Read CUI’s specifications for SDI65-UD Series. Features include: 60 ~ 65 W - 12 ~ 56 Vdc output options - No-load power consumption < 0.15 W
CUI Inc
Future Electronics - The Edge
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 6 Pages, 553.96KB
Document DEVICE REPORT
✖
Additional Resources: Product Page | 3D Model SERIES: SDI65-UD DESCRIPTION: AC-DC POWER SUPPLY FEATURES · DoE Level VI, CoC Tier 2 efficiency · 65 W power · universal input (90~264 Vac) · compact size · single regulated output from 12~48 Vdc · over voltage and short circuit protections · UL/cUL, and PSE safety approvals · custom designs available · certified to 60950-1 and 62368-1 standards date 03/16/2023 page 1 of 6 MODEL output voltage (Vdc) output current max (A) output power max (W) ripple and noise1 max (mVp-p) efficiency level2 SDI65-12-UD 12 5 60 120 VI SDI65-15-UD 15 4.34 65 150 VI SDI65-18-UD 18 3.62 65 180 VI SDI65-19-UD 19 3.43 65 190 VI SDI65-24-UD 24 2.71 65 240 VI SDI65-48-UD 48 1.36 65 480 VI SDI65-56-UD 56 1.17 65.52 560 VI Notes: 1. At full load, nominal input, 20 MHz bandwidth oscilloscope, each output terminated with 0.1 F multilayer ceramic and 10 F low ESR electrolytic capacitors. 2. Coc Tier 2 compliant PART NUMBER KEY SDI65 - XX - UDX - XXX - CXX Base Number Output Voltage AC Inlet Type: IEC320/C8 Input Cable: "Blank" = No Cable C = North America input cable 2 = Europe input cable 3 = United Kingdom input cable 4 = Australia input cable 5 = China input cable 6 = South Korea input cable 7 = Brazil input cable 8 = South Africa input cable 9 = Japan input cable Reserved for Custom Configurations DC Plug Type: XXX = See output plug options on page 5 for more details cui.com Additional Resources: Product Page | 3D Model CUI Inc SERIES: SDI65-UD DESCRIPTION: AC-DC POWER SUPPLY date 03/16/2023 page 2 of 6 INPUT parameter voltage frequency current inrush current leakage current no load power consumption conditions/description at 240 Vac, full load, 25°C, cold start at 230 Vac OUTPUT parameter regulation conditions/description PROTECTIONS parameter over voltage protection over current protection short circuit protection conditions/description output latch off output shut down, auto recovery output shut down, auto recovery SAFETY & COMPLIANCE parameter conditions/description isolation voltage input to output at 10 mA for 1 minute isolation resistance input to output at 500 Vdc safety approvals UL/cUL (60950-1, 62368-1), PSE, LPS, UKCA EMI/EMC FCC Part 15B Class B, CE MTBF as per Telcordia SR-332, 25°C RoHS yes ENVIRONMENTAL parameter operating temperature storage temperature operating humidity storage humidity conditions/description 15 Vdc output model all other output models non-condensing non-condensing min 90 47 typ 100~240 50~60 max 264 63 1.4 80 0.25 0.150 units Vac Hz A A mA W min typ max units ±5 % min typ max units 150 % 180 % min 10 typ 3,000 max units Vac M 300,000 hours min typ max units 0 40 °C -20 40 °C -20 80 °C 20 80 % 10 90 % cui.com Additional Resources: Product Page | 3D Model CUI Inc SERIES: SDI65-UD DESCRIPTION: AC-DC POWER SUPPLY date 03/16/2023 page 3 of 6 MECHANICAL parameter dimensions inlet plug weight conditions/description 115 x 53 x 38 IEC320/C8 without ac cord MECHANICAL DRAWING units: mm tolerance: ±1.0 mm 115 min typ max units mm 310 g LED 38 DC CORD units: mm 80±5 53 cord length MODEL NO. SDI65-12-UD SDI65-15-UD SDI65-18-UD SDI65-19-UD SDI65-24-UD SDI65-48-UD SDI65-56-UD Table 1 CABLE UL1185, 16 AWG UL1185, 16 AWG UL2468, 18 AWG UL2468, 18 AWG UL2468, 18 AWG UL2468, 20 AWG UL2468, 22 AWG CORD LENGTH 1,500 mm ±30 1,500 mm ±30 1,500 mm ±30 1,500 mm ±30 1,500 mm ±30 1,500 mm ±30 1,500 mm ±30 cui.com Additional Resources: Product Page | 3D Model CUI Inc SERIES: SDI65-UD DESCRIPTION: AC-DC POWER SUPPLY AC CORD units: mm cord length date 03/16/2023 page 4 of 6 NORTH AMERICA EUROPE UNITED KINGDOM AUSTRALIA CHINA SOUTH KOREA BRAZIL SOUTH AFRICA JAPAN Table 2 AC INPUT North America Europe United Kingdom Australia China South Korea Brazil South Africa Japan CORD LENGTH 1,830 mm ±30 1,830 mm ±30 1,830 mm ±30 1,830 mm ±30 1,830 mm ±30 1,830 mm ±50 1,830 mm ±30 1,830 mm ±50 1,830 mm ±30 cui.com Additional Resources: Product Page | 3D Model CUI Inc SERIES: SDI65-UD DESCRIPTION: AC-DC POWER SUPPLY date 03/16/2023 page 5 of 6 DC PLUG TYPE PART NUMBER KEY X X X Plug Polarity: P = Center Positive N = Center Negative Plug Code: X = Choose a code from the options below Plug Angle: "blank" = Straight R = Right Angle Plug Polarity Code Center Pos. Center Neg. Option Type 5 Standard 6 Standard 7 Standard 8 Standard 9 Standard 10 Locking2 11 Locking2 12 EIAJ-1 13 EIAJ-2 14 EIAJ-3 N/A N/A ST Note: 1. Contact CUI for additional plug options 2. Maximum insertion depth is 10mm Dimensions (mm) A B C 5.5 2.1 9.5 5.5 2.5 9.5 3.5 1.35 9.5 3.8 1.35 9.5 3.8 1.05 9.5 5.5 2.1 9.5 5.5 2.5 9.5 2.35 0.7 9.5 4.0 1.7 9.5 4.75 1.7 9.5 Stripped & Tinned Plug Angle Straight Right N/A N/A N/A N/A Standard C C EIAJ C C Straight Right Angle (R) Locking C 2.5±0.3 Straight Right Angle (R) Stripped & Tinned 25±5 5±5 10±2 A B A B A B A B A B cui.com Additional Resources: Product Page | 3D Model CUI Inc SERIES: SDI65-UD DESCRIPTION: AC-DC POWER SUPPLY date 03/16/2023 page 6 of 6 REVISION HISTORY rev. 1.0 1.01 1.02 1.03 1.04 1.05 1.06 1.07 description date initial release 05/13/2015 updated datasheet 09/15/2016 added 62368-1 standard 08/31/2018 company logo updated 07/23/2020 UKCA added to specification 08/11/2021 plug polarity symbols updated 09/16/2021 dc plugs updated 05/23/2022 56 V output model added 03/16/2023 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.Adobe PDF Library 17.0