EMC Test

GSM Lab

MPE

ZHEJIANG UNIVIEW TECHNOLOGIES CO LTD 0235CAKG IP Camera 2AL8S-0235CAKG 2AL8S0235CAKG 0235cakg

PDF Viewing Options

Not Your Device? Search For Manuals or Datasheets below:


File Info : application/pdf, 12 Pages, 424.35KB

Document DEVICE REPORTGetApplicationAttachment.html?id=8201077
Report No.: KSCR250300035402

Page:

1 of 12

1 Cover Page

RF Exposure Evaluation Report

Application No.:

KSCR2503000354AT

FCC ID:

2AL8S-0235CAKG

Applicant: Address of Applicant: Manufacturer: Address of Manufacturer: Factory: Address of Factory: Equipment Under Test (EUT): EUT Name:
Model No.:
Standard(s) : Date of Receipt: Date of Test: Date of Issue:

Zhejiang Uniview Technologies Co., Ltd. No. 369, Xietong Road, Xixing Sub-district, Binjiang District, Hangzhou City, 310051, Zhejiang Province, China Zhejiang Uniview Technologies Co., Ltd.
No. 369, Xietong Road, Xixing Sub-district, Binjiang District, Hangzhou City, 310051, Zhejiang Province, China Zhejiang Uniview Systems Technology Co., Ltd.
No.1277 South Qingfeng South Road, Tongxiang City, Jiaxing City, Zhejiang Province, China
IP Camera
Uho-P2C-M4F4, Uho-P2C-xxxxxxxx-yyyyyyyy-zzzz("x"can be 0-9,AZ,a-z or blank,denoting difference in interface,"y"can be 0-9,A-Z,a-z or blank,denoting performance difference,"z"can be 0-9,A-Z,a-z or blank,denoting target regional,"-" is option) FCC Rules 47 CFR §2.1091 KDB 447498 D04 interim General RF Exposure Guidance v01 2025-03-04 2025-03-05 to 2025-03-24 2025-03-25

Test Result:

Pass*

* In the configuration tested, the EUT complied with the standards specified above.

CCSEM-TRF-001 Rev. 03 Dec 18, 2024

Report No.: KSCR250300035402

Page:

2 of 12

Version 00

Description Original

Revision Record Date
2025-03-25

Remark /

Authorized for issue by: Tested By

Tommie_Tang/Project Engineer

Approved By

Terry Hou /Reviewer

CCSEM-TRF-001 Rev. 03 Dec 18, 2024

Report No.: KSCR250300035402

Page:

3 of 12

2 Contents
Page 1 Cover Page ........................................................................................................................................ 1 2 Contents ............................................................................................................................................ 3 3 General Information .......................................................................................................................... 4
3.1 General Description of E.U.T. .................................................................................................... 4 3.2 Technical Specifications............................................................................................................. 4 3.3 Separation Distance ................................................................................................................... 5 3.4 Test Location.............................................................................................................................. 6 3.5 Test Facility ................................................................................................................................ 6 4 RF Exposure Test Exemptions ........................................................................................................ 7 4.1 FCC RF Exposure Test Exemptions for single RF sources....................................................... 7 4.2 RF Exposure Test Exemptions for Simultaneous Transmission................................................ 9 5 Asurement and Calculation ........................................................................................................... 11 5.1 Maximum transmit power ......................................................................................................... 11 5.2 RF Exposure Calculation ......................................................................................................... 12

CCSEM-TRF-001 Rev. 03 Dec 18, 2024

Report No.: KSCR250300035402

Page:

4 of 12

3 General Information
3.1 General Description of E.U.T.

DC 12V,1A by adapter

Power supply:

Adapter Model: DCT24W120150US-A3 Input: 100-240V, 50/60Hz, 0.7A max.

Output: 12.0V, 1.5A

3.2 Technical Specifications

2.4GHz WiFi

Operation Frequency:

802.11b/g/n(HT20)/ax(HE20): 2412MHz to 2462MHz; 802.11n(HT40)/ax(HE40): 2422MHz to 2452MHz

802.11b: DSSS (CCK, DQPSK, DBPSK),

Modulation Type:

802.11g/n: OFDM (BPSK, QPSK, 16QAM, 64QAM),

802.11ax: OFDMA (BPSK, QPSK, 16QAM, 64QAM, 256QAM)

Number of Channels: 802.11b/g/n(HT20)/ax(HE20):11;802.11n(HT40)/ax(HE40):7

Channel Spacing:

5MHz

Antenna Type:

FPC Antenna

Antenna Gain:

4.59dBi (Provided by the manufacturer)

CCSEM-TRF-001 Rev. 03 Dec 18, 2024

Report No.: KSCR250300035402

Page:

5 of 12

3.3 Separation Distance
Separation distance between the antenna to person (R): 20cm
Remark: This minimum test separation distance is determined by the smallest distance from the antenna and radiating structures or outer surface of the device, according to the host form factor, exposure conditions and platform requirements, to any part of the body or extremity of a user or bystander. R has been stated in user manual.

CCSEM-TRF-001 Rev. 03 Dec 18, 2024

Report No.: KSCR250300035402

Page:

6 of 12

3.4 Test Location
All tests were performed at:
Compliance Certification Services (Kunshan) Inc.
No.10 Weiye Rd, Innovation park, Eco&Tec, Development Zone, Kunshan City, Jiangsu, China.
Tel: +86 512 5735 5888 Fax: +86 512 5737 0818
No tests were sub-contracted. Note: 1.SGS is not responsible for wrong test results due to incorrect information (e.g. max. clock frequency, highest internal frequency, antenna gain, cable loss, etc ) is provided by the applicant. (if applicable). 2.SGS is not responsible for the authenticity, integrity and the validity of the conclusion based on results of the data provided by applicant. (if applicable). 3. Sample source: sent by customer.
3.5 Test Facility
The test facility is recognized, certified, or accredited by the following organizations: · A2LA Compliance Certification Services (Kunshan) Inc. is accredited by the American Association for Laboratory Accreditation (A2LA). Certificate No. 2541.01. · FCC Compliance Certification Services (Kunshan) Inc. has been recognized as an accredited testing laboratory. Designation Number: CN1172. · ISED Compliance Certification Services (Kunshan) Inc. has been recognized by Innovation, Science and Economic Development Canada (ISED) as an accredited testing laboratory. Company Number: 2324E · VCCI The 3m and 10m Semi-anechoic chamber and Shielded Room of Compliance Certification Services (Kunshan) Inc. has been registered in accordance with the Regulations for Voluntary Control Measures with Registration No.: R-20134, R-11600, C-11707, T-11499, G-10216 respectively.

CCSEM-TRF-001 Rev. 03 Dec 18, 2024

Report No.: KSCR250300035402

Page:

7 of 12

4 RF Exposure Test Exemptions
Test exemptions apply for devices used in general population/uncontrolled exposure environments, according to the SAR-based, or MPE-based exemption thresholds.
4.1 FCC RF Exposure Test Exemptions for single RF sources
4.1.1 Blanket 1 mW Blanket Exemption The 1 mW Blanket Exemption of §1.1307(b)(3)(i)(A) applies for single fixed, mobile, and portable RF sources with available maximum time-averaged power of no more than 1 mW, regardless of separation distance. The 1-mW blanket exemption applies at separation distances less than 0.5 cm, including where there is no separation. This exemption shall not be used in conjunction with other exemption criteria other than those for multiple RF sources in paragraph §1.1307(b)(3)(ii)(A). The 1-mW exemption is independent of service type and covers the full range of 100 kHz to 100 GHz, but it shall not be used in conjunction with other exemption criteria or in devices with higher-power transmitters operating in the same time-averaging period. Exposure from such higher-power transmitters would invalidate the underlying assumption that exposure from the lower-power transmitter is the only contributor to SAR in the relevant volume of tissue. Medical implant devices may only use this exemption and that in paragraph (b)(3)(ii)(A);
4.1.2 MPE-based Exemption General frequency and separation-distance dependent MPE-based effective radiated power (ERP) thresholds are in Table B.1 [Table 1 of §1.1307(b)(1)(i)(C)] to support an exemption from further evaluation from 300 kHz through 100 GHz. The minimum separation distance (R in meters) from the body of a nearby person for the frequency (f in MHz) at which the source operates, the ERP (watts) is no more than the calculated value prescribed for that frequency. For the exemption in Table 1 to apply, R must be at least /2, where  is the free-space operating wavelength in meters. If the ERP of a single RF source is not easily obtained, then the available maximum time-averaged power may be used in lieu of ERP if the physical dimensions of the radiating structure(s) do not exceed the electrical length of /4 or if the antenna gain is less than that of a half-wave dipole (1.64 linear value).

