FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of
Digilife Technologies Co.,Ltd. Car Recorder
Model No.: u818x; DC800x; SP32; u808x Brand: HP
FCC ID: 2ACFI32WM
Prepared for : Digilife Technologies Co.,Ltd. 13F., No.7, Dexing W.Rd., Shilin Dist., Taipei City 11158, Taiwan
Prepared By : Audix Technology (Shenzhen) Co., Ltd. No. 6, Kefeng Road, Science & Technology Park, Nanshan District , Shenzhen, Guangdong, China Tel: (0755) 26639496
Report Number  ACS-F21299 Date of Test  Nov.08~12,2021 Date of Report  Dec.01,2021

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 1 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

TABLE OF CONTENTS

Description

Page

1. SUMMARY OF STANDARDS AND RESULTS ............................................................. 5 1.1. Description of Standards and Results ..................................................................................... 5
2. GENERAL INFORMATION............................................................................................. 6 2.1. Description of Equipment Under Test .................................................................................... 6 2.2. Feature of Equipment Under Test ........................................................................................... 7 2.3. Tested Supporting System Details .......................................................................................... 8 2.4. Block diagram of connection between the EUT and simulators............................................. 8 2.5. Test Information...................................................................................................................... 8 2.6. Test Facility ............................................................................................................................ 9 2.7. Measurement Uncertainty (95% confidence levels, k=2) ....................................................... 9
3. POWER LINE CONDUCTED EMISSION TEST ........................................................ 10

4. RADIATED EMISSION TEST ....................................................................................... 11
4.1. Test Equipment ..................................................................................................................... 11 4.2. Block Diagram of Test Setup ................................................................................................ 12 4.3. Radiated Emission Limit....................................................................................................... 13 4.4. EUT Configuration on Test .................................................................................................. 13 4.5. Operating Condition of EUT................................................................................................. 14 4.6. Test Procedure ...................................................................................................................... 14 4.7. Radiated Emission Test Results ............................................................................................ 14
5. CONDUCTED SPURIOUS EMISSIONS ....................................................................... 72
5.1. Test Equipment ..................................................................................................................... 72 5.2. Limit ...................................................................................................................................... 72 5.3. Test Procedure ...................................................................................................................... 72 5.4. Test result.............................................................................................................................. 72
6. BAND EDGE COMPLIANCE TEST ............................................................................. 82
6.1. Test Equipment ..................................................................................................................... 82 6.2. Limit ...................................................................................................................................... 82 6.3. Test Procedure....................................................................................................................... 82 6.4. Test Results ........................................................................................................................... 82
7. 6dB Bandwidth Test ........................................................................................................ 107
7.1. Test Equipment ................................................................................................................... 107 7.2. Limit .................................................................................................................................... 107 7.3. Test Procedure .................................................................................................................... 107 7.4. Test Results ......................................................................................................................... 107
8. OUTPUT POWER TEST ............................................................................................... 109
8.1. Test Equipment ................................................................................................................... 109 8.2. Limit (FCC Part 15C 15.247 b(3))...................................................................................... 109 8.3. Test Procedure .................................................................................................................... 109 8.4. Test Results ......................................................................................................................... 110
9. POWER SPECTRAL DENSITY TEST........................................................................ 112
9.1. Test Equipment ................................................................................................................... 112 9.2. Limit .................................................................................................................................... 112 9.3. Test Procedure .................................................................................................................... 112 9.4. Test Results ......................................................................................................................... 113
10. ANTENNA REQUIREMENT........................................................................................ 115
10.1. Standard Applicable ............................................................................................................ 115

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 2 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

10.2. Antenna Connected Construction ....................................................................................... 115 11. DEVIATION TO TEST SPECIFICATIONS ............................................................... 116

Appendix A. Photograph of Test Appendix B. Photo of the EUT

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 3 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

TEST REPORT CERTIFICATION

Applicant

 Digilife Technologies Co.,Ltd.

Manufacturer  Digilife Technologies Co.,Ltd.

