75903RAN.001A1
ANT
5-75903RAN.001A1 - RF Exp FCC
Pietro Fiorentini Spa SSMICON250 Ultrasonic gas meter 2BB84-SSMICON250 2BB84SSMICON250 ssmicon250
Not Your Device? Search For Manuals or Datasheets below:
File Info : application/pdf, 10 Pages, 300.12KB
Document DEVICE REPORTGetApplicationAttachment.html?id=8365418DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Test report No: NIE: 75903RAN.001A1 Assessment report RF EXPOSURE REPORT ACCORDING TO FCC 47 CFR Part 2.1091; FCC 47 CFR Part 1.1307 FCC 47 CFR Part 1.1310 (*) Identification of item under evaluation Ultrasonic gas meter (*) Trademark Pietro Fiorentini S.p.a (*) Model and /or type reference SSM-iCON250-U7-NTC-004 (*) Other identification of the product (*) Features FCC ID: 2BB84-SSMICON250 IC: 31434-SSMICON250 HW version: 2.0 SW version: 1.0 Bluetooth LE (*) Manufacturer Test method requested, standard Pietro Fiorentini S.p.a Via Enrico Fermi 8/10, 36057 Arcugnano (VI) - ITALY FCC 47 CFR Part 2.1091 Radiofrequency radiation exposure evaluation: mobile devices. FCC 47 CFR Part 1.1307: Actions that may have a significant environmental effect, for which Environmental Assessments (EAs) must be prepared. FCC 47 CFR Part 1.1310: Radiofrequency radiation exposure limits. Summary IN COMPLIANCE Approved by (name / position & signature) Date of issue Manuel García Antennas Laboratory Technical Responsible 74862741H 74862741H MANUEL MANUEL GARCÍA GARCÍA (C:A29507456) 2024.11.28 11:45:37 (C:A29507456) +01'00' 2024-11-28 Report template No FAN36_02 (*) "Data provided by the client" Report No: (NIE) 75903RAN.001A1 2024-11-28 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Index Competences and guarantees ....................................................................................................3 General conditions ......................................................................................................................3 Data provided by the client..........................................................................................................3 Identification of the client.............................................................................................................3 Document history ........................................................................................................................3 Appendix A: FCC RF Exposure assessment result .....................................................................4 General description of the device under evaluation ................................................................5 Evaluation Results..................................................................................................................6 Appendix B: FCC RF Exposure information ................................................................................7 RF Exposure determination of exemption...............................................................................8 RF Exposure evaluation .......................................................................................................10 Report No: (NIE) 75903RAN.001A1 Page 2 of 10 2024-11-28 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Competences and guarantees In order to assure the traceability to other national and international laboratories, DEKRA Testing and Certification, S.A.U. has a calibration and maintenance program for its measurement equipment. DEKRA Testing and Certification, S.A.U. guarantees the reliability of the data presented in this report, which is the result of the measurements and the tests performed to the item under test on the date and under the conditions stated on the report and, it is based on the knowledge and technical facilities available at DEKRA Testing and Certification, S.A.U. at the time of performance of the test. DEKRA Testing and Certification, S.A.U. is liable to the client for the maintenance of the confidentiality of all information related to the item under test and the results of the test. The results presented in this Assessment Report apply only to the particular item under test established in this document. IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means, except in full, without the previous written permission of DEKRA Testing and Certification, S.A.U. General conditions 1. This report is only referred to the item that has undergone the assessment. 2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies or competent Authorities. 3. This document is only valid if complete; no partial reproduction can be made without previous written permission of DEKRA Testing and Certification, S.A.U. 4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous written permission of DEKRA Testing and Certification, S.A.U. and the Accreditation Bodies Data provided by the client The following data has been provided by the client: 1. Information relating to the description of the sample ("Identification of the item under evaluation", "Trademark", "Model and/or type reference", "General description of the device", "Other identification of the product"). 2. Maximum output power, maximum antenna gain and use distance information. 3. The device under evaluation consists of an Ultrasonic gas meter for residential and light industrial environment; local communication by BLE interface. DEKRA Testing and Certification S.A.U. declines any responsibility with respect to the information provided by the client and that may affect the validity of results. Identification of the client Pietro Fiorentini S.p.a Via Enrico Fermi 8/10, 36057 Arcugnano (VI) - ITALY Document history Report number 75903RAN.001 75903RAN.001A1 Date 2023-11-28 2024-11-28 Description First release Date updated to submit to FCC. Updated reference of RF test report. This modified test report cancels and replaces test report 75903RAN.001. Report No: (NIE) 75903RAN.001A1 Page 3 of 10 2024-11-28 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Appendix A: FCC RF Exposure assessment result Report No: (NIE) 75903RAN.001A1 Page 4 of 10 2024-11-28 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 General description of the device under evaluation Table 1 shows information used for the RF Evaluation, taking into account the following declared specifications for the device: Description and technologies: the device under evaluation consists of an Ultrasonic gas meter for residential and light industrial environment; local communication by BTLE interface. Evaluation Distance: according to the manufacturer, during its normal use, the separation distance between the radiating structures of the device and nearby users will be greater 20 cm. In order to perform the assessment a conservative evaluation distance of 20 cm has been used. Maximum output power values: - Values corresponding to BTLE conducted output power have been measured and stated into DEKRA Testing and Certification, S.A.U. test report num. 76874RRF.001A1. Antennas: the device supports one antenna for BTLE transmitting technology: - Value corresponding to antenna gain has been declared by the device manufacturer and stated into DEKRA Testing and Certification, S.A.U. test report num. 76874RRF.001A1. The following table shows the information provided above: Technology / Operating Mode Band Bluetooth LE 1Mb ISM Bluetooth LE 2Mb ISM Frequency under evaluation (MHz) 2400 - 2480 2400 - 2480 Maximum Conducted Output Power (dBm) Antenna peak gain (dBi) Maximum E.R.P. (dBm) Maximum E.R.P. (mW) Maximum E.I.R.P. (dBm) 0.75 -5.00 -6.40 0.23 -4.25 0.83 -5.00 -6.32 0.23 -4.17 Table 1: Equipment specifications Maximum E.I.R.P. (mW) 0.38 0.38 Report No: (NIE) 75903RAN.001A1 Page 5 of 10 2024-11-28 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Evaluation Results RF Exposure Exemption evaluation: Technology / Operating Mode Band Frequency under evaluation (MHz) Distance (cm) Maximum §1.1307(b)(3).i.(C) Verdict for E.R.P. Exposure Limit exemption § (mW) (mW) 1.1307(b)(3).i Bluetooth LE 1Mb ISM 2400 - 2480 20.00 0.23 Bluetooth LE 2Mb ISM 2400 - 2480 20.00 0.23 768.00 768.00 Pass Pass Table 2: FCC Exemption Evaluation Results The computed value(s) are below the exemption limit(s), so these modes meet the requirements stated in FCC 47 CFR Part 1.1307. Report No: (NIE) 75903RAN.001A1 Page 6 of 10 2024-11-28 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 Appendix B: FCC RF Exposure information Report No: (NIE) 75903RAN.001A1 Page 7 of 10 2024-11-28 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 RF Exposure determination of exemption According to FCC 47 CFR §1.1307 (b)(3) Determination of exemption: (i) For single RF sources (i.e., any single fixed RF source, mobile device, or portable device, as defined in paragraph (b)(2), a single RF source is exempt if: (A) The available maximum time-averaged power is no more than 1 mW, regardless of separation distance. This exemption may not be used in conjunction with other exemption criteria other than those in paragraph (b)(3)(ii)(A) of this section. Medical implant devices may only use this exemption and that in paragraph (b)(3)(ii)(A); (B) Or the available maximum time-averaged power or effective radiated power (ERP), whichever is greater, is less than or equal to the threshold Pth (mW) described in the following formula. This method shall only be used at separation distances (cm) from 0.5 centimeters to 40 centimeters and at frequencies from 0.3 GHz to 6 GHz (inclusive). Pth is given by: (C) Or using Table 1 and the minimum separation distance (R in meters) from the body of a nearby person for the frequency (f in MHz) at which the source operates, the ERP (watts) is no more than the calculated value prescribed for that frequency. For the exemption in Table 1 to apply, R must be at least /2, where is the free-space operating wavelength in meters. If the ERP of a single RF source is not easily obtained, then the available maximum time-averaged power may be used in lieu of ERP if the physical dimensions of the radiating structure(s) do not exceed the electrical length of /4 or if the antenna gain is less than that of a half-wave dipole (1.64 linear value). Report No: (NIE) 75903RAN.001A1 Page 8 of 10 2024-11-28 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 (ii) For multiple RF sources: Multiple RF sources are exempt if: (A) The available maximum time-averaged power of each source is no more than 1 mW and there is a separation distance of two centimeters between any portion of a radiating structure operating and the nearest portion of any other radiating structure in the same device, except if the sum of multiple sources is less than 1 mW during the time-averaging period, in which case they may be treated as a single source (separation is not required). This exemption may not be used in conjunction with other exemption criteria other than those is paragraph (b)(3)(i)(A) of this section. Medical implant devices may only use this exemption and that in paragraph (b)(3)(i)(A). (B) in the case of fixed RF sources operating in the same time-averaging period, or of multiple mobile or portable RF sources within a device operating in the same time averaging period, if the sum of the fractional contributions to the applicable thresholds is less than or equal to 1 as indicated in the following equation. Where: a = number of fixed, mobile, or portable RF sources claiming exemption using paragraph (b)(3)(i)(B) of this section for Pth, including existing exempt transmitters and those being added. b = number of fixed, mobile, or portable RF sources claiming exemption using paragraph (b)(3)(i)(C) of this section for Threshold ERP, including existing exempt transmitters and those being added. c = number of existing fixed, mobile, or portable RF sources with known evaluation for the specified minimum distance including existing evaluated transmitters. Pi = the available maximum time-averaged power or the ERP, whichever is greater, for fixed, mobile, or portable RF source i at a distance between 0.5 cm and 40 cm (inclusive). Pth,i = the exemption threshold power (Pth) according to paragraph (b)(3)(i)(B) of this section for fixed, mobile, or portable RF source i. ERPj = the ERP of fixed, mobile, or portable RF source j. ERPth,j = exemption threshold ERP for fixed, mobile, or portable RF source j, at a distance of at least /2 according to the applicable formula of paragraph (b)(3)(i)(C) of this section. Evaluated,k = the maximum reported SAR or MPE of fixed, mobile, or portable RF source k either in the device or at the transmitter site from an existing evaluation at the location of exposure. Exposure Limit,k = either the general population/uncontrolled maximum permissible exposure (MPE) or specific absorption rate (SAR) limit for each fixed, mobile, or portable RF source k, as applicable from §1.1310 of this chapter. The available maximum time-averaged power or effective radiated power (ERP), can be calculated using the following formula to assess compliance with the Exemption Limits: PE.I.R.P. = PT + GT - LC Where: PT= transmitter time-averaged output power (including Duty Cycle and tune-up tolerance, if applicable) GT= gain of the transmitting antenna LC = signal attenuation in the connecting cable between the transmitter and the antenna if applicable PE.R.P. = PE.I.R.P. 2.15 dB Report No: (NIE) 75903RAN.001A1 Page 9 of 10 2024-11-28 DEKRA Testing and Certification, S.A.U. Parque Tecnológico de Andalucía, c/ Severo Ochoa nº 2 · 29590 Campanillas · Málaga · España C.I.F. A29 507 456 RF Exposure evaluation Limits for Maximum Permissible Exposure (MPE) for RF sources are defined in FCC 47 CFR "§1.1310 Radiation Exposure limits, paragraph (e)": Each supported transmission technology will be evaluated to determine if it is in compliance with limits for Maximum Permissible Exposure (MPE) to radiofrequency electromagnetic fields. In order to perform the assessment, the following equations have been used for the calculations; these equations are accurate in the far-field of an antenna and will over-predict power density in the near field, where they could be used for making a "worst-case" or conservative prediction: Power density: S[mW / cm2 ] = PE.I.R.P.[mW ] 4R[cm]2 Where: S = power density PE.I.R.P. = Equivalent isotropically radiated power R = distance to the center of radiation of the antenna (evaluation distance) PE.I.R.P. = PT + GT - LC Where: PT= transmitter time-averaged output power (including Duty Cycle and tune-up tolerance, if applicable) GT= gain of the transmitting antenna LC = signal attenuation in the connecting cable between the transmitter and the antenna if applicable Report No: (NIE) 75903RAN.001A1 Page 10 of 10 2024-11-28
Related FCC IDs:
- 2BB84-SSMICON250 - Pietro Fiorentini Spa Ultrasonic gas meter [-SSMICON250] Microsoft Word 2019