Document DEVICE REPORTGCNV-VD00-3834 BrochureInverter Series Up to 70 EER DC Inverter Geothermal Heat Pump Embrace comfort with the GeoCool® all DC Inverter Technology. Equipped with the highprecision Electronic Expansion Valve, allowing for more accurate temperature control while also keeping the utility bill down. The flexibility of four independent modules makes it easy to meet the installation requirements of different air outlet methods and applications. Space constraints are less of an issue when a custom built layout is an option! For a long term solution with lower maintenance costs, design your own GeoCool® Inverter Series Geothermal unit. COMING SOON! All DC Inverter High-Precision Electronic Expansion Valve (EEV) Co-Axial Copper-Nickel Coil Heat Exchanger Durable Build & Finish Multi-Position Installation Low Noise Version Date: 08-01-23 www.mrcool.com Inverter Series GeoCool Vertical Downflow with pre-charged GeoCool Quick Connect Line Set A-Coil Module: GCSCAM060GN Blower Module: GCSBLM014 Compressor: GCSHPM060IN GeoCool No-Vac Vertical Downflow w/o Air Box 3/8 3/4 Prechg. Lineset: GCNV-VD00-3834 GeoCool Vertical Upflow with pre-charged GeoCool Quick Connect Line Set Blower Module:GCSBLM0141 A-Coil Module: GCSCAM060GN Compressor: GCSHPM060IN GeoCool No-Vac Vertical Upflow w/ Air Box 3/8 3/4 Prechg. Lineset: GCNV-VUAB-3834 GeoCool Vertical Upflow with Return Air Box and pre-charged GeoCool Quick Connect Line Set Blower Module: GCSBLM0141 A-Coil Module: GCSCAM060GN Return Air Box Module: GCSAR048060 Compressor: GCSHPM060IN GeoCool No-Vac Vertical Upflow w/ Air Box 3/8 3/4 Prechg. Lineset: GCNV-VU00-3834 SPECIFICATIONS* *Specifications are preliminary and subject to change. OPEN LOOP COOLING HEATING CLOSED LOOP COOLING HEATING MODEL LOAD FLUID FLOW AIRFLOW AIRFLOW CAPACITY EER CAPACITY COP CAPACITY EER CAPACITY COP (GPM) (COOLING CFM) (HEATING CFM) (BTU/HR) (BTU/HR) (BTU/HR) (BTU/HR) ____________________________________________________________________________________________________________________________________________________________________ 4 TON ____F_U__L_L___________8____________1_4_0__0_________17__5_0__________5_3_2_0_0_________2_7___________4_8__0_0_0________4_._3__________4__8_0_0_0__________1_9___________4_0__0_0_0_________3_._4__ PART 8 810 1050 13300 71 11000 5.9 14500 48.8 9800 5.1 ________________________________________________________________________________________________________________________________________________________ 5 TON ____F_U__L_L_________7__.9_3___________1_4_0__0_________17__5_0_________6__2_0_0_0________2_1_.3_9__________5_5_0__0_0________3_._7__________5__5_6_0_0_________1_4_.4___________4_5__0_0_0_________3_._2__ PART 7.93 810 1050 13300 70.97 11000 5.9 14500 48.79 9800 5.1 ____________________________________________________________________________________________________________________________________________________________________ ALL RATINGS BASED ON 208V / 60Hz / 1ph. HEATING CAPACITIES BASED ON 68.0°F DB / 59.0°F WB ENTERING AIR TEMPERATURE. COOLING CAPACITIES BASED ON 80.6°F DB / 66.2°F WB ENTERING AIR TEMPERATURE. GeoCool Vertical Split System with Return Air Box and MRCOOL Pre- Charged Line Set If limited access is a space constraint, a Vertical Split system may be the ideal configuration. A Vertical Split configuration would include a stand alone Compressor Module, separate from the A-coil Module, Blower Module, and Return Air Box. This system would require the use of the MRCOOL No-Vac Quick Connect line set. MRCOOL offers multiples lengths for various application requirements.* To build this configuration, all items will need to be selected and purchased individually. From top to bottom, this configuration includes the following units: Blower Module: GCSBLM0141 A-Coil Module: GCSCAM060GN Return Air Box Module: GCSAR048060 Compressor: GCSHPM060IN MRCOOL No-Vac Quick Connect line set: NVXX-3834 *Refer to MRCOOL Pre-Charged Line Sets for selection. GeoCool Horizontal Split System with MRCOOL Pre-Charged Line Set If there is limited access to a space, a Horizontal Split system may be the choice. This split configuration would include a stand-alone Compressor Module, separate from the A-coil Module and Blower Module in a horizontal orientation. This system would require the use of the MRCOOL No-Vac Quick Connect line set. MRCOOL offers multiples lengths for various application requirements.* To build this configuration, all items will need to be selected and purchased individually. From left to right, this configuration includes the following units: Blower Module: GCSBLM0141 A-Coil Module: GCSCAM060GN Compressor: GCSHPM060IN MRCOOL No-Vac Quick Connect line set: NVXX-3834 *Refer to MRCOOL Pre-Charged Line Sets for selection. *All modules must be selected individually based on the desired configuration. Currently, there is not a model number for an entire system. The Vertical Up-flow (with or without the return air box) and Vertical Down-flow configurations have line sets designed for each system. Split Systems will require the user to select and purchase a MRCOOL Universal No-Vac line set based on the distance required for the application. Refer to your dealer to purchase the additional, required accessories to complete a full geothermal system. A-Coil Module GCSCAM060GN Net Cabinet Dimensions: A: 24.81" (630mm) C B: 22.43" (570mm) C: 30.87" (785mm) Net Weight: 124.58 Lbs (56.5Kg) Compressor Module GCSHPM060IN Net Cabinet Dimensions: A: 24.81" (630mm) B: 22.43" (570mm) C C: 24.43" (620mm) Net Weight: 231.53 Lbs (105Kg) A B A B Blower Module GCSBLM014 Return Air Box Module GCSAR048060 Net Cabinet C Dimensions: A: 24.81" (630mm) Net Cabinet C Dimensions: A: 24.81" (630mm) B: 22.43" (570mm) B: 22.43" (570mm) A C: 19.12" (485mm) B A C: 14.56" (370mm) B Net Weight: Net Weight: 79.38 Lbs (36Kg) 36.38 Lbs (16.5Kg) GeoCool No-Vac Pre-Charged Line Sets The pre-charged, GeoCool No-Vac Line Sets, designed specifically for the Vertical Upflow A with or without Return Air Box and the Vertical Downflow allow for easy and fast installation. A GCNV-VU00-3834 Dimensions (LxW): 39.195" x 12.55" (995.53 x 319mm) Net Weight: 5.8 Lbs (2637g) B GCNV-VUAB-3834 Dimensions (LxW): 53.131" x 12.55" (1349.53 x 319mm) Net Weight: 6.48 Lbs (29420g) C B C GCNV-VD00-3834 Dimensions (LxW): 57.695" x 12.55" (1465.53 x 319mm) Net Weight: 6.7 Lbs (3040g)Adobe PDF Library 17.0 Adobe InDesign 18.4 (Macintosh)