Product

 Car Recorder

FCC ID

 2ACFI32WM

Model No.

 u818x; DC800x; SP32; u808x

Brand

 HP

Test Voltage

 DC 12V

Tested for comply with: FCC CFR 47 Part 15 Subpart C

Test procedure used: ANSI C63.10: 2013 KDB 558074 D01v05

The device described above is tested by AUDIX TECHNOLOGY (SHENZHEN) CO., LTD. to confirm comply with all the FCC Part 15 Subpart C requirements. The test results are contained in this test report and AUDIX TECHNOLOGY (SHENZHEN) CO., LTD. is assumed full responsibility for the accuracy and completeness of these tests. Also, this report shows that the Equipment Under Test (EUT) is to be technically compliant with the FCC and IC requirements. This report contains data that are not covered by the NVLAP accreditation.

This Report is made under FCC Part 2.1075. No modifications were required during testing to bring this product into compliance.

This report applies to single evaluation of one sample of above mentioned product. This report shall not be reproduced in part without written approval of AUDIX TECHNOLOGY (SHENZHEN) CO., LTD.
The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government.

Date of Test :

Nov.08~12,2021

Report of date:

Dec.01,2021

Prepared by :

Reviewed by :

Brave Zhang / Assistant

Sunny Lu / Deputy Manager

Approved & Authorized Signer :

David Jin / Deputy General Manager
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 4 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

1. SUMMARY OF STANDARDS AND RESULTS

1.1.Description of Standards and Results

The EUT has been tested according to the applicable standards as referenced below.

EMISSION

Description of Test Item

Standard

Results

Power Line Conducted Emission

FCC Part 15: 15.207

PASS

Radiated Emission

FCC Part 15: 15.209 FCC Part 15: 15.205

PASS

Band Edge Compliance

FCC Part 15: 15.247(d)

PASS

Conducted spurious emissions

FCC Part 15: 15.247(d)

PASS

6dB Bandwidth

FCC Part 15: 15.247(a)(2)

PASS

Peak Output Power

FCC Part 15: 15.247(b)(3)

PASS

Power Spectral Density

FCC Part 15: 15.247(e)

PASS

Antenna requirement

FCC Part 15: 15.203

PASS

Note: Measurement uncertainty affection to the result is considered, the EUT is technically compliant with standard requirements.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 5 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

2. GENERAL INFORMATION

2.1.Description of Equipment Under Test

Applicant

Digilife Technologies Co.,Ltd.

Applicant Address

13F., No.7, Dexing W.Rd., Shilin Dist., Taipei City 11158, Taiwan

Manufacturer

Digilife Technologies Co.,Ltd.

Manufacturer Address

13F., No.7, Dexing W.Rd., Shilin Dist., Taipei City 11158, Taiwan

Factory Factory Address Product Model No. Test Model

Shenzhen Xinghuafeng Technogy Co.,LTD.
201-301, Building 2, Xintang Industrial Park, Baishixia Area, Fuyong Town, Bao'an, Shenzhen, China
Car Recorder
u818x; DC800x; SP32; u808x Model differences (Declared by the Applicant): Only the model name is different.
u818x

Brand

HP

FCC ID

2ACFI32WM

Sample Type

Prototype production

Date of Receipt

Oct.29,2021

Date of Test

Nov.08~12,2021

Remark: This report only for WIFI 2.4GHz.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 6 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

2.2.Feature of Equipment Under Test

Product Model No.
Power Source
2.4GHz Wi-Fi

Product Feature & Specification

Car Recorder

u818x; DC800x; SP32; u808x

Commercial Power

AC 100~240 V

External Power Source

DC 12/24V

Li-ion battery

DC V, mAh

UM battery

DC V

Support Modes

802.11g/n20/n40

Frequency Range

2412-2462MHz

Type of Modulation

802.11g/n(OFDM): 64QAM, 16QAM, QPSK, BPSK

Data Rate

802.11g: 6/9/12/18/24/36/48/54 Mbps; 802.11n: up to 150Mbps

Channel Separation

5MHz

Antenna System Type of Antenna Antenna Peak Gain

Linear Antenna Peak Gain: 2dBi.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 7 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

2.3.Tested Supporting System Details
[None]

2.4.Block diagram of connection between the EUT and simulators

AC Mains

Adapter

EUT

(EUT: Car Recorder)

2.5.Test Information

--Mode
Info.
Data Rate (Mbps)
(see Note)

A special test software (ipop 4.0) was used to control EUT work in Continuous TX mode(The

duty cycle of the test signal is 100%), and select tested mode, channel, power setting and data

rate information as below:

Channel

Frequency (MHz)

Power setting

Channel

Frequency (MHz)

Power setting

Channel

Frequency (MHz)

Power setting

IEEE 802.11g

IEEE 802.11n HT20

IEEE 802.11n HT40

CH1

2412

44

CH1

2412

44

CH3

2422

44

CH2

2417

44

CH2

2417

44

CH4

2427

44

CH3

2422

44

CH3

2422

44

CH5

2432

44

CH4

2427

44

CH4

2427

44

CH6

2437

44

CH5

2432

44

CH5

2432

44

CH7

2442

44

CH6

2437

44

CH6

2437

44

CH8

2447

44

CH7

2442

44

CH7

2442

44

CH9

2452

44

CH8

2447

44

CH8

2447

44

---

---

---

CH9

2452

44

CH9

2452

44

---

---

---

CH10

2457

44

CH10

2457

44

---

---

---

CH11

2462

44

CH11

2462

44

---

---

---

6

MCS0

MCS0

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 8 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

2.6. Test Facility
Site Description Name of Firm
EMC Lab.

Audix Technology (Shenzhen) Co., Ltd. : No. 6, Kefeng Road, Science & Technology Park,
Nanshan District , Shenzhen, Guangdong, China

Certificated by ISED, Canada

:

Company Number: 5183A CAB identifier: CN0034

Valid Date: Mar.31, 2022

Certificated by FCC, USA : Designation No.: CN5022
Valid Date: Mar.31, 2022

Accredited by NVLAP, USA : NVLAP Code: 200372-0
Valid Date: Mar.31, 2022

2.7.Measurement Uncertainty (95% confidence levels, k=2)

Test Item
Uncertainty for Radiation Emission test in 3m chamber
Uncertainty for Radiation Emission test in 3m chamber(1GHz-18GHz)
Uncertainty for Radiated Spurious Emission test
Uncertainty for Conduction Spurious emission test
Uncertainty for Output power test Uncertainty for Bandwidth test Uncertainty for DC power test
Uncertainty for test site temperature and humidity

Uncertainty 3.2dB(30~200MHz, Polarization: H) 3.6dB(30~200MHz, Polarization: V) 3.4dB(200M~1GHz, Polarization: H) 3.4dB(200M~1GHz, Polarization: V)
5.0dB(1GHz~6GHz) 5.2dB(6GHz~18GHz) 3.7dB(30MHz~1000MHz)
3.3dB(1~26.5GHz)
2.0dB
0.8dB 83kHz 1.0% 0.6
3%

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 9 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

3. POWER LINE CONDUCTED EMISSION TEST
According to Paragraph (c) of FCC Part 15 section 15.207, Tests to demonstrate compliance with the conducted limits are not required for devices which only employ battery power for operation and which do not operate from the AC power lines or contain provisions for operation while connected to the AC power lines.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 10 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

4. RADIATED EMISSION TEST

4.1.Test Equipment

4.1.1. For frequency range 30MHz~1000MHz (In 3m Anechoic Chamber)

Item

Equipment

Manufacturer

Model No.

Serial No. Last Cal.

1. 3#Chamber(NSA)

AUDIX

N/A

N/A

May.02,21

2. 3#Chamber(SE)

AUDIX

N/A

N/A

May.17,18

3. Signal Analyzer Rohde & Schwarz

FSV30

104050

Apr.07,21

4. EMI Test Receiver Rohde & Schwarz

ESR3

102891

Oct.20,21

5.

Amplifier

HP

8447D

2648A04738 Apr.08,21

6.

Bi log Antenna

TESEQ

CBL6112D

25237

Dec.22,20

7.

NSA Cable

HUBER+SUHNER CFD400NL-LW

No.3

Oct.09,21

8.

Coaxial Switch

Anritsu

MP59B

6201397223 Apr.07,21

9.

Test Software

AUDIX

e3

6.2009-5-21a(n) N/A

Note: N/A means Not applicable.

Cal. Interval 1 Year 5 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year
N/A

4.1.2. For frequency range 1GHz~25GHz (In 3m Anechoic Chamber)

Item Equipment

Manufacturer

Model No.

Serial No.

1. 3#Chamber(Svswr)

AUDIX

N/A

N/A

Last Cal.

Cal. Interval

Apr.14,21 1 Year

2. 3#Chamber(SE)

AUDIX

N/A

N/A

May.17,18 5 Year

3. Signal Analyzer Rohde & Schwarz

FSV30

104050

Apr.07,21 1 Year

4. Horn Antenna

ETC

MCTD 1209 DRH15F03006 Jul.26,21 1 Year

5. Horn Antenna

ETS

3116

00060089 Dec.09,20 1 Year

6.

Amplifier

HP

8449B

3008A02495 Apr.07,21 1 Year

7.

Amplifier

EMCI

EMC184040SE

980507

Apr.08,21 1 Year

8.

RF Cable

HUBER+SUHNER SUCOFLEX-106 505238/6 Apr.07,21 1 Year

9. Test Software

AUDIX

e3

6.100913a

N/A

N/A

Note: N/A means Not applicable.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 11 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

4.2.Block Diagram of Test Setup
For frequency range 30MHz-1000MHz
Semi-anechoic 3m Chamber

ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS
3.0m

(Reference Point)

EUT

2.0m(L)*1.0m(W)*0.8m(H)

TURN TABLE (FIBRE GLASS)

0.8m

Coaxial Switch Receiver

AMP Spectrum Analyzer PC System

For frequency range 1GHz-25GHz
Full-anechoic 3m Chamber
ANTENNA ELEVATION VARIES FROM 1 TO 4 METERS

3m (Reference Point)

EUT

1.0m(L)*1.0m(W)*1.5m(H) ABSORBER (30cm maximum)
(30cm)

TURN TABLE (Styrene)

AMP Spectrum Analyzer PC System

1.5m

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 12 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

4.3.Radiated Emission Limit

4.3.1. 15.247&209 limits

FREQUENCY

DISTANCE

FIELD STRENGTHS LIMIT

MHz

Meters

V/m

dB(V)/m

30 ~ 88

3

100

40.0

88 ~ 216

3

150

43.5

216 ~ 960

3

200

46.0

960 ~ 1000

3

500

54.0

Above 1000

3

74.0 dB(V)/m (Peak)

54.0 dB(V)/m (Average)

Remark (1) Emission level dBV = 20 log Emission level V/m

(2) The smaller limit shall apply at the cross point between two frequency bands. (3) Distance is the distance in meters between the measuring instrument, antenna
and the closest point of any part of the device or system.

4.3.2. 15.205 Restricted bands of operation

All the emissions appearing within 15.205 restricted frequency bands shall not exceed the limits shown in 15.209, all the other emissions shall be at least 20dB below the fundamental emissions, or comply with 15.209 limits.
4.4.EUT Configuration on Test
The following equipment are installed on Power Line Conducted Emission Test to meet the commission requirement and operating regulations in a manner which tends to maximize its emission characteristics in a normal application. 4.4.1. Car Recorder (EUT)
Model No. : u818x Serial No. : N/A 4.4.2. Support Equipment: As Tested Supporting System Details, in Section 2.2.
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 13 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

4.5.Operating Condition of EUT
4.5.1. Setup the EUT and simulator as shown as Section 4.2. 4.5.2. Turn on the power of all equipments. 4.5.3. Let EUT work in Tx(WiFi 2.4GHz) mode
4.6.Test Procedure
Frequency below 30MHz: The EUT setup on the turn table which has 0.8 m height to the ground. The turn table rotated 360 degrees and antenna fixed to 1 m to find the maximum emission level. In order to find the maximum emission, all of the interface cables were manipulated according to ANSI C63.10-2013 regulation.
EUT and its simulators are placed on a turn table, which is 0.8 meter high above ground for frequency 30MHz~1000MHz, 1.5 meter high above ground for frequency above 1GHz and put the absorbing with 2.4m(L)*2.4m(W)*0.3m(H) on the ground. The turn table can rotate 360 degrees to determine the position of the maximum emission level. Power on the EUT and let it working in test mode, then test it.EUT is set 3 meters away from the receiving antenna, which is mounted on a antenna tower. The antenna can be moved up and down between 1 meter and 4 meters to find out the maximum emission level. Broadband antenna (calibrated bilog antenna) is used as receiving antenna for frequency 30MHz~1000MHz, and the Horm antenna is used as receiving antenna for frequency above 1GHz. Both horizontal and vertical polarization of the antenna are set on test.
This test was performed with EUT in X, Y, Z position, and the worse case was found when EUT in X position as test photo indicated.
The bandwidth of the EMI test receiver (R&S ESR3) is set at 120kHz for frequency range from 30MHz to 1000 MHz.
The bandwidth of the Spectrum's VBW is set at 3MHz and RBW is set at 1MHz for peak emissions measurement above 1GHz and 1MHz RBW, 10Hz VBW for average emissions measure above 1GHz
The frequency range from 30MHz to 10th harmonic (25GHz) are checked. and no any emissions were found from 18GHz to 25GHz, So the radiated emissions from 18GHz to 25GHz were not record.
4.7.Radiated Emission Test Results
PASS.
All the emissions from 30MHz to 25 GHz were comply with 15.209 limits.
Note 1: For emissions above 1GHz, if peak level comply with average limit, then the average level is deemed to comply with average limit. Note 2: The emissions (9kHz~30MHz) not reported for there is no emission be found.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 14 of 116

FCC ID:2ACFI32WM
Duty cycle

AUDIX Technology (Shenzhen) Co., Ltd.

Note: The duty cycle of the test signal is 100%.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 15 of 116

FCC ID:2ACFI32WM
Frequency: 30MHz~1GHz

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 16 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 17 of 116

FCC ID:2ACFI32WM
Frequency: 1GHz~18GHz

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 18 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 19 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 20 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 21 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 22 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 23 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 24 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 25 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 26 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 27 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 28 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 29 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 30 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 31 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 32 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 33 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 34 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 35 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 36 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 37 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 38 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 39 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 40 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 41 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 42 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 43 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 44 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 45 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 46 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 47 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 48 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 49 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 50 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 51 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 52 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 53 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 54 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 55 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 56 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 57 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 58 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 59 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 60 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 61 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 62 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 63 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 64 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 65 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 66 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 67 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 68 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 69 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 70 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 71 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.

5. CONDUCTED SPURIOUS EMISSIONS

5.1.Test Equipment

Item Equipment

1.

PXA Signal Analyzer

Manufacturer Agilent

Model No. N9030A

2. Attenuator

Agilent

8491B

3. RF Cable HUBER+SUHNER SUCOFLEX-106

Serial No. MY51380221 MY39269201
505238/6

Last Cal. Cal. Interval

Apr.07,21 1 Year

Oct.09,21 Apr.07,21

1 Year 1 Year

5.2. Limit

In any 100kHz bandwidth outside the frequency bands in which the spread spectrum intentional radiator in operating, the radio frequency power that is produced by the intentional radiator shall be at least 30dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired power.
5.3.Test Procedure

The transmitter output was connected to a spectrum analyzer, The resolution bandwidth is set to 100 kHz, The video bandwidth is set to 300 kHz and measure all the emissions with peak detector.

5.4.Test result
PASS (The testing data was attached in the next pages.)

EUT: Car Recorder M/N: u818x Test date:2021-11-12 Tested by: Lily

Pressure: 102.7±1.0 kpa Test site: RF site

Humidity: 52.6±3.0% Temperature:23.1±0.6 

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 72 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.
Test Mode: IEEE 802.11g Test CH1: 2412MHz

--
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 73 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.
Test CH6: 2437MHz

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 74 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.
Test CH11: 2462MHz

--
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 75 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.
Test Mode: IEEE 802.11n HT20 Test CH1: 2412MHz

--
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 76 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.
Test CH6: 2437MHz

Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 77 of 116

FCC ID:2ACFI32WM

AUDIX Technology (Shenzhen) Co., Ltd.
Test CH11: 2462MHz

--
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F21299 Page 78 of 116



Related FCC IDs:

Search Any Device: