RF exposure evaluation

Hangzhou Bublue Sciences and Technologies Ltd. C20H Robotic Pool Cleaner 2BLJI-C20H 2BLJIC20H c20h

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 11 Pages, 2.21MB

Document DEVICE REPORTGetApplicationAttachment.html?id=8363107
Page 1 of 11

FCC ID: 2BLJI-C20H

Report No.: LCSA04155033EC

RF Exposure Evaluation For
Hangzhou Bublue Sciences and Technologies Ltd. Robotic Pool Cleaner Test Model: C20H

Prepared for Address

: Hangzhou Bublue Sciences and Technologies Ltd. : ROOM 202, BUILDING 2, BLOCK A, NO. 365 WUZHOU ROAD,
LINPING DISTRICT, HANGZHOU, 311100, ZHEJIANG, CHINA

Prepared by Address
Tel Fax Web Mail

: Shenzhen LCS Compliance Testing Laboratory Ltd. : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei,
Shajing Street, Baoan District, Shenzhen, 518000, China : (+86)755-82591330 : (+86)755-82591332 : www.LCS-cert.com : [email protected]

Date of receipt of test sample Number of tested samples Sample No. Serial number Date of Test Date of Report

: April 29, 2025 : 2 : A250429070-1, A250429070-2 : Prototype : April 29, 2025 ~ May 26, 2025 : May 27, 2025

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 2 of 11

FCC ID: 2BLJI-C20H

Report No.: LCSA04155033EC

RF Exposure Evaluation
Report Reference No. ................. : LCSA04155033EC Date of Issue ................................... : May 27, 2025
Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd.
Address ........................................... : 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China
Testing Location Procedure ............ : Full application of Harmonised standards  Partial application of Harmonised standards  Other standard testing method 
Applicant's Name.......................... : Hangzhou Bublue Sciences and Technologies Ltd. Address ........................................... : ROOM 202, BUILDING 2, BLOCK A, NO. 365 WUZHOU ROAD,
LINPING DISTRICT, HANGZHOU, 311100, ZHEJIANG, CHINA
Test Specification
Standard.......................................... : FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06 FCC CFR 47 part1 1.1310 FCC CFR 47 part2 2.1091
Test Report Form No. ................... : TRF-4-E-214 A/0 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd. Master TRF ..................................... : Dated 2011-03 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. EUT Description. ........................... : Robotic Pool Cleaner
Trade Mark...................................... : N/A Test Model ...................................... : C20H Ratings ............................................ : Power Box's Input Voltage: 100Vac-240Vac; 50/60Hz
Power Box's Rated Output Current: Max. 5A Power Box's Rated Output Charging Current: Max. 2.5A Power Box's Rated Output Voltage: 28V
Result ........................................... : PASS

Compiled by:

Supervised by:

Approved by:

Nadia Zhou/ Administrator

Jack Liu/ Technique principal

Gavin Liang/ Manager

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 3 of 11

FCC ID: 2BLJI-C20H

Report No.: LCSA04155033EC

RF Exposure Evaluation

Test Report No. :

LCSA04155033EC

May 27, 2025 Date of issue

Test Model............................... : C20H

EUT......................................... : Robotic Pool Cleaner

Applicant............................... Address..................................
Telephone............................... Fax..........................................

: Hangzhou Bublue Sciences and Technologies Ltd. : ROOM 202, BUILDING 2, BLOCK A, NO. 365 WUZHOU ROAD,
LINPING DISTRICT, HANGZHOU, 311100, ZHEJIANG, CHINA : / : / :

Manufacturer........................ Address...................................
Telephone............................... Fax..........................................

: Hangzhou Bublue Sciences and Technologies Ltd. : ROOM 202, BUILDING 2, BLOCK A, NO. 365 WUZHOU ROAD,
LINPING DISTRICT, HANGZHOU, 311100, ZHEJIANG, CHINA : / : / :

Factory................................... Address...................................
Telephone............................... Fax..........................................

: Hangzhou Bublue Sciences and Technologies Ltd. : ROOM 202, BUILDING 2, BLOCK A, NO. 365 WUZHOU ROAD,
LINPING DISTRICT, HANGZHOU, 311100, ZHEJIANG, CHINA : / : /

Test Result

PASS

The test report merely corresponds to the test sample.

It is not permitted to copy extracts of these test result without the written permission of the test laboratory.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 4 of 11

FCC ID: 2BLJI-C20H

Report No.: LCSA04155033EC

Report Version 000

Revision History

Issue Date May 27, 2025

Revision Content Initial Issue

Revised By --

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 5 of 11

FCC ID: 2BLJI-C20H

Report No.: LCSA04155033EC

Description

TABLE OF CONTENTS

Page

1. PRODUCT INFORMATION ................................................................................................................................... 6 2. EVALUATION METHOD ........................................................................................................................................ 7 3. LIMIT.......................................................................................................................................................................... 7 4. MPE CALCULATION METHOD ........................................................................................................................... 8 5. ANTENNA INFORMATION ................................................................................................................................... 8 6. CONDUCTED POWER........................................................................................................................................... 8 7. MANUFACTURING TOLERANCE ....................................................................................................................... 9 8. MEASUREMENT RESULTS ............................................................................................................................... 10 9. CONCLUSION ....................................................................................................................................................... 11 10. DESCRIPTION OF TEST FACILITY ................................................................................................................ 11 11. MEASUREMENT UNCERTAINTY ................................................................................................................... 11

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 6 of 11

FCC ID: 2BLJI-C20H

Report No.: LCSA04155033EC

1. Product Information

EUT

: Robotic Pool Cleaner

Test Model

: C20H

Ratings

: Power Box's Input Voltage: 100Vac-240Vac; 50/60Hz

Power Box's Rated Output Current: Max. 5A Power Box's Rated Output Charging Current: Max. 2.5A

Power Box's Rated Output Voltage: 28V

Hardware Version

: /

Software Version

: /

Bluetooth

Frequency Range

: 2402MHz~2480MHz

Channel Number

: 40 channels for Bluetooth V5.0 (DTS)

Channel Spacing

: 2MHz for Bluetooth V5.0 (DTS)

Modulation Type

: GFSK for Bluetooth V5.0 (DTS)

Bluetooth Version

: V5.0

Antenna Description : PCB Antenna, 3.37dBi (Max.)

WIFI(2.4G Band)

Frequency Range

: 2412MHz~2462MHz

Channel Spacing

: 5MHz

Channel Number

: 11 Channels for 20MHz bandwidth (2412~2462MHz)

7 Channels for 40MHz bandwidth (2422~2452MHz)

Modulation Type

: IEEE 802.11b: DSSS (CCK, DQPSK, DBPSK) IEEE 802.11g: OFDM (64QAM, 16QAM, QPSK, BPSK)

IEEE 802.11n: OFDM (64QAM, 16QAM, QPSK, BPSK)

Antenna Description : PCB Antenna, 3.37dBi (Max.)

Exposure category

: General population/uncontrolled environment

EUT Type

: Production Unit

Device Type

: Mobile Devices

Note: For a more detailed antenna description, please refer to the antenna specifications or the anten na report provided by the customer.

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 7 of 11

FCC ID: 2BLJI-C20H

Report No.: LCSA04155033EC

2. Evaluation Method
Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the Commission's guidelines. In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile device whereby a distance of 0.2m normally can be maintained between the user and the device, and below RF Permissible Exposure limit shall comply with. In accordance with KDB447498D01 for Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modelled or measured field strengths or power density, is  1.0. The MPE ratio of each antenna is determined at the minimum test separation distance required by the operating configurations and exposure conditions of the host device, according to the ratio of field strengths or power density to MPE limit, at the test frequency. Either the maximum peak or spatially averaged results from measurements or numerical simulations may be used to determine the MPE ratios. Spatial averaging does not apply when MPE is estimated using simple calculations based on far-field plane-wave equivalent conditions. The antenna installation and operating requirements for the host device must meet the minimum test separation distances required by all antennas, in both standalone and simultaneous transmission operations, to satisfy compliance.

3. Limit

3. 1 Refer Evaluation Method

ANSI C95.1­2019: IEEE Standard for Safety Levels with Respect to Human Exposure to Electric, Magnetic, and Electromagnetic Fields, 0 Hz to 300 GHz FCC KDB publication 447498 D01 General 1 RF Exposure Guidance v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies. FCC CFR 47 part1 1.1310: Radiofrequency radiation exposure limits. FCC CFR 47 part2 2.1091: Radiofrequency radiation exposure evaluation: mobile devices.

3. 2 Limit

Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure

Frequency

Electric Field Magnetic Field Power Density Averaging Time

Range(MHz) Strength(V/m) Strength(A/m)

(mW/cm²)

(minute)

Limits for Occupational/Controlled Exposure

0.3 ­ 3.0

614

1.63

(100) *

6

3.0 ­ 30

1842/f

4.89/f

(900/f2)*

6

30 ­ 300

61.4

0.163

1.0

6

300 ­ 1500

/

/

f/300

6

1500 ­ 100,000

/

/

5

6

Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure

Frequency

Electric Field Magnetic Field Power Density Averaging Time

Range(MHz) Strength(V/m) Strength(A/m)

(mW/cm²)

(minute)

Limits for Occupational/Uncontrolled Exposure

0.3 ­ 3.0

614

1.63

(100) *

30

3.0 ­ 30

824/f

2.19/f

(180/f2)*

30

30 ­ 300

27.5

0.073

0.2

30

300 ­ 1500

/

/

f/1500

30

1500 ­ 100,000

/

/

1.0

30

F=frequency in MHz *=Plane-wave equivalent power density

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 8 of 11

FCC ID: 2BLJI-C20H

Report No.: LCSA04155033EC

4. MPE Calculation Method
Predication of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01
S=PG/4R²
Where: S=power density P=power input to antenna G=power gain of the antenna in the direction of interest relative to an isotropic radiator R=distance to the center of radiation of the antenna

5. Antenna Information
EUT can only use antennas certificated as follows provided by manufacturer;

Internal/External Identification

Antenna type and antenna number

Maximum antenna Operate frequency band
gain

Internal

PCB Antenna

2400-2500MHz

3.37dBi

Notes
BT/WIFI Antenna

6. Conducted Power

Mode GFSK

Channel
00 19 39

Mode GFSK

Channel
00 19 39

[BLE 1M] Frequency (MHz) 2402 2440 2480
[BLE 2M] Frequency (MHz) 2402 2440 2480

Peak Conducted Output Power (dBm) -0.99 1.51 0.47
Peak Conducted Output Power (dBm) -1.10 1.38 0.33

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 9 of 11

FCC ID: 2BLJI-C20H

Report No.: LCSA04155033EC

Mode
IEEE 802.11b
IEEE 802.11g
IEEE 802.11n HT20
IEEE 802.11n HT40

Channel
1 6 11 1 6 11 1 6 11 3 6 9

[2.4G WLAN]
Frequency (MHz)
2412 2437 2462 2412 2437 2462 2412 2437 2462 2422 2437 2452

Peak Conducted Output Power (dBm) 14.03 13.61 13.16 14.47 13.96 13.67 13.91 13.41 13.10 12.59 11.54 12.36

7. Manufacturing Tolerance

Channel Target (dBm) Tolerance ±(dB)
Channel Target (dBm) Tolerance ±(dB)

[BLE 1M] GFSK(Peak)

Channel 00

Channel 19

0

1.0

1.0

1.0

[BLE 2M] GFSK(Peak)

Channel 00

Channel 19

-1.0

1.0

1.0

1.0

Channel 39 0 1.0
Channel 39 0 1.0

Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 10 of 11

FCC ID: 2BLJI-C20H

Report No.: LCSA04155033EC

Channel Target (dBm) Tolerance ±(dB)
Channel Target (dBm) Tolerance ±(dB)
Channel Target (dBm) Tolerance ±(dB)
Channel Target (dBm) Tolerance ±(dB)

[2.4G WLAN] IEEE 802.11b(Peak)

Channel 01

Channel 06

14.0

13.0

1.0

1.0

IEEE 802.11g(Peak)

Channel 01

Channel 06

14.0

13.0

1.0

1.0

IEEE 802.11n20(Peak)

Channel 01

Channel 06

13.0

13.0

1.0

1.0

IEEE 802.11n40(Peak)

Channel 03

Channel 06

12.0

11.0

1.0

1.0

Channel 11 13.0 1.0
Channel 11 13.0 1.0
Channel 11 13.0 1.0
Channel 09 12.0 1.0

8. Measurement Results

8.1 Standalone MPE Evaluation

As declared by the Applicant, the EUT is a wireless device used in a fix application, at least 20 cm from any body part of the user or nearby persons; from the maximum EUT RF output power, the minimum separation distance, r =20cm, as well as the gain of the used antenna refer to antenna information, the RF power density can be obtained.

Modulation Type
BLE 1M GFSK BLE 2M GFSK

Output power

dBm

mW

2.0

1.5849

2.0

1.5849

[BLE] Antenna
Gain (dBi) 3.37 3.37

Antenna Gain (linear) 2.1727 2.1727

MPE (mW/cm2)
0.0007 0.0007

MPE Limits (mW/cm2) 1.0000 1.0000

Modulation Type
IEEE 802.11b IEEE 802.11g IEEE 802.11n HT20 IEEE 802.11n HT40

[2.4GWLAN]

Output power

dBm

mW

Antenna Gain (dBi)

15.0

31.6228

3.37

15.0

31.6228

3.37

14.0

25.1189

3.37

13.0

19.9526

3.37

Antenna Gain
(linear) 2.1727 2.1727 2.1727 2.1727

MPE (mW/cm2)
0.0137 0.0137 0.0109 0.0086

MPE Limits (mW/cm2) 1.0000 1.0000 1.0000 1.0000

Remark: 1. Output power including tune-up tolerance; 2. Output power was adjust to duty cycle at 100% if measured duty cycle less than 98%; 3. MPE evaluate distance is 20cm from user manual provide by manufacturer.
Shenzhen LCS Compliance Testing Laboratory Ltd. Add: 101, 201 Bldg A & 301 Bldg C, Juji Industrial Park Yabianxueziwei, Shajing Street, Baoan District, Shenzhen, 518000, China Tel: +(86) 0755-82591330 | E-mail: [email protected] | Web: www.lcs-cert.com Scan code to check authenticity

Page 11 of 11

FCC ID: 2BLJI-C20H

Report No.: LCSA04155033EC

8.2 Simultaneous Transmission MPE Evaluation The EUT equiped with one antenna. So no need consider simultaneous transmission.

9. Conclusion
The measurement results comply with the FCC Limit per 47 CFR 2.1091 for the uncontrolled RF Exposure of mobile device.

10. Description of Test Facility
NVLAP Accreditation Code is 600167-0. FCC Designation Number is CN5024. CAB identifier is CN0071. CNAS Registration Number is L4595. Test Firm Registration Number: 254912.

11. Measurement Uncertainty

BLE/2.4GWIFI:

Test Item

Frequency Range

Uncertainty

Note

Output power :

1GHz-40GHz

±0.57dB

(1)

(1). This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.

----------------THE END OF REPORT---------------