EN55022&24 report

leon chen

Test Report

Shenzhen Tengsay Technology Co., Ltd T29 2BGF3-T29 2BGF3T29 t29

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 32 Pages, 3.47MB

Document DEVICE REPORTGetApplicationAttachment.html?id=7626484
- Page 1 of 32 -

Report No.: HB20240813005E-01

Test Report

Product: 3-in-1 Wireless Charging Station Trade Mark: N/A Model Number: T29
FCC ID: 2BGF3-T29
Prepared for Shenzhen Tengsay Technology Co., Ltd 502, No.7, Xikeng South Road, Xikeng Community, Fucheng Street,
Longhua District, Shenzhen, China
Prepared by Shenzhen HongBiao Certification& Testing Co., Ltd Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,
China Tel.: +86-755-2998 9321 Fax.: +86-755-2998 5110
Website: http://www.sz-hongbiao.com

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 2 of 32 -

Report No.: HB20240813005E-01

Table of Contents
1 GENERAL DESCRIPTION ..................................................................................................................................... 5
1.1 DESCRIPTION OF EUT ................................................................................................................................................ 5 1.2 TEST MODE.............................................................................................................................................................. 5 1.3 TEST SETUP .............................................................................................................................................................. 6 1.4 ANCILLARY EQUIPMENT .............................................................................................................................................. 6
2 SUMMARY OF TEST RESULT ............................................................................................................................... 7
3 TEST FACILITIES AND ACCREDITATIONS .............................................................................................................. 8
3.1 TEST LABORATORY ..................................................................................................................................................... 8 3.2 ENVIRONMENTAL CONDITIONS ..................................................................................................................................... 8 3.3 MEASUREMENT UNCERTAINTY ..................................................................................................................................... 8 3.4 TEST SOFTWARE ........................................................................................................................................................ 8
4 LIST OF TEST EQUIPMENT .................................................................................................................................. 9
5 TEST ITEM AND RESULTS...................................................................................................................................12
5.1 ANTENNA REQUIREMENT .......................................................................................................................................... 12 5.2 CONDUCTED EMISSION............................................................................................................................................. 13 5.3 RADIATED EMISSION ................................................................................................................................................ 17 5.4 OCCUPIED BANDWIDTH ............................................................................................................................................ 22
6 PHOTOGRAPHS OF THE TEST SETUP..................................................................................................................24
7 PHOTOGRAPHS OF THE EUT..............................................................................................................................26

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 3 of 32 -

Report No.: HB20240813005E-01

TEST RESULT CERTIFICATION

Applicant's Name................. : Address ................................. : Manufacturer's Name .......... : Address ................................. : Product description

Shenzhen Tengsay Technology Co., Ltd 502, No.7, Xikeng South Road, Xikeng Community, Fucheng Street, Longhua District, Shenzhen, China Shenzhen Tengsay Technology Co., Ltd 502, No.7, Xikeng South Road, Xikeng Community, Fucheng Street, Longhua District, Shenzhen, China

Product name ........................ : 3-in-1 Wireless Charging Station

Model Number ....................... : T29 Standards ............................. : FCC Part 15C Test procedure....................... : IEEE/ANSI C63.10-2020 This device described above has been tested by Shenzhen HongBiao Certification& Testing Co., Ltd and the test results show that the equipment under test (EUT) is in compliance with the EMC requirements. And it is applicable only to the tested sample identified in the report.

Date of Test ........................................... :

Date (s) of performance of tests ............. : Aug. 13, 2024~ Aug. 22, 2024

Test Result.............................................. : Pass

Testing Engineer

:

(Zoe Su)

Technical Manager :

(Mark Chen)

Authorized Signatory :

(Leo Su)

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

Revised No. 01

- Page 4 of 32 -

Report No.: HB20240813005E-01

Revision History
Date of Issue Aug. 27, 2024

Description Original

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 5 of 32 -

Report No.: HB20240813005E-01

1 General Description
1.1 Description of EUT

Product name: Model name: Series Model: Different of series model:
Operation frequency:
Operational mode: Modulation type: Antenna type: Hardware version: Software version: Battery:
Power supply:
Adapter information: 1.2 Test Mode

3-in-1 Wireless Charging Station
T29
N/A
N/A Watch: 320kHz Phone: 115kHz~205kHz TWS: 115kHz~205kHz Wireless charging
ASK
Coil Antenna
V1.0
V1.0
N/A Input: DC 9V/3A Wireless Output: For Phone 15W Max Wireless Output: For iPhone 7.5W Max Wireless Output: For TWS 5W Max Wireless Output: For Watch 3W Max N/A

Pretest Test Mode 1 2 3 4

Description of Mode Wireless Output (Phone: 5W+TWS: 5W+Watch: 3W) Wireless Output (Phone: 7.5W+TWS: 5W+Watch: 3W) Wireless Output (Phone: 10W+TWS: 5W+Watch: 3W) Wireless Output (Phone: 15W+TWS: 5W+Watch: 3W)

Test Item

Final Test Mode

Conducted Emissions

4

Radiated Emissions

4

20dB bandwidth

4

Note: All modes have been tested, and the report only reflects the test results of the worst mode (Final Test Mode).

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 6 of 32 -

Report No.: HB20240813005E-01

1.3 Test Setup
See photographs of the test setup in the report for the actual setup and connections between EUT and support equipment.

1.4 Ancillary Equipment Equipment Adapter

Model TA65B

Load

YBZ1.1

Air Pods

A2031

Watch

NYYK2CH/A

S/N
2S36003438 PL97T09582 86631yp378-
220519 H04F3NS0L
X2Y H4HFR0ZHQ
1N2

Manufacturer Nanjing Bolande Electronic
Technology Co., Ltd YBZ
Apple Inc.
Apple Inc.

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 7 of 32 -

Report No.: HB20240813005E-01

2 Summary of Test Result
Test procedures according to the technical standards: FCC Part 15C

No.

Standard Section

Test Item

1

FCC Part 15.203

Antenna Requirement

2

FCC Part 15.207

Conducted Emission

3

FCC Part 15.209

Radiated Emission

4

FCC Part 15.215

20dB Bandwidth

Note: 1. "N/A" means the test case does not apply to the test object.

Result
Pass Pass Pass Pass

Remark

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 8 of 32 -

Report No.: HB20240813005E-01

3 Test Facilities and Accreditations

3.1 Test Laboratory

Test Site
Test Site Location
Telephone: Fax: FCC Registration No.: A2LA Certificate No.:

Shenzhen HongBiao Certification& Testing Co., Ltd Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen, China (86-755) 2998 9321
(86-755) 2998 5110
CN1341
6765.01

3.2 Environmental Conditions

During the measurement the environmental conditions were within the listed ranges:

Temperature:

15ºC~35ºC

Relative Humidity:

20%~75%

Air Pressure:

98kPa~101kPa

3.3 Measurement Uncertainty
The reported uncertainty of measurement y ± U, where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence of approximately 95 %. The data and results quoted in this document are true and accurate values, and uncertainties are not involved in the calculations. In addition, components and mass production processes that are similar to testing equipment may introduce additional deviations, and the manufacturer is solely responsible for the continued compliance of the equipment.

Measurement Frequency Range RF frequency
RF power, conducted Conducted emission(150kHz~30MHz)
Radiated emission(9kHz-30MHz) Radiated emission(30MHz~1GHz) Radiated emission (above 1GHz)
Occupied Bandwidth Temperature Humidity

U(dB) 2x 10-5 ± 0.57 dB ± 2.5 dB ± 2.5 dB ± 4.2 dB ± 4.7 dB
±3% ±1 degree
±5 %

Note

3.4 Test Software

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 9 of 32 -

Report No.: HB20240813005E-01

Software name Conducted Emission test Software Radiated Emission test Software
RF Test System

Manufacturer Farad Farad MWRF

Model EZ-EMC EZ-EMC MTS 8310

Version EMC-CON 3A1.1+
FA-03A2 2.0.0.0

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 10 of 32 -

Report No.: HB20240813005E-01

4 List of Test Equipment

Radiation emission

Item

Equipment No.

Equipment name

Manufacturer

Model

Serial No.

Calibration date

Due date

1

HB-E001 Horn Antenna Schwarzbeck

BBHA 9120D

02592

2024-05-18 2026-05-17

Biconical

2

HB-E002

log-periodic composite

Schwarzbeck

VULB 9168

01340

2024-05-18 2026-05-17

antenna

3

HB-E003

SHF-EHF Horn

Schwarzbeck

BBHA 91270

01193

2024-05-18 2026-05-17

4

HB-E005 Preamplifier Noyetec

LAN-01 NYCM1420

18

102

2024-05-17

2025-05-16

5

HB-E006 Preamplifier Noyetec

LAN-18 NYCM1420

40

103

2024-05-17

2025-05-16

6

HB-E007

EMI TEST RECEIVER

R&S

ESR7

102520 2024-05-17 2025-05-16

POSITINAL

7

HB-E009 COTROLLE Noyetec

N/A

N/A

/

/

R

8

HB-E013 RF switch

Noyetec

NY-RF4

NY0CM142 0204

/

/

9

HB-E066

Illuminance Tester

TASI

TA8121

N/A

2024-05-21 2025-05-20

10

HB-E075

Active loop antenna

Schwarzbeck

FMZB 1519B

1519B-245 2024-05-18 2026-05-17

11

HB-E076 Preamplifier

Hewlett Packard

8447D

1937A0227 8

2024-05-17

2025-05-16

Conduction emission

Item

Equipment No.

Equipment name

Manufactu rer

1

HB-E014

4 Path V-LISN

Schwarzb eck

2

HB-E015

Pulse Limiter

Schwarzb eck

Model
NNLK 8121 VTSD 9561-F

Serial No. 00770 00949

Calibration date
2024-05-17

Due date 2025-05-16

2024-05-17 2025-05-16

3

HB-E016 ZN23201 Noyetec ZN23201

N/A

2024-05-21 2025-05-20

4

HB-E059 Attenuator Xianghua TS2-6-1 220215166 2024-05-17 2025-05-16

5

HB-E069

EMI TEST RECEIVER

R&S

ESCI

N/A

2024-05-17 2025-05-16

RF

Item

Equipmen t No.

Equipment name

Manufact urer

Model

Serial No.

Calibration date

Due date

MXG Anaiog

1 HB-E041

Signal

Agilent N5181A MY47070421 2024-05-17 2025-05-16

Generator

WIDEBAND

2 HB-E042

RADIO

R&S

CMW500

132108

2024-05-17 2025-05-16

COMMUNICA

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 11 of 32 -

Report No.: HB20240813005E-01

TION TESTER

MXG Anaiog

3 HB-E043

Signal

Agilent N5182A US46240335 2024-05-17 2025-05-16

Generator

Signal&

4 HB-E044

spectrum

R&S FSV3044

101264

2024-05-17 2025-05-16

Analyzer

5

HB-E045

RF Control Box

Noyetec

NY100-R FCB

N/A

/

/

Thermometer

6 HB-E058 Clock Humidity N/A

HTC-1

N/A

/

/

Monitor

Note: the calibration interval of the above test instruments is 12&24 months and the calibrations are traceable to international system unit (SI).

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 12 of 32 -

Report No.: HB20240813005E-01

5 Test Item And Results
5.1 Antenna Requirement
5.1.1 Standard Requirement 15.203 requirement: For intentional device, according to 15.203: an intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible party shall be used with the device
5.1.2 Test Result The EUT antenna is Coil Antenna. It comply with the standard requirement. In case of replacement of broken antenna the same antenna type must be used.

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 13 of 32 -

Report No.: HB20240813005E-01

5.2 Conducted Emission 5.2.1 Limits

Limits ­ Class A

Frequency (MHz)

Limit (dBµV) Quasi-Peak

Average

0.15 to 0.5

79

66

0.5 to 30

73

60

Limits ­ Class B

Frequency (MHz)

Limit (dBµV) Quasi-Peak

Average

0.15 to 0.5

66 to 56*

56 to 46*

0.5 to 5

56

46

5 to 30

60

50

Note: 1. the tighter limit applies at the band edges. 2. the limit of " * " marked band means the limitation decreases linearly with the logarithm of the frequency in
the range.

5.2.2 Test Procedures
a) The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected to the power mains through a line impedance stabilization network (LISN). All other support equipment powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling impedance for the measuring instrument.
b) Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and forth in the center forming a bundle 30 to 40 cm long.
c) I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the cable may be terminated, if required, using the correct terminating impedance. The overall length shall not exceed 1 m.
d) LISN is at least 80 cm from nearest part of EUT chassis.
e) For the actual test configuration, please refer to the related Item ­ photographs of the test setup.

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

5.2.3 Test setup

- Page 14 of 32 -

Report No.: HB20240813005E-01

5.2.4 Test Result

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 15 of 32 -

Report No.: HB20240813005E-01

EUT: Test Mode: Test Voltage:

3-in-1 Wireless Charging Station
Mode 4

Model Name: T29

Phase:

L

DC 9V from adapter AC 120V/60Hz

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 16 of 32 -

Report No.: HB20240813005E-01

EUT: Test Mode: Test Voltage:

3-in-1 Wireless Charging Station
Mode 4

Model Name: T29

Phase:

N

DC 9V from adapter AC 120V/60Hz

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 17 of 32 -

Report No.: HB20240813005E-01

5.3 Radiated Emission 5.3.1 Limits
Frequencies (MHz)
0.009~0.490 0.490~1.705 1.705~30.0
30~88 88~216 216~960 Above 960

Field Strength (micorvolts/meter)
2400/F(KHz) 24000/F(KHz)
30 100 150 200 500

Measurement Distance (meters) 300 30 30 3 3 3 3

Receiver Parameter Attenuation
Start ~ Stop Frequency Start ~ Stop Frequency Start ~ Stop Frequency

Setting Auto
9kHz~150kHz / RB 200Hz for QP 150kHz~30MHz / RB 9kHz for QP 30MHz~1000MHz / RB 120kHz for QP

5.3.2 Test Procedures
a) The radiated emission tests were performed in the 3 meters. b) The EUT was placed on the top of a rotating table 0.8 meters above the ground. The table
was rotated 360 degrees to determine the position of the highest radiation. c) The height of the test antenna shall vary between 1m to 4m. Both horizontal and vertical
polarizations of the antenna are set to make the measurement. d) If the peak mode measured value compliance with and lower than quasi peak mode limit, the
EUT shall be deemed to meet QP limits and then no additional QP mode measurement performed. e) If the peak mode measured value compliance with and lower than average mode limit, the EUT shall be deemed to meet average limits and then no additional average mode measurement performed. f) For the actual test configuration, please refer to the related item ­ EUT test photos.
5.3.3 Test Setup

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 18 of 32 -
Radiated Emission Test-Up Frequency Below 30MHz

Report No.: HB20240813005E-01

Radiated Emission Test-Up Frequency 30MHz~1GHz

5.3.4 Test Result

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 19 of 32 -

Report No.: HB20240813005E-01

Frequency range (9kHz ­ 30MHz)

EUT: Test Mode:

3-in-1 Wireless Charging Station
Mode 4

Model Name: Phase:

Test Voltage: DC 9V from adapter AC 120V/60Hz

T29 Coaxial

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 20 of 32 -

Report No.: HB20240813005E-01

Frequency range (30MHz ­ 1GHz)

EUT: Test Mode:

3-in-1 Wireless Charging Station
Mode 4

Model Name: Phase:

Test Voltage: DC 9V from adapter AC 120V/60Hz

T29 Vertical

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 21 of 32 -

Report No.: HB20240813005E-01

EUT: Test Mode: Test Voltage:

3-in-1 Wireless Charging Station
Mode 4

Model Name: Phase:

DC 9V from adapter AC 120V/60Hz

T29 Horizontal

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 22 of 32 -

Report No.: HB20240813005E-01

5.4 Occupied Bandwidth
5.4.1 Test method
Use the following spectrum analyzer settings: Span = approximately 2 to 3 times the 20 dB bandwidth, centered on a hopping channel RBW 1% of the 20 dB bandwidth VBW RBW Sweep = auto Detector function = peak Trace = max hold The EUT should be transmitting at its maximum data rate. Allow the trace to stabilize. Use the marker-to-peak function to set the marker to the peak of the emission. Use the marker-delta function to measure 20 dB down one side of the emission. Reset the marker-delta function, and move the marker to the other side of the emission, until it is (as close as possible to) even with the reference marker level. The marker-delta reading at this point is the 20 dB bandwidth and 99% occupied bandwidth of the emission.
5.4.2 Test result

Frequency (kHz) 119
Phone: Test plots as below:

20dB emission bandwidth (Hz) 759.20

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 23 of 32 -

Report No.: HB20240813005E-01

Frequency (kHz) 320
Watch: Test plots as below:

20dB emission bandwidth (Hz) 809.20

Frequency (kHz) 127
TWS: Test plots as below:

20dB emission bandwidth (Hz) 764.20

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 24 of 32 -

Report No.: HB20240813005E-01

6 Photographs of the Test Setup
Radiated Emission Below 30MHz

Radiated Emission Above 30MHz

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 25 of 32 -

Report No.: HB20240813005E-01

Conducted Emission

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 26 of 32 -
7 Photographs of the EUT
Photo 1

Report No.: HB20240813005E-01

Photo 2

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 27 of 32 Photo 3

Report No.: HB20240813005E-01

Photo 4

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 28 of 32 Photo 5

Report No.: HB20240813005E-01

Photo 6

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 29 of 32 Photo 7

Report No.: HB20240813005E-01

Photo 8

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 30 of 32 Photo 9

Report No.: HB20240813005E-01

Photo 10

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 31 of 32 Photo 11

Report No.: HB20240813005E-01

Photo 12

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com

- Page 32 of 32 Photo 13

Report No.: HB20240813005E-01

****** END OF REPORT ******

Add:Room 102, 201, Building 2, Yuanwanggu RFID Industrial Park, Tongguan Road, Tianliao Community, Yutang Street, Guangming District, Shenzhen,China

Tel: (86-755) 29989321

Fax: (86-755) 29985110

Web:www.sz-hongbiao.com



Related FCC IDs:

Search Any Device: