNER
PRO1 Technologies
Exclusively For Professionals
At PRO1 we pride ourselves in being the "Friend of the Trade." Every feature in our thermostats is designed to make an installer's life easier. We believe that algorithms in staging restrict the technician's ability to customize installs and troubleshoot complications. At PRO1 we control all our cycles and staging solely by time and temperature. | www.pro1iaq.com

Customize Installs Like a PRO
Simple. Affordable. Professional.
No two installs are alike. Each building, heating and cooling system and homeowner is unique. At PRO1, we give you the tools to customize each install to tailor to the needs of your customers.

°

The Swing Settings, Satisfy Setpoint, and Staging

Delay give you the ability to maximize Comfort,

F

E ciency, and Equipment Longevity better than any

other thermostat manufacturer on the planet.

Balancing these three variables based on the priority

of the homeowner is the best way to control any

HVAC system. The chart below illustrates how these

features are used to accommodate their needs.

Variables
Comfort Comfort is very individualized and a key variable used in balancing an HVAC system to satisfy a homeowner. Adding comfort to a home is the primary purpose of a heating and cooling system. However, maximizing comfort can compromise the e ciency of the system.
E ciency With the average household spending more than $2000 a year on energy bills, balancing this variable is important to many people. Our features allow you to customize dependent upon the type of system, equipment abilities, energy sources, and desired results.
Equipment Longevity Cycling the system on and o frequently reduces the lifespan of the equipment. Increasing length of run times will increase the amount of time before your system needs to be replaced.

Swing Setting 0.2º - 2.0º
Satisfy Setpoint ON or OFF
Staging Delay OFF, 5, 10, 15, 30, 45, 60, 90

Comfort Maximized by SMALL
swings. Maximized when ON.
Maximized when OFF.

E ciency
Maximized by LARGE swings.
Maximized when OFF.
Maximized by LONG delay.

Equipment Longevity
Maximized by LARGE swings.
Maximized when ON.
Maximized by LONG delay.

Swing Setting
All PRO1 thermostats have separate, adjustable swing settings for heat and cool. They are adjustable from 0.2º to 2º in increments of 0.1º. The temperature swings below and above the setpoint.

Swing Setting - In all Models

This feature allows the user to choose how close the system

73º

Heat O

will stay within the setpoint temperature. A small swing will maximize comfort while a large swing maximizes e ciency.

72º

Set Point Temp

The example on the right illustrates a two stage system in heat with a 72° setpoint temperature and a 1° swing. The rst

71º

1st Stage On

stage energizes at 71°. If needed, auxiliary will energize at 70°. The system will not shut o until 1º above setpoint at 73°.

70º

1st Stage On

Featuring
Set At Set At

T855iSH
Universal - WIFI Residential/Light Commercial Up to 5 Heat, 3 Cool Heat Pump Up to 2 Heat, 2 Cool Conventional 7 Day or Non-Programmable Hardwire Only
Exclusively for HVAC professionals.
Compatible with every PRO1 subbase.
T751
Universal Residential
Up to 4 Heat, 2 Cool Heat Pump Up to 2 Heat, 2 Cool Conventional Non-Programmable Battery or Hardwire
Exclusively for HVAC professionals.
Compatible with any 3H/2C Heat Pump or 1H/1C Conventional PRO1 subbase.
T721i
Heat Pump/Conventional - WIFI Residential
2 Heat, 1 Cool Heat Pump 1 Heat, 1 Cool Conventional 7 Day, 5/1/1, or Non-Programmable Through App Hardwire Only
Exclusively for HVAC professionals.
Compatible with any 2H/1C Heat Pump or 1H/1C Conventional PRO1 subbase.

Satisfy Setpoint
Models T621-2, T625-2, T715, T721, T721i, T725, T751, T755, T755S, T855, T855SH, T855iSH
Satisfy Setpoint allows the thermostats to keep additional stages of heat or cool energized until the setpoint is satis ed. This will increase equipment longevity and maximize the use of all stages until the desired temperature is reached and prevents the system from drooping.
The examples below illustrate a two-stage system in heat mode. If a thermostats setpoint is 72° and there is a 1° swing setting, when the auxiliary is energized both stages will remain on until the temperature reaches 73°. If the system uses gas auxiliary the heat pump will not remain on. See graph below.

73° 72° 71° 70° 69°
O
73° 72° 71° 70° 69°
O

Two Stage System with Satisfy Setpoint OFF

System O

1st Stage Heat

Auxiliary Heat

1st

Auxiliary

1st

O

Two Stage System with Satisfy Setpoint ON

System O

1st Stage Heat

Auxiliary Heat

1st

Auxiliary

1st

O

Staging Delay
Models T621-2, T715, T721, T721i, T725, T755, T755S, T855, T855SH, T855iSH
Staging Delay is an optional and adjustable feature which allows you to set a delay to occur when there is a call for additional stages of heat or cool. The delay can be set from OFF to 5, 10, 15, 30, 45, 60 or 90.
This feature delays the second and third stage of heat and cool needed. This allows the previous stage extra time to satisfy setpoint. The technician can choose between a 0, 5, 10, 15, 30, 45, 60, and 90 minute delay. The examples below illustrate a two-stage system in heat mode with a 20 minute staging delay. In moderate temperatures the system is able to recuperate without engaging auxiliary. In extreme temperatures the auxiliary is still needed and kicks in after the 20 minute staging delay is over.

System O

1st Stage Heat

Auxiliary Heat

73° 72° 71° 70° 69°

0

5

1st

10

15

20 1st

25

30

Auxiliary

1st

O

Two Stage System with Staging Delay OFF

73° 72° 71° 70° 69°
0

System O

1st Stage Heat

Auxiliary Heat

5

10

15

20 1st

25

30

1st Stage

Two Stage System with Staging Delay ON

73° 72° 71° 70° 69°
0

System O

1st Stage Heat

Auxiliary Heat

5

10

15

20 1st

25

30

1st Stage

Auxiliary

Two Stage System with Staging Delay ON