CCSEM-TRF-001 Rev. 03 Dec 18, 2024

Report No.: KSCR250300035402

Page:

8 of 12

Table B.1--Thresholds For Single RF Sources Subject to Routine Environmental Evaluation

RF Source Frequency

Minimum Distance

fL MHz

fH MHz

L / 2

H / 2

0.3

­

1.34

159 m

­

35.6 m

1.34

­

30

35.6 m

­

1.6 m

30

­

300

1.6 m

­

159 mm

300

­

1,500

159 mm

­

31.8 mm

1,500

­

100,000

31.8 mm

­

0.5 mm

Subscripts L and H are low and high;  is wavelength.

R:Separation distance between the antenna to person

Threshold ERP W
1,920 R² 3,450 R²/f ²
3.83 R² 0.0128 R²f
19.2R²

The table applies to any RF source (i.e. single fixed, mobile, and portable transmitters) and specifies power and distance criteria for each of the five frequency ranges used for the MPE limits. These criteria apply at separation distances from any part of the radiating structure of at least /2. The thresholds are based on the general population MPE limits with a single perfect reflection, outside of the reactive nearfield, and in the main beam of the radiator.

Frequency range 1500~100000MHz

Limit calculation

Frequency(MHz) /2(m)

2462

0.0194

R(m) Threshold ERP(W)

0.2000

0.768

4.1.3 SAR-based Exemption SAR-based thresholds are derived based on frequency, power, and separation distance of the RF source. The formula defines the thresholds in general for either available maximum time-averaged power or maximum time-averaged ERP, whichever is greater. If the ERP of a device is not easily determined, such as for a portable device with a small form factor, the applicant may use the available maximum time-averaged power exclusively if the device antenna or radiating structure does not exceed an electrical length of /4. As for devices with antennas of length greater than /4 where the gain is not well defined, but always less than that of a half-wave dipole (length /2), the available maximum time-averaged power generated by the device may be used in place of the maximum time-averaged ERP, where that value is not known. The separation distance is the smallest distance from any part of the antenna or radiating structure for all persons, during operation at the applicable ERP. In the case of mobile or portable devices, the separation distance is from the outer housing of the device where it is closest to the antenna. The SAR-based exemption formula of §1.1307(b)(3)(i)(B), repeated here as Formula (B.2), applies for single fixed, mobile, and portable RF sources with available maximum time-averaged power or effective radiated power (ERP), whichever is greater, of less than or equal to the threshold Pth (mW). This method shall only be used at separation distances from 0.5cm to 40cm and at frequencies from 0.3 GHz to 6 GHz (inclusive). Pth is given by Formula (B.2).

CCSEM-TRF-001 Rev. 03 Dec 18, 2024

Report No.: KSCR250300035402

Page:

9 of 12

where

and f is in GHz, d is the separation distance (cm), and ERP20cm is per Formula (B.1).

Frequency range(GHz) 0.3~1.5 1.5~6

Limit calculation

Frequency(GHz) X

0.45

1.011

2.462

1.903

d(cm) 1 20

Pth (mW) 44.373 3060.000

4.2 RF Exposure Test Exemptions for Simultaneous Transmission
The available maximum time-averaged power of each source is no more than 1 mW and there is a separation distance of two centimeters between any portion of a radiating structure operating and the nearest portion of any other radiating structure in the same device, except if the sum of multiple sources is less than 1 mW during the time-averaging period, in which case they may be treated as a single source (separation is not required). This exemption may not be used in conjunction with other exemption criteria other than those is paragraph (b)(3)(i)(A) of this section. Medical implant devices may only use this exemption and that in paragraph (b)(3)(i)(A). Either SAR-based or MPE-based exemption may be considered for test exemption for fixed, mobile, or portable device exposure conditions; therefore, the contributions from each exemption in conjunction with the measured SAR (Evaluatedk term) shall be used to determine exemption for simultaneous transmission. In the case of fixed RF sources operating in the same time-averaging period, or of multiple mobile or portable RF sources within a device operating in the same time averaging period, if the sum of the fractional contributions to the applicable thresholds is less than or equal to 1 as indicated in the following equation.

Where: a = number of fixed, mobile, or portable RF sources claiming exemption using paragraph (b)(3)(i)(B) of this section for Pth, including existing exempt transmitters and those being added. b = number of fixed, mobile, or portable RF sources claiming exemption using paragraph (b)(3)(i)(C) of this section for Threshold ERP, including existing exempt transmitters and those being added.
CCSEM-TRF-001 Rev. 03 Dec 18, 2024

Report No.: KSCR250300035402

Page:

10 of 12

c = number of existing fixed, mobile, or portable RF sources with known evaluation for the specified minimum distance including existing evaluated transmitters. Pi = the available maximum time-averaged power or the ERP, whichever is greater, for fixed, mobile, or portable RF source i at a distance between 0.5 cm and 40 cm (inclusive). Pth,i = the exemption threshold power (Pth) according to paragraph (b)(3)(i)(B) of this section for fixed, mobile, or portable RF source i. ERPj = the ERP of fixed, mobile, or portable RF source j. ERPth,j = exemption threshold ERP for fixed, mobile, or portable RF source j, at a distance of at least  /2 according to the applicable formula of paragraph (b)(3)(i)(C) of this section. Evaluatedk = the maximum reported SAR or MPE of fixed, mobile, or portable RF source k either in the device or at the transmitter site from an existing evaluation at the location of exposure. Exposure Limitk = either the general population/uncontrolled maximum permissible exposure (MPE) or specific absorption rate (SAR) limit for each fixed, mobile, or portable RF source k, as applicable from § 1.1310 of this chapter.

CCSEM-TRF-001 Rev. 03 Dec 18, 2024

Report No.: KSCR250300035402

Page:

11 of 12

5 Asurement and Calculation
5.1 Maximum transmit power
The Power Data is based on the RF Test Report KSCR250300035401

Test Mode 11B SISO 11B SISO 11B SISO 11G SISO 11G SISO 11G SISO HT20 HT20 HT20 HT40 HT40 HT40 HE20 HE20 HE20 HE40 HE40 HE40

Test Channel
2412 2437 2462 2412 2437 2462 2412 2437 2462 2422 2437 2452 2412 2437 2462 2422 2437 2452

Ant
Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1 Ant1

Power [dBm] 9.89 9.63 9.48 10.37 9.78 9.18 10.08 9.50 8.97 11.41 11.03 10.64 9.76 9.25 8.59 11.22 10.78 10.33

Power [mW] 9.75 9.18 8.87 10.89 9.51 8.28 10.19 8.91 7.89 13.84 12.68 11.59 9.46 8.41 7.23 13.24 11.97 10.79

CCSEM-TRF-001 Rev. 03 Dec 18, 2024

Report No.: KSCR250300035402

Page:

12 of 12

5.2 RF Exposure Calculation
For single RF source : Evaluation method
Blanket 1 mW Blanket Exemption MPE-based Exemption(ERP)
SAR-based Exemption(Pth)

Separation distance between the antenna to person (R)
Regardless of separation distance
R ( /2 )
0.5cm<R<40cm

Band
WLAN 2.4GHz

Frequency 2412-2462

Max power Ant Gain

(dBm)

(dBi)

11.41

4.59

So the MPE of collocated transmitter is compliant.

EIRP (dBm)
16

Max EIRP (mW)
39.81

Limit (mW)
3060

Distance R (cm)
20

--End of the Report--

CCSEM-TRF-001 Rev. 03 Dec 18, 2024



Related FCC IDs: